advertisement
Competence for safety
Factory Ex series
Zone 1
Precision scales from 0.001 g to 300 kg
The latest weighing technology for reliable results – even in hazardous areas:
Factory Ex scales
These industrial scales combine the extensive experience
Sartorius has in advanced weighing technology with the latest types of explosion protection.
Monolithic weigh cell technology makes these scales both rugged enough for industrial environments and exceptionally accurate.
These characteristics interact perfectly with sophisticated filter algorithms to guarantee reliable measurements. The advantages for your production process:
– Improved long-term stability of weighing data
– Enhanced performance even in fluctuating temperatures
– High stability for off-center loading
– Excellent repeatability and linearity
– High mechanical capacity
– Electrical preload compensation of up to 20 % of the weighing capacity
Indicators for Factory Ex precision scales
Both indicator models have backlit graphical displays. For your ease of use, the operating menu lets you customize the display (digit size, optional information, display inversion, contrast, etc.) and activate a bar graph display as an aid in filling. The backlighting ensures good readability even under adverse conditions. Textsupported operator guidance facilitates handling and configuration in every application.
The FC indicator
On FC scales with weighing capacities up to 64 kg, the indicators are made of rugged industrial plastic. The FC indicator comes pre-installed on a column. A bracket is included for optional front-mounting on the platform (standard cable length: 1.7 m). Alternatively, a
2.7-m cable is available for remote operation.
The indicator can also be set up for remote use for individual user guidance (xBPI-functions).
Factory Ex scales come with a wide array of application programs: checkweighing, net–total formulation, weighing in percent, statistics, totalizing, recalculation, differential weighing, calculation of weight values, and mass unit conversion.
FC models have both power jack and data output port on the weighing platform.
They also offer several additional functions for combination: second tare memory, ID codes, product data memory and user-definable printout design.
All Factory scales are equipped with built-in motorized calibration weights, so you can check the scale's accuracy by simply pressing a key.
A choice of five power supply versions (see photo) for installation in hazardous or non-hazardous areas gives you even more flexibility.
The RS-232C interface ensures secure data transfer over barriers or interface converters to the non-hazardous area; e.g., to a printer or computer (RS-485 and RS-422 also available).
The FCA indicator
For models with weighing capacities from 12 to 300 kg,
FCA indicator models are available in brushed AISI type
316 Ti stainless steel (1.4571) with an electropolished front panel. The keys are logically grouped and large enough to operate even when wearing heavy gloves. FCA indicators are equipped for separate installation (cable length 6 m/~20 ft; optionally up to 10 m/~50 ft).
Furthermore, the dimensions are compliant with the German
DIN 43700 standard for easy installation in control panels.
Factory Ex scales can be networked with up to 8 client devices.
FCA models have both power jack and data output port on the indicator.
Typical example of Ex scale installation in Zone 1
Hazardous area Non-hazardous area
Power supply
(110 V–230 V) a 24 V module b Power supply
(110 V–230 V) c Rechargeable battery a 24 V module d
RS-232C|RS-485|
TTY|RS-422 ib
Interface converter or Zener barrier
Computer
Design A
FC scale
Foot switch
PLC
Power supply cable lengths for Factory Ex
Maximum lengths for power supply options
(secondary cable)
Standard a 5 m b 3 m c 2 m d 20 m
Optionally up to
20 m
20 m
20 m
–
Printer
Maximum lengths permitted between intrinsically safe data output and Zener barrier
(in non-hazardous area) or interface converter
(in non-hazardous area or Zone 2) with RS-232C data output up to 20 m* with RS-422 data output up to 1200 m with RS-485 data output up to 1200 m with TTY data output up to 300 m
(depends on baud rate)
* RS-232C standard guarantees 15 m.
Factory Ex scales in a network (up to 8 scales)
Hazardous area Non-hazardous area
Model
Weighing capacity
Readability
Load plate dimensions
Dust and water protection
Built-in motorized calibration weight
Net weight
Design
Model/verified ex-factory
Verification scale interval
Minimum sample quantity acc. to CD*
Minimum sample quantity acc. to
European prepackage regulations
* Complies with Council Directive 90/384/EEC on no
Factory FCA
Factory Factory
Factory FCA
RS-485
Interface converter or Zener barrier
PLC or computer
Model
Weighing capacity
Readability
Load plate dimensions
Dust and water protection
Built-in motorized calibration weight ture
Net weight FC..EDE-X
Net weight FCA..EDE-X
Design
ATEX approval for Factory scales: For use in Zone 1 or 2 hazardous areas
ATEX designation h
II 2 G EEx ib IIC T4
for gases (Zone 1)
Category 2
Apparatus group
Certified in acc. with CENELEC standards
Explosion-protected
Type of protection: "Intrinsic Safety"
Highest gas group (ll C)
Temperature class for use in hazardous areas containing potentially explosive gas
Model/verified ex-factory
Verification scale interval
Minimum sample quantity acc. to 90/38
Design B Design C Design D Design E kg g mm
Approx. kg
FC06BBE-SX
0.62
0.001
d 130
IP54
Standard feature
7 a
FC2CCE-SX
2.2
0.01
216 + 200
IP54
Standard feature
7,5 b
FC6CCE-HX
6.2
0.01
216 + 200
IP54
Standard feature
9 b
FC6CCE-SX
6.2
0.1
216 + 200
IP54
Standard feature
7.5
b
FC12CCE-SX
12
0.1
216 + 200
IP54
Standard feature
7.5
b g g
All models: accuracy class K
FC06BBE-SXCE FC2CCE-SXCE
0.01
0.02
0.1
0.5
FC6CCE-HXCE
0.1
0.5
FC6CCE-SXCE
1
5 g 0.02
0.5
0.5
5 on-automatic weighing instruments in the European Union and Signatories of the Agreement on the European Economic Area
FC12CCE-SXCE FC12CCE-IXCE
1
5
0.5
25
5 50 g
4 EEC g kg g mm kg kg
FC12EDE-PX FC16EDE-HX
FCA12EDE-PX FCA16EDE-HX
FC34EDE-PX FC34EDE-HX FC64EDE-SX* FCA150IGG-HX FCA300IGG-HX
FCA34EDE-PX FCA34EDE-HX FCA64EDE-SX
6|12
0.1|0.2
16
0.1
8|16|34
0.1|0.2|0.5
34
0.1
64
1
150
1
300
2
300 + 400
IP65
300
IP65
+ 400 300
IP65
+ 400 300
IP65
+ 400 300
IP65
+ 400 300
IP65
+ 400 300
IP65
+ 400
Standard feature Standard feature Standard feature Standard feature Standard feature Standard feature Standard fea-
16
17.5
16
17.5
c|d c|d
(=FCA models) (=FCA models)
16
17.5
16
17.5
c|d c|d
(=FCA models) (=FCA models)
16
17.5
c|d
(=FCA models)
68.5
– e
68.5
– e
* FC|FCA64EDE-HX with 64 kg|0.1 g; available with IP44 Protection
All models: accuracy class K
FC12EDE-PXCE FC16EDE-HXCE FC34EDE-PXCE FC34EDE-HXCE FC64EDE-SXCE FCA150IGGFCA300IGG-
FCA12EDE-PXCE FCA16EDE-HXCE FCA34EDE-PXCE FCA34EDE-HXCE FCA64EDE-SXCE HXCE HXCE
1 1 1 1 10 20
5 – 5 5 – 50 1000
Accessories for Factory Ex
Description
Power supplies configurable power supply in Ex-area, Europe configurable power supply outside EX, Europe
Power supply outside hazardous area
(110 to 240 V) for US
Power supply inside the hazardous area
(110 to 240 V) for US
EX rechargeable battery for Zone 1, 21, 20
24 V industrial power supply module (for use inside and outside the hazardous area; installation in 14" control cabinet)
Interfaces
Order No.
YPSC01-X
YPSC01-Z
YPS02-ZKR
YPS02-XKR
YRB02-X
YPS02-XV24
Interface converter for installation in the non-hazardous area or Zone 2 or 22 for connecting peripheral devices in the nonhazardous area; intrinsically safe data interfaces: RS-232C, RS-485, RS-422, TTY,
4 digital I/O; data interfaces in the nonhazardous area: RS-232C, RS-485, RS-422,
TTY, 4 digital I/O
Data output: TTY 10mA for FC–BBE|CCE-X
YCO01-Y
YDO01FC-X
Data output: TTY 10mA for FC-EDE-X models YDO4FC-X
Data output: TTY 10mA for FCA-X models YDO1FT-X
Data output: RS-485 (e.g., for connecting the scale in a bus network in the hazardous area) for FC-BBE|CCE-X for FC-EDE-X for FCA-X
YDO02FC-X
YDO03FC-X
YDO02FT-X
Data output: RS-422 for FCA scales for FC-BBE|CCE-X for FC-EDE-X
YDO03FT-X
YDO05FC-X
YDO06FC-X
Cables (for connecting an interface converter)
Cable with open ends (1 pc = 1 m): LiY6x
(2 +0m 14C) Y; casing color: blue; recommended e.g. for RS-422 or digital
IN interfaces YCC422-X
Cable with open ends (1 pc = 1 m): LiY6x
(2 +0m 14C) Y; casing color: blue; recommended e.g. for RS-232 interface
Cable with open ends (1 pc = 1 m): 5 +0.52
LiYCY; casing color: blue; recommended e.g. for 10 mA TTY 10 interface (fits optional
TTY COM ports)
YCC232-X
YCCTTY10-X
Cable with open ends (1 pc = 1 m): 2 +0.22
LiYCY; casing color: blue; recommended e.g. for RS-485 interface
Connecting cable between platform and indicator for FC..BBE|CCE models; 2.7 m
YCC485-X
YCC01-0019M3
Description
Connecting cable between platform and indicator for FC..EDE models; 2.7 m
Cable with open ends (1 pc = 1 m):
6x2xAWG24; recommended e.g. for RS-422, digital OUT and RS-232C ports
Order No.
YCC01-0018M3
YCC422-Y
14-pin male connector for customized cables for networks
Mechanical Accessories*
69Y03166
Wrap-around load plate (water protection) for FC6CCE-S, IS12CCE-SX YLP01
Drive-on ramp for IGG models (1250 +600 mm; painted steel), incl. installation kit YAR10IS
Frame for pit installation (painted steel) for platform dimensions 800 +600
Frame for pit installation (stainless steel) for platform dimensions 800 +600
Installation kit (stainless steel) for pit installation frame (required for installation of YEG01IP|YEG04IP)
YEG04IP
YEG01IP
YAS04IS
Floor-mounted column, 1.1 m (~44 in) high YDH03IS
Adapter plate, steel, for attaching an
FCA indicator to a YDH03IS floor-mounted column
Adjustable display holder for wall mounting
(also for FC-X in a network)
Dust cover for FCA indicator
Electrical Accessories
YAS01FCT-X
YDH01F
6960FC01
Zener barrier (2 data lines) for connecting up to max. 8 scales (RS-485 data output port required) with cable acc. to requirements YDI01-Z
Zener barrier (4 data lines) for connecting accessories in the non-hazardous area; e.g., printer or computer; cable length from scale to Zener barrier: 20 m (~66 ft)
Zener barrier/4 data lines/control lines)
Barrier (2 data lines)
RS-232C to RS-232C incl. 20 m cable
Barrier (2 data lines)
RS-422 to RS-232C incl. 20 m cable
Charger for YRB02-X (in the non-hazardous area)
Foot switch for activating tare or print, cable length: 2 m (~6.5 ft)
YDI02-Z
YDI03-Z
YDI05-Z
+ Option M52
YDI05-Z
+ Option A25
+ Option M54
YRB02LD
YPE05-X
WLAN-EX adapter CIXS3
WLAN-EX battery pac
YWL01-X
YWL01RB-X
* ATEX-certified roller conveyor available on request?
Sartorius AG
Weender Landstrasse 94–108
37075 Goettingen, Germany
Phone +49.551.308.0
Fax +49.551.308.3289
www.sartorius-mechatronics.com
Specifications subject to change without notice.
Printed in Germany on paper that has been bleached without any use of chlorine.