Owner's manual | Atlas CP700 Owner`s manual
Add to my manuals16 Pages
Atlas CP700 is a commercial power amplifier designed for demanding contractor applications and engineered to provide years of faithful service. Its independent power supplies ensure maximum channel separation and ultra low distortion figures. It has dual-speed, high efficiency fan cooling, stepped attenuators for security, and loop through feature for input. It's suitable for distributed paging/BGM systems, foreground music systems, night clubs, theaters, and portable sound systems.
advertisement
CP400 & CP700
Commercial Power Amplifier
Owner’s Manual
CP400 & CP700
Commercial Power Amplifiers
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
LIMIT
CH-2
SIGNAL CP700
Commercial Power Amplifier
POWER
CP700
Commercial
Power
Amplifier
CH-1
8, 4, and 2 Ohms
D I R . O U T P U T
+ -
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
+
BRIDGE
MONO
CH-2
8, 4, and 2 Ohms
D I R . O U T P U T
+ -
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
-
BRIDGE
MONO
AUDIO TRANSFORMER
0 70 100
CH-1
I S O L . O U T P U T
-
70V
+ -
25V
+
- 100V +
AUDIO TRANSFORMER
0 70 100
CH-2
I S O L . O U T P U T
+ -
70V 25V
- 100V +
+
POWER
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
MADE IN CHINA
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
AtlasSound.com
IN IN
AMPLIFIER INPUTS
CH-2
+ GND -
CH-1
+
GND
THRU
2
26
22
18 16 14 1
2 1
0 8
LEVEL
2
26
22
18 16 14 1
2 1
0 8
THRU
LEVEL
PARALLEL
STEREO
BRIDGE
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 1 –
Specifications are subject to change without notice.
CP400 & CP700
Commercial Power Amplifier
Owner’s Manual
TABLE OF CONTENTS
Introduction ..........................................................................................................3
Features ...............................................................................................................3
Applications ..........................................................................................................3
Front Panel Description ........................................................................................4
Rear Panel Description .........................................................................................5
Input Wiring ..........................................................................................................7
Speaker Output Wiring .........................................................................................9
Specifications .......................................................................................................15
Warranty ...............................................................................................................16
SAFETy INSTruCTIONS
Please Read Carefully Before Installing or Operating This Product
• Read instructions fully.
• Pay attention to any and all warnings.
• Connect this amplifier only to the correct operating voltage.
• Do not attempt to service this unit. Only a qualified service technician should open this unit for
servicing.
• Warning: To reduce the risk of fire or electric shock, do not expose this appliance to rain or
moisture.
HEArINg DAmAgE!
All professional loudspeaker systems are easily capable of producing very high sound pressure levels. Use care with the operation of this amplifier and wear the appropriate hearing protection.
Exposure to excessive sound pressure levels can cause permanent hearing damage.
SHOCk HAzArD!
The Atlas Sound CP400 and CP700, when in operation, can produce a shock hazard at the speaker terminals. Make sure the amplifier is turned off when installing or removing connections at the speaker terminal barrier strip. After connecting the proper speaker load, rEPLACE the terminal strip cover!
VENTILATION
Although the CP400 and CP700 are internally fan cooled and have thermal protection circuitry, adequate ventilation is required to ensure trouble-free operation. When rack mounting one or more of the Atlas Sound CP Series power amplifiers, install an exhaust fan in the rack to evacuate heat buildup. Consult Atlas Sound’s Technical Support at 1-800-876-3333 for advice on thermal management and assistance with rack selection for this product.
rACk mOuNTINg
Although the internal output transformers are mounted close to the front panel, when rack mounting the CP400 and CP700, be sure the unit has adequate front and rear support.
AtlasSound.com
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 2 –
Specifications are subject to change without notice.
CP400 & CP700
Commercial Power Amplifier
Owner’s Manual
INTrODuCTION
Congratulations and thank you for purchasing the Atlas Sound CP400/CP700 dual channel power amplifier. This product is a professional grade audio power amplifier specifically designed for demanding contractor applications and engineered to provide years of faithful service. Two independent channels driven by separate power supplies ensure maximum channel separation and ultra low distortion figures. Whether your application is a large distributed constant voltage sound system or a high SPL sound reinforcement system, the Atlas Sound Series is the answer for high power/low cost amplification needs.
FEATurES
• Independent power supplies
• Soft clip limiter protection
• Dual-speed, high efficiency fan cooling
• Stepped attenuators mounted on the rear for security
• Stereo, bridge, or parallel operating modes selectable via rear mounted switch
• Balanced inputs on barrier strip and XLR connectors
• Loop through feature on male XLRs, one per channel input
• Short-circuit, temperature, and DC offset protection
• 25V, 70.7V, 100V, and direct coupled (2,4, and 8 Ω) outputs mounted on barrier strips with covers
for safety
• Toroidal output transformers provide extended high frequency response and effectively lower the
electrical interference
• Power-up muting
APPLICATIONS
The Atlas CP400/CP700 are the perfect choice for distributed paging/BGM systems, foreground music systems, and distributed sound masking applications. They are also at home in night clubs, theaters, portable sound systems, and anywhere clean high-fidelity audio amplification is needed.
AtlasSound.com
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 3 –
Specifications are subject to change without notice.
CP400 & CP700
Commercial Power Amplifier
Owner’s Manual
FrONT PANEL DESCrIPTION
2
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
LIMIT
CH-2
SIGNAL CP700
Commercial Power Amplifier
POWER
1
3
4
Figure 1
1. Power Switch
This rocker switch supplies power to the amplifier. A red LED located above the power
CH-1
8, 4, and 2 Ohms
D I R . O U T P U T
+ -
AUDIO TRANSFORMER
0 70 100
CH-1
I S O L . O U T P U T
AMPLIFIER INPUTS
Power
Amplifier
CH-2 CH-1
+
BRIDGE
MONO
CH-2
8, 4, and 2 Ohms
D I R . O U T P U T
+ -
-
BRIDGE
MONO
70V
- 100V +
+ GND + Per Channel
Output Power 2. Protect LED Indicators
-
70V
+ -
25V
+
The amplifier features several types of protection circuitry to prevent damage during
AC230V-50/60Hz
AC240V-50/60Hz
- 100V +
AUDIO TRANSFORMER
0 70 100
CH-2
I S O L . O U T P U T
2
26
22
18 16 14 1
2 1
0 8
2
26
22
18 16 14 1
2 1
0 8
+ +
power-up or fault conditions. If any of these LEDs illuminate, one of the various protection
GND LEVEL LEVEL features is safeguarding the amplifier. The output relays will disconnect the speaker loads when
CAUTION BRIDGE
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
MADE IN CHINA
CAUTION
RISK OF ELECTRIC SHOCK the protection circuitry detects a fault condition.
NE PAS OUVRIR
PARALLEL
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
• Loudspeaker Protection - When power is first applied, the speaker protection relay is
open, preventing transients from reaching the loudspeakers. After the internal power
supplies have stabilized, the relay will close, connecting the amplifier output to the load.
The yellow Protect LEDs will illuminate during this power-up process.
• Thermal Protection - The amplifier protection circuitry monitors itself for excessive
internal operating temperatures. In the event this circuitry detects abnormal thermal
conditions (blocked cooling fan or high ambient temperatures), the speaker relay
will disconnect the speaker load from the amplifier. Once the internal operating
temperature drops back to a safe level, the relay will close, reconnecting the speaker load
to the amplifier.
• Short Circuit Protection - The yellow Protect LEDs will illuminate should the amplifier
detect a short circuit on the attached speaker load or if the load impedance is too low.
When this condition is detected, the internal speaker relays will open up, disconnecting
the load from the amplifier. The protection circuitry will stay activated until the fault is
cleared.
Note: Once the specific fault has been corrected, the power may have to be cycled to reset the
protection circuitry.
3. Signal “Status” LED Indicator
The green “Status” LEDs will illuminate once the input signal has reached -26 dBV or higher.
AtlasSound.com
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 4 –
Specifications are subject to change without notice.
CP400 & CP700
Commercial Power Amplifier
Owner’s Manual
4. Limit LED Indicator
The CP400 and CP700 come equipped with limiter circuitry and LEDs to indicate when this
circuitry is activated. The limiter circuitry engages only when the input signals reach a specific,
SIGNAL
CH-2
SIGNAL CP700
Commercial Power Amplifier
enough to prevent clipping at the speaker output terminals.
POWER
rEAr PANEL DESCrIPTION
6
IN
GND
THRU
2
26
22
18 16 14 1
2 1
0 8
LEVEL
AMPLIFIER INPUTS
CH-2
+ GND -
CH-1
+
IN
2
26
22
18 16 14 1
2 1
0 8
THRU
LEVEL
PARALLEL
STEREO
BRIDGE
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
8
10
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
CH-1
8, 4, and 2 Ohms
D I R . O U T P U T
+ -
+
BRIDGE
MONO
CH-2
8, 4, and 2 Ohms
D I R . O U T P U T
+ -
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
-
BRIDGE
MONO
AUDIO TRANSFORMER
0
-
70V
+
70 100
-
25V
+
CH-1
I S O L . O U T P U T
- 100V +
AUDIO TRANSFORMER
0 70 100
CH-2
I S O L . O U T P U T
+ -
70V 25V
- 100V +
+
POWER
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
MADE IN CHINA
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
7
5
5. gain Controls
11
9
Figure 2
One stepped attenuator per channel increases or decreases the sensitivity by 2 dB per step.
