Sartorius | User manual | FC06BBE-SX

Add to my manuals
6 Pages

advertisement

Sartorius | User manual | FC06BBE-SX | Manualzz

Competence for safety

Factory Ex series

Zone 1

Precision scales from 0.001 g to 300 kg

The latest weighing technology for reliable results – even in hazardous areas:

Factory Ex scales

These industrial scales combine the extensive experience

Sartorius has in advanced weighing technology with the latest types of explosion protection.

Monolithic weigh cell technology makes these scales both rugged enough for industrial environments and exceptionally accurate.

These characteristics interact perfectly with sophisticated filter algorithms to guarantee reliable measurements. The advantages for your production process:

– Improved long-term stability of weighing data

– Enhanced performance even in fluctuating temperatures

– High stability for off-center loading

– Excellent repeatability and linearity

– High mechanical capacity

– Electrical preload compensation of up to 20 % of the weighing capacity

Indicators for Factory Ex precision scales

Both indicator models have backlit graphical displays. For your ease of use, the operating menu lets you customize the display (digit size, optional information, display inversion, contrast, etc.) and activate a bar graph display as an aid in filling. The backlighting ensures good readability even under adverse conditions. Textsupported operator guidance facilitates handling and configuration in every application.

The FC indicator

On FC scales with weighing capacities up to 64 kg, the indicators are made of rugged industrial plastic. The FC indicator comes pre-installed on a column. A bracket is included for optional front-mounting on the platform (standard cable length: 1.7 m). Alternatively, a

2.7-m cable is available for remote operation.

The indicator can also be set up for remote use for individual user guidance (xBPI-functions).

Factory Ex scales come with a wide array of application programs: checkweighing, net–total formulation, weighing in percent, statistics, totalizing, recalculation, differential weighing, calculation of weight values, and mass unit conversion.

FC models have both power jack and data output port on the weighing platform.

They also offer several additional functions for combination: second tare memory, ID codes, product data memory and user-definable printout design.

All Factory scales are equipped with built-in motorized calibration weights, so you can check the scale's accuracy by simply pressing a key.

A choice of five power supply versions (see photo) for installation in hazardous or non-hazardous areas gives you even more flexibility.

The RS-232C interface ensures secure data transfer over barriers or interface converters to the non-hazardous area; e.g., to a printer or computer (RS-485 and RS-422 also available).

The FCA indicator

For models with weighing capacities from 12 to 300 kg,

FCA indicator models are available in brushed AISI type

316 Ti stainless steel (1.4571) with an electropolished front panel. The keys are logically grouped and large enough to operate even when wearing heavy gloves. FCA indicators are equipped for separate installation (cable length 6 m/~20 ft; optionally up to 10 m/~50 ft).

Furthermore, the dimensions are compliant with the German

DIN 43700 standard for easy installation in control panels.

Factory Ex scales can be networked with up to 8 client devices.

FCA models have both power jack and data output port on the indicator.

Typical example of Ex scale installation in Zone 1

Hazardous area Non-hazardous area

Power supply

(110 V–230 V) a 24 V module b Power supply

(110 V–230 V) c Rechargeable battery a 24 V module d

RS-232C|RS-485|

TTY|RS-422 ib

Interface converter or Zener barrier

Computer

Design A

FC scale

Foot switch

PLC

Power supply cable lengths for Factory Ex

Maximum lengths for power supply options

(secondary cable)

Standard a 5 m b 3 m c 2 m d 20 m

Optionally up to

20 m

20 m

20 m

Printer

Maximum lengths permitted between intrinsically safe data output and Zener barrier

(in non-hazardous area) or interface converter

(in non-hazardous area or Zone 2) with RS-232C data output up to 20 m* with RS-422 data output up to 1200 m with RS-485 data output up to 1200 m with TTY data output up to 300 m

(depends on baud rate)

* RS-232C standard guarantees 15 m.

