ELECTRIC DRYER INSTALLATION INSTRUCTIONS

U.S.A. ONLY

Para una versión de estas instrucciones en español, visite www.Whirlpool.com

TABLE OF CONTENTS

DRYER SAFETY..............................................................................1

INSTALLATION REQUIREMENTS ................................................2

Tools and Parts ............................................................................2

Optional Equipment .....................................................................3

Location Requirements................................................................3

ELECTRIC DRYER POWER HOOKUP .........................................5

Electrical Requirements ...............................................................5

Electrical Connection ...................................................................6

VENTING .......................................................................................11

Venting Requirements................................................................11

Plan Vent System .......................................................................12

Install Vent System.....................................................................13

INSTALL LEVELING LEGS...........................................................13

CONNECT VENT...........................................................................14

CONNECT INLET HOSE (STEAM MODELS)..............................14

LEVEL DRYER ..............................................................................15

COMPLETE INSTALLATION .......................................................15

TROUBLESHOOTING ..................................................................15

DRYER SAFETY

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”

These words mean:

DANGER

You can be killed or seriously injured if you don't immediately follow instructions.

WARNING

You can be killed or seriously injured if you don't follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

W10471644B

W10471646B - SP

2

INSTALLATION REQUIREMENTS

Steam Models

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Flat-blade screwdriver

#2 Phillips screwdriver

Adjustable wrench that opens to 1" (25 mm) or hex-head socket wrench

(for adjusting dryer feet)

Level

Wire stripper (direct wire installations)

Vent clamps

Caulking gun and compound

(for installing new exhaust vent)

Tin snips (new vent installations)

1/4" nut driver

(recommended)

Tape measure

Pliers

A. Leveling legs (4)

B. “Y” connector

C. Short inlet hose

D. Long inlet hose

E. Rubber washer

Parts supplied

Non-Steam Models

Remove parts package from dryer drum. Check that all parts are included.

NOTE: Do not use leveling legs supplied with dryer if installing on a pedestal.

4 Leveling legs

Remove parts package from dryer drum. Check that all parts are included.

NOTE: Do not use leveling legs supplied with dryer if installing on a pedestal.

Parts needed

Check local codes. Check existing electrical supply and venting.

See “Electrical Requirements” and “Venting Requirements” before purchasing parts.

Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom you purchased your dryer. For further information, please refer to the “Assistance or Service” section in your Use and Care Guide.

Optional Equipment

Refer to your Use and Care guide for information about the accessories available for your dryer.

Location Requirements

Installation clearances

The location must be large enough to allow the dryer door to open fully.

Dryer Dimensions

D

A

B

C

You will need

■ A location that allows for proper exhaust installation. See

“Venting Requirements.”

A separate 30-amp circuit.

If you are using a power supply cord, a grounded electrical outlet located within 2 ft (610 mm) of either side of the dryer.

See “Electrical Requirements.”

A sturdy floor to support the total dryer weight of 200 lbs

(90.7 kg). The combined weight of a companion appliance should also be considered.

A level floor with a maximum slope of 1" (25 mm) under entire dryer. If slope is greater than 1" (25 mm), install Extended Dryer

Feet Kit, Part Number 279810. Clothes may not tumble properly and automatic sensor cycles may not operate correctly if dryer is not level.

For a garage installation, you will need to place the dryer at least

18" (460 mm) above the floor. If using a pedestal, you will need

18" (460 mm) to the bottom of the dryer.

Steam models only: Cold water faucets located within

4 ft (1.2 m) of the dryer, and water pressure of 20-100 psi

(137.9-689.6 kPa). You may use the cold water supply from your washer using the “Y” connector provided.

Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic sensor cycle. This can result in longer drying times.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

A

B

C

D

Steam

(Electric or Gas)

38" (965 mm)

32 9 /

16

" (827 mm)

27" (686 mm)

52 9 /

16

" (1335 mm)

Non-Steam

(Electric or Gas)

38" (965 mm)

31 1 /

2

" (800 mm)

27" (686 mm)

51 1 /

2

" (1308 mm)

NOTE: Most installations require a minimum 5" (127 mm) clearance behind the dryer for the exhaust vent with elbow.