Maximum voltage gain is 32 dB.
6. CH1/CH2 Inputs (XLr Connectors)
Two female XLR inputs (one per channel) are provided. These inputs are balanced and
configured as follows: pin 1 ground, pin 2 +, pin 3 -. The XLR connections are typically used in
portable audio systems where quick connect and disconnect is warranted.
7. Balanced Barrier Strip Inputs
Balanced inputs are provided on this barrier strip for permanent installation applications. The
use of the appropriate spade type lug is highly recommended for best connection integrity and a
neat, professional appearance.
8. CH1/CH2 Loop Through
Two male XLR (one per channel) are provided for looping the input signals to other devices.
These connectors are wired in parallel with the female XLR inputs, pin for pin.
AtlasSound.com
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 5 –
Specifications are subject to change without notice.
CP400 & CP700
Commercial Power Amplifier
Owner’s Manual
9. Stereo/Parallel/Bridge Switch
This 3 position switch changes the operating mode of the amplifier. DO NOT move this switch when the amplifier is powered up and connected to a load.
• Stereo - When the switch is set to this position, the amplifier operates as two independent
amplifiers. Use this position for stereo program material or for two discreet paging/sound
masking zones.
• Parallel - When the switch is set to this position a single mono input signal is to be used.
Connect the input wiring to either channel 1 Or channel 2. The one input signal will drive both amp channels. Use this position when two speaker zones are being fed by a mono signal. (See note below)
• Bridge - When the switch is set to this position, connect the mono input signal to channel
1 ONLy. The speaker load is connected across the two positive terminals as shown in
Figure 7 on page 10. The amplifier will deliver approximately twice the voltage across the
load. Please observe the minimum load specification when operating in Bridge mode.
Note: A 6 dB loss of output power will occur when operating in parallel mode. To over come this loss, connect the positive terminal on input 1 to the positive terminal on input 2 and connect the negative terminal on input 1 to the negative terminal on input 2. Short lengths of
22-gauge wire can be used.
10. CH1/CH2, Low Impedance Speaker Outputs
The amplifier direct speaker outputs bypass the internal constant voltage transformers and are used for direct connection to loudspeakers. The amplifier will operate into 2, 4, and 8 Ω loads
The use of appropriately sized spade lugs is recommended for speaker wire termination; connect the speaker line common to the “-” terminal and the positive lead to the “+” terminal.
For high power applications, use the proper gauge wire for the speaker connections. Contact
Atlas Sound Tech Support (1-800-876-3333) for assistance in determining the proper size wire.
11. CH1/CH2, 25/70.7/100V Speaker Outputs
The amplifier will drive constant voltage speaker loads for use in commercial business music/ paging systems and sound masking systems. The use of spade lugs for terminating and connecting the speaker home runs is recommended. The speaker line common connects to the
“0” terminal and the positive lead connects to the desired voltage for required system requires for proper operation (Figures 8,9,10; Pages 11-12).
Calculating Constant Voltage Loads
To calculate the maximum quantity of transformer coupled loudspeakers you can safely connect to the amplifier, first add up the total number of speakers that will be connected to one channel of the amplifier, then multiply that total speaker number by the tap setting you plan to use. The result will be the load in watts that the amp output channel will see. It is good engineering practice to leave a 20% margin below the maximum rated output power of the amplifier. In this case, one channel of the amplifier can supply 350 W of power at
70.7V. Derate this by 20%, leaving 280 W of power available for constant voltage speakers.
AtlasSound.com
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 6 –
Specifications are subject to change without notice.
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
LIMIT
CH-2
SIGNAL
CP700
Commercial
Power
Amplifier
CH-1
8, 4, and 2 Ohms AUDIO TRANSFORMER
D I R . O U T P U T
+ 0 70 100
CH-1
I S O L . O U T P U T
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
CH-2
+
BRIDGE
MONO
D I R . O U T P U T
+ -
-
0
70V
+ -
25V
- 100V +
+
8, 4, and 2 Ohms AUDIO TRANSFORMER
70 100
CH-2
I S O L . O U T P U T
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
-
BRIDGE
MONO
-
70V
+ -
25V
- 100V +
+
POWER
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
MADE IN CHINA
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CP700
Commercial Power Amplifier
Owner’s Manual
INPuT WIrINg
Balanced Inputs
Balanced input wiring requires two conductors with shield (22-gauge is the most common). The use of crimp type spade lugs is highly recommended for permanent installations. At the input section located on the rear of the amplifier, wire the “hot”/positive lead to the “+” terminal, the
“common”/negative lead to the “-” terminal and the shield/drain to the “ground” terminal (Figure 3).
The XLR inputs (+4 dB balanced line level) can be utilized with standard 3-pin XLR male to female patch cables to accommodate outputs from a mixer, equalizer, or crossover when the amplifier is used as a portable sound system amplifier.