Factory Ex scales in a network (up to 8 scales)

Hazardous area Non-hazardous area

Model

Weighing capacity

Readability

Load plate dimensions

Dust and water protection

Built-in motorized calibration weight

Net weight

Design

Model/verified ex-factory

Verification scale interval

Minimum sample quantity acc. to CD*

Minimum sample quantity acc. to

European prepackage regulations

* Complies with Council Directive 90/384/EEC on no

Factory FCA

Factory Factory

Factory FCA

RS-485

Interface converter or Zener barrier

PLC or computer

Model

Weighing capacity

Readability

Load plate dimensions

Dust and water protection

Built-in motorized calibration weight ture

Net weight FC..EDE-X

Net weight FCA..EDE-X

Design

ATEX approval for Factory scales: For use in Zone 1 or 2 hazardous areas

ATEX designation h

II 2 G EEx ib IIC T4

for gases (Zone 1)

Category 2

Apparatus group

Certified in acc. with CENELEC standards

Explosion-protected

Type of protection: "Intrinsic Safety"

Highest gas group (ll C)

Temperature class for use in hazardous areas containing potentially explosive gas

Model/verified ex-factory

Verification scale interval

Minimum sample quantity acc. to 90/38

Design B Design C Design D Design E kg g mm

Approx. kg

FC06BBE-SX

0.62

0.001

d 130

IP54

Standard feature

7 a

FC2CCE-SX

2.2

0.01

216 + 200

IP54

Standard feature

7,5 b

FC6CCE-HX

6.2

0.01

216 + 200

IP54

Standard feature

9 b

FC6CCE-SX

6.2

0.1

216 + 200

IP54

Standard feature

7.5

b

FC12CCE-SX

12

0.1

216 + 200

IP54

Standard feature

7.5

b g g

All models: accuracy class K

FC06BBE-SXCE FC2CCE-SXCE

0.01

0.02

0.1

0.5

FC6CCE-HXCE

0.1

0.5

FC6CCE-SXCE

1

5 g 0.02

0.5

0.5

5 on-automatic weighing instruments in the European Union and Signatories of the Agreement on the European Economic Area

FC12CCE-SXCE FC12CCE-IXCE

1

5

0.5

25

5 50 g

4 EEC g kg g mm kg kg

FC12EDE-PX FC16EDE-HX

FCA12EDE-PX FCA16EDE-HX

FC34EDE-PX FC34EDE-HX FC64EDE-SX* FCA150IGG-HX FCA300IGG-HX

FCA34EDE-PX FCA34EDE-HX FCA64EDE-SX

6|12

0.1|0.2

16

0.1

8|16|34

0.1|0.2|0.5

34

0.1

64

1

150

1

300

2

300 + 400

IP65

300

IP65

+ 400 300

IP65

+ 400 300

IP65

+ 400 300

IP65

+ 400 300

IP65

+ 400 300

IP65

+ 400

Standard feature Standard feature Standard feature Standard feature Standard feature Standard feature Standard fea-

16

17.5

16

17.5

c|d c|d

(=FCA models) (=FCA models)

16

17.5

16

17.5

c|d c|d

(=FCA models) (=FCA models)

16

17.5

c|d

(=FCA models)

68.5

– e

68.5

– e

* FC|FCA64EDE-HX with 64 kg|0.1 g; available with IP44 Protection

All models: accuracy class K

FC12EDE-PXCE FC16EDE-HXCE FC34EDE-PXCE FC34EDE-HXCE FC64EDE-SXCE FCA150IGGFCA300IGG-

FCA12EDE-PXCE FCA16EDE-HXCE FCA34EDE-PXCE FCA34EDE-HXCE FCA64EDE-SXCE HXCE HXCE

1 1 1 1 10 20

5 – 5 5 – 50 1000

Accessories for Factory Ex

Description

Power supplies configurable power supply in Ex-area, Europe configurable power supply outside EX, Europe

Power supply outside hazardous area

(110 to 240 V) for US

Power supply inside the hazardous area

(110 to 240 V) for US

EX rechargeable battery for Zone 1, 21, 20

24 V industrial power supply module (for use inside and outside the hazardous area; installation in 14" control cabinet)

Interfaces

Order No.

YPSC01-X

YPSC01-Z

YPS02-ZKR

YPS02-XKR

YRB02-X

YPS02-XV24

Interface converter for installation in the non-hazardous area or Zone 2 or 22 for connecting peripheral devices in the nonhazardous area; intrinsically safe data interfaces: RS-232C, RS-485, RS-422, TTY,

4 digital I/O; data interfaces in the nonhazardous area: RS-232C, RS-485, RS-422,

TTY, 4 digital I/O

Data output: TTY 10mA for FC–BBE|CCE-X

YCO01-Y

YDO01FC-X

Data output: TTY 10mA for FC-EDE-X models YDO4FC-X

Data output: TTY 10mA for FCA-X models YDO1FT-X

Data output: RS-485 (e.g., for connecting the scale in a bus network in the hazardous area) for FC-BBE|CCE-X for FC-EDE-X for FCA-X

YDO02FC-X

YDO03FC-X

YDO02FT-X

Data output: RS-422 for FCA scales for FC-BBE|CCE-X for FC-EDE-X

YDO03FT-X

YDO05FC-X

YDO06FC-X

Cables (for connecting an interface converter)

Cable with open ends (1 pc = 1 m): LiY6x

(2 +0m 14C) Y; casing color: blue; recommended e.g. for RS-422 or digital

IN interfaces YCC422-X

Cable with open ends (1 pc = 1 m): LiY6x

(2 +0m 14C) Y; casing color: blue; recommended e.g. for RS-232 interface

Cable with open ends (1 pc = 1 m): 5 +0.52

LiYCY; casing color: blue; recommended e.g. for 10 mA TTY 10 interface (fits optional

TTY COM ports)

YCC232-X

YCCTTY10-X

Cable with open ends (1 pc = 1 m): 2 +0.22

LiYCY; casing color: blue; recommended e.g. for RS-485 interface

Connecting cable between platform and indicator for FC..BBE|CCE models; 2.7 m

YCC485-X

YCC01-0019M3

Description

Connecting cable between platform and indicator for FC..EDE models; 2.7 m

Cable with open ends (1 pc = 1 m):

6x2xAWG24; recommended e.g. for RS-422, digital OUT and RS-232C ports

Order No.

YCC01-0018M3

YCC422-Y

14-pin male connector for customized cables for networks

Mechanical Accessories*

69Y03166

Wrap-around load plate (water protection) for FC6CCE-S, IS12CCE-SX YLP01

Drive-on ramp for IGG models (1250 +600 mm; painted steel), incl. installation kit YAR10IS

Frame for pit installation (painted steel) for platform dimensions 800 +600

Frame for pit installation (stainless steel) for platform dimensions 800 +600

Installation kit (stainless steel) for pit installation frame (required for installation of YEG01IP|YEG04IP)

YEG04IP

YEG01IP

YAS04IS

Floor-mounted column, 1.1 m (~44 in) high YDH03IS

Adapter plate, steel, for attaching an

FCA indicator to a YDH03IS floor-mounted column

Adjustable display holder for wall mounting

(also for FC-X in a network)

Dust cover for FCA indicator

Electrical Accessories

YAS01FCT-X

YDH01F

6960FC01

Zener barrier (2 data lines) for connecting up to max. 8 scales (RS-485 data output port required) with cable acc. to requirements YDI01-Z

Zener barrier (4 data lines) for connecting accessories in the non-hazardous area; e.g., printer or computer; cable length from scale to Zener barrier: 20 m (~66 ft)

Zener barrier/4 data lines/control lines)

Barrier (2 data lines)

RS-232C to RS-232C incl. 20 m cable

Barrier (2 data lines)

RS-422 to RS-232C incl. 20 m cable

Charger for YRB02-X (in the non-hazardous area)

Foot switch for activating tare or print, cable length: 2 m (~6.5 ft)

YDI02-Z

YDI03-Z

YDI05-Z

+ Option M52

YDI05-Z

+ Option A25

+ Option M54

YRB02LD

YPE05-X

WLAN-EX adapter CIXS3

WLAN-EX battery pac

YWL01-X

YWL01RB-X

* ATEX-certified roller conveyor available on request?

Sartorius AG

Weender Landstrasse 94–108

37075 Goettingen, Germany

Phone +49.551.308.0

Fax +49.551.308.3289

[email protected]

www.sartorius-mechatronics.com

Specifications subject to change without notice.

Printed in Germany on paper that has been bleached without any use of chlorine.

Publication No.: WF-1006-e08122

Order No.: 98649-006-20

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement