High Performance Power Protection
THE ENVIRONMENTALLY FRIENDLY POWER PROTECTION
TO PROTECT YOUR MISSION CRITICAL APPLICATIONS
EXCELLENCE IN
THE COMPANY
newave
ups systems
Newave UPS-Systems was established in 1993 in Switzerland and today it enjoys a worldwide reputation built on innovative power protection technology, superior product quality and excellent technical
support.
Our professional responsibility is to design Uninterruptible Power
Supplies (UPS) with highest reliability to safeguard mission-critical
applications and keep your business running.
Our moral responsibility is to design UPS products that protect our
environment from excessive heat, noise and harmonic emissions.
2
POWER PROTECTION
NEWAVE Milestones 1993-today
1993
Year of Establishment
1994
Design of first 1-phase transformerless UPS range 5-6kVA
1996
Manufacture of 1-phase tranformerless UPS range 10-20kVA
First NEWAVE presence at CEBIT 1996
1997
Manufacture 3-phase transformerless UPS range 10-60kVA
World Premiere
1998
First Certification ISO9001
1998
First parallel transformerless 3-phase system
World Premiere
2000
New Operation in Quartino
2001
Manufacture of first 3-phase Modular
Module sizes 10-40kVA
World Premiere
2002
Manufacture of 3-phase transformerless UPS range 80-120kVA
World Premiere
2003
Manufacture of first 3-phase transformerless UPS range 160-250kVA
World Premiere
2004
Manufacture of first 3-phase Modular
Module sizes 60-100kVA
World Premiere
Conceptpower
DPA
2005
Manufacture of first 3-phase transformerless UPS size 300kVA
2006
Manufacture of second generation 3-phase Modular UPS range 10-200kW in one rack
World Premiere
World Premiere
Conceptpower
Maxi
Conceptpower
Modular
Conceptpower
Maxi
Conceptpower
Conceptpower Midi & Maxi
Modular
Ecowave
re
utu
f
e
Th
Powerwave
Primewave
prese
The
nt
T he pa st
Newave SA ¦ Via Luserte Sud 9 ¦ CH-6572 Quartino ¦ Tel. +41 (91) 850 29 29 ¦ Fax +41 (91) 840 12 54 ¦ info@newave.ch ¦ www.newave.ch
LOW END
Products Overview
Low end power protection
PrimewavePlus 5-8kVA
Single phase (in/output 1/1-, 3/1)
Mid range power protection
PowerValueTM 7.5-40kVA
Single phase in/output (1/1) –7.5-12kVA
Three phase in, single phase output
(3/1) – 7.5-20kVA
Three phase in/output (3/3) –7.5-40kVA
High end power protection
Conceptpower Midi and Maxi 40-300kVA
Three phase in/output (3/3)
4
POWER PROTECTION
PrimewavePlus
Single phase power protection solution in the range of 5-8kVA
PrimewavePlus Technology
Why is PrimewavePlus outstanding?
Is not just an Uninterruptible Power Supply that achieves its basic function to provide highest power protection reliability for
mission-critical applications in the event of
power supply disturbances and outages. It
was specifically designed to meet the rapidly
changing requirements of the IT, telecom
and industrial applications. Innovative highfrequency double-conversion PrimewavePlus technology means high power availability and dramatic reduction of transportation,
start-up, operating and life-cycle cost - a saving which is passed on to the end user.
• Small and light design 8kVA
(w/o battery) = 37kg;
• Unique input stage design yielding
PF=0,98 and THDi <10% for all single
phase input models;
• User friendly LCD-Display for monitoring and control;
• 92% double-conversion efficiency and
99% in energy-efficient ecomode;
• Battery friendly ripple-free battery charger prevents shortening of battery life;
• High power supply availability through
RCC (Redundant Critical Circuits);
• Comprehensive monitoring and shutdown software with hardware and
software SNMP solutions.
