Spa Touchpad Error Messages & Codes
Revision 4.0.2, 18th October 2013
The messages and codes listed here are a combination of error, operational and reminders
Along-side each code is a brief description of its meaning.
Under no circumstances should you use this information to attempt a repair unless properly qualified to do so. We
have provided this information as a reference, and for qualified tradesmen to utilise as required.
Spa technicians – we can provide access to full diagnostic manuals covering these messages & codes, via an app
direct to your Android, iPhone, Windows Phone or Symbian Phone. Please ‘create an account’ on our website and
follow instructions listed in the ‘Trade Pages’ category. Alternatively we can email them to you on request (This feature
and access is only available to spa technicians).
Causes of the most common following spa / hot tub fault codes
Flow/Pressure switch open – dirty filters, blockages, switch failure, low water level, pump failure.
Flow/Pressure switch closed – switch failure, pump relay stuck
Hi-Limit fault – dirty filters, blockage, low flow, sensor fault, failed pump – senor reads 45C+ / 112F+
Temperature sensor fault – sensor failed, low flow
Over heat fault – Same as sensor fault, pump not running, relay failed – sensor reads 38-45C / 100-112F
Spa touchpad messages and codes are listed for various models from the following brands:
Chinese
Hercules
Hurricane
Spa-Tech
in.xe (and in.xe swim spa)
If the code is a ‘Slave’ code, it’s a fault with the slave unit – same error cause as the main unit
AOH or AO2 (swim spa slave)
Prr
or Pr2 (swim spa slave)
OH
or OH2 (swim spa slave)
FLO
or FL2 (swim spa slave)
HL
or HL2 (swim spa slave)
Hr
or Hr2 (swim spa slave)
Lxx
UPL
Er1
(swim spa)
SLA
(swim spa)
LLxx
(swim spa)
LLEr
(swim spa)
StbY
OFF
Fx, FFxx
FSxx
Fdxx, dx
EP 0 or 1
ESxx
Edxx
EExx
Econ
rLY
Spa pack temperature too high
Temperature sensor failure
Over heat 43c
Flow error
Hi-limit 48c
Internal hardware error
Low level software setting
No low level software loaded
Communication between Master & Slave failure
Main touchpad has been connected to the slave unit
Unable to select LL program – reverts to menu – faulty Slave
LL program is not a swim spa config & slave unit detected
Standby mode
30 min all outputs off
Filter cycle frequency per day
Filter cycle start time
Filter duration in hours
Economy mode on/off
Economy mode start time
Economy mode duration in hrs
Economy mode end time
Economy mode set
Stuck relay
in.xm
SP-br
SP-Ot
SP-OH
SP-Hr
SP-in
SP-Fx
rH-Hr
rH-HL
rH-nF
rH-Pr
rH-nC
rH-nH
rH-Id
Px-Er
CP-Er
bL-Er
Fn-Er
Sc-Er
LLxx
Ph- xP
brxx
Incorrect input current set
Spa pack under spa too hot
Over heat – water temp 48c
Internal hardware error
Input voltage too low
Fuse 1-3 blown
Hardware error in in.therm heater
Hi-limit circuit tripped
No flow detected
Regulation temperature sensor failed
Communication error - heater to pack
Not heating – no temp increase detected
No match between heater and pack models
No detection of Pump current draw P1-5-Er
No detection of current change on circ pump
No detection of current change on blower
No detection of current change on fan
System learning error
Low level software setting
Incoming power – number of phases 1-3
Input current setting
in.xm2
rH-Id
Hr
HL
OH
rH-nC
Pr-r
AO-H
SP-in
FL-O
FL-C
Fx
Sc-Er
Fr-Er
Sc
bL
P9
UP-Ld
UPL
No match between heater and pack models
Hardware error detected / stuck relay / thermal fuse
Hi-Limit circuit tripped 50c
Overheat. Water temp at 44.5c
Communication error – heater to pack
Temperature sensor failed
Spa pack under spa too hot
Input voltage too low
No flow detected
Flow switch closed
Fuse blown F1-3
Scan error detected / system learning error
Input power frequency 50/60hz out of range
System scanning – 1st power up
No firmware downloaded into system
Programming firmware into system
No valid low level software uploaded
No valid low level software uploaded
CoLd
OH
HLEr
SEoP
SESH
PSoC
PSoL
PSoH
ToE
CLDN
ECL
CHCL
UTO
PUF
MENU
CANC
SEND
CALB
FPx (1-4)
SIL
FPxd (1-4)
SILd
Temperature approaching zero
Over Heat condition
Hi-limit over heat sensor failure
Temperature sensor open circuit
Temperature sensor short circuit
Pressure switch open circuit with circ pump
Pressure switch open with low spd pump
Pressure switch open with high speed pump
Time out error – system shutdown
Cool down cycle
Energy saving cycle
Air blower Channel clear
User time out
Post use filtration
Menu access
Cancel/discard changes
Save changes
Calibration for temp
Filtration period
Silence period start time
Filter duration
Silence timer duration
M7 messages
- - - or - - - F, - - C, or - CFE or CONFIG ERROR
CrC or CHKSUM FAIL
dr, HEATER MAY BE DRY WILL RETEST SHORTLY
drn, DRAINING
drY, dY, HEATER DRY SERVICE REQD
Ecn, Ec
gFI, GFCI FAILURE
HFL, HL, HTR FLOW LOW
Hot, HOT-CALL SVC
ICE, IC, FREEZE COND
LF, LOW FLOW
OHH, HH, HTR TEMP LMT SERVICE REQD
OHS, OH, SPA TEMP LMT
PHH, PH IS HIGH LOWER PH
PHL, PH IS LOW RAISE PH
Pr, PRIMING MODE TAKES 4 MIN
PSt, PERSIST FAIL
rt9, TEST GFCI
rCA, CHANGE MINERAL CARTRIDGE
rCH, NEW FILTER
rCL, CLEAN FILTER
rCO, CLEAN COVER
rdr, DRAIN WATER
rPH, CHECK PH
rSA, CK SANITIZER
rtC, RTC FAILURE
rtr, TREAT WOOD
SAH, SANITIZER HIGH
SAL, SANITIZER LOW
SbY, STANDBY MODE
SE, STANDARD ECONOMY
SF, SAFETY FAULT
SLP, SL
SnA, SA, SENSOR A SERVICE REQD
Snb, Sb, SENSOR B SERVICE REQD
SnS, Sn
Std, St, STANDARD
StU, STUCK ON
Temperature not available
Temperature not available - priming
Configuration error
Firmware installation failure
Possible inadequate water detected
Indicating pump is on while draining
Inadequate water detected
Economy mode set
Spa could not trip RCD
Substantial difference between sensors
Possible pump stuck on
Potential freeze condition – pumps run
Persistent low flow problem
Overheat – spa shut down
Overheat – spa shut down
pH is high
pH is low
Initial priming mode active
Hardware failure
Reminder – test RCD
Reminder – change Nature 2 cartridge
Reminder – replace filter
Reminder – clean filter
Reminder – clean spa cover
Reminder – drain & refill spa
Reminder – test/adjust chemical levels
Reminder – test/adjust sanitiser levels
Hardware Failure
Reminder – wood retreatment required
Sanitiser level is high
Sanitiser level is low
Spa is in ‘standby’ mode
Spa is in ‘ Standard-Economy’ mode
Suction protection fault
Spa is in ‘sleep’ mode
Sensor A not working
Sensor B not working
Sensors out of balance
Spa is in ‘standard’ mode
Pump appears to be stuck on
Non M7 messages (older controllers)
pd
OH
Flo, Fl
Cool
ICE, IC
Sn1, Sn
Sn3, Sn
ILOC
Ec, Econ
Std, St
Sl, Slp
Power down, on battery back up
Overheat
Flow problem
Spa is 11 degrees below set point
Possible freeze condition
Hi-limit fault
Temperature sensor fault
Interlock fault
Spa is in ‘economy’ mode
Spa is in ‘standard’ mode
Spa is in ‘sleep’ mode
Flashing LED messages
1 flash, 3 second gap
2 flashes, 3 second gap
3 flashes, 3 second gap
4 flashes, 3 second gap
Flash – 1 second on, 1 second off
Flash – briefly OFF once per second
Flash – briefly ON once per second
Hi-limit fault
Pressure switch closed (FLC)
Pressure switch open (FLO)
Temperature sensor fault
Hi-limit, OH
Sensor fault
Pressure switch fault
GCF
-.-.-. and RED heater light
-.-.-. and GREEN heater light
All lights flash
E01
E02
E03
E04
E05
End
Not grounded/earthed correctly
Over temp condition
Water temperature detected below 4 degrees C
Something is wrong with the pump
System Error
No water flow
Water temperature below 4 degrees C
Water temperature too high
Pump fault
System stops after 72 hrs operation. Press ‘Unlock’ 3 secs
OH
Fr
FL
E0
E1
E2
E3
E4
E7
FC
Over temperature
Freeze condition detected
Pressure switch failure
Temperature sensor short circuit
Temperature sensor open circuit
Hi-limit sensor short circuit
Hi-limit sensor open circuit
Flow switch short circuit
Improper electrical connection
Filter cycle in operation
‘TEMP’ flashing
_ _ _ _ flashing
_._._._
____
____
Pressure switch or temperature sensor failed
Hi limit tripped
Pressure switch open circuit
Pressure switch closed circuit (jets operate)
Hi Limit tripped (spa inoperative
Chinese Controllers – Including unknown brands
Water tap icon crossed out
Bell icon & HEAT
Bell icon & ICE
ICE
Bell icon & LD F
Bell icon & LEAK
CLDF
FHL
RPH
RSA
RCL
RT9
RDR
RCO
RTR
Low water level detected
Water temperature above 45c
Water temperature below 5c
Winter mode
Load failure
Faulty wiring detected
Low flow
Temperature difference over 5c – low flow
Reminder – test pH
Reminder – sanitise spa
Reminder – clean the filter
Reminder – test RCD safety switch
Reminder – drain / refill
Reminder – clean spa cover
Reminder – treat / clean spa cabinet
Spa-Tech (used on Oasis)
E1
E2
E3
E4
E5
E6
E8
E9
C
H
HH
PL
Temperature sensor 1 fault
Temperature sensor 2 fault
Heat pump temperature sensor fault
Water level sensor detects insufficient water
Input voltage either too high or too low
Flow switch fault
Heat pump compressor pressure fault
Insufficient water flow
Low water temp below 7c
High temperature hi-limit 43c
Overheat 47c
Panel locked
C-1 Control System – S1 & L1 Touchpads
E0
E1
E2
E3
E4
E5
E6
C
H
HH
CPU is fully loaded or loose cables
Heater temperature sensor fault
Heat pump temperature sensor fault
Environmental temperature sensor fault
Water level sensor detecting insufficient water level
Unmatched power input or voltage fluctuations
Water pressure sensor fault – FLO error
Cold / freeze – water below 7 degrees C
Overheat – water temperature over 43 degrees C
Overheat – water temperature over 45-47 degrees C
COOL
FREEZING
ERR
Anti freezing mode – power off
Anti freezing mode – power on
Temperature sensor probe failure
ESA
ESb
Eob
EHH
EoH
EPL
ECP
EUH
EUo
Elo
CPo
LLL
ICE
Eln
InF
out
Temperature sensor error
Water flow sensor error
Water flow sensor error
Heater error over heat 48 degrees
Heater error over heat 43.5 degrees
Water flow error
Water flow error
High input voltage 280v
High input voltage 260v
Lamp current over limit
Circulation pump current over limit
Low water level
Freeze warning – below 44F / 7C
Auto moisturizing overtime
System is moisturizing
Auto drainage process is running
Other Chinese brands
HEAT
ICE
CLDF
E1, FF
Water pump or tap ICON flashing
Thermometer ICON flashing
Hi-limit over 45c
Water temperature below 5c
Circulation pump problem / flow problem
Temperature sensor failure
Water level too low
Low flow
th1 / 39 or - - - / 39
th2 / 39 or - - - / 39
th2 / “current water temp” or - - - / “current water temp”
OH or HOT
HL
HL / 210
0
FLO or - FLC or - -
Freeze protection – temp under 39F / 4C
Both thermistors detecting below 39F / 4C
Temperature sensor error
Over heat 112 F / 44C
Hi-limit 118 F / 47C
Thermistor short circuit
Electronic failure of touchpad or pcb
Flow switch open circuit
Flow switch closed circuit
imPower Lockout Codes (on numerous variable speed pool pumps)
None
Eeprom load failure
1 blink
Micro processor failure
2 blinks
Under voltage below 180v AC
3 blinks
Temperature – over 100C or under -20C
4 blinks
Over current tripped
5 blinks
Over voltage above 269v AC
6 blinks
Shaft seized
7 blinks
Self check – self testing failed
8 blinks
Motor fault – phase disconnected
10 blinks
Other fault
Imperial Spas
dCP
FC
FLO
Ht
HtS
HtS-OHt
OHt
tS-0-tS
tS-255-Ht-OHt
PS1
PS2
Swift River Spas
No DC power at master relay
Freeze condition under 15 degrees C
No circ pump current draw
Over 43 degrees C
Open hi-limit sensor
Short hi-limit sensor
Overheat 48 degrees C
Open temp sensor
Short temp sensor
Pressure switch closed
Pressure switch open
Class Series
FLO
FLC
Err
Prr
HL
FrE
* * * 3 flashing dots on display
* * * with red LED lit on pcb
0.0 / 32F
H2O
BOO
CLE, CF
SbY
LOC
LocP
LocF
Fxx, Fdxx
dxx, Fdxx, Fsxx
Pxx
Exx, Edxx
Edxx, Esxx
Orxx (2.5-9)
CAL
Flow / pressure switch open circuit
Flow / pressure switch closed circuit
Electronic software error
Regulation temp sensor failure
Hi-limit sensor failure
Possible freeze condition
FLO or FLC
Hi-limit sensor failure
Regulation temp sensor failure
Insufficient water level
Pump 1 boost mode
Reminder – clean filter
Spa is in ‘standby’mode – 1hr shutdown
Touchpad panel keys locked
Touchpad partial lock
Touchpad full lock
Filter cycle duration in hours
Filter cycle start delay in hours
Purge cycle duration in hours
Economy cycle duration in hours
Economy cycle start delay in hours
Over range beyond normal temp limit (not a fault)
Calibration error
Hercules
OH
FLO
ICE
SN1
SN2
Over temperature condition detected
Flow problem
Freeze condition detected
Hi-limit sensor failure
Temperature sensor failure
‘Ready’ & ‘Power’ Logo lights flashing
‘Power’ blue light flashing
‘Ready’ green light flashing
Pressure switch open circuit
Hi limit fault
Temperature sensor fault
‘Ready’ icon flashing
____
=:=:=:=
====
Control sensor open or short circuit
Hi limit
Pressure switch open circuit
Pressure switch closed circuit
F0
F1
F2
F3
F4
L
Open circuit thermistor or 0c detected
Thermostat reading 45c overheat
Mechanical Hi-limit 45c
Thermistor fault
Flame Rollout detected
Heater locked out 2 minutes
Hurricane
PS
SH
OP
LO
HL
OH
FLO
ICE
SN1
SN2
Pressure switch failure
Shorted sensor
Open sensor
Low temp, potential freeze
Hi-limit
Overheat
Flow problem
Freeze condition detected
Hi-limit sensor failure
Temperature sensor failure
FLO
FLC
HL, PrH
Prr
FrEE
Loc
CL
Econ
ECdu
Flon
Fldu
* * * 3 flashing dots on display
* * * with red LED on pcb
0.0 / 32F
Flow / pressure switch open circuit
Flow / pressure switch closed circuit
Hi-limit, OH sensor failure
Regulation temp sensor failure
Possible freeze condition
Touchpad key lock
Current time of day
Economy mode on
Economy cycle duration
Filter cycle turn on
Filter cycle duration in hours
FLO, or FLC
Hi-Limit
Regulation temp sensor failure
OH
COOL
FLO
Hold
HOT
ICE
ICE2
PnL
---Sn1
Sn3
FLO2
PluG
Over Temperature detected
Water temp is 11 degrees below set point
Flow / pressure switch open circuit
Panel buttons pressed to frequently
PCB temperature too high
Freeze protection
Freeze protection
Touchpad – pcb communication error
‘Watchdog’ major fault, spa de-activated
Hi-limit sensor failure
Temperature sensor failure
Shorted flow / pressure switch
Test sensor plug left plugged in after service
Flashing display
00
Damaged temp sensor or heat circuit failure
Memory loss – reset required
Maddox Enterprises, Inc
-40
122
HI
HI / temp display – alternating
J11
J12
PSC
PSO
Flashing ‘heat’ light
Temperature sensor open circuit
Temperature sensor short circuit
Hi-limit fault above 117F / 47C
Over temp above 112F / 44C
Temp sensor plugged in Jack 11 is faulty or dangling
Temp sensor plugged in Jack 12 is faulty or dangling
Pressure switch closed
Pressure switch open
Hi-limit fault on older units – reset with light or pump key
HEF
FEF
BBF
SPL
SPH
Heater failure
Filter failure
Bubble failure
Temp below 0c – Freeze condition
Abnormally high temperature detected
Onga 4352, 4353, 4395
LED 1 flash per second
LED 3 flashes per second
Pressure switch open circuit, insufficient flow
Temperature sensor or pcb fault
Director & Turbo series
LED slow green (2-3 sec interval)
LED fast green (1 sec interval)
LED slow red
LED fast red
Initial prime fail, pressure switch open cct
Pressure switch open beyond initial start
Temperature sensor failed
Hi-limit over temperature cut out
OH
SN
FL
Over heat 110F / 43C
Sensor failure
Flow switch closed
Er
HI
Lo
FC
FL
FL (flashing)
Fr
Topside or control failure or temp sensor not connected
Temp over 44.4C
Temp under 7.2C
Filter cycle
Flow error or pressure switch fail
Pressure switch closed
Freeze protection mode – very low temp detected
E1
E2
E3
E4
E5
Temperature sensor fault
Temperature Protection Sensor Fault (HL)
High Temperature Protection (OT) over 38C
Low Temperature Protection under 20C
No Heating – flow / thermal tripped
LX Series
SN1
SN2
FL1
FL2
COL
ICE
OH
---
Hi-limit sensor failure
Temperature sensor failure
Flow / pressure switch open circuit
Flow / pressure switch closed circuit
Cool condition 11 degrees below set point
Freeze condition detected
Over heat condition
‘Watchdog’ major fault, spa deactivated
In addition to the below error codes, both XS & SV series have a ‘heartbeat’ LED that flashes to indicate the error
condition. On, Off, On, Off is normal. ‘On, On, On, Off, On, On, On, Off’ indicates error 3.
XS series
ER-2
ER-3
ER-4
ER-5
ER-6
ER-7
ER-8
99.9
Heater sensor plug connection fault
Water prime failed, insufficient water
Heater thermal trip, over heat
Over temperature. Sensor reading over 45c
Heater temperature sensor failed
In-pool sensor failed
Controller software fault, stuck heater relay
Temperature sensor failed
SV Series
ER-2
ER-3
ER-4
ER-5
ER-6
ER-8
ER-10
99.9
Heater sensor failed
Water prime failed, insufficient water
Heater thermal trip, over heat
Over temperature. Sensor reading 45c
12v overload – too many LED lights
Stuck heater relay
Over current – excessive power draw
Temperature sensor failed
SV Heat Pump
HEAT PUMP AMB
HEAT PUMP COND
HEAT PUMP FLOW
HEAT PUMP LOW P
HEAT PUMP HIGH P
HEAT PUMP COMP
HEAT PUMP EXCH
Ambient thermistor sensor error
Condenser thermistor sensor error
No water flow detected
Compressor low pressure switch open
Compressor high pressure switch open
Compressor thermal cut out open
Heat exchanger thermal cut out open
Pulsar, 2095 & Intuitive Series
Red/green flashing on two LED’s
Green, Green, or Orange flashing LED
Red/green flashing pump LED
Hi-limit sensor tripped, electronic fault
Insufficient water detected
Insufficient water detected (some models only)
Digital 2000 (stainless steel heater tube with pressure switch)
01
02
03
04
05
06
07
08
09
Stuck touchpad button
Touchpad Communication error
Temperature sensor failure mk2 sensor
Pressure switch closed circuit
Over temperature condition
Heater thermal cut-out overheat
Stuck heater relay
Temperature sensor failure mk1 sensor
Prime failed, pressure switch open circuit
Spa Power 1000 & 2000
01
02
03
04
05
06
07
09
Stuck touchpad button
Touchpad communication error
Temperature sensor failure
Optical water sensor failure
Over temperature condition detected
Heater thermal cut-out overheat
Stuck heater relay
Prime failed, insufficient water detected
Spa Power 400, 500, 600, 601, 750, 800, 1200
Error 1 (H2O or Prime Failed)
Error 3
Error 4
Error 5
Error 6
Error 7
Error 8
Error 9 (Spa Power 800 &1200 only)
Warning 1 (Spa Power 800 & 1200 only)
Ht.d (Spa Power 500 only)
Ht.F (Spa Power 500 only)
Prime failed, insufficient water detected
Stuck touchpad button
Optical water sensor failure
Over temperature condition detected
Heater thermal cut-out overheat
Stuck heater relay
Temperature sensor failure
Clock fault
Temperature sensor failure (pool OR heater)
Heating mode - Demand Heating
Heating mode – Filtration Only Heating
Xcelsior Spa Pool System QX350
Error 1 (H2O/CHE)
Error 3
Error 5
Error 6
Error 7
Error 8
Error 9
Prime failed, insufficient or ‘too pure’ water
Stuck touchpad button
Over temperature condition detected 45c
Pump heater thermal cut out overheat
Stuck heater relay
Temperature sensor failure
Heater control circuit failure
SPSVB Variable Speed Blower
Error 2 (2 LED flashes / beep)
Error 3 (3 LED flashes / beep)
Communication or electronic failure
Stuck touchpad button
EN1 / OH
EN2
Sensor 1 failure
Sensor 2 failure
HE
Red, Green, Yellow LED’s flashing
Temperature sensor failed
Insufficient water detected
ILOC
FLO
FLO2
Hold
HOT
ICE
PnL
Sn1
Sn3
COOL
PLuG
---LOC
Interlock failure
Flashing - flow switch open, solid – closed
Flow switch closed circuit
Touchpad buttons pressed too frequently
PCB temperature too high
Freeze condition detected
Panel – PCB communication error
Hi-limit sensor failure
Temperature sensor failure
water temp 11 degrees below set point
Test sensor plug left plugged in after service
‘Watchdog’ major failure. Spa deactivated
Panel locked
Flashing display
OP or OB
SP or SB
8888
Over heat 110F / 43C
Open probe
Short probe
Voltage spike
T5 Touchpad
oH
Fr
Flo
Er0, Er1
Er2, Er3
Fc
Over heat 48C
Freeze – temp below 4C
Flow switch open circuit
Regulation temperature sensor failure
Hi-limit sensor failure
Filter Cycle
T7 Touchpad
Fr
SOH
HOH
tS
LS
FL
Freeze – temp below 8C
Software Over heat – temp above 45C
Hardware Over heat – hi-limit above 46C
Temperature sensor error
Hi-limit sensor error
Flow switch open circuit
DM Industries
BJ2P
BLO
BUS
CP
CS
F1 or F2
FLO
HC
HILI
HP
ICE
LB
LP
LS
LS=O
LS=S
O3U
P1 or P2
Pb
PS
REL
SS
SS=O
SS=S
Purging notification
Air blower error. Fuse blown or defective blower
Communication error
Circulation / HEET pump fault
Current sensor error
Fuse 1 or fuse 2 blown
Pressure switch open – low flow
Heater error
Hi Limit senses above 112F / 44C
High voltage observed
Water temp below 50F / 10C
Light error
Low voltage observed
Large water sensor error
Large water sensor open circuit
Large water sensor short circuit
Ozonator error
Pump1 or pump 2 error
Power board communication to topside error
Pressure switch closed error
Relay stuck
Small heater sensor error
Small heater sensor open circuit
Small heater sensor short circuit
Portapac SSC
00
‘Heat’ indicator flashing
‘Power’ indicator flashing
SP1 or SP2
Temperature sensor fault
Over temperature sensor fault
Over temperature resettable device tripped out 45 degrees
Blower speed adjustment (do not alter – press ‘Demand’)
Digi-Heat Heaters
nFL
o/t
00
No flow detected, pressure switch open circuit
Over temperature Tripped 45c
Temperature sensor failed