White (+)
Black (-)
Shield
White (+)
Black (-)
Shield
GND
IN
THRU
6
3
2
26
22
-00
18 16 14 1
2 1
LEVEL
0 8
AMPLIFIER INPUTS
CH-2
+ GND -
CH-1
+
PARALLEL
6
3
2
26
22
18 16 14 1
-00
LEVEL
STEREO
2 1
0 8
IN
THRU
BRIDGE
Figure 3
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
AtlasSound.com
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 7 –
Specifications are subject to change without notice.
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
LIMIT
CH-2
SIGNAL
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
CH-1
8, 4, and 2 Ohms AUDIO TRANSFORMER
D I R . O U T P U T
+ 0 70 100
CH-1
I S O L . O U T P U T
CH-2
+
BRIDGE
MONO
D I R . O U T P U T
+ -
-
0
70V
+ -
25V
- 100V +
+
8, 4, and 2 Ohms AUDIO TRANSFORMER
70 100
CH-2
I S O L . O U T P U T
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
-
BRIDGE
MONO
-
70V
+ -
25V
- 100V +
+
POWER
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
MADE IN CHINA
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CP700
Commercial Power Amplifier
POWER
CP400 & CP700
Commercial Power Amplifier
Owner’s Manual unbalanced Input
Unbalanced wiring typically is found on consumer equipment (CD players, DVD players, etc.) and is generally a compromise of noise rejection and cable lengths. A single conductor and an overall shield are most common, as in the standard cables supplied with consumer equipment. Keep unbalanced wire lengths within 10' between equipment, wire the hot lead to the “+” terminal, and the shield to the ground terminal. Install a jumper wire between the “-” terminal and the ground – a loss of gain will result without this jumper (Figure 4).
GND
IN
THRU
6
White/Red (+)
Shield
3
2
26
22
18 16 14 1
-00
LEVEL
2 1
0 8
White/Red (+)
Shield
AMPLIFIER INPUTS
CH-2
+ GND -
CH-1
+
6
3
2
26
22
-00
18 16 14 1
2 1
0 8
LEVEL
IN
THRU
Jumper
PARALLEL
STEREO
BRIDGE
Figure 4
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
AtlasSound.com
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 8 –
Specifications are subject to change without notice.
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
LIMIT
CH-2
SIGNAL CP700 PROTECT
Commercial Power Amplifier
LIMIT LIMIT
SIGNAL
CH-1 CH-2
SIGNAL
POWER
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
LIMIT
CH-2
SIGNAL
CP700
Commercial
Power
Amplifier
CH-1
8, 4, and 2 Ohms AUDIO TRANSFORMER
D I R . O U T P U T
+ 0 70 100
CH-1
I S O L . O U T P U T
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
CH-2
+
+ +
BRIDGE
MONO
70V 25V
- 100V +
8, 4, and 2 Ohms AUDIO TRANSFORMER
D I R . O U T P U T
+ 0 70 100
CH-2
I S O L . O U T P U T
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
-
BRIDGE
MONO
-
70V
+ -
25V
- 100V +
+
POWER
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
MADE IN CHINA
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CP400 & CP700
Commercial Power Amplifier
Owner’s Manual
SPEAkEr OuTPuT WIrINg
CP700
CP700
IN IN
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
CH-1
8, 4, and 2 Ohms
D I R . O U T P U T
+ -
AUDIO TRANSFORMER
0 70 100
CH-1
I S O L . O U T P U T Low Impedance Direct Coupled Output (Stereo)
CH-2
D I R . O U T P U T
+
For direct coupled operation into 2, 4, and 8
+ -
AMPLIFIER INPUTS
Ω loads, connect the loudspeaker leads to the barrier
GND +
+
BRIDGE
MONO
PROTECT common lead to the “-” terminal. The use of heavy gauge wiring is recommended to avoid voltage
0
70V 25V
- 100V +
LIMIT
70 100
CH-2
I S O L . O U T P U T
POWER
CAUTION
-
BRIDGE
MONO
(1-800-876-3333) for suggestions on cable capacities. Be sure you know the quantity of speakers and cable lengths before calling (Figure 5).
-
70V
+ -
25V
+
3
2
26
22
18 16 14 1
2 1
Commercial Power Amplifier 0 8
POWER
3
2
26
22
18 16 14 1
CH-1
8, 4, and 2 Ohms
D I R . O U T P U T
+ -
- 100V +
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
MADE IN CHINA
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
Commercial Power Amplifier
AUDIO TRANSFORMER
0 70 100
CH-1
I S O L . O U T P U T
CP700
Commercial
Power
Amplifier
To direct coupled loudspeakers
400 W / 4 Ohms
350 W / 70.7 V
To direct coupled
AC230V-50/60Hz
AC240V-50/60Hz
CH-1
8, 4, and 2 Ohms
D I R . O U T P U T
CH-2
POWER
D I R . O U T P U T
CAUTION
8, 4, and 2 Ohms
+
+
BRIDGE
MONO
+
-
BRIDGE
MONO
-
-
GND
0
-00
LEVEL
AUDIO TRANSFORMER
70 100
CH-1
I S O L . O U T P U T
- 100V +
AUDIO TRANSFORMER
0 70 100
I S O L . O U T P U T
-
-
70V
70V
+
+ -
-
25V
25V
+
+
CH-2
Figure 5
CAUTION
PARALLEL
RISK OF ELECTRIC SHOCK
CH-1
Observe the speaker connection information in the preceeding paragraph (Stereo Direct Coupled
Output). With the amplifier turned OFF, move the rear mounted selector switch to the “Parallel”
-00
LEVEL
STEREO
2 1
0 8
THRU
BRIDGE
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
Switch set to “Stereo”
+
BRIDGE
MONO
CH-2
8, 4, and 2 Ohms
D I R . O U T P U T
+ -
+ -
25V
- 100V +
AUDIO TRANSFORMER
0 70 100
CH-2
I S O L . O U T P U T
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR position and connect your mono input wiring to either the channel one or channel two inputs. Both channels will be driven from this mono signal (Figure 6).
THRU
-
BRIDGE
MONO
-
70V
+ -
25V
- 100V +
+ White
Black
Shield
GND
3
2
26
22
18 16 14 1
2 1
0 8
-00
LEVEL
3
2
26
22
18 16 14 1
-00
LEVEL
2 1
0 8
IN
THRU
POWER MADE IN CHINA
STEREO
CAUTION
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
IN IN
PARALLEL BRIDGE
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
AMPLIFIER INPUTS
CH-2 CH-1
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
+ GND +
Optional Jumpers
See Note on Page 6
THRU
3
2
26
22
18 16 14 1
2 1
0 8
3
2
26
22
18 16 14 1
2 1
0 8
THRU
Switch set to “Parallel”
GND
-00
LEVEL
-00
LEVEL Figure 6
PARALLEL
STEREO
BRIDGE
1601 Jack McKay Blvd., Ennis, TX 75119
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
AtlasSound.com – 9 –
Specifications are subject to change without notice.
CP700
Commercial Power Amplifier
POWER
IN IN
AMPLIFIER INPUTS
CH-2
+ GND -
CH-1
+
GND
THRU
6
3
2
26
22
18 16 14 1
2 1
0 8
-00
LEVEL
6
3
2
26
22
18 16 14 1
2 1
0 8
-00
LEVEL
THRU
PARALLEL
STEREO
BRIDGE
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
LIMIT
CH-2
SIGNAL
PROTECT
LIMIT
PROTECT
LIMIT
SIGNAL CP700 SIGNAL
POWER
CP400 & CP700
Commercial Power Amplifier
Owner’s Manual
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
CH-1
8, 4, and 2 Ohms
D I R . O U T P U T
+ -
+
BRIDGE
MONO
CH-2
8, 4, and 2 Ohms
D I R . O U T P U T
+ -
Bridge mono Configuration (Direct Coupled)
If higher power levels are required, the Atlas amplifier can be used in Bridge Mono mode, which utilizes both channels of the amp across the speaker load.
IN IN
AUDIO TRANSFORMER
0 70 100
CH-1
With the amplifier turned OFF, move the rear mounted selector switch to the “Bridge” position and connect the input signal to channel one. Connect your speaker load (4 and 8 Ω only) across the “+” terminals of both channels, with channel 1 being positive and channel 2 being negative (Figure 7).
-
70V
+ -
25V
+
- 100V +
AUDIO TRANSFORMER
0 70 100
CH-2 any Bridge mode application!
+ GND -
CAuTION: A high voltage potential exists across the two “+” speaker terminals when operating in
AC100V-50/60Hz
AC120V-50/60Hz
THRU
3
2
26
22
18 16 14 1
2 1
0 8
THRU
AC230V-50/60Hz
AC240V-50/60Hz
POWER
CAUTION
-
BRIDGE
MONO
-
70V
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
+ -
25V
+
3
2
26
22
18 16 14 1
2 1
0 8
- 100V +
MADE IN CHINA
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CP700
Commercial
Power
Amplifier
CH-1
8, 4, and 2 Ohms
D I R . O U T P U T
+ -
AUDIO TRANSFORMER -00
0 70 100
CH-1
I S O L . O U T P U T
PARALLEL
-00
LEVEL
STEREO
BRIDGE
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
+
BRIDGE
MONO
CH-2
8, 4, and 2 Ohms
D I R . O U T P U T
+ -
-
70V
+ -
25V
+
- 100V +
AUDIO TRANSFORMER
0 70 100
CH-2
I S O L . O U T P U T
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
To loudspeakers,
4 Ω minimum
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
POWER
-
BRIDGE
MONO
-
70V
+ -
25V
- 100V +
+
MADE IN CHINA
Switch set to “Bridge”
Figure 7
CAUTION
CAUTION
25V, 70.7V, and 100V Transformer Output Wiring
RISK OF ELECTRIC SHOCK
DO NOT OPEN
For transformer coupled operation into high impedance loads, connect your loudspeaker leads follows:
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR to the barrier strip connections labeled “Audio Transformer.” Connect the speaker home runs as
• 25V - Connect the positive speaker lead to the terminal labeled “100” and the negative
speaker lead to the terminal labeled “70” (Figure 8).
• 70.7V - Connect the positive speaker lead to the terminal labeled “70” and the negative
speaker lead to the terminal labeled “0” (Figure 9).
• 100V - Connect the positive speaker lead to the terminal labeled “100” and the negative
speaker lead to the terminal labeled “0” (Figure 10).
Note: Refer to page 6 of this manual to the paragraph entitled “Calculating Constant Voltage
Loads” to determine how many transformer coupled loudspeakers you can drive with the Atlas amplifier.
AtlasSound.com
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 10 –
Specifications are subject to change without notice.
CP700
Commercial Power Amplifier
POWER
IN IN
AMPLIFIER INPUTS
CH-2
+ GND -
CH-1
+
GND
THRU
6
2
3
26
22
18 16 14 1
2 1
0 8
-00
LEVEL
6
2
3
26
22
18 16 14 1
2 1
0 8
-00
LEVEL
THRU
PARALLEL
STEREO
BRIDGE
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
LIMIT
CH-2
SIGNAL CP700
Commercial Power Amplifier
POWER
PROTECT
CP400 & CP700
Commercial Power Amplifier
PROTECT
LIMIT
Owner’s Manual
SIGNAL
CH-1 CH-2
SIGNAL
CH-1
8, 4, and 2 Ohms AUDIO TRANSFORMER
D I R . O U T P U T
+ 0 70 100
CH-1
I S O L . O U T P U T
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
To 25V speaker load
CH-2
+
BRIDGE
MONO
D I R . O U T P U T
+ -
-
0
70V
+ -
25V
- 100V +
+
8, 4, and 2 Ohms AUDIO TRANSFORMER
70 100
CH-2
I S O L . O U T P U T
25V
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
-
BRIDGE
MONO
-
70V
+ -
25V
- 100V +
+
POWER
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
To 25V speaker load
MADE IN CHINA
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
Figure 8
CP700
Commercial
Power
Amplifier
CH-1
8, 4, and 2 Ohms AUDIO TRANSFORMER
D I R . O U T P U T
+ 0 70 100
CH-1
I S O L . O U T P U T
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
To 70.7V speaker load
CH-2
+
BRIDGE
MONO
D I R . O U T P U T
+ -
-
0
70V
+ -
25V
- 100V +
+
8, 4, and 2 Ohms AUDIO TRANSFORMER
70 100
CH-2
I S O L . O U T P U T
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
-
BRIDGE
MONO
-
70V
+ -
25V
- 100V +
+
POWER
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
To 70.7V speaker load
70.7V
MADE IN CHINA
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
Figure 9
AtlasSound.com
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 11 –
Specifications are subject to change without notice.
CP700
IN
POWER
Commercial Power Amplifier
AMPLIFIER INPUTS
CH-2
+ GND -
CH-1
+
IN
GND
THRU
6
2
3
26
22
18 16 14 1
2 1
0 8
-00
LEVEL
IN
6
2
3
26
22
18 16 14 1
2 1
0 8
-00
LEVEL
THRU
PARALLEL
STEREO
BRIDGE
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
IN
AMPLIFIER INPUTS
CH-2
+ GND -
CH-1
+
GND
THRU
6
2
3
26
22
18 16 14 1
2 1
0 8
-00
LEVEL
6
2
3
26
22
18 16 14 1
2 1
0 8
-00
LEVEL
THRU
PARALLEL
STEREO
BRIDGE
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
LIMIT
CH-2
SIGNAL
CP400 & CP700
Commercial Power Amplifier
Owner’s Manual
CP700
Commercial
Power
Amplifier
CH-1
8, 4, and 2 Ohms AUDIO TRANSFORMER
D I R . O U T P U T
+ 0 70 100
CH-1
I S O L . O U T P U T
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
To 100V speaker load
CH-2
+
BRIDGE
MONO
D I R . O U T P U T
+ -
-
0
70V
+ -
25V
- 100V +
+
8, 4, and 2 Ohms AUDIO TRANSFORMER
70 100
CH-2
I S O L . O U T P U T
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
-
BRIDGE
MONO
+ -
70V 25V
- 100V +
+
POWER
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
To 100V speaker load
100V
MADE IN CHINA
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
Figure 10
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CP700
Commercial Power Amplifier
POWER
IN IN
AMPLIFIER INPUTS
CH-2
+ GND -
CH-1
+
GND
THRU
6
2
3
26
22
18 16 14 1
2 1
0 8
-00
LEVEL
6
2
3
26
22
18 16 14 1
2 1
0 8
-00
LEVEL
THRU
PARALLEL
STEREO
BRIDGE
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
AtlasSound.com
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 12 –
Specifications are subject to change without notice.
PROTECT
LIMIT
CP400 & CP700
Commercial Power Amplifier
PROTECT
LIMIT
CH-2
SIGNAL
Owner’s Manual
Bridge mono Transformer Coupled Output Wiring for 140V/200V Output Operation
The amplifier can be configured to drive 140V and 200V speaker lines.
Please observe all necessary safety precautions as the potential for electric shock at the speaker terminals is present.
With the amplifier turned OFF, move the rear mounted selector switch to the “Bridge” position and connect the input signal to channel 1. Connect your speaker load across the “+” terminals of both output terminals as follows:
• 140V Operation - Connect the positive lead of the speaker load to the channel 1 70V
positive “+” terminal, the negative speaker lead connects to the channel 2 70V positive
“+” terminal. Connect a suitable jumper wire between the two terminals labeled “0”.
Consult your local codes to determine if Class I wiring is required (Figure 11).
• 200V Operation - Connect the positive lead of the speaker load to the channel 1 100V
positive “+” terminal, the negative speaker lead connects to the channel 2 100V positive
“+” terminal. Connect a suitable jumper wire between the two terminals labeled “0”.
Consult your local codes to determine if Class I wiring is required (Figure 12).
CAuTION: A high voltage potential exists across the two “+” speaker terminals when operating in any Bridge mode application!
CP700
Commercial
Power
Amplifier
CH-1
8, 4, and 2 Ohms AUDIO TRANSFORMER
D I R . O U T P U T
+ 0 70 100
CH-1
I S O L . O U T P U T
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
To 140V speaker load
CH-2
+
BRIDGE
MONO
D I R . O U T P U T
+ -
-
0
70V
+ -
25V
- 100V +
+
8, 4, and 2 Ohms AUDIO TRANSFORMER
70 100
CH-2
I S O L . O U T P U T
Note Jumper
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
POWER
-
BRIDGE
MONO
+ -
70V 25V
- 100V +
+
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
MADE IN CHINA
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
Figure 11
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
AtlasSound.com
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 13 –
Specifications are subject to change without notice.
CP700
Commercial Power Amplifier
POWER
IN IN
AMPLIFIER INPUTS
CH-2
+ GND -
CH-1
+
GND
THRU
6
2
3
26
22
18 16 14 1
2 1
0 8
-00
LEVEL
6
2
3
26
22
18 16 14 1
2 1
0 8
-00
LEVEL
THRU
PARALLEL
STEREO
BRIDGE
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
LIMIT
CH-2
SIGNAL
CP400 & CP700
Commercial Power Amplifier
Owner’s Manual
CP700
Commercial
Power
Amplifier
CH-1
8, 4, and 2 Ohms AUDIO TRANSFORMER
D I R . O U T P U T
+ 0 70 100
CH-1
I S O L . O U T P U T
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
To 200V speaker load
CH-2
+
BRIDGE
MONO
D I R . O U T P U T
+ -
-
0
70V
+ -
25V
- 100V +
+
8, 4, and 2 Ohms AUDIO TRANSFORMER
70 100
CH-2
I S O L . O U T P U T
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
-
BRIDGE
MONO
-
70V
+ -
25V
- 100V +
+
POWER
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
MADE IN CHINA
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
Note Jumper
Figure 12
CP700
Commercial Power Amplifier
POWER
IN IN
AMPLIFIER INPUTS
CH-2
+ GND -
CH-1
+
GND
THRU
6
2
3
26
22
18 16 14 1
2 1
0 8
-00
LEVEL
6
2
3
26
22
18 16 14 1
2 1
0 8
-00
LEVEL
THRU
PARALLEL
STEREO
BRIDGE
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
AtlasSound.com
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 14 –
Specifications are subject to change without notice.
