CP400 & CP700

Commercial Power Amplifier

Owner’s Manual

CP400 & CP700

Commercial Power Amplifiers

PROTECT

LIMIT

SIGNAL

CH-1

PROTECT

LIMIT

CH-2

SIGNAL CP700

Commercial Power Amplifier

POWER

CP700

Commercial

Power

Amplifier

CH-1

8, 4, and 2 Ohms

D I R . O U T P U T

+ -

Per Channel

Output Power

400 W / 4 Ohms

350 W / 70.7 V

+

BRIDGE

MONO

CH-2

8, 4, and 2 Ohms

D I R . O U T P U T

+ -

AC100V-50/60Hz

AC120V-50/60Hz

AC230V-50/60Hz

AC240V-50/60Hz

-

BRIDGE

MONO

AUDIO TRANSFORMER

0 70 100

CH-1

I S O L . O U T P U T

-

70V

+ -

25V

+

- 100V +

AUDIO TRANSFORMER

0 70 100

CH-2

I S O L . O U T P U T

+ -

70V 25V

- 100V +

+

POWER

CAUTION

TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

MADE IN CHINA

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

AVIS RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

AtlasSound.com

IN IN

AMPLIFIER INPUTS

CH-2

+ GND -

CH-1

+

GND

THRU

2

26

22

18 16 14 1

2 1

0 8

LEVEL

2

26

22

18 16 14 1

2 1

0 8

THRU

LEVEL

PARALLEL

STEREO

BRIDGE

1601 Jack McKay Blvd., Ennis, TX 75119

(800) 876-3333 AtlasSound.com

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

– 1 –

Specifications are subject to change without notice.

CP400 & CP700

Commercial Power Amplifier

Owner’s Manual

TABLE OF CONTENTS

Introduction ..........................................................................................................3

Features ...............................................................................................................3

Applications ..........................................................................................................3

Front Panel Description ........................................................................................4

Rear Panel Description .........................................................................................5

Input Wiring ..........................................................................................................7

Speaker Output Wiring .........................................................................................9

Specifications .......................................................................................................15

Warranty ...............................................................................................................16

SAFETy INSTruCTIONS

Please Read Carefully Before Installing or Operating This Product

• Read instructions fully.

• Pay attention to any and all warnings.

• Connect this amplifier only to the correct operating voltage.

• Do not attempt to service this unit. Only a qualified service technician should open this unit for

servicing.

• Warning: To reduce the risk of fire or electric shock, do not expose this appliance to rain or

moisture.

HEArINg DAmAgE!

All professional loudspeaker systems are easily capable of producing very high sound pressure levels. Use care with the operation of this amplifier and wear the appropriate hearing protection.

Exposure to excessive sound pressure levels can cause permanent hearing damage.

SHOCk HAzArD!

The Atlas Sound CP400 and CP700, when in operation, can produce a shock hazard at the speaker terminals. Make sure the amplifier is turned off when installing or removing connections at the speaker terminal barrier strip. After connecting the proper speaker load, rEPLACE the terminal strip cover!

VENTILATION

Although the CP400 and CP700 are internally fan cooled and have thermal protection circuitry, adequate ventilation is required to ensure trouble-free operation. When rack mounting one or more of the Atlas Sound CP Series power amplifiers, install an exhaust fan in the rack to evacuate heat buildup. Consult Atlas Sound’s Technical Support at 1-800-876-3333 for advice on thermal management and assistance with rack selection for this product.

rACk mOuNTINg

Although the internal output transformers are mounted close to the front panel, when rack mounting the CP400 and CP700, be sure the unit has adequate front and rear support.

AtlasSound.com

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

– 2 –

Specifications are subject to change without notice.

CP400 & CP700

Commercial Power Amplifier

Owner’s Manual

INTrODuCTION

Congratulations and thank you for purchasing the Atlas Sound CP400/CP700 dual channel power amplifier. This product is a professional grade audio power amplifier specifically designed for demanding contractor applications and engineered to provide years of faithful service. Two independent channels driven by separate power supplies ensure maximum channel separation and ultra low distortion figures. Whether your application is a large distributed constant voltage sound system or a high SPL sound reinforcement system, the Atlas Sound Series is the answer for high power/low cost amplification needs.

FEATurES

• Independent power supplies

• Soft clip limiter protection

• Dual-speed, high efficiency fan cooling

• Stepped attenuators mounted on the rear for security

• Stereo, bridge, or parallel operating modes selectable via rear mounted switch

• Balanced inputs on barrier strip and XLR connectors

• Loop through feature on male XLRs, one per channel input

• Short-circuit, temperature, and DC offset protection

• 25V, 70.7V, 100V, and direct coupled (2,4, and 8 Ω) outputs mounted on barrier strips with covers

for safety

• Toroidal output transformers provide extended high frequency response and effectively lower the

electrical interference

• Power-up muting

APPLICATIONS

The Atlas CP400/CP700 are the perfect choice for distributed paging/BGM systems, foreground music systems, and distributed sound masking applications. They are also at home in night clubs, theaters, portable sound systems, and anywhere clean high-fidelity audio amplification is needed.

AtlasSound.com

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

– 3 –

Specifications are subject to change without notice.

