advertisement
Fiber Optic Multiplexer
-FRM220 Family
PDH Fiber Optic Multiplexer
Platform
FMUX20
The FMUX20 is a 2U high 19" Rack, 20-slot modular Fiber Optic Multiplexer rack, It provides an economic solution in high density fiber multiplexer installations in central offices. All critical components, Power, fans, management module and interface cards are hot swappable, allowing online field replacement. The hot-swappable power modules can be chosen from
AC100-240V, DC18-36. or DC 36-72V. The chassis also has a pair of alarm relays and is able to stack up to 10 chassis as one management unit.
Features
• 2U 19” 20-slot Chassis with AC/DC power redundancy
• Chassis cascade up to 10 with one IP management
• Chassis backplane consists of passive components
• All modules and cards support hot-swap function
• Two alarm relays
Port
Indication
Power Input
Power Consumption
Dimensions
Weight
Temperature
Humidity
Certification
MTBF
Network Management Controller Card :
Electrical Interface : Console RS232,
LAN 10/100Base-TX
Network Management Controller Card:
Power, FAN Alarm, Act, STK, LAN LNK/SPD
Gigabit Ethernet Switch Card
FAN, PWR, ALM, STK, LNK/ACT/SPD
AC : 100 ~ 240V
DC24 : 18 ~ 36V, DC48: 36 ~ 72V
150W
303 x 438 x 88 mm (D x W x H)
5.2g
0 ~ 50 °C (Operating),
-10 ~ 70 °C (Storage)
5 ~90% non-condensing
CE, FCC, RoHS
65,000 hrs (25 °C)
20 slot
Fiber Optic Multiplexer
Platform
Technologies Supported:
Fiber Optic Multiplexer
Chassis backplane consists of passive components
Chassis cascade up to 10 with one IP management
Hot swappable
Thermal fans
2-101
FMUX20
Two Alarm relays
Single or optional redundant power supplies www.ctcu.com
Fiber Optic Multiplexer -FRM220 Family
Power Redundancy
All the FMUX20 chassis power supplies are hot swappable and modular, installing two into a chassis provides redundancy should a single power supply fail. A fully loaded chassis can run continuously with only one power module fitted into the chassis.
Intelligent Cooling Fan
To further increase system reliability, the FMUX20 chassis is fitted with two hot swappable fan modules. Both fan modules can be easily removed from the rear of the chassis, without interruption to the operation of the line cards. A fully loaded chassis can run continuously with only one fan module fitted into the chassis
Chassis cascade
The FMUX20 features cascadeable management which allows managing a stack (up to 10 chassis) from a single IP address. Chassis are interconnected with standard UTP cables that carry control signals. Each chassis has its own
ID, starting with the master chassis ID0 and cascading up to ID9
Master
Slave 1
UTP cable
Network Management
The FMUX20 chassis provides an NMC (Network
Management Controller) card which must be installed into the first slot of chassis. The NMC card allows a network administrator with the ability to configure and monitor the status of the blades. Management can be achieved locally over RS232, or over the network by Telnet, Web or
SNMP.
Slave 9
10 chassis cascade with one IP management
Protocol Supported
The FMUX20 chassis has been designed as a Fiber Mux Managed platform. This allows network administrators to deploy the chassis in a wide range of Fiber Mux network. Technologies supported by the chassis included Ethernet Fiber Optic Multiplexer.
2
Slide-in card overview
Fiber Optical Multiplexer
Fiber Optical Multiplexer
FOM04
Functions
●
●
●
●
●
●
●
●
●
4 channels unframed E1/T1
10/100Base-TX Ethernet
Auto MDI/MDIX
Auto-Negotiation or Force mode
Supports flow control
Supports 9K jumbo packets
Supports Link fault pass through (LFP)
One clear channel RS232 up to 250Kbps(Async)
1+1 fiber protection, less than 50ms
●
●
●
●
●
●
●
Supports Digital Diagnostics Monitoring Interface (DDMI)
AIS on signal loss on E1/T1 and fiber port
Loopback test on E1/T1, LAN, RS232, fiber ports
Supports Dying Gasp
Supports local or remote In-band management
(Monitor or Configure status) by SNMP manager and console port.
Supports Order wire Ear / Microphone port.
Supports On-Line F/W upgrade.
Ordering Information
FMUX20 Chassis
FMUX20-CH20 : 2U 19” 20 slot chassis
FMUX20-AC : 100 ~ 240 AC power card
FMUX20-DC24 : 18 ~ 36 DC power card
FMUX20-DC48 : 36 ~ 72 DC power card
Example
: FMUX20-CH20
FMUX20 Slide-in card
FMUX20-NMC :Network Management Card
FRM220-FOM04 : 4E1 +100Mbps Ethernet card
Example
: FRM220-FOM04 w w w. c t c u . c o m
Smart View
Element Management System
(EMS)
Platform server
SV-PLF05 :
5 Client user admission
SV-PLF25 :
25 Client user admission
SV-PLF50 :
50 Client user admission
Device Agents
SV-AGT-50:
50 Device agents
SV-AGT-100:
100 Device agents
SV-AGT-200:
200 Device agents
SV-AGT-500:
500 Device agents
Managed Modules
SV-Fiber :
FMUX20
Example: SV-PLF-05, SV-AGT-50, SV-Fiber
FMUX20
2-102
Table of Contents
Fiber Optic Multiplexer
4 Channel E1/T1, Order wire Plus
100M Ethernet Multiplexer
FOM04
2
FOM04 is a standalone 4xE1/T1 + Fast Ethernet Fiber Multiplexer with 1+1 fiber redundancy. FOM04 provides E1/T1 transmissions transparently along with wire-speed 100Mbps Fast Ethernet simultaneously. The fiber optics utilize industry standard SFP technology that allows a flexible use of Multimode or Single mode lines and enables the support of different wavelengths and distances. The use of bi-directional SFPs maximizes the utilization of the fiber optic line and results in saving line costs. With SNMP and Web-based management in the FMUX20, the Network administrator can monitor, configure and control the activity of each card in the chassis.
●
●
●
●
●
●
●
●
●
Features
Occupies two card slots
4 channels unframed E1/T1
10/100Base-TX Ethernet
Auto MDI/MDIX
Auto-Negotiation or Force mode
Supports flow control
Supports 9K jumbo packets
Supports Link fault pass through (LFP)
One clear channel RS232 up to 250Kbps(Async)
E1/T1 ports
Framing: Unframed (transparent)
Bit Rate: E1:2.048 Mb/s , T1: 1.544Mb/s
Line Code: E1:AMI/HDB3, T1: AMI/B8ZS
Line Impedance:
E1: Unbalanced 75 ohms (BNC)
E1: Balanced 120 ohms (RJ-45)
T1: Balanced 120 ohms (RJ-45)
Receiver sensitivity: Short haul
“Pulse" Amplitude:
Nominal 2.37V+/-10% for 75 ohms
Nominal 3.00V+/-10% for 120 ohms
Nom
“Zero" Amplitude: +/-0.3V
Transmit Frequency Tracking: w/external clock card option
Internal Timing: +/-30 ppm
Jitter Performance: According to ITU-T G.823
Performance monitoring:
According to ITU-T G.821
●
●
●
●
●
●
●
●
1+1 fiber protection, less than 50ms
Supports Digital Diagnostics Monitoring Interface (DDMI)
AIS on signal loss on E1/T1 and fiber port
Loopback test on E1/T1, RS232, fiber ports
Supports Dying Gasp to detect remote power off
Supports local or In-band remote management
Supports Order wire Ear / Microphone port.
Supports On-Line F/W upgrade
Standard: ITU-T G.703, G.704, G.706 and G.732
Interface Connectors: RJ-45, Wire wrap, BNC
RRLB (Request Remote Loop Back)
Test Loops:
LLB (Local Loop Back)
NELB (Near End Loop Back)
RLB (Remote Loop Back)
Ethernet
Interface Type: 10/100Base-TX
Connector: 4xRJ-45
Standard: IEEE 802.3, 802.3u
Duplex modes: full/half
Test: Loop back test
Indication
FX1 Link, FX2 link , E1/T1 Mode/Link/Loopback test , Order wire phone indicator , LAN
Link/Speed.
Power Input
AC, DC Option
Dimensions
155 x 88 x 23mm (D x W x H)
Operating Temperature
0~50°C (Operating) ,-10~20°C (Storage)
Humidity
10~90% non-condensing
Certifications
CE, FCC, RoHS
Managed 4E1/T1 + Fast Ethernet Fiber Optical Multiplexer
STM1
FMUX20-FOM04 inserted in FMUX20
Chassis
Order
Wire
RS232 clear channel
FMUX20
4E1/T1
EMS
PDH Fiber Optic
Multiplexer Platform
1+1 Fiber
Protection
Local
Management
FOM04 FOM04
LAN
Ordering Information
FOM04-DC12 : PDH/Ethernet MUX with AC to DC adapter
FOM04-DC48 : PDH/Ethernet MUX with 48VDC
FOM04-AC : PDH/Ethernet MUX with 100~240VAC
Local
Management
Order
Wire
4E1/T1
LAN
RS232 clear channel
Order
Wire
4E1/T1
LAN
PBX
PBX w w w. c t c u . c o m FOM04
2-104
Table of Contents
Fiber Optic Multiplexer
4 Channel E1/T1, Order wire Plus
100M Ethernet Multiplexer
FMUX04E
FMUX04E is a modular design for 4xE1 + Fast Ethernet multi-service to dual strand fiber PDH multiplexer. FMUX04E provides E1 transmission transparently, pure 100Mbps Fast Ethernet simultaneously. The fiber optic line is based on the SFP technology that allows a flexible use of Multimode or Single mode lines and enable the support of different wavelengths and distances. The use of bi-directional SFPs maximizes the utilization of the fiber optic line and results in saving line costs. The multiplexer is equipped by default with redundant AC and
DC power supplies for redundant operation. With SNMP and Web-based management in the FMUX04E, the Network administrator can monitor, configure and control the activity remotely.
Features
4 channels unframed E1/T1
3 CH 10/100Base-TX Ethernet
Auto MDI/MDIX
Auto-Negotiation or Force mode
Supports flow control
Supports 1552 packets (max)
One clear channel RS232 up to 250Kbps(Async)
1+1 fiber protection, less than 50ms
Supports Digital Diagnostics Monitoring Interface (DDMI)
AIS on signal loss on E1/T1 and fiber port
VLAN function
Loopback test on E1/T1, LAN, RS232, fiber ports
Supports Dying Gasp
Supports local or remote In-band management
Optional SNMP management.
Supports Order wire Ear / Microphone port.
Supports On-Line F/W upgrade
(local or remote) by the SNMP manager.
Two power internal 1AC+1DC
E1/T1 ports
Framing: Unframed (transparent)
Bit Rate: E1:2.048 Mb/s , T1: 1.544Mb/s
Line Code: E1:AMI/HDB3, T1: AMI/B8ZS
Line Impedance:
E1: Unbalanced 75 ohms (BNC)
E1: Balanced 120 ohms (RJ-45)
T1: Balanced 120 ohms (RJ-45)
Receiver sensitivity: Short haul
“Pulse" Amplitude:
Nominal 2.37V+/-10% for 75 ohms
Nominal 3.00V+/-10% for 120 ohms
Nom
“Zero" Amplitude: +/-0.3V
Transmit Frequency Tracking: w/external clock card option
Internal Timing: +/-30 ppm
Jitter Performance: According to ITU-T G.823
Performance monitoring:
According to ITU-T G.821
Customer Premise Equipment (CPE)
Ethernet
Standard: ITU-T G.703, G.704, G.706 and G.732
Interface Connectors: RJ-45, Wire wrap, BNC
Test Loops:
LLB (Local Loop Back)
NELB (Near End Loop Back)
RLB (Remote Loop Back)
RRLB (Request Remote Loop Back)
Interface Type: 10/100Base-TX
Connector: 4xRJ-45
Standard: IEEE 802.3, 802.3u
Duplex modes: full/half
Test: Loop back test
Indication
FX1 Link, FX2 link , E1/T1 Mode/Link/Loopback test , Order wire phone indicator , LAN
Link/Speed.
Power Input
AC : 100~240VAC
DC : 18-75 VDC
Dimensions
236.4x195.2x44mm(DxWxH)
Operating Temperature
0~50°C (Operating) ,-10~20°C (Storage)
Humidity
10~90% non-condensing
Certifications
CE, FCC, RoHS
Customer Premise Equipment (CPE)
PBX
Order
Wire
Order
Wire
4E1/T1 4E1
LAN
LAN
Fast Ethernet
RS232 clear channel NMS
NMS
2-105
Ordering Information
FMUX04E : 4 Channel E1/T1, Order wire Plus 100M Ethernet Multiplexer
FMUX04E-AC: 4 Channel E1/T1, Order wire Plus 100M Ethernet Multiplexer with AC power
FMUX04E-DC: 4 Channel E1/T1, Order wire Plus 100M Ethernet Multiplexer with DC power
FMUX04E www.ctcu.com
Table of Contents Fiber Optic Multiplexer
4 Channel E1/ T1 Multiplexer
FMUX04
The FMUX04 is a 1U half 19" stand-alone or rack mountable point-to-point multiplexer for 4*E1 or 4*T1 (selectable) transmissions over a single fiber optic link. Its half-rack format makes it ideal for low cost multiplexing applications that require up to 4-channel. All channels provide completely transparent transmission of E1 or T1 regardless of frame mode, clock source or timeslot assignment. Available in either AC or DC models, the AC supplies operate from 100~240VAC while DC supplies operate from 18~72VDC. A wide range of transceiver selection provides fiber connection with SC, FC or ST type connectors in multimode or single mode and at distance from 2 to 120km as well as BiDi (single fiber) at distances of 20, 40, 60, or 80km. Additional options include "Order Wire" phone connection (FXS port) and a SNMP management.
●
●
●
●
●
●
●
●
●
Features
1U stand-alone unit
Channel service setting and remote loop-back setting via front panel DIP switch or serial console
Far End Fault (FEF) on fiber link, selectable
On-line Bit Error Rate monitor feature with four error-rate classes
Dual color LEDs indicators
Optional dedicated Order Wire phone port (FXS, RJ-11 port)
Console port and one alarm relay
Optional SNMP management, Telnet, and Web Based local and remote configuration
System BER 10 -11
Optical Interface
Electrical Interface :
Standard
Indication
Power input
Power Consumption
Dimensions
Connector : 1x9 (SC, ST, FC)
Data rate : 38Mbps
Bit Error Rate : Less than 10 -11
Fiber : MM 62.2/125μm, 50/125μm.
SM 9/125μm
Distance: MM 2km, SM 15/30/50/80/120km,
WDM 20/40/60/80km
Wavelength :
Console :
1310, 1550nm
RS232 (DB9F) Async
SNMP :
Order wire :
RJ45
RJ11
E1 : BNC 75 Ω, RJ45 120 Ω
T1 RJ45 100 Ω, 100 metersΩ
E1:ITU-T, T1:ITU-T, AT&T, ANSI
PWR, Alarm, Far End /Near End Error,
System failure, E1/T1 status
AC : 100 ~240V
DC24 : 18 ~ 36V, DC48 : 36 ~ 72V
< 20W
235 x 195 x 45mm(DxWxH)
Weight
Temperature
Humidity
Certification
MTBF
850g
0~50°C (Operating) ,0~70°C (Storage)
10~90% non-condensing
CE, FCC, RoHS
57350 hours
2
Customer Premise Equipment (CPE)
Order
Wire
4E1
FMUX04
Customer Premise Equipment (CPE)
PBX
Order
Wire
4E1/T1
FMUX04
NMS
NMS
Ordering Information
FMUX04 : 4 Channel E1/T1 Multiplexer
FMUX04 2-106
Table of Contents
Fiber Optic Multiplexer
1U 4-Slot STM-1
Add-Drop Multiplexer
SDH01A
The SDH01A, STM-1 Based Multi-Service Provisioning
Platform, is an advanced compact Add Drop Multiplexer which can transmit up to 63 E1 and/or data service such as V.35 and
Ethernet via an SMT-1 ring. The optical interface complies with international telecommunication standards, such as ITU-T
G.655, G.652, and G.653. By utilizing a modular design for aggregate and low speed tributaries, the SDH01A can meet your network demands with a flexible combination of services at a lower cost. All of the pluggable modules are designed to be hot swapped without any interruption to traffic when plugging in or out. In addition to the E1 tributaries, other data interfaces are also provided for data communications such as V.35 and
10/100M Ethernet. Users can select any combination of modules according to their requirements. With its full function and multi-access capability, the SDH01A is your best choice for optical SDH networks.
