27" (69 cm) Gas Washer/Dryer
PRODUCT MODEL NUMBERS
WGT3300X
Dimensions/Clearances
Front View
Side View
47 / "
(1213 mm)
3 4
1
/4"
27.5
(692 mm)
Back View
271/4"
(692 mm)
26"
(660 mm)
11"
(279 mm)
3
/4"
71.5
(822 mm)
653/4"
(1670 mm)
713/4"
(1822 mm)
321/8"
(816 mm)
34"
(864 mm)
32"
(813 mm)
1"
(25 mm)
713/4"
(1822 mm)
14"
(356 mm)
411/4"
(1,048 mm) 351/4"
(895 mm)
261/2"
25"
(673 mm)
(635 mm)
1"
(25 mm)
1"
(25 mm)
Clearances
Side Clearances
(recommended/minimum)
Front/Back/Top
(recommended/minimum)
Recessed area or closet installation
12"
(305 mm)
48 in.2
(310 cm2)
Front
View
3"
(76 mm)
Closet
door
3"
(76 mm)
24 in.2
(155 cm2)
1"/0"
(25 mm/0 mm)
1"/0"
(25 mm/0 mm)
1"
(25 mm)
(Closet)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
5"
(127 mm)
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10356101C
10/2013
ELECTRICAL REQUIREMENTS
To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical
supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit
breaker is recommended. Connect to an individual branch circuit.
DRAIN SYSTEM
Drain system can be installed using a floor drain, wall standpipe,
floor standpipe, or laundry tub. Select method you need.
Floor standpipe drain system
Minimum diameter for a standpipe drain: 2" (51 mm). Minimum
carry-away capacity: 17 gal. (64 L) per minute. Top of standpipe
must be at least 39" (990 mm) high; install no higher than 96"
(2.4 m) from bottom of washer/dryer. If you must install higher
than 96" (2.4 m), you will need a sump pump system.
Floor drain system
Floor drain system requires a Siphon Break Kit (Part Number
285834), 2 Connector Kits (Part Number 285385), and an
Extension Drain Hose (Part Number 285863) that may be
purchased separately. See “Use and Care Guide” for ordering
details. Minimum siphon break: 28" (710 mm) from bottom of
washer/dryer. (Additional hoses may be needed.)
Laundry tub drain system
Minimum capacity: 20 gal. (76 L). Top of laundry tub must be
at least 39" (990 mm) above floor; install no higher than 96"
(2.4 m) from bottom of washer/dryer.
IMPORTANT: To avoid siphoning, no more than 4.5" (113 mm)
of drain hose should be inside standpipe or below the top of
wash tub. Secure drain hose with shipping strap.
Wall standpipe drain system
See requirements for floor standpipe drain system.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or flexible metal exhaust vent
must be used. Do not use plastic or metal foil vet. Exhaust hood
must be at least 12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Recommended Styles:
Acceptable Style:
Louvered hood
Box hood
Angled hood
The “Vent System Chart” provides venting requirements that
will help achieve best drying performance.
Vent System Chart
Number of
90° turns
or elbows
Type
of vent
Box/louvered
hoods
Angled
hoods
0
Rigid metal
37 ft. (11.3 m)
35 ft. (10.7 m)
1
Rigid metal
32 ft. (9.7 m)
27 ft. (8.2 m)
2
Rigid metal
24 ft. (7.3 m)
19 ft. (5.8 m)
NOTE: Side exhaust installations have a 90º turn inside the dryer.
To determine maximum exhaust length, add one 90º turn to the chart.