Technical specifications:
PrimewavePlus 11 and 31
General Data
Output Rated Power
k VA
5
6
8
Topology
On-Line, Double Conversion
Output Power Factor
0.7
Input Data
Input Voltage single-phase
220V, 230V, 240V
Input Voltage three-phase
3x380/220V+N, 3x400/230V+N, 3x415/240V+N
Input Voltage Tolerance
3x400V/230V (–25% +10%)
Input Frequency
45 – 65 Hz
Input Power Factor
0.98 (for 1phase input models), 0.95 (for 3phase input models)
THD of Input Current
< 10% (for 1phase input models), < 25% (for 3phase input models)
Output Data
Output Voltage single-phase
220V, 230V, 240V
Output Frequency
50 / 60 Hz
Output Voltage Tolerance
static
+/– < 2%
at load step (0-100-0)
+/– < 5%
distorsion with non-linear load
+/– < 3%
Monitoring and Control Data
Crest Factor
3:1
Overload Capacity
110% 10 min., 125% 30 sec.
Communication Ports
RS 232 and volt-free contacts
Standa rds
EN 60950, EN 62040, EN 50091
Efficiency AC-AC
92% (on-line) and 99% (off-line)
Audible Noise
48 dBA (on-line)
Mechanical Data
Di mensi ons ( WxHxD)
mm
200x690x690
Weight (UPS with standard batteries)
kg
77
87
92
Specifications are subject to change without notice.
Newave SA ¦ Via Luserte Sud 9 ¦ CH-6572 Quartino ¦ Tel. +41 (91) 850 29 29 ¦ Fax +41 (91) 840 12 54 ¦ info@newave.ch ¦ www.newave.ch
MID RANGE
PowerValue 7.5-40kVA
The Beauty of Power Protection Simplicity
Medium-sized power protection range with outstanding price / performance capability
PowerValueTM represents an accurately balanced combination of unmatched reliability, excellent electrical performance, exceptionally compact size and outstanding cost-efficiency housed in an attractive enclosure.
PowerValueTM is a third-generation transformer-less double-conversion (VFI) power protection technology designed to protect a wide area of critical applications including server
rooms, networks, telecommunication systems, industrial processes and medical equipment.
Cabinet A:
Up to 15kVA with 10min
Outstanding power and back-up time density
PowerValueTM addresses mid-sized server rooms, networks, telecommunication systems, industrial processes and medical equipment where higher cost parallelable or scalable power
protection solutions are not required. Furthermore, as PowerValueTM provides increased
protection security and efficiency it can be used instead of multiple separate, smaller units
spread throughout a facility.
The uniqueness of the PowerValueTM design lies in its technical simplicity which is based on
Newave’s transformerless, double-conversion (VFI=Voltage Frequency Independent) technology with unmatched reliability.
Cabinet B:
Up to 40kVA with 10min
PowerValueTM is available in a variety of models and input/output configurations:
• PowerValueTM (1phase input and 1phase output), 7.5, 10 and 12kVA
• PowerValueTM (3phase input and 1phase output), 7.5, 10, 15 and 20kVA
• PowerValueTM (3phase input and 3phase output), 7.5, 10, 15, 20, 30 and 40kVA
Features and benefits:
Provides more power protection value at a more affordable price
PowerValueTM has been designed to provide an optimised price/performance ratio. A number of exceptional features have been carefully selected and built into the PowerValueTM without a substantial
increase of material contents in order to optimize both performance
and cost benefits. The high power protection value of this new generation of medium-sized UPS’s raises PowerValueTM to the best-valuein-the-category UPS.
Cabinet C:
Up to 40kVA with 20min
and input frequency window (35-70Hz) allows high power availability
even in environments where input power supply is unstable and substandard. Battery usage is minimised.
Low Cost of Ownership:
Thanks to Energy Saving Inverter Switching (ESIS) high double conversion efficiencies (up to 95%) are achieved.
Input features:
PowerValueTM 11:
PF=0.98 and THDI =7-9%
PowerValueTM 31:
PF=0.98 and THDI =7-9%*
PowerValueTM 33:
PF=0.98 and THDI =7-9%*
(*) Optional (standard PF=0.95 THDI <25%)
Continuous Uptime:
Highest reliability is provided through mature, on-line double conversion, transformer-less technology. Built-in reliability with redundant
power supply, reduced cable harness, improved cooling of critical
components.
Space Saving:
Smallest foot-print and weight:
15kVA (3/3) = 0.26 m2, weight w/o batteries = 75kg
40kVA (3/3) = 0.37 m2, weight w/o batteries = 154kg
Low Audible Noise:
Variable load-dependent DC-fan-speed reduces the audible noise, so
that the UPS can be operated in office environments.
Integration in Networks:
PowerValueTM has advanced monitoring and communication capabilities to keep you in constant command of your critical power protection system.