CP400 & CP700

Commercial Power Amplifier

Owner’s Manual

FrONT PANEL DESCrIPTION

2

PROTECT

LIMIT

SIGNAL

CH-1

PROTECT

LIMIT

CH-2

SIGNAL CP700

Commercial Power Amplifier

POWER

1

3

4

Figure 1

1. Power Switch

This rocker switch supplies power to the amplifier. A red LED located above the power

CH-1

8, 4, and 2 Ohms

D I R . O U T P U T

+ -

AUDIO TRANSFORMER

0 70 100

CH-1

I S O L . O U T P U T

AMPLIFIER INPUTS

Power

Amplifier

CH-2 CH-1

+

BRIDGE

MONO

CH-2

8, 4, and 2 Ohms

D I R . O U T P U T

+ -

-

BRIDGE

MONO

70V

- 100V +

+ GND + Per Channel

Output Power 2. Protect LED Indicators

-

70V

+ -

25V

+

The amplifier features several types of protection circuitry to prevent damage during

AC230V-50/60Hz

AC240V-50/60Hz

- 100V +

AUDIO TRANSFORMER

0 70 100

CH-2

I S O L . O U T P U T

2

26

22

18 16 14 1

2 1

0 8

2

26

22

18 16 14 1

2 1

0 8

+ +

power-up or fault conditions. If any of these LEDs illuminate, one of the various protection

GND LEVEL LEVEL features is safeguarding the amplifier. The output relays will disconnect the speaker loads when

CAUTION BRIDGE

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

MADE IN CHINA

CAUTION

RISK OF ELECTRIC SHOCK the protection circuitry detects a fault condition.

NE PAS OUVRIR

PARALLEL

1601 Jack McKay Blvd., Ennis, TX 75119

(800) 876-3333 AtlasSound.com

Loudspeaker Protection - When power is first applied, the speaker protection relay is

open, preventing transients from reaching the loudspeakers. After the internal power

supplies have stabilized, the relay will close, connecting the amplifier output to the load.

The yellow Protect LEDs will illuminate during this power-up process.

Thermal Protection - The amplifier protection circuitry monitors itself for excessive

internal operating temperatures. In the event this circuitry detects abnormal thermal

conditions (blocked cooling fan or high ambient temperatures), the speaker relay

will disconnect the speaker load from the amplifier. Once the internal operating

temperature drops back to a safe level, the relay will close, reconnecting the speaker load

to the amplifier.

Short Circuit Protection - The yellow Protect LEDs will illuminate should the amplifier

detect a short circuit on the attached speaker load or if the load impedance is too low.

When this condition is detected, the internal speaker relays will open up, disconnecting

the load from the amplifier. The protection circuitry will stay activated until the fault is

cleared.

Note: Once the specific fault has been corrected, the power may have to be cycled to reset the

protection circuitry.

3. Signal “Status” LED Indicator

The green “Status” LEDs will illuminate once the input signal has reached -26 dBV or higher.

AtlasSound.com

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

– 4 –

Specifications are subject to change without notice.

CP400 & CP700

Commercial Power Amplifier

Owner’s Manual

4. Limit LED Indicator

The CP400 and CP700 come equipped with limiter circuitry and LEDs to indicate when this

circuitry is activated. The limiter circuitry engages only when the input signals reach a specific,

SIGNAL

CH-2

SIGNAL CP700

Commercial Power Amplifier

enough to prevent clipping at the speaker output terminals.

POWER

rEAr PANEL DESCrIPTION

6

IN

GND

THRU

2

26

22

18 16 14 1

2 1

0 8

LEVEL

AMPLIFIER INPUTS

CH-2

+ GND -

CH-1

+

IN

2

26

22

18 16 14 1

2 1

0 8

THRU

LEVEL

PARALLEL

STEREO

BRIDGE

1601 Jack McKay Blvd., Ennis, TX 75119

(800) 876-3333 AtlasSound.com

8

10

CP700

Commercial

Power

Amplifier

Per Channel

Output Power

400 W / 4 Ohms

350 W / 70.7 V

CH-1

8, 4, and 2 Ohms

D I R . O U T P U T

+ -

+

BRIDGE

MONO

CH-2

8, 4, and 2 Ohms

D I R . O U T P U T

+ -

AC100V-50/60Hz

AC120V-50/60Hz

AC230V-50/60Hz

AC240V-50/60Hz

-

BRIDGE

MONO

AUDIO TRANSFORMER

0

-

70V

+

70 100

-

25V

+

CH-1

I S O L . O U T P U T

- 100V +

AUDIO TRANSFORMER

0 70 100

CH-2

I S O L . O U T P U T

+ -

70V 25V

- 100V +

+

POWER

CAUTION

TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

MADE IN CHINA

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

AVIS RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

7

5

5. gain Controls

11

9

Figure 2

One stepped attenuator per channel increases or decreases the sensitivity by 2 dB per step.

Maximum voltage gain is 32 dB.

6. CH1/CH2 Inputs (XLr Connectors)

Two female XLR inputs (one per channel) are provided. These inputs are balanced and

configured as follows: pin 1 ground, pin 2 +, pin 3 -. The XLR connections are typically used in

portable audio systems where quick connect and disconnect is warranted.

7. Balanced Barrier Strip Inputs

Balanced inputs are provided on this barrier strip for permanent installation applications. The

use of the appropriate spade type lug is highly recommended for best connection integrity and a

neat, professional appearance.

8. CH1/CH2 Loop Through

Two male XLR (one per channel) are provided for looping the input signals to other devices.

These connectors are wired in parallel with the female XLR inputs, pin for pin.

AtlasSound.com

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

– 5 –

Specifications are subject to change without notice.

