UNIDEN PROGRAMMING CONTROL CODES FOR

UNIDEN PROGRAMMING CONTROL CODES
FOR USE WITH UNIDEN SCANNERS
End User License Agreement
UNIDEN AMERICA CORPORATION
NOTICE TO USER: THIS END USER LICENSE AGREEMENT (“EULA”) IS A
LEGAL AGREEMENT BETWEEN YOU AND UNIDEN. PLEASE READ THIS
CAREFULLY BEFORE USING THE UNIDEN CODE. BY CLICKING THE " I
AGREE TO THE TERMS OF THIS LICENSE AGREEMENT ", OR BY USING
ALL OR ANY PORTION OF THE UNIDEN CODE, YOU ARE CONFIRMING
YOUR ACCEPTANCE OF THE UNIDEN CODE AND ALL THE TERMS AND
CONDITIONS OF THIS AGREEMENT. IF YOU DO NOT AGREE, DO NOT
USE THE UNIDEN CODE. CLICK THE " I DO NOT AGREE TO THE TERMS
OF THIS LICENSE AGREEMENT " FOR THE INSTALLATION PROCESS TO
TERMINATE.
1. DEFINITIONS
(A)
“Uniden Code” means Uniden proprietary programming codes and
commands used to control Uniden’s scanner products.
(B)
"Use" or "Using" means to access, install, download, copy or otherwise
benefit from using the functionality of the Uniden Code.
(C)
"Computer" means an electronic device that accepts information in
digital or similar form and manipulates it for a specific result based on a
sequence of instructions.
(D)
"Uniden" means Uniden America Corporation, a Delaware corporation,
located at 4700 Amon Carter Boulevard, Fort Worth, Texas 76155, and
its licensors, if any.
2. UNIDEN CODE LICENSE GRANTS
(A)
You may utilize the Uniden Code on an “as is”, at-will, royalty-free,
personal, non-assignable, non-exclusive basis solely for the purpose of
creating software or firmware products intended to extend the
functionality of Uniden scanner products, or provide compatibility of
Uniden scanner products with a PC or other control devices.
(B)
You agree that the Uniden Code will not be used to create a competing
scanner product.
(C)
You agree not to use the Uniden Code functionality for purposes other
than to control one or more of the Uniden scanner models to which the
codes apply.
(D)
You acknowledge that the Uniden Code is provided “as-is” and that
Uniden has no obligation to provide any additional support in the use of
the Uniden Code beyond the disclosed documentation.
(E)
User acknowledges that, while reasonable efforts have been taken to
ensure accuracy in the supplied documentation, said documents have
been subjected to one or more translation stages that might have
resulted in unclear, inaccurate, or incomplete information and that
Uniden is under no obligation to correct or clarify supplied
documentation of the Uniden Code.
(F)
You acknowledge that the Uniden Code is the sole property of Uniden.
(G)
You agree that the Uniden Code, documentation thereof and the
related information provided by Uniden are confidential and proprietary
information of Uniden (collectively “Uniden Confidential Information”).
(H)
You agree to mark any software containing all or part of the Uniden
Code, and the written user materials accompanying units that
incorporate Uniden Code with notices indicating, “This product
contains Uniden proprietary and/or copyright control codes. Used with
permission.”
(I)
You agree that this EULA does not need to be signed for it to take
effect.
(J)
You agree to use the Uniden Code in its regular and proper manner.
(K)
You acknowledge that Uniden may update, modify or revise the Uniden
Code at any time and shall not be obligated to provide such updates,
modifications or revisions to you.
(L)
You acknowledge that the permission granted herein does not
constitute endorsement by Uniden of any software or firmware
products you may create in accordance with the purpose stated in
section A herein; and you are solely responsible for the configuration of
said software or firmware and/or any service matters relating to said
software or firmware and/or any Uniden Code used with said software
or firmware.
(M)
This license is personal to you and you may make copies of the
Uniden Code only for your personal use.
(N)
You agree that Uniden may audit your use of the Uniden Code for
compliance with these terms at any time.
(O)
You agree and represent that any products you create which
incorporate the Uniden Code are in compliance with all applicable
laws.
(P)
You shall defend, indemnify and hold harmless Uniden, its subsidiaries
and affiliates, and all agents, employees, officers and directors of
Uniden, its subsidiaries and affiliates, from all expenses, losses, costs,
damages or liability (including reasonable attorneys’ fees and court
costs and expenses) arising out of or in connection with any claim or
action in connection with the use of any products you create which
incorporate the Uniden Code.
3. LICENSE RESTRICTIONS
(A) Other than as set forth in Section 2 of this EULA, you may not make or
distribute copies of the Uniden Code, or electronically transfer the
Uniden Code from one computer to another or over a network.
(B) You may not alter, merge, modify, adapt or translate the Uniden Code, or
decompile, reverse engineer, disassemble, or otherwise reduce the
Uniden Code to a human-perceivable form.
(C) You may not sell, rent, lease, assign or sublicense the Uniden Code.
(D) You may not modify the Uniden Code or create derivative works based
upon the Uniden Code.
(E) You may not export the Uniden Code into any country prohibited by the
United States Export Administration Act and the regulations thereunder.
(F) In the event that you fail to comply with this EULA, Uniden may terminate
the license and you must destroy all copies of the Uniden Code (with all
other rights of both parties and all other provisions of this EULA surviving
any such termination).
4. OWNERSHIP
The foregoing license gives you limited license to use the Uniden Code. Uniden
retains all right, title and interest, including all copyright and intellectual property
rights, in and to, the Uniden Code or any derivative works, including but not
limited to the structure and organization of the Uniden Code, and all copies
thereof. All rights not specifically granted in this EULA, including Federal and
International Copyrights, are reserved by Uniden. Uniden reserves the right to
terminate this license at any time.
5. WARRANTY DISCLAIMER
(A) THE UNIDEN CODE IS PROVIDED TO YOU ON AN “AS-IS” BASIS.
UNIDEN PROVIDES NO TECHNICAL SUPPORT OR WARRANTIES
FOR THE UNIDEN CODE.
(B) UNIDEN AND ITS SUPPLIERS DISCLAIM ALL WARRANTIES AND
REPRESENTATIONS (EXPRESS OR IMPLIED WHETHER BY
STATUTE, COMMON LAW, CUSTOM, USAGE OR OTHERWISE)
INCLUDING THE WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. ALSO, THERE IS NO WARRANTY
OF SATISFACTORY QUALITY, INTEGRATION, NON-INFRINGEMENT
OF THIRD PARTY RIGHTS AND TITLE OR QUIET ENJOYMENT.
UNIDEN DOES NOT WARRANT THAT THE UNIDEN CODE IS
ERROR-FREE OR WILL OPERATE WITHOUT INTERRUPTION. NO
RIGHTS OR REMEDIES REFERRED TO IN ARTICLE 2A OF THE UCC
WILL BE CONFERRED ON YOU UNLESS EXPRESSLY GRANTED
HEREIN.
(C) IF APPLICABLE LAW REQUIRES ANY WARRANTIES WITH RESPECT
TO THE UNIDEN CODE, ALL SUCH WARRANTIES ARE LIMITED IN
DURATION TO THIRTY (30) DAYS FROM THE DATE OF DELIVERY.
(D) NO ORAL OR WRITTEN INFORMATION OR ADVICE GIVEN BY
UNIDEN, ITS DEALERS, SUPPLIERS, DISTRIBUTORS, AGENTS OR
EMPLOYEES SHALL CREATE A WARRANTY OR IN ANY WAY
INCREASE THE SCOPE OF ANY WARRANTY PROVIDED HEREIN.
6. LIMITATION OF LIABILITY
(A) NEITHER UNIDEN NOR ITS SUPPLIERS SHALL BE LIABLE TO YOU
OR ANY THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL,
PUNITIVE, COVER OR CONSEQUENTIAL DAMAGES ( INCLUDING,
BUT NOT LIMITED TO, DAMAGES FOR THE INABILITY TO USE
EQUIPMENT OR ACCESS DATA, LOSS OF BUSINESS, LOSS OF
PROFITS, BUSINESS INTERRUPTION OR THE LIKE), ARISING OUT
OF THE USE OF, OR INABILITY TO USE, THE UNIDEN CODE AND
BASED ON ANY THEORY OF LIABILITY INCLUDING BREACH OF
CONTRACT, BREACH OF WARRANTY, TORT (INCLUDING
NEGLIGENCE), PRODUCT LIABILITY OR OTHERWISE, EVEN IF
UNIDEN OR ITS REPRESENTATIVES HAVE BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES AND EVEN IF A REMEDY SET
FORTH HEREIN IS FOUND TO HAVE FAILED OF ITS ESSENTIAL
PURPOSE.
(B) UNIDEN'S TOTAL LIABILITY TO YOU FOR ACTUAL DAMAGES FOR
ANY CAUSE WHATSOEVER WILL BE LIMITED TO THE GREATER OF
$10 OR THE AMOUNT PAID BY YOU FOR THE UNIDEN CODE THAT
CAUSED SUCH DAMAGE.
(C) THE FOREGOING LIMITATIONS ON LIABILITY ARE INTENDED TO
APPLY TO THE WARRANTIES AND DISCLAIMERS ABOVE AND ALL
OTHER ASPECTS OF THIS EULA.
7. COMPLIANCE WITH LAWS
Uniden and its affiliates, which offer the Uniden Code to you, are headquartered
in the United States. Uniden makes no representation that the Uniden Code is
appropriate or legal for use inside or outside the United States. You are
responsible for all compliance with your local laws, and use of the Uniden Code
where illegal is expressly prohibited.
8. GOVERNING LAW AND VENUE
This EULA shall be interpreted, construed and governed by the laws of the State
of Texas, USA, without reference to its laws relating to conflicts of law and not
including the provisions of the 1980 United Nations Convention on Contracts for
the International Sale of Goods. Venue for all disputes arising under this
Agreement shall lie exclusively in the District Courts of the State of Texas in
Tarrant County or the Federal District Courts of the Northern District of Texas (as
permitted by law) and each party agrees not to contest the personal jurisdiction
of these courts. Notwithstanding the foregoing, however, Uniden shall have the
right to commence and prosecute any legal or equitable action or proceeding
before any non-US court of competent jurisdiction to obtain injunctive or other
relief in the event that, in the opinion of Uniden, such action is necessary or
desirable.
9. GENERAL PROVISIONS.
This EULA contains the complete agreement between the parties with respect to
the subject matter hereof, and supersedes all prior or contemporaneous
agreements or understandings, whether oral or written. You agree that any
varying or additional terms contained in any purchase order or other written
notification or document issued by you in relation to the Uniden Code licensed
hereunder shall be of no effect. The failure or delay of Uniden to exercise any of
its rights under this EULA or upon any breach of this EULA shall not be deemed
a waiver of those rights or of the breach.
If any provision of this EULA shall be held by a court of competent jurisdiction to
be contrary to law, that provision will be enforced to the maximum extent
permissible, and the remaini ng provisions of this EULA will remain in full force
and effect.
All questions concerning this EULA shall be directed to: Uniden America
Corporation, 4700 Amon Carter Boulevard, Fort Worth, Texas 76155.
UNIDEN and other trademarks contained in the Uniden Code are trademarks or
registered trademarks of Uniden America Corporation in the United States and/or
other countries. You may not remove or alter any trademark, trade names,
product names, logo, copyright or other proprietary notices, legends, symbols or
labels in the Uniden Code. This EULA does not authorize you to use the UNIDEN
name or any of their respective trademarks.
Trademarks and registered trademarks:
All products or service names mentioned in the Uniden Code are trademarks or
registered trademarks of Uniden America Corporation.
Copyright © 2003-2004
Uniden America Corporation
ALL RIGHTS RESERVED
< BCD396T Operation Specification >
7.13.
REMOTE COMMAND
【 Remote Communication Format 】
BPS rate
Start/Stop bit
Data Length
Parity Check
Code
Flow Control
Return Code
:
:
:
:
:
:
:
9600/19200/38400/57600/115200 bps
1 bit, 1 bit
8 bit
None
ASCII
None
Carriage Return only
【 FORMAT OF THIS DOCUMENT 】
<COMMAND NAME>
Summary explanation of the function of the command
Controller → Radio
Command format
Radio → Controller
Response format
NOTE
1. Any command is required to wait a response from the scanner,
then, next command will be acceptable.
2. All memory access commands are acceptable in only Program Mode.
Use PRG command to enter Program Mode, and EPG command to exit.
3. Error message isn't described in this document,
but the scanner returns error message to the controller as follows.
1)Command format error / Value error
: ERR[\r]
2)The command is invalid at the time
: NG[\r]
3)Framing error
: FER[\r]
4)Overrun error
: ORER[\r]
4. [\r] means "to hit the Enter key" or "to send the Return code".
5. Several commands or responses with long format are described like multi-line
because of the page width but their formats are only single line, actually.
6. In set command, only "," parameters are not changed.
7. The set command is aborted if any format error is detected.
8. [INDEX] or [xxx_INDEX] is the index of internal memory chain.
Dynamic Memory Allocation Structure always uses it as a handle to access data
and to trace forward/reverse or up/down index.
The range of the index is from 1 to maximum memory block (about 7600).
186
< BCD396T Operation Specification >
9. [FRQ], [BASEx] and [LIMIT_x] are frequency format.
It is showed by 8digit number without decimal point.
The order of the digits is from 1 GHz digit to 100 Hz digit.
ex. 08510125 means 851.0125MHz
10. [TGID] shows TGID format. The formats depend on Trunked System Type.
See another Appendix to get further information.
11. [NAME] shows each custom name. If user set only space character, the name will
return to default name.
Remote Command List
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
Category
Remote Control
System information
Programming Mode
Control
System Setting
Scan Settings
Command
GID
KEY
POF
QSH
STS
GLG
MDL
VER
PRG
EPG
BLT
BSV
CLR
KBP
OMS
PRI
AGV
SCT
SIH
SIT
QSL
QGL
CSY
DSY
CPS
SIN
TRN
TFQ
AGC
AGT
DGR
GIN
ACC
ACT
DCH
CIN
TIN
Function
Get Current Talkgroup ID Status
Push KEY
Power OFF
Go to quick search hold mode
Get Status
Get Reception Status
Get Model Info
Get Firmware Version
Enter Program Mode
Exit Program Mode
Get/Set Backlight
Get/Set Battery Save
Clear All Memory
Get/Set Key Beep
Get/Set Opening Message
Get/Set Priority Mode
Get/Set Auto Gain Control
Get System Count
Get System Index Head
Get System Index Tail
Get/Set System Quick Lockout
Get/Set Group Quick Lockout
Create System
Delete System
Copy System
Get/Set System Info
Get/Set Trunk Info
Get/Set Trunk Frequency Info
Append Channel Group
Append TGID Group
Delete Group
Get/ Set Group Info
Append Channel
Append TGID
Delete Channel
Get/Set Channel Info
Get/Set TGID Info
187
Program
Mode Only
○
○
○
○
○
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
< BCD396T Operation Specification >
Category
38
39
40
41
42
43
44
45
46
Scan Settings
(Continuation)
Search / Close Call
Settings
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
Service Search
Settings
Custom Search
Settings
Weather Settings
Tone-Out Settings
On-Air Clone Settings
LCD Contrast Setting
Volume Level Settings
Squelch Level Settings
APCO Data Setting
Test
Program
Mode Only
Command
Function
GLI
ULI
LOI
REV
FWD
RMB
MEM
SCO
GLF
ULF
LOF
CLC
Get Lockout TGID(for RVW L/O ID)
Unlock TGID (for RVW L/O ID)
Lockout ID (TGID)
Get Rev Index
Get Fwd Index
Get Remains of Memory Block
Get Memory Used
Get/Set Search/Close Call Settings
Get/Set
Broadcast
Screen
Band
Settings
Get Global Lockout Frequency
Unlock Global L/O
Lockout Frequency
Get/Set Close Call Settings
○
○
○
SSP
Get/Set Service Search Settings
○
CSG
CSP
WXS
SGP
TON
AIR
CNT
VOL
SQL
P25
WIN
BAV
Get/Set Custom Search Group
Get/Set Custom Search Settings
Get/Set Weather Setting
Get/Set SAME Group Settings
Get/Set Tone-Out Settings
Get/Set On-Air Clone Settings
Get/Set LCD Contrast Settings
Get/Set Volume Level Settings
Get/Set Squelch Level Settings
Get/Set APCO Data Settings
*Get Windows Voltage
*Get Battery Voltage
○
○
○
○
○
○
○
BBS
188
O
O
O
O
O
O
O
O
O
O
< BCD396T Operation Specification >
============================================================================
<COMMAND GID>
Get Current Talkgroup ID Status
========================================================================================
Controller → Radio
①
GID[\r]
Radio → Controller
①
GID,[SYS_TYPE],[TGID],[ID_SRCH_MODE],[NAME1],[NAME2],[NAME3][\r]
[SYS_TYPE]
[TGID]
[ID_SRCH_MODE]
: System Type
: TGID
0:ID:SCAN mode
1:ID:SEARCH mode
: SYSTEM NAME (Alpha Tag)
: GROUP NAME (Alpha Tag)
: TGID NAME (Alpha Tag)
[NAME1]
[NAME2]
[NAME3]
FUNCTION
This command returns TGID currently displayed on LCD.
If you get the TGID once, the scanner returns ,,,,,[\r] until next
reception.
NOTE
This command returns ,,,,,[\r], when TGID is not displayed.
=====================================================================================
<COMMAND KEY>
Push KEY
=====================================================================================
Controller → Radio
①
KEY,[KEY_CODE],[KEY_MODE][\r]
Radio → Controller
①
KEY,OK[\r]
[KEY_CODE]
M
F
H
S
L
1
2
3
4
5
6
7
8
9
0
.(dot)
E
>
<
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
MENU
F
HOLD
SCAN/SEARCH
L/O
1/PRI
2/WX
3
4
5
6
7/RCL
8
9
0
./NO/REV
E/YES/ATT
VFO RIGHT
VFO LEFT
189
* Set "P" to KEY_MODE.
* Set "P" to KEY_MODE.
< BCD396T Operation Specification >
[KEY_MODE]
^
P
: VFO PUSH
: POWER/LIGHT/LOCK
P
L
H
R
:
:
:
:
Press (One Push)
Long Press (Press and Hold a few second)
Hold (Press and Hold until Release receive)
Release (Cancel Hold state)
Ex.1) Press MENU KEY
→
KEY,M,P[\r]
←
OK[\r]
Ex.2) Press F + SCAN KEY
→
KEY,F,H[\r]
←
OK[\r]
→
KEY,S,P[\r]
←
OK[\r]
→
KEY,F,R[\r]
→
OK[\r]
Ex.3) Press and Hold L/O KEY
→
KEY,L,L[\r]
←
OK[\r]
: Hold F KEY
: Press SCAN KEY (F + SCAN KEY operation)
: Release F KEY
The scanner is not turned off by this command.
=====================================================================================
<COMMAND POF>
Power OFF
=====================================================================================
Controller → Radio
①
POF[\r]
Radio → Controller
①
POF,OK[\r]
Turns off the scanner.
After this command, the scanner doesn't accept any command.
=====================================================================================
<COMMAND QSH>
Go to quick search hold mode
=====================================================================================
Controller → Radio
①
QSH,[FRQ],[STP],[MOD],[ATT],[DLY],[SKP],[CODE_SRCH],[BSC],[REP][\r]
Radio → Controller
①
QSH,OK[\r]
[FRQ]
[STP]
: Frequency (The right frequency)
: Search Step
(AUTO,500,625,750, .... , 5000,10000)
AUTO : AUTO
500
: 5k
625 : 6.25k
750
: 7.5 k
833 : 8.33k
1000 : 10k
190
< BCD396T Operation Specification >
②
1250 : 12.5k
1500 : 15k
2000 : 20k
2500 : 25k
5000 : 50k
10000 : 100k
[MOD]
: Modulation
(AUTO/AM/FM/NFM/WFM)
[ATT]
: Attenuation
(0:OFF / 1:ON)
[DLY]
: Delay Time
(0:OFF / from 1 to 5)
[SKP]
: Data Skip
(0:OFF / 1:ON)
[CODE_SRCH] : CTCSS/DCS Search
(0:OFF / 1:ON)
[BSC]
: Broadcast Screen
(16digit: ########・・#)
(each # is 0 or 1)
|||||||| +- Band10
0 means OFF
||||||||
:
1 means ON
|||||||+---- Band 2
||||||+----- Band 1
|||||+------ AM*(always 0)
||||+------- NOAA WX
|||+-------- VHF TV
||+--------- UHF TV
|+---------- FM
+----------- Pager
* AM : valid for BR330T(invalid for BCD396T)
[REP]
: Repeater Find
(0:OFF / 1:ON)
QSH,NG[\r]
This command is invalid when the scanner is in Menu Mode, during Direct
Entry operation, during Quick Save operation.
FUNCTION
SS specifies arbitrary frequency and changes to Quick Search Hold (VFO) mode.
Parameter, such as STP, changes the contents of Srch/CloCall option.
=====================================================================================
<COMMAND STS>
Get Current Status
=====================================================================================
Controller → Radio
①
STS[\r]
Radio → Controller
①
STS,[DSP_FORM],[L1_CHAR],[L1_MODE],[L2_CHAR],[L2_MODE],[L3_CHAR],[L3_MODE],
[L4_CHAR],[L4_MODE],・・・・,[L8_CHAR],[L8_MODE],[SQL],[MUT],[BAT],[WAT][\r]
[DSP_FORM]
[L1_CHAR]
[L1_MODE]
[L2_CHAR]
[L2_MODE]
[L3_CHAR]
[L3_MODE]
[L4_CHAR]
[L4_MODE]
: Display Form
(4 - 8dight:########)
(each # is 0 or 1)
0 means Small Font
1 means Large Font
: Line1 Characters 16char (fixed length)
: Line1 Display Mode 16char
: Line2 Characters 16char (fixed length)
: Line2 Display Mode 16char
: Line3 Characters 16char (fixed length)
: Line3 Display Mode 16char
: Line4 Characters 16char (fixed length)
: Line4 Display Mode 16char
191
< BCD396T Operation Specification >
[L8_CHAR]
[L8_MODE]
[SQL]
[MUT]
[BAT]
[WAT]
:
:
:
:
:
:
:
:
Line8 Characters 16char (fixed length)
Line8 Display Mode 16char
Squelch Status
(0:CLOSE / 1:OPEN)
Mute Status
(0:OFF / 1:ON)
Battery Low Status
(0:No Alert / 1:Alert)
Weather Alert Status (0:No Alert / 1: Alert)
$$$: Alert SAME CODE (SAME EVENT CODE)
NOTE:
Display Mode for Line1 – Line8
(space) : NORMAL CHAR,
*
: REVERSE CHAR
_ (Under bar) : Underline
If all 16chars are normal, only "," is sent.
The number of [Lx_CHAR] and [Lx_MODE] depend on Display Form.
Ex.1)
┌------------------┐
│ -- M E N U -- |
│Program System |
│Srch/CloCall Opt|
│Search for . . .|
└------------------┘
→ STS[\r]
← 1111,
-- M E N U -- ,
________________,
Program System ,
****************,
Srch/CloCall Opt,
,
Search for. . . ,
,
1,0,0,0,[\r]
Returns current scanner status.
Ex.2)
┌-------------------┐
| HOLD L/O
|
│System 1
|
│851.0125MHz
|
│P NFM ATT
|
│S1:
5
|
|GRP 2
WX |
└-------------------┘
→ STS[\r]
← 01100,
HOLD L/O
,
,
SYSTEM 1
,
,
851.0125MHz
,
,
P NFM ATT
,
,
S1:
5
,
192
Squelch Status
:
:
Battery Low Status :
Weather Alert Status
Mute Status
←
←
←
←
←
←
←
←
[L1_CHAR]
[L1_MODE]
[L2_CHAR]
[L2_MODE]
[L3_CHAR]
[L3_MODE]
[L4_CHAR]
[L4_MODE]
Squelch Status
:
Mute Status
:
Battery Low Status :
Weather Alert Status
←
←
←
←
←
←
←
←
←
OPEN
OFF
No Alert
: No Alert
[L1_CHAR]
[L1_MODE]
[L2_CHAR]
[L2_MODE]
[L3_CHAR]
[L3_MODE]
[L4_CHAR]
[L4_MODE]
[L5_CHAR]
CLOSE
ON
No Alert
: Alert
< BCD396T Operation Specification >
,
← [L5_MODE]
GRP 2
WX,
← [L6_CHAR]
,
← [L6_MODE]
0,1,0,1,[\r]
Returns current scanner status.
=====================================================================================
<COMMAND GLG>
Get Reception Status
=====================================================================================
Controller → Radio
①
GLG[\r]
Radio → Controller
①
GLG,[FRQ/TGID],[MOD],[ATT],[CTCSS/DCS],[NAME1],[NAME2],[NAME3],[SQL],[MUT][\r]
GLG,,,,,,,,,[\r]
[FRQ/TGID]
[MOD]
[ATT]
[CTCSS/DCS]
[NAME1]
[NAME2]
[NAME3]
[SQL]
[MUT]
:
:
:
:
:
:
:
:
:
Frequency or TGID
Modulation
Attenuation
CTCSS/DCS Status
System or Search Name
Group Name
Channel Name
Squelch Status
Mute Status
(AM/FM/NFM/WFM)
(0:OFF / 1:ON)
(0-231: see CTCSS/DCS Code List)
(0:CLOSE / 1:OPEN)
(0:OFF / 1:ON)
Get reception status.
The Scanner returns GLG,,,,,,,,,[\r] until it detects a frequency or a TGID.
=====================================================================================
<COMMAND MDL>
Get Model Info
=====================================================================================
Controller → Radio
①
MDL[\r]
Radio → Controller
①
MDL,BCD396T[\r]
Returns Model Information.
=====================================================================================
<COMMAND VER>
Get Firmware Version
=====================================================================================
Controller → Radio
①
VER[\r]
Radio → Controller
①
VER,VR1.00[\r]
Returns Firmware Version.
193
< BCD396T Operation Specification >
=====================================================================================
<COMMAND PRG>
Enter Program Mode
=====================================================================================
Controller → Radio
①
PRG[\r]
Radio → Controller
①
PRG,OK[\r]
②
PRG,NG[\r]
This command is invalid when the scanner is in Menu Mode, during Direct
Entry operation, during Quick Save operation.
The scanner goes to Program Mode.
The scanner displays "Remote Mode" on first line
and "Keypad Lock" on second line in Program Mode.
And POWER key and Function key are valid in Program Mode.
=====================================================================================
<COMMAND EPG>
Exit Program Mode
=====================================================================================
Controller → Radio
①
EPG[\r]
Radio → Controller
①
EPG,OK[\r]
The scanner exits from Program Mode.
Then the scanner goes to Scan Hold Mode.
=====================================================================================
<COMMAND BLT>
Get/Set Backlight
=====================================================================================
Controller → Radio
①
BLT[\r]
: Get Backlight Setting
②
BLT,##[\r]
: Set Backlight Setting
Radio → Controller
①
BLT,##[\r]
②
BLT,OK[\r]
## means Backlight Setting
IF : INFINITE
10 : 10sec
30 : 30sec
KY : KEYPRESS
SQ : SQUELCH
Get/Set Backlight Setting.
This command is only acceptable in Programming Mode.
194
< BCD396T Operation Specification >
=====================================================================================
<COMMAND BSV>
Get/Set Battery Save
=====================================================================================
Controller → Radio
①
BSV[\r]
: Get Battery Save Setting
②
BSV,#[\r]
: Set Battery Save Setting
Radio → Controller
①
BSV,#[\r]
②
BSV,OK[\r]
# means Battery Save Setting
(0:OFF / 1:ON)
Get/Set Battery Save Setting.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND CLR>
Clear All Memory
=====================================================================================
Controller → Radio
①
CLR[\r]
Radio → Controller
①
CLR,OK[\r]
All the memories are set for initial setting.
This command is only acceptable in Programming Mode.
Note) Need about 10 seconds execute time.
Only PC Control (Baud Rate) does not become an initial-setting value.
=====================================================================================
<COMMAND KBP>
Get/Set Key Beep
=====================================================================================
Controller → Radio
①
KBP[\r]
: Get Key Beep Setting
②
KBP,[LEVEL][¥r]
: Set Key Beep Setting
Radio → Controller
①
KBP,[LEVEL][\r]
②
KBP,OK[\r]
Get/Set Key Beep Setting.
[LEVEL]
: Beep Level
(0:Auto / 1-15 /99:OFF)
This command is only acceptable in Programming Mode.
195
< BCD396T Operation Specification >
=====================================================================================
<COMMAND OMS>
Get/Set Opening Message
=====================================================================================
Controller → Radio
①
OMS[\r]
②
OMS,[L1_CHAR],[L2_CHAR],[L3_CHAR],[L4_CHAR][\r]
Radio → Controller
①
OMS,[L1_CHAR],[L2_CHAR],[L3_CHAR],[L4_CHAR][\r]
②
OMS,OK[\r]
Get/Set Opening
[L1_CHAR]
[L2_CHAR]
[L3_CHAR]
[L4_CHAR]
Message.
: Line1 Characters
: Line2 Characters
: Line3 Characters
: Line4 Characters
(max.16char)
(max.16char)
(max.16char)
(max.16char)
If only space code is set in character area,
the message returns default message.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND PRI>
Get/Set Priority Mode
=====================================================================================
Controller → Radio
①
PRI[\r]
: Get Priority Mode Setting
②
PRI,#[\r]
: Set Priority Mode Setting
Radio → Controller
①
PRI,#[\r]
②
PRI,OK[\r]
# means Priority Setting
(0:OFF / 1:ON / 2:PLUS ON)
Get/Set Priority Mode.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND AGV>
Get/Set Auto Gain Control
=====================================================================================
Controller → Radio
①
AGV[\r]
: Get Auto Gain Control Setting
②
AGV,[AGC_ANALOG],[AGC_DIGITAL][\r]
: Set Auto Gain Control Setting
Radio → Controller
① AGV,[AGC_ANALOG],[AGC_DIGITAL][\r]
② AGV,OK[\r]
Get/Set AGC Setting.
[AGC_ANALOG] : AGC Setting for Analog Audio (0:OFF / 1:ON)
[AGC_DIGITAL] : AGC Setting for Digital Audio (0:OFF / 1:ON)
This command is only acceptable in Programming Mode.
196
< BCD396T Operation Specification >
=====================================================================================
<COMMAND SCT>
Get System Count
=====================================================================================
Controller → Radio
①
SCT[\r]
Radio → Controller
①
SCT,###[\r]
: ### (0-400)
Returns the number of stored System.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND SIH>
Get System Index Head
=====================================================================================
Controller → Radio
①
SIH[\r]
Radio → Controller
①
SIH,[SYS_INDEX][\r]
Returns the first index of stored system list.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND SIT>
Get System Index Tail
=====================================================================================
Controller → Radio
①
SIT[\r]
Radio → Controller
①
SIT,[SYS_INDEX][\r]
Returns the last index of stored system list.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND QSL>
Get/Set System Quick Lockout
=====================================================================================
Controller → Radio
①
QSL[\r]
②
QSL,[PAGE0],[PAGE1],[PAGE2],[PAGE3],[PAGE4],[PAGE5],[PAGE6],[PAGE7],[PAGE8],
[PAGE9][\r]
Radio → Controller
①
QSL,[PAGE0],[PAGE1],[PAGE2],[PAGE3],[PAGE4],[PAGE5],[PAGE6],[PAGE7],[PAGE8],
[PAGE9][\r]
②
QSL,OK[\r]
Returns the System Quick Key status.
[PAGE0] – [PAGE9]
: ########## (each # is 0 - 2)
0 means : Quick Key don’t assign
1 means ON
197
< BCD396T Operation Specification >
[PAGE0]
[PAGE1]
[PAGE2]
[PAGE3]
[PAGE4]
[PAGE5]
[PAGE6]
[PAGE7]
[PAGE8]
[PAGE9]
:
:
:
:
:
:
:
:
:
:
Quick
Quick
Quick
Quick
Quick
Quick
Quick
Quick
Quick
Quick
2 means *
: Quick Key that turn off
The Order of Quick Key is as same as LCD Icon.
Key 1 - 10
Key11 - 20
Key21 - 30
Key31 - 40
Key41 - 50
Key51 - 60
Key61 - 70
Key71 - 80
Key81 - 90
Key91 - 100
This command is only acceptable in Programming Mode.
It cannot turn on/off the Quick Key that has no System.
=====================================================================================
<COMMAND QGL>
Get/Set Group Quick Lockout
=====================================================================================
Controller → Radio
①
QGL,[SYS_INDEX],[\r]
②
QGL,[SYS_INDEX], ##########[\r]
Radio → Controller
①
QGL,##########[\r]
②
QGL,OK[\r]
Returns Group Quick Key status of current System.
: ########## (each # is 0 - 2)
0 means : Quick Key don’t assign
1 means ON
2 means *
: Quick Key that turn off
The Order of Quick Key is as same as LCD Icon.
This command is only acceptable in Programming Mode.
It cannot turn on/off the Quick Key that has no Group.
=====================================================================================
<COMMAND CSY>
Create System
=====================================================================================
Controller → Radio
①
CSY,[SYS_TYPE][\r]
Radio → Controller
①
CSY,[SYS_INDEX][\r]
[SYS_TYPE]
: System Type
CNV
M82S
M82P
M92
MV2
MU2
M81S
M81P
MP25
:
:
:
:
:
:
:
:
:
CONVENTIONAL
MOT_800_T2_STD
MOT_800_T2_SPL
MOT_900_T2
MOT_VHF_T2
MOT_UHF_T2
MOT_800_T1_STD
MOT_800_T1_SPL
MOT_P25
198
< BCD396T Operation Specification >
[SYS_INDEX]
EDN
: EDACS_NARROW
EDW
: EDACS_WIDE
EDS
: EDACS_SCAT
LTR
: LTR
: The Index if Created System
Creates a system and returns created system index.
The index is a handle to get/set system information.
Returns -1 if the scanner failed to create because of no resource.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND DSY>
Delete System
=====================================================================================
Controller → Radio
①
DSY,[SYS_INDEX][\r]
Radio → Controller
①
DSY,OK[\r]
[SYS_INDEX]
: System Index
This command deletes a System.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND CPS>
Copy System
=====================================================================================
Controller → Radio
①
CPS,[SYS_INDEX1],[NAME][\r]
Radio → Controller
①
CPS,[SYS_INDEX2][\r]
[SYS_INDEX1]
[NAME]
[SYS_INDEX2]
: The Index of Source System
: The Name of Copied System
: The Index of Copied System
Copies a system.
Returns -1 instead of SYS_INDEX2 if the scanner failed to copy
because of no resource.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND SIN>
Get/Set System Info
=====================================================================================
Controller → Radio
①
SIN,[INDEX][\r]
②
SIN,[INDEX],[NAME],[QUICK_KEY],[HLD],[LOUT],[DLY],[SKP],[MOD],[ATT],[APCO],
[THRESHOLD][\r]
Radio → Controller
①
SIN,[SYS_TYPE],[NAME],[QUICK_KEY],[HLD],[LOUT],[DLY],[SKP],[MOD],[ATT],[APCO],
[THRESHOLD],[REV_INDEX],[FWD_INDEX],[CHN_GRP_HEAD],[CHN_GRP_TAIL],[SEQ_NO][\r]
199
< BCD396T Operation Specification >
②
SIN,OK[\r]
[INDEX]
[SYS_TYPE]
[NAME]
[QUICK_KEY]
[HLD]
[LOUT]
[DLY]
[SKP]
[MOD]
:
:
:
:
:
:
:
:
:
[ATT]
:
[APCO]
:
[THRESHOLD]
[REV_INDEX]
[FWD_INDEX]
[CHN_GRP_HEAD]
[CHN_GRP_TAIL]
[SEQ_NO]
:
:
:
:
:
:
System Index
System Type
Name (max.16char)
Quick Key (1-100/.(dot) means none)
System Hold Time
(0-255)
Lockout
(0:Unlocked / 1:Lockout)
Delay Time
(0:OFF / from 1 to 5)
Data Skip
(0:OFF / 1:ON)
Modulation
(for Trunking System Only)
(AUTO/FM/NFM)
Attenuation
(for Trunking System Only)
(0:OFF/1:ON)
APCO Threshold Mode
(AUTO: Auto/MAN: Manual/DFLT: Default)
APCO Threshold
( 0-63 )
Reverse System Index of the Scan Setting
Forward System Index of the Scan Setting
Channel Group Index Head of the System
Channel Group Index Tail of the System
System Sequence Number (1-400)
Get/Set System Information.
The scanner returns only "," to punctuate for parameters which
are not appropriate the system type.
In set command, the scanner neglects the parameters that are not
appropriate the system type.
In set command, only "," parameters are not changed.
The set command is aborted if any format error is detected.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND TRN>
Get/Set Trunk Info
=====================================================================================
Controller → Radio
①
TRN,[INDEX][\r]
②
TRN,[INDEX],[ID_SEARCH],[S_BIT],[END_CODE],[AFS],[I-CALL],[C-CH],[EMG],[EMGL],
[FMAP],[CTM_FMAP],[BASE1],[STEP1],[OFFSET1],[BASE2],[STEP2],[OFFSET2],[BASE3],
[STEP3],[OFFSET3],[MFID][\r]
Radio → Controller
①
TRN,[ID_SEARCH],[S_BIT],[END_CODE],[AFS],[I-CALL],[C-CH],[EMG],[EMGL],[FMAP],
[CTM_FMAP],[BASE1],[STEP1],[OFFSET1],[BASE2],[STEP2],[OFFSET2],[BASE3],[STEP3],
[OFFSET3],[MFID],[TGID_GRP_HEAD],[TGID_GRP_TAIL],[ID_LOUT_GRP_HEAD],
[ID_LOUT_GRP_TAIL][\r]
②
TRN,OK[\r]
[INDEX]
[ID_SEARCH]
[S_BIT]
: System Index
: ID Search/Scan
: Motorola Status Bit
200
(0:ID Scan mode / 1: Search Mode)
(0:Ignore, 1:Yes)
< BCD396T Operation Specification >
[END_CODE]
[AFS]
[I-CALL]
[C-CH]
[EMG]
[EMGL]
[FMAP]
[CTM_FMAP]
:
:
:
:
:
:
:
:
Motorola End Code
(0:Ignore, 1:Yes)
EDACS Format
(0:Decimal / 1:AFS)
I-CALL
(0:OFF / 1:ON)
Control Channel Only (0:OFF / 1:ON)
Emergency Alert
(0:Ignore / 1-9:Alert)
Emergency Alert Level (0:OFF / 1 - 15)
Fleet Map
(0-16, 0-15:Preset, 16:Custom)
Custom Fleet Map Setting (######## : # is 0-E)
# means Size Code of each BLOCK (from 0 to 7)
0 : Size Code 0
1 : Size Code 1
2 : Size Code 2
3 : Size Code 3
4 : Size Code 4
5 : Size Code 5
6 : Size Code 6
7 : Size Code 7
8 : Size Code 8
9 : Size Code 9
A : Size Code 10
B : Size Code 11
C : Size Code 12
D : Size Code 13
E : Size Code 14
[BASE1]
: Base Frequency1
[STEP1]
: Step1
[OFFSET1]
: Offset1
[BASE2]
: Base Frequency2
[STEP2]
: Step2
[OFFSET2]
: Offset2
[BASE3]
: Base Frequency3
[STEP3]
: Step3
(for MOT UHF/VHF System only)
[OFFSET3]
: Offset3
(for MOT UHF/VHF System only)
[MFID]
: MFID
(for MOT P25 System only)
(0:Defalut/1:Mode1/2:Mode2)
[TGID_GRP_HEAD]
: TGID Index Head of the System
[TGID_GRP_TAIL]
: TGID Index Tail of the System
[ID_LOUT_GRP_HEAD]
: L/O TGID Group Index Head of the System
[ID_LOUT_GRP_TAIL]
: L/O TGID Group Index Tail of the System
Get/Sets Trunked System Information.
The scanner returns only "," to punctuate for parameters which
are not appropriate the system type.
In set command, the scanner neglects the parameters that are not
appropriate the system.
In set command, only "," parameters are not changed.
The set command is aborted if any format error is detected.
This command is only acceptable in Programming Mode.
201
< BCD396T Operation Specification >
=====================================================================================
<COMMAND TFQ>
Get/Set Trunk Frequency Info
=====================================================================================
Controller → Radio
①
TFQ,[CHN_INDEX][\r]TFQ,[CHN_INDEX],[FRQ],[LCN],[LOUT][\r]
Radio → Controller
①
TFQ,[FRQ],[LCN],[LOUT],[REV_INDEX],[FWD_INDEX],[SYS_INDEX],[GRP_INDEX][\r]
②
TFQ,OK[\r]
[CHN_INDEX]
[FRQ]
[LCN]
[LOUT]
[REV_INDEX]
[FWD_INDEX]
[SYS_INDEX]
[GRP_INDEX]
:
:
:
:
:
:
:
:
Channel Index
Frequency for Trunked System
LCN
Lockout
(0:Unlocked / 1:Lockout)
Reverse Frequency Index of the System Frequency Group
Forward Frequency Index of the System Frequency Group
System Index of the Frequency
Index of the System Frequency Group
In set command,
The set command
This command is
For Motorola or
only "," parameters are not changed.
is aborted if any format error is detected.
only acceptable in Programming Mode.
EDACS SCAT System, [LCN] is ignored.
=====================================================================================
<COMMAND AGC>
Append Channel Group
=====================================================================================
Controller → Radio
①
AGC,[SYS_INDEX][\r]
Radio → Controller
①
AGC,[GRP_INDEX][\r]
[SYS_INDEX]
[GRP_INDEX]
: System Index
: appended Channel Group Index
Append Channel Group to the system.
Returns -1 if the scanner failed to create because of no resource.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND AGT>
Append TGID Group
=====================================================================================
Controller → Radio
①
AGT,[SYS_INDEX][\r]
Radio → Controller
①
AGT,[GRP_INDEX][\r]
[SYS_INDEX]
[GRP_INDEX]
: System Index
: appended TGID Group Index
Append TGID Group to the system.
202
< BCD396T Operation Specification >
Returns -1 if the scanner failed to create because of no resource.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND DGR>
Delete Group
=====================================================================================
Controller → Radio
①
DGR,[GRP_INDEX][\r]
Radio → Controller
①
DGR,OK[\r]
[GRP_INDEX]
: Group Index
This command deletes a Channel Group or TGID Group.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND GIN>
Get/Set Group Info
=====================================================================================
Controller → Radio
①
GIN,[GRP_INDEX][\r]
②
GIN,[GRP_INDEX],[NAME],[QUICK_KEY],[LOUT][\r]
Radio → Controller
①
GIN,[GRP_TYPE],[NAME],[QUICK_KEY],[LOUT],[REV_INDEX],[FWD_INDEX],[SYS_INDEX],[C
HN_HEAD],[CHN_TAIL],[SEQ_NO][\r]
②
GIN,OK[\r]
[GRP_INDEX]
[GRP_TYPE]
[NAME]
[QUICK_KEY]
[LOUT]
[REV_INDEX]
[FWD_INDEX]
[SYS_INDEX]
[CHN_HEAD]
[CHN_TAIL]
[SEQ_NO]
:
:
:
:
:
:
:
:
:
:
:
Group Index
Group Type (C:Channel Group / T:TGID Group)
Name (max.16char)
Quick Key (1-9,0: means 10, .(dot): means none)
Lockout
(0:Unlocked / 1:Lockout)
Reverse Group Index of the System
Forward Group Index of the System
System Index
Channel Index Head of the Group List
Channel Index Tail of the Group List
Group Sequence Number of the System
Get/Set Group Information.
In set command, only "," parameters are not changed.
The set command is aborted if any format error is detected.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND ACC>
Append Channel
=====================================================================================
Controller → Radio
①
ACC,[GRP_INDEX][\r]
Radio → Controller
①
ACC,[CHN_INDEX][\r]
203
< BCD396T Operation Specification >
[GRP_INDEX]
[CHN_INDEX]
: Channel Group Index
: appended Channel Index
Append Channel to the group.
Returns -1 if the scanner failed to create because of no resource.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND ACT>
Append TGID
=====================================================================================
Controller → Radio
①
ACT,[GRP_INDEX][\r]
Radio → Controller
①
ACT,[INDEX][\r]
[GRP_INDEX]
[TGID_INDEX]
: TGID Group Index
: appended TGID Index
Append Channel to the group.
Returns -1 if the scanner failed to create because of no resource.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND DCH>
Delete Channel
=====================================================================================
Controller → Radio
①
DCH,[INDEX][\r]
Radio → Controller
①
DCH,OK[\r]
[INDEX]
: Channel Index, TGID Index
or Frequency Index of Trunked System
This command deletes a Channel and TGID.
This command is also valid for deleting a frequency
for a Trunked System.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND CIN>
Get/Set Channel Info
=====================================================================================
Controller → Radio
①
CIN,[INDEX][\r]
②
CIN,[INDEX],[NAME],[FRQ],[MOD],[CTCSS/DCS],[TLOCK],
[LOUT],[PRI],[ATT],[ALT],[ALTL][\r]
Radio → Controller
①
CIN,[NAME],[FRQ],[MOD],[CTCSS/DCS],[TLOCK],[LOUT],[PRI],[ATT],[ALT],[ALTL],
[REV_INDEX],[FWD_INDEX],[SYS_INDEX],[GRP_INDEX],[\r]
②
CIN,OK[\r]
204
< BCD396T Operation Specification >
[INDEX]
[NAME]
[FRQ]
[MOD]
[ATT]
[CTCSS/DCS]
[TLOCK]
[LOUT]
[PRI]
[ALT]
[ALTL]
[REV_INDEX]
[FWD_INDEX]
[SYS_INDEX]
[GRP_INDEX]
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
Channel Index
Name (max.16char)
Channel Frequency
Modulation
(AUTO/AM/FM/NFM/WFM)
Attenuation
(0:OFF / 1:ON)
CTCSS/DCS Mode
(0-231: see CTCSS/DCS Code List)
CTCSS/DCS Tone Lockout (0:OFF / 1:ON)
Lockout
(0:Unlocked / 1:Lockout)
Priority
(0:OFF / 1:ON)
Alert Tone
(0:OFF / 1-9:Tone No)
Alert Tone Level
(0:AUTO/ 1-15)
Reverse Channel Index of the Channel Group
Forward Channel Index of the Channel Group
System Index of the Channel
Group Index of the Channel
Get/Set Channel
In set command,
The set command
This command is
Information.
only "," parameters are not changed.
is aborted if any format error is detected.
only acceptable in Programming Mode.
=====================================================================================
<COMMAND TIN>
Get/Set TGID Info
=====================================================================================
Controller → Radio
①
TIN,[INDEX][\r]
②
TIN,[INDEX],[NAME],[TGID],[LOUT],[PRI],[ALT],[ALTL][\r]
Radio → Controller
①
TIN,[NAME],[TGID],[LOUT],[PRI],[ALT],[ALTL],[REV_INDEX],[FWD_INDEX],
[SYS_INDEX],[GRP_INDEX][\r]
②
TIN,OK[\r]
[INDEX]
[NAME]
[TGID]
[LOUT]
[PRI]
[ALT]
[ALTL]
[REV_INDEX]
[FWD_INDEX]
[SYS_INDEX]
[GRP_INDEX]
:
:
:
:
:
:
:
:
:
:
:
TGID Index
Name (max.16char)
TGID
Lockout
(0:Unlocked / 1:Lockout)
Priority
(0:OFF / 1:ON)
Alert Tone
(0:OFF / 1-9:Tone No)
Alert Tone Level
(0:AUTO/ 1-15)
Reverse TGID Index of the TGID Group
Forward TGID Index of the TGID Group
System Index of the TGID
Group Index of the TGID
Get/Set TGID Information.
In set command, only "," parameters are not changed.
The set command is aborted if any format error is detected.
This command is only acceptable in Programming Mode.
205
< BCD396T Operation Specification >
=====================================================================================
<COMMAND GLI>
Get Lockout TGID (for Rvw L/O ID)
=====================================================================================
Controller → Radio
①
GLI,[SYS_INDEX][\r]
Radio → Controller
①
GLI,[TGID][\r]
GLI,-1[\r]
: No more lockout TGID
This command is used to get L/O TGID list of a system.
You should call this command again and again to get all L/O
TGID until the scanner returns -1 .
-1 means that no more L/O frequency exists.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND ULI>
Unlock TGID (for Rvw L/O ID)
=====================================================================================
Controller → Radio
①
ULI,[SYS_INDEX],[TGID][\r]
Radio → Controller
①
ULI,OK[\r]
This command unlocks a L/O TGID in a system.
The TGID is deleted from L/O list.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND LOI>
Lockout ID (TGID)
=====================================================================================
Controller → Radio
①
LOI,[SYS_INDEX],[TGID][\r]
Radio → Controller
①
LOI,OK[\r]
This command locks out a TGID for the system.
The TGID is added to L/O list.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND REV>
Get Rev Index
=====================================================================================
Controller → Radio
①
REV,[INDEX][\r]
Radio → Controller
①
REV,[INDEX][\r]
Returns reverse(backward) index of the index in the memory chain.
Returns -1 if no more index exists.
This command is only acceptable in Programming Mode.
206
< BCD396T Operation Specification >
=====================================================================================
<COMMAND FWD>
Get Fwd Index
=====================================================================================
Controller → Radio
①
FWD,[INDEX][\r]
Radio → Controller
①
FWD,[INDEX][\r]
Returns forward index of the index in the memory chain.
Returns -1 if no more index exists.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND RMB>
Get Remains of Memory Block
=====================================================================================
Controller → Radio
①
RMB[\r]
Radio → Controller
①
RMB,####[\r]
Returns the number of idle(free) memory block.
: #### (0-9999)
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND MEM>
Get Memory Used
=====================================================================================
Controller → Radio
①
MEM[\r]
Radio → Controller
①
MEM,###[\r]
Returns % memory used.
: ### (0-100)
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND SCO>
Get/Set Search/Close Call Settings
=====================================================================================
Controller → Radio
①
SCO[\r]
②
SCO,[STP],[MOD],[ATT],[DLY],[SKP],[CODE_SRCH],[BSC],[REP],[APCO],
[THRESHOLD],[MAX_STORE][\r]
Radio → Controller
①
SCO,[STP],[MOD],[ATT],[DLY],[SKP],[CODE_SRCH],[BSC],[REP],[APCO],
[THRESHOLD],[MAX_STORE][\r]
②
SCO,OK[\r]
207
< BCD396T Operation Specification >
[STP]
[MOD]
[ATT]
[DLY]
[SKP]
[CODE_SRCH]
[BSC]
[REP]
[APCO]
[THRESHOLD]
[MAX_STORE]
: Search Step
(AUTO,500,625,750, .... , 5000,10000)
AUTO : AUTO
500
: 5k
625
: 6.25k
750
: 7.5k
833
: 8.33k
1000 : 10k
1250 : 12.5k
1500 : 15k
2000 : 20k
2500 : 25k
5000 : 50k
10000 : 100k
: Modulation
(AUTO/AM/FM/NFM/WFM)
: Attenuation
(0:OFF / 1:ON)
: Delay Time
(0:OFF / from 1 to 5)
: Data Skip
(0:OFF / 1:ON)
: CTCSS/DCS Search
(0:OFF / 1:ON)
: Broadcast Screen
(16digit: ########・・#)
(each # is 0 or 1)
|||||||| +- Band10
0 means OFF
||||||||
:
1 means ON
|||||||+---- Band 2
||||||+----- Band 1
|||||+------ AM* (always 0)
||||+------- NOAA WX
|||+-------- VHF TV
||+--------- UHF TV
|+---------- FM
+----------- Pager
* AM : valid for BR330T(invalid for BCD396T)
: Repeater Find
(0:OFF / 1:ON)
: APCO Threshold Mode
(AUTO: Auto/MAN: Manual/DFLT: Default)
: APCO Threshold
(0 – 63 )
: Max Auto Store
(1-256)
Get/Set Search/Close Call Settings.
In set command, only "," parameters are not changed.
The set command is aborted if any format error is detected.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND BBS>
Get/Set Broadcast Screen Band Settings
=====================================================================================
Controller → Radio
①
BBS,[INDEX][\r]
②
BBS,[INDEX],[LIMIT_L],[LIMIT_H][\r]
Radio → Controller
①
BBS,[LIMIT_L],[LIMIT_H][\r]
②
BBS,OK[\r]
[SCR_INDEX]
: Index (1-9,0 means 10)
208
< BCD396T Operation Specification >
[LIMIT_L]
[LIMIT_H]
: Lower Limit Frequency (250000 –
: Upper Limit Frequency (250000 –
13000000)
13000000)
Get/Set Broadcast Screen Band Settings.
This command is Only acceptable in Programming Mode.
=====================================================================================
<COMMAND GLF>
Get Global Lockout Freq
=====================================================================================
Controller → Radio
①
GLF[\r]
Radio → Controller
①
GLF,[FRQ][\r]
GLF,-1[\r]
[FRQ]
: Lockout Frequency (250000-13000000)
This command is used to get Global L/O frequency list.
You should call this command again and again to get all-global
L/O frequency until the scanner returns -1 .
-1 means that no more L/O frequency exists.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND ULF>
Unlock Global L/O
=====================================================================================
Controller → Radio
①
ULF,[FRQ][\r]
Radio → Controller
①
ULF,OK[\r]
[FRQ]
: Lockout Frequency (250000-13000000)
This command unlocks a L/O frequency.
The frequency is deleted from L/O list.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND LOF
Lock Out Frequency
=====================================================================================
Controller → Radio
①
LOF,[FRQ][\r]
Radio → Controller
①
LOF,OK[\r]
[FRQ]
: Frequency (250000-13000000)
This command locks out a frequency.
The frequency is added to L/O list.
This command is only acceptable in Programming Mode.
209
< BCD396T Operation Specification >
=====================================================================================
<COMMAND CLC>
Get/Set Close Call Settings
=====================================================================================
Controller → Radio
①
CLC[\r]
②
CLC,[CC_MODE],[CC_OVERRIDE],[ALTM],[ALTB],[ALTL],[ALTP],[CC_BAND][\r]
Radio → Controller
①
CLC,[CC_MODE],[CC_OVERRIDE],[ALTM],[ALTB],[ALTL],[ALTP],[CC_BAND][\r]
②
CLC,OK[\r]
[CC_MODE]
[CC_OVERRIDE]
[ALTM]
: Mode
: Override
: Alert Mode
[ALTB]
[ALTL]
[ALTP]
: Alert Beep
: Alert Tone Level
: Close Call Pause
3
5
10
15
30
45
60
(1:ON / 0:OFF)
(1:ON / 0:OFF)
(N:NONE / B:BEEP / L:LIGHT/
A:BEEP+LIGHT)
(0:OFF / 1-9:Tone No)
(0:AUTO/ 1-15)
:
:
:
:
:
:
:
3
5
10
15
30
45
60
sec
sec
sec
sec
sec
sec
sec
INF : Infinite
[CC_BAND]
: Close Call Band
(7digit ####### )
(each # is 0 or 1)
||||||+ 800MHz+
0 means OFF
|||||+- UHF
1 means ON
||||+-- VHF HIGH2
|||+--- VHF HIGH1
||+---- AIR BAND
|+----- VHF LOW2
+------ VHF LOW1
Get/Set Close Call Settings.
In set command, only "," parameters are not changed.
The set command is aborted if any format error is detected.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND SSP>
Get/Set Service Search Settings
=====================================================================================
Controller → Radio
①
SSP,[SRCH_INDEX][\r]
②
SSP,[SRCH_INDEX],[DLY],[ATT],[HLD],[LOUT][\r]
Radio → Controller
①
SSP,[SRCH_INDEX],[DLY],[ATT],[HLD],[LOUT][\r]
②
SSP,OK[\r]
[SRCH_INDEX]
: Index
1 : Public Safety
2 : News
3 : HAM Radio
210
7 : CB Radio
8 : FRS/GMRS
9 : Racing
< BCD396T Operation Specification >
[DLY]
[ATT]
[HLD]
4 : Marine
5 : Railroad
6 : Air
: Delay Time
: Attenuation
: System Hold Time
[LOUT]
: Lockout
10 : TV Broadcast
11 : FM Broadcast
12 : Special
(0:OFF / from 1 to 5)
(0:OFF/1:ON)
(for Search with Scan)
(0-255)
(for Search with Scan)
(0:Unlocked / 1:Lockout)
The set command is aborted if any format error is detected.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND CSG>
Get/Set Custom Search Group
=====================================================================================
Controller → Radio
①
CSG[\r]
②
CSG,##########[\r]
: Status of Each Search Range
Radio → Controller
①
CSG,##########[\r]
②
CSG,OK[\r]
: ########## (each # is 0 or 1)
0 : valid
1 : invalid
The Order of Range is as same as LCD Icon.
Get/Set current status of the custom search range.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND CSP>
Get/Set Custom Search Settings
=====================================================================================
Controller → Radio
①
CSP,[SRCH_INDEX][\r]
②
CSP,[SRCH_INDEX],[NAME],[LIMIT_L],[LIMIT_H],[STP],[MOD],[ATT],[DLY],[SKP],[HLD]
,[LOUT],[C-CH],[APCO],[THRESHOLD][\r]
Radio → Controller
①
CSP,[NAME],[LIMIT_L],[LIMIT_H],[STP],[MOD],[ATT],[DLY],[SKP],[HLD],[LOUT],[CCH],[APCO],[THRESHOLD][\r]
②
CSP,OK[\r]
[SRCH_INDEX]
[NAME]
[LIMIT_L]
[LIMIT_H]
[STP]
:
:
:
:
:
Index (1-9,0 means 10)
Name (max.16char)
Lower Limit Frequency (250000-13000000)
Upper Limit Frequency (250000-13000000)
Search Step
(AUTO,500,625,750, .... , 5000,10000)
AUTO : AUTO
500
: 5k
625
: 6.25k
750
: 7.5k
211
< BCD396T Operation Specification >
833
: 8.33k
1000 : 10k
1250 : 12.5k
1500 : 15k
2000 : 20k
2500 : 25k
5000 : 50k
10000 : 100k
[MOD]
: Modulation
(AUTO/AM/FM/NFM/WFM)
[ATT]
: Attenuation
(0:OFF / 1:ON)
[DLY]
: Delay Time
(0:OFF / from 1 to 5)
[SKP]
: Data Skip
(0:OFF / 1:ON)
[HLD]
: System Hold Time
(0-255)
[LOUT]
: Lockout
(0:Unlocked / 1:Lockout)
[C-CH]
: Control Channel Only (0:OFF / 1:ON)
[APCO]
: APCO Threshold Mode
(AUTO: Auto/MAN: Manual/DFLT: Default)
[THRESHOLD]
: APCO Threshold
(0 – 63 )
Get/Set Custom Search Settings.
In set command, only "," parameters are not changed.
The set command is aborted if any format error is detected.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND WXS>
Get/Set Weather Settings
=====================================================================================
Controller → Radio
①
WXS[\r]
②
WXS,[DLY],[ATT],[ALT_PRI][\r]
Radio → Controller
①
WXS, [DLY],[ATT],[ALT_PRI][\r]
②
WXS,OK[\r]
[DLY]
[ATT]
[ALT_PRI]
: Delay Time
(0:OFF / from 1 to 5)
: Attenuation
(0:OFF / 1:ON)
: Weather Alert Priority (0:OFF / 1:ON)
Get/Set Weather Priority Settings.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND SGP>
Get/Set SAME Group Settings
=====================================================================================
Controller → Radio
①
SGP,[SAME_INDEX][\r]
②
SGP,[SAME_INDEX],[NAME],[FIPS1],[FIPS2],[FIPS3],[FIPS4],[FIPS5],[FIPS6],
[FIPS7],[FIPS8][\r]
Radio → Controller
①
SGP,[NAME],[FIPS1],[FIPS2],[FIPS3],[FIPS4],[FIPS5],[FIPS6],[FIPS7],[FIPS8][\r]
②
SGP,OK[\r]
[SAME_INDEX]
[NAME]
[FIPS1-8]
: SAME Index (1-5)
: SAME Group Name (max.16char)
: FIPS Code (6digit:000000-999999, or -------- means none)
212
< BCD396T Operation Specification >
Get/Set SAME Group Settings.
In set command, only "," parameters are not changed.
The set command is aborted if any format error is detected.
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND TON>
Get/Set Tone-Out Settings
=====================================================================================
Controller → Radio
①
TON[INDEX][\r]
②
TON,[INDEX],[NAME],[FRQ],[MOD],[ATT],[DLY],[ALT],[ALTL],[TONE_A],[DUR_A],
[TONE_B],[DUR_B],[GAP][\r]
Radio → Controller
①
TON,[INDEX],[NAME],[FRQ],[MOD],[ATT],[DLY],[ALT],[ALTL],[TONE_A],[DUR_A],
[TONE_B],[DUR_B],[GAP][\r]
②
TON,OK[\r]
[INDEX]
[NAME]
[FRQ]
[MOD]
[ATT]
[DLY]
[ALT]
[ALTL]
[TONE_A]
:
:
:
:
:
:
:
:
:
[DUR_A]
:
[TONE_B]
[DUR_B]
[GAP]
:
:
:
Index (1-9,0 means 10)
Name (max.16char)
Channel Frequency
Modulation
(AUTO/FM/NFM)
Attenuation
(0:OFF / 1:ON)
Delay Time
(0:OFF / 1-5)
Alert Tone
(0:OFF/1-9:Tone No.)
Alert Tone Level
(0:AUTO/1-15)
Tone A Frequency
ex.) 10000 means 1000.0Hz
Duration A
ex.) 1 means 1ms
Tone B Frequency
Duration B
Tone Gap
ex.) 1 means 1ms
Get/Set Tone-Out Settings
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND AIR>
Get/Set On-Air Clone Settings
=====================================================================================
Controller → Radio
①
AIR[\r]
②
AIR,[FRQ],[MOD][\r]
Radio → Controller
①
AIR,[FRQ],[MOD][\r]
②
AIR,OK[\r]
[FRQ]
[MOD]
: Frequency
: Modulation
(AUTO/FM/NFM)
Get/Set On-Air Clone Settings
This command is only acceptable in Programming Mode.
213
< BCD396T Operation Specification >
=====================================================================================
<COMMAND CNT>
Get/Set LCD Contrast Settings
=====================================================================================
Controller → Radio
①
CNT[\r]
Radio → Controller
①
CNT,[CONTRAST][\r]
[CONTRAST]
: LCD Contrast
(1-15)
Get/Set LCD Contrast Settings
This command is only acceptable in Programming Mode.
=====================================================================================
<COMMAND VOL>
Get/Set Volume Level Settings
=====================================================================================
Controller → Radio
①
VOL[\r]
②
VOL,[LEVEL][\r]
Radio → Controller
①
VOL,[LEVEL][\r]
②
VOL,OK[\r]
[LEVEL]
: Volume Level
(0:OFF / 1-15 )
=====================================================================================
<COMMAND SQL>
Get/Set Squelch Level Settings
=====================================================================================
Controller → Radio
①
SQL[\r]
②
SQL,[LEVEL][\r]
Radio → Controller
①
SQL,[LEVEL][\r]
②
SQL,OK[\r]
[LEVEL]
: Squelch Level
(0:OPEN / 1-14 / 15:CLOSE)
=====================================================================================
<COMMAND P25>
Get/Set APCO Data Settings
=====================================================================================
Controller → Radio
①
P25[\r]
②
P25,[THRESHOLD][\r]
Radio → Controller
①
P25,[APCO],[THRESHOLD],[ERR_RATE][\r]
②
P25,OK[\r]
P25,NG[\r]
[APCO]
: APCO Threshold Mode
214
:
:
When [APCO] is “MAN”.
When [APCO] is not “MAN”.
< BCD396T Operation Specification >
[THRESHOLD]
[ERR_RATE]
(AUTO: Auto/MAN: Manual/DFLT: Default/NONE: None)
: APCO Threshold
(0 – 63 )
: Error Rate
(from 0 to 99)
=====================================================================================
<COMMAND WIN>
*Get Window Voltage
=====================================================================================
Controller → Radio
①
WIN[\r]
Radio → Controller
①
WIN,###,[FRQ][\r]
: A/D Value (0-255)
Returns current window voltage and its frequency.
The order of the frequency digits is from 1 GHz digit to 100 Hz digit.
This command is for test mode.
=====================================================================================
<COMMAND BAV>
*Get Battery Voltage
=====================================================================================
Controller → Radio
①
BAV[\r]
Radio → Controller
①
BAV,####[\r]
: A/D Value (0-1023)
Battery Level[V] = (3.2[V] * #### * 2 )/1023
Returns current battery voltage.
This command is for test mode.
CTCSS/DCS CODE LIST
NONE / SEARCH
MODE
NONE
CODE
0
MODE
SEARCH
CODE
127
CODE
64
65
66
67
68
69
70
71
72
73
74
75
MODE
CTCSS 118.8Hz
CTCSS 123.0Hz
CTCSS 127.3Hz
CTCSS 131.8Hz
CTCSS 136.5Hz
CTCSS 141.3Hz
CTCSS 146.2Hz
CTCSS 151.4Hz
CTCSS 156.7Hz
CTCSS 159.8Hz
CTCSS 162.2Hz
CTCSS 165.5Hz
CODE
81
82
83
84
85
86
87
88
89
90
91
92
CTCSS
MODE
CTCSS 67.0Hz
CTCSS 69.3Hz
CTCSS 71.9Hz
CTCSS 74.4Hz
CTCSS 77.0Hz
CTCSS 79.7Hz
CTCSS 82.5Hz
CTCSS 85.4Hz
CTCSS 88.5Hz
CTCSS 91.5Hz
CTCSS 94.8Hz
CTCSS 97.4Hz
215
MODE
CTCSS 183.5Hz
CTCSS 186.2Hz
CTCSS 189.9Hz
CTCSS 192.8Hz
CTCSS 196.6Hz
CTCSS 199.5Hz
CTCSS 203.5Hz
CTCSS 206.5Hz
CTCSS 210.7Hz
CTCSS 218.1Hz
CTCSS 225.7Hz
CTCSS 229.1Hz
CODE
98
99
100
101
102
103
104
105
106
107
108
109
< BCD396T Operation Specification >
CTCSS
CTCSS
CTCSS
CTCSS
CTCSS
100.0Hz
103.5Hz
107.2Hz
110.9Hz
114.8Hz
76
77
78
79
80
CTCSS
CTCSS
CTCSS
CTCSS
CTCSS
167.9Hz
171.3Hz
173.8Hz
177.3Hz
179.9Hz
93
94
95
96
97
CTCSS
CTCSS
CTCSS
CTCSS
233.6Hz
241.8Hz
250.3Hz
254.1Hz
110
111
112
113
DCS
MODE
DCS 023
DCS 025
DCS 026
DCS 031
DCS 032
DCS 036
DCS 043
DCS 047
DCS 051
DCS 053
DCS 054
DCS 065
DCS 071
DCS 072
DCS 073
DCS 074
DCS 114
DCS 115
DCS 116
DCS 122
DCS 125
DCS 131
DCS 132
DCS 134
DCS 143
DCS 145
DCS 152
DCS 155
DCS 156
DCS 162
DCS 165
DCS 172
DCS 174
DCS 205
DCS 212
CODE
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
MODE
DCS 223
DCS 225
DCS 226
DCS 243
DCS 244
DCS 245
DCS 246
DCS 251
DCS 252
DCS 255
DCS 261
DCS 263
DCS 265
DCS 266
DCS 271
DCS 274
DCS 306
DCS 311
DCS 315
DCS 325
DCS 331
DCS 332
DCS 343
DCS 346
DCS 351
DCS 356
DCS 364
DCS 365
DCS 371
DCS 411
DCS 412
DCS 413
DCS 423
DCS 431
DCS 432
216
CODE
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
MODE
DCS 445
DCS 446
DCS 452
DCS 454
DCS 455
DCS 462
DCS 464
DCS 465
DCS 466
DCS 503
DCS 506
DCS 516
DCS 523
DCS 526
DCS 532
DCS 546
DCS 565
DCS 606
DCS 612
DCS 624
DCS 627
DCS 631
DCS 632
DCS 654
DCS 662
DCS 664
DCS 703
DCS 712
DCS 723
DCS 731
DCS 732
DCS 734
DCS 743
DCS 754
CODE
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231