Amana Two-Stage, Variable Speed Gas Furnace (SS

Downloaded from www.rsandrews.com. Since 1968, RS Andrews has proudly served Atlanta's Heating, Air Conditioning & Plumbing Needs.
amV8/adV8
two-Stage, Variable SPeed
gaS furnace
Product SPecificationS
The Amana® brand AMV8/ADV8 two-stage, variable-speed
multi-position, gas furnaces provide exceptional indoor
comfort and quiet operation. With their two-stage gas valves
and variable-speed circulator blowers, these furnaces provide
comfort all season long.
Standard Features
•
•
•
•
•
•
•
•
80% afue
•
Heating inPut: 70,000–115,000 btu/H
•
•
•
•
Patented MillionAir™ stainless-steel, dualdiameter tubular heat exchanger with
Lifetime Limited Unit Replacement
Warranty* for as long as the original registered homeowner owns their home
Two-stage gas valve operates on two-stage or
single-stage thermostats
Efficient and quiet variable-speed circulator motor
gently ramps up or down according to heating or
cooling demand
SureStart™ Silicon Nitride igniter designed for long igniter life
Furnace control board with self-diagnostics, colorcoded low-voltage terminals, and provisions for electronic air cleaner and 120-volt or 24-volt humidifiers
Low constant fan allows homeowner to activate very low
speed to efficiently circulate air throughout the home. This
setting costs as little as a 100-watt light bulb to operate.
Quiet, two-speed induced draft blower
All models comply with California NOx emissions standards
Cabinet Features
Fully insulated, heavy-gauge steel cabinet with durable
baked-enamel finish
Designed for multi-position installation: upflow,
horizontal left or right
Removable bottom for side- or bottom-return applications
Convenient left or right connection for gas/electric service
Coil and furnace fit flush for most installations
Contents
* To receive the Lifetime Heat Exchanger Limited Warranty, Lifetime Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of
installation. Online registration is not required in California or Québec. Full warranty details available
at www.amana-hac.com.
SS-AMV8
Nomenclature .................................................................................................... 2
Product Specifications .................................................................................. 3
Dimensions.......................................................................................................... 4
Performance Data ........................................................................................... 6
Wiring Diagrams .......................................................................................... 14
Accessories .........................................................................................................16
www.amana-hac.com
Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas.
6/09
Supersedes5/08
Product Specifications
Nomenclature
A
M
V
8
70
3
B
X
A
1
2
3
4
5,6,7
8
9
10
11
Brand
A Amana® Brand
Revisions
A Initial Release
B 1st Revision
C 2nd Revision
Airflow Direction
C Downflow/Horizontal
D Dedicated Downflow
H High Airflow
K Dedicated Upflow
M Upflow/Horizontal
NOx
N Natural Gas
X Low NOx
Description
V Two-Stage/Variable-speed
H Two-Stage/Multi-speed
S Single-Stage/Multi-speed
A
B
C
D
AFUE
95 95%
9 90%+
8 80%
045: 45,000
070: 70,000
090: 90,000
2
MBTU/h
115: 115,000
140: 140,000
www.amana-hac.com
Cabinet Width
14”
17½”
21”
24½”
Maximum CFM @ 0.5” ESP
3 1,200
4 1,600
5 2,000
SS-AMV8
Product Specifications
Specifications
AMV8
0704BXB
AMV8
0905CXB
AMV8
1155CXB
ADV8
0703BXB
ADV8
0905CXB
ADV8
1155CXB
70,000
90,000
115,000
70,000
90,000
115,000
Natural Gas
57,000
74,000
93,000
57,400
73,600
92,000
LP Gas
49,000
64,000
82,000
49,252
64,246
85,961
52,500
67,500
86,000
52,500
67,500
86,000
Natural Gas
42,000
54,000
69,000
42,000
54,000
69,000
LP Gas
42,000
54,000
69,000
43,096
55,409
70,595
80
80
80
80
80
80
1.5 - 3.0
2.0 - 5.0
2.0 - 5.0
1.5 - 3.0
2.0 - 5.0
2.0 - 5.0
20 - 50
25 - 55
25 - 55
20 - 50
20 - 50
25 - 55
10” x 8”
10” x 10”
10” x 10”
10” x 8”
10” x 10”
10” x 10”
¾
¾
¾
½
¾
¾
Variable
Variable
Variable
Variable
Variable
Variable
Vent Diameter¹
4”
4”
4”
4”
4”
4”
No. of Burners
3
4
5
3
4
5
576
460
460
576
460
460
11.7
11.7
11.7
10.4
12.8
12.8
15
15
15
15
15
15
152
178
194
156
182
202
Heating Capacity
High Fire Input (BTU/h)¹
High Fire Output (BTU/h)¹ (below)
Low Fire Input (BTU/h)¹
Low Fire Output (BTU/h)¹ (below)
AFUE2
Available AC @ 0.5” ESP
Temperature Rise Range (° F)
Circulator Blower
Size (D x W)
Horsepower @ 1750 RPM
Speed
Disposable Filter Size (in2)
Electrical Data
Min. Circuit Ampacity³
Max. Overcurrent Device (amps)4
Ship Weight (lbs)
Natural Gas BTU/h. For altitudes above 2,000’, reduce input rating 4% for each 1,000’ above sea level.
DOE AFUE based upon Isolated Combustion System (ICS)
3
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
4
Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit
breakers of the same size as noted.
1
2
Notes
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
• Gas Service Connection ½” FPT
• Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all
existing local codes.
SS-AMV8
www.amana-hac.com
3
Product Specifications
AMV8 Dimensions
A L T . V E N T L O C A T IO N
4 7 /1 6 "
3 1 /4 "
1 5 /1 6 "
1 9 5 /8 "
A L T . V E N T
L O C A T IO N
3 1 /4 "
2 1 /1 6 "
1 5 /1 6 "
A
B
3 1 /8 "
8 "
9 5 /1 6 "
1 2 3 /1 6 "
A L T . G A S IN L E T
C
39”
A L T . H IG H
G A S L O C A T IO N
H IG H
V O L T A G E
2 7 1 /1 6 "
2 6 1 /2 "
V O L T A G E
IN L E T
1 4 3 /1 6 "
L O W
1 4 3 /1 6 "
A L T . L O W
V O L T A G E
V O L T A G E
1 3 /8 "
D
28”
Model
1 3 /8 "
W
D
H
A
B
AMV80704BXB
17½”
28”
39”
17½”
16”
AMV80905CXB
21”
28”
39”
21”
19½”
AMV81155CXB
21”
28”
39”
21”
19½”
Minimum Clearances to Combustible Materials
Sides
Rear
Front¹
1
0
3
Vent²
SW
B
6
1
Top
1
Approved for line contact in the horizontal position.
¹ 24” clearance for serviceability recommended.
² Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables outlined in the Installation Manual for additional venting requirements.
4
www.amana-hac.com
SS-AMV8
Product Specifications
ADV8
Dimensions IDENTIFICATION
COMPONENT
ADV8*****XA
A
B
19 5/8"
Low Voltage
39"
High Voltage
1 15/16"
4 7/16"
28"
CABINET SIZE
Model
A
ADV80703BXB
14”
ADV80905CXB
21”
B
ADV80703BX**
12½”
ADV80905CX**
19½”
ADV81155CXB
21”
ADV81155CX**
19½”
Alt. Gas Inlet
11 3/8"
8 5/8"
Gas Inlet
A
B
Non-Combustible
Floor base
17-1/2
16
SBT17
21
19-1/2
SBT21
21
19-1/2
SBT21
All dimensions are in inches.
Minimum Clearances to Combustible Materials
Sides
Rear
Front¹
1
0
3
Vent²
SW
B
6
1
Top
1
Notes
Approved for line contact in the horizontal position.
¹ 24” clearance for serviceability recommended.
² Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables
outlined in the Installation Manual for additional venting requirements.
6
SS-AMV8
www.amana-hac.com
5
Product Specifications
AMV8 Performance Data
High- or Single-Stage Cooling Speeds — AMV8
AMV80704BXB
Cooling
Speed
Tap
A
B
C
D
AMV80905CXB
Adjust
Tap
CFM @ .1” to
.8” W.C. ESP
Minus (-)
540
Normal
600
Plus (+)
660
Minus (-)
720
Normal
800
Cooling
Speed
Tap
A
B
AMV81155CXB
Adjust
Tap
CFM @ .1” to
.8” W.C. ESP
Minus (-)
720
Normal
800
Plus (+)
880
Minus (-)
990
Normal
1,100
Cooling
Speed
Tap
A
B
Adjust
Tap
CFM @ .1” to
.8” W.C. ESP
Minus (-)
720
Normal
800
Plus (+)
880
Minus (-)
990
Normal
1,100
Plus (+)
880
Plus (+)
1,210
Plus (+)
1,210
Minus (-)
990
Minus (-)
1,260
Minus (-)
1,260
Normal
1,100
Normal
1,400
Normal
1,400
C
C
Plus (+)
1,210
Plus (+)
1,540
Plus (+)
1,540
Minus (-)
1,260
Minus (-)
1,620
Minus (-)
1,620
Normal
1,400
Normal
1,800
Plus (+)
1,540
Plus (+)
1,980
D
D
Normal
1,800
Plus (+)
1,980
Low-Stage Cooling Speeds — AMV8
AMV80704BXB
Cooling
Speed
Tap
A
B
C
D
AMV80905CXB
Adjust
Tap
CFM @ .1” to
.8” W.C. ESP
Minus (-)
361†
Normal
390
Cooling
Speed
Tap
A
AMV81155CXB
Adjust
Tap
CFM @ .1” to
.8” W.C. ESP
Minus (-)
563†
Normal
563†
Cooling
Speed
Tap
A
Adjust
Tap
CFM @ .1” to
.8” W.C. ESP
Minus (-)
563†
Normal
563†
Plus (+)
429
Plus (+)
572
Plus (+)
572
Minus (-)
468
Minus (-)
644
Minus (-)
644
Normal
520
Normal
715
Normal
715
Plus (+)
572
Plus (+)
787
Plus (+)
787
Minus (-)
644
Minus (-)
819
Minus (-)
819
Normal
715
Plus (+)
787
Minus (-)
819
Normal
910
Plus (+)
1,001
B
C
D
Normal
910
Plus (+)
1,001
Minus (-)
1,053
Normal
1,170
Plus (+)
1,287
B
C
D
Normal
910
Plus (+)
1,001
Minus (-)
1,053
Normal
1,170
Plus (+)
1,287
* Motor CFM maximum
† Motor CFM minimum
Notes
• These charts are for furnaces installed at 0’ - 2,000’. At higher altitudes, a properly de-rated unit will have the same temperature rise at a
particular CFM, while the ESP at that CFM will be lower.
• THE INSTALLATION IS TO BE ADJUSTED TO OBTAIN A TEMPERATURE RISE WITHIN THE RANGE LISTED ON THE FURNACE NAMEPLATE.
• Propane gas installations will have a high-stage rise approximately 4° lower than shown in the tables.
6
www.amana-hac.com
SS-AMV8
Product Specifications
AMV8 Performance Data (cont.)
Cooling-Based Continuous Fan – AMV8
AMV80704BXB
Cooling
Speed
Tap
A
B
C
D
AMV80905CXB
Adjust
Tap
CFM @ .1” to
.8” W.C. ESP
Minus (-)
361†
Normal
361†
Plus (+)
Cooling
Speed
Tap
AMV81155CXB
Adjust
Tap
CFM @ .1” to
.8” W.C. ESP
Minus (-)
563†
Normal
563†
370
Plus (+)
Minus (-)
403
Normal
448
Plus (+)
Cooling
Speed
Tap
Adjust
Tap
CFM @ .1” to
.8” W.C. ESP
Minus (-)
563†
Normal
563†
563†
Plus (+)
563†
Minus (-)
563†
Minus (-)
563†
Normal
616
Normal
616
493
Plus (+)
678
Plus (+)
678
Minus (-)
554
Minus (-)
706
Minus (-)
706
Normal
616
Normal
784
Normal
784
Plus (+)
678
Plus (+)
862
Plus (+)
862
Minus (-)
706
Minus (-)
907
Minus (-)
907
Normal
784
Normal
1,008
Normal
1,008
Plus (+)
862
Plus (+)
1,109
Plus (+)
1,109
A
B
C
D
A
B
C
D
* Motor CFM maximum
† Motor CFM minimum
Notes:
• These charts are for furnaces installed at 0’ - 4,500’. At higher altitudes, a properly de-rated unit will have the same temperature rise at a
particular CFM, while the ESP at that CFM will be lower.