CP400 & CP700

Commercial Power Amplifier

Owner’s Manual

9. Stereo/Parallel/Bridge Switch

This 3 position switch changes the operating mode of the amplifier. DO NOT move this switch when the amplifier is powered up and connected to a load.

Stereo - When the switch is set to this position, the amplifier operates as two independent

amplifiers. Use this position for stereo program material or for two discreet paging/sound

masking zones.

Parallel - When the switch is set to this position a single mono input signal is to be used.

Connect the input wiring to either channel 1 Or channel 2. The one input signal will drive both amp channels. Use this position when two speaker zones are being fed by a mono signal. (See note below)

Bridge - When the switch is set to this position, connect the mono input signal to channel

1 ONLy. The speaker load is connected across the two positive terminals as shown in

Figure 7 on page 10. The amplifier will deliver approximately twice the voltage across the

load. Please observe the minimum load specification when operating in Bridge mode.

Note: A 6 dB loss of output power will occur when operating in parallel mode. To over come this loss, connect the positive terminal on input 1 to the positive terminal on input 2 and connect the negative terminal on input 1 to the negative terminal on input 2. Short lengths of

22-gauge wire can be used.

10. CH1/CH2, Low Impedance Speaker Outputs

The amplifier direct speaker outputs bypass the internal constant voltage transformers and are used for direct connection to loudspeakers. The amplifier will operate into 2, 4, and 8 Ω loads

The use of appropriately sized spade lugs is recommended for speaker wire termination; connect the speaker line common to the “-” terminal and the positive lead to the “+” terminal.

For high power applications, use the proper gauge wire for the speaker connections. Contact

Atlas Sound Tech Support (1-800-876-3333) for assistance in determining the proper size wire.

11. CH1/CH2, 25/70.7/100V Speaker Outputs

The amplifier will drive constant voltage speaker loads for use in commercial business music/ paging systems and sound masking systems. The use of spade lugs for terminating and connecting the speaker home runs is recommended. The speaker line common connects to the

“0” terminal and the positive lead connects to the desired voltage for required system requires for proper operation (Figures 8,9,10; Pages 11-12).

Calculating Constant Voltage Loads

To calculate the maximum quantity of transformer coupled loudspeakers you can safely connect to the amplifier, first add up the total number of speakers that will be connected to one channel of the amplifier, then multiply that total speaker number by the tap setting you plan to use. The result will be the load in watts that the amp output channel will see. It is good engineering practice to leave a 20% margin below the maximum rated output power of the amplifier. In this case, one channel of the amplifier can supply 350 W of power at

70.7V. Derate this by 20%, leaving 280 W of power available for constant voltage speakers.

AtlasSound.com

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

– 6 –

Specifications are subject to change without notice.

PROTECT

LIMIT

SIGNAL

CH-1

PROTECT

LIMIT

CH-2

SIGNAL

CP700

Commercial

Power

Amplifier

CH-1

8, 4, and 2 Ohms AUDIO TRANSFORMER

D I R . O U T P U T

+ 0 70 100

CH-1

I S O L . O U T P U T

Per Channel

Output Power

400 W / 4 Ohms

350 W / 70.7 V

CH-2

+

BRIDGE

MONO

D I R . O U T P U T

+ -

-

0

70V

+ -

25V

- 100V +

+

8, 4, and 2 Ohms AUDIO TRANSFORMER

70 100

CH-2

I S O L . O U T P U T

AC100V-50/60Hz

AC120V-50/60Hz

AC230V-50/60Hz

AC240V-50/60Hz

-

BRIDGE

MONO

-

70V

+ -

25V

- 100V +

+

POWER

CAUTION

TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

MADE IN CHINA

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

AVIS RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

CP700

Commercial Power Amplifier

Owner’s Manual

INPuT WIrINg

Balanced Inputs

Balanced input wiring requires two conductors with shield (22-gauge is the most common). The use of crimp type spade lugs is highly recommended for permanent installations. At the input section located on the rear of the amplifier, wire the “hot”/positive lead to the “+” terminal, the

“common”/negative lead to the “-” terminal and the shield/drain to the “ground” terminal (Figure 3).

The XLR inputs (+4 dB balanced line level) can be utilized with standard 3-pin XLR male to female patch cables to accommodate outputs from a mixer, equalizer, or crossover when the amplifier is used as a portable sound system amplifier.

White (+)

Black (-)

Shield

White (+)

Black (-)

Shield

GND

IN

THRU

6

3

2

26

22

-00

18 16 14 1

2 1

LEVEL

0 8

AMPLIFIER INPUTS

CH-2

+ GND -

CH-1

+

PARALLEL

6

3

2

26

22

18 16 14 1

-00

LEVEL

STEREO

2 1

0 8

IN

THRU

BRIDGE

Figure 3

1601 Jack McKay Blvd., Ennis, TX 75119

(800) 876-3333 AtlasSound.com

AtlasSound.com

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

– 7 –

Specifications are subject to change without notice.

PROTECT

LIMIT

SIGNAL

CH-1

PROTECT

LIMIT

CH-2

SIGNAL

CP700

Commercial

Power

Amplifier

Per Channel

Output Power

400 W / 4 Ohms

350 W / 70.7 V

CH-1

8, 4, and 2 Ohms AUDIO TRANSFORMER

D I R . O U T P U T

+ 0 70 100

CH-1

I S O L . O U T P U T

CH-2

+

BRIDGE

MONO

D I R . O U T P U T

+ -

-

0

70V

+ -

25V

- 100V +

+

8, 4, and 2 Ohms AUDIO TRANSFORMER

70 100

CH-2

I S O L . O U T P U T

AC100V-50/60Hz

AC120V-50/60Hz

AC230V-50/60Hz

AC240V-50/60Hz

-

BRIDGE

MONO

-

70V

+ -

25V

- 100V +

+

POWER

CAUTION

TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

MADE IN CHINA

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

AVIS RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

CP700

Commercial Power Amplifier

POWER

CP400 & CP700

Commercial Power Amplifier

Owner’s Manual unbalanced Input

Unbalanced wiring typically is found on consumer equipment (CD players, DVD players, etc.) and is generally a compromise of noise rejection and cable lengths. A single conductor and an overall shield are most common, as in the standard cables supplied with consumer equipment. Keep unbalanced wire lengths within 10' between equipment, wire the hot lead to the “+” terminal, and the shield to the ground terminal. Install a jumper wire between the “-” terminal and the ground – a loss of gain will result without this jumper (Figure 4).

GND

IN

THRU

6

White/Red (+)

Shield

3

2

26

22

18 16 14 1

-00

LEVEL

2 1

0 8

White/Red (+)

Shield

AMPLIFIER INPUTS

CH-2

+ GND -

CH-1

+

6

3

2

26

22

-00

18 16 14 1

2 1

0 8

LEVEL

IN

THRU

Jumper

PARALLEL

STEREO

BRIDGE

Figure 4

1601 Jack McKay Blvd., Ennis, TX 75119

(800) 876-3333 AtlasSound.com

AtlasSound.com

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

– 8 –

Specifications are subject to change without notice.

PROTECT

LIMIT

SIGNAL

CH-1

PROTECT

LIMIT

CH-2

SIGNAL CP700 PROTECT

Commercial Power Amplifier

LIMIT LIMIT

SIGNAL

CH-1 CH-2

SIGNAL

POWER

PROTECT

LIMIT

SIGNAL

CH-1

PROTECT

LIMIT

CH-2

SIGNAL

CP700

Commercial

Power

Amplifier

CH-1

8, 4, and 2 Ohms AUDIO TRANSFORMER

D I R . O U T P U T

+ 0 70 100

CH-1

I S O L . O U T P U T

Per Channel

Output Power

400 W / 4 Ohms

350 W / 70.7 V

CH-2

+

+ +

BRIDGE

MONO

70V 25V

- 100V +

8, 4, and 2 Ohms AUDIO TRANSFORMER

D I R . O U T P U T

+ 0 70 100

CH-2

I S O L . O U T P U T

AC100V-50/60Hz

AC120V-50/60Hz

AC230V-50/60Hz

AC240V-50/60Hz

-

BRIDGE

MONO

-

70V

+ -

25V

- 100V +

+

POWER

CAUTION

TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

MADE IN CHINA

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

AVIS RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

CP400 & CP700

Commercial Power Amplifier

Owner’s Manual

SPEAkEr OuTPuT WIrINg

CP700

CP700

IN IN

CP700

Commercial

Power

Amplifier

Per Channel

Output Power

400 W / 4 Ohms

350 W / 70.7 V

AC100V-50/60Hz

AC120V-50/60Hz

AC230V-50/60Hz

AC240V-50/60Hz

CP700

Commercial

Power

Amplifier

Per Channel

Output Power

400 W / 4 Ohms

350 W / 70.7 V

AC100V-50/60Hz

AC120V-50/60Hz

AC230V-50/60Hz

AC240V-50/60Hz

CH-1

8, 4, and 2 Ohms

D I R . O U T P U T

+ -

AUDIO TRANSFORMER

0 70 100

CH-1

I S O L . O U T P U T Low Impedance Direct Coupled Output (Stereo)

CH-2

D I R . O U T P U T

+

For direct coupled operation into 2, 4, and 8

+ -

AMPLIFIER INPUTS

Ω loads, connect the loudspeaker leads to the barrier

GND +

+

BRIDGE

MONO

PROTECT common lead to the “-” terminal. The use of heavy gauge wiring is recommended to avoid voltage

0

70V 25V

- 100V +

LIMIT

70 100

CH-2

I S O L . O U T P U T

POWER

CAUTION

-

BRIDGE

MONO

(1-800-876-3333) for suggestions on cable capacities. Be sure you know the quantity of speakers and cable lengths before calling (Figure 5).

-

70V

+ -

25V

+

3

2

26

22

18 16 14 1

2 1

Commercial Power Amplifier 0 8

POWER

3

2

26

22

18 16 14 1

CH-1

8, 4, and 2 Ohms

D I R . O U T P U T

+ -

- 100V +

TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

MADE IN CHINA

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

AVIS RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

Commercial Power Amplifier

AUDIO TRANSFORMER

0 70 100

CH-1

I S O L . O U T P U T

CP700

Commercial

Power

Amplifier

To direct coupled loudspeakers

400 W / 4 Ohms

350 W / 70.7 V

To direct coupled

AC230V-50/60Hz

AC240V-50/60Hz

CH-1

8, 4, and 2 Ohms

D I R . O U T P U T

CH-2

POWER

D I R . O U T P U T

CAUTION

8, 4, and 2 Ohms

+

+

BRIDGE

MONO

+

-

BRIDGE

MONO

-

-

GND

0

-00

LEVEL

AUDIO TRANSFORMER

70 100

CH-1

I S O L . O U T P U T

- 100V +

AUDIO TRANSFORMER

0 70 100

I S O L . O U T P U T

-

-

70V

70V

+

+ -

-

25V

25V

+

+

CH-2

Figure 5

CAUTION

PARALLEL

RISK OF ELECTRIC SHOCK

CH-1

Observe the speaker connection information in the preceeding paragraph (Stereo Direct Coupled

Output). With the amplifier turned OFF, move the rear mounted selector switch to the “Parallel”

-00

LEVEL

STEREO

2 1

0 8

THRU

BRIDGE

1601 Jack McKay Blvd., Ennis, TX 75119

(800) 876-3333 AtlasSound.com

Switch set to “Stereo”

+

BRIDGE

MONO

CH-2

8, 4, and 2 Ohms

D I R . O U T P U T

+ -

+ -

25V

- 100V +

AUDIO TRANSFORMER

0 70 100

CH-2

I S O L . O U T P U T

TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

AVIS RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR position and connect your mono input wiring to either the channel one or channel two inputs. Both channels will be driven from this mono signal (Figure 6).

THRU

-

BRIDGE

MONO

-

70V

+ -

25V

- 100V +

+ White

Black

Shield

GND

3

2

26

22

18 16 14 1

2 1

0 8

-00

LEVEL

3

2

26

22

18 16 14 1

-00

LEVEL

2 1

0 8

IN

THRU

POWER MADE IN CHINA

STEREO

CAUTION

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

IN IN

PARALLEL BRIDGE

TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

AVIS RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

AMPLIFIER INPUTS

CH-2 CH-1

1601 Jack McKay Blvd., Ennis, TX 75119

(800) 876-3333 AtlasSound.com

+ GND +

Optional Jumpers

See Note on Page 6

THRU

3

2

26

22

18 16 14 1

2 1

0 8

3

2

26

22

18 16 14 1

2 1

0 8

THRU

Switch set to “Parallel”

GND

-00

LEVEL

-00

LEVEL Figure 6

PARALLEL

STEREO

BRIDGE

1601 Jack McKay Blvd., Ennis, TX 75119

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

AtlasSound.com – 9 –

Specifications are subject to change without notice.

CP700

Commercial Power Amplifier

POWER

IN IN

AMPLIFIER INPUTS

CH-2

+ GND -

CH-1

+

GND

THRU

6

3

2

26

22

18 16 14 1

2 1

0 8

-00

LEVEL

6

3

2

26

22

18 16 14 1

2 1

0 8

-00

LEVEL

THRU

PARALLEL

STEREO

BRIDGE

1601 Jack McKay Blvd., Ennis, TX 75119

(800) 876-3333 AtlasSound.com

PROTECT

LIMIT

SIGNAL

CH-1

PROTECT

LIMIT

CH-2

SIGNAL

PROTECT

LIMIT

PROTECT

LIMIT

SIGNAL CP700 SIGNAL

POWER

CP400 & CP700

Commercial Power Amplifier

Owner’s Manual

CP700

Commercial

Power

Amplifier

Per Channel

Output Power

400 W / 4 Ohms

350 W / 70.7 V

CH-1

8, 4, and 2 Ohms

D I R . O U T P U T

+ -

+

BRIDGE

MONO

CH-2

8, 4, and 2 Ohms

D I R . O U T P U T

+ -

Bridge mono Configuration (Direct Coupled)

If higher power levels are required, the Atlas amplifier can be used in Bridge Mono mode, which utilizes both channels of the amp across the speaker load.

IN IN

AUDIO TRANSFORMER

0 70 100

CH-1

With the amplifier turned OFF, move the rear mounted selector switch to the “Bridge” position and connect the input signal to channel one. Connect your speaker load (4 and 8 Ω only) across the “+” terminals of both channels, with channel 1 being positive and channel 2 being negative (Figure 7).

-

70V

+ -

25V

+

- 100V +

AUDIO TRANSFORMER

0 70 100

CH-2 any Bridge mode application!

+ GND -

CAuTION: A high voltage potential exists across the two “+” speaker terminals when operating in

AC100V-50/60Hz

AC120V-50/60Hz

THRU

3

2

26

22

18 16 14 1

2 1

0 8

THRU

AC230V-50/60Hz

AC240V-50/60Hz

POWER

CAUTION

-

BRIDGE

MONO

-

70V

TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

+ -

25V

+

3

2

26

22

18 16 14 1

2 1

0 8

- 100V +

MADE IN CHINA

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CP700

Commercial

Power

Amplifier

CH-1

8, 4, and 2 Ohms

D I R . O U T P U T

+ -

AUDIO TRANSFORMER -00

0 70 100

CH-1

I S O L . O U T P U T

PARALLEL

-00

LEVEL

STEREO

BRIDGE

AVIS RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

Per Channel

Output Power

400 W / 4 Ohms

350 W / 70.7 V

+

BRIDGE

MONO

CH-2

8, 4, and 2 Ohms

D I R . O U T P U T

+ -

-

70V

+ -

25V

+

- 100V +

AUDIO TRANSFORMER

0 70 100

CH-2

I S O L . O U T P U T

1601 Jack McKay Blvd., Ennis, TX 75119

(800) 876-3333 AtlasSound.com

To loudspeakers,

4 Ω minimum

AC100V-50/60Hz

AC120V-50/60Hz

AC230V-50/60Hz

AC240V-50/60Hz

POWER

-

BRIDGE

MONO

-

70V

+ -

25V

- 100V +

+

MADE IN CHINA

Switch set to “Bridge”

Figure 7

CAUTION

CAUTION

25V, 70.7V, and 100V Transformer Output Wiring

RISK OF ELECTRIC SHOCK

DO NOT OPEN

For transformer coupled operation into high impedance loads, connect your loudspeaker leads follows:

TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

AVIS RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR to the barrier strip connections labeled “Audio Transformer.” Connect the speaker home runs as

25V - Connect the positive speaker lead to the terminal labeled “100” and the negative

speaker lead to the terminal labeled “70” (Figure 8).

70.7V - Connect the positive speaker lead to the terminal labeled “70” and the negative

speaker lead to the terminal labeled “0” (Figure 9).

100V - Connect the positive speaker lead to the terminal labeled “100” and the negative

speaker lead to the terminal labeled “0” (Figure 10).

Note: Refer to page 6 of this manual to the paragraph entitled “Calculating Constant Voltage

Loads” to determine how many transformer coupled loudspeakers you can drive with the Atlas amplifier.

AtlasSound.com

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

– 10 –

Specifications are subject to change without notice.

CP700

Commercial Power Amplifier

POWER

IN IN

AMPLIFIER INPUTS

CH-2

+ GND -

CH-1

+

GND

THRU

6

2

3

26

22

18 16 14 1

2 1

0 8

-00

LEVEL

6

2

3

26

22

18 16 14 1

2 1

0 8

-00

LEVEL

THRU

PARALLEL

STEREO

BRIDGE

1601 Jack McKay Blvd., Ennis, TX 75119

(800) 876-3333 AtlasSound.com

PROTECT

LIMIT

SIGNAL

CH-1

PROTECT

LIMIT

CH-2

SIGNAL CP700

Commercial Power Amplifier

POWER

PROTECT

CP400 & CP700

Commercial Power Amplifier

PROTECT

LIMIT

Owner’s Manual

SIGNAL

CH-1 CH-2

SIGNAL

CH-1

8, 4, and 2 Ohms AUDIO TRANSFORMER

D I R . O U T P U T

+ 0 70 100

CH-1

I S O L . O U T P U T

CP700

Commercial

Power

Amplifier

Per Channel

Output Power

400 W / 4 Ohms

350 W / 70.7 V

To 25V speaker load

CH-2

+

BRIDGE

MONO

D I R . O U T P U T

+ -

-

0

70V

+ -

25V

- 100V +

+

8, 4, and 2 Ohms AUDIO TRANSFORMER

70 100

CH-2

I S O L . O U T P U T

25V

AC100V-50/60Hz

AC120V-50/60Hz

AC230V-50/60Hz

AC240V-50/60Hz

-

BRIDGE

MONO

-

70V

+ -

25V

- 100V +

+

POWER

CAUTION

TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

To 25V speaker load

MADE IN CHINA

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

AVIS RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

Figure 8

CP700

Commercial

Power

Amplifier

CH-1

8, 4, and 2 Ohms AUDIO TRANSFORMER

D I R . O U T P U T

+ 0 70 100

CH-1

I S O L . O U T P U T

Per Channel

Output Power

400 W / 4 Ohms

350 W / 70.7 V

To 70.7V speaker load

CH-2

+

BRIDGE

MONO

D I R . O U T P U T

+ -

-

0

70V

+ -

25V

- 100V +

+

8, 4, and 2 Ohms AUDIO TRANSFORMER

70 100

CH-2

I S O L . O U T P U T

AC100V-50/60Hz

AC120V-50/60Hz

AC230V-50/60Hz

AC240V-50/60Hz

-

BRIDGE

MONO

-

70V

+ -

25V

- 100V +

+

POWER

CAUTION

TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

To 70.7V speaker load

70.7V

MADE IN CHINA

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

AVIS RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

Figure 9

AtlasSound.com

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

– 11 –

Specifications are subject to change without notice.

CP700

IN

POWER

Commercial Power Amplifier

AMPLIFIER INPUTS

CH-2

+ GND -

CH-1

+

IN

GND

THRU

6

2

3

26

22

18 16 14 1

2 1

0 8

-00

LEVEL

IN

6

2

3

26

22

18 16 14 1

2 1

0 8

-00

LEVEL

THRU

PARALLEL

STEREO

BRIDGE

1601 Jack McKay Blvd., Ennis, TX 75119

(800) 876-3333 AtlasSound.com

IN

AMPLIFIER INPUTS

CH-2

+ GND -

CH-1

+

GND

THRU

6

2

3

26

22

18 16 14 1

2 1

0 8

-00

LEVEL

6

2

3

26

22

18 16 14 1

2 1

0 8

-00

LEVEL

THRU

PARALLEL

STEREO

BRIDGE

1601 Jack McKay Blvd., Ennis, TX 75119

(800) 876-3333 AtlasSound.com

PROTECT

LIMIT

SIGNAL

CH-1

PROTECT

LIMIT

CH-2

SIGNAL

CP400 & CP700

Commercial Power Amplifier

Owner’s Manual

CP700

Commercial

Power

Amplifier

CH-1

8, 4, and 2 Ohms AUDIO TRANSFORMER

D I R . O U T P U T

+ 0 70 100

CH-1

I S O L . O U T P U T

Per Channel

Output Power

400 W / 4 Ohms

350 W / 70.7 V

To 100V speaker load

CH-2

+

BRIDGE

MONO

D I R . O U T P U T

+ -

-

0

70V

+ -

25V

- 100V +

+

8, 4, and 2 Ohms AUDIO TRANSFORMER

70 100

CH-2

I S O L . O U T P U T

AC100V-50/60Hz

AC120V-50/60Hz

AC230V-50/60Hz

AC240V-50/60Hz

-

BRIDGE

MONO

+ -

70V 25V

- 100V +

+

POWER

CAUTION

TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

To 100V speaker load

100V

MADE IN CHINA

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

Figure 10

AVIS RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

CP700

Commercial Power Amplifier

POWER

IN IN

AMPLIFIER INPUTS

CH-2

+ GND -

CH-1

+

GND

THRU

6

2

3

26

22

18 16 14 1

2 1

0 8

-00

LEVEL

6

2

3

26

22

18 16 14 1

2 1

0 8

-00

LEVEL

THRU

PARALLEL

STEREO

BRIDGE

1601 Jack McKay Blvd., Ennis, TX 75119

(800) 876-3333 AtlasSound.com

AtlasSound.com

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

– 12 –

Specifications are subject to change without notice.

PROTECT

LIMIT

CP400 & CP700

Commercial Power Amplifier

PROTECT

LIMIT

CH-2

SIGNAL

Owner’s Manual

Bridge mono Transformer Coupled Output Wiring for 140V/200V Output Operation

The amplifier can be configured to drive 140V and 200V speaker lines.

Please observe all necessary safety precautions as the potential for electric shock at the speaker terminals is present.

With the amplifier turned OFF, move the rear mounted selector switch to the “Bridge” position and connect the input signal to channel 1. Connect your speaker load across the “+” terminals of both output terminals as follows:

140V Operation - Connect the positive lead of the speaker load to the channel 1 70V

positive “+” terminal, the negative speaker lead connects to the channel 2 70V positive

“+” terminal. Connect a suitable jumper wire between the two terminals labeled “0”.

Consult your local codes to determine if Class I wiring is required (Figure 11).

200V Operation - Connect the positive lead of the speaker load to the channel 1 100V

positive “+” terminal, the negative speaker lead connects to the channel 2 100V positive

“+” terminal. Connect a suitable jumper wire between the two terminals labeled “0”.

Consult your local codes to determine if Class I wiring is required (Figure 12).

CAuTION: A high voltage potential exists across the two “+” speaker terminals when operating in any Bridge mode application!

CP700

Commercial

Power

Amplifier

CH-1

8, 4, and 2 Ohms AUDIO TRANSFORMER

D I R . O U T P U T

+ 0 70 100

CH-1

I S O L . O U T P U T

Per Channel

Output Power

400 W / 4 Ohms

350 W / 70.7 V

To 140V speaker load

CH-2

+

BRIDGE

MONO

D I R . O U T P U T

+ -

-

0

70V

+ -

25V

- 100V +

+

8, 4, and 2 Ohms AUDIO TRANSFORMER

70 100

CH-2

I S O L . O U T P U T

Note Jumper

AC100V-50/60Hz

AC120V-50/60Hz

AC230V-50/60Hz

AC240V-50/60Hz

POWER

-

BRIDGE

MONO

+ -

70V 25V

- 100V +

+

CAUTION

TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

MADE IN CHINA

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

Figure 11

AVIS RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

AtlasSound.com

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

– 13 –

Specifications are subject to change without notice.

CP700

Commercial Power Amplifier

POWER

IN IN

AMPLIFIER INPUTS

CH-2

+ GND -

CH-1

+

GND

THRU

6

2

3

26

22

18 16 14 1

2 1

0 8

-00

LEVEL

6

2

3

26

22

18 16 14 1

2 1

0 8

-00

LEVEL

THRU

PARALLEL

STEREO

BRIDGE

1601 Jack McKay Blvd., Ennis, TX 75119

(800) 876-3333 AtlasSound.com

PROTECT

LIMIT

SIGNAL

CH-1

PROTECT

LIMIT

CH-2

SIGNAL

CP400 & CP700

Commercial Power Amplifier

Owner’s Manual

CP700

Commercial

Power

Amplifier

CH-1

8, 4, and 2 Ohms AUDIO TRANSFORMER

D I R . O U T P U T

+ 0 70 100

CH-1

I S O L . O U T P U T

Per Channel

Output Power

400 W / 4 Ohms

350 W / 70.7 V

To 200V speaker load

CH-2

+

BRIDGE

MONO

D I R . O U T P U T

+ -

-

0

70V

+ -

25V

- 100V +

+

8, 4, and 2 Ohms AUDIO TRANSFORMER

70 100

CH-2

I S O L . O U T P U T

AC100V-50/60Hz

AC120V-50/60Hz

AC230V-50/60Hz

AC240V-50/60Hz

-

BRIDGE

MONO

-

70V

+ -

25V

- 100V +

+

POWER

CAUTION

TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

MADE IN CHINA

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

AVIS RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

Note Jumper

Figure 12

CP700

Commercial Power Amplifier

POWER

IN IN

AMPLIFIER INPUTS

CH-2

+ GND -

CH-1

+

GND

THRU

6

2

3

26

22

18 16 14 1

2 1

0 8

-00

LEVEL

6

2

3

26

22

18 16 14 1

2 1

0 8

-00

LEVEL

THRU

PARALLEL

STEREO

BRIDGE

1601 Jack McKay Blvd., Ennis, TX 75119

(800) 876-3333 AtlasSound.com

AtlasSound.com

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

– 14 –

Specifications are subject to change without notice.