Venting Dimensions

C

A*

A

Steam

(Electric or Gas)

1" (25 mm)

Back View

B

Non-Steam

(Electric or Gas)

1" (25 mm)

B

C

14" (356 mm)

3 7 /

16

" (87 mm)

14" (356 mm)

3 7 /

16

" (87 mm)

* Dimension A is approximate, depending on when the diamond

marking on the leveling foot is no longer visible.

3

Closet installation - Dryer only

(460 mm)

C

A

B

Side View

Steam

(Electric or Gas)

Non-Steam

(Electric or Gas)

A*

B

1" (25 mm)

7 5 /

8

" (194 mm)

1" (25 mm)

7 5 /

8

" (194 mm)

C 3 3 /

8

" (86 mm) 3 3 /

8

" (86 mm)

* Dimension A is approximate, depending on when the diamond

marking on the leveling foot is no longer visible.

See “Venting Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this dryer.

This dryer has been tested for spacing of 0" (0 mm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:

■ Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door, and floor moldings.

Additional spacing should be considered on all sides of the dryer to reduce noise transfer.

■ For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

■ Companion appliance spacing should also be considered.

Custom undercounter installation - Dryer only

A

C* D E*

A

B

C*

D

E*

Steam

(Electric or Gas)

0" (0 mm)

38" (965 mm)

1" (25 mm)

27" (686 mm)

1" (25 mm)

Non-Steam

(Electric or Gas)

0" (0 mm)

38" (965 mm)

1" (25 mm)

27" (686 mm)

1" (25 mm)

*Required spacing

NOTE: Some models are not recommended for undercounter installation.

4

B

A* B

Side view

C**

Closet door with vents

A*

B

C**

Steam

(Electric or Gas)

1" (25 mm)

32 9 /

16

" (827 mm)

5" (127 mm)

Non-Steam

(Electric or Gas)

1" (25 mm)

31 1 /

2

" (800 mm)

5" (127 mm)

*Required spacing

**For side or bottom venting, 0" (0 mm) spacing is allowed.

Recessed or closet installation - Dryer on pedesta l

(460 mm)

A B C D* E F**

A

B

C

D*

E

F**

Steam

(Electric or Gas)

1" (25 mm)

27" (686 mm)

1" (25 mm)

1" (25 mm)

32 9 /

16

" (827 mm)

5" (127 mm)

Non-Steam

(Electric or Gas)

1" (25 mm)

27" (686 mm)

1" (25 mm)

1" (25 mm)

31 1 /

2

" (800 mm)

5" (127 mm)

*Required spacing

**For side or bottom venting, 0" (0 mm) spacing is allowed

NOTE: Some models are not recommended for recessed or closet installation.

Recommended installation spacing for cabinet installation

NOTE: Some models are not recommended for cabinet installation.

■ For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required.

A*

B*

6"* (152 mm)

76"

(1930 mm)

D** E F* G H I

I

H

A*

B*

C*

D**

E

F*

G

Steam

(Electric or Gas)

7" (178 mm)

7" (178 mm)

9" (229 mm)

5" (127 mm)

32 9 /

16

" (827 mm)

1" (25 mm)

1" (25 mm)

27" (686 mm)

1" (25 mm)

Non-Steam

(Electric or Gas)

7" (178 mm)

7" (178 mm)

9" (229 mm)

5" (127 mm)

31 1 /

2

" (800 mm)

1" (25 mm)

1" (25 mm)

27" (686 mm)

1" (25 mm)

*Required spacing

**For side or bottom venting, 0" (0 mm) spacing is allowed.

Recommended installation spacing for recessed or closet installation, with stacked washer and dryer

The dimensions shown are for the recommended spacing.

48 in.

2

(310 cm

*

2

)

3"* (76 mm)

C*

A* 1"

(25 mm)

27"

(686 mm)

1"

(25 mm)

A*

Steam

(Electric or Gas)

5 ½" (140 mm)

Non-Steam

(Electric or Gas)

5" (127 mm)

*Required spacing

NOTE: Some models are not recommended for stacked recessed or closet installation.

Mobile home - Additional installation requirements

This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety

Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for

Mobile Home Construction and Safety, Title 24, HUD Part 280) or

Standard CAN/CSA-Z240 MH.

Mobile home installations require:

All Dryers:

■ Metal exhaust system hardware, which is available for purchase from your dealer.

■ Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.

ELECTRIC DRYER POWER

HOOKUP

Electrical Requirements

It is your responsibility

■ To contact a qualified electrical installer.

■ To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70 latest edition and all local codes and ordinances.

The National Electrical Code requires a 4-wire power supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.

A copy of the above code standards can be obtained from:

National Fire Protection Association, One Batterymarch Park,

Quincy, MA 02269.

3"* (76 mm)

24 in.

2

(155 cm

*

2

)

1"* (25 mm)

5

■ To supply the required 3 or 4 wire, single phase, 120/240 volt,

60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A timedelay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.

Do not use an extension cord.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Electrical Connection

To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.

■ This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground conductor is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground conductor must be removed from the external ground connector (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground conductor is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.

If local codes do not permit the connection of a neutral ground wire to the neutral wire, see “Optional 3-wire connection” section.

A 4-wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors.

If using a power supply cord:

Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:

■ A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least

4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.

■ A UL listed strain relief.

If your outlet looks like this:

4-wire receptacle

(14-30R)

Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least

4 ft (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of

NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare.

The neutral conductor must be identified by a white cover.

If your outlet looks like this:

Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The

3-wire power supply cord, at least 4 ft (1.22 m) long, must have three 10-gauge copper wires and match a 3-wire receptacle of NEMA Type 10-30R.

3-wire receptacle

(10-30R)

If connecting by direct wire:

Power supply cable must match power supply (4-wire or 3-wire) and be:

Flexible armored cable or nonmetallic sheathed copper cable

(with ground wire), protected with flexible metallic conduit. All current-carrying wires must be insulated.

10-gauge solid copper wire (do not use aluminum) at least

5 ft (1.52 m) long.

Electrical Connection

1. Disconnect Power.

6

2. Remove the hold-down screw and terminal block cover.

C

D

B

Style 2: Direct wire strain relief

A

A. Neutral ground wire

B. External ground conductor screw

C. Center terminal block screw

D. Terminal block cover and hold-down screw

3. Install strain relief.

Style 1: Power supply cord strain relief

■ Remove the screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections into the hole below the terminal block opening so that one tab is pointing up and the other is pointing down, and hold in place. Tighten strain relief screws enough to hold the two clamp sections together.

A

B

C

D

■ Unscrew the removable conduit connector and any screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief through the hole below the terminal block opening.

Reaching inside the terminal block opening, screw the removable conduit connector onto the strain relief threads.

A

B

A. Strain relief tab pointing up

B. Hole below terminal block opening

C. Clamp section

D. Strain relief tab pointing down

■ Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position.

Do not further tighten strain relief screws at this point.

C

A. Removable conduit connector

B. Hole below terminal block opening

C. Strain relief threads

7

■ Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable.

4-wire connection: Power supply cord

IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.

A

B F

4. Now complete installation following instructions for your type of electrical connection:

4-wire (recommended)

3-wire (if 4-wire is not available)

Electrical Connection Options

If your home has: And you will be connecting to:

Go to Section

4-wire receptacle

(NEMA Type 14-30R)

4-wire connection:

Power supply cord

4-wire direct

A UL listed, 120/

240-volt minimum,

30-amp, dryer power supply cord*

A fused disconnect or circuit breaker box*

4-wire connection:

Direct Wire

5"

(127 mm)

3-wire receptacle

(NEMA type 10-30R)

A UL listed, 120/

240-volt minimum,

30-amp, dryer power supply cord*

3-wire connection:

Power supply cord

3-wire direct A fused disconnect or circuit breaker box*

3-wire connection:

Direct Wire

(89 mm)

*If local codes do not permit the connection of a cabinet-ground conductor to the neutral wire, go to “Optional 3-wire connection” section.

C D E

A. 4-wire receptacle (NEMA type 14-30R)

B. 4-prong plug

C. Ground prong

D. Neutral prong

E. Spade terminals with upturned ends

F. 3/4" (19 mm) UL listed strain relief

G. Ring terminals

G

1. Remove center terminal block screw.

2. Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord under center terminal block screw. Tighten screw.

A

C

B D

E

A. External ground conductor screw - Dotted line shows position of NEUTRAL ground wire before being moved to center terminal block screw.

B. Center terminal block screw

C. Neutral ground wire

D. Neutral wire (white or center wire)

E. 3/4" (19 mm) UL listed strain relief

8

3. Connect ground wire (green or bare) of power supply cord to external ground conductor screw. Tighten screw.

A

D

When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.

B

E

C

F

A. External ground conductor screw

B. Ground wire (green or bare) of power supply cord

C. 3/4" (19 mm) UL listed strain relief

D. Center terminal block screw

E. Neutral ground wire

F. Neutral wire (white or center wire)

4. Connect the other wires to outer terminal block screws. Tighten screws.

1. Remove center terminal block screw.

2. Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and place the hooked end

(hook facing right) of the neutral wire (white or center wire) of direct wire cable under the center screw of the terminal block. Squeeze hooked ends together. Tighten screw.

A

C

B D

E

5. Tighten strain relief screws.

6. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

7. You have completed your electrical connection. Now go to

“Venting Requirements.”

4-wire connection: Direct wire

IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.

Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.

Strip 5" (127 mm) of outer covering from end of cable, leaving bare ground wire at 5" (127 mm). Cut 1 1 /

2

" (38 mm) from 3 remaining wires. Strip insulation back 1" (25 mm). Shape ends of wires into a hook shape.

1"

(25 mm)

A. External ground conductor screw - Dotted line shows position of NEUTRAL ground wire before being moved to center terminal block screw.

B. Center terminal block screw

C. Neutral ground wire

D. Neutral wire (white or center wire)

E. 3/4" (19 mm) UL listed strain relief

3. Connect ground wire (green or bare) of direct wire cable to external ground conductor screw. Tighten screw.

A

D

B

C

E

F

5"

(127 mm)

A. External ground conductor screw

B. Ground wire (green or bare) of power supply cable

C. 3/4" (19 mm) UL listed strain relief

D. Center terminal block screw

E. Neutral ground wire

F. Neutral wire (white or center wire)

4. Place the hooked ends of the other direct wire cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.

9

5. Tighten strain relief screw.

6. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

7. You have completed your electrical connection. Now go to

“Venting Requirements.”

3-wire connection: Power supply cord

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

A

B D E

3-wire connection: Direct wire

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.

Strip 3 1 /

2

" (89 mm) of outer covering from end of cable. Strip insulation back 1" (25 mm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape ends of wires into a hook shape.

1"

(25 mm)

C G F

A. 3-wire receptacle (NEMA type 10-30R)

B. 3-wire plug

C. Neutral prong

D. Spade terminals with upturned ends

E. 3/4" (19 mm) UL listed strain relief

F. Ring terminals

G. Neutral (white or center wire)

1. Loosen or remove center terminal block screw.

2. Connect neutral wire (white or center wire) of power supply cord to the center terminal screw of the terminal block. Tighten screw.

C

A

B

D

3½"

(89 mm)

When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.

1. Loosen or remove center terminal block screw.

2. Place the hooked end of the neutral wire (white or center wire) of direct wire cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw.

C

A

E

B

D

A. External ground conductor screw

B. Neutral ground wire

C. Center terminal block screw

D. Neutral wire (white or center wire)

E. 3/4" (19 mm) UL listed strain relief

3. Connect the other wires to outer terminal block screws. Tighten screws.

E

4. Tighten strain relief screws.

5. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

6. You have completed your electrical connection. Now go to

“Venting Requirements.”

A. External ground conductor screw

B. Neutral ground wire

C. Center terminal block screw

D. Neutral wire (white or center wire)

E. 3/4" (19 mm) UL listed strain relief

3. Place the hooked ends of the other direct wire cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.

10

4. Tighten strain relief screw.

5. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

6. You have completed your electrical connection. Now go to

“Venting Requirements.”

Optional 3-wire connection

Use for direct wire or power supply cord where local codes do not permit connecting cabinet-ground conductor to neutral wire.

1. Remove center terminal block screw.

2. Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord/cable under center terminal block screw. Tighten screw.

B

A

C

D

E

F

A. External ground conductor screw

B. Center terminal block screw

C. Neutral ground wire

D. Neutral wire (white or center wire)

E. 3/4" (19 mm) UL listed strain relief

F. Grounding path determined by a qualified electrician

3. Connect the other wires to outer terminal block screws. Tighten screws.

VENTING

Venting Requirements

WARNING:

To reduce the risk of fire, this dryer MUST BE

EXHAUSTED OUTDOORS.

IMPORTANT: Observe all governing codes and ordinances.

The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building.

If using an existing vent system

Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint.

Replace any plastic or metal foil vent with rigid heavy metal vent or flexible metal vent.

Review vent system chart. Modify existing vent system if necessary to achieve the best drying performance. Only rigid or flexible metal vent shall be used for exhausting.

If this is a new vent system

Vent material

■ Use a heavy metal vent. Do not use plastic or metal foil vent.

■ 4" (102 mm) heavy metal exhaust vent and clamps must be used.

4. Tighten strain relief screws.

5. Connect a separate copper ground wire from the external ground conductor screw to an adequate ground.

4" (102 mm) heavy metal exhaust vent

Vent products can be purchased from your dealer or by calling

Whirlpool Service. For more information, see the “Assistance or

Service” section.

Rigid metal vent

■ For best drying performance, rigid metal vents are recommended.

■ Rigid metal vent is recommended to avoid crushing and kinking.

11

Flexible metal vent

■ Flexible metal vents are acceptable only if accessible for cleaning.

■ Flexible metal vent must be fully extended and supported when the dryer is in its final location.

Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance.

Do not install flexible metal vent in enclosed walls, ceilings, or floors.

The total length of flexible metal vent should not exceed

7¾ ft. (2.4 m).

Elbows

45° elbows provide better airflow than 90° elbows.

■ Do not use an exhaust hood with a magnetic latch.

Plan Vent System

Choose your exhaust installation type

Recommended exhaust installations

Typical installations vent the dryer from the rear of the dryer. Other installations are possible.

B

C

Good Better

Clamps

■ Use clamps to seal all joints.

■ Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the duct and catch lint. Do not use duct tape.

A

F

G

D

E

Clamp

Exhaust

A and B: Recommended hood styles.

C: Acceptable hood style.

B

4"

(102 mm)

A

2½"

(64 mm)

4"

(102 mm)

4"

(102 mm)

A. Louvered hood style

B. Box hood style

C. Angled hood style

An exhaust hood should cap the vent to keep rodents and insects from entering the home.

Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks, or bushes, snow line, etc.).

A. Dryer

B. Elbow

C. Wall

D. Exhaust hood

H

E. Clamps

F. Rigid metal or flexible metal vent

G. Vent length necessary to connect elbows

H. Exhaust outlet

Optional exhaust installations

This dryer can be converted to exhaust out the right side, left side, or through the bottom. If you prefer, you may contact your local dealer to have the dryer converted.

WARNING

Fire Hazard

Cover unused exhaust holes with the following kit:

W10470674 (midnight grey)

Contact your local dealer.

Failure to follow these instructions can result in death, fire, electrical shock, or serious injury.

12

A B

A. Standard rear offset exhaust installation

B. Left or right side exhaust installation

C. Bottom exhaust installation

C

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for your installation. Two examples of close-clearance installations are shown. Refer to the manufacturer’s instructions.

A B

A. Over-the-top installation (also available with one offset elbow)

B. Periscope installation

NOTE: The following kits for close-clearance alternate installations are available for purchase. Please see the “Assistance or Service” section to order.

■ Over-the-Top Installation:

Part Number 4396028

Periscope Installation (For use with dryer vent to wall vent mismatch):

Part Number 4396037 - 0" (0 mm) to 18" (457 mm) mismatch

Part Number 4396011 - 18" (457 mm) to 29" (737 mm) mismatch

Part Number 4396014 - 29" (737 mm) to 50" (1.27 m) mismatch

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

Plan the installation to use the fewest number of elbows and turns.

When using elbows or making turns, allow as much room as possible.

Bend vent gradually to avoid kinking.

Use the fewest 90° turns possible.

Determine vent length and elbows needed for best drying performance

■ Use the following vent system chart to determine type of vent material and hood combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified in the

Vent system chart.

Exhaust systems longer than those specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and increased energy usage.

The vent system chart provides venting requirements that will help to achieve the best drying performance.

Vent system chart

NOTE: Side and bottom exhaust installations have a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.

Number 90º elbows

Type of vent Box /louvered hoods

Angled hoods

0

1

2

3

4

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

64ft (20 m) 58ft (17.7 m)

54 ft (16.5 m) 48 ft (14.6 m)

44 ft (13.4 m) 38 ft (11.6 m)

35 ft (10.7 m) 29 ft (8.8 m)

27 ft (8.2 m) 21 ft (6.4 m)

Install Vent System

1. Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood.

2. Connect vent to exhaust hood. Vent must fit inside exhaust hood.

Secure vent to exhaust hood with 4" (102 mm) clamp.

3. Run vent to dryer location. Use the straightest path possible.

See “Determine vent path” in “Plan Vent System.” Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape, screws, or other fastening devices that extend into the interior of the vent to secure the vent, because they can catch lint.

INSTALL LEVELING LEGS

Determine vent path

■ Select the route that will provide the straightest and most direct path outdoors.

1. To avoid damaging the floor, use a large flat piece of cardboard from the dryer carton. Place cardboard under the entire back edge of the dryer.

13

2. Firmly grasp the body of the dryer (not the console panel). Gently lay the dryer on the cardboard. See illustration.

4. Using pliers, tighten the couplings with an additional two-thirds turn.

3. Examine the leveling legs. Find the diamond marking.

NOTE: Do not overtighten. Damage to the coupling can result.

5. Attach “Y” connector to brass male end of small hose. Screw on coupling by hand until it is seated on connector.

6. One end of the long hose has a wire mesh strainer inside the coupling. Attach this end to the “Y” connector.

7. Attach washer cold inlet hose to other end of “Y” connector.

Screw on coupling by hand until it is seated on connector.

A

4. Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the diamond marking is no longer visible.

5. Place a carton corner post from dryer packaging under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent.

CONNECT VENT

1. Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure the vent is clean.

The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood. Check that the vent is secured to exhaust hood with a 4" (102 mm) clamp.

2. Move dryer into its final location. Do not crush or kink vent.

3. Once the exhaust vent connection is made, remove the corner posts and cardboard.

CONNECT INLET HOSE

(STEAM MODELS)

The dryer must be connected to the cold water faucet using the new inlet hoses. Do not use old hoses.

1. Turn cold water faucet off and remove washer inlet hose.

2. Remove old rubber washer from inlet hose and replace with new rubber washer provided. If space permits, attach the brass female end of the “Y” connector to the cold water faucet.

NOTE: If “Y” connector can be attached directly to cold water faucet, go to Step 6. If “Y” connector cannot be attached directly to the cold water faucet, the short hose must be used.

Continue with Step 3.

3. Attach short hose to cold water faucet. Screw on coupling by hand until it is seated on faucet.

A. Inlet to cold water

8. Using pliers, tighten the couplings an additional two-thirds turn.

NOTE: Do not overtighten. Damage to the coupling can result.

9. Attach other end of long hose to fill valve at bottom of dryer back panel. Screw on coupling by hand until it is seated on fill valve connector.

10. Using pliers, tighten the coupling an additional two-thirds turn.

NOTE: Do not overtighten. Damage to the coupling can result.

11. Check that the water faucets are on.

12. Check for leaks around “Y” connector, faucet, and hoses.

14

LEVEL DRYER

Check the levelness of the dryer. Check levelness first side to side, then front to back.

If the dryer is not level, prop up the dryer using a wood block. Use a wrench to adjust the legs up or down and check again for levelness.

COMPLETE INSTALLATION

1. Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.

2. Check that you have all of your tools.

3. Dispose of/recycle all packaging materials.

4. Check the dryer’s final location. Be sure the vent is not crushed or kinked.

5. Check that the dryer is level. See “Level Dryer.”

6. Remove the film on the console and any tape remaining on the dryer.

7. Wipe the dryer drum interior thoroughly with a damp cloth to remove any dust.

8. Read “Dryer Use.”

9. For power supply cord installation, plug into a grounded outlet.

For direct wire installation, turn on power.

Steam Models Only:

10. Be sure the water faucets are on.

11. Check for leaks around “Y” connector, faucet, and hoses.

12. If you live in a hard water area, use of a water softener is recommended to control the buildup of scale through the water system in the dryer. Over time, the buildup of lime scale may clog different parts of the water system, which will reduce product performance. Excessive scale buildup may lead to the need for certain part replacement or repair.

All Models:

13. Select a Timed Dry heated cycle, and start the dryer. Do not select the Air Only Temperature setting.

If the dryer will not start, check the following:

Controls are set in a running or “On” position.

Start button has been pushed firmly.

Dryer is plugged into a grounded 3 prong outlet and/or electrical supply is connected.

Household fuse is intact and tight, or circuit breaker has not tripped.

■ Dryer door is closed.

This dryer automatically runs an installation diagnostic routine at the start of its first cycle.

If you receive an L2 code, there may be a problem with your home power supply keeping the dryer’s heater from turning on.

See “Troubleshooting.”

14. When the dryer has been running for 5 minutes, open the dryer door and feel for heat. If you feel heat, cancel cycle and close the door.

If you do not feel heat, turn off the dryer and check the following:

■ There may be 2 household fuses or circuit breakers for the dryer. Check that both fuses are intact and tight, or that both circuit breakers have not tripped. If there is still no heat, contact a qualified technician.

NOTE: You may notice an odor when the dryer is first heated.

This odor is common when the heating element is first used.

The odor will go away.

TROUBLESHOOTING

First try the solutions suggested here and possibly avoid the cost of a service call...

Dryer Operation

Dryer will not run

Has a household fuse blown, or has a circuit breaker tripped?

There may be 2 household fuses or circuit breakers for the dryer.

Check that both fuses are intact and tight, or that both circuit breakers have not tripped. Replace the fuse or reset the circuit breaker. If the problem continues, call an electrician.

Is the correct power supply available?

Electric dryers require 240-volt power supply. Check with a qualified electrician.

Was a regular fuse used?

Use a time-delay fuse.

No heat

■ Has a household fuse blown, or has a circuit breaker tripped?

