25946 iVector Leaflet_Layout 1 10/05/2013 14:58 Page 2
MYSON
iVECTOR.
A NEW GENERATION OF
INTELLIGENT FAN CONVECTORS
NOW INCLUDING
the iVECTOR 4-pipe
heatingthroughinnovation.
25946 iVector Leaflet_Layout 1 10/05/2013 14:58 Page 3
02
Moder n Heating Solutions
In the UK today, we consume vast quantities of energy in our buildings. For
example, the power we use to heat our homes and provide us with hot water
alone accounts for more than 20% of our national CO2 emissions!
MODERN HEATING
SOLUTIONS.
In today’s world of growing environmental concerns and rising fuel prices it is
clear that the challenge for modern heating solutions is how to provide indoor
comfort in the most energy efficient way possible.
MYSON is one of the oldest and most respected names in the heating industry.
We have been manufacturing fan convectors for over 50 years. As one of the
UK’s leading brands, with a reputation for maximising the role of innovation and
technology in our operations, we are committed to helping reduce national CO2
emissions by developing energy efficient products that are capable of operating
effectively at low flow temperatures.
25946 iVector Leaflet_Layout 1 10/05/2013 14:58 Page 4
Introduction
The iVECTOR.
The iVECTOR is the first in a new generation of intelligent fan convectors.
It has been designed specifically to combine all the traditional advantages of a
fan convector with a range of new product features made possible by our latest
energy efficient heating technology. Overall, the iVECTOR provides an exciting
package of significant benefits:
HIGH OUTPUTS
INTRODUCTION
TO INTELLIGENT
HEATING.
INTELLIGENT CONTROLS
COOLING
SILENT
LOW TEMPERATURE
COMPATIBILITY
SPACE SAVING
03
25946 iVector Leaflet_Layout 1 10/05/2013 14:58 Page 5
04
Efficient & Effective Perfor mance
High outputs
The iVECTOR has a large surface area heat
exchanger. This feature combined with forced
convection from its in-built fan produces high
heat outputs.
EFFICIENT &
EFFECTIVE
PERFORMANCE
Space saving
Due to these high heat outputs, iVECTORs are
much smaller than panel radiators with equivalent
outputs and so take up less wall space.
Silent
Sound levels were a key consideration during the
development stage of the iVECTOR. MYSON are
proud to have now delivered the quietest fan
convector we have ever made, with no compromise
on heat outputs.
Rapid heat
The iVECTOR has a much lower water content than
other heat emitters, such as panel radiators and
underfloor heating. In fact, the water content is less
than 10% of that of a traditional radiator. Its lower
thermal mass means the iVECTOR works quickly
and efficiently.
Style
With its compact size and modern design, the
iVECTOR is a product that delivers indoor comfort
without compromising on style.
Intelligent controls
The iVECTOR has the most advanced controller
that MYSON have ever developed and it is
flexible enough to suit all lifestyle requirements
with both ‘easy’ and ‘full’ operating modes plus
an in-built option to link to a building management
system (BMS).
Low temperature compatibility
The iVECTOR works efficiently with both low
temperature systems, such as heat pumps, and
traditional systems, such as gas/oil-fired boilers.
Easy to install
Due to its solid, one-piece casing the iVECTOR is
extremely easy to install.
Cooling
Not only is the iVECTOR great at heating spaces
but, when connected to a chilled water supply, it can
now rapidly cool spaces as well.
25946 iVector Leaflet_Layout 1 10/05/2013 14:58 Page 6
Efficient & Effective Perfor mance
05
25946 iVector Leaflet_Layout 1 10/05/2013 14:59 Page 7
Intelligent & Easy to Use Controls
The intelligent, electronic control system in every iVECTOR provides a wide
range of easy to use heating and cooling operating options. Its two-tier level of
programming incorporates an ‘easy’ mode for basic operation and a ‘full’ mode
for more advanced functions.
l
Each iVECTOR is individually programmable
l
24/7 programmer with 1 hour time periods
l
Night set-back function
l
Lockable LCD backlit display
l
Option to link to a building management system (BMS)
l
The controller will also automatically select and vary the fan speeds as
INTELLIGENT
& EASY TO USE
CONTROLS.
required, depending on the current room temperature and the required room
temperature set by the user.
All of the features mentioned above are included with every iVECTOR at
no extra cost.
Comfort Mode - Fan Speeds (Winter Heating)
22
Room Temperature (Set at 21°C)
21
20
19
18
17
16
Off
Normal
Medium
Boost
15
14
For more information on the
13
Time ---->
Winter Heating - If the room temperature is 5°C or lower than the set point then the iVECTOR
will activate boost mode, which will ensure the room heats up quickly. When the room is within
5°C of the set point then the iVECTOR will automatically switch to medium until the room
temperature is within 2°C, then the normal fan speed will be selected. The iVECTOR will then
maintain the normal fan speed until the set point has been achieved.
Comfort Mode - Fan Speeds (Summer Cooling)
29
Room Temperature (Set at 21°C)
28
27
26
25
24
23
22
21
Off
Normal
Medium
Boost
20
Time ---->
Summer Cooling - The process is the same as the Winter Heating cycle however the
temperatures will be above the set point rather than below.
iVECTOR’s intelligent and easy
to use controls, watch our video
by scanning the QR code.
06
25946 iVector Leaflet_Layout 1 10/05/2013 14:59 Page 8
Efficient & Effective Perfor mance
07
25946 iVector Leaflet_Layout 1 10/05/2013 14:59 Page 9
08
A Flexible Solution
The iVECTOR is a flexible heating solution. It has been designed to operate
efficiently in a variety of systems and situations. The iVECTOR has a powerful
combination of features that enable it to provide a fast, accurate and
co-ordinated response to the heating requirements of every room in a building.
The iVECTOR has proven to be a popular choice within the commercial sector,
A FLEXIBLE
SOLUTION.
having been installed in a variety of locations, such as schools, universities, care
homes and retail facilities. The iVECTOR has also been installed in special areas
such as a boat house, garden centres and car showrooms.
More flexibility:
l
A cost effective option for use
with both traditional boilers and
renewable heat sources.
l
Easy to install alone or add to an
existing heating system in individual
rooms, as and when required.
l
Operates efficiently alongside other
heat emitters on the same low
water temperature system. For
example, underfloor heating could
be installed on a ground floor and
the iVECTOR on upper floors. It
can also be combined with radiators
and towel warmers in the same
building.
25946 iVector Leaflet_Layout 1 10/05/2013 14:59 Page 10
Low Temperature Compatibility
LOW
TEMPERATURE
COMPATIBILITY.
Both of these products
give the same output
In recent times, gas boilers have overwhelmingly been the UK’s most popular
choice for generating heat in buildings. Today, however, the list of options
is growing, with renewable technologies such as heat pumps becoming
more popular.
Lower water temperatures = greater system efficiencies
Did you know:
l
Heat pumps are at their most
efficient when operating at lower
water
temperatures,
typically
around 35 - 45°C.
l
Underfloor heating is a popular
choice for low water temperature
systems. It can, however, be difficult
to install within retrofit projects.
l
Modern panel radiators are
compatible with low water
temperature systems; however, to
maintain comfort levels existing
radiators may need to be replaced
with larger sizes.
l
The iVECTOR works perfectly with
low water temperature systems. Its
high heat outputs mean that it
is a great, space saving heating
solution.
09
25946 iVector Leaflet_Layout 1 10/05/2013 14:59 Page 11
10
Enhanced Indoor Comfort Control
ENHANCED
INDOOR
COMFORT
CONTROL.
Heating and Cooling Options.
The iVECTOR can be used to enhance indoor comfort during all weather
conditions and in a variety of situations due to its heating and cooling
operational options. Where cooling is required, there are now two models to
choose from - the original 2-pipe iVECTOR and the newly introduced 4-pipe
version which is built with cooling in mind.
Source:
Air / Ground
Winter Mode
2-Pipe Model
A system using 2-pipe iVECTORs can normally be used for either heating or
cooling. For heating purposes, the iVECTORs in a system all need to be
connected to a heat source, i.e. boiler or heat pump, and for cooling operation
they have to be connected to a chiller.
However, if a reverse cycle heat pump is installed in the system then it is possible
for all iVECTORs on the system to either heat or cool, depending on which
cycle the heat pump is in. A key point to note is that both the heated and chilled
water flow through the same 2 pipes, therefore, the entire system must either
be in heating or cooling mode.
The introduction of a 4-pipe iVECTOR provides much more flexibility and
further opportunities for enhanced indoor comfort.
Source:
Air / Ground
Summer Mode
25946 iVector Leaflet_Layout 1 10/05/2013 14:59 Page 12
Enhanced Indoor Comfort Control
4-Pipe Model
The 4-pipe iVECTOR model has two pipes connecting to a heat source and
two pipes connecting to a chiller. This feature enables an enhanced facility for
indoor comfort within a building whereby the iVECTOR can provide both
heating and cooling to different parts of the same building at the same time an extremely useful option when one area is in shade whilst another concurrently
has a sunny aspect i.e. north and south facing aspects.
l
The main difference between the 2 and 4-pipe iVECTOR is that the 4-pipe
iVECTOR has 2 heat exchangers, one for heating and one for cooling.
l
This means that each heat exchanger has its own set of flow and return pipes,
2-Pipe 3/4" BSP Connection
one from a boiler and one from a chiller.
l
Critically this means, from a system design point of view, that if a system has
multiple iVECTORs installed some can be used for heating whilst others can
be used for cooling at the same time.
l
When would this facility be required? A large building may experience
different temperatures in different areas. For example, a south facing façade
will typically be warmer than a north facing one. This means that while heating
may be required on the north side of the building, the south side with its
increased solar gains may require cooling.
l
This means that the iVECTOR allows a system to work to its full flexibility
and buildings can maintain an all-round comfortable temperature throughout
the year.
Note: The 4-pipe iVECTOR will require the 4-pipe valve kit for heating and cooling modes.
4-Pipe 3/4" BSP Connection
11
25946 iVector Leaflet_Layout 1 10/05/2013 14:59 Page 13
12
Technical Data
2-Pipe.
Dimensions.
Model
Nominal Height
(mm)
Depth
(mm)
Length
(mm)
iV60x080
iV60x100
iV60x120
iV60x140
iV60x160
600
600
600
600
600
153
153
153
153
153
800
1000
1200
1400
1600
Sound Levels.
TECHNICAL DATA.
Sound Pressure (dBA) (at 2.5m)
Model
iV60x080
iV60x100
iV60x120
iV60x140
iV60x160
Normal
Medium
Boost
24.8
27
24
24.9
27
37.7
35.8
40.5
35.5
35
47.9
47.9
51.7
54.8
56.3
Sound levels tested in accordance with ISO 3741.
Weight, Water Content and Motor Power.
Flow Rates/Pressure Losses - Heating/Cooling.
Pressure Drop (kPa)
Model
Motor Power
(W)
Water Content
(l)
Unpacked
Weight (kg)
Flow
(l/h)
iV60x080
iV60x100
iV60x120
iV60x140
iV60x160
iV60x080
iV60x100
iV60x120
iV60x140
iV60x160
32
35
44
53
65
0.66
0.92
1.19
1.45
1.72
22.8
27.7
32.5
37.5
42.6
100
150
220
330
500
750
0.7
1.4
2.9
6.1
13
27.5
1
2.1
4.1
8.5
17.8
36.5
1.4
2.9
5.5
11.1
22.9
46.2
1.6
3.2
6.1
12.2
24.9
49.8
1.9
3.7
7.1
14.2
28.7
57.1
Air Flow Rates.
Condition
Heating
Cooling
Air Flow m3/h
Fan
Speed
iV60x080
iV60x100
iV60x120
iV60x140
iV60x160
Normal
Medium
Boost
Normal
Medium
Boost
90
148
247
65
110
202
135
221
370
98
165
302
180
295
493
130
220
403
225
369
616
163
275
504
270
443
740
195
330
605
Performance Data.
Model
iV60x080
iV60x100
iV60x120
iV60x140
iV60x160
Fan
Speed
Normal
Medium
Boost
Normal
Medium
Boost
Normal
Medium
Boost
Normal
Medium
Boost
Normal
Medium
Boost
Heat Output (Watts)
Cooling (Watts)
Flow
(l/h)
ΔT20
ΔT25
ΔT30
ΔT35
ΔT40
ΔT45
ΔT50
341
341
341
450
450
450
600
600
600
700
700
700
800
800
800
738
989
1360
1012
1352
1892
1214
1643
2409
1428
1945
2916
1647
2246
3422
940
1260
1733
1289
1723
2412
1548
2094
3070
1820
2478
3716
2099
2863
4362
1146
1537
2113
1572
2101
2941
1887
2553
3743
2219
3022
4531
2560
3491
5318
1355
1817
2499
1859
2484
3477
2231
3018
4425
2624
3573
5357
3027
4127
6288
1567
2101
2889
2149
2872
4020
2580
3490
5117
3034
4131
6194
3499
4772
7270
1781
2388
3284
2443
3265
4569
2932
3967
5815
3449
4695
7040
3977
5424
8263
1997
2678
3682
2739
3661
5124
3288
4448
6521
3867
5265
7894
4460
6082
9266
For BTUs multiply Watts by 3.412.
Condition 7-12-27
Total
Sensible
707
1126
1648
1011
1600
2304
1520
1960
2918
1490
2320
3533
1729
2679
4147
527
829
1227
753
1178
1716
931
1442
2173
1110
1707
2631
1288
1972
3088
Relative Humidity: Sensible cooling at 50%.
25946 iVector Leaflet_Layout 1 10/05/2013 14:59 Page 14
Technical Data
4-Pipe.
Dimensions.
Sound Levels.
Model
Nominal Height
(mm)
Depth
(mm)
Length
(mm)
Model
iV60x080
iV60x100
iV60x120
iV60x140
iV60x160
600
600
600
600
600
153
153
153
153
153
800
1000
1200
1400
1600
iV60x080
iV60x100
iV60x120
iV60x140
iV60x160
Sound Pressure (dBA) (at 2.5m)
Normal
Medium
Boost
24.8
27
24
24.9
27
37.7
35.8
40.5
35.5
35
47.9
47.9
51.7
54.8
56.3
Sound levels tested in accordance with ISO 3741.
Weight, Water Content and Motor Power.
Flow Rates/Pressure Losses - Cooling.
Water Content (l)
Pressure Drop (kPa)
Model
Motor Power
(W)
Heating
Cooling
Unpacked
Weight (kg)
Flow
(l/h)
iV60x080
iV60x100
iV60x120
iV60x140
iV60x160
iV60x080
iV60x100
iV60x120
iV60x140
iV60x160
32
35
44
53
65
0.33
0.46
0.6
0.73
0.86
0.66
0.92
1.19
1.45
1.72
24.8
30.1
35.3
40.7
46.2
100
150
220
330
500
750
0.7
1.4
2.9
6.1
13
27.5
1
2.1
4.1
8.5
17.8
36.5
1.4
2.9
5.5
11.1
22.9
46.2
1.6
3.2
6.1
12.2
24.9
49.8
1.9
3.7
7.1
14.2
28.7
57.1
Flow Rates/Pressure Losses - Heating.
Pressure Drop (kPa)
Flow
(l/h)
iV60x080
iV60x100
iV60x120
iV60x140
iV60x160
100
150
220
330
500
1.4
2.8
5.8
12.2
26
2
4.2
8.2
17
35.6
2.8
5.8
11
22.2
45.8
3.2
6.4
12.2
24.4
49.8
3.8
7.4
14.2
28.4
57.4
Air Flow Rates.
Condition
Heating
Cooling
Air Flow m3/h
Fan
Speed
iV60x080
iV60x100
iV60x120
iV60x140
iV60x160
Normal
Medium
Boost
Normal
Medium
Boost
90
148
247
65
110
202
135
221
370
98
165
302
180
295
493
130
220
403
225
369
616
163
275
504
270
443
740
195
330
605
Performance Data.
Model
iV60x080
iV60x100
iV60x120
iV60x140
iV60x160
Fan
Speed
Normal
Medium
Boost
Normal
Medium
Boost
Normal
Medium
Boost
Normal
Medium
Boost
Normal
Medium
Boost
Heat Output (Watts)
Cooling (Watts)
Flow
(l/h)
ΔT20
ΔT25
ΔT30
ΔT35
ΔT40
ΔT45
ΔT50
300
300
300
350
350
350
400
400
400
450
450
450
500
500
500
517
692
952
708
946
1324
850
1150
1686
1000
1362
2041
1153
1572
2395
658
882
1213
902
1206
1688
1084
1466
2149
1274
1735
2601
1469
2004
3053
802
1076
1479
1100
1471
2059
1321
1787
2620
1553
2115
3172
1792
2444
3723
949
1272
1749
1301
1739
2334
1562
2113
3098
1837
2501
3750
2119
2889
4402
1097
1471
2022
1504
2010
2814
1806
2443
3582
2124
2892
4336
2449
3340
5089
1247
1672
2299
1710
2286
3198
2052
2777
4071
2414
3287
4928
2784
3797
5784
1398
1875
2577
1917
2563
3587
2302
3114
4565
2707
3686
5526
3122
4257
6486
For BTUs multiply Watts by 3.412.
Condition 7-12-27
Flow (l/h)
Total
Sensible
350
350
350
450
450
450
600
600
600
700
700
700
800
800
800
672
1070
1566
960
1520
2189
1444
1862
2772
1416
2204
3356
1643
2545
3940
501
788
1166
715
1119
1630
884
1370
2064
1055
1622
2499
1224
1873
2934
Relative Humidity: Sensible cooling at 50%.
Electrical Data: All iVECTOR models require an electrical supply of 220-240V 50Hz fused at 3A.
13
25946 iVector Leaflet_Layout 1 10/05/2013 14:58 Page 1
MYSON
MYSON Eastern Avenue, Team Valley, Gateshead, Tyne & Wear NE11 0PG, UK
T: 0845 402 3434, F: 0191 491 7568, sales@myson.co.uk, www.myson.co.uk
01.05.2013
heatingthroughinnovation.