• THE INSTALLATION MUST BE ADJUSTED TO OBTAIN A TEMPERATURE RISE WITHIN THE RANGE LISTED ON THE FURNACE NAMEPLATE.
• Propane gas installations will have a high-stage rise approximately 4° lower than shown in the tables.
Auto-Comfort Mode
During Auto-Comfort mode, the furnace ramps up to 50% of the demand for half a minute. It then ramps
to 82% of the full cooling demand airflow and operates there for approximately 7½ minutes. The motor
then steps up to the full demand airflow. This mode spends a half minute at 50% airflow OFF delay.
SS-AMV8
www.amana-hac.com
7
Product Specifications
AMV8 Performance Data (cont.)
Heating Speeds
AMV80704BXB
(Rise Range: 20° - 50 °F)
AMV80905CXB
(Rise Range: 25° - 55°F)
Heating
Low Stage
Adjust Tap
Speed Tap
CFM ¹
High Stage
CFM ¹
Rise ˚F
Minus (-)
810
1,077
48
Normal
900
1,197
43
A
B
C
D
Heating
Speed Tap
A
Adjust
Tap
Low Stage
CFM ¹
High Stage
CFM ¹
Rise ˚F
Minus (-)
945
1,257
53
Normal
1,050
1,397
48
Plus(+)
990
1,317
39
Plus(+)
1,155
1,536
43
Minus (-)
900
1,197
43
Minus (-)
1,035
1,377
48
Normal
1,000
1,330
39
Normal
1,150
1,530
43
Plus(+)
1,100
1,463
35
Plus(+)
1,265
1,682
40
Minus (-)
990
1,317
39
Minus (-)
1,125
1,496
44
Normal
1,100
1,463
35
Normal
1,250
1,663
40
Plus(+)
1,210
1,609
32
Plus(+)
1,375
1,829
36
Minus (-)
1,215
1,616
41
Normal
1,350
1,796
37
Plus(+)
1,485
1,975
34
Minus (-)
1,080
1,436
36
Normal
1,200
1,596
32
Plus(+)
1,320
1650*
29
¹ @ .1” to .5” w.c. ESP
* Motor CFM maximum
B
C
D
† Motor CFM minimum
AMV81155CXB
(Rise Range: 25° - 55°F)
Heating
Low Stage
Adjust Tap
Speed Tap
CFM ¹
High Stage
CFM ¹
Rise ˚F
Minus (-)
1,170
1,556
55
Normal
1,300
1,729
49
Plus(+)
1,430
1,902
45
A
B
C
D
Minus (-)
1,215
1,616
53
Normal
1,350
1,796
47
Plus(+)
1,485
1,975
43
Minus (-)
1,260
1,676
51
Normal
1,400
1,862
46
Plus(+)
1,540
2000*
41
Minus (-)
1,373
1,825
47
Normal
1,525
2000*
42
Plus(+)
1,678
2000*
38
Notes
• These charts are for furnaces installed at 0’ - 4,500’. At higher altitudes, a properly de-rated unit will have the same temperature
rise at a particular CFM, while the ESP at that CFM will be lower.
• The installation must be adjusted to obtain a temperature rise
within the range listed on the furnace nameplate.
• Do not operate above .5” w.c. ESP in heating mode.
• Propane gas installations will have a high-stage rise approximately 4° lower than shown in the tables.
¹ @ .1” to .5” w.c. ESP
* Motor CFM maximum
† Motor CFM minimum
8
www.amana-hac.com
SS-AMV8
SS-AMV8
www.amana-hac.com
10
20
30
40
30
50
60
70
80
90
100
40
50
60
700
600 CFM
90
100
2000
2200
2400 CFM
1800
1600
1400
OUTPUT BTU/HR x 1000
80
1200
1100
1000
900
70
800
FORMULAS
110
120
130
140
BTU OUTPUT = CFM x 1.08 x RISE
BTU OUTPUT
RISE =
÷ CFM
1.08
BTU OUTPUT vs TEMPERATURE RISE CHART
150
Product Specifications
AMV8 Temperature Rise Chart
BLOWER PERFORMANCE SPECIFICATIONS
15
9
TEMPERATURE RISE
Product Specifications
ADV8 Performance Data
High- or Single-Stage Cooling Speeds
ADV80703BXB
Cooling
Speed Tap
A
B
C
D
ADV80905CXB
Adjust
Tap
CFM¹
Minus (-)
540
Cooling
Speed Tap
Adjust
Tap
CFM¹
Minus (-)
720
Cooling
Speed Tap
CFM¹
Minus (-)
765
Normal
600
Normal
800
Normal
850
660
Plus (+)
880
Plus (+)
935
Minus (-)
720
Minus (-)
990
Minus (-)
1,035
Normal
800
880
Minus (-)
900
Normal
1,000
Plus (+)
1,100
Minus (-)
1,080
Normal
1,200
Plus (+)
1,320
B
C
D
Normal
1,100
Plus (+)
1,210
Minus (-)
1,260
Normal
1,400
Plus (+)
1,540
Minus (-)
1,620
Normal
1,800
Plus (+)
1,980
A
Adjust
Tap
Plus (+)
Plus (+)
A
ADV81155CXB
B
C
D
Normal
1,150
Plus (+)
1,265
Minus (-)
1,305
Normal
1,450
Plus (+)
1,595
Minus (-)
1,665
Normal
1,850
Plus (+)
2000*
Low-Stage Cooling Speeds
ADV80703BXB
Cooling
Speed Tap
A
B
C
D
ADV80905CXB
Adjust
Tap
CFM¹
Minus (-)
351†
Normal
390
Plus (+)
429
Minus (-)
468
Normal
520
Plus (+)
572
Minus (-)
585
Normal
650
Plus (+)
715
Minus (-)
702
Normal
780
Plus (+)
858
Cooling
Speed Tap
A
B
C
D
ADV81155CXB
Adjust
Tap
CFM¹
Minus (-)
468
Normal
520
Plus (+)
572
Minus (-)
644
Normal
715
Plus (+)
787
Minus (-)
819
Normal
910
Plus (+)
1,001
Minus (-)
1,053
Normal
1,170
Plus (+)
1,287
Cooling
Speed Tap
A
B
C
D
Adjust
Tap
CFM¹
Minus (-)
563†
Normal
563†
Plus (+)
619
Minus (-)
673
Normal
748
Plus (+)
822
Minus (-)
848
Normal
943
Plus (+)
1,037
Minus (-)
1,082
Normal
1,203
Plus (+)
1,323
¹ @ .1” to .8” W.C. ESP
* Motor CFM maximum
† Motor CFM minimum
Notes
• These charts are for furnaces installed at 0’ - 4,500’. At higher altitudes, a properly de-rated unit will have the same temperature rise at a
particular CFM, while the ESP at that CFM will be lower.
• THE INSTALLATION MUST BE ADJUSTED TO OBTAIN A TEMPERATURE RISE WITHIN THE RANGE LISTED ON THE FURNACE NAMEPLATE.
• Propane gas installations will have a high-stage rise approximately 4° lower than shown in the tables.
10
www.amana-hac.com
SS-AMV8
Product Specifications
ADV8 Performance Data (cont.)
Cooling-Based Continuous Fan
ADV80703BXB
Cooling
Speed Tap
A
B
C
D
ADV80905CXB
Adjust
Tap
CFM¹
Minus (-)
302
Normal
336
Plus (+)
Cooling
Speed Tap
ADV81155CXB
Adjust
Tap
CFM¹
Minus (-)
403
Adjust
Tap
CFM¹
Minus (-)
563†
Normal
448
Normal
563†
370
Plus (+)
493
Plus (+)
563†
Minus (-)
403
Minus (-)
554
Minus (-)
580
Normal
448
Normal
616
Normal
644
Plus (+)
493
Plus (+)
678
Plus (+)
708
Minus (-)
504
Minus (-)
706
Minus (-)
731
Normal
560
Normal
784
Normal
812
Plus (+)
616
Plus (+)
862
Plus (+)
893
Minus (-)
605
Minus (-)
907
Minus (-)
932
Normal
672
Normal
1,008
Normal
1,036
Plus (+)
739
Plus (+)
1,109
Plus (+)
1,140
A
B
C
D
Cooling
Speed Tap
A
B
C
D
¹ @ .1” to .8” W.C. ESP
* Motor CFM maximum
† Motor CFM minimum
Notes:
• These charts are for furnaces installed at 0’ - 4,500. At higher altitudes, a properly de-rated unit will have the same temperature rise
at a particular CFM, while the ESP at that CFM will be lower.
• THE INSTALLATION MUST BE ADJUSTED TO OBTAIN A TEMPERATURE RISE WITHIN THE RANGE LISTED ON THE FURNACE NAMEPLATE.
• Propane gas installations will have a high-stage rise approximately 4° lower than shown in the tables.
SS-AMV8
www.amana-hac.com
11
Product Specifications
ADV8 Performance Data (cont.)
Heating Speeds
ADV80703BXB
(Rise Range: 20° - 50°F)
Heating
Speed Tap
A
B
C
D
ADV80905CXB
(Rise Range: 20° - 50°F)
Adjust Tap
Low-Stage
CFM¹
High-Stage
CFM¹
Rise
˚F
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
720
800
880
810
900
990
900
1,000
1,100
958
1,064
1,170
1,077
1,197
1,317
1,197
1,330
1,463
--49
44
48
43
39
43
39
35
Minus (-)
Normal
Plus(+)
990
1,100
1,210
1,317
1,463
1,609
39
35
32
Heating
Speed Tap
A
B
C
D
Adjust Tap
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Low-Stage
CFM¹
High-Stage
CFM¹
Rise
˚F
945
1,050
1,155
1,035
1,150
1,265
1,125
1,250
1,375
1,215
1,350
1,485
1,257
1,397
1,536
1,377
1,530
1,682
1,496
1,663
1,829
1,616
1,796
1,975
--48
43
48
43
40
44
40
36
41
37
34
¹ @ .1” to .5” w.c. ESP
* Motor CFM maximum
† Motor CFM minimum
ADV81155CXB
(Rise Range: 25° - 55°F)
Heating
Speed Tap
A
B
C
D
Adjust Tap
Low-Stage
CFM¹
High-Stage
CFM¹
Rise
˚F
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
1,215
1,350
1,485
1,260
1,400
1,540
1,305
1,450
1,595
1,418
1,575
1,733
1,616
1,796
1,975
1,676
1,862
2000*
1,736
1,929
2000*
1,885
2000*
2000*
52
47
43
51
46
41
49
44
40
45
40
37
Notes
• These charts are for furnaces installed at 0’- 4,500’. At higher
altitudes, a properly de-rated unit will have the same temperature rise at a particular CFM, while the ESP at that CFM will be
lower.
• The installation must be adjusted to obtain a temperature rise
within the range listed on the furnace nameplate.
• Do not operate above .5” w.c. ESP in heating mode.
• Propane gas installations will have a high-stage rise approximately 4° lower than shown in the tables.
¹ @ .1” to .5” w.c. ESP
* Motor CFM maximum
† Motor CFM minimum
12
www.amana-hac.com
SS-AMV8
SS-AMV8
www.amana-hac.com
10
20
30
40
50
60
70
30
80
90
100
40
50
60
700
600 CFM
90
100
2000
2200
2400 CFM
1800
1600
1400
OUTPUT BTU/HR x 1000
80
1200
1100
1000
900
70
800
FORMULAS
110
120
130
140
BTU OUTPUT = CFM x 1.08 x RISE
BTU OUTPUT
RISE =
÷ CFM
1.08
BTU OUTPUT vs TEMPERATURE RISE CHART
150
Product Specifications
ADV8
TemperaturePERFORMANCE
Rise Chart
BLOWER
SPECIFICATIONS
15
13
TEMPERATURE RISE
Wiring is subject to change. Always
refer to the wiring diagram on the
unit for the most up-to-date wiring
WARNING
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
Product Specifications
AMV8 Wiring Diagram
14
www.amana-hac.com
SS-AMV8
Product Specifications
ADV8 Wiring Diagram
BK 16 WIRE HARNESS
8
9
4
5
6
1
7
2
3
10
7
8
9
9
8
7
4
5
6
6
5
4
1
2
3
3
2
1
TO 115VAC/ 1
Ø /60 HZ POWER SUPPLY WITH
OVERCURRENT PROTECTION DEVICE
BK
BK
DOOR SWITCH
BR
L
WARNING:
DISCONNECT POWER
BEFORE SERVICING.
WIRING TO UNIT
MUST BE PROPERLY
POLARIZED AND
GROUNDED.
N
SEE
NOTE 5
DISCONNECT
BR
12
13
11
BR
11
14
12
TWIN/
DEHUM
W2
W1
R
G
B/C
Y
O
YLO
FUSE
RD
10
15
12
AUXILIARY
LIMIT CONTROL
BL
PU
DOOR
SWITCH
INDUCTOR COIL
90kBTU, 115 KBTU
MODELS ONLY
2
CIRCULATOR
BLOWER
3
5
LINE
XFMR
EAC
CIRC
HUM
HUM
XFMR
LINE
EAC
YL
INDOOR
AIR
CIRCULATOR
BLWR
BK
WH
4
DIAGNOSTIC
LED
GND
JUNCTION BOX
WH
1
NE UTRAL
HOT
24
VAC
RD
CONTROL
PANEL
BK
115
VAC
WH
JUNCTION BOX
LINE-N
GND
BL
LINE H
BK
INDUCTOR COIL
ON SOME MODELS
SEE
NOTE 5
TO 115 VAC/ 1/60HZ
POWER SUPPLY WITH
OVERCURRENT PROTECTION
DEVICE
HUM-H
FLAME SENSOR
WH
WH
RD
BK
2
BR
1
PU
YL
NO
YL
OR
C
LOW FIRE
PRESSURE SWITCH
BR
INDUCED
DRAFT
BLOWER
24
VAC.
HUM.
24V THERMOSTAT CONNECTIONS
BK
3
RD
WH
BR
W1
24 VAC
AUTO RESET
PRIMARY LIMIT
CONTROL
HLO (11)
MANUAL RESET ROLLOUT
LIMIT CONTROL
YLO
HL1 (6)
W2
Y
XFMR-N
40 VA
TRANSFORMER
TH (5)
TO
MICRO
G
24V HUMIDIFIER
RD
115 VAC
FUSE 3 A
C
PRIMARY
LIMIT CONTROL
BL
IGN-N
HOT SURFACE
IGNITER
XFMR-H
R
C
HUM-N
HUMIDIFIER
IGN-H
BURNER COMPARTMENT
NO
IND-N
ID
BLWR
IND LO
FP (3)
HI FIRE
PRESSURE SWITCH
EAC-N
ELECTRONIC
AIR CLEANER
IND HI
BLOWER COMPARTMENT
YL
LINE-N
EAC-H
24V HUM.
PS1 (12)
MVH (1)
C
NO
AUXILIARY LIMIT
CONTROL
MVL(7)
LOW FIRE
PRESSURE
SWITCH
PM
NO
C
PS2 (2)
HIGH FIRE
PRESSURE SWITCH
MVC (8)
BR
WH
GND (4)
BK
HI
3
2 STAGE
GAS VALVE
PU
INTEGRATED CONTROL MODULE
ROLL OUT LIMITS CONTROL
HOT
SURFACE
IGNITOR
ON = NORMAL OPERATION
11
FLASH =
22
33
FLASHES = LOW FIRE PRESSURE SWITCH STUCK CLOSED
FLASHES = LOW FIRE PRESSURE SWITCH STUCK OPEN
44
FLASHES = THERMAL PROTECTIVE DEVICE OPEN
65
88
FLASHES = FLAME SENSED WITH GAS VALVE DE-ENERGIZED
FLASHES = LOW FLAME SENSE SIGNAL
FLASHES = CHECK IGNITER OR IMPROPER GROUNDING
99
FLASHES = HIGH FIRE PRESSURE SWITCH STUCK OPEN
77
CCONTINUOUS
COLOR CODES:
YL YELLOW
OR ORANGE
PU PURPLE
GR GREEN
BK BLACK
SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED)
0140F00081P REV.0
SS-AMV8
FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
SWITCH (TEMP.)
IGNITER
SWITCH (PRESS.)
OVERCURRENT
PROT. DEVICE
FLASHES = 115 VOLT AC POWER REVERSED
PK PINK
BR BROWN
WH WHITE
BL BLUE
GY GRAY
RD RED
C
++ - USE NEC CLASS 2 WIRE
FLAME
SENSOR
0 STEADY
HI
GAS
VALVE
TR (9)
PM C
2
1
INTEGRATED CONTROL MODULE
WH
INTEGRATED CONTROL MODULE
BL
BK
BK
OR
YL
RD
GR
LINE-H
BK
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
24 V THERMOSTAT CONNECTIONS + +
16 PIN
PLUG
15
11
WARNING
24 VAC. HUM.
14
10
Wiring is subject to change. Always
refer to the wiring diagram on the
unit for the most up-to-date wiring
BR
13
NOTES:
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE
REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE
°C. USE COPPER CONDUCTORS ONLY.
RATING OF AT LEAST 105
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
5. USE COPPER CONDUCTORS ONLY
www.amana-hac.com
15
Product SPecificationS
acceSSorieS
MoDel
AMV8
AMV8
AMV8
ADV8
ADV8
ADV8
0704BXB 0905CXB 1155CXB 0703BXB 0905CXB 1155CXB
DesCription
LPM-03B
LP Conversion Kit (Gas Valve)
√
√
√
√
√
√
LPM-05
LP Conversion Kit (Springs & Orifice)
√
√
√
√
√
√
AFE18-60A
Fossil Fuel Kit (must be used in a dual-fuel
application with a compatible thermostat)
√
√
√
√
√
√
ASAS
Electronic Air Cleaners
(* = -10, -11, -12 or -18)
√
√
√
√
√
√
AMU
Media Air Cleaners
(* = 1620, 2020, 1625 or 2025)
√
√
√
√
√
√
tHermoStatS
A two-stage thermostat should be used with the AMV8 furnace. Two-stage thermostats control which firing rate is
used depending on the temperature difference between the set point and the room temperature. A properly used
two-stage thermostat and furnace will maintain a much tighter control of temperature than a conventional singlestage thermostat and furnace. Two-stage furnaces have “W1” and “W2” terminals. If the thermostat has “Y1” and “Y2”
cooling connections and a single-stage cooling system is used, connect “Y” on the furnace control to “Y1” on the
thermostat. The table below describes two-stage thermostats that have been configured for use with this furnace.
MoDel
two-stAge tHerMostAt DesCription
Color
1213411
Digital, Non-Programmable, 2-stage, 2 Heat/2 Cool
White
1213407
Digital, Programmable, 2-stage, 2 Heat/1 Gool
White
1213406*
Programmable, 3-stage, Manual or Automatic Changeover
Beige
* For use in dual-fuel applications with a heat pump in a fossil fuel application. It is not for use with the GMV8 as a sole
heating source.
Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing commitment to quality products may mean a change in specifications without notice. © 2009 • Goodman Company, L.P. • Houston, Texas • Printed in the USA.
16
www.amana-hac.com
SS-AMV8