The drum may be turning, but you may not have heat. Electric dryers use 2 household fuses or circuit breakers. Replace the fuse or reset the circuit breaker. If the problem continues, call an electrician.

Dryer displaying code message

“PF” (power failure), check the following:

Was the drying cycle interrupted by a power failure?

Press and hold START to restart the dryer.

“L2” Diagnostic Code (low or no line voltage condition):

The drum will turn, but there may be a problem with your home power supply keeping the dryer's heater from turning on. The dryer will continue to run when this diagnostic code is present.

Press any key to clear the code from the display and return to the estimated time remaining.

15

Try the following:

Check to see if a household fuse has blown or circuit breaker has tripped. Electric dryers use two household fuses or breakers. Replace the fuse or reset the circuit breaker.

Confirm the power cord is properly installed. Refer to “Electrical

Connection” for details.

Select a Timed Dry heated cycle, and restart the dryer.

If the message persists, consult a qualified electrician.

“AF” (low airflow condition):

The dryer will continue to run when this diagnostic code is present. Press any key to clear the code from the display and return to the estimated time remaining.

Try the following:

Clean lint screen.

Check to see if the vent run from the dryer to the wall is crushed or kinked.

Confirm the vent run from the dryer to the wall is free of lint and debris.

Confirm the exterior vent exhaust hood is free of lint and debris.

Confirm your vent system falls within the recommended run length and number of elbows for the type of vent you are using. Refer to “Plan Vent System” for details.

■ Select a Timed Dry heated cycle, and restart the dryer.

If the message persists, have your entire home venting run cleaned.

“E” Variable (E1, E2, E3) service codes:

Call for service.

Dryer Results

Clothes are not drying satisfactorily, drying times are too long, or load is too hot

Is the lint screen clogged with lint?

Lint screen should be cleaned before each load.

Is the exhaust vent or outside exhaust hood clogged with

lint, restricting air movement?

Run the dryer for 5-10 minutes. Hold your hand under the outside exhaust hood to check air movement. If you do not feel air movement, clean exhaust system of lint or replace exhaust vent with heavy metal or flexible metal vent. See the Installation

Instructions.

Are fabric softener sheets blocking the grille?

Use only one fabric softener sheet, and use it only once.

Is the exhaust vent the correct length?

Check that the exhaust vent is not too long or has too many turns. Long venting will increase drying times. See the

Installation Instructions.

Is the exhaust vent diameter the correct size?

Use 4" (102 mm) diameter vent material.

W10471644B

W10471646B - SP

© 2012 Whirlpool Corporation.

All rights reserved.

Is the dryer located in a room with temperature below

45ºF (7ºC)?

Proper operation of dryer cycles requires temperatures above

45ºF (7ºC).

Is the dryer located in a closet?

Closet doors must have ventilation openings at the top and bottom of the door. The front of the dryer requires a minimum of

1" (25 mm) of airspace, and, for most installations, the rear of the dryer requires 5" (127 mm). See the Installation Instructions.

01/12

Printed in U.S.A.

advertisement

Related manuals

Frequently Answers and Questions

What tools are needed for installation?
Flat-blade screwdriver, #2 Phillips screwdriver, Adjustable wrench, Level, Wire stripper, Vent clamps, Caulk gun and compound, Tin snips, 1/4" nut driver, Tape measure, Pliers.
What parts are included with the dryer?
Leveling legs (4), "Y" connector, Short inlet hose, Long inlet hose, Rubber washer.
What are the minimum installation clearances?
5" (127 mm) behind the dryer for the exhaust vent
Can the dryer be installed in a garage?
Yes, but it must be placed at least 18" (460 mm) above the floor.
Can the dryer be installed in a closet?
Yes, but specific spacing requirements must be met.
What is the recommended installation spacing for a cabinet installation?
1" (25 mm) on the sides, top, and back of the dryer.
What is the recommended installation spacing for a stacked installation?
1" (25 mm) between the dryer and washer, and 5" (127 mm) at the rear of the washer.