CP400 & CP700
Commercial Power Amplifier
Owner’s Manual
SPECIFICATIONS
DIrECT POWEr OuT
Max Average Power @ 35 Hz-20 kHz with 0.1% THD (10-80K Filter)
CP400
8 Ω, 1 kHz, 0.1% THD 160 W X 2
4 Ω, 1 kHz, 0.1% THD 240 W X 2
2 Ω, 1 kHz, 0.1% THD 270 W X 2
Bridged Mono 8 Ω 500 W
1 kHz, 1% THD
Bridged Mono 4 Ω 600 W
1 kHz, 1% THD
TrANSFOrmEr OuTPuTS
25V
70V
100V
140V Bridged
200V Bridged
FrEquENCy rESPONSE
Direct Outputs (±3 dB)
Transformer Outputs (±3 dB)
175 W X 2
200 W X 2
200 W X 2
400 W
400 W
30 Hz-50 kHz
30 Hz-16 kHz
CP700
240 W X 2
400 W X 2
550 W X 2
850 W
1100 W
280 W X 2
350 W X 2
350 W X 2
700 W
700 W
THD+N
8 Ω, 1 kHz, 240 W per channel
SENSITIVITy
Rated Output into 8 Ω
VOLTAgE gAIN
<.05%
1.25V
32 dB
INPuT ImPEDANCE
Balanced/Unbalanced 20 k/10 k Ω
PrOTECTION CIrCuITS
Output Offset Voltage Protection
Heat Sink Overheat Protection
Transformer Overheat Protection
Load Shorting Protection
Power On/Off Protection
Soft Clip Limiters
CONTrOLS
Power Switch, Ch 1/Ch 2 gain (41 step)
Parallel/Stereo/Bridge Switch
COOLINg
Dual Speed Fan, Temperature Controlled
INDICATOrS
Power, Protect, Signal, Limit
DImENSIONS
5.19" X 18.9" X 16.85" (132 mm X 480 mm X 428 mm)
NET WEIgHT
CP400
44.5 lbs (20.2 kg)
CP700
54 lbs (24.3 kg)
SHIPPINg WEIgHT
CP400
47 lbs (23 kg)
CP700
57 lbs (26 kg)
DAmPINg FACTOr
8 Ω Output, 10 V rms
S/N rATIO
8 Ω per Channel @240 W
>200 dB
>100 dB
AtlasSound.com
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 15 –
Specifications are subject to change without notice.
CP400 & CP700
Commercial Power Amplifier
Limited Warranty
Owner’s Manual
All products manufactured by Atlas Sound are warranted to the original dealer/installer, industrial or commercial purchaser to be free from defects in material and workmanship and to be in compliance with our published specifications, if any. This warranty shall extend from the date of purchase for a period of three years on all Atlas Sound products, including SOUNDOLIER brand, and
ATLAS SOUND brand products except as follows: one year on electronics and control systems; one year on replacement parts; and one year on Musician Series stands and related accessories. Additionally, fuses and lamps carry no warranty. Atlas Sound will solely at its discretion, replace at no charge or repair free of charge defective parts or products when the product has been applied and used in accordance with our published operation and installation instructions. We will not be responsible for defects caused by improper storage, misuse (including failure to provide reasonable and necessary maintenance), accident, abnormal atmospheres, water immersion, lightning discharge, or malfunctions when products have been modified or operated in excess of rated power, altered, serviced or installed in other than a workman like manner. The original sales invoice should be retained as evidence of purchase under the terms of this warranty. All warranty returns must comply with our returns policy set forth below. When products returned to Atlas Sound do not qualify for repair or replacement under our warranty, repairs may be performed at prevailing costs for material and labor unless there is included with the returned product(s) a written request for an estimate of repair costs before any non-warranty work is performed. In the event of replacement or upon completion of repairs, return shipment will be made with the transportation charges collect.
EXCEPT TO THE EXTENT THAT APPLICABLE LAW PREVENTS THE LIMITATION OF CONSEQUENTIAL DAMAGES FOR
PERSONAL INJURY, ATLAS SOUND SHALL NOT BE LIABLE IN TORT OR CONTRACT FOR ANY DIRECT, CONSEQUENTIAL
OR INCIDENTAL LOSS OR DAMAGE ARISING OUT OF THE INSTALLATION, USE OR INABILITY TO USE THE PRODUCTS.
THE ABOVE WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Atlas Sound does not assume, or does it authorize any other person to assume or extend on its behalf, any other warranty, obligation, or liability. This warranty gives you specific legal rights and you may have other rights which vary from state to state.
Service
Should your CP400 or CP700 require service, please contact the
Atlas Sound warranty department at 1-877-689-8055, ext. 277 to obtain an RA number.
Atlas Sound Tech Support can be reached at 1-800-876-3333.
Visit our web site at www.AtlasSound.com to see other Atlas products.
AtlasSound.com
©2010 Atlas Sound L.P. All rights reserved. Atlas Sound and Atlas Power are trademarks of Atlas Sound L.P.
All other trademarks are the property of their respective owners. ATS002102 RevE 08/10
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 16 –
Specifications are subject to change without notice.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project