CP400 & CP700

Commercial Power Amplifier

Owner’s Manual

SPECIFICATIONS

DIrECT POWEr OuT

Max Average Power @ 35 Hz-20 kHz with 0.1% THD (10-80K Filter)

CP400

8 Ω, 1 kHz, 0.1% THD 160 W X 2

4 Ω, 1 kHz, 0.1% THD 240 W X 2

2 Ω, 1 kHz, 0.1% THD 270 W X 2

Bridged Mono 8 Ω 500 W

1 kHz, 1% THD

Bridged Mono 4 Ω 600 W

1 kHz, 1% THD

TrANSFOrmEr OuTPuTS

25V

70V

100V

140V Bridged

200V Bridged

FrEquENCy rESPONSE

Direct Outputs (±3 dB)

Transformer Outputs (±3 dB)

175 W X 2

200 W X 2

200 W X 2

400 W

400 W

30 Hz-50 kHz

30 Hz-16 kHz

CP700

240 W X 2

400 W X 2

550 W X 2

850 W

1100 W

280 W X 2

350 W X 2

350 W X 2

700 W

700 W

THD+N

8 Ω, 1 kHz, 240 W per channel

SENSITIVITy

Rated Output into 8 Ω

VOLTAgE gAIN

<.05%

1.25V

32 dB

INPuT ImPEDANCE

Balanced/Unbalanced 20 k/10 k Ω

PrOTECTION CIrCuITS

Output Offset Voltage Protection

Heat Sink Overheat Protection

Transformer Overheat Protection

Load Shorting Protection

Power On/Off Protection

Soft Clip Limiters

CONTrOLS

Power Switch, Ch 1/Ch 2 gain (41 step)

Parallel/Stereo/Bridge Switch

COOLINg

Dual Speed Fan, Temperature Controlled

INDICATOrS

Power, Protect, Signal, Limit

DImENSIONS

5.19" X 18.9" X 16.85" (132 mm X 480 mm X 428 mm)

NET WEIgHT

CP400

44.5 lbs (20.2 kg)

CP700

54 lbs (24.3 kg)

SHIPPINg WEIgHT

CP400

47 lbs (23 kg)

CP700

57 lbs (26 kg)

DAmPINg FACTOr

8 Ω Output, 10 V rms

S/N rATIO

8 Ω per Channel @240 W

>200 dB

>100 dB

AtlasSound.com

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

– 15 –

Specifications are subject to change without notice.

CP400 & CP700

Commercial Power Amplifier

Limited Warranty

Owner’s Manual

All products manufactured by Atlas Sound are warranted to the original dealer/installer, industrial or commercial purchaser to be free from defects in material and workmanship and to be in compliance with our published specifications, if any. This warranty shall extend from the date of purchase for a period of three years on all Atlas Sound products, including SOUNDOLIER brand, and

ATLAS SOUND brand products except as follows: one year on electronics and control systems; one year on replacement parts; and one year on Musician Series stands and related accessories. Additionally, fuses and lamps carry no warranty. Atlas Sound will solely at its discretion, replace at no charge or repair free of charge defective parts or products when the product has been applied and used in accordance with our published operation and installation instructions. We will not be responsible for defects caused by improper storage, misuse (including failure to provide reasonable and necessary maintenance), accident, abnormal atmospheres, water immersion, lightning discharge, or malfunctions when products have been modified or operated in excess of rated power, altered, serviced or installed in other than a workman like manner. The original sales invoice should be retained as evidence of purchase under the terms of this warranty. All warranty returns must comply with our returns policy set forth below. When products returned to Atlas Sound do not qualify for repair or replacement under our warranty, repairs may be performed at prevailing costs for material and labor unless there is included with the returned product(s) a written request for an estimate of repair costs before any non-warranty work is performed. In the event of replacement or upon completion of repairs, return shipment will be made with the transportation charges collect.

EXCEPT TO THE EXTENT THAT APPLICABLE LAW PREVENTS THE LIMITATION OF CONSEQUENTIAL DAMAGES FOR

PERSONAL INJURY, ATLAS SOUND SHALL NOT BE LIABLE IN TORT OR CONTRACT FOR ANY DIRECT, CONSEQUENTIAL

OR INCIDENTAL LOSS OR DAMAGE ARISING OUT OF THE INSTALLATION, USE OR INABILITY TO USE THE PRODUCTS.

THE ABOVE WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO WARRANTIES OF

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

Atlas Sound does not assume, or does it authorize any other person to assume or extend on its behalf, any other warranty, obligation, or liability. This warranty gives you specific legal rights and you may have other rights which vary from state to state.

Service

Should your CP400 or CP700 require service, please contact the

Atlas Sound warranty department at 1-877-689-8055, ext. 277 to obtain an RA number.

Atlas Sound Tech Support can be reached at 1-800-876-3333.

Visit our web site at www.AtlasSound.com to see other Atlas products.

AtlasSound.com

©2010 Atlas Sound L.P. All rights reserved. Atlas Sound and Atlas Power are trademarks of Atlas Sound L.P.

All other trademarks are the property of their respective owners. ATS002102 RevE 08/10

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

– 16 –

Specifications are subject to change without notice.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement