From the MELSEC-A/QnA Series to the
MELSEC-Q Series*
Comprehensive, risk-free upgrade solutions
*This transition guide is also applicable for the
AnS/QnAS Series.
P
Related information
➔ Technical bulletins
➔ Replacement handbooks
P
Convert existing A Series programs
From the MELSEC-A/QnA Series
\ The MELSEC-Q Series
➔ A/QnA → Q conversion support tool
A➞Q
Reuse existing A Series I/O with Q Series
➔ QA extension base unit
➔ QA conversion adapter module
Reuse existing 32-point I/O with Q Series
Complete Support for
A Series Upgrades
➔ Q Series large type base unit/Q Series large type I/O module
Replace A Series modules with AnS equivalents
➔ A-A1S module conversion adapter
Q Series MELSECNET(Ⅱ), MELSECNET/B compatibility
➔ MELSECNET(Ⅱ)-MELSECNET/10 gateway set
➔ AnS (small type) local station dedicated module
➔ MELSECNET/10 network module (Production continues)
Replace Q4ARCPU redundant systems with Q Series
➔ Redundant type extension base unit
Replace MELSECNET/MINI-S3 with CC-Link
➔ A2C shape CC-Link remote I/O module
➔ MELSECNET/MINI-S3 I/O module wiring conversion adapter
Replace A0J2(H) systems with Q Series
➔ A0J2 renewal tool
Upgrade A Series to Q Series while reusing existing wiring
➔ Upgrade tool
Support capabilities
Mitsubishi Electric offers a carefully engineered combination of hardware, software, and
support designed to allow you to upgrade legacy A and QnA Series controller systems to
the current MELSEC-Q Series with the minimum of disruption to your plant operations.
1
➔ Global FA centers
➔ Production discontinuation schedule
➔ Models to be discontinued
➔ Exceptions
Product list
➔ List of products used for upgrade
3
A➞Q
5
MELSOFT
P
9
A➞Q
P 11
A➞Q
P 13
Modification
P 14
Network
P 18
Redundant
system
P 19
CC-Link
P 21
A➞Q
P 23
A➞Q
P 24
Support
P 27
Support
2
At-a-glance technical overviews
Large type A/QnA Series
A/QnA (large type)
A2C Series
A2C
In-depth technical documentation resources
〈Production discontinuation〉
〈Technical bulletin〉
Transition from MELSEC-A/QnA (Large Type) Series to Q Series Handbook
●CPU module
Discontinued
(End of Sep. 2006)
T99-0050
●Fundamentals
L(NA)08043ENG
●I/O module
Discontinued
(End of Sep. 2006)
T99-0050
●Intelligent Function Modules
L(NA)08046ENG
L(NA)08048ENG
L(NA)08050ENG
●Special function module
Discontinued
(End of Sep. 2006)
T99-0050
●Network Modules
●Data link module (MELSECNET(Ⅱ),
●MELSECNET/B module, etc.)
Discontinued
(End of Sep. 2006)
T99-0050
●Communication Modules
●CPU module
Discontinued
(End of Sep. 2006)
T99-0050
●A2C I/O module
End of Sep. 2008
T99-0070
●Special function module etc.
End of Sep. 2008
T99-0070
Transition from MELSEC-A0J2H Series to Q Series Handbook
L(NA)08060ENG
Transition from MELSECNET/MINI-S3, A2C (I/O) to CC-Link Handbook
L(NA)08061ENG
PC interface board
MELSECNET(Ⅱ),
MELSECNET/B
●MELSECNET(Ⅱ), MELSECNET/B
interface board
End of Sep. 2008
T99-0049
L(NA)08062ENG
Small type AnS Series
●Remote I/O module
MELSECNET(Ⅱ),
MELSECNET/B*1
End of Sep. 2008
T99-0049
MELSECNET/MINI-S3
●AnS (small type) master module
End of Sep. 2008
T99-0070
●I/O module
End of Sep. 2008
T99-0070
A0J2(H) Series
A0J2(H)
Transition from MELSEC-I/OLINK to CC-Link/LT Handbook
Transition from MELSEC-A/QnA (Large Type) Series to
AnS/Q2AS (Small Type) Series Handbook
L(NA)08064ENG
Transition of CPUs in MELSEC Redundant System Handbook
(Transition from Q4ARCPU to QnPRHCPU)
L(NA)08117ENG
●CPU module
End of Sep. 2008
T99-0069
●Power supply module
End of Sep. 2008
T99-0069
●I/O module
End of Sep. 2008
T99-0069
●Special function module etc.
End of Sep. 2008
T99-0069
*1:Production of AnS Series master/local station data link modules (A1SJ71AP21, A1SJ71AR21, and A1SJ71AT21B) will be continued.
3
4
Automatic Program Conversion:
GX Developer & Q Conversion Support Tool
Minimize program conversion efforts by using GX Developer's
PLC Type Change function and the Q Conversion Support Tool.
■The Q Conversion Support Tool boosts productivity by avoiding time spent consulting
manuals for guidance on finishing program conversions.
1
Differences between the two programs
■Can be modified directly.
Prevents mistakes and improves efficiency.
Change to Q beforehand
Convert A/QnA programs* to Q programs
with GX Developer's PLC Type Change function.
①
PLC type change
A/QnA program
①
Q program
GX Developer
Original project
Converted project
②
Enter the configuration information on the existing A/QnA special function modules.
③
③
A/QnA → Q conversion support tool
Output
Differences between the two programs and
guidance on how to complete the
conversion are displayed.
〈Image of differences between the two programs〉
HTML conversion
Differences
between two programs
guidance file
①Statement of unconverted devices―#
The original device and the converted device are displayed as shown below. The devices contained in the circuit
block are displayed one line at a time.
#00001 ANI M9201 → SM1255
("#00001" is a search keyword in the HTML conversion guidance file.)
(E.g.)
<See 1 on p. 4.>
<See 2 on pp. 5-6.>
②Statement of unconverted instructions―%
The original instruction and the converted instruction are displayed as shown below. The instructions contained in
the circuit block are displayed one line at a time.
%00001[LRDP K3 D10 D100 K3]→ OUT SM1255
("%00001" is a search keyword in the HTML conversion guidance file.)
(E.g.)
●A list of unconverted instructions and devices
●No need to manually compare the
Point
1
existing program with the converted
program!
Point
2
is displayed.
●Information on recommended products for
unconvertible special function modules is
displayed.
③Statement of special function module processes―!
For the special function module instructions (FROM, DFRO, TO, DTO and instructions using X/Y devices), a message
requesting review is displayed.
(E.g.) !00001 SpeficalFunctionModuleProcess! Refer to ReviewInformation
Note: This support tool applies to ladder programs only.
*A0J2H programs are also supported.
5
("!00001" is a search keyword in the HTML conversion guidance file.)
6
Automatic Program Conversion:
GX Developer & Q Conversion Support Tool
2
HTML conversion guidance file
■Easy comparison of performance specifications before and after replacement.
Detailed information is displayed hierarchically in your web browser. Information on the differences between the two
programs and the conversion guidance file are linked together.
(Example 1) Special function module processes which need to be reviewed
Click "By special function module name" in the
"Programs for special function modules necessary
in review" row.
■Details of unconverted special relays and registers can be displayed, improving conversion
efficiency.
(Example 2) Special relays and registers which are not converted in the Q program
Click the recommended module name
next to "The recommended modules
that can be replaced."
Click "Device no. order" in the
"Special relay/special register
not been converted in PLC
type changing" row.
7
8
For Large Type A/QnA Series
QA Extension Base Unit ( QA65B
)
QA68B
QA Conversion Adapter Module
Reuse existing A Series I/O with a Q Series CPU.
Reuse existing A/QnA extension base units with a
Q Series CPU.
■Protect investment in your existing A Series I/O.
■Mount a QA conversion adapter module to use existing A Series extension base units
with a Q Series CPU.
●The QA6□B extension bases accept existing A Series I/O modules directly. Hence, this permits reuse of an A Series
I/O installation with a Q Series CPU. Use this as the first step towards upgrading an A Series system.
Q Series
Replace the A Series CPU
with a Q Series CPU.
Q Series
Step 1
Step 2
(QA6ADP)
Q Series
extension cable
Entire replacement
with the Q Series
Q Series
extension cable
Replace the main base
unit (A3□B) with the extension
base unit (QA6□B) and
reuse existing modules.
QA extension base used
(QA65B/QA68B)
Large type A Series
extension cable
Existing large type A Series
Q Series
extension cable
Existing large type A power supply,
I/O modules, and other modules can be
utilized; wiring is left as it is.
●Remove the QA extension base unit (QA65B/
QA68B) when all modules have been replaced
with Q Series equivalents.
QA6ADP
●The QA6□B extension base units are compatible with High Performance Model QCPUs only. Basic Model QCPUs,
Process CPUs, Redundant CPUs, Universal Model QCPUs, and Remote I/O Stations are not compatible.
●Please refer to the "QA65B/QA68B Extension Base Unit User's Manual (IB(NA)-0800158)" for details of modules
that can be mounted on the QA6□B extension base units.
Mount the QA conversion
adapter module (QA6ADP) on the
extension base unit (A6□B).
Notes
●The QA6ADP adapter cannot be used with the small type AnS/QnS Series extension base units.
●The QA6ADP adapter is compatible with High Performance Model QCPUs only. Basic Model QCPUs, Process CPUs, Redundant CPUs,
Universal Model QCPUs, and Remote I/O Stations are not compatible.
●Modules which can be mounted on the extension base unit (A6□B) are the same as when QA6□B is used.
●An adapter module mounting bracket is required to mount the QA6ADP adapter. Follow the instructions in the user's manual when mounting.
●When an AC input module is mounted on the "A5□B" extension base unit (without power supply) using the QA6ADP, either the "A6□B with
QA6ADP" or "QA6□B" extension base unit (with power supply) is required in the system.
QA1S65B/QA1S68B Extension Base Unit
・The small type AnS/Q2AS Series modules can also be used by connecting as a QCPU extension base.
・These extension base units can be used with QA65B and QA68B.
■Reduce conversion effort by using the same I/O addressing
When reusing existing modules with a Q Series CPU, it is not required to change the I/O number of the existing
modules. For new module(s) on the main base unit, assign a number after the existing modules in the I/O
assignment settings. This can greatly reduce the program modification time.
■Example of I/O assignment
Replaced
modules (A to Q)
2
3
4
Newly added
modules
5
6
7
8
9
AY41
Empty
Empty
AX41
QA6□B or A6□B
(with QA conversion adapter module)
Replace modules which cannot be mounted with Q Series modules.
Main
base
unit
Type
Point
Address
Intelli.
32 points
100
1 QJ71LP21-25 Intelli.
32 points
120
0 QJ61BT11N
QY41
QX41
Model
QX41
1
QJ71LP21-25
QJ61BT11N
Q06HCPU
AJ71LP21
4
0
AX41
3
AX41
2
AJ61BT11
AX41
A3NCPU
9
1
AY41
Q35B
0
Note: Assign the I/O numbers in the following order: Q Series to A Series or A Series to Q Series.
When the order is mixed (i.e., Q Series → A Series → Q Series), an error will occur in the CPU.
2 QX41
Input
32 points
140
3 QX41
Input
32 points
160
4 QY41
Output
32 points
180
Model
Type
5 AX41 Input
6 AY41 Input
Extension
Empty
base
7
unit
Empty
8
9 AX41 Input
Point
Address
32 points
00
32 points
20
32 points
40
32 points
60
32 points
80
10
Q Series Large Type Base Unit,
Q35BL, Q68BL, Q65BL, Q55BL
I/O Module ( Q38BL,
)
QX11L, QY13L, QY23L, QG69L
Permits Q Series upgrade with existing 32-point I/O wiring.
■Minimize wiring modifications by reusing existing A Series 32-point I/O wiring.
■No need to make new mounting holes. The hole size and pitch of the Q Series large type
base units are the same as those of large type A Series.
■Simple wiring. Just mount the existing wired terminal block on the Q Series large type I/O
module.
QY23L
FUSE
0
A
Q Series large type base unit
L
1
2
3
4
5
6
7
8
L
QX40
Direct mount
9
A
B
MODE
RUN
ERR.
USER
BAT.
BOOT
ER
POW
Q62P
F
FUSE
QY13L
0
L
A
2
L
2
1
3
2
4
4
7
6
8
L
PULL
2
RS-23
8
9
A
B
10
C
D
12
E
14
F
B
18
1
2
20
3
- +
6
24VDC
4mA
A
B
10
12
E
13
14
F
18
19
2
20
3
5
6
24
7
26
9
A
B
30
C
D
32
E
24
COM
25 8
9
26
34
F
36
+ L
QY13
6
L
7
9
9
A
B
11
8
10
C
D
12
E
14
13
F
15
0
16
19
18
2
20
3
22
26
25 8
L
9
28
30
32
E
34
F
24
23 7
31
33
L
3
10
1
2
12
4
14
6
16
3
5
5
7
7
9
18
11
8
9
20
A
B
22
17
C
D
24
19
E
26
L
13
15
F
21
4
21 5
D
32
E
34
F
36
35
28
23
30
25
27
C
TRIA 0/240V
AC10
0.6A
29
3L
32
QY2
34
31
36
33
3
5
7
9
11
13
15
17
19
21
23
The existing wiring
harness plugs in
with no modification
25
27
29
31
33
35
37
38
35
37
38
36
M
35CO
37
38
V
TRIAC
0/240
AC10
0.6A
37
38
0V
AC10
10mA
4
8
27 A
B
28
29 C
30
D
33
6
7
6
22
23 7
31
2
5
4
21 5
27 A
B
28
29 C
8
4
5
3
L
B16 17 1
COM
15 0
6
22
Y
RELA0V 2A
AC24 V 2A
DC24
8
C
11 D
9
4
L
4
5COM
8
9
7
B16 17 1
0
L
2
6
7
6
USB
4
5
3
5
PULL
1
3
1
B
1
3
2
8
0
1
0
1
A
0
A
6
E
QX11L
CPU
Q12H
MELSEC
4
C
D
QY23L
1
2
L
QY23
QX40
L
QX11
Q Series large type I/O modules
- +
24VDC
4mA
・Use existing Q Series power supply and CPU modules without modification.
・Q Series large type I/O modules and existing Q Series modules can be used together (excluding modules which occupy
two slots).
・The upgrade tool (page 23) can also be used. By using the upgrade tool, modules which are not equivalent to Q Series
large type I/O can be mounted without rewiring.
Q Series module
Q Series large type blank cover (QG69L)
(Use when mounting an existing Q Series
module on the large type base unit.)
■Q Series large type I/O module options
Model
Product name
■Q Series large type base unit options
Product name
Model
Outline
Q38BL
8 slots, 1 power supply module required,
Q Series large type I/O module mountable
Q35BL
5 slots, 1 power supply module required,
Q Series large type I/O module mountable
Q68BL
8 slots, 1 power supply module required,
Q Series large type I/O module mountable
Q65BL
5 slots, 1 power supply module required,
Q Series large type I/O module mountable
Q55BL
5 slots, power supply module not required,
Q Series large type I/O module mountable
11
Q Series
large type
module
AX11
QX11L
Outline
32 points; 100 to 120 V AC; rated input current: 10 mA (100 V AC, 60 Hz);
Input module
response time: 15 ms or less (OFF to ON), 25 ms or less (ON to OFF);
32 points/common; 38-point terminal block
Main base unit
Extension base unit
Existing
A Series
module
AY13
QY13L
32-point contact output, 24 V DC/240 V AC, 2 A/point, 5 A/common,
8 points/common, 38-point terminal block
AY23
QY23L
32-point triac output, 100 to 240 V AC, 0.6 A/point, 2.4 A/common,
8 points/common, 38-point terminal block
N/A
QG69L
Blank cover for mounting existing Q Series module on the Q Series large type
base unit
Output module
Large type
blank cover
Note
●The Q Series large type base units and I/O modules are compatible with High Performance Model QCPUs and
MELSECNET/H Remote I/O Stations. Universal Model QCPUs, Basic Model QCPUs, Process CPUs, Redundant CPUs,
and Safety CPU are not compatible.
12
For Large Type A/QnA Series
A-A1S Module Conversion Adapter
: For I/O Modules
( A1ADP-XY
A1ADP-SP: For Special Function Modules )
MELSECNET(Ⅱ)-MELSECNET/10
Gateway Set (Q6KT-NETGW-□□)
Allows use of AnS equivalent modules when A Series
spare parts are not available.
Implement gradual migration from NET(Ⅱ) to NET/10.
■Direct replacement of an A Series module
■Use a Q2AS based NET(Ⅱ)/NET/10 gateway to gradually convert NET(Ⅱ) stations to
NET/10. NET/10 is backwards compatible with the Q Series via NET/H.
Large type A Series base unit
(Example) Partial replacement of MELSECNET(Ⅱ), from large type A Series
programmable controllers to Q Series programmable controllers
●Select an AnS module with equivalent functionality to the A Series
module to be replaced.
Gateway set
●Use the A1ADP adapter to mount the AnS module on the A Series
rack.
Q Series
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NET(Ⅱ) NET/10
Local
Control
station station
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
MELSECNET/10
MELSECNET(Ⅱ)
A-A1S module conversion adapter (A1ADP-□)
Step-by-step replacement with the Q Series
Small type AnS Series I/O modules, special function modules, etc.
A1
A1
A2
■Adding additional I/O to systems with no free slots
A5
A2
MELSECNET
(Ⅱ)
Large type A Series base unit
●Use CC-Link to add additional I/O to systems where
there are no free slots.
A3
●Use an A1ADP adapter to mount an AnS CC-Link
master module on the A Series rack in place of an
I/O module. The removed I/O module can be
duplicated via CC-Link I/O on the network.
A4
【Before transition】
Use a gateway to
incorporate the
Q Series system
into the existing
system.
A-A1S module
conversion adapter
(A1ADP-□)
Small type AnS
Series CC-Link
master module
(A1SJ61BT11)
Q1
Q5
Q2
MELSEC
MELSEC
NET
(Ⅱ) Gateway NET
/10
A3
An
Q3
A Series system
Qn
Q Series system
■Gateway set options
Set model name
NET(Ⅱ)/B part
NET/10 part
Q6KT-NETGW-SS
A1SJ71AP21
A1SJ71QLP21
Q6KT-NETGW-GS
A1SJ71AP21-S3
A1SJ71QLP21
Q6KT-NETGW-RS
Q6KT-NETGW-RB
Main part
A1S35B
A1S61PN
Q2ASCPU
Q6KT-NETGW-TS
Reading
the model
name
Q6KT-NETGW-□□
Gateway set
A1SJ71AR21
A1SJ71AT21B
CC-Link remote
I/O module
●For details of the compatible modules and applicable adapter type, refer to the following documents.
・Technical bulletin: T99-0050-F or later
Q4
Step-by-step
replacement for the
【Transition completed】
entire system conversion
to the Q Series.
Q6KT-NETGW-TB
●Up to three A1ADP adapters per base unit can be used.
Q5
MELSECNET
/H(10)
Q4
【Transitional step】
Please check the cautions and restrictions for the gateway
station network parameters etc. in the related manuals.
13
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NET/10
Normal
station
① ②
A1SJ71QLP21
A1SJ71QBR11
A1SJ71QLP21
A1SJ71QBR11
①Network type:MELSECNET(Ⅱ)
②Network type:MELSECNET/10
S:SI optical fiber cable (double loop)
G:GI-50/125 optical fiber cable (double loop)
R:Coaxial cable (double loop)
T:Twisted pair cable (bus)
S:SI optical fiber cable (double loop)
B:Coaxial cable (bus)
14
MELSECNET(Ⅱ), MELSECNET/B
Local Station Data Link Module
(
A1SJ71AP23Q
A1SJ71AR23Q
A1SJ71AT23BQ
)
Upgraded AnS local station data link modules permit a direct
Q Series connection to existing networks as local stations.
■Replace A Series NET(Ⅱ)/NET/B stations with Q Series systems.
The NET(Ⅱ)/NET/B local station data link modules allow a Q Series system to directly connect to existing
NET(Ⅱ)/NET/B via a QA1S6□B extension base unit.
■Allows gradual Q Series integration into the network while maintaining communications.
Example of a MELSECNET(Ⅱ) configuration incorporating the Q Series
Q Series
PULL
PULL
Master station
MODE
RUN
ERR
USER
BAT
BOOT
POWER
USB
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
High performance model QCPU
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Q Series
extension cable
MELSECNET(Ⅱ)
Local station
(QA1S6□B)
MELSECNET(Ⅱ), MELSECNET/B
Local station data link module
Local station
AnS local station data link module
QA1S6□B extension base unit
Note: Existing versions of this
module cannot be used due to
incompatible firmware.
MELSECNET(Ⅱ)
●Specifications
①Supported CPUs
High Performance Model QCPUs [Q02(H), Q06H, Q12H, and Q25HCPU]
②Compatible extension base units
QA1S6□B or QA6□B with A-A1S module conversion adapter (A1ADP)
③Number of modules per CPU
Send point range can be further increased by mounting up to 6 modules per CPU.
■Local station data link module options
Model
Outline
A1SJ71AP23Q
MELSECNET(Ⅱ)local station data link module for SI optical fiber cable
A1SJ71AR23Q
MELSECNET(Ⅱ)local station data link module for coaxial cable
A1SJ71AT23BQ
④Network parameters
Minimal setup required, as network parameters settings are automatically detected by the module.
⑤Link refresh setting
Link refresh setting is not automatically detected. Hence, FROM/TO instructions within sequence program to
enable send/receive cyclic data are required.
MELSECNET/B local station data link module for shielded twisted pair cable
Sample programs for link refresh are provided in the "A/QnA → Q Conversion Support Tool." The sample
program can be used to create a QCPU program which may reduce development time.
For details, please contact your local Mitsubishi sales office or representative.
15
16
Q Series Options with MELSECNET/10
Network Modules
Redundant Type Extension Base Unit
Complete replacement of NET(Ⅱ) systems with NET/10
while reusing existing cable installations.
Select the best-suited Q Series redundant system
configuration for the application.
■Step-by-step transition to the Q Series system, mixing A Series and Q Series systems.
■Simple upgrades from legacy Q4AR installations to modern Q Series redundant systems.
(Q65WRB)
Since the production of NET/10 modules will continue, this offers further network upgrade options. A complete NET(Ⅱ)
system can be replaced with NET/10 while reusing existing cable installations.
Following this, A Series stations can be replaced by the Q Series as required.
Note: This method does not apply to NET/B systems.
A61RP
A4UCPU
Control system
Redundant CPU
A4UCPU
A61RP
Standby system
Redundant CPU
Tracking cable
Extension cable
A1
A1
A2
A5
A2
MELSECNET
(Ⅱ)
A3
A5
A3
Q3
【Transitional step 1】
(One or more AnU or QnACPU modules
are required as a control station.)
・Change the NET(Ⅱ) master station to the NET/10 control station.
Note: For CPU modules (AnNCPU and AnACPU) that cannot be
set as the NET/10 control stations, please consider
changing to the Q Series.
A5
Configuration options
Q2
MELSECNET
/10
A4
Replace NET(Ⅱ) data link modules at all stations with
NET/10 network modules, and then switch the network
system over to NET/10.
Q1
A2
MELSECNET
/10
A4
【Before transition】
Q1
Q4ARCPU redundant system
・Local I/O system
(with extension base unit)
・MELSECNET/10
PLC to PLC network system
・MELSECNET/10
remote I/O network system
Q5
MELSECNET
/10(H)
A4
Q3
【Transitional step 2】
Local I/O system
(with extension base unit)
Q4
【Transition completed】
An
A Series system
Qn
Q Series system
For stations that are to be changed from A Series
systems to Q Series systems, replace the
programmable controllers to the Q Series, and set
them as NET/10 normal stations.
By gradually transferring the A Series systems to the
Q Series systems, you will be able to complete the
transition to the Q Series system.
・Set the NET(Ⅱ) local stations to the NET/10 normal stations.
Extension cable
Extension base unit for redundant
CPU and power supply systems
Remote I/O network
Controller
network
Control system
Redundant CPU
New!
Redundant type
extension base unit
(Q65WRB)
Redundant power supply
extension base unit
Standby system
Redundant CPU
Control system
Redundant CPU
Tracking cable
Standby system
Redundant CPU
Tracking cable
MELSECNET/H controller network
POWER
Q25HCPU
MODE
QJ71LP21-25
QX42-S1
RUN
ERR
USER
QX42-S1
POWER
QY42P
Q25HCPU
Q12HCPU
MODE
QY42P
QJ71LP21-25
MODE
RUN
RUN
ERR
USER
BAT
BOOT
ERR
USER
BAT
BOOT
QX42-S1
MELSECNET/H remote I/O network
QY42P
QY42P
BAT
BOOT
PULL
PULL
PULL
PULL
PULL
USB
USB
USB
RS-232
RS-232
RS-232
Normal station
Normal station
リモート局
Remote I/O station
Remote I/O station
■Network module options
Product name
Large type A/QnA Series
MELSECNET/10 network module
17
Model
Control/normal station
AJ71BR11
AJ71LP21
AJ71LP21G
AJ71LR21
AJ71QBR11
AJ71QLP21
AJ71QLP21G
AJ71QLP21S
AJ71QLR21
Remote I/O station
AJ72BR15
AJ72LP25
AJ72LP25G
AJ72LR25
AJ72QBR15
AJ72QLP25
AJ72QLP25G
AJ72QLR25
The redundant local I/O system, controller network system, and remote I/O system can be used together in one
system, allowing for a system configuration specific to the application.
■Realizes local I/O system equivalent to Q4ARCPU using the redundant type extension base
unit.
■Up to 63 modules can be mounted using the redundant type extension base unit.
■Fast system switching time at (approx.) 50 ms in the redundant local I/O system,
remarkable improvement compared to the Q4ARCPU redundant system (300 ms + 1 scan
time).
18
A2C Shape CC-Link Remote I/O Module
MELSECNET/MINI-S3 I/O Module
Wiring Conversion Adapter
Replace A2CCPU and NET/MINI-S3 I/O modules with
CC-Link using existing NET/MINI-S3 wiring.
Replace NET/MINI-S3 systems with CC-Link while
reusing existing NET/MINI-S3 wiring.
■The simple replacement process helps minimize the upgrade time.
■Wiring adapter terminal blocks eliminate the need to rewire.
The installation size is the same as that of A2C I/O modules; existing terminal block can be mounted
directly.
(Example) Replacing AJ35TB2-16D with AJ65BTB2-16D using a 34-pin conversion adapter
【Before replacement】
【After replacement】
MELSECNET/MINI-S3 I/O module
(AJ35TB2-16D)
Replace with the CC-Link I/O module (AJ65BTB2-16D)
After replacing
the module,
mount the wired
terminal block.*1
Wiring
conversion
adapter
Remove the terminal block of the
CC-Link I/O module, and then install
the conversion adapter.
Remove the wired
terminal block from
the existing I/O
module.
No modification is necessary
for I/O wiring since the
existing terminal block of the
MELSECNET/MINI-S3 I/O
module can be used.
Rewire the CC-Link cables
and power cables only.
*1:The communication cables and power cables need to be rewired.
■Model list
■Model list
Model to be discontinued
19
Alternative model
Outline
AX41C
AX81C
AJ65DBTB1-32D
Terminal block type, 24 V DC input, 32 points, sink/source
AY51C
AJ65DBTB1-32T1
Terminal block type, 0.5 A transistor output, 32 points, sink
AX40Y50C
AJ65DBTB1-32DT1
AY13C
AJ65DBTB1-32R
AX40Y10C
AJ65DBTB1-32DR
Alternative model
Model to be discontinued
Model
Terminal block type, 24 V DC input, 16 points;
0.5 A transistor output, 16 points, I/O composite module
Terminal block type, relay output, 32 points
Product name
Model
Model
Alternative module
Conversion adapter
AJ35TB1-16D
AJ65BTB1-16D
26-pin conversion adapter*1
A6ADP-1MC16D
AJ35TB2-16D
AJ65BTB2-16D
34-pin conversion adapter*1
A6ADP-2MC16D
Output module AJ35TB1-16T
AJ65BTB1-16T
26-pin conversion adapter*1, *2
A6ADP-1MC16T
Input module
Remarks (restrictions)
*1: The overall size is increased
due to addition of the adapter
to the alternative module.
*2: Additional wiring to CTL+
(External power supply for
output) is required.
Terminal block type, 24 V DC input, 16 points;
relay output, 16 points, I/O composite module
20
A0J2 Renewal Tool
Replace A0J2(H) systems with Q Series using existing
wiring.
■A0J2 renewal tool features
■Structure
The A0J2 renewal tool is used to replace existing A0J2(H) systems with the Q Series. It consists of an interface
module where the existing wired terminal block can be mounted and a base adapter which enables to reutilize the
existing installation holes, etc.
A couple of different installation types are available depending on the available space.
(Example) 2-level stack, stackable type
QX41Y41P
Programmable controller CPU
Mounting plate (for fixing programmable controller)
■Interface module features
Mounting frame (2-level, for stackable type)
The interface module has DC to relay output conversion and AC to DC input conversion functions. Hence, replacement
is possible together with Q Series connector type DC I/O modules.
Dedicated cables are used to connect the interface module to Q Series I/O modules.
Terminal block (for 100/200 V AC relay)
【After replacement】
Interface module(for 24□/28□□)
Interface module(for 56□□)
Shape after assembly
Stackable type
Suitable when there is enough
depth. Stack the programmable
controller on the existing panel
face.
【Before replacement】
Note: Depth of 236 mm or
more is required (when
two interface modules
are stacked).
Base adapter (for 56□□)Large width base adaptor indicates a part of the programmable controller fixing frame set.
■Basic configuration
【After replacement】
【Before replacement】
Flat mounting type
Suitable when there is enough
space above existing modules.
Mount the programmable
controller above the interface
module(s).
Note: Space of 92 mm or
more from the top of the
existing modules is
required.
Q Series programmable controller
A0J2(H) Series programmable controller
・Main base unit(Q33B)
・CPU module
・Power supply module(Q62P)*1
・I/O module
・CPU module
A0J2 renewal tool*3
・Interface module
+ ・Programmable controller fixing frame set*2
・Programmable controller connection cable
・I/O module
*1: The interface modules except for some models require 24 V DC power supply. If the Q62P is not used, provide a
separate external power supply.
*2: Includes a base adapter, mounting plate, mounting frame, terminal block, and wiring cable.
*3: See the following list for the applicable interface module.
■Compatible interface module list
A0J2(H) CPU module
Standalone type
A0J2(H) Series I/O module
Mount the programmable
controller separately.
Note: For the AnS Series,
the standalone type
only.
Model to be discontinued
Product name
Model
Output module
A0J2-E24R
A0J2-E28DR
A0J2-E28DT
For detailed specifications, precautions, and restrictions of the A0J2 renewal tool, please refer to the brochure
(X900707-115) and user's manual. For further information, please contact your local Mitsubishi sales office or
representative.
Note
Previously, this product was introduced as a "A0J2(H) interface terminal."
21
I/O module
A0J2-E56AR
A0J2-E56DR
A0J2-E56DT
Alternative model
Alternative programmable controller I/O module
CC-Link
Q Series*1
AnS Series
A1SY41P
AJ65SBTCF1-32T
QX41Y41P
A1SH42
AJ65SBTCF1-32D
QX41Y41P
+ J65SBTCF1-32T
A1SX41+A1SY41P
A1SH42
AJ65SBTCF1-32D
QX41Y41P
A1SX41+A1SY41P + AJ65SBTCF1-32T
A1SH42
AJ65SBTCF1-32D
QX41Y41P
A1SX41+A1SY41P + AJ65SBTCF1-32T
A1SH42
AJ65SBTCF1-32D
QX41Y41P
A1SX41+A1SY41P + AJ65SBTCF1-32T
A1SH42
AJ65SBTCF1-32D
QX41Y41P
A1SX41+A1SY41P + AJ65SBTCF1-32T
Interface module
SC-A0JQIF24R
SC-A0JQIF28DR
SC-A0JQIF28DT
SC-A0JQIF56AR
SC-A0JQIF56DR
SC-A0JQIF56DT
*1: When replacing with the I/O composite module "QX41Y41P (I/O assignment: 32-point input for the first half and
32-point output for the second half)", it is not required to modify the program.
22
Upgrade Tool
Support Capabilities
Replace A Series systems with Q Series without
extensive I/O rewiring.
■Upgrade tool features
The upgrade tool consists of two parts: a conversion adapter to connect existing wiring of large type A Series I/O
modules to Q Series I/O modules; and a base adapter to mount a Q Series base unit, including a supporting part to
secure the bottom of the conversion adapters.
●Remove the entire large type A Series base unit and mount the base adapter in the same position. The existing
mounting holes for the large type A Series base unit can be used to mount the base adapter, without having to make
new installation holes.
●Mount a Q Series base unit on the base adapter.
Global FA centers
"Mitsubishi Global FA Centers" are located throughout North America, Europe, and Asia to provide local support
for your project no matter where you are located.
North American FA Center
Tianjin FA Center
MITSUBISHI ELECTRIC AUTOMATION, INC.
500 Corporate Woods Parkway, Vernon Hills, IL 60061, USA
Tel: +1-847-478-2100 / Fax: +1-847-478-0327
Area covered: North America, Mexico, Chile, Brazil
MITSUBISHI ELECTRIC AUTOMATION (SHANGHAI) LTD.
TIANJIN OFFICE
B-2-801/802, Youyi Building, No. 50 Youyui Road, Hexi District,
Tianjin 300061, China
Tel: +86-22-2813-1015 / Fax: +86-22-2813-1017
Area covered: China
European FA Center
Beijing FA Center
MITSUBISHI ELECTRIC EUROPE B.V. GERMAN BRANCH
(Industrial Automation Division)
Gothaer Strasse 8, D-40880 Ratingen, Germany
Tel: +49-2102-486-0 / Fax: +49-2102-486-1120
Area covered: Europe
MITSUBISHI ELECTRIC AUTOMATION (SHANGHAI) LTD.
BEIJING OFFICE
Unit 908, 9/F Office Tower 1, Henderson Center,
18 Jianguomennei Avenue, Dongcheng District,
Beijing 100005, China
Tel: +86-10-6518-8830 / Fax: +86-10-6518-8030
Area covered: China
UK FA Center
Guangzhou FA Center
MITSUBISHI ELECTRIC EUROPE B.V. UK BRANCH
(Customer Technology Center)
Travellers Lane, Hartfield, Hertfordshire, AL10 8XB, UK
Tel: +44-1707-276100 / Fax: +44-1707-278695
Area covered: UK, Ireland
MITSUBISHI ELECTRIC AUTOMATION (SHANGHAI) LTD.
GUANGZHOU OFFICE
Rm. 1609, North Tower, The Hub Center,
No. 1068, Xing Gang East Road, Haizhu District,
Guangzhou 510335, China
Tel: +86-20-8923-6713 / Fax: +86-20-8923-6715
Area covered: China
Central and Eastern Europe FA Center
Taiwan FA Center
MITSUBISHI ELECTRIC EUROPE B.V. CZECH BRANCH
Radlická 714/113a,15800 Praha 5, Czech Republic
Tel: +420-251-551-470 / Fax: 420-251-551-471
Area covered: Czech Republic, Poland, Hungary, Slovakia
SETSUYO ENTERPRISE CO., LTD.
6F No. 105 Wu-Kung 3rd RD, Wu-Ku Hsiang, Taipei Hsien,
248, Taiwan
Tel: +886-2-2299-2499 / Fax: +886-2-2299-2509
Area covered: Taiwan
Korean FA Center
ASEAN FA Center
MITSUBISHI ELECTRIC AUTOMATION KOREA CO., LTD.
B1F, 2F, 1480-6, Gayang-Dong, Gangseo-Ku, Seoul,
157-200, Korea
Tel: +82-2-3660-9607 / Fax: +82-2-3664-0475
Area covered: Korea
MITSUBISHI ELECTRIC ASIA PTE, LTD.
307 Alexandra Road #05-01/02 Mitsubishi Electric Building,
Singapore 159943
Tel: +65-6470-2480 / Fax: +65-6476-7439
Area covered: Southeast Asia, India
Hong Kong FA Center
Thailand FA Center
MITSUBISHI ELECTRIC AUTOMATION (HONG KONG) LTD.
10/F, Manulife Tower, 169 Electric Road, North Point,
Hong Kong
Tel: +852-2887-8870 / Fax: +852-2887-7984
Area covered: China
MITSUBISHI ELECTRIC AUTOMATION (THAILAND) CO., LTD.
Bang-Chan Industrial Estate No. 111, Soi Serithai 54,
T.Kannayao, A.Kannayao, Bangkok 10230, Thailand
Tel: +66-2-906-3238 / Fax: +66-2-906-3239
Area covered: Thailand
●Attach the conversion adapters to the Q Series I/O modules. Note that the Q Series I/O configuration must duplicate
that of the A Series.
●Remove the terminal blocks from the existing large type A Series I/O modules and mount the terminal blocks on the
conversion adapters. (The existing wiring can be used without modification.)
Upgrade tool
(Base adapter)
Upgrade tool
(Conversion adapter)
Utilize the existing
wiring of the I/O module.
For detailed specifications, precautions, and restrictions of the upgrade tool, please refer to the
brochure (SAN C033E-04ZA) and user's manual.
For further information, please contact your local Mitsubishi sales office or representative.
Shanghai FA Center
MITSUBISHI ELECTRIC AUTOMATION (SHANGHAI) LTD.
4/F Zhi Fu Plazz, No. 80 Xin Chang Road,
Shanghai 200003, China
Tel: +86-21-6121-2460 / Fax: +86-21-6121-2424
Area covered: China
23
24
Support Capabilities
Exceptions (Models to be continued)
Production discontinuation schedule
2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016
Although most of the large type A/QnA Series products were discontinued in September 2006, production of the
following modules will be continued.
Note: In accordance with the continuation of production, model names may be changed.
Offer repair services (7 years)
Initial product discontinuation
(selected products)
Discontinue repair services
(Sep. 2013)
Discontinue production
(Sep. 2006)
Offer repair services (7 years)
Limited availability of
selected products*
Start accepting
orders (Sep. 2006)
Discontinue production
(Sep. 2008)
Discontinue production
(Sep. 2008)
Model
Product name
Large type A/QnA Series power supply module
Discontinue repair services
(Sep. 2015)
A61PN*
A63P
A61RP
If using power supplies other than the above, please consider switching over to one of the above models.
*A61PN is a replacement of A61P/A61PEU/A61P-UL.
Battery
Offer repair services (7 years)
Discontinuation of
all products
Power supply module
Discontinue repair services
(Sep. 2015)
Product name
Model
Battery
A6BAT
*Limited availability of selected products: Production will be extended until the end of September 2008. Please refer to
the Technical Bulletin (T99-0050) for details.
Note: In accordance with the continuation of production, model names may be changed.
MELSECNET/10 network module
Models to be discontinued
Models to be discontinued
Large type A Series/
Large type QnA Series
Small type AnS
data link module
A0J2(H) Series
Model
Production
discontinuation
●CPU module ●I/O module ●Special function module
●Data link module (MELSECNET(Ⅱ), MELSECNET/B module, etc.)
Discontinued
End of Sep. 2006
●CPU module
Discontinued
End of Sep. 2006
●A2C I/O module ●Special function module etc.
End of Sep. 2008
●MELSECNET(Ⅱ), MELSECNET/B interface board
End of Sep. 2008
A2C Series
PC interface board
Product name
Control/normal station
Large type A/QnA Series
MELSECNET/10 network module
Remote I/O station
●MELSECNET(Ⅱ)(A1SJ71AP21-S3),
MELSECNET/B data link remote I/O module (A1SJ72T25B)
End of Sep. 2008
●MELSECNET/MINI-S3 AnS master module (A1SJ71PT32-S3)
●MELSECNET/MINI-S3 I/O module
End of Sep. 2008
●CPU module ●Power supply module ●I/O module
●Special function module etc.
End of Sep. 2008
AJ71BR11
AJ71LP21
AJ71LP21G
AJ71LR21
AJ71QBR11
AJ71QLP21
AJ71QLP21G
AJ71QLP21S
AJ71QLR21
AJ72BR15
AJ72LP25
AJ72LP25G
AJ72LR25
AJ72QBR15
AJ72QLP25
AJ72QLP25G
AJ72QLR25
Note for AnS/Q2AS Series users
Only the large type A and QnA Series product lines are being discontinued.
The AnS and Q2AS Series will continue.
Note: This excludes certain products such as MELSECNET(Ⅱ), MELSECNET/B remote I/O modules and
MELSECNET/MINI-S3 master modules.
25
26
Product List
List of products used for upgrade
MELSECNET(Ⅱ), MELSECNET/B local station data link module
Extension base unit
Product name
QA(1S) extension
base unit
Model
Outline
QA1S65B
5 slots, for AnS Series modules
QA1S68B
8 slots, for AnS Series modules
QA65B
5 slots, for A Series modules
QA68B
8 slots, for A Series modules
Redundant type
Q65WRB
extension base unit
MELSECNET(Ⅱ)
local station data
link module
MELSECNET/B
local station data
link module
5 slots, for Q Series modules
QA conversion
adapter module
Outline
Model
QA6ADP
For I/O modules
Model
A1ADP-XY
For special function
A1ADP-SP
modules
Outline
Adapter for mounting small type AnS/QnAS Series I/O module on A/QnA
base unit
Model
Q6KT-NETGW-SS
MELSECNET(Ⅱ)MELSECNET/10
gateway set
MELSECNET/BMELSECNET/10
gateway set
27
Outline
A1SJ71AP23Q
MELSECNET
(Ⅱ)local station data link module for SI optical fiber cable
A1SJ71AR23Q
MELSECNET
(Ⅱ)local station data link module for coaxial cable
A1SJ71AT23BQ
MELSECNET/B local station data link module for shielded twisted pair
cable
Outline
A set of A1S35B, A1S61PN, Q2ASCPU, A1SJ71AP21, and A1SJ71QLP21
A set of A1S35B, A1S61PN, Q2ASCPU, A1SJ71AR21, and A1SJ71QLP21
Q6KT-NETGW-RB
A set of A1S35B, A1S61PN, Q2ASCPU, A1SJ71AR21, and A1SJ71QBR11
Q6KT-NETGW-TS
A set of A1S35B, A1S61PN, Q2ASCPU, A1SJ71AT21B, and A1SJ71QLP21
Q6KT-NETGW-TB
A set of A1S35B, A1S61PN, Q2ASCPU, A1SJ71AT21B, and A1SJ71QBR11
Outline
AJ65DBTB1-32D
Input: 32 points, 24 V DC (positive/negative common [sink/source]),
terminal block 1-wire type, response time: 1.5 ms
AJ65DBTB1-32T1
Output: 32 points, 12/24 V DC, 0.5 A transistor output (sink),
terminal block 1-wire type (low leakage current type)
AJ65DBTB1-32DR
Input: 16 points, 24 V DC (positive/negative common [sink/source]),
response time: 10 ms
Output: 16 points, 24 V DC/240 V AC, 2 A relay output,
terminal block 1-wire type
MELSECNET/MINI-CC-Link wiring conversion adapter
Product name
Q6KT-NETGW-GS A set of A1S35B, A1S61PN, Q2ASCPU, A1SJ71AP21-S3, and A1SJ71QLP21
Q6KT-NETGW-RS
Model
Input: 16 points, 24 V DC (positive common [sink]), 1-wire type,
high-speed response, response time: 0.2 ms
Remote I/O module AJ65DBTB1-32DT1
Output: 16 points, 24 V DC, 0.5 A transistor output (sink),
(screw terminal
terminal block 1-wire type
block type)
Output: 32 points, 24 V DC/240 V AC, 2 A relay output,
AJ65DBTB1-32R
terminal block 1-wire type
Adapter for mounting small type AnS/QnAS Series special function module
on A/QnA base unit
MELSECNET(Ⅱ)-MELSECNET/10 gataway set
Product name
Product name
Adapter for connecting large type A/QnA extension base unit as QCPU
extension base
A-A1S module conversion adapter
Product name
Model
A2C shape CC-Link remote I/O module
QA conversion adapter module
Product name
Product name
MELSECNET/
MINI-S3-CC-Link
wiring conversion
adapter
Model
Outline
A6ADP-1MC16D
26-pin conversion adapter, 1-wire type, 16-point input
(with CTL+ terminal), CC-Link module dedicated adapter
A6ADP-1MC16T
26-pin conversion adapter, 1-wire type, 16-point output
(with CTL+ terminal), CC-Link module dedicated adapter
A6ADP-2MC16D
34-pin conversion adapter, 2-wire type, 16-point input,
CC-Link module dedicated adapter
28
MEMO
Product List
Q Series large type base unit
Product name
Model
Outline
Q38BL
8 slots, 1 power supply module required,
Q Series large type I/O module mountable
Q35BL
5 slots, 1 power supply module required,
Q Series large type I/O module mountable
Q68BL
8 slots, 1 power supply module required,
Q Series large type I/O module mountable
Q65BL
5 slots, 1 power supply module required,
Q Series large type I/O module mountable
Q55BL
5 slots, power supply module not required,
Q Series large type I/O module mountable
Main base unit
Extension
base unit
Q Series large type I/O module
Product name
Input module
Model
QX11L
32 points, 100 to 120 V AC, rated input current: 10 mA (100 V AC, 60 Hz),
response time: 15 ms or less (OFF to ON), 25 ms or less (ON to OFF),
32 points/common, 38-point terminal block
QY13L
32-point contact output, 24 V DC/ 240 V AC, 2 A/point, 5 A/common,
8 points/common, 38-point terminal block
QY23L
32-point triac output, 100 to 240 V AC, 0.6 A/point, 2.4 A/common,
8 points/common, 38-point terminal block
QG69L
Blank cover for mounting existing Q Series module on the
Q Series large type base unit
Output module
Large type
blank cover
29
Outline
30
Mitsubishi Programmable Controllers
MELSEC-A/QnA Series Transition Guide
Country/Region Sales office
Tel/Fax
USA
Mitsubishi Electric Automation Inc.
500 Corporate Woods Parkway, Vernon Hills, IL 60061, USA
Tel: +1-847-478-2100
Fax: +1-847-478-0327
Brazil
MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda.
Rua Correia Dias, 184, Edificio Paraiso Trade Center-8 andar Paraiso, Sao Paulo,
SP Brasil
Tel: +55-11-5908-8331
Fax: +55-11-5574-5296
Germany
Mitsubishi Electric Europe B.V. German Branch
Gothaer Strasse 8, D-40880 Ratingen, Germany
Tel: +49-2102-486-0
Fax: +49-2102-486-1120
UK
Mitsubishi Electric Europe B.V. UK Branch
Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, UK
Tel: +44-1707-276100
Fax: +44-1707-278992
Italy
Mitsubishi Electric Europe B.V. Italian Branch
Viale Colleoni 7
1-20041 Agrate Brianza (Milano), Italy
Tel: +39-39-60531
Fax: +39-39-6053312
Spain
Mitsubishi Electric Europe B.V. Spanish Branch
Carretera de Rubi 76-80
E-08190 Sant Cugat del Valles (Barcelona), Spain
Tel: +34-93-565-3131
Fax: +34-93-589-1579
France
Mitsubishi Electric Europe B.V. French Branch
25, Boulevard des Bouvets, F-92741 Nanterre Cedex, France
Tel: +33-1-5568-5568
Fax: +33-1-5568-5757
South Africa
Circuit Breaker Industries Ltd.
Private Bag 2016, ZA-1600 Isando, South Africa
Tel: +27-11-928-2000
Fax: +27-11-392-2354
Hong Kong
Mitsubishi Electric Automation (Hong Kong) Ltd.
10F, Manulife Tower, 169 Electric Road, North Point,
Hong Kong
Tel: +852-2887-8870
Fax: +852-2887-7984
China
Mitsubishi Electric Automation (Shanghai) Ltd.
4F Zhi Fu Plazz, No. 80 Xin Chang Road
Shanghai 200003, China
Tel: +86-21-6120-0808
Fax: +86-21-6121-2444
Taiwan
Setsuyo Enterprise Co., Ltd.
6F, No.105 Wu-Kung 3rd Rd, Wu-Ku Hsiang, Taipei Hsine, Taiwan
Tel: +886-2-2299-2499
Fax: +886-2-2299-2509
Korea
Mitsubishi Electric Automation Korea Co., Ltd.
3F, 1480-6, Gayang-dong, Gangseo-gu, Seoul
157-200, Korea
Tel: +82-2-3660-9552
Fax: +82-2-3664-8372
Singapore
Mitsubishi Electric Asia Pte, Ltd.
307 Alexandra Road #05-01/02,
Mitsubishi Electric Building Singapore 159943
Tel: +65-6470-2460
Fax: +65-6476-7439
Thailand
Mitsubishi Electric Automation (Thailand) Co., Ltd.
Bang-Chan Industrial Estate No.111, Soi Serithai 54,
T. Kannayao, 10230 Thailand
Tel: +66-2-517-1326
Fax: +66-2-906-3239
Indonesia
P.T. Autoteknindo Sumber Makmur
Muara Karang Selatan Block A/Utara No.1 Kav.
No.11, Kawasan Industri/ Pergudangan, Jakarta - Utara 14440, P.O. Box 5045
Jakarta 11050, Indonesia
Tel: +62-21-663-0833
Fax: +62-21-663-0832
India
Messung Systems Pvt., Ltd.
Electronic Sadan NO: III Unit No.15, M.I.D.C. Bhosari, Pune-411026, India
Tel: +91-20-2712-3130
Fax: +91-20-2712-8108
Australia
Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road, Rydalmere, NSW 2116, Australia
Tel: +61-2-9684-7777
Fax: +61-2-9684-7245
HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS: 1-14, YADA-MINAMI 5, HIGASHI-KU, NAGOYA, JAPAN
L(NA)08077E-C 0805(MDOC)
New publication effective May 2008.
Specifications subject to change without notice.