Cost Saving:
Outstanding power and back-up-time density:
• Cabinet A (WXHXD): 340x820x800mm: 15kVA(3/3) with batt. 10 min.
• Cabinet B (WXHXD): 450x1250x860mm: 40kVA(3/3) with batt. 10 min.
• Cabinet C (WXHXD): 550x1650x890mm: 40kVA(3/3) with batt. 20 min.
Additional battery cabinets will rarely be necessary.
Protects Your Environment:
PowerValueTM protects not only critical applications but also our
environment. It is a true environmentally friendly UPS with limited
hardware components (saving natural resources).
High Power Availability:
Wide input voltage window (up to –40% for loads less than 60%)
6
POWER PROTECTION
Interfaces:
User friendly, easy to install and easy to commission
Interfaces for cabinet A, B and C
PowerValueTM is a user-friendly UPS which
is easy to install and commission. In the
following pictures the various interfaces of
the UPS are illustrated:
User friendly Control Panel is composed of:
A: mimic Diagram
B: LCD-Display
C: keyboard
SNMP-Slot
Cooling Fans
SNMP-Slot
Dry Port
Smart Port RS 232
Dry Port
Smart Port RS 232
Input/battery fuses
Input/battery/bypass fuses
Manual bypass and
Output breaker
Bypass fuses
Manual bypass and
Output breaker
Rollers/Castors
Rollers/Castors
Front View
Cabinet B*
Front View
Cabinet A
Rear View
Cabinet A
Rear View
Cabinet B*
* The position of the interfaces on the larger cabinet C are equivalent to cabinet B
Battery flexibility:
outstanding compact size with capability of supplying longer back-up times
without the need of extra battery
cabinets
PowerValueTM is provided in three cabinet
sizes in order to allow longer battery backup times and therefore avoid the use of additional battery cabinets. All PowerValueTM
are equipped with a 6Amp ripple-free battery charger that protects batteries and delays
their aging process. Optional temperaturedependent charging function is provided, as
well as a optional battery charger to reduce
the recharge times.
The advanced Battery Monitoring and Management algorithm monitors the battery
continuously and in the unlikely event of a
battery fault an early warning will be triggered.
Battery configurations:
Cabinet type*
A
B
C
Maximum Battery
Configuration
50x 9Ah
3 x 48 x 9Ah
2 x 40 x 28Ah
UPS Rating
(kVA)
Maximum Back-up
(min.) with 100% load
26 (PF=0.8)
30 (PF=0.7)
7.5
18 (PF=0.8)
23 (PF=0.7)
10
14 (PF=0.8)
18 (PF=0.7)
12
11 (PF=0.8)
13 (PF=0.7)
15
90 (PF=0.8)
103 (PF=0.7)
7.5
66 (PF=0.8)
78 (PF=0.7)
10
52 (PF=0.8)
62 (PF=0.7)
12
45 (PF=0.8)
46 (PF=0.7)
15
33 (PF=0.8)
38 (PF=0.7)
20
17 (PF=0.8)
30
12 (PF=0.8)
40
130 (PF=0.8)
10
82 (PF=0.8)
15
60 (PF=0.8)
20
35 (PF=0.8)
30
22 (PF=0.8)
40
* Cabinet (WxHxD): A 340 x 820 x 800mm / B 450 x 1250 x 860mm / C 550 x 1650 x 890mm
Newave SA ¦ Via Luserte Sud 9 ¦ CH-6572 Quartino ¦ Tel. +41 (91) 850 29 29 ¦ Fax +41 (91) 840 12 54 ¦ info@newave.ch ¦ www.newave.ch
MID RANGE
Technical specifications:
PowerValueTM 11 and 31
General Data
Model
Output Rated Power
1-phase in/output (11)
kVA
7.5
10
12
3-phase input / 1-phase output (31)
7.5
10
Output Power Factor
0.7
Topology
On-Line, Double Conversion (VFI)
Construction
Stand-alone
Static and Maintenance Bypass
standard
Cable entry
Cabinet A from rear
15
20
Cabinet B and C from front
Efficiency (Double Conversion)
Audible Noise With100%/50% Load
Up to 95%
dBA
Standa rds
50 / 48
50 / 48
50 / 48
53 / 49 53 / 49
EN 60950, EN 62040, EN 50091
Input Data
Input Voltage
1x220/230/240+N,
3x380/220V+N, 3x400/230V+N, 3x415/240V+N
Input Voltage Tolerance (Ref. to 3x400/230V)
For loads <100% (-23%, +15%), <80% (-30%, +15%), <60% (-40%, +15%)
Input Frequency
35 – 70Hz
Input Power Factor ( electrically regulated)
0.98
Input Current Form
THDI = 7-9%
Inrush Current
Soft start
Input Cabling
Hard wired
0.95 standard (0.98 optional)
THDI <25% standard (THDI = 7-9% optional)
Output Data
Output Voltage
1x220/230/240+N
Output Voltage Tolerance
+/- 1% (linear load), +/- 3 (non-linear load)
Output Voltage Tolerance (Load Jumps 0-100% and 100-0%)%
+/- 4%
Output Frequency
50 or 60Hz
Output Frequency Tolerance
+/- 0.1 (free-running), +/- 4 (with mains, adjustable)
Crest Factor
3:1
Overload
150% for 1min., 125% for 10min.
Monitoring and Control Data
Power Management Display (PMD)
With LCD, Mimic Diagram, Control
Communication port (Smart Port)
Serial RS 232
Communication port (Dry Port)
Volt-free relays
SNMP
Yes
Shutdown and Monitoring Software
Yes (Wavemon)
Mechanical Data
Size PowerValue Cabinet A (WxHxD)
mm
340 x 820 x 800 (for 7.5 - 15kVA)
Weight PowerValue Cabinet A w/out batteries
kg
75 (for 7.5 - 15kVA)
Size PowerValue Cabinet B (WxHxD)
mm 450 x 1250 x 860 (for 7.5 - 20kVA)
Weight PowerValue Cabinet B w/out batteries
kg
154 (for 7.5 - 20kVA)
Size PowerValue Cabinet C (WxHxD)
mm
550 x 1650 x 890 (for 7.5 - 20kVA)
Weight PowerValue Cabinet C w/out batteries
kg
204 (for 7.5 - 20kVA)
Specifications are subject to change without notice.
8
POWER PROTECTION
Technical specifications:
PowerValueTM 33
General Data
Output Rated Power
kVA
7.5
10
15
Output Power Factor
0.8
Topology
On-Line, Double Conversion (VFI)
Construction
Stand-alone
Static and Maintenance Bypass
standard
Cable entry
Cabinet A from rear
20
30
53 / 49
59 / 51
40
Cabinet B and C from front
Efficiency (Double Conversion)
Audible Noise With 100%/50% Load
Up to 95%
dBA
Standa rds
50 / 48
50 / 48
53 / 49
63 / 53
EN 60950, EN 62040, EN 50091
Input Data
Input Voltage
3x380/220V+N, 3x400V/230V+N, 3x415/240V+N
Input Voltage Tolerance (Ref. to 3x400/230V)
For loads <100% (-23%, +15%), <80% (-30%, +15%), <60% (-40%, +15%)
Input Frequency
35 – 70Hz
Input Power Factor ( electrically regulated)
0.95 standard (0.98 optional)
Input Current Form
THDI <25% standard (THDI = 7-9% optional)
Inrush Current
Soft start
Input Cabling
Hardwired
Output Data
Output Voltage
3x380/220V+N, 3x400V/230V+N, 3x415/240V+N
Output Voltage Tolerance
+/- 1% (linear load), +/- 3 (non-linear load)
Output Voltage Tolerance (Load Jumps 0-100% and 100-0%)%
+/- 4%
Output Frequency
50 or 60Hz
Output Frequency Tolerance
+/- 0.1 (free-running), +/- 4 (with mains, adjustable)
Crest Factor
3:1
Overload
150% for 1min., 125% for 10min.
Permissible Unbalanced Load
100% (all 3 phases regulated independently)
Monitoring and Control Data
Power Management Display (PMD)
With LCD, Mimic Diagram, Control
Communication port (Smart Port)
Serial RS 232
Communication port (Dry Port)
Volt-free relays
SNMP
Yes
Shutdown and Monitoring Software
Yes (Wavemon)
Mechanical Data
Size PowerValue Cabinet A (WxHxD)
mm
340 x 820 x 800 ( for 7.5 - 15kVA)
Weight PowerValue Cabinet A w/out batteries
kg
75 ( for 7.5 - 15kVA)
Size PowerValue Cabinet B (WxHxD)
mm
450 x 1250 x 860 ( for 7.5 - 40kVA)
Weight PowerValue Cabinet B w/out batteries
kg
154 ( for 7.5 - 40kVA)
Size PowerValue Cabinet C (WxHxD)
mm
550 x 1650 x 890 ( for 7.5 - 40kVA)
Weight PowerValue Cabinet C w/out batteries
kg
204 ( for 7.5 - 40kVA)
Specifications are subject to change without notice.
Newave SA ¦ Via Luserte Sud 9 ¦ CH-6572 Quartino ¦ Tel. +41 (91) 850 29 29 ¦ Fax +41 (91) 840 12 54 ¦ info@newave.ch ¦ www.newave.ch
HIGH END
Conceptpower™ 60-300kVA
Second generation transformerless three phase UPS in the range 60-300kVA
protects your mission critical load and your environment
Large and heavy traditional UPS systems have been in the market for a long time. Big and bulky accessories like 12pulse rectifiers and input
harmonic filters are used to improve the input power factor and the input current THD in order not to pollute the mains. The consequences
are increased expensive floor-space, increased power losses throughout the lifecycle of the UPS and increased audible noise.
In the past decade we have experienced very modest qualitative technological improvements with clear end-user benefits in the area of high
power UPS’s. Environmentally conscious customers today are not only demanding highest power protection availability but also systems that
are environmentally friendly and ensure low cost of ownership.
Protects not only your critical load but also your environment during the entire
UPS lifecycle.
Infinitely expandable
ConceptpowerTM is an advanced double conversion, VFI (Voltage and Frequency Independent) technology that responds fully to
both highest availability and environmentally
friendly requirements. In other words the
ConceptpowerTM simultaneously protects
your critical load and your environment.
Furthermore your cost of ownership will
be low during the entire lifecycle of the UPS
system. Thanks to the unique and highest
threephase double conversion efficiency,
low mains harmonic pollution, low audible noise and optimized material contents
ConceptpowerTM is a true green UPS. The
proven Newave double conversion technology guarantees highest reliability and unmatched electrical performance. If we add to
the above features the unique Distributed
Parallel Architecture (DPA) for redundancy
and for extension of power capacity it will
complete the picture of this exciting power
protection system.
Midi 60kVA
Maxi 100-120kVA
10
Midi 80kVA
Maxi 160-300kVA
POWER PROTECTION
Features and benefits:
Choice of the best Power Protection Solution
Conventional technology
Transformer-less ConceptpowerTM
Transformer-based
Traditional UPS
Advanced Double Conversion technology
with Unique Distributed Parallel Architecture
(DPA) without single points of failure
and infinitely expandable capability
guarantees highest availability.
Conventional Double Conversion technology with output
transformer. Limited number
of parallelable UPS-units
(up to 4-9).
Tr ansportation Cost Saving
Compact and light UPS (250kVA=660kg).
Reduced freight, bringing-in and manoeuvering cost.
Typical weight of UPS 250kVA:
- 1200 kg for 6 pulse models
- 1800 kg for 12 pulse models
Energy Cost Saving
High Double Conversion Efficiency
(up to 96%) thanks to advanced
transformerless technology with ESIS
(Energy Saving Inverter Switching).
Low Double Conversion
Efficiency (up to 93%)
resulting in higher
running cost.
Very reduced foot-print.
40kVA = 0.42 m2
80kVA = 0.435 m2
120kVA= 0.52 m2
300kVA= 0.9 m2
Typical foot-print:
40kVA = 0.64 m2
80kVA = 0.8 m2
120kVA = 0.88 m2
300kVA = 1.8 m2
Sinewave Input Current (THD<7%) and
PF=0.98 means smaller installation cost
due to reduced cable/fuse ratings.
Typical THD>30% and PF=0.8
means it is necessary to add
expensive 12pulse rectifiers
with bulky transformers
and/or input harmonic filters.
Flexible Battery Management (FBM) with
variable DC-voltage enabling the use of
variable number of battery blocks to exactly
match the requested battery autonomy.
Further more the Ripple-free battery charger
protects your battery from excessive
temperatures.
Lack of flexibility due to a
fixed number of battery
blocks (typically 32 battery
blocks of 12V).
Every standard unit is provided with the
parallel hardware and no on-site time
consuming upgrade is necessary.
Typically the standard units
are not provided with the
parallel hardware and therefore
expensive on-site time consuming upgrade is necessary.
Down-time Cost Saving
Floor-Space Cost Saving
Installation Cost Saving
Battery Cost Saving
Power Extension Cost Saving
Newave SA ¦ Via Luserte Sud 9 ¦ CH-6572 Quartino ¦ Tel. +41 (91) 850 29 29 ¦ Fax +41 (91) 840 12 54 ¦ info@newave.ch ¦ www.newave.ch
HIGH END
Environmental concept:
Keep a constant eye on your environment and your cost of ownership
ConceptpowerTM was designed to meet also important environmental demands and to focus
on the cost of ownership of a power protection infrastructure. Features like low heat emission, low level of harmonic pollution or low level audible pollution are part of the Power
Protection Concept (PPC) and have been built into the ConceptpowerTM design.
High Efficiency
100 %
High ConceptpowerTM efficiency means low heat emission and therefore
no unnecessary overheating of our environment. In addition to that, low
losses means less energy consumption, which can differ substantially from
one product technology to another. Furthermore the heat must always
be evacuated by cooling systems, which must be sized to the amount of
losses emitted by the UPS’s. That is also a cost that must be considered
during the entire lifecycle of the UPS. Thanks to the transformerless technology and the unique ESIS (Energy Saving Inverter Switching) Technology the ConceptpowerTM reaches double conversion efficiencies of up to
96%. This advanced high efficiency design has in average at least 5% higher
efficiency than equivalent traditional double-conversion designs and has
similar efficiency compared to single conversion technologies.
90
80
70
60
cos =0.8
cos =1
SMPS
efficiency
50
0
load
25
50
75
100 %
High Input Power Factor/Sinewave Input Current
Input Voltage
Input Current
The near to one input power factor of ConceptpowerTM reduces the input
installation cost by using smaller cable sections and smaller fuse sizes.
Thanks to the low input current THDI = 7-9% (sinewave input current)
the level of harmonic pollution of the ConceptpowerTM is very low. The
low harmonic emission into the mains saves unnecessary oversizing of the
gen-sets. The near to one input power factor and the low input current
THDI = 7-9% of ConceptpowerTM are electronically regulated and
there is therefore no need for expensive filtering or 12pulse rectification
like in traditional double conversion topologies.
Low Audible Noise
With its low audible noise ConceptpowerTM is a very comforting UPS that does not disturb the working environment. Thanks to the load
dependent noise level regulation the noise level is even more reduced when the load is < 70% of the UPS’s rated power.
Battery Protection and Battery Management
ConceptpowerTM is provided with a unique ripple-free battery harger that protects the battery from overheating and consequently increases
the battery lifecycle. A further battery protection feature is the temperature regulated battery charge voltage.
The battery charger automatically regulates the battery charge voltage as the ambient temperature changes. The built-in Flexible Battery
Management (FBM) periodically and automatically checks the fitness of the battery and alerts immediately if any anomaly appears. The FBM
allows the use of various numbers (40-50) of battery blocks to provide the exact battery runtime and thus optimize battery cost.
12
POWER PROTECTION
Technical specifications:
Conceptpower 60-300 kVA
General Data
Output Rated Power
Maxi
Midi
kVA
60
80
100
120
160
Output Power Factor
0.8
Topology
On-Line, Double Conversion, VFI
Parallel Technology
Distributed Parallel Architecture
Redundancy n+1
High reliability, no limitation of paralleling
Capacity Upgrade
Add your power as you grow (no limitation)
Static and Maintenance Bypass
standa rd
Accessibility
Front and rear accessible for service and maintenance
200
250
300
(no need for side or top access)
Efficiency (Double Conversion)
Audible Noise With 100%/75% Load
Up to 96%
dBA
Standa rds
59 / 54
69 / 63
69 / 63
69 / 63
73 / 70
73 / 70
73 / 70
75 / 72
EN 60950, EN 62040, EN 50091
Input Data
Input Voltage
3x380/220V+N, 3x400/230V+N, 3x415/240V+N
Input Voltage Tolerance (Ref. to 3x400/230V)
For loads <100% (-23%, +15%), <80% (-30%, +15%), <60% (-40%, +15%)
Input Frequency
35 – 70Hz
Input Power Factor
0.98 (electrically regulated)
Input Current Form (Sinewave)
Sinewave THDI = 7-9% at 100% load
Inrush Current
Soft start
Input Cabling
Hardwired
Output Data
Output Voltage
3x380/220V+N, 3x400/230V+N, 3x415/240V+N
Output Voltage Tolerance
+/- 1% (linear load), +/- 3% (non-linear load)
Output Voltage Tolerance (Load Jumps 0-100-0%)
+/- 4%
Output Frequency
50 or 60Hz
Output Frequency Tolerance
+/- 0.1% (free-running), +/- 4% (with mains, adjustable)
Crest Factor
3:1
Overload
150% for 1min., 125% for 10min.
Permissible Unbalanced Load
100% (all 3 phases regulated independently)
Monitoring and Control Data
Power Management Display (PMD)
With LCD, Mimic Diagram, Control
Communication port (Smart Port)
Serial RS 232
Communication port (Dry Port)
Volt-free relays
SNMP
Yes
Shutdown and Monitoring Software
Yes (Wavemon)
Emergency Power Off (EPO)
Yes
Mechanical Data
Size Conceptpower Frame (WxHxD
mm
Size Additional Battery Frame (WxHxD)
mm
Weight Conceptpower (Without batteries)
kg
580 x
1400 x 750
190
580 x
1800 x 750
240
1200 x 1900 x 750
700 x 1800 x 750
580 x 1800 x 750
330
350
(on request)
620
640
660
735
Specifications are subject to change without notice.
Newave SA ¦ Via Luserte Sud 9 ¦ CH-6572 Quartino ¦ Tel. +41 (91) 850 29 29 ¦ Fax +41 (91) 840 12 54 ¦ info@newave.ch ¦ www.newave.ch
DATA PROTECTION
Connectivity concept:
Integrated Power Management Solutions
Power Management Solutions:
Parallel Handling:
• Environmental Monitoring
• Integration in Network Management
System
• Integration in building Management
System
• ModBus interface
• Remote Monitoring System through
web
• Remote Monitoring System with SNMP
• Redundant UPS Monitoring
• Integration in Multivendor/Multiplatform
environments
• Extensive alarm handling/Dispatching
When a customer buys a UPS he buys security for a critical mission. When a customer
buys a parallel redundant system, he buys
even more security. Consequently a parallel system is now considered and handled
as “a whole”. Critical measurement values,
for instance “battery autonomy”, are calculated and expressed for the global system.
A shutdown is not introduced as long as the
parallel system is able to sustain the current
load demand. Alarms are not dispatched
unless the system really reaches a critical
situation.
This functionallity is based on our multidrop
solution.
Or
Products Portfolio:
• Wavemon (UpsMan, UpsMon, RCCMD),
Management and shutdown solution
for Multiplatforms and heterogeneous
networks, including parallel handling capability;
• UNMS (UPS Network Management System), custom solution for integrated
management;
• SNMP Interfaces, available as slot Card
or external Box, includes parallel handling capability;
• Modbus solution: standard via TCP/IP; as
option via RS485;
• Modem interface;
• TempMan, temperature interface (AUX
device);
• RSP Remote Signalling Panel, working on
dry contacts;
• Switch Box, to duplicate the potential
free contacts of the UPS;
• Site switch, management of 4 independent power outlets (SS4 AUX).
Wavemon Display:
Events, alarms, messages dispatching:
Actions: 1 line for each event
- Event list
Parallel units up
to 6 Modules
Wavemon CD:
SNMP Box & Card:
Very exclusive functionality available on our
SNMP-Interfaces (Card or Box) - Modbus,
Environment Interface, Modem support the new SNMP Solutions integrates the parallel handling capability.
SNMP Card
SNMP Box
14
A comprehensive set of applications. Managemgent and Shutdown Solutions for heterogeneous networks.
Wavemon Communication interface
(UpsMan) and graphical user interface (UpsMon) for the management of one UPS system. UpsMan has similar functionality like
the SNMP interface. Includes parallel handling capability.
UNMS (UPS Network Management
System), for Windows. Customizable solution for the management of SNMP interfaced UPS’s.
RCCMD shutdown client, controlled by
UpsMan or SNMP-interface. Available for
a diversity of operating systems allowing
a shutdown solution on heterogeneous
networks.
SNAP IN for
HP Openview.
SHUTDOWN AND MONITORING SOLUTIONS
Select your connectivity solution:
System values (parallel) and
single units values
Ethernet
10/100 Mbps
Web-Browser:
system values and
Telnet
RCCMD 2
Server
SNMP
System values only.
Old style graphical
interface
S tandard on
TCP-IP
1x*
SNMP
Card
Option
on RS485
NM
Network Management
System e.g. HP
Openview, Tivoli,
Unicenter
Modem
(option)
Or
Or
1x
SNMP
Box
Or
**
Or
System values (parallel)
and single units values:
S N M P Agent
Or
AUX
RS232
TCP-IP
SNMP
NW Protocol
(serial RS232)
RCCMD
RS485
bility
Servicea
form
iplat
Mult
rated
Integ ns
io
Solut
ndling
Parallel Ha
ous
ogene
Heter ork
netw
Serial communication (UPS protocol)
Protocol, complete data set is transferred
Standard protocol, RFC1628. Partial data
set. UPS System is seen as a global.
Remote Commands
For optional Modbus
*
It is possible to use NxSNMP Cards for redundancy,
renouncing on parallel handling capability
**
Serial “duplicator” (pipe-through), with limited capabilities
(only basic values are available)
UPSMon
User Interface: Graphical user interface for
all Windows Oss
UPSMan
Interface Module: Data collection, event
log and alarm dispatching for all common
Oss
RCCMD
Remote Console Commands: Remote
execution of management commands
(Cross platform). Shutdown and more
Configuration facility for the SNMP Interface
Dispatching of events, alarms, messages. Based on scripts.
Functionality available on the SNMP Interface and
UPSMan. Based on Network services (mail server, etc.).
Greatly configurable ( ).
For additional information see www.newave.ch
Newave SA ¦ Via Luserte Sud 9 ¦ CH-6572 Quartino ¦ Tel. +41 (91) 850 29 29 ¦ Fax +41 (91) 840 12 54 ¦ info@newave.ch ¦ www.newave.ch
The following are just some of the companies using the products and services of
Newave SA:
Henkel
Hewlett Packard
Hilti
Hilton
Honeywell
Hyatt
IBERIA
IBM
Intel
Iran Insurance
Karafarin Bank
Lekkerland
Lloyds TSB
LuK
LUKOIL
Meridien
Meteorological Office
Metropolitana Lisboa
Mobile TeleSystems
(MTS)
Mobistar
Motorola
NATs (National Air
Traffic control)
Nestlè
Novartis
Nuffield Hospitals
Oracle Corporation
OSCE Kosova
Oxford University
Paulaner
Procter & Gamble
Rabo Bank
Radio Televisión
Española
REPSOL-YPF
Ritz
Rohde & Schwarz
ROS Telecom
Royal Bank of Scotland
Royal Scandinavia
Russian Railways
SBB Zürich
Scottish Power
Sheraton
Siemens Schweiz AG
Swiss Reinsurance
TCI (Telecommunication of IRAN)
Technion
Tedjarat Bank
United Bank of
Switzerland(UBS)
Vneshtorgbank
Vodafone
Williams
Winterthur-Assurance
p.a. wincasa
Zürcher Kantonalbank
Newave SA
Via Luserte Sud 9
6572 Quartino
Switzerland
Tel. +41 (91) 850 29 29 - Fax +41 (91) 840 12 54
info@newave.ch
www.newave.ch - www.newaveups.com
Newave SA ¦ Via Luserte Sud 9 ¦ CH-6572 Quartino ¦ Tel. +41 (91) 850 29 29 ¦ Fax +41 (91) 840 12 54 ¦ info@newave.ch ¦ www.newave.ch
www.visual360.ch
Acer
AEG SVS
American British
Racing
American Express
Ansar Almojahedin
Asea Brown Boveri
AXA Insurance
Bank Vontobel AG
Barclays Bank
Basijian Institute
Basler Versicherung
BBC (British Broadcasting Corp.)
Belgorodenergo
Benning
Betty Barclay
Biz Basel
BNFL (British Nuclear
Fuels Ltd.)
British Airport Authority (BAA)
British Council
British Telecom
Cable and Wireless
Cambridge University
Caterpillar
Central Bank of Russian Federation
Cepsa
Coca Cola
Core Telecom
Correos de España
Credit Suisse
Dachser
Danfoss
Deutsche Bank
Deutsche Post
Fujitsu
Gestamp Corporation
Glaxo Smith Kline