Continuum V2532W User manual


Add to my manuals
48 Pages

advertisement

Continuum V2532W User manual | Manualzz

A

How to use your New

Continuous Flow

Water Heater

Model V2532W

(Residential outdoor unit)

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

– Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

– WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your building.

• Immediately call your gas supplier from a neighbor's phone.

Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fire department.

– Installation and service must be performed by a qualified installer, service agency or the gas supplier.

www.rinnai.us

A

S P E C I F I C A T I O N S

Type of appliance

Operation

Exhaust system

Temperature controlled continuous flow gas hot water system

With / without remote controls, mounted in kitchen, bathroom, etc.

Direct Vent - Forced combustion

Rinnai model number

Maximum/Minimum gas rate (Input BTU's)

Thermal Efficiency

REU-V2532W-US

199,000 BTU's - 15,000 BTU's Natural Gas

199,000 BTU's - 15,000 BTU's Propane Gas

Natural Gas: 84% Propane: 85%

Energy Factor (EF) Natural Gas: 0.82

Propane: 0.84

Capacity (Gallons 1st Hour @ 90°F rise) Natural Gas: 218

NO x

Emissions (at 3% O

2

)

Hot water capacity, (50°F rise) less than 40 ppm

0.5 to 6.5 GPM

Dimensions

Weight

Connections

Ignition system

Electrical consumption

Water temperature control

Water flow control

Propane: 227

Maximum hot water capacity, (35°F rise) 8.5 GPM

Setpoint Temperature (without remote)

Temperature range with optional remote

Keypads connected

Approved gas type

Factory setting - 120°F

MC controller :

BC and BSC controller :

96 - 140°F

96 - 120°F

Natural or Propane - Ensure unit matches gas type it's being installed on.

Installation Outdoor Installation Only

Height

Width

Depth

46 Lbs.

23 5/8"

13 3/4"

8 7/8"

Gas supply

Cold water inlet

Hot water outlet

Direct electronic ignition

3/4" MNPT

3/4" MNPT

3/4" MNPT

Normal

Standby

Anti-frost protection

63 watts

5.5 watts

84 watts

Simulation feedforward and feedback.

Water flow sensor, electronic water control device, and electronic by-pass control device

Recommended Minimum water supply pressure

Maximum water supply pressure

20 PSI (Rinnai recommends 50-80 PSI for maximum performance)

150 PSI www.rinnai.us

2 Model V2532W

A

S P E C I F I C A T I O N S

Power Supply

Safety devices

Remote control

Appliance - AC 120 Volts - 60Hz.

Remote control DC 12 Volts (Digital)

Flame failure

Boiling protection

-

-

Remaining flame (OHS)

Fusible link

-

-

Flame rod

203°F lockout thermistor

194°F bi-metal switch

264°F thermal fuse

Automatic frost protection

Combustion fan rpm check

Over current

-

-

-

Bi metal sensor & anti-frost heaters

Integrated circuit system

Glass fuse (3 amp)

Main control Kitchen / Laundry MC-45-4US

BC-45-4US

BSC-45-4US Second bathroom control

Remote control cable

Clearances from combustibles

Non-polarized two core cable

Top of heater 12"

Front of heater 24"

Sides of heater

Back of heater

6"

0"

Ground

Top of heater

Front of heater

12"

2"

0" (Do not block or restrict intake or exhaust vents)

Clearances from non-combustibles

Sides of heater

Back of heater

1/2"

0"

Bottom of heater 2"

Installations within RGB-25 Recess Box: Clearances from combustibles to recess box top, bottom, back and sides = 0"

Clearance from Eaves, Porches, Overhangs Top of heater 36"

Minimum and Maximum gas supply pressure

Manifold Gas Pressure

Natural Gas : Minimum 6" W. C.

(NAT.) Maximum 10.5" W. C.

Natural Gas 3.4" W. C. high fire

LPG: 5.1" W. C. high fire

Propane Gas: Minimum 10" W. C.

(LPG) Maximum 13.5 " W. C.

0.56" W. C. low fire

0.88" W. C. low fire

Warranty

Residential: Ten years heat exchanger / five years parts (see unit's warranty for details)

Commercial or Space Heating: No Warranty -- Use V2532WC Water Heater

NOTE: Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice.

Model V2532W 3 www.rinnai.us

L I M I T E D W A R R A N T Y

Rinnai Continuum Water Heater Models: REU-V2532FFU and REU-V2532W

WHAT IS COVERED?

This Warranty covers any defects in materials or workmanship, subject to the terms stated below. This Warranty applies only to products that are installed by a state qualified or licensed contractor. This Warranty applies only if the product is installed within a single family dwelling. This Warranty is void if the installer has not atttended a Rinnai product knowledge class before installing this water heater or if the product is used for any application other than potable water heating in a single family dwelling. This Warranty extends to the original purchaser and subsequent transferees, but only while the product remains at the site of the original installation. This Warranty only extends through the first installation of the product and terminates if the product is moved or reinstalled at a new location.

HOW LONG DOES COVERAGE LAST?

Item

Heat Exchanger

Period of Coverage

10 Years from Date of Purchase*, or

3 Years from Date of Purchase when used as a hot water circulation loop heater.

All other Parts and Components 5 Years from Date of Purchase, or

3 Years from Date of Purchase when used as a hot water circulation loop heater.

WHAT WILL RINNAI DO?

Rinnai will repair or replace the product or any part or component that is defective in materials or workmanship*, except as set forth as follows.

Rinnai will pay reasonable shipping costs, provided you obtain prior authorization from an Authorized Rinnai Distributor. Rinnai will not pay labor charges associated with the repair or replacement of the product or any part or component. All repair parts must be genuine Rinnai parts.

All repairs or replacements must be performed by an individual or servicing company that has been authorized by Rinnai or its distributor.

Replacement of the product or replacement of the heat exchanger may be authorized by Rinnai only. Rinnai does not authorize any person or company to assume for it any obligation or liability in connection with the replacement of a product or heat exchanger. If Rinnai determines that repair of a product is not possible, Rinnai will replace the product with a comparable product, at Rinnai’s discretion.

* If the If the Heat Exchanger fails due to defect in material or workmanship within the sixth (6) through tenth (10) year from date of purchase, Rinnai will make the following allowances toward the purchase of replacement heat exchanger:

Year of Failure Allowance Year of Failure Allowance

6 50% 7 40%

8 30% 9 20%

10 10%

HOW DO I GET SERVICE?

You must contact an Authorized Distributor or Installer for the repair of a defective product under this Warranty. Failure to contact

an Authorized Distributor or Installer will void the Warranty. For the name of the Authorized Distributor or Installer nearest you, please contact your local HVAC dealer or gas service technician, visit the Rinnai website (www.rinnai.us), call Rinnai at 1-800-621-9419 or write to

Rinnai, 103 International Drive, Peachtree City, Georgia 30269.

Proof of purchase is required. You can show proof of purchase with a dated sales receipt, or by completing and mailing the enclosed

Warranty registration card within 30 days of purchasing the product. Please complete the enclosed Warranty registration card and mail

it to Rinnai at the address shown on the card. Receipt of this card by Rinnai will constitute proof-of-purchase for this product. However, return of this Warranty registration card is not necessary in order to validate this Warranty.

WHAT IS NOT COVERED?

This Warranty does not cover any failures or operating difficulties due to accident, abuse, misuse, alteration, misapplication, force majeure, improper installation, improper maintenance or service, water quality, scale buildup, or for any other causes other than defects in materials or workmanship. This warranty does not apply to any product whose serial number or manufacture date has been defaced. This Warranty does not cover any product when used as a pool or spa heater, used for space heating, or used for commercial or business purposes.

This Warranty does not apply if the water supply to the water heater does not meet the National Secondary Drinking Water Regulations, as set forth in the U.S. Code of Federal Regulations, 40 CFR, Chapter 1, Part 143.

Rinnai is not liable for any special, incidental, indirect or consequential damages that may arise, including damage to person or property, loss of use, or inconvenience. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.

LIMITATION ON IMPLIED WARRANTIES

Any implied warranties of merchantability and fitness arising under state law are limited in duration to the period of coverage provided by this limited Warranty, unless the period provided by state law is less. Some states do not allow limitations on how long an implied Warranty lasts, so the above limitation may not apply to you.

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

www.rinnai.us

4 Model V2532FFU

A

C O N T E N T S

Model V2532W

Specifications .............................................................. 2,3

Limited Warranty ........................................................... 4

Owner's Installation Information ................................... 6

Features of your new Continuum ................................ 7

Safety Issues .............................................................. 8,9

Basic Operation ........................................................... 10

About Hot Water ......................................................... 11

Scalds-First Aid ........................................................... 11

Remote Control Operation ......................................... 12

Maintenance Codes .................................................... 13

Maintenance & Service Information...................... 14,15

Trouble Shooting and Common Questions ............... 16

For Your Safety Read Before Operating ................... 17

Operating Instructions ............................................ 17,18

Care & Lime Condition Warning ........................... 18,19

5 www.rinnai.us

A

O W N E R ’ S I N S T A L L A T I O N I N F O R M A T I O N

IMPORTANT!

All Rinnai water heaters MUST be installed by a state qualified or licensed contractor. Failure to comply with your local and state codes pertaining to water heater installations will void the warranty on said water heater(s). It is the responsibility of the person having the unit installed to ensure the contractor has the proper licences and permits for his state. In addition to the above, Rinnai requires all contractors attend a product knowledge class before installing our water heaters.

This requirement MUST be met in order for your product’s warranty to be valid. Failure to comply with your local and state codes will result in non-compliance and void the warranty of the product being installed.

This appliance must be installed in accordance with local codes, or in the absence of local codes, the National Fuel Gas Code, ANSI Z223.1 and/or the

CAN/CGA-B149, Installation Codes.

Install this product outdoors ONLY, DO NOT install indoors.

Do Not use this appliance if any part has been underwater.

Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater.

Detailed instructions on the proper installation practices to follow for the installation of your new continuous hot water heater are included at the back of this manual.

www.rinnai.us

6

Model V2532W

A

F E A T U R E S O F Y O U R N E W C O N T I N U U M

F

The Continuum V2532W is one of the most advanced water heaters available. It produces hot water continuously at the temperature preset in the unit or at the temperature set on the remote temperature controller. Installation of the remote temperature controller is recommended for optimum performance.

F

The Continuum V2532W never runs out of hot water. While electricity, water and gas supplies are connected, the Continuum V2532W will produce hot water whenever the water flow rate through the unit exceeds 0.6 gpm and the temperature rise through the unit exceeds 45°F.

F

The gas burner lights automatically when the hot water tap is opened, and goes out when the tap is closed. Ignition is electronic, there is no pilot light. When the hot water tap is off, no gas is used. You save energy and money with the Continuum V2532W.

F

The temperature of the outgoing hot water is constantly monitored by a built in sensor. If the temperature of the outgoing water rises to more than 6 degrees above the selected temperature (shown on the optional digital remote control) the gas burner will automatically go out. The gas burner will re-ignite once the outgoing hot water temperature falls below the selected temperature.

F

With the remote control installed the water temperature is adjustable from 96 to 140°F with the main controller and from 96 to 120°F with the bath controller. The water temperature cannot be set to a temperature other than 120°F without the use of an optional remote control unit.

F

Error messages are displayed on the remote control units, simplifying service calls.

F

The Continuum V2532W incorporates a device to limit the temperature fluctuations (cold water sandwich effect) when the water is rapidly turned off, then on again. To eliminate the cold water sandwich effect completely, the Continuum V2532W can be installed with a circulation loop, with a small storage tank, as shown on page 26.

F

The sound (noise) level from the Continuum V2532W is very low.

F

The Continuum V2532W is a very compact power vented device. It saves valuable floor and wall space.

Model V2532W 7 www.rinnai.us

A

S A F E T Y I S S U E S

Always check water temperature by hand before entering the shower or bath. The temperature may have been changed.

The water temperature can only be adjusted between 96°F and 110°F when the hot water tap is open, and hot water is flowing.

The Continuum V2532W controls the water temperature automatically. To do this it sometimes needs to change the water flow accordingly. The water flow from the hot water tap may vary after the selected temperature at the Remote Control is altered.

The water flow may also vary from summer to winter, as incoming water temperatures differ.

Depending on the weather conditions and the length of the pipe between the Continuum

V2532W and the tap in use, there may be a variation between the temperatures displayed at the Remote Control and the temperature of the water at the tap.

106 °F www.rinnai.us

8 Model V2532W

A

S A F E T Y I S S U E S

Keep flammable materials, trees, shrubs etc.

away from the Continuum V2532W .

If the external Continuum V2532W is disconnected from the power supply and freezing conditions are expected, turn off water and gas, and drain all water from the appliance.

Water Off

Gas Off

DRAIN

Drain Water FILTER

Do not spray water directly into the flue terminal.

If power and the automatic frost protection are connected, freezing will be prevented in conditions as cold as -30°F.

Do not touch the cover or insert objects into the flue outlet of the Continuum V2532W.

Do not clean Remote Controls with solvents.

Use a soft damp cloth.

On cold days steam may be discharged from the flue outlet, this is normal with a high efficiency appliance and does not indicate a fault.

Model V2532W 9 www.rinnai.us

A

B A S I C O P E R A T I O N

1

Adjusting Temperature

The outlet water temperature of the water heater is adjusted using the Remote

Control thermostats. The temperature can only be adjusted on the Remote Control which has the Priority indicator light glowing. The temperature displayed on this remote control will also be displayed on all other Remote Controls.

3

Simply press the or button until the required temperature is displayed on the

Digital Monitor. There is a hot water scald potential if the thermostat is set to high.

2

To take control of the Continuum V2532W all hot water taps must be closed. Press the "Priority button" on the controller you want to set the temperature with. The

"Priority" indicator light will glow and the

“Set Temperature” display will show the last temperature setpoint for this controller, or the factory setting of 108°F.

4

This indicates that the Continuum V2532W is ready to supply hot water at the set temperature displayed as soon as a tap is opened.

www.rinnai.us

1 0

To operate the Continuum V2532W simply turn any hot water tap on. This will automatically light the burner providing hot water at the preset temperature. If the optional remote controls have been installed, the “IN

USE” indicator will glow on all remote controls.

Note: The Rinnai water heater will not provide hot water instantly at the hot water fixtures. Any cold water existing in the hot water lines must be purged first.

Model V2532W

A

A B O U T H O T W A T E R

Hot Water Is Dangerous, especially for the young and the elderly or the infirm. The Continuum V2532W allows you to precisely control the temperature of your hot water, ensuring safe hot water temperatures.

BURN

Water Temperatures over 125°F can cause severe burns instantly or death from scalds.

Hot Water can cause first degree burns with exposure for as little as:

3 seconds at 140 °F

20 seconds at 130 °F

8 minutes at 120 °F

Test the temperature of the water with your elbow before placing a child in the bath or shower.

Do not leave a child or an infirm person in the bath unsupervised.

S c a l d s F i r s t A i d

1) Remove clothing; Remove all wet clothing, quickly. Wet clothing retains the heat.

2) Apply cold water for 30 minutes; Immediately submerge the burnt area in cold water for 30 minutes to reduce the heat in the skin, preventing deeper burning.

Never use butter, oils or ointment to cover the burn. They may retain the heat.

3) Keep the scalded person warm; Place a blanket around the person.

4) Seek Medical Advice; Call your medical advice hotline and describe the scald, follow their directions.

Model V2532W 1 1 www.rinnai.us

A

R E M O T E C O N T R O L O P E R A T I O N

Digital Monitor

Indicates the selected water temperature.

Maintenance codes flash in the event of a failure.

In Use Indicator

Indicates that a hot water tap is open and that control of the temperature is taken at another controller.

Priority Indicator

Indicates whether this controller has priority control over the water temperature.

Priority Button

Pressing takes control of the water temperature by this controller.

Thermostat

Increase or decrease the desired water temperature.

CAUTION: Hotter water increases the risk of scald injury. Before changing temperature setting, see instruction manual

The Main Controller MC-45-4US is intended to be used in the kitchen, laundry room or utility area, the Bath Controller BC-45-4US and the

S e c o n d B a t h C o n t r o l l e r B S C - 4 5 - 4 U S a r e i n t e n d e d f o r i n s ta l l a t i o n i n bathrooms.

www.rinnai.us

1 2 Model V2532W

A

M A I N T E N A N C E C O D E S

The Continuum V2532W has the ability to check it s own operation continuously. If a fault occurs, a Maintenance Code will flash on the Digital Monitor of the Remote Controls. This assists with diagnosing the fault, and may enable you to overcome a problem without a service call. Please quote the code displayed when inquiring about service.

NOTE: Failure to remedy faults may result in severe burns, scalds, and/or death.

Code

Displayed

Fault Remedy

10

11

12

52

61

71

72

LC

14

16

32

33

Air Supply or Exhaust Blockage

No Ignition

Flame Failure

GroundingFailure

Thermal Fuse

Over Temperature Warning

Outgoing Water Temperature

Sensor Faulty

Heat Exchanger Outgoing Water

Temperature Sensor Faulty

Mod. Solenoid Valve Answer Abnormal

Combustion Fan Failure

Solenoid Valve Driving Circuit Faulty

Flame Sensing Device Faulty

Scale build-up in Heat Exchanger

Check that nothing is blocking the air intake or exhaust.

Check that the gas is turned on at the water heater, gas meter or cylinder.

Check that the gas is turned on at the water heater and gas meter. Check for obstructions in flue outlet.

Service Call

Service Call

Service Call

Service Call

Service Call

Service Call

Service Call

Service Call

Service Call

Model V2532W 1 3 www.rinnai.us

A

M A I N T E N A N C E & S E R V I C E I N F O R M AT I O N

Warning: Always turn off the electrical power supply, the manual gas valve and the manual water control valve whenever servicing the unit.

The Continuum V2532W should be checked by a Rinnai

Certified Technician once a year. A Rinnai Certified

Technician should perform any repairs that may be necessary.

The following items should be checked each inspection:

1) The area around the Continuum V2532W unit should be free from combustible materials such as cloth, vegetation and building materials. (see page 9)

2) Check burners for presence of foreign debris.

3) Remove and clean the inlet water filter.

4) Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

5) Do not obstruct flow of combustion and ventilation air.

In the case of any fault or error message from the Continuum V2532W, first turn all hot water taps off. Wait for 5 seconds. Turn the hot water tap back on. If the error message still remains, call your Rinnai Authorized Service Representative or Rinnai at 800-621-9419.

Should overheating occur or the gas supply fail to shutoff, turn off the manual gas control valve to the appliance.

DO NOT ATTEMPT TO SERVICE YOUR Continuum V2532W YOURSELF.

Call a Rinnai Authorized Service Technician or call Rinnai at 800-621-9419.

www.rinnai.us

1 4 Model V2532W

A

M A I N T E N A N C E & S E R V I C E I N F O R M AT I O N

MAINTENANCE SUGGESTIONS

This water heater has been designed and constructed for a long performance life when installed and operated properly under normal conditions. Regular inspections, as outlined in this section, are strongly recommended as a means of keeping your heater operating efficiently.

1. Cleaning

The water heater must be cleaned annually.

Keep the water heater clear of dust and debris especially in and around burner.

Cleaning procedures for the Continuum are as follows:

1) Turn off and disconnect electrical power. Allow to cool for one hour.

2) Remove the Front Panel by removing screws.

See parts breakdown on panels.

3) Use pressurized air to remove dust from around main burner.

4) Use soft dry cloth to wipe cabinet.

DO NOT DAMAGE OR DISTORT ANY

PARTS OF HEATER.

DO NOT USE WET CLOTH OR

SPRAY CLEANERS ON BURNER.

2. Visual check of main burner flames.

The burner must flame evenly over the entire surface when operating correctly. The flame must burn with a clear, blue, stable flame. See the parts breakdown of the burner for the location of view ports. Any and all parts removed for inspection or service must be replaced before operating the unit.

The flame pattern should be as shown in the following Figures.

* VENT MAINTENANCE

* VENT SYSTEM

Must be checked annually for blockage or deterioration.

* MAINTENANCE-

ELECTRIC MOTORS

Motors are permanently lubricated and need no lubrication. Keep fan and motor free of dust and dirt, clean annually.

Model V2532W 1 5 www.rinnai.us

A

TROUBLE SHOOTING AND COMMON QUESTIONS

Q

- When I was using the hot water, the water got cold!

A

- If you adjusted the flow from the tap to lessen it, you may have gone below the minimum flow required. The Continuum V2532W requires 0.5

GPM to operate. If you mix the water with a tap and attempt to get a temperature well below the temperature being controlled by the unit, it may drop the flow below 0.5 GPM. Decrease the temperature supplied by the Continuum V2532W at the remote control or increase your total flow.

Q

- White smoke comes out of the exhaust!

A

- During colder weather when the exhaust temperature is hotter than the air, the exhaust fumes condense producing white steam.

Q

- When I open a hot tap. I do not immediately get hot water!

A

- Hot water must travel through your plumbing from the Continuum

V2532W to the faucet. This can take up to 2 or more minutes depending upon your plumbing system. If hot water is disired instantly at the hot water fixture, a circulaton loop system must be installed. Please contact your plumber for details.

Q

- After I turn off the hot water tap, the fan on the Continuum V2532W continues to run!

A

- The fan is designed to be on for 65 seconds after the flow of water stops.This is to ensure constant water temperatures during rapid starting and stopping, as well as exhausting any residual gas flue products from the unit.

www.rinnai.us Model V2532W

A

FOR YOUR SAFETY READ BEFORE OPERATING

If you cannot reach your gas supplier, call the fire department.

not try to light the burner by hand.

B. BEFORE OPERATING: Smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

C. Use only your hand to operate remote control keypad. Never use tools. If the remote keypad doesn’t work, do not try to repair it, call a qualified service technician.

Force or attempted repair may result in a fire or explosion.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch, do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

O P E R A T I N G I N S T R U C T I O N S

1) STOP! Read the safety information above before proceeding.

2) Set the thermostat to lowest setting.

3) Turn off all electric power to the appliance.

4) This appliance does not have a pilot. It is equipped with a direct ignition device which automatically lights the burner. Do not try to light the burner by hand.

5) Turn the manual valve located at gas inlet of the appliance clockwise to “OFF”.

Model V2532W

Closed manual valve

(“OFF” position)

Open Manual valve

(“ON” position)

1 7

6) Wait (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information above on this label.

If you don’t smell gas, go to next step.

www.rinnai.us

A

O P E R A T I N G I N S T R U C T I O N S

7) Turn the manual valve located at the gas inlet of appliance counterclockwise to “ON”.

8) Turn on all electric power to the appliance.

9) Set thermostat to desired setting.

10) If the appliance will not operate,

Follow the instructions “To Turn Off

Gas To Appliance” and call your service technician or gas supplier.

To Turn Off Gas To Appliance

1) Set the thermostat to lowest setting.

2) Turn off all electric power to the appliance if service is to be performed.

3) Turn the manual valve at gas inlet of appliance clockwise to “OFF”

C A R E & L I M E C O N D I T I O N W A R N I N G

Care of Unit’s Exterior:

Keep the exterior cabinet clean. Use a soft cloth and warm water when cleaning the cabinet.

Do Not use volatile substances such as benzene and thinners, as they may ignite, or cause fading of the paint.

Lime Condition Warning Signal:

If you notice “LC” flashing on the remote key pad, this means the unit is beginning to lime up, and MUST be flushed. Contact a qualified Rinnai service technician to flush the appliance.

Failure to flush the appliance when “LC” is flashing, will cause damage to the heat exchanger.

Damage caused by lime build up is not covered by the unit’s warranty.

www.rinnai.us

1 8 Model V2532W

A

C A R E & L I M E C O N D I T I O N W A R N I N G

Flush Procedure

V2532W

In

Model V2532W

V2532W

1 9 www.rinnai.us

Installer’s Instructions

All Rinnai water heaters MUST be installed by a state qualified or licensed contractor. Failure to comply with your local and state codes pertaining to water heater installations will void the warranty on said water heater(s). It is the responsibility of the person having the unit installed to ensure the contractor has the proper licences and permits for his state. In addition to the above, Rinnai requires all contractors attend a product knowledge class before installing our water heaters.

This requirement MUST be met in order for your product’s warranty to be valid. Failure to comply with your local and state codes will result in non-compliance and void the warranty of the product being installed.

THE RINNAI V2532W SERIES WATER HEATERS ARE DESIGN

CERTIFIED TO THE ANS Z21.10.3

CSA 4.3 STANDARD FOR

COMMERCIAL WATER HEATERS AND MUST BE INSTALLED

ACCORDING TO THESE INSTRUCTIONS. THE WATER

HEATERS ARE DESIGN CERTIFIED BY CSA INTERNATIONAL.

Contents of Installer’s Manual

Warnings ............................................................ 21

Performance Data ............................................. 22

Locating the Unit ............................................... 23

Dimensions ........................................................ 23

Recommended Piping for Installation ...... 24 - 26

Gas Piping Sizing Charts ................................. 27

Gas Piping Notes .............................................. 28

Water Piping Notes ........................................... 29

Pressure Relief Valve ....................................... 29

Electrical Connection Notes ............................. 30

Wiring Diagram ............................................ 31,32

Lighting the Unit ................................................ 33

Remote Controls .......................................... 34,35

Initial Operation and Testing ............................ 36

Diagnostic Points .............................................. 37

Schematic Diagram ........................................... 38

Exploded View ........................................... 39 - 42

Parts List ................................................... 43 - 47 www.rinnai.us

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

-Warnings-

This manual must be followed exactly.

1) Read the safety issues completely before installing the Continuum V2532W .

2) This water heater is suitable for residential water (potable) heating ONLY. DO

NOT use this water heater for space heating, combination space heating/ domestic water heating, or commercial water heating applications.

3) The Continuum V2532W is not suitable for use in pool or spa applications.

4)

Install the Continuum V2532W water heater outdoors only .

5) Maintain proper space around the unit for proper servicing and operation.

Minimum clearances from combustible materials are listed below.

Top of Heater

Back of Heater

12

0 inches inch

Front of Heater 24 inches

Sides of Heater 6 inches

Ground 12 inches

Minimum clearances from non-combustible materials are listed below.

Top of Heater

Back of Heater

2

0 inches inch

Front of Heater 0 inch

Sides of Heater 1/2 inch

Bottom 2 inches

DO NOT install the Continuum V2532W under an overhang less than 3 feet from the top of the unit. When the overhang protrudes out over the V2532W greater than 3 feet, the area under the overhang must be open on 3 sides.

When the V2532W water heater is installed within a Rinnai RGB-25 recess box, the clearances from the top, bottom, sides, and back sufaces of the recess box to combustible materials are 0 inches. The clearance from combustibles from the front of the recess box is 24 inches.

6) Installer must install a Pressure relief valve. Pipe pressure relief discharge to a drain or outside environment (see page 29).

Model V2532W 2 1 www.rinnai.us

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

C O N T I N U U M O U T L E T F L O W D A T A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

C O N T I N U U M P R E S S U R E D R O P C U RV E www.rinnai.us

2 2 Model V2532W

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Locating the unit

Eve, porche, or overhang

C

A

B

Flue

C/L

E

F

Continuum V2532W

D

Window

Door

Installation clearances Minimum

A.......Ve r t i c a l l y b e l o w a n o p e n a b l e w i n d o w. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 ”

B.......Vertically above an openable window, door, etc...........................12”

C.......Below eves, porches, overhangs...............................................36”

D.......Horizontally from an openable window, door, etc...........................12”

E.......H o r i z o n t a l l y b e t w e e n V 2 5 3 2 W w a t e r h e a t e r s . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 ”

F....... Ve r t i c a l l y b e t w e e n V 2 5 3 2 W w a t e r h e a t e r s . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 ”

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Dimensions

Model V2532W 2 3 www.rinnai.us

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Recommended Piping for Basic Installation

V2532W www.rinnai.us

V2532W

2 4 Model V2532W

A

I N S T A L L E R ’ S I N S T A L L A T I O N I N S T R U C T I O N S

OPTIONAL: Recommended Piping for Power Failure Freeze Protection

V2532W V2532W

V2532W

V2532W

V2532W

V2532W

Model V2532W

V2532W

2 5

V2532W www.rinnai.us

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Recommended Piping for Circulation Systems

V2532W www.rinnai.us

2 6 Model V2532W

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Gas Pipe Sizing Chart – Black Iron Pipe

Capacity Table for Natural Gas cubic feet / hour

(table assumes .3 inch pressure drop, specific gravity of .60)

Length of Pipe in Feet Nominal

Iron Pipe

Size

Inches

3/4

1

10 20 30 40

520 350 285 245

50 60 70 80

278 190 152 130 115 105 96 90

215 195 180 170

90 100 125 150 175 200

84

160

79

150

72

130

64

120

59

110

55

100

1-1/4 1050 730 590 500 440 400 370 350 320 305 275 250 225 210

1-1/2 1600 1100 890 760 670 610 560 530 490 460 410 380 350 320

After determining the length of pipe required select the pipe size that will supply the cubic feet per hour of gas required for the input rating of the Continuum V2532W.

The formula for figuring the cubic feet per hour required is:

CFH =

Gas Input of Continuum V2532W(BTU/HR)

Heating Value of Gas(BTU/FT 3 )

*Gas input requirement is on the water heater data plate

*The heating value of the gas can be obtained from the local Natural Gas Utility

Capacity Table for LP Gas

BTUH of undiluted liquified petroleum gases

(table assumes 11 inches of water column pressure at the inlet, .5 inch drop)

Length of Pipe in Feet Nominal

Iron Pipe

Size

Inches

NOTE: Refer to the National Fuel Gas Code, NFP A 54, for capacity tables for pipe materials other than “Black Iron Pipe”.

Model V2532W 2 7 www.rinnai.us

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Gas Piping Notes

1) A manual gas control valve must be placed upon the gas inlet connection to the

Continuum V2532W before it is connected to the gas line. A union can be used on the connection of the Continuum for the future servicing or disconnection of the unit.

2) Check the type of gas and the gas inlet pressure before connecting the Continuum

V2532W. If the Continuum V2532W is not of the gas type that the building is supplied with, DO NOT connect the water heater. Contact the dealer for the proper unit to match the gas type.

3) Minimum and Maximum Gas pressures are listed below:

* Minimum value is for input adjustment

Natural Gas: *Minimum 7" WC

Maximum 10.5" WC

Prop ane Gas: *Minimum 11" WC

Maximum 13.5" WC

WARNING: Conversion of this unit from natural gas to prop ane or propane to natural gas CANNOT be done in the field.

4) After completion of gas pipe connections, all joints including the heater must be checked for gas-tightness by means of leak detector solution, soap and water, or an equivalent nonflammable solution, as applicable. Caution: Since some leak test solutions, including soap and water, may cause corrosion or stress cracking, the piping must be rinsed with water after testing, unless it has been determined that the leak solution is non-corrosive.

5) The Continuum V2532W must be leak tested before it is placed into operation.

6) The Continuum V2532W and it s individual shut-off valve must be disconnected from the gas supply piping system when pressure testing of the gas supply piping system at test pressures greater than 1/2 psi (3.5 kPa).

7) Always use approved connectors to connect the unit to the gas line. Always purge the gas line of any debris before connection to the water heater.

8) The Continuum V2532W must be isolated from the gas supply piping system by closing it's individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).

9) The Continuum V2532W's Installation location must provide adequate Combustion and Ventilation airflow.

www.rinnai.us

2 8 Model V2532W

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Water Piping Notes

1) A manual water control valve must be placed upon the water inlet connection to the Continuum V2532W before it is connected to the water line. Unions may be used on both the hot/cold water supply lines, for the future servicing or disconnection of the unit.

2) All threaded water piping joints should be made up using Teflon tape, DO NOT use pipe dope.

3) All soldering materials and piping must be compatible with potable water.

4) Purge the water line to remove from it all debris and air. Debris will damage the Continuum V2532W .

5) There is a wire mesh strainer on the Continuum V2532W's inlet to discourage the introduction of debris to the unit. It will need to be cleaned after operating the water heater for the first time, and periodically thereafter. DO NOT operate unit without filter in place.

WARNING: DO NOT reverse the inlet and outlet (cold and hot water) connections on the unit. This would cause the Continuum V2532W to operate dangerously or not at all.

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Pressure Relief Valve

1) ANSI code calls for the addition of an approved pressure relief valve to all water heating systems.

2) The pressure relief valve must meet the following criteria: The relief valve must comply with the standard for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems ANSI

Z21. 22 and/or the standard CAN1-4.4 Temperature, Pressure, Temperature and Pressure Relief

Valves and Vacuum Relief Valves. This relief valve must be rated at 150 PSI of pressure.

3) The relief valve should be added to the hot water outlet line per manufacturer's instructions. DO NOT place any other type valve or shut off device between the relief valve and the hot water heater.

4) The discharge from the pressure relief valve should be piped to the ground or into a drain system to prevent exposure or possible burn hazards to humans or other plant or animal life.

Water discharged from the relief valve could cause severe burns instantly, scalds and/or death.

5) Do not plug the relief valve and do not install any reducing fittings or other restrictions in the relief line. The relief line should allow for complete drainage of the valve and the line.

6) If a relief valve discharges periodically, this may be due to thermal expansion in a closed water supply system. Contact the water supplier or local plumbing inspector on how to correct this situation. Do not plug the relief valve.

7) Pressure relief valve must be manually operated once a year to check for correct operation.

Caution: See Item 4 before manually operating relief valve.

8) Should overheating occur or the gas supply fail to shut off, turn off the manual gas valve on the Continuum V2532W.

Model V2532W 2 9 www.rinnai.us

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Electrical Connection Notes

WARNING: The Continuum V2532W must be electrically grounded in accordance with local codes or in the absence of local codes with the most recent edition of the

National Electrical

Code, ANSl/NFPA 70 and/or the CSA C22.1, Electrical Code.

Do not rely on the gas or water piping to ground the metal parts of the water heater.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

1 The Continuum V2532W requires

120VAC/60 HZ. Power from a properly grounded circuit.

2 An on/off switch must be provided and installed for the incoming 120VAC power.

3 Wire the Continuum V2532W exactly as shown in the wiring diagram on the next page and on the inside of the cover panel. The black wire is the hot leg wire; the white wire is the neutral wire.

4 A ground terminal screw is provided in the junction box for the grounding connection (see diagram).

Your disconnect switch should be a type that is suitable for outdoor use. Check

National Electrical Codes for proper type switch to use in your area.

www.rinnai.us

3 0 Model V2532W

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Wiring Diagram

Model V2532W 3 1 www.rinnai.us

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Wiring Diagram www.rinnai.us

3 2 Model V2532W

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Lighting the Unit

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

1) This water heater does not have a pilot. It is equipped with a direct ignition device which automatically lights the burner. DO NOT TRY TO LIGHT THE

BURNER BY HAND.

2) Before operating the Continuum V2532W smell all around the unit for gas. Be sure to smell near the ground as leaking gas may settle there.

3) Turn the manual gas control valve on.

STOP!! READ THE SAFETY ISSUES ON PAGES 8 & 9

4) Turn on any hot water tap. The Continuum V2532W should light and begin heating your water.

If the Continuum V2532W fails to light

1) DO NOT ATTEMPT TO LIGHT BY HAND.

2) Turn off the electrical power to the unit.

3) Turn off the manual gas control.

4) Wait 5 minutes, if you smell gas, go to a neighbor's house and call the gas company or the fire department. If you do not smell gas, go to the next step.

5) Turn the manual gas control valve on.

6) Turn the electrical power to the unit on.

7) Turn on any hot water tap.

8) If the unit still fails to light, turn off the electricity and gas to the unit and call

Rinnai 1-800-621-9419.

Model V2532W 3 3 www.rinnai.us

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Remote Controls- General

The remote controls for the Continuum V2532W allow the customer to control the functions of the water heater and to diagnose certain fault conditions.

The Main Controller model MC-45-4US is intended to be installed in the kitchen or laundry area where the majority of the hot water is being used.

NOTE: The MC-45-4US has a temperature setpoint range of 96-140°F. This is the only controller capable of temperature setpoints greater than 120°F.

The Bath Controller model BC-45-4US and Secondary Bath Controller model

BSC-45-4US are intended to be installed in a bath room close to a shower or tub. Both of these controllers have temperature setpoint ranges of 96-120°F.

NOTE: Only one of each type of controller can be connected to one Continuum

V2532W water heater. (i.e. Installations with two MC-45-4US, two BC-45-4US, or two BSC-45-4US controllers will not function properly.)

Before installing the remote controls, determine the most convenient location(s).

When deciding on the best location for the remote controls, please consider the following items:

1) Place the controllers out of reach of small children.

2) Avoid locations where the controller(s) will become hot. (over the stove, near the oven or a radiant heater.

3) Avoid direct sunlight. (The digital monitor can be difficult to read in direct sunlight)

4) Avoid areas where the remote can be splashed with cooking water, oil or sauce.

5) The remote control cables carry low voltage, 12VDC digital.

Every installation is different

Continuum V2532W

Continuum V2532W

Series

Parallel

Main Controller

Main Controller Bath Controller

Bath Controller

The controls can be wired in series or in parallel depending on which method is desirable for the distances encountered from the Continuum V2532W to the controls.

www.rinnai.us

3 4 Model V2532W

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Remote Controls - Installation

1) Determine a suitable location for the control.

2) Make three holes on the wall as shown.

3) Run the cable between the control and the Continuum V2532W or the control and the other control.

4) Remove the face plate from the remote control, using a screw driver.

5) Connect the cable to the remote control.

6) Mount the control to the wall using the holes drilled in step 2.

Note: If the cable cannot be run in the wall cavity, the plastic knockout should be removed from the top or bottom of the control to allow flush mounting with the wall

7) Disconnect the power from the Continuum V2532W.

8) Remove the cover of the Continuum V2532W .

9) Remove the plastic cover from the PCB and electrical connections.

DO NOT ATTEMPT TO CONNECT THE REMOTE CONTROLS WITH THE POWER ON,

THERE'S 120 VOLT POTENTIAL, NEXT TO THE REMOTE CONTROL CONNECTIONS

INSIDE THE UNIT. DO NOT CONNECT THE REMOTE CONTROL TO THE 120VAC

TERMINALS PROVIDED FOR THE OPTIONAL SOLENOID DRAIN VALVES. All service and wiring should be performed by a certified installer.

10) Thread the cable through the access hole at the base of the unit and connect the wires to the control terminals labeled “TERMINALS

FOR CONTROLS” on the right hand side bottom of the PCB.

11) Secure the control cable using the clamp provided.

12) Replace plastic cover over PCB and then replace the cover of the

Continuum V2532W.

Model V2532W 3 5 www.rinnai.us

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Initial Operation and Testing

1) Turn on the gas and water.

2) Check for water and gas leaks. Use soapy water to test for gas leaks.

3) Remove pressure test point screw, attach pressure gauge to test point.

4) Turn Power on.

5) Open any hot water tap fully.

6) Check test point or supply pressure in water columns per inch.

Manifold Pressure: Supply pressure:

Natural Gas 3.4" Hi. fire 0.56" Lo. fire Natural Gas Min. 6" Max. 10.5"

LPG 5.1" Hi. fire 0.88" Lo. fire LPG Min. 10" Max. 13.5"

NOTE: The pressure may be low due to too little flow, too high an incoming temperature, and/or undersized gas piping. Examine these areas before determining that the pressure needs to be adjusted. Contact Rinnai before adjusting manifold pressures at 1-800-621-9419. Failure to contact Rinnai, could void unit’s warranty.

7) If it is determined that the gas pressure needs adjusting, first check the in coming pressure at the test point on the gas inlet. If it is correct follow the adjusting procedure contained in the pouch of the unit EXACTLY. If in doubt call Rinnai 1-800-621-9419.

The regulator is pre-set at the factory, it should not need resetting.

8) Turn the hot water off. Turn the power off. Remove the pressure guage and replace the test point screw. Check for a gas leak around the test point screw.

9) Replace the front cover.

10) Turn the power back on.

11) Check the operation of the unit (run for a minimum of 15 minutes). Check the operation of each of the remote controls. Check the operation of the

Power failure protection system.

12) Isolate the water heater from the hot and cold water lines, then remove and clean the inlet water filter screen. Place the water filter back into the water heater and tighten. Open the hot and cold water lines to the water heater and test the operation of the unit.

13) Explain the proper operation of the Continuum V2532W to the customer.

www.rinnai.us

3 6 Model V2532W

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Diagnostic Points

Component

Surge Protector

Water Flow Control Device

By-pass Flow Control Device

Remote Control

Water Flow Sensor

Combustion Fan

Flame Rod

Modulating Valve

Outgoing Thermistor

Heat Exchanger

Outgoing Thermister

Thermal Fuse

Ignitor

Main Solenoid Valve

Solenoid Valve 1

Solenoid Valve 2

Solenoid Valve 3

Primary Windings

Secondary Windings

Measurement Point

Comp. No.

Wire Color

F

7

Blue - Brown

Red-Blue

Gray-Orange

B

1

Gray-Yellow

Gray-Brown

Normal Value

AC 108 - 132 V

DC 11 - 13 V

DC 11 - 13 V

Below DC 1 V (Limiter On)

DC 4 - 6 V (Limiter Off)

Below DC 1 V (Limiter On)

DC 4 - 6 V (Limiter Off)

DC 2 - 6 V

G

1

D

1

Brown-White

Orange-White

Yellow-White

Red-White Gnd

Black-Black

Red - Black

15 - 35

DC 11 - 13 V

DC 11 - 13 V

B

3

Yellow - Black Gnd DC 4 - 7 V (Pulse 17-460 Hz)

A

1

C

1

C

2

B

4

B

5

Red-Black

Yellow-Black

White-Black Gnd

Yellow-Gnd

Yellow-Flame Rod

Pink-Pink

White-White

DC 6 - 45 V

DC 11 - 13 V

DC 5 - 10 V (33-400 Hz)

AC 5 - 150 V

Over DC 1

µA

DC 2 - 15 V

67 - 81

59°F 11.4 - 14.O k

86°F 6.4 - 7.8 k Ω

113°F 3.6 - 4.5 k

140°F 2.2 - 2.7 k

221°F 0.6 - 0.8 k Ω

B

2

C

3

F

8

Red-Red Below 1

E

1

E

2

E

3

E

4

Gray-Gray

Pink - Black

Yellow - Black

Blue-Black

Brown - Black

AC 90 - 110 V

DC 80 - 100 V

1.7 - 2.1 k

DC 80 - 100 V

1.7 - 2.1 k

DC 80 - 100 V

1.7 - 2.1 k

DC 80 - 100 V

1.7 - 2.0 k

TRANSFORMER VOLTAGES AND RESISTANCES

F

7

F

9

Blue-Brown

White-Black

51 - 63

AC 90 - 110 V

Notes

Power Supplied to Unit

Power Supplied to Unit

Full Open Position

Full Close Position

Unit In Operating Mode

On 0.82 gal/min (30 Hz)

Over 1800 pulse/min

Off 0.6 gal/min (20 Hz)

Below 1200 pulse/min

After Ignition

Flame Condition

Model V2532W 3 7 www.rinnai.us

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Schematic Diagram www.rinnai.us

3 8 Model V2532W

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Exploded View - Cabinet

Model V2532W 3 9 www.rinnai.us

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Exploded View - Internals www.rinnai.us

4 0 Model V2532W

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Exploded View - Internals

Model V2532W 4 1 www.rinnai.us

A

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Exploded View - Electrical www.rinnai.us

4 2 Model V2532W

A

Number

001

101

102

103

104

105

106

107

006

007

008

011

002

003

004

005

012

100

108

109

110

110

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Parts List

Description

Front Panel Assembly

Casing Assembly

Wall Installation Bracker

Connection Reinforcement Panel

Heat Protection Plate

Rubber Bushing

Front Panel Packing

Front Panel Packing Side

Seal Packing

Rubber Bushing

Gas Control Assembly

Screw

“Gas Connection (3/4””NPT)”

Burner Unit Assembly

Burner Case Front

Burner Case Bottom Panel

Packing

Lean and Rich

Bunsen Burner Assembly

Burner Case Back Panel

Damper

Manifold Assembly-A (LPG)

Manifold Assembly-C (Nat. G)

Part Number

U245-1110

U245-1100

U195-121

U245-120

U245-107

CF79-41020-A

BU195-167

AU115-163

AU105-113

U245-125

C36E-41-S

AU39-965

CU195-1866

H73-110

CH51-209

H73-112

BH51-218

B3A7-1

CH51-211

H73-115

U245-200-A

U245-200-C

Quantity

1

1

1

16

1

1

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Model V2532W 4 3 www.rinnai.us

A

Number

111

128

132

136

137

138

140

400

401

402

117

118

119

120

122

123

127

112

113

115

116

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Parts List

Description

Packing of Combustion Chamber

Part Number

AU155-207-2

Quantity

1

Lower Packing of Combustion Chamber

Screw

Combustion Chamber Front Plate

Electrode

Flame Rod

Electrode Packing

Electrode Holder

Upper Packing of Combustion Chamber

Fan Casing Assembly

Blower Motor

Fan Connecting Bracket

Fan Connecting Packing

Combustion Chamber Bracket

Flue Outlet

Flue Outlet Packing

Flue Outlet Packing - 6

Heat Exchanger Complete Assembly

“Water Inlet (3/4”NPT)

Water Flow Servo & Sensor Assembly

Rectifier

AU183-562

U245-255

U245-1130

U245-1122

AH24-653-6

U245-1310

H73-501-2

M8E-6-5

M8D1-15

H73-214

C10D-5

U245-261

H73-120

AH41-216

AH66-398

AH66-393

U245-262

CH51-615

H89-261

BH29-606

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1 www.rinnai.us

4 4 Model V2532W

A

Number

403

710

711

715

716

717

704

705

706

707

708

709

404

405

406

407

408

409

410

411

702

703

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Parts List

Description

By-pass Servo Assembly

Stop Bracket

Plug Band

Water Filter Assembly

Filter Plug

Hot Water Outlet (3/4”NPT)

Stop Bracket

Plug Band Small

Drain Valve

PCB Cover-Side

PCB Cover-Front

Transformer Assembly

PCB Bracket

Ignitor

High Tension Cord

Electrode Sleeve

Thermistor

Thermistor Clip Large

Thermal Fuse Clip

120V Valve Heater Assembly

Anti-Frost Heater Clip

Anti-Frost Heater Clip A

Part Number

M6J-1-3

ET-281

U245-257

EI-189

BH38-710-240

AU206-218

BH45-650

CP-90172

U217-676

U245-622

CF29-742

AU111-653

AH69-310

H73-512

H73-511

H73-510

U245-865-3

AU162-1876

AU103-413

AU142-444

U245-774

BU168-707

Quantity

1

1

2

1

5

1

1

1

1

2

1

1

1

1

1

1

2

1

1

1

1

1

Model V2532W 4 5 www.rinnai.us

A

Number

718

808

809

810

812

813

802

803

804

805

806

807

725

726

730

731

720

721

722

723

732

733

734

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Parts List

Description

Anti-Frost Heater Clip

Power Supply Harness

Fuse Harness

100V Harness

Solenoid Valve Harness

Thermal Fuse Harness

Mold-Type Over Heat Switch

PCB

Surge Protector

Frost Sensing Switch

120V Anti-Frost Heater Assembly

Sensor Harness - 2

Washer

Screw

Screw

Screw

Screw

Screw

Screw

Screw

O-ring

O-ring

O-ring

Part Number

AU100-721

AU33-184

CP-21478-412

U217-449

ZAA0408UK

ZBD0508UK

AU48-174

ZBA0510UK

ZAD0408TK

M10B-2-4

M10B-13-4

M10B-2-18

AU195-1876

BU195-1630

U245-601

U245-602

U245-610

BU129-824-2

U245-1200

BU195-1873

H73-750

U245-1320

U245-603-2

Quantity

1

2

1

4

4

2

1

3

2

2

4

3

1

1

1

1

1

1

1

1

1

1

1 www.rinnai.us

4 6 Model V2532W

A

Number

814

888

-

-

-

-

-

815

816

817

818

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Parts List

Description

O-ring

O-ring

O-ring

O-ring

Packing

V2532W Owner’s Manual

Package Spec Sheet

“Manual 3/4”” gas control valve”

Kitchen remote control kit

Bathroom remote control kit

2nd Bathroom remote control kit

Part Number

M10B-2-16

M10B-2-14

M10B-2-7

M10B-1-24

C36E1-6

U245-1360

PWB-261

BU195-1865

MC-45-4US

BC-45-4US

BSC-45-4US

Quantity

2

1

1

1

1

1

1

2

1

1

2

Model V2532W 4 7 www.rinnai.us

A

A

sk about Rinnai’s other fine products:

The Silent Servant

*North America’s only vent-free convection heater

*99% efficient

*whisper quiet

*perfect for hard to heat areas

The Energy Savers

*Direct Vent Heating with style and performance

*whisper quiet

*available with multi-step set back thermostats

The Infra-reds

*Vent free radiant heaters

*99.9% efficient

*Heat like the sun

Cooking Products

*Rice Cookers

*Korean Griddle

*Portable one, two and two burner with broiler models.

(Perfect for camping, a picnic or a tailgate party www.rinnai.us

U245-1360 ˜01

Printed in Japan 2003.05

www.rinnai.us

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals