PCRAU0726B
Multi-Split Type Air Conditioners E Series
with DC Inverter Power Control
Cooling Only & Heat Pump [50 Hz]
r
i
a
e
H a r m o ny in th
Connectable to max. 9 indoor units
An 11.2 to 15.5 kW Multi-Split system
Daikin’s Super Multi PLUS E series is connectable to up to 9 indoor units and
offers you a richer choice of indoor units to coordinate with each room décor.
Advanced technology from Daikin has achieved a high COP and low sound
level to suit today’s modern living environment.
• Connectable to max. 9* indoor units
New
Design
* Combination is possible with 15.5 kW class outdoor unit and 2.0 kW class indoor units.
1
that suits large and luxurious houses
Main features of Daikin’s SUPER MULTI PLUS
Wide range of outdoor units
3 models of outdoor units are available in the wide range of
11.2, 14 and 15.5 kW classes. A maximum of 9* indoor units
can be connected.
* Combination is possible with 15.5 kW class outdoor unit and 2.0 kW class indoor units.
Wide variety of indoor units
32 models of indoor units grouped into 7 types (heat pump)—ceiling-mounted
cassette, ceiling-mounted built-in, ceiling-suspended, duct-connected, wall-mounted,
floor-standing, and floor/ceiling-suspended dual types—provide a wide range of
options for interior coordination.
High energy savings
The scroll compressor, DC inverter and DC fan motor technologies realise
energy savings, achieving high COP values.
Quiet operation
Latest technologies and features achieve the quiet sound level of 43 dB (A) during
night quiet mode operation for outdoor units, realising comfortable operation.
Great flexibility in installation
Long piping lengths of 145 m for the 15.5 kW class outdoor unit and simplified
wiring reduce restrictions on the installation position.
2
Wide range of choices
To suit every room in large houses, small shops and small offices, the Super Multi PLUS
E series offers a wide range of indoor and outdoor units.
A wide range of both indoor and outdoor units
Outdoor unit
3 models
11.2 kW, 14 kW, 15.5 kW
The outdoor unit can be selected from three
models for the precise power to suit the size
of house, shop or office.
RMK(X)S112EV1A (11.2 kW)
RMK(X)S140EV1A (14 kW)
RMK(X)S160EV1A (15.5 kW)
Indoor unit
32 models 7 types (heat pump)
A wide range of indoor units includes 32 heat pump models in 7 types and 25 cooling only
models in 5 types. Indoor units can be selected to match each room and preference.
Cooling only
Type
Model name
Rated capacity (kW)
20
2.0
25
2.5
35
3.5
Heat pump
50
5.0
60
6.0
71
7.1
Model name
Rated capacity (kW)
Ceiling-mounted cassette type
FCQ-B
FCQ-B
FFQ-B
FFQ-B
FBQ-B
FBQ-B
FHQ-B
FHQ-B
CDKS-EA
CDXS-EA
(700 mm
width type)
(700 mm
width type)
600 x 600
Ceiling-mounted built-in type
Ceiling-suspended type
Duct-connected type
Wall-mounted type
New
Design
CDKS-C
FDXS-C
(900/1,100 mm
width type)
(900/1,100 mm
width type)
FTKS-D
FTXS-D
FTKS-G
FTXS-G
FTKS-J
FTXS-J
Floor-standing type
FVXS-G
Floor/ceiling-suspended dual type
FLXS-B
FLXS-G
3
20
2.0
25
2.5
35
3.5
50
5.0
60
6.0
71
7.1
A wide variety of stylish indoor units
Ceiling-mounted cassette type
Ceiling-mounted built-in type
Ceiling-suspended type
Duct-connected type
Wall-mounted type
Floor-standing type
Floor/ceiling-suspended dual type
4
Energy efficiency and quiet operation
The Super Multi PLUS E series outdoor units use the latest technologies to realise energy
saving performance and quiet operation.
High Energy Savings
With DC inverter power control the air
conditioner can operate at low capacity
most of the time. This is especially
important at night in a residential situation
when the whole family is at home. DC
inverter power control is able to achieve a
high COP even when multiple indoor units
operate simultaneously for long periods of
time.
During night time
Cooling operation
RMXS160E
Heating operation
Master bedroom 3.5 kW class
Bedroom (1) 2.0 kW class
Bedroom (2) 2.5 kW class
Power consumption 2,040 W Power consumption 2,620 W
COP 3.82
COP 3.55
Quiet operation features that achieve total comfort
Quietness is yet another important feature of Daikin’s Super Multi PLUS E series. To
reduce sound and realise comfortable operation, latest technologies and features are
applied to the outdoor units, achieving the quiet operating sound level of 43 dB (A) in
night quiet mode.
Night quiet mode
Mode 2. Manual mode
Starting time and ending time can be input. (External
control adaptor for outdoor unit, DTA104A61 or
DTA104A62, and a subsequently obtained timer are
necessary.)
Mode 3. Combined mode
Combination of mode 1 and 2 can be used depending
on your needs.
*1. Initial setting. Can be selected from 6, 8 and 10 hours.
*2. Initial setting. Can be selected from 8, 9 and 10 hours.
Load % Capacity %
Set on the outdoor PCB. Time of maximum
temperature is memorised. The low operating mode
will become active 8 hours*1 after the peak
temperature in the daytime, and operation will return
to normal 10 hours*2 after that. The operation sound
level for the night mode can be selected from 49 dB
(A) (Step 1), 46 dB (A) (Step 2) and 43 dB (A) (Step
3).
Mode 1. Automatic mode
Peak in the outdoor temperature
100
Operation sound dB (A)
Mode 1. Automatic mode
Operation sound level selectable
from 3 steps for the night mode
8 hrs
10 hrs
(Initial setting)
50
(Initial setting)
0
52
Night Mode
Step 1 max. - 3dB (A)
(11.2 kW)
Step 1: 49 dB (A)
Step 2 max. - 6dB (A)
(11.2 kW)
Step 2: 46 dB (A)
Step 3 max. - 9dB (A)
(11.2 kW)
Step 3: 43 dB (A)
49
46
43
Night mode starts
8:00
12:00
16:00
20:00
Night mode ends
0:00
4:00
8:00
Notes: • This function is available in setting at site.
• The relationship of outdoor temperature (load) and time shown in the
graph is just an example.
The capacity reduction rate differs depending on the operation sound level
step selected.
5
A collection of cutting-edge technologies
realises efficient and quiet operation.
Improving the high efficiency compressor
to achieve a higher COP
1
5
3
Reluctance DC Scroll Compressor
Overheating losses are reduced by pressurising the area
around the motor, boosting energy saving performance in
conjunction with other features.
High thrust mechanism
By introducing high pressure oil, the
reactive force from the fixed scroll is added
to the internal force, thereby reducing
thrust losses. This results in improved
efficiency and suppressed sound levels.
2
Reluctance
DC motor
4
1
RMK(X)S112E
RMK(X)S140E
RMK(X)S160E
2
>> Powerful magnets
>> Smooth sine wave DC inverter
Use of neodymium magnets in the motor
enables efficient generation of high torque,
reducing the size of the compressor.
Use of an optimised sine wave
smoothes motor rotation, further
improving operating efficiency.
>> Stronger materials
>> Optimal refrigerant configuration
The strength of the casing has been increased
by boosting the internal dome pressure.
Changes to the shape of the spiral and volume
ratio result in optimal refrigerant layout.
Smooth Air Inlet Bell Mouth and Aero Spiral Fan
With the bent
blade edge
These two features work to significantly
reduce sound. Guides are added to the bell
mouth intake to reduce turbulence in the
airflow generated by fan suction. The Aero
Spiral Fan features fan blades with the bent
blade edges, further reducing turbulence.
DC fan motor
Efficiency improved in all areas compared
to conventional AC motors, especially at
low speeds.
DC fan motor structure
Without the bent
blade edge
Escaping eddies are sucked
in by the bent blade edges,
reducing overall turbulence.
DC motor efficiency
(Comparison with a conventional AC motor)
100
Efficiency (%)
3
Sine wave DC inverter
80
DC motor
60
Approx.
20%
increase
40 Approx.
AC motor
40%
20 increase
0
200 300
400 500
600
700 800
900 1000
Note: Data are based on
studies conducted under
controlled conditions at
a Daikin laboratory.
Motor speed (rpm)
4
Super Aero Grille
Refined ventilation mechanism enables further reduction in required fan power.
5
SC heat exchanger
A larger sub-cooled area reduces refrigerant flow sound by making it easer to form
a liquid seal in front of the electrical valve.
6
Design flexibility and easy installation
The Super Multi PLUS E Series is connectable to up to 9 indoor units. While the BP unit and the REFNET
joint make installation simple, long piping length and simplified wiring broaden design flexibility.
As many as 9 indoor units can be connected to a single outdoor unit
Thin refrigerant piping makes handling and connecting easier, resulting in significantly reduced installation time.
For outdoor unit 15.5 kW installation
1
2
3
4
5
6
7
8
>> 8 indoor units for a 14 kW installation
BP unit
9
units
>> 6 indoor units for a 11.2 kW installation
REFNET joint
A BP unit is an innovative
development which allows Super
Multi Plus outdoor units to be
connected to a wide range of
different indoor unit types. A BP
unit has the ability to precisely
vary refrigerant volume to meet
the cooling requirements of
individual room spaces.
3 ports BPMKS967A3
The REFNET joint both
reduces the amount of
work involved in
installation and
increases the reliability
of the system.
Optional REFNET joint:
KHRP26A22T
2 ports BPMKS967A2
Long refrigerant piping
A maximum total piping length of 145 m offers flexibility in the choice of
installation positions for the indoor units, and greatly simplifies system
planning.
Main piping
Piping length for RMK(X)S160E
Total main piping length
Total branch piping length
55 m
90 m
Total main and branch piping length
Branch piping
Max. height
difference
30 m
BP unit
Branch piping
145 m (55 + 90)
BP unit
Note: Refrigerant charge is required. (Chargeless piping length 0 m)
7
Simplified electrical wiring connection
The outdoor unit and the BP units operate from separate single-phase power supplies, so no power supply wiring is needed
between them. The size of the wiring pipe from the outdoor unit to the BP units can be reduced, making installation easier.
Earth leakage circuit breaker
Safety breaker
Outdoor unit
D
transmission line (2 lines)
(Outdoor unit--BP, BP--BP)
Power
supply
30 A
Transmission line (4 lines)
(Indoor unit--BP / including earth wire)
Earth wire
Power
supply
BP unit
(2 ports)
15 A
BP unit
(3 ports)
BP unit
(2 ports)
Earth wire
Safety breaker
Earth leakage circuit breaker
Durable outdoor unit
Space saving
The outdoor unit’s heat exchanger fins are processed using a
special anticorrosion treatment. The surface is covered with a
thin acrylic resin layer to enhance the fins’ resistance to acid
rain and salt corrosion. A hydrophilic film layer also prevents
rust caused by the run off of water droplets. Additional
durability is provided by a rustproof steel sheet on the bottom
of the unit.
A single high-capacity
outdoor unit can drive up to
9 indoor units, making it
powerful enough to aircondition a whole residence.
This powerful unit can be
easily installed on a balcony
with its slimline design,
which measures (H) 1,345 x
(W) 900 x (D) 320 mm.
Hydrophilic film
Aluminium
320 mm
Wide Operation Range
The Super Multi PLUS has the wide operation range required
for commercial-use air-conditioning systems. So even when
the outdoor temperature drops to –5ÝC, cooling operation is
still available if the temperature rises rapidly in a crowded
room.
Corrosion-resistant
acrylic resin
50
Outdoor temperature (°C DB)
Cross section of
anticorrosion-treated fin
900 mm
46°C DB
40
30
20
10
0
-10
-5°C DB
Cooling
Outdoor temperature (°C WB)
Heat exchanger fin
1,345 mm
20
15.5°C WB
10
0
-10
-20
–15°C WB
Heating
8
Centralised Control system
Both Super Multi PLUS and VRV systems are compatible with the Building
Air-Conditioning Control System. This allows Super Multi PLUS and VRV units to be
conveniently operated from the same common controller when the two systems are
installed together in a building.
Central remote controller (option)
64 groups (zones) of indoor units can be controlled individually same as
LCD remote controller.
Central remote controller
DCS302CA61
• Max. 64 groups controllable
• Zone control
• Malfunction code display
Unified on/off controller (option)
16 groups of indoor units can be operated simultaneously/individually.
• Max. 16 groups controllable
• Operating status indication
• Centralised control indication
Unified on/off controller
DCS301BA61
Schedule timer (option)
128 indoor units can be operated on a 7-day programmed schedule.
• Max. 128 indoor units controllable
• The start and stop time for twice a day can be set for the week in a unit of one minute.
Schedule timer
DST301BA61
5-room centralised controller (option)
5 indoor units can be controlled. This is a low cost system which can only
control about on/off.
5-room centralised controller
KRC72
• Max. 5 indoor units controllable
• Contribute to save energy by eliminating turn-off of lamps.
Compatible indoor units
FCQ, FFQ
FBQ
FHQ
Central remote controller*1
Unified on/off controller*1
Schedule timer*1
5-room centralised controller*2
Notes: *1. An interface adaptor (KRP928B2S or DTA112B51) is also required for each indoor unit.
*2. A wiring adaptor (KRP413A1S) is also required for each indoor unit.
9
C(F)DK(X)S
FTK(X)S
FVXS
FLXS
Indoor unit lineup
Cooling only
Type
Model name
Rated
capacity (kW)
20
2.0
25
2.5
35
3.5
Heat pump
50
5.0
60
6.0
71
Model name
20
25
35
50
60
71
7.1
Rated
capacity (kW)
2.0
2.5
3.5
5.0
6.0
7.1
Ceiling-mounted cassette type
FCQ-B
FCQ-B
FFQ-B
FFQ-B
FBQ-B
FBQ-B
FHQ-B
FHQ-B
CDKS-EA
CDXS-EA
(700 mm
width type)
(700 mm
width type)
600 x 600
Ceiling-mounted built-in type
Ceiling-suspended type
Duct-connected type
Wall-mounted type
New
CDKS-C
FDXS-C
(900/1,100 mm
width type)
(900/1,100 mm
width type)
FTKS-D
FTXS-D
FTKS-G
FTXS-G
FTKS-J
FTXS-J
Design
Floor-standing type
FVXS-G
Floor/ceiling-suspended dual type
FLXS-B
FLXS-G
10
Ceiling-mounted cassette (multi flow)
Specially designed for false ceilings—for a smooth, modern interior finish
The ideal air conditioner for installation inside
narrow false ceilings—with only the decoration
panel visible after installation. A simple design
makes it comfortable to the public eye in shops and
small offices in tenant buildings, as well as right at
home in the living rooms with false ceilings found in
multi-storey apartment blocks.
3.5 kW class 5.0 kW class 6.0 kW class 7.1 kW class
Cooling
only
FCQ35BVE
FCQ50BVE
FCQ60BVE
FCQ71BVE
Heat
pump
FCQ35BVE
FCQ50BVE
FCQ60BVE
FCQ71BVE
11
Option
Note: Remote controller
cables not included.
Cables should be
obtained locally.
Option
Signal receiver unit
Note: Wireless remote
controllers and signal
receiver units are sold
as a set.
type
Comfort and quietness
Design flexibility
Three convenient patterns for auto-swing operation
Compact decoration panel
Standard: a swing range of 10 to 65
Draft prevention: a limited swing range of 10 to 40 prevents
airflow from blowing directly onto people.
Soiling prevention: a limited swing range of 30 to 65
prevents ceilings from becoming dirty due to direct airflow.
All models feature a decoration panel with the same compact
size and simple design for easier planning of lighting systems
and harmonising of interior décor.
950 mm
Standard
Draft prevention
Same for
all models
Decoration panel is optional
950 mm
Light and compact main units
The indoor units weigh only
24 kg and require an
installation space with a
height of just 245 mm.
Soiling prevention
Min. 245 mm
High-lift drain pump
Quiet operation
The turbofan was designed using advanced aviation
technology to reduce draft resistance inside the unit,
achieving quiet sound level of 33/29 dB (A) to 35/30 dB (A).
A system provides lift for the drain pump of up to 750 mm
from the ceiling. This is
convenient for
multi-storied buildings, which
750 mm
have a large amount of other
piping and wiring inside the
ceiling.
Diffuser
Installation flexibility
3-dimensional blade
High-ceiling applications
(H/L)
FCQ35
FCQ50
FCQ60
FCQ71
33/29 dB(A)
33/29 dB(A)
35/30 dB(A)
35/30 dB(A)
These models have the power
to provide a comfortable
airflow even with a ceiling
height of up to 3.8 m.
Max. 3.8 m
Optional fresh air intake kit
Optional branch duct chamber
Allows fresh air to be circulated using only the fan for
improved room ventilation. This is useful in buildings where
ventilation fans cannot be installed.
A chamber can be connected to the air conditioner to provide
additional airflow for crowded spaces or areas sensitive to
outside temperatures.
Fresh air intake kit
Air filter
(Outdoor)
Intake duct
Branch duct chamber
Discharge duct
Hood
Discharge panel
Note: The intake duct, hood, air filter, insect screen, fireproof damper, etc. should be
obtained locally if required.
Note: The discharge duct, discharge panel, etc. should be obtained locally if required.
12
Ceiling-mounted cassette (compact
Compact dimensions suitable for the light commercial market
The ideal air conditioner for installation inside
narrow false ceilings—with only the smooth and
simply finished decoration panel visible after
installation. The compact dimensions are suitable
even for the light commercial market as well as for
the living rooms with false ceilings found in multistorey apartment blocks.
600 x 600
2.5 kW class 3.5 kW class 5.0 kW class 6.0 kW class
Cooling
only
FFQ25BV1B
FFQ35BV1B
FFQ50BV1B
FFQ60BV1B
Heat
pump
FFQ25BV1B
FFQ35BV1B
FFQ50BV1B
FFQ60BV1B
13
Option
Note: Remote controller
cables not included.
Cables should be
obtained locally.
Option
Signal receiver unit
Note: Wireless remote
controllers and signal
receiver units are sold
as a set.
multi flow) type
Design flexibility
Comfort and quietness
Designed to fit 600 mm wide ceiling grids
Quiet sound level of only 24.5 dB (A)
575 mm
575 mm
286
mm
act
Comp n panel
io
t
a
r
o
dec
At low fan speeds, the 2.5
kW model produces sound
of only 24.5 dB (A), and
even the 6.0 kW model as
low as 32 dB (A). This is due
to a new spiral hub cover
that reduces internal airflow
resistance.
Spiral hub cover
700 mm
(H/L)
700 mm
FFQ25
FFQ35
FFQ50
FFQ60
29.5/24.5 dB(A)
32/25 dB(A)
36/27 dB(A)
41/32 dB(A)
T-bar grid does not need to be cut.
Ceiling panel
Low draft performance is designed for your comfort.
T-bar
600 mm
0°
600 mm
Even for modules other than 600 x 600, no inspection
opening is required. Maintenance can be performed after
simply removing the grille, because the switchbox is built
into the unit.
Multi-flow system offers a selection of air discharge
patterns that suit all areas.
4-way flow
3-way flow
Horizontal Flow
Less draught
Comfortable across all areas
Conditioned air is distributed Adjustable airflow angle to
evenly by Auto-swing
suit all room conditions.
operation.
0°
0°
Auto-swing
between 0° and 60°
60°
Draft
prevention
setting
(Set on site)
" " denotes piping direction. "
outlet (option).
4 patterns
1 pattern
" denotes sealing member for air discharge
Note: For 3-way or 2-way flow installation, the sealing member for air
discharge outlet (option) must be used to close off the unused outlet(s).
5 direction
AUTO-SWING
2-way flow
Standard
setting
1 pattern
0°
Setting to
prevent
soiling of
ceiling
(Set on site)
60°
Settable to 5 different levels
between 0° and 60°
0°
0°
35°
Auto-swing
between 0° and 35°
25°
60°
Auto-swing
between 25° and 60°
35°
25°
60°
Settable to 5 different levels
between 0° and 35°
Settable to 5 different levels
between 25° and 60°
Note: Angles shown above are provided as a guide. They may differ depending on the installation site.
14
Ceiling-mounted built-in type
Flexible air discharge unit to fit various forms of space
This ceiling-mounted built-in air conditioner
is highly flexible in installation. The visible
part is small, with a simple finish that
blends in with any type of room.
6.0 kW class
7.1 kW class
Cooling
only
FBQ60BV1
FBQ71BV1
Heat
pump
FBQ60BV1
FBQ71BV1
15
Option
Note: Remote controller
cables not included.
Cables should be
obtained locally.
Installation flexibility
Meets diverse installation needs
The indoor unit can be installed in rooms with as little as 350 mm between the drop ceiling and ceiling slab. It also works with
both flexible and ordinary ducts.
Standard installation examples
In crawl space
6
With canvas bellows and air intake panel (sold separately)
2 Air conditioner
4
2 Air conditioner
350 mm or more
4
6
5
Air blow
Air intake
425 mm or more
Long-life filter
1
Long-life filter
3
5
1
Air intake
Air blow
45 mm
With high-efficiency filter
Ceiling return
Options
1
2 Air conditioner
2 Air conditioner
4
13
6
540 mm or more
7
2
450 mm or more
4
6
Air intake
Long-life filter
8
5
5
1
Air blow
Air intake
Air blow
3
4
3
5
6
7
Ceiling return with high-efficiency filter
With ordinary ducts
8
9
2 Air conditioner
6
4
9
540 mm or more
Air intake
7
Ordinary duct
(procured locally)
10
11
Ordinary duct
(procured locally)
Air conditioner
460 mm or more
9
8
8
5
Air intake
Air blow
10
11
12
13
Decoration panel
Air discharge opening adaptor
Canvas bellows and air intake panel
Flexible duct
Air discharge grille
Air discharge chamber
High-performance filter
Inspection panel
Rear intake blocking pad
Air discharge opening flange
Rear intake filter chamber
Branch duct
Low-draft filter chamber
Air blow
Flexibly adapts to room interiors
To cope with the challenges of
L-shaped or U-shaped spaces, it is
possible to install the air discharge unit
away from the main unit. This extends
the possibilities for coping with human
gathering patterns or sun lighting. At
the same time, different types of
architectural space can be kept
comfortable.
Provided with drain water lift-up
mechanism as standard equipment
Drainage pipes can be run as high as
250 mm above the drain outlet.
High-efficiency filter (option)
Available in two types: 65% and 90%
colourimetry. This filter easily meets
dust collection efficiency regulations
specified in building codes.
Air discharge opening adaptor
Air
discharge
chamber
250 mm
Canvas bellows
and air intake panel
L-shaped room
U-shaped room
Flexible duct
Flexible duct
(dia. 200 mm)
(dia. 150 mm)
Decoration panel
Branch duct
Air
discharge
grille
Long room
Comfort and quietness
Quiet operation
(H/L)
Comfort
FBQ60and quietness
41/35 dB(A)
FBQ71
41/35 dB(A)
16
Ceiling-suspended type
Slim body with quiet and wide airflow
This ceiling-suspended type air conditioner features
a slim body with a quiet and wide airflow.
Cooling
only
Heat
pump
17
3.5 kW class
5.0 kW class
6.0 kW class
FHQ35BVV1B
FHQ50BVV1B
FHQ60BVV1B
FHQ35BVV1B
FHQ50BVV1B
FHQ60BVV1B
Option
Note: Remote controller
cables not included.
Cables should be
obtained locally.
Option
Signal receiver unit
Note: Wireless remote
controllers and signal
receiver units are sold
as a set.
Comfort and quietness
Design and installation flexibility
Spreads comfortable air throughout the room
Easier installation for greater freedom of design
Auto-swing for comfort in all directions.
Uniform height and depth. Narrower design for small-capacity
models to meet tighter dimensional constraints.
(mm)
Wide air discharge openings
produce a spreading 100° airflow
Indoor unit
FHQ35
FHQ50
Height
Width
100°
Depth
FHQ60
195
960
1,160
680
Installable on ceilings 3.5 m high
Drain pump kit (option) can be easily incorporated
Drain pipe connection can be done inside the unit. Refrigerant
and drain pipe outlets are at the same opening.
Quiet operation
Quiet operation has been emphasised even more on the
exposed ceiling suspended type unit.
FHQ35
FHQ50
FHQ60
37/32 dB(A)
38/33 dB(A)
39/33 dB(A)
Uses quiet stream fan and
other quiet technologies.
600 mm
(H/L)
Drain pump kit (built inside main unit)
Sound damper
Turbulent flow Straightening
is produced
vane
Quiet
stream fan
Easier to maintain
Long-life filter lasts about 1 year*
Maintenance not required
* For dust concentration of 0.15 mg/m3
Non-dew flap without bristles
Absence of bristles minimises clinging dirt and simplifies
cleaning.
Two time settings (2500 hrs and 1250 hrs) are available to
match the installation environment. Maintenance time
warning is displayed on the remote controller (filter sign).
Non-dew flap
Easy-clean, flat surfaces
It is easy to wipe dirt off the flat side and lower surfaces of the
unit.
18
Duct-connected type
Slim and smooth design suits your shallow ceiling
The visible parts have a smooth and
sophisticated finish that blends with any
type of interior décor. A wireless remote
controller is a standard feature, offering
you great convenience.
700 mm width type
900/1,100 mm width type
2.5 kW class 3.5 kW class
Cooling
only
Heat
pump
19
2.5 kW class 3.5 kW class 5.0 kW class 6.0 kW class
CDKS25EAVMA CDKS35EAVMA
Cooling
only
CDKS25CVMA CDKS35CVMA CDKS50CVMA CDKS60CVMA
CDXS25EAVMA CDXS35EAVMA
Heat
pump
FDXS25CVMA FDXS35CVMA FDXS50CVMA FDXS60CVMA
Option
Installation flexibility
Slim and compact design
Models in the CDKS-EA and CDXS-EA series are only 700 mm in width and 21 kg in weight, so are easily installed in limited
spaces. Just 200 mm in height, all models can be installed in rooms with as little as 240 mm depth between the drop ceiling and
ceiling slab, making them ideal for even shallow ceilings.
240 mm
CDKS-EA
CDXS-EA
More
compact
Signals from the wireless remote controller
are transmitted to the signal receiver.
200 mm
Only 700 mm
Comfort and quietness
CDKS-C
FDXS-C
Quiet operation
Quiet operation sound level of only 29 dB (A) is achieved.
(H/L/SL)
CDKS25
C(F)DXS25
200 mm
900 mm
CDKS35
C(F)DXS35
CDKS50
FDXS50
CDKS60
FDXS60
35/31/29 dB(A) 35/31/29 dB(A) 37/33/31 dB(A) 38/34/32 dB(A)
Home Leave Operation
* Width for the CDKS60C and FDXS60C models is 1,100 mm.
Home Leave Operation prevents large rises or falls in the
indoor temperature by continuing operation* while you are
sleeping or out of your home. This means that an airconditioned welcome awaits when you wake or return. It also
means that the indoor temperature can quickly return to your
favourite comfort setting.
CDKS25EA CDKS35EA CDKS25C CDKS35C
CDXS25EA CDXS35EA FDXS25C FDXS35C
Dimensions (H x W x D) 200 x 700 x 620 mm
200 x 900 x 620 mm
Weight
21 kg
25 kg
3
3
3
Airflow rate (H)
8.7 m /min
9.5 m /min 10 m /min
External static pressure
30 Pa
40 Pa
* Home Leave Operation can be selected for any temperature from 18 to
32ÝC for cooling operation and 10 to 30ÝC for heating operation.
* Locally obtained parts
Air discharge
duct*
Suspension bolt*
Suction duct*
Air filter
Air discharge
grille*
Option
AIR
Suction grille (KDGF19A45)
Chamber
Signal receiver wire
Length = 1,900 mm
Air suction
grille*
Signal
receiver
AIR
Notes: 1. To prevent an increase in operation noise, avoid installing the air suction grille directly below the suction chamber.
2. Grilles, piping connections, ducts, and installation parts should be obtained locally. Duct-connected types do not have drain-up pumps.
3. The signal receiver unit must be located near the air suction inlet, because the unit includes a sensor that detects room temperature.
20
Wall-mounted type
Stylish flat panel harmonises with your interior décor
The simple and sophisticated flat panel design coordinates smoothly with any type of interior
décor. Its refined design and functions provide you with the comfortable living environment you
would like.
GOOD DESIGN
AWARD 2004
IN JAPAN
2.0 kW class
2.5 kW class
3.5 kW class
Cooling
only
FTKS20DVMA FTKS25GVMA FTKS35GVMA
Heat
pump
FTXS20DVMA FTXS25GVMA FTXS35GVMA
Option
New
Design
5.0 kW class
6.0 kW class
Cooling
only
7.1 kW class
FTKS50JVMA
FTKS60JVMA FTKS71JVMA
Heat
pump
FTXS50JVMA
FTXS60JVMA FTXS71JVMA
Option
GOOD DESIGN
AWARD
IN JAPAN
21
The "Good Design Award" is Japan's only synthetic design evaluation/recommendation system and is sponsored by
the Japan Industrial Design Promotion Organization.
Comfort and quietness
Versatile remote control
Quiet operation
The remote controller with a backlit liquid crystal display and
luminescent control buttons also features a built-in Weekly
Timer that can be programmed to suit your personal lifestyle,
with up to four actions per day for each day of the week.
This controller not only allows you to programme on and off
times, but also the desired temperature during those times.
Furthermore, the ‘copy’ function enables any daily programme
to be replicated on any other day or days as required. Correct
programming of the unit may also result in considerable
energy savings.
Wall-mounted type indoor units achieve quiet sound level of
22 dB (A).
(H/L/SL)
FTKS20/25
FTKS35
FTKS50
FTKS60
FTKS71
37/25/22 dB(A) 38/26/23 dB(A) 44/35/32 dB(A) 45/36/33 dB(A) 46/37/34 dB(A)
Intelligent Eye
Intelligent Eye with its infrared sensor automatically controls
air conditioner operation according to human movement in a
room. When there is no movement, it adjusts the temperature
by 2ÝC for energy savings of up to 20% for cooling operation
and 30% for heating operation.
* This function is available for FTK(X)S50/60/71.
The LCD
panel with
backlight
Weekly Timer
operation button
A luminescent
material is
used for the
buttons on the
surface.
When you go out
When you are in the room
Clean air
Comfort Airflow Mode
Comfort Airflow Mode prevents uncomfortable drafts from
blowing directly on to your body. With this function, when you
press the COMFORT button during cooling operation, the flap
moves upward to prevent direct cold drafts. During heating
operation, it also moves downward to prevent direct drafts
and deliver warm air to the floor.
Titanium Apatite Photocatalytic Air-Purifying Filter
* This function is available for FTK(X)S50/60/71.
Air filter
Catches dust
Cooling operation
Heating operation
Titanium Apatite
Photocatalytic
Air-purifying Filter
Econo Mode
Econo Mode reduces the maximum running current and the
maximum power consumption of the outdoor unit to the rated
values. This is useful when using multiple air conditioners and
other electrical devices at the same time.
Running current and power consumption
Maximum
Normal
operation
Rated
Maximum during
normal operation
These filters are not medical devices. Benefits such as the adsorption and
decomposition of bacteria and viruses are only effective for substances that
are collected on and in direct contact with the Titanium Apatite Photocatalytic
Air-Purifying Filter.
Maximum during
Econo Mode
Bacteria Removal Test
Testing method: dropping method
Result certificate: No. 012553-1 and 012553-2
Testing organisation: Japan Spinners Inspecting Foundation
Econo
Mode
From start-up until set temperature is reached
Titanium apatite is a photocatalytic material with high
adsorption power. Besides mould and odours, titanium apatite
also effectively adsorbs and decomposes bacteria and viruses
across its entire surface. The photocatalyst is activated simply
by exposure to light.
Time
• This diagram is a representation for illustrative purposes only.
• Maximum capacity decreases during Econo Mode, requiring more time to reach the set temperature.
22
Floor-standing type
Dual discharges to distribute warm air across the whole floor
A space-saving air-conditioner of simple and neat
appearance suitable for installation virtually
anywhere you like in a room. It realises airflow to
the furthest corners with efficient Vertical AutoSwing and Wide-Angle Louvres.
Heat
pump
23
2.5 kW class
3.5 kW class
5.0 kW class
FVXS25GV1A
FVXS35GV1A
FVXS50GV1A
Dual air discharge for
enhanced comfort
Daikin’s inverter floor standing split systems are especially
effective in heating. The unit features dual air outlets that
diffuse warm, cosy air at low floor level—where you need it
most in winter. This, combined with the vertical auto swing
louvres on the top air outlet, provides uniform distribution of
heated air in the room.
Once winter is over, the lower air outlet can be shut off,
leaving the top air diffuser to stream cool refreshing air
upwards, allowing you to enjoy a cool, comfortable summer.
Stylish and compact flat panel
The clever construction of the elegant flat panel unit allows
the flexibility of fully exposed installation against a wall or
semi-recessed installation in spaces such as in a
mantelpiece.
Double airflow keeps feet warm during heating operation.
Easier cleaning
Versatile remote control
The flat panel design makes cleaning the front face of the
unit a breeze. Surface dust can be simply wiped away with a
soft cloth. Furthermore, the unit can be installed off the floor
to allow for cleaning of the floor space under the unit.
Wiping clean the flat panel is a breeze.
Easily clean beneath the unit.
Weekly Timer
operation button
Clean air
3D air filter catches dust.
The remote controller with a backlit liquid crystal display and
luminescent control buttons also features a built-in Weekly
Timer that can be programmed to suit your personal lifestyle,
with up to four actions per day for each day of the week.
This controller not only allows you to programme on and off
times, but also the desired temperature during those times.
Furthermore, the ‘copy’ function enables any daily
programme to be replicated on any other day or days as
required. Correct programming of the unit may also result in
considerable energy savings.
Titanium apatite photocatalytic
air-purifying filter
Internal structure
Uses a Titanium Apatite Photocatalytic Air-Purifying Filter.
Titanium apatite is a photocatalytic material with high
adsorption power. It effectively adsorbs and removes
bacteria and viruses along with mould and odours.
These filters are not medical devices. Benefits such as the adsorption and
decomposition of bacteria and viruses are only effective for substances that
are collected on and in direct contact with the Titanium Apatite Photocatalytic
Air-Purifying Filter.
Bacteria Removal Test
Testing method: dropping method
Result certificate: No. 012553-1 and 012553-2
Testing organisation: Japan Spinners Inspecting Foundation
24
Floor/ceiling-suspended dual type
Floor/ceiling dual use maximises free space
Two-way installation
The floor/ceiling-suspended dual type’s slim,
rounded design allows both ceiling-suspended and
floor-level installation. Ceiling-suspended
installation frees up wall and floor space, while
floor-level installation is possible without loss of
warm air.
2.5 kW class
Heat
pump
3.5 kW class
5.0 kW class
6.0 kW class
FLXS25BVMA FLXS35GVMA FLXS50GVMA FLXS60GVMA
Ceiling-suspended installation
25
Floor-level installation
Comfort and quietness
Design and installation flexibility
Comfortable airflow
Slim and attractive indoor unit
Vertical Auto-Swing and Wide-Angle Louvres realise that
comfortable airflow spreads throughout a large room. With
these functions, the whole room can be evenly air-conditioned
from either a floor-level or ceiling-suspended installation. The
louvres can be adjusted by hand.
The curved design of the indoor unit merges smoothly with
the wall or floor to enhance the décor of any room.
Compact and lightweight indoor unit
490 mm
The indoor unit is only 490 mm in depth and weighs
a featherlight 16 kg, which means it can be quickly and
efficiently installed by one person.
1,050 mm
200 mm
Clean air
Photocatalytic Deodorising Filter
The Photocatalytic Deodorising Filter is able to decompose
odours and even removes bacteria and viruses. This filter can
be used indefinitely if regular maintenance is carried out.
The Vertical Auto-Swing and Wide-Angle Louvres direct warm/cool air
to every corner of your room.
Quiet operation
Bacteria Removal Test
Testing method: dropping method
Result certificate: No. 298081197-003
Virus Removal Test
Testing method: washout method
Result certificate: No. 298081197-004
Testing organisation: Japan Food Research Laboratories
The floor/ceiling-suspended dual type indoor units achieve
quiet sound level of 28 dB (A).
(H/L/SL)
FLXS25
FLXS35
FLXS50
FLXS60
37/31/28 dB(A) 38/32/29 dB(A) 47/39/36 dB(A) 48/41/39 dB(A)
During cooling operation
Air-Purifying Filter
The filter removes bacteria and viruses, and impurities such as
dust, pollen and cigarette smoke from the air. Its removal rate
for bacteria and viruses has been measured and verified by
the Japan Food Research Laboratories.
Bacteria Removal Testing
Measurement method: dropping method. Test result certificate number
298051308-001
Virus Removal Testing
Measurement method: washout method. Test result certificate number
298051308-002
These filters are not medical devices. Benefits such as the adsorption and
decomposition of bacteria and viruses are only effective for substances that are
collected on and in direct contact with the Photocatalytic Deodorising Filter or
Air-Purifying Filter.
26
Function list
Models
Ceiling-mounted cassette type
Functions
FCQ
Power-airflow dual flaps
Wide-angle louvres
Comfortable
airflow
Vertical auto-swing (up and down)
Horizontal auto-swing (left and right)
3-D airflow
Comfort airflow mode
Indoor unit quiet operation
Night quiet mode
Intelligent eye
Automatic operation (Heat pump only)
Comfort control
Programme dry function
Auto fan speed
Hot-start function (Heat pump only)
Quick warming function (Heat pump only)
Automatic defrosting (Heat pump only)
Inverter powerful operation
Econo mode
Lifestyle
convenience
Home leave operation
Indoor unit on/off switch
Signal reception indicator
Titanium apatite photocatalytic air-purifying filter
Photocatalytic deodorising filter
Air-purifying filter
Mould-proof air filter
Cleanliness
Long-life air filter
High-efficiency filter kit (option)
Fresh air intake kit (option)
Mould-proof operation
Wipe-clean flat panel
Filter cleaning indicator
24-hour on/off timer
Timers
72-hour on/off timer
Weekly timer
Night set mode
Auto-restart after power failure
Worry free
Self-diagnosis with digital display
Anticorrosion treatment of outdoor heat exchanger fins
High-ceiling application
Flexibility
Flexible voltage correspondence
Drain water lift-up mechanism
Ceiling soiling prevention
27
FFQ
Ceiling-mounted built-in type
Ceiling-suspended type
FBQ
FHQ
Indoor unit
Duct-connected type
Outdoor unit
Wall-mounted type
Floor-standing type
Floor/ceiling-suspended dual type
FVXS
FLXS
New
Design
CDK(X)S/FDXS
FTK(X)S20-35
FTK(X)S50-71
New
New
New
28
Specifications
Outdoor unit
Outdoor unit
Cooling only
Model name
RMKS112EV1A
RMKS140EV1A
Power supply
Heat pump
RMXS112EV1A
RMKS160EV1A
RMXS140EV1A
RMXS160EV1A
1 phase, 220-240 V, 50 Hz
Cooling
Capacity (rated)
11.2
14.0
15.5
11.2
14.0
15.5
—
—
—
12.5
16.0
17.5
5.5 to 14.5
7.0 to 18.2
8.0 to 20.8
5.5 to 14.5
7.0 to 18.2
8.0 to 20.8
6
8
9
6
8
9
3.0
3.5
kW
Heating
Total indoor unit capacity
kW
Number of indoor units to be connected
Number of BP to be connected
3
Casing colour
Ivory white
Type
Hermetically sealed scroll type
Compressor
Motor output
kW
2.5
3.0
3.5
Cooling
/s
(cfm)
—
—
—
Airflow rate (H)
Heating
2.5
1,767 (3,742)
Type
1,767 (3,742)
R-410A
Refrigerant
Charge
kg
4.0
Model
DAPHNE FVC68D
Refrigerant oil
Charge
1.5
Cooling
Sound level
52
52
53
54
Heating
—
—
—
54
55
56
Cooling
67
68
69
67
68
69
—
—
—
69
70
71
dB (A)
Heating
Dimensions (H x W x D)
mm
Machine weight
1,345 x 900 x 320
kg
125
Cooling
ÝCDB
- 5 to 46
Heating
ÝCWB
Operating range
Piping connections
-15 to 15.5
—
Number of wiring connections
piping length
54
dB (A)
Sound power
level
Max. interunit
53
3 for power supply (including earth wiring), 2 for interunit wiring (outdoor unit-BP)
Liquid (flare)
mm
ø9.5
Gas (brazing)
mm
ø19.1
ø18.0
Drain
mm
Total main piping and
branch piping
m
Total main piping
m
Total branch piping
m
Max. length for each room
m
15
kg/m
Necessary*
m
Between indoor or BP unit and outdoor unit: 30
m
Between indoor and BP unit: 15
Necessity of additional charge
Max. height difference
115
135
145
115
135
145
60
80
90
55
60
80
90
Note: * Refrigerant charge is required. (Chargeless piping length 0 m)
Formula for calculation charge: R (kg)
R = Total length (m) of liquid pipe size at ø9.5 x 0.054 + Total length (m) of liquid piping size at ø6.4 x 0.022
Measurement conditions
1. Cooling operation data is based on the following conditions: indoor temp. 27ÝCDB, 19ÝCWB; outdoor temp. 35ÝCDB.
2. Heating operation data is based on the following conditions: indoor temp. 20ÝCDB; outdoor temp. 7ÝCDB, 6ÝCWB.
3. Sound levels are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
29
Indoor unit
Ceiling-mounted cassette (multi flow) type
Cooling only
Model name
FCQ50BVE
FCQ35BVE
Heat pump
FCQ60BVE
FCQ71BVE
Cooling
Airflow rate (H)
Heating
/s
(cfm)
FCQ50BVE
FCQ60BVE
FCQ71BVE
233 (494)
250 (530)
317 (671)
233 (494)
250 (530)
317 (671)
—
—
—
233 (494)
250 (530)
317 (671)
Cooling
Sound level*
(H/L)
Heating
33/29
35/30
33/29
35/30
—
—
33/29
35/30
48
50
48
50
—
—
48
50
dB (A)
Cooling
Sound power
level (H)
Heating
dB (A)
2 steps
Fan speed
Microcomputer control
Temperature control
Unit dimensions (H x W x D)
Machine weight
Piping connections
230 x 840 x 840
mm
24
kg
Liquid (flare)
mm
Gas (flare)
mm
Drain
mm
ø6.4
ø9.5
ø9.5
ø12.7
ø6.4
ø15.9
ø9.5
ø9.5
ø15.9
ø12.7
I.D ø25 x O.D ø32
Both liquid and gas pipes
Heat insulation
Panel
(option)
FCQ35BVE
1 phase, 220-240 V/220 V, 50/60 Hz
Power supply
Model
BYC125K-W1
Colour
White
Dimensions (H x W x D)
mm
40 x 950 x 950
Weight
kg
5
Note: * For 220 V operation.
Ceiling-mounted cassette (compact multi flow) type
600 x 600
Cooling only
Model name
FFQ25BV1B
FFQ35BV1B
Heat pump
FFQ50BV1B
FFQ60BV1B
FFQ35BV1B
FFQ50BV1B
FFQ60BV1B
1 phase, 220-240 V, 50 Hz
Power supply
Cooling
Airflow rate (H)
Heating
/s
(cfm)
Cooling
Sound level*
(H/L)
Heating
Sound power
level (H)
Heating
150 (318)
167 (353)
200 (424)
250 (530)
150 (318)
167 (353)
200 (424)
250 (530)
—
—
—
—
150 (318)
167 (353)
200 (424)
250 (530)
29.5/24.5
32/25
36/27
41/32
29.5/24.5
32/25
36/27
41/32
—
—
—
—
29.5/24.5
32/25
36/27
41/32
46.5
49
53
58
46.5
49
53
58
—
—
—
—
46.5
49
53
58
dB (A)
Cooling
dB (A)
2 steps
Fan speed
Microcomputer control
Temperature control
Unit dimensions (H x W x D)
Piping connections
286 x 575 x 575
mm
kg
17.5
Liquid (flare)
mm
ø6.4
Gas (flare)
mm
Drain
mm
Machine weight
ø9.5
ø9.5
ø12.7
ø12.7
VP20 (External Dia. 26/Internal Dia. 20)
Both liquid and gas pipes
Heat insulation
BYFQ60B8W1
Model
Panel
(option)
FFQ25BV1B
Colour
White
Dimensions (H x W x D)
mm
55 x 700 x 700
Weight
kg
2.7
Note: * Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
30
Ceiling-mounted built-in type
Cooling only
Model name
Heat pump
FBQ71BV1
FBQ60BV1
Power supply
FBQ60BV1
Cooling
Airflow rate (H)
Heating
/s
(cfm)
283 (600)
317 (670)
—
—
Cooling
Sound level*
(H/L)
Heating
Sound power
level (H)
Heating
283 (600)
317 (670)
283 (600)
317 (670)
41/35
dB (A)
—
41/35
Cooling
60
dB (A)
—
60
Fan speed
2 steps
Temperature control
Microcomputer control
Dimensions (H x W x D)
Machine weight
Piping connections
300 x 1,000 x 800
mm
41
kg
Liquid (flare)
mm
ø6.4
ø9.5
Gas (flare)
mm
ø12.7
ø15.9
Drain
mm
ø6.4
ø9.5
ø12.7
ø15.9
I.D ø25 x O.D ø32
Heat insulation
Both liquid and gas pipes
Model
Panel
(option)
FBQ71BV1
1 phase, 220-240 V, 50 Hz
BYBS71DJW1
Colour
White
Dimensions (H x W x D)
mm
55 x 1,100 x 500
Weight
kg
4.5
Note: * For 220 V operation.
Ceiling-suspended type
Cooling only
FHQ35BVV1B
Model name
Heat pump
FHQ50BVV1B
Power supply
Airflow rate (H)
Heating
/s
(cfm)
Cooling
Sound level
(H/L)
217 (458)
283 (600)
217 (458)
283 (600)
217 (458)
267 (564)
—
—
—
37/32
38/33
39/33
37/32
38/33
39/33
Heating
—
—
—
37/32
38/33
39/33
Cooling
53/48
54/49
55/49
53/48
54/49
55/49
—
—
—
53/48
54/49
55/49
dB (A)
Sound power
level (H/L)
dB (A)
Heating
Fan speed
2 steps
Temperature control
Microcomputer control
Dimensions (H x W x D)
Machine weight
31
FHQ60BVV1B
White
Cooling
Heat insulation
FHQ50BVV1B
1 phase, 220-240 V, 50 Hz
Front panel colour
Piping connections
FHQ35BVV1B
FHQ60BVV1B
195 x 960 x 680
mm
kg
Liquid (flare)
mm
Gas (flare)
mm
Drain
mm
24
195 x 960 x 680
195 x 1,160 x 680
25
24
27
195 x 1,160 x 680
25
27
ø6.4
ø9.5
ø12.7
ø9.5
VP 20 (External Dia. 26/Internal Dia. 20)
Both liquid and gas pipes
ø12.7
<
Duct-connected type 700 mm width
>
Cooling only
Model name
CDKS25EAVMA
Heat pump
CDKS35EAVMA
Power supply
CDXS35EAVMA
1 phase, 220-240 V/220-230 V, 50/60 Hz
Cooling
Airflow rate (H)
Heating
145 (307)
/s
(cfm)
—
145 (307)
35/31/29
Cooling
Sound level*
(H/L/SL)
dB (A)
Heating
—
35/31/29
53
Cooling
Sound power
level (H)
dB (A)
Heating
—
53
Fan speed
5 steps, quiet and automatic
Temperature control
Microcomputer control
Dimensions (H x W x D)
Machine weight
Piping connections
CDXS25EAVMA
200 x 700 x 620
mm
kg
21
Liquid (flare)
mm
ø6.4
Gas (flare)
mm
ø9.5
Drain
mm
VP 20 (External Dia. 26/Internal Dia. 20)
Heat insulation
Both liquid and gas pipes
External static pressure
30
Pa
Note: * The operation sound level values represent those for rear-suction operation and an external static pressure of 30 Pa. Sound level values for bottom-suction operation can
be obtained by adding 6 dB.
<
Duct-connected type 900/1,100 mm width
>
Cooling only
Model name
Heat pump
CDKS25CVMA CDKS35CVMA CDKS50CVMA CDKS60CVMA FDXS25CVMA
Power supply
Cooling
Airflow rate (H)
Heating
/s
(cfm)
Cooling
Sound level*
(H/L/SL)
Heating
Sound power
level (H)
Heating
FDXS50CVMA
FDXS60CVMA
158 (335)
167 (353)
200 (424)
267 (565)
158 (335)
167 (353)
200 (424)
267 (565)
—
—
—
—
158 (335)
167 (353)
200 (424)
267 (565)
35/31/29
37/33/31
38/34/32
35/31/29
37/33/31
38/34/32
—
—
—
35/31/29
37/33/31
38/34/32
53
55
56
53
55
56
—
—
—
53
55
56
dB (A)
Cooling
dB (A)
Fan speed
5 steps, quiet and automatic
Temperature control
Microcomputer control
Dimensions (H x W x D)
Machine weight
Piping connections
FDXS35CVMA
1 phase, 220-240 V/220-230 V, 50/60 Hz
mm
kg
Liquid (flare)
mm
Gas (flare)
mm
Drain
mm
Heat insulation
External static pressure
200 x 900 x 620
25
200 x 1,100 x 620
27
30
200 x 900 x 620
25
200 x 1,100 x 620
27
30
ø6.4
ø9.5
ø9.5
ø12.7
ø12.7
VP 20 (External Dia. 26/Internal Dia. 20)
Both liquid and gas pipes
Pa
40
Note: * The operation sound level values represent those for rear-suction operation and an external static pressure of 40 Pa. Sound level values for bottom-suction operation can
be obtained by adding 5 dB.
32
Wall-mounted type
Cooling only
Model name
FTKS20DVMA
FTKS25GVMA
Power supply
Heat pump
FTKS35GVMA
FTXS25GVMA
FTXS35GVMA
1 phase, 220-240 V/220-230 V, 50/60 Hz
White
Front panel colour
Cooling
Airflow rate (H)
Heating
145 (307)
/s
(cfm)
Cooling
Sound level
(H/L/SL)
Heating
Sound power
level (H)
Heating
148 (314)
145 (307)
148 (314)
—
—
157 (332)
162 (342)
37/25/22
38/26/23
37/25/22
38/26/23
—
—
37/28/25
38/29/26
53
54
53
54
—
—
53
54
dB (A)
Cooling
dB (A)
5 steps, quiet and automatic
Fan speed
Microcomputer control
Temperature control
Dimensions (H x W x D)
283 x 800 x 195
mm
kg
9
Liquid (flare)
mm
ø6.4
Gas (flare)
mm
ø9.5
Drain
mm
ø18.0
Machine weight
Piping connections
FTXS20DVMA
Both liquid and gas pipes
Heat insulation
Wall-mounted type
Cooling only
FTKS50JVMA
Model name
FTKS60JVMA
Power supply
Heat pump
Cooling
Airflow rate (H)
Heating
/s
(cfm)
Cooling
Sound level
(H/L/SL)
245 (519)
270 (572)
290 (614)
245 (519)
270 (572)
290 (614)
—
—
—
270 (572)
290 (614)
358 (759)
44/35/32
45/36/33
46/37/34
44/35/32
45/36/33
46/37/34
Heating
—
—
—
42/33/30
44/35/32
46/37/34
Cooling
60
61
62
60
61
62
—
—
—
58
60
62
dB (A)
Heating
5 steps, quiet and automatic
Fan speed
Microcomputer control
Temperature control
Dimensions (H x W x D)
Machine weight
33
FTXS71JVMA
dB (A)
Sound power
level (H)
Heat insulation
FTXS60JVMA
White
Front panel colour
Piping connections
FTXS50JVMA
FTKS71JVMA
1 phase, 220-240 V/220-230 V, 50/60 Hz
mm
290 x 1,050 x 250
kg
12
Liquid (flare)
mm
Gas (flare)
mm
Drain
mm
ø6.4
ø12.7
ø15.9
ø12.7
ø18.0
Both liquid and gas pipes
ø15.9
Floor-standing type
Heat pump
Model name
1 phase, 220-240 V, 50 Hz
Power supply
White
Front panel colour
Cooling
Airflow rate (H)
Heating
/s
(cfm)
Cooling
Sound level
(H/L/SL)
137 (290)
142 (300)
178 (378)
147 (311)
157 (332)
197 (417)
38/26/23
39/27/24
44/36/32
Heating
38/26/23
39/27/24
45/36/32
Cooling
54
55
56
55
57
dB (A)
Sound power
level (H)
dB (A)
Heating
54
Fan speed
5 steps, quiet and automatic
Temperature control
Microcomputer control
Unit dimensions (H x W x D)
Machine weight
Piping connections
FVXS50GV1A
FVXS35GV1A
FVXS25GV1A
mm
600 x 700 x 210
kg
14
Liquid (flare)
mm
ø6.4
Gas (flare)
mm
Drain
mm
ø9.5
ø12.7
ø20.0
Heat insulation
Both liquid and gas pipes
Floor/Ceiling-suspended dual type
Heat pump
Model name
FLXS25BVMA
FLXS35GVMA
Power supply
1 phase, 220-240 V/220-230 V, 50/60 Hz
Front panel colour
Almond white
Cooling
126 (268)
143 (304)
190 (402)
200 (424)
153 (325)
163 (346)
202 (427)
213 (452)
37/31/28
38/32/29
47/39/36
48/41/39
Heating
37/31/29
39/33/30
46/35/33
47/37/34
Cooling
53
54
63
64
53
55
62
63
Airflow rate (H)
Heating
/s
(cfm)
Cooling
Sound level
(H/L/SL)
dB (A)
Sound power
level (H)
dB (A)
Heating
Fan speed
5 steps, quiet and automatic
Temperature control
Microcomputer control
Dimensions (H x W x D)
Machine weight
Piping connections
Heat insulation
FLXS60GVMA
FLXS50GVMA
mm
kg
Liquid (flare)
mm
Gas (flare)
mm
Drain
mm
490 x 1,050 x 200
16
17
ø6.4
ø9.5
ø12.7
ø18.0
Both liquid and gas pipes
34
BP unit
3 ports
Model name
2 ports
3 ports (connectable to 1-3 indoor units)
2 ports (connectable to 1-2 indoor units)
BPMKS967A3
BPMKS967A2
1 phase, 220-240 V/220-230 V, 50/60 Hz
Power supply
Power consumption
W
10
Running current
A
0.05
Dimensions (H x W x D)
kg
(Brazing)
Liquid
Main
Gas
ø6.4 x 3
ø15.9 x 3
Heat insulation
ø15.9 x 2
Both liquid and gas pipes
Connectable indoor units
2.0 kW class to 7.1 kW class
Min. rated capacity of
connectable indoor units
kW
Max. rated capacity of
connectable indoor units
kW
35
ø6.4 x 2
ø19.1 x 1
mm
Branch mm
Note: * Total auxiliary piping length.
7.5
ø9.5 x 1
mm
Branch mm
Main
8
3 for power supply (including earth wiring), 2 for interunit wiring (outdoor unit-BP, BP-BP), 4 for interunit wiring (BP-indoor unit)
Number of wiring connections
Piping
connections
180 x 294 (+356*) x 350
mm
Machine weight
2.0
20.8
14.2
Options
Outdoor unit
No.
RMKS112EV1A RMKS140EV1A RMKS160EV1A RMXS112EV1A RMXS140EV1A RMXS160EV1A
Item
1
Central drain plug
KKPJ5F180
2
Air direction adjustment grille
KPW945A4
Indoor unit
Ceiling-mounted cassette (multi flow) type
No.
Decoration panel
2
Panel spacer
4
5
FCQ50BVE
FCQ60BVE
KDBP55H160WA
Fresh air intake kit
Without T-shaped pipe and fan*1
KDDP55D160
With T-shaped pipe, without fan*2
KDDP55D160K
Direct installation type*3
KDDJ55X160
(Colourimetric method 65%)
KAFP556D80
(Colourimetric method 90%)
KAFP557D80
(Colourimetric method 65%)
KAFP552H80
(Colourimetric method 90%)
KAFP553H80
High-efficiency filter
Replacement high-efficiency filter
6
High-efficiency filter chamber
KDDF55DA160
7
Longlife filter
KAF551KA160
8
Branch duct chamber
KDJ55K80
Wired type
9
FCQ71BVE
BYC125K-W1
Chamber type
3
FCQ35BVE
Item
1
Remote controller
BRC1C61
Heat pump use
BRC7C612W
Cooling only use
BRC7C613W
Wireless type
10
Group control adaptor*4
KRP4A53
11
Wiring adaptor for electrical appendices*4
KRP1B57
12
Installation box for adaptor PCB
KRP1B98
Notes:
*1. With a suction chamber. Fresh air intake is from 2 holes on the sides of the connection chamber. (This method should be selected if a wireless remote controller is used.)
*2. Without a suction chamber. Fresh air intake is from 2 holes on the connection chamber via a T-shaped pipe connection. (A wireless remote controller cannot be used in this case.)
*3. Without a suction chamber. Fresh air intake is directly from a hole on the main unit.
*4. Installation box for adaptor PCB (KRP1B98) is necessary.
Ceiling-mounted cassette (compact multi flow) type
No.
1
Item
FFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1B
Decoration panel
BYFQ60B8W1
Wired type*1
2
Remote controller
Wireless type
BRC1C61
Heat pump use
BRC7E530W
Cooling only use
BRC7E531W
2
3
Adaptor for wiring*
4
Wiring adaptor for electrical appendices*2
KRP4AA53
5
Installation box for adaptor PCB
KRP1BA101
6
Remote sensor (for indoor temperature)
KRCS01-1B
7
Replacement long-life filter
8
Fresh air intake kit
9
Sealing member for air discharge outlet
KDBHQ44B60
10
Panel spacer
KDBQ44B60A
KRP1BA57
KAFQ441B60
Direct installation type
KDDQ44X60
Notes:
*1. Wiring for wired remote controller should be obtained locally.
*2. Installation box for adaptor PCB (KRP1BA101) is necessary.
36
Ceiling-mounted built-in type
No.
Item
1
Decoration panel
2
Service access panel
FBQ60BV1
FBQ71BV1
BYBS71DJW1
KTBJ25L80W
(Colourimetric method 65%)
3
High-efficiency filter
4
Replacement long-life filter
5
Filter chamber for bottom suction
6
Filter chamber for rear suction
7
Canvas duct
8
Discharge grille
KAFJ252L80
(Colourimetric method 90%)
KAFJ253L80
Resin net
KAFJ251K80
KAJ25L80D
KAJ25L80B
KSA-25KA80
9
Discharge chamber
10
Branch duct
ø150
K-DG5DW
ø200
K-DG9DW
ø150
K-DGC5D
ø200
K-DGC9D
ø150
ø200
K-DDV20A
ø150
K-FDS151C(1m)/K-FDS152C(2m)/K-FDS153C(3m)/K-FDS154C(4m)/K-FDS155C(5m)/K-FDS156C(6m)
ø200
K-FDS201C(1m)/K-FDS202C(2m)/K-FDS203C(3m)/K-FDS204C(4m)/K-FDS205C(5m)/K-FDS206C(6m)
11
Flexible duct
12
Blind board
13
Adaptor for discharge
14
Flange for suction
15
Remote controller
16
Adaptor for wiring (Interlock for fresh air intake fan)
KRP1B54
17
Group control adaptor
KRP4A51
KBBJ25K80
KDAJ25K71
KDJ2507K80
Wired type
BRC1C61
Ceiling-suspended type
No.
FHQ35BVV1B FHQ50BVV1B FHQ60BVV1B
KAF501DA56
KAFJ501DA80
Item
1
Replacement long-life filter
2
Drain up kit
3
L-type piping kit (For upward direction)
4
Remote controller
5
Adaptor for wiring
6
Wiring adaptor for electrical appendices*
KRP4AA52
7
Installation box for adaptor PCB
KRP1CA93
KHFP5MA35
Wired type
Wireless type
FDU50M60VE
KHFP5MA63
BRC1C61
Heat pump use
BRC7EA63W
Cooling only use
BRC7EA66
KRP1BA54
Note: * Installation box for adaptor PCB (KRP1CA93) is necessary.
Duct-connected type
No.
Item
1
Wired remote controller*1
2
Wired remote controller cord
CDKS25EAVMA CDKS35EAVMA CDKS25CVMA
CDKS35CVMA
CDKS50CVMA
CDKS60CVMA
CDXS25EAVMA CDXS35EAVMA
FDXS35CVMA
FDXS50CVMA
FDXS60CVMA
FDXS25CVMA
BRC944B2
Length 3 m (shielded wire)
BRCW901A03
Length 8 m (shielded wire)
BRCW901A08
3
5-room centralised
controller*2
KRC72
4
Wiring adaptor for time clock/remote controller*3
(Normal open pulse contact/normal open contact)
KRP413A1S
5
Wireless remote controller loss prevention chain
KKF917A4
6
Suction grille
7
Insulation kit for high humidity
KDGF19A45
KDT25N32
Notes:
*1. 3 m (BRCW901A03) or 8 m (BRCW901A08) length wired remote controller cord is necessary.
*2. A wiring adaptor (KRP413A1S) is also required for each indoor unit.
*3. Time clock and other devices should be obtained locally.
37
KDT25N50
KDT25N63
Wall-mounted type
FTKS20DVMA FTKS25GVMA FTKS35GVMA FTKS50JVMA FTKS60JVMA FTKS71JVMA
No.
Item
FTXS20DVMA FTXS25GVMA FTXS35GVMA FTXS50JVMA FTXS60JVMA FTXS71JVMA
1
BRC944B2
Wired remote controller*1
Length 3 m (shielded wire)
BRCW901A03
Length 8 m (shielded wire)
BRCW901A08
2
Wired remote controller cord
3
5-room centralised controller*2
4
Wiring adaptor for time clock/remote controller*3
(Normal open pulse contact/normal open contact)
5
Titanium apatite photocatalytic air-purifying filter*4
6
Wireless remote controller loss prevention chain
KRC72
KRP413A1S
KAF970A46
KKF917A4
KKF910A4
Notes:
*1. 3 m (BRCW901A03) or 8 m (BRCW901A08) length wired remote controller cord is necessary.
*2. A wiring adaptor (KRP413A1S) is also required for each indoor unit.
*3. Time clock and other devices should be obtained locally.
*4. Filter is a standard accessory. It should be replaced approximately every 3 years.
Floor-standing type
No.
1
Item
5-room centralised controller*
FVXS25GV1A
FVXS35GV1A
1
FVXS50GV1A
KRC72
2
2
Wiring adaptor for time clock/remote controller*
(Normal open pulse contact/normal open contact)
KRP413A1S
3
Titanium apatite photocatalytic air-purifying filter*3
KAF968A42
4
Remote controller loss prevention chain
KKF910A4
Notes:
*1. A wiring adaptor (KRP413A1S) is also required for each indoor unit.
*2. Time clock and other devices should be obtained locally.
*3. Filter is a standard accessory. It should be replaced approximately every 3 years.
Floor/ceiling-suspended dual type
No.
Item
FLXS25BVMA FLXS35GVMA FLXS50GVMA FLXS60GVMA
1
1
5-room centralised controller*
2
Wiring adaptor for time clock/remote controller*2
(Normal open pulse contact/normal open contact)
KRP413A1S
3
Photocatalytic deodorising filter with frame*3
KAZ917B41
KRC72
3
KAZ917B42
4
Photocatalytic deodorising filter without frame*
5
Air-purifying filter with frame*4
KAF925B41
6
Air-purifying filter without frame*4
KAF925B42
7
Remote controller loss prevention chain
KKF917A4
Notes:
*1. A wiring adaptor (KRP413A1S) is also required for each indoor unit.
*2. Time clock and other devices should be obtained locally.
*3. The photocatalytic deodorising filter is a standard accessory. It can be reused indefinitely if it is exposed to direct sunlight once every 6 months. This accessory is only
required if the original filter is damaged or lost, etc.
*4. The air-purifying filter is a standard accessory. It should be replaced approximately once every 3 months. This accessory is required for the replacement of filters.
BP unit
No.
1
Item
BPMKS967A2
REFNET joint
BPMKS967A3
KHRP26A22T
Note:
A single BP unit does not require a REFNET joint. 2 BP units require only 1 REFNET joint, and 3 BP units require only 2 REFNET joints.
Control system
No.
Item
Model No.
1
Central remote controller*
DCS302CA61
2
Unified on/off controller*
DCS301BA61
3
Schedule timer*
DST301BA61
4
Interface adaptor
FTK(X)S-D/G/J, FVXS-F, FLXS-B, CDK(X)S-EA, C(F)DK(X)S-C
KRP928B2S
(For DIII-NET use)
FCQ-B, FFQ-B, FBQ-B, FHQ-B
DTA112B51
Note:
* An interface adaptor (KRP928B2S or DTA112B51) is also required for each indoor unit.
38
Selection Procedure
Outdoor unit RMK(X)S160E
Number of indoor units
Total indoor unit capacity
2 to 9 units
8.0
Indoor unit
model name
Rated capacity (kW)
to 20.8 kW
FTK(X)S-D/G/J, FVXS-G, FLXS-B/G, CDK(X)S-EA, C(F)DK(X)S-C, FCQ-B, FFQ-B, FBQ-B, FHQ-B
71
20
25
35
50
60
7.1
2.0
2.5
3.5
5.0
6.0
Capacity Tables
Cooling capacity
RMK(X)S112EV1A
Total indoor
unit capacity
(kW)
5.5
5.6
5.7
5.8
5.9
6.0
6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8
6.9
7.0
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
8.0
8.1
8.2
8.3
8.4
8.5
8.6
8.7
8.8
8.9
9.0
9.1
9.2
9.3
9.4
9.5
9.6
9.7
9.8
9.9
10.0
10.1
10.2
10.3
10.4
10.5
10.6
10.7
10.8
10.9
11.0
11.1
11.2
11.3
11.4
39
Cooling
capacity
(kW)
5.6
5.7
5.8
5.9
6.0
6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8
6.9
7.0
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
8.0
8.1
8.2
8.3
8.5
8.6
8.7
8.8
8.9
9.0
9.1
9.2
9.3
9.4
9.5
9.6
9.7
9.8
9.9
10.0
10.1
10.2
10.3
10.4
10.5
10.6
10.7
10.8
10.9
11.0
11.1
11.2
11.3
11.4
11.5
11.6
Power
consumption
(kW)
1.68
1.71
1.75
1.78
1.81
1.85
1.88
1.91
1.95
1.98
2.01
2.05
2.08
2.11
2.14
2.18
2.21
2.24
2.28
2.31
2.34
2.38
2.41
2.44
2.48
2.51
2.54
2.57
2.61
2.64
2.67
2.71
2.74
2.77
2.81
2.84
2.87
2.90
2.94
2.97
3.00
3.04
3.07
3.10
3.14
3.17
3.20
3.24
3.27
3.30
3.33
3.37
3.40
3.43
3.47
3.50
3.53
3.57
3.60
3.63
RMK(X)S140EV1A
Total indoor
unit capacity
(kW)
11.5
11.6
11.7
11.8
11.9
12.0
12.1
12.2
12.3
12.4
12.5
12.6
12.7
12.8
12.9
13.0
13.1
13.2
13.3
13.4
13.5
13.6
13.7
13.8
13.9
14.0
14.1
14.2
14.3
14.4
14.5
Cooling
capacity
(kW)
11.7
11.8
11.9
12.0
12.1
12.2
12.3
12.4
12.5
12.6
12.7
12.7
12.8
12.8
12.8
12.8
12.8
12.9
12.9
12.9
12.9
12.9
13.0
13.0
13.0
13.0
13.0
13.0
13.1
13.1
13.1
Power
consumption
(kW)
3.67
3.70
3.73
3.76
3.80
3.83
3.86
3.90
3.93
3.96
4.00
4.00
4.01
4.02
4.02
4.03
4.04
4.05
4.05
4.06
4.07
4.07
4.08
4.09
4.10
4.10
4.11
4.12
4.12
4.13
4.14
Total indoor
unit capacity
(kW)
7.0
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
8.0
8.1
8.2
8.3
8.4
8.5
8.6
8.7
8.8
8.9
9.0
9.1
9.2
9.3
9.4
9.5
9.6
9.7
9.8
9.9
10.0
10.1
10.2
10.3
10.4
10.5
10.6
10.7
10.8
10.9
11.0
11.1
11.2
11.3
11.4
11.5
11.6
11.7
11.8
11.9
12.0
12.1
12.2
12.3
12.4
12.5
12.6
12.7
12.8
12.9
Cooling
capacity
(kW)
6.9
7.0
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
8.0
8.1
8.2
8.3
8.4
8.5
8.6
8.7
8.8
8.9
9.0
9.1
9.2
9.3
9.4
9.5
9.6
9.7
9.8
9.9
10.0
10.1
10.2
10.3
10.4
10.5
10.5
10.6
10.7
10.8
10.9
11.0
11.1
11.2
11.3
11.4
11.5
11.6
11.7
11.8
11.9
12.0
12.1
12.2
12.3
12.4
12.5
12.6
12.7
Power
consumption
(kW)
1.80
1.84
1.87
1.91
1.95
1.98
2.02
2.06
2.10
2.13
2.17
2.21
2.25
2.28
2.32
2.36
2.40
2.43
2.47
2.51
2.54
2.58
2.62
2.66
2.69
2.73
2.77
2.81
2.84
2.88
2.92
2.96
2.99
3.03
3.07
3.10
3.14
3.18
3.22
3.25
3.29
3.33
3.37
3.40
3.44
3.48
3.52
3.55
3.59
3.63
3.67
3.70
3.74
3.78
3.81
3.85
3.89
3.93
3.96
4.00
Total indoor
unit capacity
(kW)
13.0
13.1
13.2
13.3
13.4
13.5
13.6
13.7
13.8
13.9
14.0
14.1
14.2
14.3
14.4
14.5
14.6
14.7
14.8
14.9
15.0
15.1
15.2
15.3
15.4
15.5
15.6
15.7
15.8
15.9
16.0
16.1
16.2
16.3
16.4
16.5
16.6
16.7
16.8
16.9
17.0
17.1
17.2
17.3
17.4
17.5
17.6
17.7
17.8
17.9
18.0
18.1
18.2
Cooling
capacity
(kW)
12.8
12.9
13.0
13.1
13.2
13.3
13.4
13.5
13.6
13.7
13.8
13.9
14.0
14.1
14.2
14.3
14.4
14.5
14.6
14.7
14.8
14.8
14.8
14.8
14.8
14.9
14.9
14.9
14.9
14.9
14.9
14.9
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.1
15.1
15.1
15.1
15.1
15.1
15.1
15.1
15.2
15.2
15.2
15.2
15.2
15.2
Power
consumption
(kW)
4.04
4.08
4.11
4.15
4.19
4.23
4.26
4.30
4.34
4.37
4.41
4.45
4.49
4.52
4.56
4.60
4.64
4.67
4.71
4.75
4.79
4.79
4.80
4.80
4.81
4.82
4.82
4.83
4.84
4.84
4.85
4.86
4.86
4.87
4.88
4.88
4.89
4.90
4.90
4.91
4.91
4.92
4.93
4.93
4.94
4.95
4.95
4.96
4.97
4.97
4.98
4.99
4.99
Number of REFNET joints
Number of BP units
1
Unnecessary
Number of
2 KHRP26A22T x 1
BP units
1 to 3 units
3 KHRP26A22T x 2
Cooling capacity
RMK(X)S160EV1A
Total indoor
unit capacity
(kW)
8.0
8.1
8.2
8.3
8.4
8.5
8.6
8.7
8.8
8.9
9.0
9.1
9.2
9.3
9.4
9.5
9.6
9.7
9.8
9.9
10.0
10.1
10.2
10.3
10.4
10.5
10.6
10.7
10.8
10.9
11.0
11.1
11.2
11.3
11.4
11.5
11.6
11.7
11.8
11.9
12.0
12.1
12.2
12.3
12.4
12.5
12.6
12.7
12.8
12.9
13.0
13.1
13.2
13.3
13.4
Cooling
capacity
(kW)
7.8
7.8
7.9
8.0
8.1
8.2
8.3
8.4
8.5
8.6
8.7
8.8
8.9
9.0
9.1
9.2
9.3
9.4
9.5
9.6
9.7
9.8
9.9
10.0
10.1
10.2
10.3
10.4
10.5
10.6
10.7
10.8
10.9
10.9
11.0
11.1
11.2
11.3
11.4
11.5
11.6
11.7
11.8
11.9
12.0
12.1
12.2
12.3
12.4
12.5
12.6
12.7
12.8
12.9
13.0
Power
consumption
(kW)
2.04
2.09
2.13
2.17
2.21
2.26
2.30
2.34
2.39
2.43
2.47
2.51
2.56
2.60
2.64
2.68
2.73
2.77
2.81
2.85
2.90
2.94
2.98
3.03
3.07
3.11
3.15
3.20
3.24
3.28
3.32
3.37
3.41
3.45
3.50
3.54
3.58
3.62
3.67
3.71
3.75
3.79
3.84
3.88
3.92
3.96
4.01
4.05
4.09
4.14
4.18
4.22
4.26
4.31
4.35
Total indoor
unit capacity
(kW)
13.5
13.6
13.7
13.8
13.9
14.0
14.1
14.2
14.3
14.4
14.5
14.6
14.7
14.8
14.9
15.0
15.1
15.2
15.3
15.4
15.5
15.6
15.7
15.8
15.9
16.0
16.1
16.2
16.3
16.4
16.5
16.6
16.7
16.8
16.9
17.0
17.1
17.2
17.3
17.4
17.5
17.6
17.7
17.8
17.9
18.0
18.1
18.2
18.3
18.4
18.5
18.6
18.7
18.8
18.9
Cooling
capacity
(kW)
13.1
13.2
13.3
13.4
13.5
13.6
13.7
13.8
13.9
14.0
14.0
14.1
14.2
14.3
14.4
14.5
14.6
14.7
14.8
14.9
15.0
15.1
15.2
15.3
15.4
15.5
15.5
15.5
15.6
15.6
15.6
15.6
15.6
15.6
15.7
15.7
15.7
15.7
15.7
15.8
15.8
15.8
15.8
15.8
15.8
15.9
15.9
15.9
15.9
15.9
16.0
16.0
16.0
16.0
16.0
Power
consumption
(kW)
4.39
4.43
4.48
4.52
4.56
4.60
4.65
4.69
4.73
4.78
4.82
4.86
4.90
4.95
4.99
5.03
5.07
5.12
5.16
5.20
5.25
5.29
5.33
5.37
5.42
5.46
5.46
5.46
5.46
5.46
5.46
5.46
5.46
5.46
5.46
5.46
5.46
5.46
5.46
5.47
5.47
5.47
5.47
5.47
5.47
5.47
5.47
5.47
5.47
5.47
5.47
5.47
5.47
5.47
5.47
Total indoor
unit capacity
(kW)
19.0
19.1
19.2
19.3
19.4
19.5
19.6
19.7
19.8
19.9
20.0
20.1
20.2
20.3
20.4
20.5
20.6
20.7
20.8
Cooling
capacity
(kW)
16.0
16.1
16.1
16.1
16.1
16.1
16.2
16.2
16.2
16.2
16.2
16.2
16.3
16.3
16.3
16.3
16.3
16.4
16.4
Power
consumption
(kW)
5.47
5.47
5.48
5.48
5.48
5.48
5.48
5.48
5.48
5.48
5.48
5.48
5.48
5.48
5.48
5.48
5.48
5.48
5.48
Note:
Cooling operation data is based on the following conditions: indoor temp. 27ÝCDB, 19ÝCWB; outdoor temp. 35ÝCDB.
The rated capacities above show the rise in the total indoor unit capacity when operating frequency is constant. Values for changes in capacity are fixed
after accounting for variations in operating frequency and should be used as reference values.
40
Capacity Tables
Heating capacity
RMXS112EV1A
Total indoor
unit capacity
(kW)
5.5
5.6
5.7
5.8
5.9
6.0
6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8
6.9
7.0
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
8.0
8.1
8.2
8.3
8.4
8.5
8.6
8.7
8.8
8.9
9.0
9.1
9.2
9.3
9.4
9.5
9.6
9.7
9.8
9.9
10.0
10.1
10.2
10.3
10.4
10.5
10.6
10.7
10.8
10.9
11.0
11.1
11.2
11.3
11.4
41
Heating
capacity
(kW)
6.8
6.9
7.0
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
8.0
8.1
8.2
8.3
8.4
8.5
8.6
8.7
8.8
9.0
9.1
9.2
9.3
9.4
9.5
9.6
9.7
9.8
9.9
10.0
10.1
10.2
10.3
10.4
10.5
10.6
10.7
10.8
10.9
11.0
11.1
11.2
11.4
11.5
11.6
11.7
11.8
11.9
12.0
12.1
12.2
12.3
12.4
12.5
12.6
12.7
12.8
12.9
Power
consumption
(kW)
2.24
2.26
2.29
2.32
2.35
2.37
2.40
2.43
2.45
2.48
2.51
2.53
2.56
2.59
2.61
2.64
2.67
2.69
2.72
2.75
2.78
2.80
2.83
2.86
2.88
2.91
2.94
2.96
2.99
3.02
3.04
3.07
3.10
3.12
3.15
3.18
3.21
3.23
3.26
3.29
3.31
3.34
3.37
3.39
3.42
3.45
3.47
3.50
3.53
3.55
3.58
3.61
3.63
3.66
3.69
3.72
3.74
3.77
3.80
3.82
RMXS140EV1A
Total indoor
unit capacity
(kW)
11.5
11.6
11.7
11.8
11.9
12.0
12.1
12.2
12.3
12.4
12.5
12.6
12.7
12.8
12.9
13.0
13.1
13.2
13.3
13.4
13.5
13.6
13.7
13.8
13.9
14.0
14.1
14.2
14.3
14.4
14.5
Heating
capacity
(kW)
13.0
13.1
13.2
13.3
13.4
13.5
13.5
13.5
13.5
13.5
13.5
13.6
13.6
13.6
13.6
13.6
13.7
13.7
13.7
13.7
13.7
13.7
13.8
13.8
13.8
13.8
13.8
13.8
13.8
13.9
13.9
Power
consumption
(kW)
3.85
3.88
3.90
3.93
3.98
3.97
3.97
3.97
3.97
3.96
3.96
3.96
3.95
3.95
3.95
3.95
3.94
3.94
3.94
3.93
3.93
3.93
3.92
3.92
3.92
3.91
3.91
3.91
3.90
3.90
3.90
Total indoor
unit capacity
(kW)
7.0
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
8.0
8.1
8.2
8.3
8.4
8.5
8.6
8.7
8.8
8.9
9.0
9.1
9.2
9.3
9.4
9.5
9.6
9.7
9.8
9.9
10.0
10.1
10.2
10.3
10.4
10.5
10.6
10.7
10.8
10.9
11.0
11.1
11.2
11.3
11.4
11.5
11.6
11.7
11.8
11.9
12.0
12.1
12.2
12.3
12.4
12.5
12.6
12.7
12.8
12.9
Heating
capacity
(kW)
8.4
8.5
8.6
8.7
8.8
8.9
9.0
9.1
9.2
9.4
9.5
9.6
9.7
9.8
9.9
10.0
10.1
10.2
10.3
10.4
10.5
10.6
10.7
10.8
10.9
11.0
11.1
11.3
11.4
11.5
11.6
11.7
11.8
11.9
12.0
12.1
12.2
12.3
12.4
12.5
12.6
12.7
12.8
12.9
13.0
13.2
13.3
13.4
13.5
13.6
13.7
13.8
13.9
14.0
14.1
14.2
14.3
14.4
14.5
14.6
Power
consumption
(kW)
2.70
2.73
2.76
2.80
2.83
2.87
2.90
2.94
2.97
3.01
3.04
3.08
3.11
3.15
3.18
3.21
3.25
3.28
3.32
3.35
3.39
3.42
3.46
3.49
3.53
3.56
3.60
3.63
3.66
3.70
3.73
3.77
3.80
3.84
3.87
3.91
3.94
3.98
4.01
4.05
4.08
4.11
4.15
4.18
4.22
4.25
4.29
4.32
4.36
4.39
4.43
4.46
4.50
4.53
4.56
4.60
4.63
4.67
4.70
4.74
Total indoor
unit capacity
(kW)
13.0
13.1
13.2
13.3
13.4
13.5
13.6
13.7
13.8
13.9
14.0
14.1
14.2
14.3
14.4
14.5
14.6
14.7
14.8
14.9
15.0
15.1
15.2
15.3
15.4
15.5
15.6
15.7
15.8
15.9
16.0
16.1
16.2
16.3
16.4
16.5
16.6
16.7
16.8
16.9
17.0
17.1
17.2
17.3
17.4
17.5
17.6
17.7
17.8
17.9
18.0
18.1
18.2
Heating
capacity
(kW)
14.7
14.8
14.9
15.1
15.2
15.3
15.4
15.5
15.6
15.7
15.8
15.9
16.0
16.0
16.0
16.1
16.1
16.1
16.1
16.1
16.2
16.2
16.2
16.2
16.2
16.3
16.3
16.3
16.3
16.3
16.3
16.4
16.4
16.4
16.4
16.4
16.5
16.5
16.5
16.5
16.5
16.6
16.6
16.6
16.6
16.6
16.7
16.7
16.7
16.7
16.7
16.8
16.8
Power
consumption
(kW)
4.77
4.81
4.84
4.88
4.91
4.95
4.98
5.01
5.05
5.08
5.12
5.15
5.19
5.17
5.15
5.14
5.12
5.10
5.09
5.07
5.05
5.04
5.02
5.01
4.99
4.97
4.96
4.94
4.92
4.91
4.89
4.87
4.86
4.84
4.82
4.81
4.79
4.77
4.76
4.74
4.72
4.71
4.69
4.67
4.66
4.64
4.62
4.61
4.59
4.57
4.56
4.54
4.52
Heating capacity
RMXS160EV1A
Total indoor
unit capacity
(kW)
8.0
8.1
8.2
8.3
8.4
8.5
8.6
8.7
8.8
8.9
9.0
9.1
9.2
9.3
9.4
9.5
9.6
9.7
9.8
9.9
10.0
10.1
10.2
10.3
10.4
10.5
10.6
10.7
10.8
10.9
11.0
11.1
11.2
11.3
11.4
11.5
11.6
11.7
11.8
11.9
12.0
12.1
12.2
12.3
12.4
12.5
12.6
12.7
12.8
12.9
13.0
13.1
13.2
13.3
13.4
Heating
capacity
(kW)
9.3
9.4
9.5
9.6
9.7
9.8
9.9
10.0
10.1
10.2
10.3
10.4
10.5
10.6
10.7
10.8
10.9
11.0
11.1
11.2
11.3
11.4
11.5
11.6
11.8
11.9
12.0
12.1
12.2
12.3
12.4
12.5
12.6
12.7
12.8
12.9
13.0
13.1
13.2
13.3
13.4
13.5
13.6
13.7
13.8
13.9
14.0
14.1
14.2
14.3
14.4
14.5
14.6
14.7
14.8
Power
consumption
(kW)
2.62
2.65
2.68
2.71
2.74
2.78
2.81
2.84
2.87
2.90
2.93
2.96
2.99
3.02
3.05
3.08
3.11
3.14
3.17
3.20
3.23
3.26
3.29
3.32
3.35
3.38
3.41
3.44
3.47
3.50
3.54
3.57
3.60
3.63
3.66
3.69
3.72
3.75
3.78
3.81
3.84
3.87
3.90
3.93
3.96
3.99
4.02
4.05
4.08
4.11
4.14
4.17
4.20
4.23
4.26
Total indoor
unit capacity
(kW)
13.5
13.6
13.7
13.8
13.9
14.0
14.1
14.2
14.3
14.4
14.5
14.6
14.7
14.8
14.9
15.0
15.1
15.2
15.3
15.4
15.5
15.6
15.7
15.8
15.9
16.0
16.1
16.2
16.3
16.4
16.5
16.6
16.7
16.8
16.9
17.0
17.1
17.2
17.3
17.4
17.5
17.6
17.7
17.8
17.9
18.0
18.1
18.2
18.3
18.4
18.5
18.6
18.7
18.8
18.9
Heating
capacity
(kW)
14.9
15.0
15.1
15.2
15.3
15.4
15.5
15.7
15.8
15.9
16.0
16.1
16.2
16.3
16.4
16.5
16.6
16.7
16.8
16.9
17.0
17.1
17.2
17.3
17.4
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.6
17.6
17.6
17.6
17.6
17.6
17.6
17.6
17.6
17.6
17.6
17.6
17.6
17.6
17.6
17.6
17.6
Power
consumption
(kW)
4.30
4.33
4.36
4.39
4.42
4.45
4.48
4.51
4.54
4.57
4.60
4.63
4.66
4.69
4.72
4.75
4.78
4.81
4.84
4.87
4.90
4.93
4.96
4.99
5.02
5.06
5.05
5.04
5.03
5.03
5.02
5.01
5.01
5.00
4.99
4.99
4.98
4.97
4.96
4.96
4.95
4.94
4.94
4.93
4.92
4.92
4.91
4.90
4.89
4.89
4.88
4.87
4.87
4.86
4.85
Total indoor
unit capacity
(kW)
19.0
19.1
19.2
19.3
19.4
19.5
19.6
19.7
19.8
19.9
20.0
20.1
20.2
20.3
20.4
20.5
20.6
20.7
20.8
Heating
capacity
(kW)
17.6
17.6
17.6
17.6
17.6
17.6
17.6
17.6
17.6
17.7
17.7
17.7
17.7
17.7
17.7
17.7
17.7
17.7
17.7
Power
consumption
(kW)
4.85
4.84
4.83
4.82
4.82
4.81
4.80
4.80
4.79
4.78
4.78
4.77
4.76
4.75
4.75
4.74
4.73
4.73
4.72
Note:
Heating operation data is based on the following conditions: indoor temp. 20ÝCDB; outdoor temp. 7ÝCDB, 6ÝCWB.
The rated capacities above show the rise in the total indoor unit capacity when operating frequency is constant. Values for changes in capacity are fixed
after accounting for variations in operating frequency and should be used as reference values.
42
Warning
Daikin Industries, Ltd.’s products are manufactured for export to numerous countries throughout the
world. Daikin Industries, Ltd. does not have control over which products are exported to and used in a
particular country. Prior to purchase, please therefore confirm with your local authorised importer,
distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for
use, in the region where the product will be used. This statement does not purport to exclude, restrict
or modify the application of any local legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Cautions on product corrosion
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
Organization:
DAIKIN INDUSTRIES, LTD.
AIR CONDITIONING MANUFACTURING
DIVISION
JMI-0107
Scope of Registration:
THE DESIGN/DEVELOPMENT AND
MANUFACTURE OF COMMERCIAL AIR
CONDITIONING, HEATING, COOLING,
REFRIGERATING EQUIPMENT,
COMMERCIAL HEATING EQUIPMENT,
RESIDENTIAL AIR CONDITIONING
EQUIPMENT, HEAT RECLAIM VENTILATION,
AIR CLEANING EQUIPMENT, MARINE TYPE
CONTAINER REFRIGERATION UNITS,
COMPRESSORS AND VALVES.
Organization:
DAIKIN INDUSTRIES
(THAILAND) LTD.
JQA-1452
Scope of Registration:
THE DESIGN/DEVELOPMENT
AND MANUFACTURE OF AIR
CONDITIONERS AND THE
COMPONENTS INCLUDING
COMPRESSORS USED FOR
THEM
All of the Daikin
Group’s business
facilities and
subsidiaries in Japan
are certified under the
ISO 14001
international standard
for environment
management.
Daikin Australia
Pty Limited (ISO 9001)
QEC 23256 31 May 2006
Daikin Australia
Pty Limited (ISO 14001)
CEM20437 13 November 2006
Dealer
Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan
http://www.daikin.com/global_ac/
c All rights reserved
Printed in Japan 09/09/030 DN
Specifications, designs and other content appearing in this brochure are current as of September 2009 but subject to change without notice.