●
Features
Stand-alone and rack-mount in 19 or 23 inch EIA rack.
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Up to 32 E1 (4, 8, 12, 16 & 32)
Flexible ADM (add/drop multiplexer) with 63 available VC12 resources
Up to 4 tributary cards per unit.
Every module hot swappable
Backup configurations in flash for system restart or power failure.
Various services, such as E1, V.35 and 10/100M Ethernet
Ethernet traffic is encapsulated and transported over SDH using
Generic Framing Procedure (GFP) & Virtual Concatenation (VCAT)
E1 transparent transmission with HDB3 or AMI line coding
EoS (Ethernet over SDH) for E-LAN. Supports Ethernet traffic in all nodes of rings
Single-ended network management
1+1 APS for optical line and module (optical redundancy)
Three timing synchronization modes
Alarm relays
Alarm and performance monitoring
Administration security with login by username and password assigned by supervisor
Menu-driven and SNMP management interfaces
Local and remote loop back functions for optical and E1 I/Fs
Dual power AC + DC
Optical Interface
Electrical Interface
Connector
Data rate
Fiber
Distance
Wavelength
Console
SNMP, LAN
Alarm
1x9 (SC, FC)
155.52Mpbs (STM-1)
SM 9/125μm
SM 30/60/120km, WDM 60km
1310nm, 1550nm
D-type 9-pin female
RJ45
D-type 9-pin male
Standard
Indication
Power
Power Consumption
Dimensions
Weight
Temperature
Humidity
Certification
MTBF
STM1: ITU-T G.707, G.841, G.783, G.803, G.652
E1: ITU-T G.703 G.704, G.706, G.732, G.823
T1: ITU-T G.703 G.704, G.706, G.733
Ethernet: ITU-T G.7041 GFP-F, G.707 VCAT,
IEEE802.3x, 802.1p, 802.1q, 802.3ad,
802.1w, 802.1d
V35: ITU-T V.35, ITU-T G703
PWR, WK, FLT-fault, Alarm, ACO, RDI, LBK,
Channels, Ethernet
AC : 90 ~ 264V, DC24 : -36 ~ -72V
< 15W
312 x 440 x 44mm (D x W x H)
3.6 kg
0 ~ 50°C (Operating) ,-10 ~ 70°C (Storage)
10 ~ 90% non-condensing
CE, FCC, RoHS
50,000 hours
Managed STM -1 Add Drop Multiplexer
LAN
SDH01A
Fiber Ring
2-107 SDH01A
Ethernet
E1/T1
PBX www.ctcu.com
Table of Contents Fiber Optic Multiplexer
Specifications
Ethernet Tributary Interface (QSW)
Data rate :
4CHx10/100Mbps with auto negotiation
Compliance : ITU-T G.7041 GFP-F, G.707 VCAT
IEEE 802.3x, 802.1p, 802.1q (Q-in-Q),802.3ad
Mode : L2 Switch 100Mbps throughput
Connector : RJ-45
V.35 Tributary Interface (QV35)
Data rate : 4CHx Nx64Kbps (N=1~32)
Compliance : ITU-T V.35, ITU-T G.703
Clock Source : External, Internal and Recovery
Control Signal : DSR, CTS, DCD, RL, LL …
Test Loops : Local/remote line/terminal/V.54 loopback
Connector : DB44 connector (DB44 to M34 converter cable)
E1 Tributary Interface (QE1B)
Bit rate : 4CHx2.048Mbps±50ppm
Compliance : ITU-T G.703, G.704, G.706,
G.732, G.823
Impedance (connector) : 75Ω(BNC)
Line code : HDB3 / AMI
E3 /DS3 Tributary Interface (ET3)
Bit rate : 34.368 / 44.736 Mbps±20ppm
Compliance : ITU-T G.703, G.823, G.824
Impedance(connector) : 75Ω(BNC)
Line code : HDB3 / B3ZS
Software selectable E3/DS3 mode
8E1/ T1 Tributary Interface (8ET)
Bit rate :
8CHx2.048Mbps±50ppm /1.544Mbps±50ppm
Impedance(connector) :
120/100Ω software selective (wire-wrap)
Management Interface
Protocol : VT-100 ANSI/ Telnet and SNMP (EMS)
Craft interface : RS232 Asyc. (EIA561)
Telnet//SNMP/httpd : 10/100 BaseT (RFC 1406)
LCD : 2 X 16 LCD display with key control
Operation Requirement
Operating temperature : 0~55°C
Humidity : 0% ~ 100% (100% at 30°C)
MTBF: > 50000 hours
EMI : CISPR 22 class A
ESD : IEC-61000-4-2 level 2
Lightening and Surge : IEC-61000-4-5 class3
Dimension & Weight
(WxDxH) : 442 x 312 x 44mm 1U, 19" rack mount/ wall mount/ standalone
Weight : 3.7kg
Power Consumption
27W in full load
2 w w w. c t c u . c o m
Ordering Information
Chassis
SDH01A-AD 1U 19", STM-1 ADM chassis with AC+DC power
Interface modules
4E1B 4 * E1 G.703 interface card BNC
8E1R 8 * E1 G.703 interface card 120 ohm RJ48
4E1R 4 * E1 G.703 interface card 120 ohm RJ48
4V35 4 * V35 interface card
4SW 4 * 10/100 Base Ethernet Switch
ET3 E3/DS3 interface card
Example : SDH01A-CH-AD
Example
: SDH01A-4V35
SDH01A 2-108
Table of Contents
Fiber Optic Multiplexer
New
STM-1/4 Add-Drop Multiplexer
SDH04A
The SDH04A is a compact NG-SDH equipment which supports STM-1/4 ADM and offers various tributary interfaces like E1/T1, V.35,
FE/GbE, E3/ T3…etc to provide any service in any slot. SDH04A is suitable for the applications of GSM/UMTS base station radio access networks (RAN) / MSAN and wireless backhaul. The SFP cage design in SDH04A offers the plug-and-play flexibility to change fiber modules for different bit rate and higher availability to use off-the-shelf fiber modules . Although SDH04A is a 1U standard form factor makes CTC
SDH04A easy to fit in any 19” or 23” chassis and outdoor cabinet; Although SDH04A is a compact NG-SDH box, it also has similar flexibility of shelf-type SDH equipment, such as hot-swappable tributary cards / fiber modules / power modules and 1+1 load-sharing redundant power design. In order to supply reliable networks to carry more upcoming broadband services from wireless / HSDPA base stations to central office, CTC SDH04A provides carry-grade Ethernet (E-Line) bundled with L2 functions to totally control QoS between end to end. SDH04A also can work with CTC SDH01A series to have Ethernet private LAN (E-LAN) service in ring topology.
Features
●
SDH04A provides multiple service solutions with standard
STM-1/4 interfaces (SDH ADM/TM).
●
Multiple hot-swappable tributary modules in any combination:
4-channels E1 card (QE1R/B)
8-channels E1/T1 card (8ET)
8-channels E1 card (8E1R)
4-ports Ethernet switch over SDH interface card (QSW)
4-ports Gigabit Ethernet switch card (GbE)
4-ports V.35 Data communication Interface card (QV35)
Single port E3/T3 interface card (ET3)
●
4 slots to support combinations of traffics in a 1U-height box
●
Ethernet traffic is encapsulated and transported over SDH
using Generic Framing Procedure (GFP) & Virtual
Concatenation (VCAT)
●
Hot swappable fiber optical module in SFP with optional 1+1
automatic protection switching (APS) for optical links.
●
Automatic Laser Shutdown (ALS) based on ITU-T G.958/G.664.
●
Data Communication Channel for remote control and online
remote upgrade.
●
Various network management interfaces: RS-232/ Ethernet/ LCD
●
1+1 Redundant AC/DC power modules with load sharing.
●
Cross connect for TDM traffic (E1 & V.35)
●
EMS tool for SDH04A series (GMS)
●
DHCP Client/Telnet/httpd for NMS port
●
Keypad Lock/ Password for LCD security
2-109
IP
Network
NxE1
3G Radio Network
Controllers
SDH
NxE1
Ethernet
DDN
SDH
F
(15TS) (8TS) (8TS)
1xE1
STM-4/16
SDH04A
CO
PBX
NxE1
STM-8
Ethernet
SDH04A
Splitter
STM-8
RT
NxE1
WiMax
ONU
F
15TS=960kbits V.35
F
8TS=512kbits V.35
F
8TS V.35
DTE
DTE
DTE
SDH04A www.ctcu.com
Table of Contents Fiber Optic Multiplexer
Specifications
Ethernet Tributary Interface (QSW)
Data rate :
4CHx10/100Mbps with auto negotiation
Compliance : ITU-T G.7041 GFP-F, G.707 VCAT
IEEE 802.3x, 802.1p, 802.1q (Q-in-Q),802.3ad
Mode : L2 Switch 100Mbps throughput
Connector : RJ-45
V.35 Tributary Interface (QV35)
Data rate : 4CHx Nx64Kbps (N=1~32)
Compliance : ITU-T V.35, ITU-T G.703
Clock Source : External, Internal and Recovery
Control Signal : DSR, CTS, DCD, RL, LL …
Test Loops : Local/remote line/terminal/V.54 loopback
Connector : DB44 connector (DB44 to M34 converter cable)
E1 Tributary Interface (QE1B)
Bit rate : 4CHx2.048Mbps±50ppm
Compliance : ITU-T G.703, G.704, G.706,
G.732, G.823
Impedance (connector) : 75Ω(BNC)
Line code : HDB3 / AMI
AC Power Card
Input Voltage : AC90V ~ 260V
Input Frequency : 47 ~ 63Hz
Power : 27W Max
DC Power Card
Input Voltage : DC-36V ~ -72V
Power : 27W Max
E3 /DS3 Tributary Interface (ET3)
Bit rate :
Bit rate :
34.368 / 44.736 Mbps±20ppm
Compliance :
Impedance(connector) :
Line code :
ITU-T G.703, G.823, G.824
HDB3 / B3ZS
Impedance(connector) :
75Ω(BNC)
Software selectable E3/DS3 mode
8E1/ T1 Tributary Interface (8ET)
8CHx2.048Mbps±50ppm /1.544Mbps±50ppm
120/100Ω software selective (wire-wrap)
Gigabit Ethernet interface (GbE)
Connector : 2xRJ45 + 2x SFP
Compliance : 802.3z, 802.3x, 802.1p,802.3u,
802.3, G.7041 GFP-F Up to 1Gbps throughput, 802.1Q VLAN support for the full 4096
VLAN ID Up to 8K MAC address, Port trunking, Traffic rate control, loopback test
Management Interface
Protocol : VT-100 ANSI/ Telnet and SNMP (EMS)
Craft interface : RS232 Asyc. (EIA561)
Telnet//SNMP/httpd : 10/100 BaseT (RFC 1406)
LCD : 2 X 16 LCD display with key control
Operation Requirement
Operating temperature : 0~55°C
Humidity : 0% ~ 100% (100% at 30°C)
MTBF: > 50000 hours
EMI : CISPR 22 class A
ESD : IEC-61000-4-2 level 2
Lightening and Surge : IEC-61000-4-5 class3
Dimension & Weight
(WxDxH) : 442 x 312 x 44mm 1U, 19" rack mount/ wall mount/ standalone
Weight : 3.7kg
Power Consumption
27W in full load
2 w w w. c t c u . c o m
Ordering Information
Chassis
SDH04A-CH 1U 19", STM4/1 ADM chassis without power module
Power
SDH04A-DC SDH04A Chassis DC power module
SDH04A-AC SDH04A Chassis AC power module
Interface modules
4E1B 4 * E1 G.703 interface card BNC
8E1B 8 * E1 G.703 interface card 75 ohm RJ48 with 8 x 1ch RJ48 to BNC
8E1R 8 * E1 G.703 interface card 120 ohm RJ48
8T1/E1W 8 * T1/E1 G.703 interface card Wire-Wrap
4V35 4 * V35 interface card with 2 x 2ch M34 cables
4SW Ethernet over SDH card, 4 * 10/100 BaseTx RJ45
ET3 E3/DS3 interface card
4GE 4 ports Giga switch tributary card
SDH04A 2-110
Fiber Optic Multiplexer
Table of Contents
STM4/16 NG-SDH ADM Concentrator
SDH16A-RM
CTC mini MSTP SDH04/16 is a new generation carrier-grade STM 4/16 integrated next-generation SDH functionality and TDM aggregation with advanced, Layer 2 packet-switching features for the migration to multiservice networks. The interfaces of SDH16A-RM included STM1/4,
E1/T1, E3/DS3, V.35 and Ethernet allow service providers to support new broadband services, such as Ethernet Services (E-Line, E-LAN),
PON, and 3G mobile services, as well as transport-oriented services such as TDM private lines, over a single aggregation multiservice platform.
It is mainly applied in the access layer of the MAN (Metropolitan Area Network) and provides complete solutions for the evolution of the existing
SDH equipment to intelligent optical network equipment with powerful cross-connect capacity (not only E1 level, but also nx64K grooming) as well as network protection. CTC SDH16A-RM mini MSTP can be easily integrated into any other service nodes, such as 2G/3G mobile base stations, DSLAM, DLC or voice access remote node, etc., to provide a total solution. SDH16A-RM’s flexible design is allowed to support
STM16 by perfect smooth firmware upgrade to meet plenty of bandwidth required in the future and significantly reduces deployment cost.
Features
● SDH16A-RM provides multiple service solutions with standard
STM4/16 ADM interfaces.
● Supports multiple hot-swappable tributary modules:
4-channels E1 card
8-channels E1/T1 card
4-ports V.35 Data communication Interface card
Single port E3/T3 interface card
4-ports Gigabit Ethernet switch card
4-ports Ethernet switch over SDH interface card
Standard SFP STM1/STM4/STM8 for fiber tributary interfaces with 1+1 protection
● 8 SFP cages for tributary/ aggregation fiber modules & 8 slots to support combinations of TDM/Ethernet traffics in a 3.5U-height shelf
● All Front Access
● Stratum4/4E clock accuracy supported, stratum3 is optional
● 3 timing sources: free run/ fiber lines /external
● Hot swappable SFP fiber optical modules with 1+1 automatic protection switching (APS)
● Automatic Laser Shutdown (ALS) based on ITU-T G.958/G.664.
● 1+1 Redundant AC/DC power modules provided with load-sharing
● Ethernet traffic is encapsulated and transported over SDH using Generic
Framing Procedure (GFP) & Virtual Concatenation (VCAT)
● Built-in V.54 / PRBS …etc tests
● Powerful cross connect & 64K grooming supported
● Data Communication Channel for remote control and online remote upgrade.
● Various network management interfaces: RS-232/ Ethernet/ LCD
● DHCP Client/Telnet for NMS port
● Web-based management
IP
Network
(CO)
SDH16A-RM
E3/T3
Micro wave
Radio
(RT1)
SDH16A-RM
STM-1/4/8
E3/T3
MX3
NxE1
NxE1
PBX
NxE1
3G Radio Network
Controllers
(RT2)
SDH16A-RM
STM-1/4/8
GbE
NxE1
HSDPA
WiMax
2-111 SDH16A-RM www.ctcu.com
Table of Contents Fiber Optic Multiplexer
Ethernet Tributary Interface (QSW)
Data rate :
4CHx10/100Mbps with auto negotiation
Compliance : ITU-T G.7041 GFP-F, G.707 VCAT
IEEE 802.3x, 802.1p, 802.1q (Q-in-Q),802.3ad
Mode : L2 Switch 100Mbps throughput
Connector : RJ-45
V.35 Tributary Interface (QV35)
Data rate : 4CHx Nx64Kbps (N=1~32)
Compliance : ITU-T V.35, ITU-T G.703
Clock Source : External, Internal and Recovery
Control Signal : DSR, CTS, DCD, RL, LL …
Test Loops : Local/remote line/terminal/V.54 loopback
Connector : DB44 connector (DB44 to M34 converter cable)
E1 Tributary Interface (QE1B)
Bit rate : 4CHx2.048Mbps±50ppm
Compliance : ITU-T G.703, G.704, G.706,
G.732, G.823
Impedance (connector) : 75Ω(BNC)
Line code : HDB3 / AMI
AC Power Card
Input Voltage : AC90V ~ 260V
Input Frequency : 47 ~ 63Hz
Power : 27W Max
DC Power Card
Input Voltage : DC-36V ~ -72V
Power : 27W Max
E3 /DS3 Tributary Interface (ET3)
Bit rate : 34.368 / 44.736 Mbps±20ppm
Compliance : ITU-T G.703, G.823, G.824
Impedance(connector) : 75Ω(BNC)
Line code : HDB3 / B3ZS
Software selectable E3/DS3 mode
8E1/ T1 Tributary Interface (8ET)
Bit rate :
8CHx2.048Mbps±50ppm /1.544Mbps±50ppm
Impedance(connector) :
120/100Ω software selective (wire-wrap)
Gigabit Ethernet interface (GbE)
Connector : 2xRJ45 + 2x SFP
Compliance : 802.3z, 802.3x, 802.1p,802.3u,
802.3, G.7041 GFP-F Up to 1Gbps throughput, 802.1Q VLAN support for the full 4096
VLAN ID Up to 8K MAC address, Port trunking, Traffic rate control, loopback test
Management Interface
Protocol : VT-100 ANSI/ Telnet and SNMP (EMS)
Craft interface : RS232 Asyc. (EIA561)
Telnet//SNMP/httpd : 10/100 BaseT (RFC 1406)
LCD : 2 X 16 LCD display with key control
Operation Requirement
Operating temperature : 0~55°C
Humidity : 0% ~ 100% (100% at 30°C)
MTBF: > 50000 hours
EMI : CISPR 22 class A
ESD : IEC-61000-4-2 level 2
Lightening and Surge : IEC-61000-4-5 class3
Dimension & Weight
(WxDxH) : 442 x 312 x 44mm 1U, 19" rack mount/ wall mount/ standalone
Weight : 3.7kg
Power Consumption
27W in full load
2
Ordering Information
Chassis
SDH16A-RM : 3.5U 19” 8 slot STM4/16 NG-SDH Concentrator
SDH16A-AC : 60W AC power module for SDH16A-RM
SDH16A-DC : 60W DC power module for SDH16A-RM
Interface modules
4E1B 4 * E1 G.703 interface card BNC
8E1B 8 * E1 G.703 interface card 75 ohm RJ48 with 8 x 1ch RJ48 to BNC cables
8E1R 8 * E1 G.703 interface card 120 ohm RJ48
8T1/E1W 8 * T1/E1 G.703 interface card Wire-Wrap
4V35 4 * V35 interface card with 2 x 2ch M34 cables
4SW
ET3
4GE
Ethernet over SDH card, 4 * 10/100 BaseTx RJ45
E3/DS3 interface card
4 ports Giga switch tributary card w w w. c t c u . c o m SDH16A-RM 2-112
over
5
Table of Contents
E1 CSU/DSU Concentrator
Managed G.703 E1 CSU/DSU Concentrator
ERM01
The ERM01 is a 4U 19(23)" concentrator rack type E1
DSU/CSU for Fractional and Unframed G.703 E1 Access for central office installations. There are 13 slots available for hot swappable G.703 E1 cards. An optional SNMP card can be installed into the last slot for configuration and management, leaving 12 slots available for G.703 cards. The SNMP card provides both local control via an RS-232 serial console port and remote IP management using Telnet or industry standard SNMP protocol. Each E1 card may be linked to a remote E1/FE1 stand-alone Access Unit for various LAN, Data, or hosts over E1 network services. The ERM01 accommodates an optional second hot swappable shared power supply module which may derive power from AC (90-250) or DC (-48V) power sources. On the rear panel, combinations of BNC, RJ-45 and wire-wrap terminals are utilized for E1 Line interface connections. Adapter cables are used to convert the HDB26F DCE data ports to V.35,
RS-530, RS-449, X.21 or 10/100 Base Ethernet depending on the installed card.
●
●
●
●
●
●
●
●
●
Features
Managed chassis (Optional) with DSU/CSU blades
Supports Fractional and Unframed E1 with EOC control
Hot swappable blades and power modules
Interface Cards for V.35, X.21, RS-530, RS-449, RS-232,
Ethernet Bridge and Router
I/O connectors all on rear panel
Multiple clock source selection (Internal or External: E1 recovery, DTE or DCE)
Built-in BERT with V.54 diagnostic capabilities for performing local and remote loopback
Supports local serial Console, remote Telnet and SNMP
Supported by SmartView EMS
Ordering Information
ERM01 Chassis
ERM01-AC-CH :
ERM01-DC-CH :
ERM01R-AC-CH :
ERM01R-DC-CH :
ERM01B-AC-CH :
ERM01B-DC-CH :
AC power type chassis w/ E1 BNC, RJ45
DC power type chassis w/ E1 BNC, RJ45
AC power type chassis w/ E1 RJ45
DC power type chassis w/ E1 RJ45
AC power type chassis w/ E1 BNC
DC power type chassis w/ E1 BNC
Power Card
ERM01-AC :
ERM01-DC :
AC Power card ( 100 ~ 240 VAC )
48VDC, 72VDC Power card
G.703 E1
Frame format
Bit rate
Line Code
Receiving level
Line Impedance
Jitter Performance
Pulse amplitude
Connector
Unframed/ Framed, CCS(PCM31)/
CAS(PCM30)/ CRC4 on/off
2.048Mbps±50 ppm
AMI/ HDB3
0 ~ -43dB
75 ohm(BNC) / 120 ohm (RJ-45)
According to ITU-T G.823
Nominal 2.37V ±10% for 75ohm,
Nominal 3.00V ±10% for 120ohm
Zero amplitude ± 0.1V
BNC for unbalanced and RJ-45 for balanced
Transmit frequency tracking
Return loss
Internal timing ±30 ppm
Loopback timing ±50 ppm
External timing ±100 ppm
12dB for 51 ~ 102KHz
18dB for 102 ~ 2048KHz
14dB for 2048~ 3072KHz
User Data Channel
Interface Types
Connector
Line code
Data Rate
RS-530/RS-449/RS-232,X.21/V.35,
10/100Base-T Ethernet Bridge & Router
High density DB26 Female
NRZ (except bridge)
N x 56Kbps or N x 64Kbps, Where N equal 1 to 32
Time slot allocation
Control signals
Loopback
Clock modes
Standards
User defined
CTS constantly On,
DSR constantly ON, except during test loops,
DCD constantly ON or follows RTS, except during signal loss
Line loopback, Payload loopback, Local loopback,
DTE loopback
Clock mode 0
Rx & Tx clocks (recovered) to (DCE1) sync DTE
Clock mode 1
Rx & Tx clocks (internal oscillator) to(DCE2) sync DTE
Clock mode 2
Rx clock to sync device,(DTE1) Tx clock from sync device
Clock mode 3
Rx & Tx clocks from (DTE2) sync DCE (from ETC and ERC pin)
Clock mode 4
Rx & Tx clocks from sync DCE (DTE3) (all from ETC pin)
ITU-T G.703, G.704, G.706 and G.732 and ETSI ETS 300 420
Power Input
Power Consumption
Dimensions
Weight
Temperature
Humidity
Certification
MTBF
AC: 100~240VAC
DC: -42~-55
80W
Chassis : 285 x 438 x 180mm (D x W x H)
Line card: 260 x 22 x 180mm (D x W x H)
6.6kg
0~50°C (Operating) ,-10~70°C (Storage)
10~90% non-condensing
CE, FCC, RoHS
57,000 hrs (25°C)
5-1
ERM01 www.ctcu.com
Table of Contents
E1 CSU/DSU Concentrator
ERM01 overview
Secondary power
Main power
Fractional E1 with
BNC Terminal Block, or RJ-45 interface connector
SNMP Card
E1 unbalanced BNCs
13 line cards can be installed into the rack
12 when the SNMP optional card is installed
Alarm Relay Contacts
Main Switch
HDB26F Data Port IEC AC Mains Input
BNC+Data port mode chassis back view
E1 CSU/ DSU Slide-in Card
Network Management Card
ERM01-SNMP
Ethernet Router Card
Unframed/ Framed E1 to 10/100Base-TX
ERM01-FE1/ET100R ERM01-E1U/ET100R
Ethernet Bridge Card
Unframed/ Framed E1 to 10/100Base-TX
ERM01-FE1/ET100 ERM01-E1U/ET100
E1 to Data Card
Unframed/ Framed E1 to Data Card
ERM01-FE1/V35 ERM01-E1U/V35
ERM01-FE1/RS530
ERM01-FE1/RS449
ERM01-FE1/X21
ERM01-FE1/RS422
ERM01-E1U/RS530
ERM01-E1U/RS449
ERM01-E1U/X21
ERM01-E1U/RS422
5
100 B as e-T X
R S -449
N*64K bps
X.21
V 35
E R M01
E1
Network
E R M01
V 35
N*64K bps
X.21
R S - 449
100 B as e-T X
NMS NMS
Ordering Information
ERM01 Slide-in card
ERM01-SNMP : SNMP card with RS-232 and Ethernet 10/100Base-TX
Fractional Interface cards
ERM01-FE1/ET100 :
ERM01-FE1/ET100R :
ERM01-FE1/V35 :
ERM01-FE1/RS530 :
ERM01-FE1/RS449 :
ERM01-FE1/X21 :
ERM01-FE1/RS422 :
FE1(N64) to 10/100Base-T/Tx Ethernet Bridge
FE1(N64) to 10/100Base-T/Tx Ethernet Routing
FE1(N64) to V.35 with cable adapter
FE1(N64) to RS530 with cable adapter
FE1(N64) to RS449 with cable adapter
FE1(N64) to X.21 with cable adapter
FE1(N64) to RS422 with cable adapter
Unframed Interface cards
ERM01-E1U/ET100:
ERM01-E1U/ET100R:
ERM01-E1U/V35:
ERM01-E1U/RS530:
ERM01-E1U/RS449:
ERM01-E1U/X21:
ERM01-E1U/RS422:
Unframed E1 to 10/100Base-T/Tx Ethernet Bridge
Unframed E1 to 10/100Base-T/Tx Ethernet Router
Unframed E1 to V.35 with cable adapter
Unframed E1 to RS530 with cable adapter
Unframed E1 to RS449 with cable adapter
Unframed E1 to X21 with cable adapter
Unframed E1 to RS422 with cable adapter
Smart View Element Management System (EMS)
Platform server
SV-PLF05 :
5 Client user admission
SV-PLF25 :
25 Client user admission
SV-PLF50 :
50 Client user admission
Device Agents
SV-AGT-50:
50 Device agents
SV-AGT-100:
SV-AGT-200:
100 Device agents
200 Device agents
SV-AGT-500:
500 Device agents
Example: SV-PLF-05, SV-AGT-50, SV-PDH
Managed Modules
SV-PDH :
ERM01 w w w. c t c u . c o m ERM01
5-2
Table of Contents
E1 CSU/ DSU Slide-in Card
Fractional
Fractional E1 to 10/100Base-TX
Ethernet Router Card
ERM0 1 -FE1/ET100R
The ERM01-FE1/ET100R Router Card is a single slot card that can be installed in any available slot to provide IP over E1 transmission. The router engine uses an embedded system which can be configured and controlled from a serial port, Telnet or Web based user interface. It supports industry standard encapsulations of PPP and HDLC as well as proprietary header for Cisco router's HDLC.
●
Features
Ethernet port IP Address/subnet mask
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
WAN port IP Address/subnet mask
Router Name / Password
RS-232 Console Port Management
Web/Telnet Management
WAN port IP address/subnet mask
DHCP server/client
NAT Function
Virtual Server Mapping
SNMP MIB-2 supported
Supports VPN pass through
Forwarding IP multicast support
DNS proxy server
SNTP supported
Simple Statistical
Ping and Trace route
Static Routing Setup
Routing Table (manually set up to 32 entries minimum)
Dynamic Routing RIP I & II, Send or Receive on Ethernet or WAN
PPP, HDLC and Cisco HDLC WAN protocol encapsulatoin
Flash Upgrade (via TFTP)
Hardware
Connection
WAN Speed
LAN Speed
Function
Protocols
Security
LED
Samsung ARM9 integrated communications
166MHz processor, 8MB Flash, and 32MB pipeline RAM for code, data and buffers
1 x Ethernet LAN port (10/100)
Synchronous Port N56/N64 up to 2048Kbps
Ethernet LAN port 10/100 Mbps
Proxy Routing, IP Routing, Static Routing,
Dynamic Routing, DHCP Client/ DHCP
Server, IP Mapping, Packet Filtering
PPP, NAT, RIP 1/2, TCP/IP
PAP/CHAP, NAT, Filter
Link/ACT : On=link ; Flash=Activity
100 : On=100Base ; Off=10Base
5
Fractional E1 to 10/100Base-TX
Ethernet Bridge Card
ERM0 1 -FE 1 /ET 1 00
The ERM01-FE1/ET100 Bridge Card is a single slot card that can be installed in any available slot to provide Ethernet over E1 transmission. The bridge engine uses an ASIC design for wire speed performance and supports industry standard HDLC encapsulation. The ERM01-E1U-ET100 bridge is an economical solution for LAN to LAN applications over framed or Unframed E1 transport.
Features
●
●
●
●
●
●
●
●
●
●
High performance bridge for 10Base-T or 100Base-TX Ethernet extension.
Auto-MDI/MDIX detects and corrects crossed cable.
Ethernet LAN Interface on RJ-45 connector.
Transparent half / Full duplex support on WAN / LAN interface.
Automatic LAN table learning and aging.
IEEE 802.3x flow control.
Filter mode (pure bridge) or repeater mode selectable
Provides Ethernet over E1 economically
No IP address settings required
Simple DIP switch setting to control filtering, packet buffer and
Ethernet auto/forced mode
Bridge
LAN
General
LAN Table: 256 MAC address with 5 minute automatic aging
Filtering and Forwarding : wire speed
Packet size; 64~1522 Bytes
Buffer : 340 frames
Delay : 1 frame
Standard : compliant to IEEE802.3 /803.2u
Data rate : 10Base-T / 100Base-TX, Full or Half
Duplex
Connector : RJ45
IP bridging over G.703 E1
ISO standard HDLC encapsulation
WAN Speed: Nx64 (where N=1 to 31) for Fractional
E12048Kbps for Unframed E1 w w w. c t c u . c o m ERM01-FE1/ET100R
5-4
Table of Contents
E1 CSU/ DSU Slide-in Card
Fractional E1 to Data Card
ERM0 1 -FE 1 /Data
(transparent) and with cables that terminate in the appropriate user interface for DCE. Simple DIP Switch settings provide all the control for E1 and Dataport settings. When the ERM01 is equipped with optional SNMP, centralized management can configure and monitor the card and performance without manual DIP setting.
●
●
●
●
●
Features
HS (up to 2Mb/s) Serial interface card for serial transport over G.703 E1.
DIP switch or SNMP managed (Optional)
Hot swappable without effecting any other line card
Front panel pushbuttons to activate loop testing with integral 511 pattern BERT.
LED status indicators for E1 Signal, Sync and Dataport TD, RD, and CD.
●
●
●
●
Specifications
Compliant with ITU-T standards for V.35, RS-530, X.21 and V.36
Synchronous transmission at Nx64 data rate (2.048M for Unframed)
Line code: NRZ
Control Signals: CTS always ON
Cable Adapter :
HDB26M to MB34F for V.35
HDB26M to DB25F for RS-530
HDB26M to DB37F for RS-449(V.36)
HDB26M to DB15F for X.21
Ordering Information
FE1/ET100 :
FE1/ET100R :
FE1/V35 :
FE1/RS530 :
FE1/RS449 :
FE1/X21 :
FE1/RS422 :
FE1(N64) to 10/100Base-T/Tx Ethernet Bridge
FE1(N64) to 10/100Base-T/Tx Ethernet Routing
FE1(N64) to V.35 with cable adapter
FE1(N64) to RS530 with cable adapter
FE1(N64) to RS449 with cable adapter
FE1(N64) to X.21 with cable adapter
FE1(N64) to RS422 with cable adapter
Unframed
Unframed E1 to 10/100Base-TX
Ethernet Router Card
ERM0 1 -E 1 U/ET 1 00R
5-5
The ERM01-E1U/ET100R Router Card is a single slot card that can be installed in any available slot to provide IP over E1 transmission. The router engine uses an embedded system which can be configured and controlled from a serial port, Telnet or Web based user interface. It supports industry standard encapsulations of PPP and HDLC as well as proprietary header for Cisco router's HDLC.
●
Features
Ethernet port IP Address/subnet mask
● WAN port IP Address/subnet mask
● Router Name / Password
● RS-232 Console Port Management
● Web/Telnet Management
● WAN port IP address/subnet mask
● DHCP server/client
● NAT Function
● Virtual Server Mapping
● SNMP MIB-2 supported
● Supports VPN pass through
● Forwarding IP multicast support
● DNS proxy server
● SNTP supported
● Simple Statistical
● Ping and Trace route
● Static Routing Setup
● Routing Table (manually set up to 32 entries minimum)
● Dynamic Routing RIP I & II, Send or Receive on Ethernet or WAN
● PPP, HDLC and Cisco HDLC WAN protocol encapsulatoin
● Flash Upgrade (via TFTP)
Hardware
Connection
WAN Speed
LAN Speed
Function
Protocols
Security
LED
Samsung ARM9 integrated communications
166MHz processor, 8MB Flash, and 32MB pipeline RAM for code, data and buffers
1 x Ethernet LAN port (10/100)
Synchronous Port 2048Kbps
Ethernet LAN port 10/100 Mbps
Proxy Routing, IP Routing, Static Routing,
Dynamic Routing, DHCP Client/ DHCP
Server, IP Mapping, Packet Filtering
PPP, NAT, RIP 1/2, TCP/IP
PAP/CHAP, NAT, Filter
Link/ACT : On=link ; Flash=Activity
100 : On=100Base ; Off=10Base
ERM01-FE1/Data www.ctcu.com
Table of Contents
E1 CSU/ DSU Slide-in Card
Unframed E1 to 10/100Base-TX
Ethernet Bridge Card
ERM0 1 -E 1 U/ET 1 00
Card is a single slot card that can be installed in any available slot to provide Ethernet over E1 tion. The ERM01-E1U-ET100 bridge is an economical solution for LAN to LAN applications over an Unframed E1 transport.
Features
●
●
●
●
●
●
●
●
●
●
High performance bridge for 10Base-T or 100Base-TX Ethernet extension.
Auto-MDI/MDIX detects and corrects crossed cable.
Ethernet LAN Interface on RJ-45 connector.
Transparent half / Full duplex support on WAN / LAN interface.
Automatic LAN table learning and aging.
IEEE 802.3x flow control.
Filter mode (pure bridge) or repeater mode selectable
Provides Ethernet over E1 economically
No IP address settings required
Simple DIP switch setting to control filtering, packet buffer and
Ethernet auto/forced mode
Bridge
LAN
General
LAN Table: 256 MAC address with 5 minute automatic aging
Filtering and Forwarding : wire speed
Packet size; 64~1522 Bytes
Buffer : 340 frames
Delay : 1 frame
Standard : compliant to IEEE802.3 /803.2u
Data rate : 10Base-T / 100Base-TX, Full or Half Duplex
Connector : RJ45
IP bridging over G.703 E1
ISO standard HDLC encapsulation
WAN Speed: Nx64 (where N=1 to 31) for Fractional
E12048Kbps for Unframed E1
5
Unframed E1 to Data Card
ERM0 1 -E 1 U/Data
The high-speed data cards are available in two E1 types; one for fractional E1 and one for Unframed E1 (transparent) and with data communication interfaces for V.35, RS-530, X.21 and RS-449(V.36). All line cards come with adapter cables that terminate in the appropriate user interface for DCE. Simple DIP Switch settings provide all the control for E1 and Dataport settings. When the ERM01 is equipped with optional
SNMP, centralized management can configure and monitor the card and performance without manual DIP setting.
●
●
●
●
●
Features
HS (2Mb/s) Serial interface card for serial transport over G.703 E1.
DIP switch or SNMP managed (Optional)
Hot swappable without effecting any other line card
Front panel pushbuttons to activate loop testing with integral 511 pattern BERT.
LED status indicators for E1 Signal, Sync and Dataport TD, RD, and CD.
Specifications
● Compliant with ITU-T standards for V.35, RS-530, X.21 and V.36
●
●
Synchronous transmission at 2.048Mbps
Line code: NRZ
● Control Signals: CTS always ON
Cable Adapter :
HDB26M to MB34F for V.35
HDB26M to DB25F for RS-530
HDB26M to DB37F for RS-449(V.36)
HDB26M to DB15F for X.21
w w w. c t c u . c o m
Ordering Information
E1U/ET100 :
E1U/ET100R :
E1U/V35 :
E1U/RS530 :
E1U/RS449 :
E1U/X21 :
E1U/RS422 :
Unframed E1 to 10/100Base-T/Tx Ethernet Bridge
Unframed E1 to 10/100Base-T/Tx Ethernet Router
Unframed E1 to V.35 with cable adapter
Unframed E1 to RS530 with cable adapter
Unframed E1 to RS449 with cable adapter
Unframed E1 to X21 with cable adapter
Unframed E1 to RS422 with cable adapter
ERM01-FE1/ET100
5-6
Table of Contents
T1 Access Concentrator
Managed T1(DS1) Concentrator
TRM01
The TRM01 is a 4U 19(23)" rack type T1 DSU/CSU for unframed T1 and Fractional T1 Digital Access which is nested in a hub to provide solutions for central office installations. There are 13 slots available for hot swappable T1 (DS1) cards for installation into the TRM01 rack. An optional SNMP card can be installed into the last slot for configuration and management, leaving 12 slots available for T1 (DS1) cards. The SNMP card provides both local control via an RS-232 serial console port and remote management using industry standard SNMP protocol via an Ethernet 10BASE-T connection. Each T1 (DS1) card may be linked to a remote T1/FT1 stand-alone Access Unit for various
LAN, Video Conference, or hosts over T1 (DS1) network services. The TRM01 accommodates an optional second hot swappable shared power supply module which may derive power from AC (90-250) or DC (-48V) power sources. On the rear panel, combinations of RJ-45 and wire-wrap terminals are utilized for T1
(DS1) Line interface connections. Adapter cables are used to convert the HDB26F DCE data ports to V.35, RS-530, RS-449,
X.21 or 10/100 Base Ethernet depending on the installed card.
●
●
●
●
●
●
●
Features
Supports Fractional T1 and Unframed T1 service
Hot swappable cards
Removable interfaces, support V35, X21, RS530,
RS449, RS232, Ethernet Bridge and Router
I/O connectors on rear panel
Multiple clock source selection
(Internal or External: T1 recovery, DTE or DCE)
Supports Console and SNMP management
Performing local and remote loopback
T1 Interface
Frame format: Frame/Unframed, SF (D4), ESF
Bit rate: 1.544Mbps
Line Code: B8ZS / AMI
Receiving level: 0 to -36dB
Pulse amplitude: Nominal 3.0V ±10%
Zero amplitude: ±0.1V
Transmit frequency tracking :
Internal timing±30 ppm
Loopback timing±50 ppm,
External timing±100 ppm
Jitter Performance: According to ITU-T G.824
Connector: RJ-45 (balanced)
Data Interface
Indications
Standards
Power Input
Power Consumption
Dimensions
Weight
Temperature
Humidity
Certification
MTBF
Interface types: RS-530/RS-449/RS-232, X.21/V.35,
10/100Base-T Ethernet Bridge & Router
Connector: HDB26 Female
Line code: NRZ (except bridge)
Data Rate: 1.544Mbps (Unframed/framed)
Nx56kbps or Nx64Kbps
Time slot allocation: user defined
Power, TD, RD, Error, Test, Signal loss, Sync loss,
Alarm LED: Sync Loss, Signal Loss, Alarm
(AIS, MRAI, RAI), TD, RD, Error, Test.
ITU-T G.703, G.704, G.706,G.733, G.824,
ANSI T1.403, AT&T TR-62411
AC: 100 ~ 240VAC DC: -36 ~ -76
80W
Chassis: 285 x 438 x 180mm (D x W x H)
Line card: 260 x 22 x 180mm (D x W x H)
6.6kg
0~50°C (Operating), 0~70°C (Storage)
10~90% non-condensing
CE, FCC, RoHS
57,000 hrs (25°C)
5-7
100 B as e-T X
R S -449
N*64K bps
X 21
V 35
NMS
TR M01
T1
Network
NMS
TR M01
V 35
N*64K bps
X 21
R S - 449
100 B as e-
TRM01 www.ctcu.com
Table of Contents
T1 Access Concentrator
TRM01 overview
Secondary power
Main power
Fractional T1 with
Terminal Block, or RJ-45 interface connector
SNMP Card
13 line cards can be installed into the rack
12 when the SNMP optional card is installed
T1 Balanced RJ-45 Alarm Relay Contacts
Main Switch
T1 CSU/ DSU Slide-in Card
Network Management Card
TRM01-SNMP
Ethernet Router Card
Fractional T1 to 10/100Base-TX
TRM01-ET100R
Ethernet Bridge Card
Fractional T1 to 10/100Base-TX
TRM01-ET100
T1 to Data Card
Fractional T1 to Data Card
TRM01-V35
TRM01-RS530
TRM01-RS449
TRM01-X21
TRM01-RS422
HDB26F Data Port IEC AC Mains Input
RJ-45 + Data port mode chassis back view
5
Ordering Information
TRM01 Chassis
TRM01/AC-CH : AC power type chassis, w/ T1 RJ45
TRM01/DC-CH : DC power type chassis, w/ T1 RJ45
Power Card
TRM01-AC :
TRM01-DC :
100~240VAC power card
48VDC, 72VDC power card w w w. c t c u . c o m
Optional Networking management module
TRM01-SNMP : SNMP card with RS-232 and 10Base-T
Optional T1 cards for TRM01 series
TRM01-V35 : Fractional T1 to V.35 card
TRM01-X21 :
TRM01-RS530 :
TRM01-RS449 :
TRM01-RS422 :
TRM01-ET100 :
TRM01-ET100R :
Fractional T1 to X21 card
Fractional T1 to RS530 card
Fractional T1 to RS449 card
Fractional T1 to RS422 card
Fractional T1 to 10/100Base-Tx Ethernet Bridge
Fractional T1 to 10/100Base-Tx Ethernet Router
TRM01
5-8
Table of Contents
T1 CSU/ DSU Slide-in Card
Fractional T1 to Data Card
TRM0 1 -Data
The high-speed data cards support in two T1 types; fractional T1 and Unframed T1 (transparent) and with data communication interfaces for
V.35, RS-530, X.21 and RS-449(V.36). All line cards come with adapter cables that terminate in the appropriate user interface for DCE. Simple
DIP Switch settings provide all the control for T1 and Dataport settings. When the TRM01 is equipped with optional SNMP, centralized management can configure and monitor the card and performance without manual DIP setting.
●
●
●
●
●
Features
HS (up to 1.544Mb/s) Serial interface card for serial transport over G.703 T1.
DIP switch or SNMP managed (Optional)
Hot swappable without effecting any other line card
Front panel pushbuttons to activate loop testing with integral 511 pattern BERT.
LED status indicators for T1 Signal, Sync and Dataport TD, RD, and CD.
Specifications
● Compliant with ITU-T standards for V.35, RS-530, X.21 and V.36
●
●
Synchronous transmission at Nx64 data rate (1.544M for Unframed)
Line code: NRZ
● Control Signals: CTS always ON
5
Cable Adapter :
HDB26M to MB34F for V.35
HDB26M to DB25F for RS-530
HDB26M to DB37F for RS-449(V.36)
HDB26M to DB15F for X.21
Fractional T1 to 10/100Base-TX
Ethernet Bridge Card
TRM0 1 -ET100
The TRM01-ET100 Bridge Card is a single slot card that can be installed in any available slot to provide Ethernet over T1 transmission. The bridge engine uses an ASIC design for wire speed performance and supports industry standard HDLC encapsulation. The TRM01-ET100 bridge is an economical solution for LAN to LAN applications over Fractional T1 transport.
Features
●
●
●
●
●
●
●
●
●
●
High performance bridge for 10Base-T or 100Base-TX Ethernet extension.
Auto-MDI/MDIX detects and corrects crossed cable.
Ethernet LAN Interface on RJ-45 connector.
Transparent half / Full duplex support on WAN / LAN interface.
Automatic LAN table learning and aging.
IEEE 802.3x flow control.
Filter mode (pure bridge) or repeater mode selectable
Provides Ethernet over T1 economically
No IP address settings required
Simple DIP switch setting to control filtering, packet buffer and
Ethernet auto/forced mode
Bridge
LAN
General
LAN Table: 256 MAC address with 5 minute automatic aging
Filtering and Forwarding : wire speed
Packet size; 64~1522 Bytes
Buffer : 340 frames
Delay : 1 frame
Standard : compliant to IEEE802.3 /803.2u
Data rate : 10Base-T / 100Base-TX, Full or Half
Duplex
Connector : RJ45
IP bridging over G.703 T1
ISO standard HDLC encapsulation
WAN Speed: Nx64 (where N=1 to 24) for Fractional
T1, 1544Kbps for Unframed T1 w w w. c t c u . c o m TRM01-Data / TRM01-ET100
5-10
Table of Contents
T1 CSU/ DSU Slide-in Card
Fractional T1 to 10/100Base-TX
Ethernet Router Card
TRM01-ET100R
The TRM01-ET100R Router Card is a single slot card that can be installed in any available slot to provide IP over T1 transmission. The router engine uses an embedded system which can be configured and controlled from a serial port, Telnet or Web based user interface. It supports industry standard encapsulations of PPP and HDLC as well as proprietary header for Cisco router's HDLC.
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Features
Ethernet port IP Address/subnet mask
WAN port IP Address/subnet mask
Router Name / Password
RS-232 Console Port Management
Web/Telnet Management
WAN port IP address/subnet mask
DHCP server/client
NAT Function
Virtual Server Mapping
SNMP MIB-2 supported
Supports VPN pass through
Forwarding IP multicast support
DNS proxy server
SNTP supported
Simple Statistical
Ping and Trace route
Static Routing Setup
Routing Table (manually set up to 32 entries minimum)
Dynamic Routing RIP I & II, Send or Receive on Ethernet or WAN
PPP, HDLC and Cisco HDLC WAN protocol encapsulatoin
Flash Upgrade (via TFTP)
Hardware
Connection
WAN Speed
LAN Speed
Functions
Protocols
Security
LED
Samsung ARM9 integrated communications
166MHz processor, 8MB Flash, and 32MB pipeline RAM for code, data and buffers
1 x Ethernet LAN port (10/100)
Synchronous Port N56/N64 up to 1544Kbps
Ethernet LAN port 10/100 Mbps
Proxy Routing, IP Routing, Static Routing,
Dynamic Routing, DHCP Client/ DHCP
Server, IP Mapping, Packet Filtering
PPP, NAT, RIP 1/2, TCP/IP
PAP/CHAP, NAT, Filter
Link/ACT : On=link ; Flash=Activity
100 : On=100Base ; Off=10Base
E thernet
T R M01
T R M01-E T 100R
T1 Network
TT U01 -E T 100R
E thernet
Ordering Information
TRM01-ET100R : Fractional T1 to 10/100Base-Tx Ethernet Router
5-11
TRM01-ET100R www.ctcu.com
Table of Contents
E1 Access Unit
Single Modular Port E1
CSU/DSU w/ LCD and SNMP
ETU01A
The ETU01A single port stand-alone DSU/CSU provides our best digital access solution for E1 and Fractional E1 network services termination. A DTE device may be linked to an
ETU01A at data rates of 56Kbps to 2048Kbps. The ETU01A features user replaceable dataport modules for a number of interface standards; including Ethernet bridge, router, V.35,
X.21, RS-530, RS-449, G.703 64Kbps Co-directional and
RS-232. The ETU01A supports local control and diagnostics via
LCD display, keypad and LED status indicators located on the front panel as well as via a menu driven RS-232 console port in conjunction with a standard terminal.
These features enable users to easily configure the unit, execute the in-service diagnostics and monitor the network status. The ETU01A provides optional SNMP (Simple Network
Management Protocol), which allows the user to remotely control, diagnose and monitor the system using industry standard SNMP protocol, our proprietary MIB-II, and any network management software.
●
Features
Supports Fractional E1 and Unframed E1 service with EOC control
●
●
●
●
●
●
●
●
Removable interfaces, support V35, X21, RS530, RS449, RS232,
G.703 Co-directional, NRZ, Ethernet Bridge and Router
I/O connectors on rear panel
Multiple clock source selection
(Internal or External: E1 recovery, DTE or DCE)
Supports Console, Telnet and SNMP management
Menu keys and LCD display
SNMP V1, V2C, V3 supported
Supported by EMS
Built-in BERT with V.54 diagnostic capabilities for performing local and remote loopback
G.703 E1
Specifications
Framing Framed CCS (PCM31) CAS (PCM30) /
Unframed CRC4 on/off
Line Code AMI/ HDB3
LCD display 16*2 character LCD with backlight
Bit rate N*56K or N*64Kbps, where N=1~31 in
CCS or 1~30 in CAS
Transmit level:
Pulse Nominal 2.37V ±10% for 75ohm
Amplitude Nominal 3.00V ±10% for 120ohm
Zero amplitude ±0.1V
Diagnostics
Indications
Standards
Power Input
Power Consumption
Dimensions
Weight
Temperature
Humidity
Certification
MTBF
Connectors BNC(unbalanced), RJ-48(balanced)
Clock modes:
Clock mode 0 Receive & transmit clock
(DCE1) (recovered) to the sync DTE
Clock mode 1 Receive & transmit clock
(DCE2) (internal oscillator) to the sync DTE
Clock mode 2 Receive clock to the sync and transmit
(DTE1) clock from the sync device
Clock mode 3 Receive and transmit clock from the
(DTE2) sync DCE (from ETC and ERC pin)
Clock mode 4 Receive and transmit clock from the
(DTE3) sync DCE (all from ETC pin)l local loopback,Digital remote loopback,
Test pattern
LEDs (Power, TD, RD, RTS, DCD, Singal loss,
Sync loss, Alarm)
ITU-T G.703/G.704/G.706 & G.732
AC: 90-250VAC, DC: 18-72 VCD
10W
250 x 195 x 45mm (D x W x H)
1.5kg
0~50°C (Operating) ,-1~70°C (Storage)
10~90% non-condensing
CE, FCC, LVD, RoHS
65,000 hrs (25°C)
5
NMS
V 35 E T U01A E T U01A
V 35
E1 Network
R S -530
(2.048 Mbps ) E 1
E T U01A
Ordering Information
ETU01A Power type
ETU01A-AC : AC power
ETU01A-DC : DC power
ETU01A-AD : AC+DC power
Optional Interface Module
ETU/TTU-ET100 : 10/100TX Ethernet card
ETU/TTU-ET100R : 10/100TX Router card
ETU/TTU-V35 : V35 interface card
ETU/TTU-X21 : X21 interface card
ETU/TTU-RS530 : RS530 interface card
E T U01A
R S -530
(2.048 Mbps )
ETU/TTU-RS449 : RS449 interface card
ETU/TTU-RS232 : RS232 interface card
ETU/TTU-G64 : G703 64K co-directional card
ETU/TTU-NRZ : NRZ interface card w w w. c t c u . c o m ETU01A 5-12
E1 Access Unit
Single Modular Port E1 CSU/DSU
ETU011
Table of Contents
ETU01
ETU011
The ETU011 stand-alone DSU/CSU is a digital access unit for
Unframed E1, Fractional E1, or Fractional cascaded E1 service.
The ETU011 data channel supports user-selectable transmission rates via randomly selected E1 timeslots, which provides integral multiples of 64kbps, up to a maximum 2.048Mbps (unframed), for a line attenuation of up to 43 dB on twisted pair or coax cable. This provides an approximate operating range up to 2km (using
22AWG). The ETU011 packs the data channels into the E1 link in user-selected time slots. The unused time slots can insert IDLE code (in frame mode). The ETU011 front panel sports status LEDs for monitoring both the CSU and DSU conditions and push button switches for initiating local and remote loopback with integral BERT.
●
●
●
●
●
●
Features
Supports Fractional E1 and Unframed E1 service with EOC control
Removable interfaces, support V35, X21, RS530, RS449, RS232,
G.703 Co-directional, NRZ, Ethernet Bridge and Router
I/O connectors on rear panel
Multiple clock source selection
(Internal or External: E1 recovery, DTE or DCE)
Built-in BERT with V.54 diagnostic capabilities for performing local and remote loopback
G.703 E1
Specifications
Framing
Line Code
Framed CCS (PCM31) CAS (PCM30)
/ UnframedCRC4 on/off
AMI/ HDB3
Transmit level :
Pulse Nominal 2.37V ±10% for 75ohm
Amplitude Nominal 3.00V ±10% for 120ohm
Zero amplitude ±0.1V
Indications
Standard
Power Input
Power Consumption
Dimensions
Weight
Temperature
Humidity
Certification
MTBF
Connectors BNC(unbalanced), RJ-48(balanced)
Clock modes :
Clock mode 0 Receive & transmit clock
(DCE1) (recovered) to the sync. DTE
Clock mode 1 Receive & transmit clock
(DCE2) (internal oscillator) to the sync. DTE
Clock mode 2 Receive clock to the sync. and transmit
(DTE1) clock from the sync. device
Clock mode 3 Receive and transmit clock from the
(DTE2) sync. DCE (from ETC and ERC pin)
Clock mode 4 Receive and transmit clock from the
(DTE3) sync. DCE (all from ETC pin)
Test Switches Digital local loopback, Analog local
Diagnostics Digital local and remote loopback,
Analog local loopback, Test pattern
LEDs (Power, TD, RD, RTS, DCD, Singal loss,
Sync loss, Alarm)
ITU-T G.703/G.704/G.706 & G.732
AC: 90-250VAC , DC: -18 ~ -75 VCD
10W
250 x 195 x 45mm (D x W x H)
510g
0~50°C (Operating) ,-10~70°C (Storage)
10~90% non-condensing
CE, FCC, RoHS
57,000 hrs (25°C)
V 35
(N*64 K bps )
E R M01
E T U011
V 35
(N*64 K bps )
E 1
E 1
E1 Network
R S -530
(2.048 Mbps ) E 1
E 1
R S -530
(2.048 Mbps )
E T U011 E T U011
5-13
Ordering Information
ETU011 Power type
ETU011-AC : Data port to E1 AC power
ETU011-DC : Data port to E1 DC power
Optional Interface Module
ETU/TTU-ET100 : 10/100TX Ethernet card
ETU/TTU-ET100R : 10/100TX Router card
ETU/TTU-V35 : V35 interface card
ETU/TTU-X21 : X21 interface card
ETU/TTU-RS530 : RS530 interface card
ETU/TTU-RS449 : RS449 interface card
ETU/TTU-RS232 : RS232 interface card
ETU/TTU-G64 : G703 64K co-directional card
ETU/TTU-NRZ : NRZ interface card
ETU011 www.ctcu.com
Table of Contents
E1 Access Unit
Single V35 Port E1 CSU/DSU
ETU01-Plus
The ETU01-Plus stand-alone DSU/CSU is a digital access unit for Unframed E1 or Fractional E1 service. The ETU01-Plus data channel supports user-selectable transmission rates via randomly selected E1 timeslots, which provides integral multiples of
64kbps, up to a maximum 2.048Mbps (unframed), for a line attenuation of up to 43 dB on twisted pair or coax cable. This provides an approximate operating range up to 2km (using
22AWG). The ETU01-PLUS packs the data channels into the E1 link in user-selected time slots. The ETU01-Plus front panel sports status LEDs for monitoring the CSU and DSU conditions and pushbutton switches for initiating local and remote loopback with integral BERT. The ETU01-Plus features a fixed on-board V.35 interface.
Features
● Supports Fractional E1 and Unframed E1 service with EOC control
●
●
●
●
●
Model with fixed V.35 interface for price critical applications
I/O connectors all located on rear panel
Multiple clock source selection
( Internal or External: E1 recovery, DTE or DCE )
Built-in BERT with V.54 diagnostic capabilities for performing local and remote loopback
Fixed V.35 port with MB34F connector
G.703 E1
Specifications
Framing
Line Code
Data rate
Framed CCS (PCM31) CAS (PCM30)
/ Unframed CRC4 on/off
AMI/ HDB3
N*56K or N*64Kbps, where N=1~31 in CCS or N equal 1~30 in CAS
Transmit level
Pulse Nominal 2.37V ±10% for 75 ohm
Amplitude Nominal 3.00V ±10% for 120 ohm
Zero amplitude ±0.1V
Indications
Standards
Power Input
Power Consumption
Dimensions
Weight
Temperature
Humidity
Certification
MTBF
Connectors BNC(unbalanced), RJ-48(balanced)
Clock modes :
Clock mode 0 Receive & transmit clock
(DCE1) (recovered) to the sync DTE
Clock mode 1 Receive & transmit clock
(DCE2) (internal oscillator) to the sync DTE
Clock mode 2 Receive clock to the sync. and transmit
(DTE1) clock from the sync device
Clock mode 3 Receive and transmit clock from the
(DTE2) sync DCE (from ETC and ERC pin)
Clock mode 4 Receive and transmit clock from the
(DTE3) sync DCE (all from ETC pin)
LEDs (Power, TD, RD, RTS, DCD, Singal loss,
Sync loss, Alarm)
ITU-T G.703/G.704/G.706 & G.732
AC: 90-250VAC , DC: -18 ~ -75 VCD
10W
195 x 160 x 45mm (D x W x H)
510g
0~50°C (Operating) ,-10~70°C (Storage)
10~90% non-condensing
CE, FCC, RoHS
55,000 hrs (25°C)
5
V .35/X.21/R S
530/449
(2.048 Mbps )
V .35/X.21/R S
530/449
(2.048 Mbps )
E R M01
E T U01-Plus
E 1 E 1
E T U01-Plus
V .35/X.21/R S
530/449
(2.048 Mbps )
E 1
E1 Network
E 1
E T U01-Plus
V .35/X.21/R S
530/449
(2.048 Mbps )
Ordering Information
ETU01-Plus-AC : V35 port to E1 with AC power
ETU01-Plus-DC : V35 port to E1 with DC power
ETU01-Plus-ADT-AC-C5/C4 : Power plug adapter w w w. c t c u . c o m ETU01-Plus
5-14
Table of Contents
E1 Access Unit
Single Port Unframed E1 CSU/DSU
G703E1U
The G703E1U stand-alone DSU/CSU is a compact, digital access unit for Unframed E1 service termination. The G703E1U data channel supports 2.048Mbps, for a line attenuation of up to
43 dB on twisted pair or coax cable. This provides an approximate operating range up to 2km (using 22AWG). The G703E1U top panel sports status LEDs for monitoring both the CSU and DSU condition and slide switches for initiating digital or analog loopback.
●
●
●
●
●
Features
Supports Unframed E1
Support fixed V35, X21, RS530, RS449 with cable adapter
Easily configure with simple DIP switches
(DTE, DCE, Framing, time slot, clock mode, etc.)
Multiple clock source selection
(Internal or External: E1 recovery, DTE or DCE)
Performing local and remote loopback
G.703 E1
Specifications
Framing
Line Code
Unframed
HDB3
Bit rate 2.048Mbps
Relative receive level 0 to -43dB
Transmit level
Pulse Nominal 2.37V ±10% for 75ohm
Amplitude Nominal 3.00V ±10% for 120ohm
Zero amplitude ±0.1V
Data port
Specifications
Indications
Standards
Power Input
Power Consumption
Dimensions
Weight
Temperature
Humidity
Certification
MTBF
Connectors BNC(unbalanced), RJ-48(balanced)
CRC check CRC-4 enable/disable
Type
Line code
Data rate
Connector
RS530, V35, RS449, X21
NRZ
64kbps ~ 2.048Mbps
DB25F plus cable
LEDs (E1 signal, timing loss)
ITU-T G.703, G.706 and G.823
9VDC (AC adapter)
4W
135 x 79 x 28mm (D x W x H)
180g
0~50°C (Operating) ,0~70°C (Storage)
10~90% non-condensing
CE, FCC, RoHS
57,000 hrs (25°C)
V .35/X.21/R S
530/449
(2.048Mbps )
G 703E 1U
Unframed E 1
E1 Network
G 703E 1U
V.35/X.21/RS
530/449
(2.048Mbps)
Ordering Information
G703E1U Data port to Unframed E1
5-15
G703E1U www.ctcu.com
Table of Contents
New
E1/T1 Cross-Rate Converter Rack
2U 20-slot E1/T1 Cross Rate
Converter Rack
ETRM01
The ETRM01 is a 2U 19(23)" concentrator rack for E1 and T1 Cross Rate Converters in central office installations. There are
20 slots available for hot swappable FTEC cards. An optional SNMP card can be installed into the first slot for configuration and management, leaving 19 slots available for FTEC cards. The SNMP card provides both local control via an RS-232 serial console port and remote IP management using Telnet, web GUI, SNMP protocol. Each E1 card may be linked to a remote
E1/T1 PABX or a stand-alone FTEC Unit. The ETRM01 accommodates an optional second hot swappable shared power supply module which may derive power from AC (100-240) or DC (-48V) power sources. On the front panel of FTEC, combinations of BNC and RJ-45 connectors are utilized for E1 and T1 Line interface connections.
5
Features
●
●
●
●
●
●
●
●
Support G.802 Annex B
Enables equipment to operate at T1 and E1 rates.
Converts between T1 and E1 data and signaling.
Configurable A-law/u-law and signaling conversion.
Transparent conversion at 64kbps timeslot level.
Controlled slip for buffer over/underflow.
The 24 timeslots of T1(Nx64) can be inserted into
E1(Nx64), 30/CAS or 31/CCS timeslots.
Local/remote loopback test capabilities on both
T1 and E1 interface.
●
●
Complies with ITU-T G.703, G.704, G.823,
G.824 recommendations.
Function setting via internal DIP switch setting or
Console Port.
(When SNMP card installed) Timing selection:
T1/E1 recovery timing
Internal timing (1.544Mbps/2.048Mbps)
External timing (1.544Mbps/2.048Mbps)
20-slot E1/T1 Cross-Rate Converter Rack overview
2
1
2
3
Support E1/T1 Cross-Rate Converter
Chassis backplane consists of passive components
NMC Card for ETRM01 E1/T1 Cross-Rate Converter Rack
3 1
4
7 7
5 6
4
6
7
4
5
Hot swappable Cooling fans
Chassis cascade up to 10 with one management IP
Alarm relay
Single or optional redundant power supplies w w w. c t c u . c o m ETRM01
E1/T1 Cross-Rate Converter Rack
Table of Contents
Power Redundancy
All the ETRM01 chassis power supplies are hot swappable and modular, installing two into a chassis provides redundancy should a single power supply fail. A fully loaded chassis can run continuously with only one power module fitted into the chassis.
Cooling Fan
To further increase system reliability, the ETRM01 chassis is fitted with two hot swappable fan modules. Both fan modules can be easily removed from the rear of the chassis, without interruption to the operation of the line cards. A fully loaded chassis can run continuously with only one fan module fitted into the chassis.
Chassis cascade
The ETRM01 features cascadeable management which allows managing a stack (up to 10 chassis) from a single IP address. Chassis are interconnected with standard UTP cables that carry control signals. Each chassis has its own ID, starting with the master chassis ID0 and cascading up to ID9.
Network Management
The ETRM01 chassis provides an NMC (Network Management Controller) card which must be installed into the first slot of chassis. The NMC card allows a network administrator with the ability to configure and monitor the status of the blades.
Management can be achieved locally over RS232, or over the network by Telnet, Web or SNMP If the blades support
Ethernet in the First Mile (IEEE 802.3ah), then the management module can also configure and monitor the status of a remote blade.
ETRM01 Applications
P B X
T1
E T R M01
G 703F T E C
T1
E1
T1
T1
E1
Network
E T R M01
G 703F T E C
E1
T1
Ordering Information
ETRM01 Chassis
ETRM01-CH20 : 2U 19” 20 slot chassis
ETRM01-AC : 100 ~ 240 AC power card
ETRM01-DC24 : 18 ~ 36 DC power card
ETRM01-DC48 : 36 ~ 72 DC power card
Example
: ETRM01-CH20
Optional Cards
ETRM01-NMC : Network Management Controller
ETRM01-FTEC : E1/T1 Cross Rate Converter
Example
: ETRM01-FTEC
5-21 ETRM01 www.ctcu.com
Table of Contents
Network Management Card
ETRM0 1-NMC
E1/T1 Cross-Rate Converter Rack Slide-in Card
This single slot card is installed in the first slot of the chassis. The card has an RS-232 serial port on a DB9 female connector for connection of any standard dumb terminal for an easy menu driven configuration. The RJ-45 jack is a 10/100
Ethernet connector for IP based management. The NMC card supports a remote Telnet Web GUI management with the same user friendly interface as local console. NMC can be used by compiling the enterprise MIB into your favorite network management software.
Features
● RS-232 port for dumb terminal at 115.2k, 8bit, no parity
● Ethernet port for 10/100Base-TX compliant with IEEE802.3u
● SNMP V1 and V2C support
● MIB file compliant to MIB-II ASN.1
● Firmware upgrade by TFTP
● Hot swappable
5
E1,T1 Cross-Rate Converter
ETRM0 1-FTEC
New
The ETRM01-FTEC is E1,T1 cross rate card. The time slot cross connect enables the conversion between one T1 signal and one E1 signal. T1 and E1 signals with frames employ u-Law and A-Law compander encoding principles respectively and encode those analog signals into 64kbits digital data. The
E1 interface supports CCS (PCM31)or CAS (PCM30) frames with or without CRC-4 and with HDB3 line coding. The T1 interface supports D4 or ESF frame formats with B8ZS or AMI line code. Multiple clock source selection provides maximum flexibility in connecting both T1 and E1.
Features
●
●
●
●
●
●
●
●
Converts between T1 and E1 data and signaling
Enable equipment to operate at T1 and E1 rates
Support G.802 Annex B
Configures A-law/m-law and signaling conversion
Transparent conversion at 64kbps timeslot level
Controlled slip for buffer over or under flow
24 timeslots of T1 Nx64 can be inserted into E1 Nx64,
30/CAS or 31/CCS timeslots w w w. c t c u . c o m ETRM01 5-22
Table of Contents
E1 Access Multiplexer
4U, 10 I/O Slot Data, Ethernet,
Voice E1 Managed Multiplexer
ERM-Mux / Plus
The ERM-Mux / plus is a 4U 19(23)" 14 slot rack type E1 Time Division Multiplexer for Fractional E1 network access which is designed for non-stop operation.There are 10 slots available for hot-swappable ERM-Mux / plus-I/O cards. Two slots are provided for Mux-E1 cards, which may be configured as four separate E1links or for redundant 1+1 operation of the E1 lines, safe guarding against expensive network down time.
Two slots are also available for CPU cards, with the second CPU card acting as a hot standby in case of primary card failure. Each Mux-E1 card may be linked to another ERM-Mux / plus Rack to provide a point-to-point variety of datacom, Ethernet & voice over E1 network services. The
ERM-Mux/plus optionally accommodates up to two separate powerpplies, which may derive power from AC (110/220) or DC (-48V) power sources. When two power supplies are installed, the modules provide complete power redundancy and are hot swappable even during the E1 cards' transmission. The ERM-Mux/plus provides all interface connections on the front panel. BNC and RJ-45 are used for E1 Line interface connections, RJ-45 connections are used for all voice (FXO, FXS, E&M), for 10/100 Ethernet Bridge and G.703-64K co-directional / contra-directional / center. Optional cable adapters are used to convert the DB-62F DCE ports of the I/O cards to 6xRS-232, HP68F DCE port of
I/O card to 4x V.35, RS-232, RS-530, RS-449, RS-422 and X.21 or 5x X.50 channels.
ERM-Mux/plus overview
CPU Cards
E1 Trunk Cards
Interface Cards
AC, DC Power Redundancy
Features
CPU redundancy (1+1)
E1 redundancy (1+1 ) and E1 card redundancy
Power redundancy (1+1) [2AC, 2DC, AC+DC]
DCE hot swappable card types
4ch V.35 (nx64K)
4ch G.703 64K co-directional /contra-directional / center mode
2ch Ethernet bridge
6ch RS232
6ch FXS voice
6ch FXO voice
6ch E&M voice
Drop & Insert function
Console, NMP,SNMP, management
G703 Ext. clock BNC Port
G703 Ext. clock RJ45 Port
Cooling Fan
Main Alarm/ Sub Alarm/
Relay/ Connector
Auto-resume
AC Power socket
SNMP Port
RS485 Port
Multi-case
Case Expanding
Specifications
Connectors
Console port (RJ45, RS232C)
WAN port RJ45 Jack (2-wire, 4-wire)
Physical Specifications
Dimensions: 350 x 438 x 176mm (W x D x H)
Weight: 8kg (chassis+dual power+8 I/O cards) 450g per card
Power Characteristics
AC : AC 90 ~250VAC
DC : DC -48VDC
Environmental Specifications
Operating 0°C to 60°C
Storage 0°C to 70°C
Relative humidity 0% to 90% non-condensing
Predicted MTBF : 65,000 hrs (25°C)
Certification
CE
5-23
ERM-Mux/Plus www.ctcu.com
Table of Contents
E1 Voice/Data Access Multiplexer
4U, 10 I/O Slot Data, Ethernet,
Voice E1 Managed Multiplexer
ERM-Mux/Plus
Application
Connection with PBX (Program Controlled Exchanger)
Build A
SW
Ethernet
SW
E1
DDN/ PDH/ SDH
PCM/ Microwave
FXS
Phone PBX
E&M
RTU
E1
ERM-MUX/PLUS
Build B
Ethernet
Ethernet
FXS
E&M
SW
SW
PBX
Phone
RTU
The extension and expansion of DDN
(Data Distribution Network)
B
SW SW
Ethernet Ethernet FXS
C
Phone
PBX RTU
ERM -MUX/PLUS
E&M
PDH
E1
A
LAN PBX RTU
E1
ERM -MUX/PLUS
D
5-25
ERM-Mux/Plus www.ctcu.com
Table of Contents
E1 Access Multiplexer
1U, 3 I/O Slot Data, Ethernet,
Voice E1 Managed Multiplexer
ETU02-MUX-Plus
The ETU02-MUX/PLUS is a 1U 19(23)" 3 slot rack type E1 Time Division Multiplexer for Fractional E1 network access which provides an economic solution for central site or remote installations. There are 3 slots available for hot-swappable ETU02-MUX/PLUS-I/O cards. One slot is provided for MUX-E1 card, which provides either single E1 main link or main E1 link plus a drop and insert sub-E1 port. The MUX-E1 card may be linked to another ETU02-MUX/PLUS or ERM-MUX/PLUS
Rack to provide a point-to-point variety of datacom, Ethernet & voice over E1 network services. The ETU02-MUX/PLUS optionally accommodates up to two separate power supplies, which may derive power from AC (110/220) or DC (-48V) power sources. When two power supplies are installed, the modules provide complete power redundancy and are hot swappable even during the E1 cards' transmission. The ETU02-MUX/PLUS provides BNC and RJ-45 for E1 Line interface connections, RJ-45 connections are used for all voice (FXO, FXS, E&M), for 10/100 Ethernet Bridge and G.703/64K Co-directional. Optional cable adapters are used to convert the DB-62F DCE ports of the I/O cards to 4xRS-232 or HP68F DCE ports of I/O card to 2x V.35, RS-530, RS-449, RS-422 and X.21 channels.
●
●
●
●
●
Features
●
1U 19” 3-slot chassis
Provides 3 slots, removable interfaces: V35, X21, RS530, RS449,
RS232, G.703 Co-directional, Ethernet Bridge, FXO, FXS and E&M
Optional drop and insert E1 port (Sub E1)
Setup and Control via RS-232 terminal
Multiple clock source selection
(Internal or External: E1 recovery, DTE or DCE)
Optional SNMP management
Specifications
Indications
Standard
Power
Power Consumption
Dimensions
Weight
Temperature
Humidity
MTBF
Power, Signal loss, Sync loss,
Alarm (AIS, MRAI, RAI), TD, RD, Error, Test
ITU-T G.703/G.704/G.706 & G.732, G823
AC: 90 ~250V
20W
235 x 438 x 45 mm (D x W x H)
2.9kg
0~50°C (Operating) ,-10~70°C (Storage)
10~90% non-condensing
57,000 hrs (25°C)
X.50 card
●
●
●
●
●
Specifications
Interface types
Connector
Line code
Data rate
Loopback type
RS232
DB62F with cable adapter
NRZ
2.4K ~ 19.2kpbs x 5Ch
Local/Remote loopback
Ordering Information
ETU02-MUX-Plus Chassis
ETU02-MUX-PLUS-AC :
ETU02-MUX-PLUS-DC48 :
ETU02-MUX-PLUS-DC24 :
1U 19" 3+1 slot Chassis with AC Power
1U 19" 3+1 slot Chassis with DC 48V Power
1U 19" 3+1 slot Chassis with DC 24V Power
ETU02-MUX-Plus Slide-in card
ETU02-MUX-PLUS-E1 : E1 BNC card
ETU02-MUX-PLUS-Sub E1 :
ETU02-MUX-PLUS-N64 :
E1+ sub E1 BNC card
2ch V35/X21/RS530 card
ETU02-MUX-PLUS-RS232 : 4port RS232 card
ETU02-MUX-PLUS-RS232C : 4port RS232 card w/ Clock
ETU02-MUX-PLUS-ET100 :
ETU02-MUX-PLUS-FXS :
ETU02-MUX-PLUS-FXO :
ETU02-MUX-PLUS-E&M :
ETU02-MUX-PLUS-G64 :
2port 10/100TX card
4port FXS card
4port FXO card
4port E&M card
2port G.703 64K card
F ram R elay
Network
DDN
Network
X.25
Network E T U02-MUX/P L US
Ethernet bridge
●
●
●
●
●
●
10/100Base-TX bridge
Auto-Negotiation
Auto MDI/MDIX
Forward 1522 bytes (Max.) packets
Supports IEEE 802.1q Tag VLAN pass thru
Support flow control (Pause)
Standard IEEE 802.3/802.3u
Connector
Frames
WAN protocol
WAN rate
RJ-45 x 2
10/100Base-TX, Auto-negotiation
Supports 64-1522 bytes packet length
Synchronous HDLC
N*64Kbps, up to 2048Kbps
Specifications
LAN Specifications
●
●
Standard
Connector
Fully compliant with IEEE 802.3/802.3u
RJ-45x2
●
●
Speed
Frames
10Base-T/100Base-TX, Full or half duplex
Supports 64 to 1522 byte packet lengths standard and extended length frames for VLAN tagging, etc.
WAN Specifications
●
●
Protocol
Rates
Synchronous HDLC
N*64 or N*56Kbps, up to 2048Kbps
E T U02-MUX/P L US
P B X
5-31
ETU02-MUX-Plus
E T U02-MUX/ P L US
E R M-MUX/ P L US
P B X www.ctcu.com
Table of Contents
G.703/64K co-directional card
●
●
●
●
●
●
●
2-channels , Co-directional 64K interface
Interface type: ITU-T G.703/64K
Connector: RJ-45 x 2
Line code: Co-directional
Data rate: 64Kbps ± 100ppm x 2-channels
Line impedance: 120 ohm (balanced)
Frame mode: Unframed only
●
●
●
●
●
●
Specifications
Interface types
Connector
Line code
Data rate
Line impedance
Frame mode
G.703/64K, Co-directional
RJ45 x 2
ITU-T G.703/64K, Co-directional
64kpbs±100ppm x 2 channels
120 ohms
Unframed only
RS-232 card
●
●
●
●
●
●
4-channels
Interface type: RS-232 (V.24)
Connector: HD62 female with appropriate cable adapter
Line code: NRZ
Data rate: Asynchronous mode <= 38.4Kbps (4-channels),
Synchronous mode = 19.2/38.4/64/128Kbps
●
●
●
●
Specifications
Interface
Connector
Line code
Data rate
RS232
HD62F with cable adapter
NRZ
3.84kbps x 4ch or 64/128kbps x 4ch
E&M
●
●
●
●
●
●
●
BD/GD wires are for battery and ground detection
E&M card provides 4 independent channels
E&M interface provides 1 pair of E and 1 pair of M
Each E&M can support Type I, II, III, IV or V
Loop current range is normally 5-30mA, 70mA max
Timeslot 16 complies with ITU-T G.711
TX / RX attenuation, and 2 / 4 wire operation
Specifications
●
●
●
●
●
Input level
Output level
Impedance
Return loss
Group delay
●
●
●
●
●
●
Total distortion
Channel cross-talk
Level not to exceed
Noise
Interface connector
0 to -16dBr, in 0.5dB steps
0 to -16dBr, in 0.5dB steps
600 ohms, option
2-wire 300-600Hz: >12dB
2-wire 600-3400Hz: >15dB
4-wire 300-3400Hz: >20dB
2-wire @ -10dBm: < 750μ second
4-wire @ -10dBm: < 600μ second
According to ITU-T G223
Not exceed -65dB, 1020Hz@0dBm
-50dBm
<-65dBm
RJ-45*4 w w w. c t c u . c o m
E1 Access Multiplexer
E1 and Sub E1 module
●
●
Single E1 or 1+1 E1 card (E1 and Sub-E1), provides unbalanced
BNC or balanced RJ45 connector
Each E1 loop provides clock to be used as system clock source
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Specifications
Connectors
Framing Framed
CRC check
Bit rate
Line code
Line impedance
Relative receive level
BNC for unbalanced ; RJ-45 for balanced
Unframed / Framed CCS(PCM31) / CAS(PCM30)
CRC4 on/off
2.048Mbps±0 ppm
AMI / HDB3
75 ohm(BNC) / 120 ohm(DB-15, RJ-45)
0 to -43dB
Pulse amplitude
Zero amplitude
Transmit frequency
Tracking
External
Jitter performance
Compliance
Nominal 2.37V ±10% for 75ohm
Nominal 3.00V ±10% for 120ohm
±0.1V
Internal timing ±30 ppm
Recovery timing ±50 ppm timing±100 ppm
According to ITU-T G.823
ITU G.703, G.704, G.706, G.732
5
Nx64 card
●
●
●
●
●
2-channels , High speed data interface
Interface type: V35/RS-530/X.21/RS-449
Connector: HD68 female with appropriate cable adapter
Line code: NRZ
Data rate: N*64kbps, where N=1 to 31 in CCS
N=1 to 30 in CAS
●
●
●
●
Specifications
Interface types
Connector
Line code
Data rate
RS530, X.21, V.35, RS449, RS232
HD68F with cable adapter
NRZ
Nx64kbps
FXS
●
●
Provides 4 independent channels
Connects to standard telephones
●
●
●
●
●
●
●
●
●
●
Specifications
Connector
Impedance
Level Gain
Ring current Output
Frequency
Feeding voltage
Loop resistance
Connecting distance
Wire Gauge
RJ45 x 4
600 ohms
On Tx side 0 dB On Rx side -3.5dB
75±15V
25±3Hz
-48
1800 ohms up to 4km
0.4mm
FXO
●
●
Provides 4 independent channels
Connects directly to PSTN
●
●
●
●
●
●
Specifications
Connector
Impedance
Level Gain
RJ-45*4
600 ohms
On Tx side 0 dB On Rx side -3.5dB
ETU02-MUX-Plus
5-32
Table of Contents
E1 Access Multiplexer
E1 Mux 4 Data Port sub E1 w/ SNMP
ETU02-MUX
5-33
The ETU02-MUX is a 1U 19(23)" 4 slot rack mountable multiplexing solution for Fractional E1 network services. Up to four
DTE devices may be linked to this model at data rates of 64Kbps to 2048Kbps. There is also provision for one optional E1 sub-link which will perform drop & insert with user-defined timeslot connections from a PABX or other E1 equipment to E1 network services. The Fractional E1 2 or 4 port multiplexer supports local control and diagnostics via an LCD display and LED status indicators located on the front panel or via a serial console port.
These features enable users to easily configure the unit, execute the in-service diagnostics and monitor the network status. The
ETU02-MUX provides for optional SNMP Network Management
System, which allow the user to remotely control and manage the system via SNMP protocol. This model fully meets all of the E1 specifications including ITU-T G.703, G.704, G.706, G.732, and
G.823.
●
●
●
●
●
●
Features
Provides 4 slots, removable interfaces: V35, X21, RS530, RS449,
RS232, G.703 Co-directional, NRZ, Ethernet Bridge and Router.
Optional drop and insert E1 port (Sub E1)
Built-in BERT with V.54 diagnostic capabilities for performing local and remote loopback
Setup and Control via front Panel with LCD display or RS-232 terminal
Multiple clock source selection (Internal or External: E1 recovery,
DTE or DCE)
Optional SNMP management
Ordering Information
ETU02-Mux4-AC : E1 Mux with 4 data ports, AC power
ETU02-Mux4-DC : E1 Mux with 4 data ports, DC power
ETU02-Mux4-AD : E1 Mux with 4 data ports, AC+DC power
ETU02-Mux2-AC : E1 Mux with 2 data ports, AC power
ETU02-Mux2-DC : E1 Mux with 2 data ports, DC power
ETU02-Mux2-AD : E1 Mux with 2 data ports, AC+DC power
E1 and Sub-E1
Transmitter level
Framing
Framed
Bit rate
Line code
Unframed / Framed CCS(PCM31)/
CAS(PCM30)
2.048Mbps±0 ppm
AMI / HDB3
Pulse amplitude
Nominal 2.37V ±10% for 75ohm
Nominal 3.00V ±10% for 120ohm
Tracking Recovery timing±100 ppm
External timing±100 ppm
Return loss 12dB for 51 ~ 102KHz
18dB for 102 ~ 2048KHz
14dB for 2048 ~ 3072KHz
Data rate Nx56Kbps or Nx64Kbps User Data Channel
Loopback
DSR constantly on, except during test loops
DCD constantly on or follows RTS,
except during signal loss
Line, Payload, local, DTE loopback
Clock modes
Key Pad
LCD
Indications
Standard
Power Input
Power Consumption
Dimensions
Weight
Temperature
Humidity
Certification
MTBF
2e23-1, All 1, All 0, Alt, 0011, 3 in 24
, 1 in 16, 1 in 8,1 in 4 test pattern.
Clock mode 0 (DCE1) Receive and transmit clock
(recovered) to the sync DTE
Clock mode 0 (DCE2) Receive and transmit clock
(internal oscillator0 to the sync DTE
Clock mode 0 (DCE3) Receive and transmit clock from the
sync DCE (from ETC and ERC pin)
Clock mode 0 (DCE4) Receive and transmit clock from the
sync DCE (all from ETC pin)
4 operation keys
16 x 2 character backlit LCD
Signal loss, Sync loss, Alarm (AIS, MRAI, RAI), TD, RD,
Error, Test
ITU-T G.703/G.704/G.706, G.732 & G823
AC: 90 ~250V,
DC24: -18 ~-36VDC, DC48: -36 ~-72VDC
10W
235 x 438 x 45mm (D x W x H)
2.9kg
0~50°C (Operating) ,-10~70°C (Storage)
10~90% non-condensing
CE, FCC, RoHS
57,000 hrs (25°C)
E thernet
R outer
X.21/RS-530/449
(N*64Kbps)
V .35
(N*64K bps )
S ub E 1
P B X
E T U02-MUX
E 1 E 1
E T U02-MUX
E thernet
S ub E 1
V .35
(N*64K bps )
R outer
X.21/RS-530/449
(N*64Kbps)
P B X
ETU02-MUX www.ctcu.com
PDH Concentrator
- FRM220 Family
Managed PDH Concentrator
ERM04
The ERM04 is a 2U high 19" Rack, 20 slot modular rack. It provides an economic solution in high density fiber converter installations in enterprises or central offices. All critical components, Power, fans, management module and interface cards are hot swappable, allowing online field replacement. The hot-swappable power modules can be chosen from
AC100-240V, DC18-36. or DC 36-75V. The chassis also has a pair of alarm relays and is able to stack up to 10 chassis with one management IP address. This chassis is also compatible with other FRM220 line cards.
Connectors
Console RS232(DB9)
LAN 10/100 Base TX RJ45
Physical Specifications
Dimensions: 303mm x 438mm x 88mm (W x D x H)
Weight: 5.2kg w/o P/S
Power Characteristics
AC : 100 ~ 240VAC
DC24 : 18 ~ 36VDC, DC48: 36 ~ 75VDC
Environmental Specifications
Operating 0°C ~ 50°C
Storage -10°C ~ 70°C
Relative humidity 5% ~ 90% non-condensing
Predicted MTBF : 65,000 hrs
Certification
FCC class A, VCCI class A, CE, RoHS
5-35
20-slot PDH Concentrator overview
4
3
7
2
1
7
5 6
4
1
Support 4-port E1/T1+100M Fast Ethernet card
Support E1/T1 Cross-Rate Converter card
Support E1 to Data card
Support 5E1 / 8E1 / 16E1 Inverse Multiplexer
Support E1 Ethernet Bridge card
Support Network Management Controller
2
3
Chassis backplane consists of passive components
NMC card for ERM04 Element Management system
4
5
6
7
Hot swappable Cooling fans
Chassis cascade up to 10 with one management IP
Alarm relay
Single or optional redundant power supplies
Ordering Information
Chassis Type
ERM04-CH : 2U 19” 20 slot chassis
ERM04-AC : 100 ~ 240 AC power card
ERM04-DC24 : 18 ~ 36 DC power card
ERM04-DC48 : 36 ~ 72 DC power card
Slide-in card Type
FRM220-NMC : Network Management Controller card
FRM220-FOM04 : 4-port E1/T1+100M Fast Ethernet card
FRM220-FTEC : E1/T1 Cross-Rate Converter card
FRM220-E1/Data : E1 to Data card
FRM220A-Eoe1 : E1 Ethernet Bridge card
FRM220A-iMUX5 : 5E1 (10Mbps) Inverse Multiplexer card
FRM220A-iMUX8 : 8E1 (16Mbps) Inverse Multiplexer card
FRM220A-iMUX16 : 16E1 (32Mbps) Inverse Multiplexer card
Smart View
Element Management System
(EMS)
Platform server
SV-PLF05 :
5 Client user admission
SV-PLF25 :
25 Client user admission
SV-PLF50 :
50 Client user admission
Device Agents
SV-AGT-50:
50 Device agents
SV-AGT-100:
100 Device agents
SV-AGT-200:
200 Device agents
SV-AGT-500:
500 Device agents
Managed Modules
SV-PDH :
ERM04
Example: SV-PLF-05, SV-AGT-50, SV-PDH
ERM04 www.ctcu.com
PDH Concentrator
-FRM220 Family
ERM04 Chassis Introductions
Power Redundancy
All the ERM04 chassis power supplies are hot swappable and modular, installing two into a chassis provides redundancy should a single power supply fail. A fully loaded chassis can run continuously with only one power module fitted into the chassis.
Cooling Fan
To further increase system reliability, the ERM04 chassis is fitted with two hot swappable fan modules. Both fan modules can be easily removed from the rear of the chassis, without interruption to the operation of the line cards. A fully loaded chassis can run continuously with only one fan module fitted into the chassis.
Chassis cascade
The ERM04 features cascadeable management which allows managing a stack (up to 10 chassis) from a single IP address. Chassis are interconnected with standard UTP cables that carry control signals. Each chassis has its own ID, starting with the master chassis
ID0 and cascading up to ID9.
Network Management
The ERM04 chassis provides an NMC (Network Management Controller) card which must be installed into the first slot of chassis. The
NMC card allows a network administrator with the ability to configure and monitor the status of the blades.
Management can be achieved locally over RS232, or over the network by Telnet, Web or SNMP If the blades support Ethernet in the First Mile (IEEE 802.3ah), then the management module can also configure and monitor the status of a remote blade.
Protocol Supported
The ERM04 chassis has been designed as a Multi-serivce platform. This allows network administrators to deploy the chassis in a wide range of networks. Technologies supported by the chassis included Fast/Gigabit Ethernet, E1/T1, V35/X21/RS530, Serial RS485/422,
Voice FXO/FXS, Repeater, Fiber Multiplexer, E1 Inverse Multiplexer and 10G, 2.7G Transponder.
5
PDH Concentrator Slide-in card overview
Network Management Controller
Network Management Card
Network Management
ERM04-NMC
Network Management System
Smart View EMS
(Element Management System)
SV-PDH
Functions
• Fault Management (FM)
• Performance Management (PM)
• Configuration Management (CM)
• Security Management (SM)
Fiber Optical Multiplexer
Fiber Optical Multiplexer
FOM04
●
●
●
●
●
●
●
●
●
Functions
4 channels unframed E1/T1
10/100Base-TX Ethernet
Auto MDI/MDIX
Auto-Negotiation or Force mode
Supports flow control
Supports 9K jumbo packets
Supports Link fault pass through (LFP)
One clear channel RS232 up to 250Kbps(Async)
1+1 fiber protection, less than 50ms
●
●
●
●
●
●
●
Supports Digital Diagnostics Monitoring Interface (DDMI)
AIS on signal loss on E1/T1 and fiber port
Loopback test on E1/T1, LAN, RS232, fiber ports
Supports Dying Gasp
Supports local or remote In-band management
(Monitor or Configure status) by SNMP manager and console port.
Supports Order wire Ear / Microphone port.
Supports On-Line F/W upgrade.
Ethernet over PDH
Inverse Multiplexer
5E1
Inverse Multiplexer iMUX5
8E1
Inverse Multiplexer iMUX8
16E1
Inverse Multiplexer iMUX16
E1/T1 Access
E1 CSU/DSU
Data to Fractional E1
E1/Data
E1 Access Unit
Ethernet to E1 Converter
Eoe1
E1/T1 Cross Rate Converter
E1 To Data converter
E1 To T1 Converter
G703 FTEC w w w. c t c u . c o m ERM04
5-36
Management
Network Management Controller
ERM04-NMC
The ERM04-NMC is a Network Management Controller card that can be placed in a compatible ERM04 series chassis to provide network management functions. The management interface supports a local RS-232 serial console or remote TCP/IP management by Telnet, HTTP or SNMP protocols. The card is designed to be hot swapped so that it may be field replaced without affecting any online service of any other rack cards. The card also supports online firmware upgrade from TFTP server, using any user interface. Support for any standard NMS is provided by the included proprietary MIB file.
CTC Union also provides and maintains their own EMS (Element
Management System) which is a Java based client/server manager for monitoring and maintaining a large number of network elements over a long period of time.
Electrical
Interface
Management
Interface
● Console RS232 port
● LAN 10/100Base-TX
Features
●
●
●
●
●
●
●
●
●
Supports local / remote monitor and configuration.
Supports local / remote online TFTP f/w upgrade
Line card status & info display
Supports multiple accesses for SNMP management
Supports Web GUI management, Telnet, Serial console
Supports console RS-232 port and 10/100Base-T Ethernet port
Supports SNMP standard MIB II and proprietary MIB
Supports NTP time synchronization
Supports 100 entries system log
Indications
Dimensions
Weight
Temperature
Humidity
Certification
MTBF
● Network management: provide all system
OAM functions: software updates, and management system interaction through
Ethernet port.
● Out-band management: supports Web,
Telnet and SNMP , EMS management
● Configuration Management
● Performance Management
● Fault Management
● Status Monitoring.
● PWR, Fan, Alarm Act, STK, LAN LNK/SPD
● 155 x 88 x 23mm (DxWxH)
● 120g
● 0 ~ 50oC (Operating) , -10 ~ 60oC (Storage)
● 10 ~90% non-condensing
● CE, FCC, LVD, RoHS
● 65,000 hrs (25oC)
Serial Console Management
****************************************
*** CTC UNION TECHNOLOGIES CO., LTD. ***
*** ERM04 SNMP VER. 1.95 ***
****************************************
This Chassis ID:[00] Cascaded:[Yes] Monitored Chassis ID:[00]
Chassis List:[Master]
#0:[X] #1:[ ] #2:[ ] #3:[ ] #4:[ ] #5:[ ] #6:[ ] #7:[ ] #8:[ ] #9:[ ]
<1>:SLOT #01 > SNMP & Chassis <B>:SLOT #11 > ERM04-8E1
<2>:SLOT #02 > ERM04-5E1 <C>:SLOT #12 > ERM04-8E1
<3>:SLOT #03 > ERM04-5E1 <D>:SLOT #13 > ERM04-8E1
<4>:SLOT #04 > ERM04-5E1 <E>:SLOT #14 > ERM04-8E1
<5>:SLOT #05 > ERM04-5E1 <F>:SLOT #15 > ERM04-16E1
<6>:SLOT #06 > ERM04-5E1 <G>:SLOT #16 > ERM04-16E1
<7>:SLOT #07 > ERM04-5E1 <H>:SLOT #17 > ERM04-16E1
<8>:SLOT #08 > ERM04-5E1 <I>:SLOT #18 > ERM04-16E1
<9>:SLOT #09 > ERM04-5E1 <J>:SLOT #19 > ERM04-16E1
<A>:SLOT #10 > ERM04-5E1 <K>:SLOT #20 > ERM04-16E1
<->:Monitor Previous Chassis <+>:Monitor Next Chassis
<L>:SNMP System Configuration Setup
<M>:SNMP Manager Configuration Setup
<P>:Password Setup
<R>:Reboot <Z>:Logout
Please select an item
Web GUI Manager
ERM04
Ordering Information
ERM04-NMC : Network Management Controller
5-37
ERM04-NMC www.ctcu.com
E1 Inverse Multiplexer
5E1 (10Mbps) Inverse Multiplexer
iMux5
The iMux is a slide-in card E1 inverse multiplexer capable of bundling up to 5 E1 lines for cost-effective connection of
10/100BaseTX or 100Base-FX LANs over multiple E1 transports. The iMux5 inverse multiplexer transmits up to a
9.92Mbps Ethernet bridge channel (GFP-F encapsulated) over 5
E1 links. The iMux5 bridges the gap between E1 and E3, allowing bridges to operate at faster rates. It also provides high speed access to SDH/SONET backbones where the only access services available are E1 lines. The iMux5 supports an E1 attenuation of up to 43 dB on twisted pair or coax cable. This provides an approximate operating range up to 2km (using
22AWG). The iMux5 fully meets E1 specifications including
ITU-T G.703 and G.823. The iMux5 features diagnostic capabilities for performing remote loopback. The operator at either end of the line may test both the iMux5 and the line in the digital loopback mode. The Ethernet copper interface supports auto-negotiation and auto MDI/MDIX, allowing plug-and-play
Ethernet connection without any additional configuration.
Interface
●
●
●
●
●
●
●
●
Features
Connects one Fast Ethernet over 5E1 links (1.984Mbps to 9.92Mbps)
Built-in GFP bridge operates at WAN rate
Auto-Negotiation
Maximum 220ms delay variance between E1 link
Unbalanced E1/BNC or balanced E1/RJ45
Fully compatible with ERM04 chassis
SNMP management with ERM04 chassis
LED Alarm indication
Framing
Standard
CCS+CRC
ITU-T G.703/G.704/G.706 & G.732, G.823
Bit rate
Line code
2.048Mbps± 50ppm (up to 5E1)
HDB3
Clock setting Internal OSC or recovery clock
Receive level -43dB
Pulse Mask Complies with ITU-T G.703
Indications
Power Input
Power Consumption
Dimensions
Weight
Temperature
Humidity
Certifications
MTBF
Connector
Diagnostics
Standard
Data rate
RJ45, BNC
Digital remote loopback
IEEE 802.3, 802.3u
10/100Base-TX, Half/Full duplex
Connector
100Base-FX
RJ45 10/100Base-TX
SFP-LC 100Base-FX
Power, ALM,E1 signal loss ,
E1 Alarm(AIS,LOF, RAI, LOMF),
LAN link /ACT, 10/100M , SD(100Base-FX)
AC adapter : 100~240VAC to 12VDC
100 ~ 240VAC, 18 ~ 75VDC
< 12W
DC12 : 160 x 88 x 24mm (D x W x H)
AC/DC48/AD : 201 x 135 x 35mm (D x W x H)
DC 12 : 280g , AC/DC48/AD : 580g
0 ~ 50°C (Operating), -10 ~ 70°C (Storage)
10 ~ 90% RH (non-condensing)
CE, FCC, RoHS
7,500 hrs (25°C)
5
Central Office (CO)
NMS/ EMS
IP Network
ERM04 iMux5
Inserted in 20-Slot chassis
5E1
Backbone
5E1
Customer Premise Equipment (CPE) iMux5
10/100TX iMux5
5E1
10/100TX iMux5
5E1
10/100TX
LAN
LAN
LAN w w w. c t c u . c o m
Ordering Information
FRM220A-iMux5T-R : Ethernet to 5x E1 RJ45 with 5E1 RJ45 adapter cable
FRM220A-iMux5T-B : Ethernet to 5x E1 BNC with 5E1 BNC adapter cable
FRM220A-iMux5S-R : 100Base-FX SFP to 5x E1 RJ45 with 5E1 RJ45 adapter cable
FRM220A-iMux5S-B : 100Base-FX SFP to 5x E1 BNC with 5E1 BNC adapter cable iMUX5
5-38
E1 Inverse Multiplexer
8E1 (16Mbps) Inverse Multiplexer
iMux8
The iMux8 is a slide-in card E1 inverse multiplexer capable of bundling up to 8 E1 lines for cost-effective connection of
10/100BaseTX or 100Base-FX LANs over multiple E1 transports. The iMux8 inverse multiplexer transmits up to a
15.87Mbps Ethernet bridge channel (GFP-F encapsulated) over
8 E1 links. The iMux8 bridges the gap between E1 and E3, allowing bridges to operate at faster rates. It also provides high speed access to SDH/SONET backbones where the only access services available are E1 lines. The iMux8 supports an E1 attenuation of up to 43 dB on twisted pair or coax cable. This provides an approximate operating range up to 2km (using
22AWG). The iMux8 fully meets E1 specifications including
ITU-T G.703 and G.823. The iMux8 features diagnostic capabilities for performing remote loopback. The operator at either end of the line may test both the iMux8 and the line in the digital loopback mode. The Ethernet copper interface supports auto-negotiation and auto MDI/MDIX, allowing plug-and-play
Ethernet connection without any additional configuration.
Interface
●
●
●
●
●
●
●
●
Features
Connects one Fast Ethernet over 8E1 links (1.984Mbps to
15.87Mbps)
Built-in HDLC bridge operates at WAN rate
Auto-Negotiation
Maximum 220ms delay variance between E1 link
Unbalanced E1/BNC or balanced E1/RJ45
Fully compatible with ERM04 chassis
SNMP management with ERM04 chassis
LED Alarm indication
Framing
Standard
Bit rate
Line code
CCS+CRC
ITU-T G.703/G.704/G.706 & G.732, G.823
2.048Mbps± 50ppm (up to 8E1)
HDB3
Clock setting Internal OSC or recovery clock
Receive level -43dB
Pulse Mask Complies with ITU-T G.703
Indications
Power Input
Power Consumption
Dimensions
Weight
Temperature
Humidity
Certifications
MTBF
Connector
Diagnostics
Standard
Data rate
BNC / RJ45
Digital remote loopback
IEEE 802.3, 802.3u
10/100Base-TX, Half/Full duplex
Connector
100Base-FX
RJ45 10/100Base-TX
SFP-LC 100Base-FX
Power, ALM,E1 signal loss ,
E1 Alarm(AIS,LOF, RAI, LOMF),
LAN link /ACT, 10/100M , SD(100Base-FX)
AC adapter : 100~240VAC to 12VDC
100 ~ 240VAC, 18 ~ 75VDC
< 12W
DC12 : 160 x 88 x 24mm (D x W x H)
AC/DC48/AD : 201 x 135 x 35mm (D x W x H)
DC 12 : 280g, AC/DC48/AD : 580g
0 ~ 50°C (Operating), -10 ~ 70°C (Storage)
10 ~ 90% RH (non-condensing)
CE, FCC, RoHS
7,500 hrs (25°C)
IP Network
Central Office (CO)
NMS/ EMS
ERM04 iMux8
Inserted in 20-Slot chassis
8E1
Backbone
8E1
Customer Premise Equipment (CPE) iMux8
10/100TX iMux8
8E1
10/100TX iMux8
8E1
10/100TX
LAN
LAN
LAN
5-39
Ordering Information
FRM220A-iMux8T-R : Ethernet to 8x E1 RJ45 with 8E1 RJ45 adapter cable
FRM220A-iMux8T-B : Ethernet to 8x E1 BNC with 8E1 BNC adapter cable
FRM220A-iMux8S-R : 100Base-FX SFP to 8x E1 RJ45 with 5E1 RJ45 adapter cable
FRM220A-iMux8S-B : 100Base-FX SFP to 8x E1 BNC with 5E1 BNC adapter cable iMux8 www.ctcu.com
E1 Inverse Multiplexer
16E1 (32Mbps) Inverse Multiplexer
iMux16
The iMux16 is a slide-in card E1 inverse multiplexer capable of bundling up to 16 E1 lines for cost-effective connection of
10/100BaseTX or 100Base-FX LANs over multiple E1 transports. The iMux16 inverse multiplexer transmits up to a
31.74Mbps Ethernet bridge channel (GFP-F encapsulated) over
16 E1 links. iMux16 bridges the gap between E1 and E3, allowing bridges to operate at faster rates. It also provides high speed access to SDH/SONET backbones where the only access services available are E1 lines. The iMux16 supports an E1 attenuation of up to 43 dB on twisted pair or coax cable. This provides an approximate operating range up to 2km (using
22AWG). The iMux16 fully meets E1 specifications including
ITU-T G.703 and G.823. The iMux16 features diagnostic capabilities for performing remote loopback. The operator at either end of the line may test both the iMux16 and the line in the digital loopback mode. The Ethernet copper interface supports auto-negotiation and auto MDI/MDIX, allowing plug-and-play
Ethernet connection without any additional configuration.
Interface
●
●
●
●
●
●
●
●
Features
Connects one Fast Ethernet over 16E1 links(1.984Mbps to
31.74Mbps)
Built-in HDLC bridge operates at WAN rate
Auto-Negotiation
Maximum 220ms delay variance between E1 link
Unbalanced E1/BNC or balanced E1/RJ45
Fully compatible with ERM04 chassis
SNMP management with ERM04 chassis
LED Alarm indication
Framing
Standard
Bit rate
Line code
CCS+CRC
ITU-T G.703/G.704/G.706 & G.732, G.823
2.048Mbps± 50ppm (up to 16E1)
HDB3
Clock setting Internal OSC or recovery clock
Receive level -43dB
Pulse Mask Complies with ITU-T G.703
Indications
Power Input
Power Consumption
Dimensions
Weight
Temperature
Humidity
Certifications
MTBF
Connector
Diagnostics
Standard
Data rate
RJ45, BNC
Digital remote loopback
IEEE 802.3, 802.3u
10/100Base-TX, Half/Full duplex
Connector
100Base-FX
RJ45 10/100Base-TX
SFP-LC 100Base-FX
Power, ALM,E1 signal loss ,
E1 Alarm(AIS,LOF, RAI, LOMF),
LAN link /ACT, 10/100M , SD(100Base-FX)
AC adapter : 100~240VAC to 12VDC
100 ~ 240VAC, 18 ~ 75VDC
< 12W
DC12 : 160 x 88 x 24mm (D x W x H)
AC/DC48/AD : 201 x 135 x 35mm (D x W x H)
DC 12 : 280g , AC/DC48/AD : 580g
0 ~ 50°C (Operating), -10 ~ 70°C (Storage)
10 ~ 90% RH (non-condensing)
CE, FCC, RoHS
7,500 hrs (25°C)
5
Central Office (CO)
NMS/ EMS
IP Network
ERM04 iMux16
Inserted in 20-Slot chassis
16E1
Backbone
16E1
Customer Premise Equipment (CPE) iMux16
10/100TX iMux16
16E1
10/100TX iMux16
16E1
10/100TX
LAN
LAN
LAN w w w. c t c u . c o m
Ordering Information
FRM220A-iMux16T-R : Ethernet to 16x E1 RJ45 with two 8E1 RJ45 adapter cables
FRM220A-iMux16T-B : Ethernet to 16x E1 BNC with two 8E1 BNC adapter cables
FRM220A-iMux16S-R : 100Base-FX SFP to 16x E1 RJ45 with two 8E1 RJ45 adapter cables
FRM220A-iMux16S-B : 100Base-FX SFP to 16x E1 BNC with two 8E1 BNC adapter cables iMux16
5-40
4-port E1/T1+100M Ethernet
Fiber Multiplexer
FOM04
FOM04 is a modular design for 4xE1/T1 + Fast Ethernet multi-service to dual strand fiber PDH multiplexer. FOM04 provides E1/T1 transmission transparently, pure 100Mbps Fast
Ethernet simultaneously. The fiber optic line is based on the
SFP technology that allows a flexible use of Multimode or Single mode lines and enable the support of different wavelengths and distances. The use of bi-directional SFPs maximizes the utilization of the fiber optic line and results in saving line costs.
With SNMP and Web-based management in the FRM220, the
Network administrator can monitor, configure and control the activity of each card in the chassis.
Features
● 4 channels unframed E1/T1
● 10/100Base-TX Ethernet
● Auto MDI/MDIX
● Auto-Negotiation or Force mode
●
●
Supports flow control
Supports 9K jumbo packets
● Supports Link fault pass through (LFP)
● One clear channel RS232 up to 250Kbps(Async)
● 1+1 fiber protection, less than 50ms
● Supports Digital Diagnostics Monitoring Interface (DDMI)
● AIS on signal loss on E1/T1 and fiber port
● Loopback test on E1/T1, LAN, RS232, fiber ports
● Supports Dying Gasp
● Supports local or remote In-band management
(Monitor or Configure status) by SNMP manager and console port.
● Supports Order wire Ear / Microphone port.
● Supports On-Line F/W upgrade.
E1/T1 ports
Framing
Bit Rate
Line Code
Line Impedance
Receiver sensitivity
“Pulse" Amplitude
“Zero" Amplitude
Transmit Frequency Tracking
Internal Timing
Jitter Performance
Performance monitoring
Standard
Interface Connectors
Test Loops
Unframed (transparent)
E1:2.048 Mb/s , T1: 1.544Mb/s
E1:AMI/HDB3, T1: AMI/B8ZS
E1: Unbalanced 75 ohms (BNC cable)
E1: Balanced 120 ohms (RJ-45)
T1: Balanced 100 ohms (RJ-45)
Short haul
Nominal 2.37V+/-10% for 75 ohms
Nominal 3.00V+/-10% for 120 ohms
Nom
+/-0.3V w/external clock card option
+/-30 ppm
According to ITU-T G.823
According to ITU-T G.821
ITU-T G.703, G.704, G.706 and G.732
RJ-45, BNC
LLB (Local Loop Back)
NELB (Near End Loop Back)
RLB (Remote Loop Back)
RRLB (Request Remote Loop Back)
Ethernet
Interface Type
Connector
Standard
Duplex modes
Test
10/100Base-TX
RJ-45
IEEE 802.3, 802.3u full/half
Loop back test
Indications
Power Input
Dimensions
Temperature
Humidity
Certifications
FX1 Link, FX2 link, E1/T1 Mode/Link/Loopback test,
Order wire phone indicator, LAN Link/Speed.
AC adapter, 12VDC
88 x 42 x 139mm(DxWxH)
0 ~ 60°C (Operating), -10 ~ 70°C (Storage)
10 ~ 90% RH (non-condensing)
CE, FCC, RoHS
5-41
STM1
Managed 4E1/T1 + Fast
Ethernet Fiber Optical
Multiplexer
Order
Wire
RS232 clear channel
ERM04
4E1/T1
EMS
PDH Fiber Optic
Multiplexer Platform
Local
Management
FOM04
RS232 clear channel
Order
Wire
4E1/T1
LAN
PBX
Ordering Information
FRM220-FOM04 : 4-port E1/T1+100M Ethernet Fiber Multiplexer
Smart View Element Management System (EMS)
SV-PLF-05 (5, 25, 50) : Platform Server (5, 25, 50 admissions)
SV-AGT-50 (50,100,200,500) : Device Agent (50, 100, 200, 500 Devices)
SV-PDH : ERM01X Managed Module
Order
Wire
1+1 Fiber
Protection
LAN
FOM04
4E1/T1
PBX
Local
Management
LAN www.ctcu.com
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement