Enrange XLTX Transmitter

Wireless Controls

April 2011

Part Number:

178-01598-1000-R3

©Copyright 2011 Magnetek Material Handling

Your New Radio Remote

Thank you for your purchase of Magnetek’s Enrange

®

brand XLTX Radio Wireless Controls.

Magnetek has set a whole new standard in radio-remote performance, dependability, and value with this unique new line of bellybox transmitters.

If your product ever needs modification or service, please contact one of our representatives at the following locations:

U.S. Service Information

For questions regarding service or technical information contact:

1.866.MAG.SERV

(1.866.624.7378).

Magnetek, Inc.

N49 W13650 Campbell Drive

Menomonee Falls, WI 53051

Telephone: 1.800.288.8178

Website:

e-mail:

Fax Numbers:

Main:

Sales:

Service: www.magnetekmobilehydraulic.com [email protected]

1.800.298.3503

1.262.783.3510

1.262.783.3508

Canada Service Information:

4090B Sladeview Crescent

Mississauga, Ontario

L5L 5Y5 Canada

Phone: 1.800.792.7253

Fax: 1.905.828.5707

1.416.424.7617 (24/7 Service pager)

©2011 MAGNETEK

All rights reserved. This notice applies to all copyrighted materials included with this product, including, but not limited to, this manual and software embodied within the product. This manual is intended for the sole use of the person(s) to whom it was provided, and any unauthorized distribution of the manual or dispersal of its contents is strictly forbidden. This manual may not be reproduced in whole or in part by any means whatsoever without the expressed written permission of MAGNETEK.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 2 of 40

TABLE OF CONTENTS

1.0

 

1.1

INTRODUCTION .................................................................................................................. 5

  PRODUCT MANUAL SAFETY INFORMATION ............................................................... 5  

 

1.2

2.0

 

2.1

2.2

 

 

  WARNINGS and CAUTIONS ............................................................................................ 6  

CRITICAL INSTALLATION CONSIDERATIONS ................................................................. 7

GENERAL ......................................................................................................................... 7

PERSONS AUTHORIZED TO OPERATE RADIO CONTROLLED EQUIPMENT ........... 7

2.3

2.4

2.5

  SAFETY INFORMATION AND RECOMMENDED TRAINING FOR RADIO

CONTROLLED EQUIPMENT OPERATORS .............................................................................. 8

 

 

 

2.6

2.7

2.8

3.0

 

 

  TRANSMITTER UNIT ....................................................................................................... 9  

 

  PRE-OPERATION TEST .................................................................................................. 9  

  HANDLING BATTERIES ................................................................................................. 10  

OPTIONAL RECHARGABLE BATTERY CHARGING ................................................... 10

BATTERY DISPOSAL ..................................................................................................... 10

 

 

  XLTX TRANSMITTER STANDARD CONFIGURATION AND OPERATION ..................... 11  

3.1

 

3.1.1

3.1.2

3.1.3

3.1.4

3.2

3.2.1

3.2.2

INSTALLING BATTERY PACK(S) .................................................................................. 12

  Alkaline Battery Pack (BT129) ................................................................................. 12  

  Optional NiMH Rechargeable Battery Pack (BT128) .............................................. 13  

  Spare Battery Storage Compartment ...................................................................... 14  

  Setting Battery Type Dip Switches .......................................................................... 14  

 

3.2.3

3.3

3.4

3.5

 

 

  TURNING THE TRANSMITTER ON AND OFF .............................................................. 15  

  Turning On the Transmitter ...................................................................................... 16  

  Pulling In the Machine Stop Relay ........................................................................... 16  

  Turning Off the Transmitter ...................................................................................... 16  

MACHINE STOP SWITCH (For Emergency Stopping Only) .......................................... 16

GRAPHIC USER INTERFACE ...................................................................................... 16

 

 

  NORMAL OPERATING MODE ....................................................................................... 17  

3.5.1

3.5.2

3.5.3

3.5.4

  Watch Dog Indicator (Spinning Arrow) .................................................................... 17  

3.5.5

3.6

3.7

3.8

 

 

  Command Confirmation ........................................................................................... 17  

  Battery Life Indicator ................................................................................................ 17  

  Signal Strength Indicator ......................................................................................... 18  

  Two-Way Feedback System .................................................................................... 18  

JOYSTICKS AND PADDLES/LEVERS .......................................................................... 18

ROTARY SELECTOR SWITCH ..................................................................................... 18

 

 

4.0

 

4.1

 

  AUXILIARY SWITCHES ................................................................................................. 18  

USING THE TRANSMITTER IN SETUP MODE ................................................................ 19

  ENTERING SETUP MODE ............................................................................................. 19  

4.2

4.2.1

4.2.2

4.2.3

4.2.4

4.2.5

ADJUSTING SETTINGS IN SETUP MODE ................................................................... 19

  Access Code ............................................................................................................ 19  

  Channel Select ......................................................................................................... 19  

 

 

4.2.6

4.2.7

4.2.8

4.2.9

 

 

  User Code ................................................................................................................ 20  

  Transmitter Timeout ................................................................................................. 20  

  Backlight Timeout .................................................................................................... 20  

  Password Enable ..................................................................................................... 20  

Change Password .................................................................................................... 21

Exit Without Save ..................................................................................................... 21

 

 

5.0

 

5.1

5.2

5.3

  Exit With Save .......................................................................................................... 21  

OPTIONAL PROGRAMMING WITH RCP .......................................................................... 22

  ACCESS CODES ............................................................................................................ 22  

  CHANGING RECIEVER ACCESS CODES .................................................................... 22  

  CONNECTING THE XLTX TO A COMPUTER............................................................... 23  

  PROGRAMMING WITH RCP ......................................................................................... 24  

 

5.4

5.4.1

5.4.2

 

  XLTX Configuration Pages ...................................................................................... 26

Saving, Downloading, and Reading the Programs and Other RCP Software

Functions ................................................................................................................................ 31

 

 

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 3 of 40

6.0   TRANSMITTER CHANNEL CONFIGURATION SETTINGS ............................................. 33  

6.1

6.2

6.3

 

 

 

6.3.1

6.3.2

FCC STATEMENTS ....................................................................................................... 33

CHANNEL AND FREQUENCY DESIGNATIONS BY COUNT ....................................... 34

OPTIONAL FREQUENCIES AND CHANNELS ............................................................. 35

  900 MHz: FHSS ....................................................................................................... 35  

 

 

 

7.0

 

6.3.3

7.1  

  2.4 GHz: FHSS ........................................................................................................ 35  

  433 MHz Telemotive Legacy Channel Set: TMS and TDMA .................................. 35  

OPTIONAL CAN BUS TETHER FEATURE ....................................................................... 36

INSTALLATION OF TETHER CABLE ......................................................................... 36

 

 

7.2

7.3

7.4

8.0

 

8.1

 

  OPERATION OF TRANSMITTER IN TETHER MODE ............................................... 36  

  RETURNING TRANSMITTER TO WIRELESS MODE ............................................... 36  

CAN CONNECTOR RECEPTACLE PIN-OUT DETAILS ............................................ 37

GENERAL TROUBLESHOOTING .................................................................................... 38

 

 

8.2

 

  TROUBLESHOOTING: OPTIONAL TETHER OPERATION .......................................... 39  

ASSEMBLY AND REPLACEMENT PARTS ................................................................... 40  

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 4 of 40

1.0 INTRODUCTION

Thank you for your purchase of Magnetek’s Enrange

®

brand XLTX Radio Wireless Controls.

These instructions are to be used as a reference for personnel operating the Enrange

®

brand XLTX Radio

Wireless Controls and the equipment that this Enrange

®

brand XLTX Radio Wireless Control is attached to.

The user of these instructions should have basic knowledge in the handling of electronic equipment.

1.1 PRODUCT MANUAL SAFETY INFORMATION

Magnetek, Inc. (Magnetek) offers a broad range of radio wireless controls products, control products and adjustable frequency drives, and industrial braking systems for overhead material handling applications.

This manual has been prepared by Magnetek to provide information and recommendations for the installation, use, operation and service of Magnetek’s material handling products and systems (Magnetek

Products). Anyone who uses, operates, maintains, services, installs or owns Magnetek Products should know, understand and follow the instructions and safety recommendations in this manual for Magnetek

Products.

The recommendations in this manual do not take precedence over any of the following requirements relating to cranes, hoists and lifting devices:

 Instructions, manuals and safety warnings of the manufacturers of the equipment where the radio system is used,

 Plant safety rules and procedures of the employers and the owners of facilities where the

Magnetek Products are being used,

 Regulations issued by the Occupational Health and Safety Administration (OSHA),

 Applicable local, state or federal codes, ordinances, standards and requirements, or

 Safety standards and practices for the overhead material handling industry.

This manual does not include or address the specific instructions and safety warnings of these manufacturers or any of the other requirements listed above. It is the responsibility of the owners, users and operators of the Magnetek Products to know, understand and follow all of these requirements. It is the responsibility of the owner of the Magnetek Products to make its employees aware of all of the above listed requirements and to make certain that all operators are properly trained. No one should use Magnetek

Products prior to becoming familiar with and being trained in these requirements.

WARRANTY INFORMATION

FOR INFORMATION ON MAGNETEK’S PRODUCT WARRANTIES BY PRODUCT TYPE, PLEASE VISIT

WWW.MAGNETEKMOBILEHYDRAULIC.COM.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 5 of 40

Throughout this document WARNING and CAUTION statements have been deliberately placed to highlight items critical to the protection of personnel and equipment.

WARNING – A warning highlights an essential operating or maintenance procedure, practice, etc. which, if not strictly observed, could result in injury or death of personnel, or long term physical hazards. Warnings are highlighted as shown below:

WARNING

CAUTION – A caution highlights an essential operating or maintenance procedure, practice, etc. which, if not strictly observed, could result in damage to, or destruction of equipment, or loss of functional effectiveness. Cautions are highlighted as shown below:

CAUTION

WARNINGS and CAUTIONS SHOULD NEVER BE DISREGARDED.

The safety rules in this section are not intended to replace any rules or regulations of any applicable local, state, or federal governing organizations. Always follow your local lockout and tagout procedure when maintaining any radio equipment. The following information is intended to be used in conjunction with other rules or regulations already in existence. It is important to read all of the safety information contained in this section before installing or operating the Radio Control System.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 6 of 40

2.0 CRITICAL INSTALLATION CONSIDERATIONS

WARNING

PRIOR TO INSTALLATION AND OPERATION OF THIS EQUIPMENT, READ AND DEVELOP AN

UNDERSTANDING OF THE CONTENTS OF THIS MANUAL AND THE OPERATION MANUAL OF THE

EQUIPMENT OR DEVICE TO WHICH THIS EQUIPMENT WILL BE INTERFACED. FAILURE TO FOLLOW

THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT.

ALL EQUIPMENT MUST HAVE A MAINLINE CONTACTOR INSTALLED AND ALL TRACKED CRANES,

HOISTS, LIFTING DEVICES OR SIMILAR EQUIPMENT MUST HAVE A BRAKE INSTALLED. FAILURE

TO FOLLOW THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO

EQUIPMENT.

AN AUDIBLE AND/OR VISUAL WARNING MEANS MUST BE PROVIDED ON ALL REMOTE

CONTROLLED EQUIPMENT AS REQUIRED BY CODE, REGULATION, OR INDUSTRY STANDARD.

THESE AUDIBLE AND/OR VISUAL WARNING DEVICES MUST MEET ALL GOVERNMENTAL

REQUIREMENTS. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN SERIOUS INJURY OR

DEATH AND DAMAGE TO EQUIPMENT.

FOLLOW YOUR LOCAL LOCKOUT TAGOUT PROCEDURE BEFORE MAINTAINING ANY REMOTE

CONTROLLED EQUIPMENT. ALWAYS REMOVE ALL ELECTRICAL POWER FROM THE CRANE,

HOIST, LIFTING DEVICE OR SIMILAR EQUIPMENT BEFORE ATTEMPTING ANY INSTALLATION

PROCEDURES. DE-ENERGIZE AND TAGOUT ALL SOURCES OF ELECTRICAL POWER BEFORE

TOUCH-TESTING ANY EQUIPMENT. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN

SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT.

THE DIRECT OUTPUTS OF THIS PRODUCT ARE NOT DESIGNED TO INTERFACE DIRECTLY TO TWO

STATE SAFETY CRITICAL MAINTAINED FUNCTION, I.E., MAGNETS, VACUUM LIFTS, PUMPS,

EMERGENCY EQUIPMENT, ETC. A MECHANICALLY LOCKING INTERMEDIATE RELAY SYSTEM

WITH SEPARATE POWER CONSIDERATIONS MUST BE PROVIDED. FAILURE TO FOLLOW THIS

WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT.

2.1 GENERAL

Radio controlled material handling equipment operates in several directions. Cranes, hoists, lifting devices and other material handling equipment can be large, and operate at high speeds. Quite frequently, the equipment is operated in areas where people are working in close proximity to the material handling equipment. The operator must exercise extreme caution at all times. Workers must constantly be alert to avoid accidents. The following recommendations have been included to indicate how careful and thoughtful actions may prevent injuries, damage to equipment, or even save a life.

2.2 PERSONS AUTHORIZED TO OPERATE RADIO CONTROLLED EQUIPMENT

Only properly trained persons designated by management should be permitted to operate radio controlled equipment.

Radio controlled cranes, hoists, lifting devices and other material handling equipment should not be operated by any person who cannot read or understand signs, notices and operating instructions that pertain to the equipment.

Radio controlled equipment should not be operated by any person with insufficient eyesight or hearing or by any person who may be suffering from a disorder or illness, is taking any medication that may cause loss of equipment control, or is under the influence of alcohol or drugs.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 7 of 40

2.3 SAFETY INFORMATION AND RECOMMENDED TRAINING FOR RADIO

CONTROLLED EQUIPMENT OPERATORS

Anyone being trained to operate radio controlled equipment should possess as a minimum the following knowledge and skills before using the radio controlled equipment.

The operator should:

 have knowledge of hazards pertaining to equipment operation

 have knowledge of safety rules for radio controlled equipment

 have the ability to judge distance of moving objects

 know how to properly test prior to operation

 be trained in the safe operation of the radio transmitter as it pertains to the crane, hoist, lifting device or other material handling equipment being operated

 have knowledge of the use of equipment warning lights and alarms

 have knowledge of the proper storage space for a radio control transmitter when not in use

 be trained in transferring a radio control transmitter to another person

 be trained how and when to report unsafe or unusual operating conditions

 test the transmitter emergency stop and all warning devices prior to operation; testing should be done on each shift, without a load

 be thoroughly trained and knowledgeable in proper and safe operation of the crane, hoist, lifting device, or other material handling equipment that utilizes the radio control

 know how to keep the operator and other people clear of lifted loads and to avoid “pinch” points

 continuously watch and monitor status of lifted loads

 know and follow cable and hook inspection procedures

 know and follow the local lockout and tagout procedures when servicing radio controlled equipment

 know and follow all applicable operating and maintenance manuals, safety procedures, regulatory requirements, and industry standards and codes

The operator shall not:

 lift or move more than the rated load

 operate the material handling equipment if the direction of travel or function engaged does not agree with what is indicated on the controller

 use the crane, hoist or lifting device to lift, support or transport people

 lift or carry any loads over people

 operate the crane, hoist or lifting device unless all persons, including the operator, are and remain clear of the supported load and any potential pinch points

 operate a crane, hoist or lifting device when the device is not centered over the load

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 8 of 40

 operate a crane, hoist or lifting device if the chain or wire rope is not seated properly in the sprockets, drum or sheave

 operate any damaged or malfunctioning crane, hoist, lifting device or other material handling equipment

 change any settings or controls without authorization and proper training

 remove or obscure any warning or safety labels or tags

 leave any load unattended while lifted

 leave power on the radio controlled equipment when the equipment is not in operation

 operate any material handling equipment using a damaged controller because the unit may be unsafe

 operate manual motions with other than manual power

 operate radio controlled equipment when low battery indicator is on

WARNING

THE OPERATOR SHOULD NOT ATTEMPT TO REPAIR ANY RADIO CONTROLLER. IF ANY PRODUCT

PERFORMANCE OR SAFETY CONCERNS ARE OBSERVED, THE EQUIPMENT SHOULD

IMMEDIATELY BE TAKEN OUT OF SERVICE AND BE REPORTED TO THE SUPERVISOR. DAMAGED

AND INOPERABLE RADIO CONTROLLER EQUIPMENT SHOULD BE RETURNED TO MAGNETEK FOR

EVALUATION AND REPAIR. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN SERIOUS

INJURY OR DEATH AND DAMAGE TO EQUIPMENT.

UNIT

Transmitter switches should never be mechanically blocked ON or OFF. When not in use, the operator should turn the transmitter OFF. A secure storage space should be provided for the transmitter unit, and the transmitter unit should always be placed there when not in use. This precaution will help prevent unauthorized people from operating the material handling equipment.

Spare transmitters should be stored in a secure storage space and only removed from the storage space after the current transmitter in use has been turned OFF, taken out of the service area and secured.

2.5 PRE-OPERATION TEST

At the start of each work shift, or when a new operator takes control of the equipment, operators should do, as a minimum, the following steps before making lifts with any equipment:

Test all warning devices.

Test all direction and speed controls.

Test the transmitter emergency stop.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 9 of 40

WARNING

KNOW AND FOLLOW PROPER BATTERY HANDLING, CHARGING AND DISPOSAL PROCEDURES.

IMPROPER BATTERY PROCEDURES CAN CAUSE BATTERIES TO EXPLODE OR DO OTHER SE-

RIOUS DAMAGE. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN SERIOUS INJURY OR

DEATH AND DAMAGE TO EQUIPMENT.

Use only batteries approved by Magnetek for the specific product.

Do not dispose of a battery pack in fire; it may explode.

Do not attempt to open the battery pack.

Do not short circuit the battery.

Keep the battery pack environment cool during storage (i.e., not in direct sunlight or close to a heating source).

2.7 OPTIONAL RECHARGABLE BATTERY CHARGING

For those transmitters equipped with rechargeable batteries and battery chargers, all users shall be familiar with the instructions of the charger before attempting to use.

Do not attempt to charge non-rechargeable battery packs in the charger.

Avoid charging partially discharged rechargeable batteries to help prolong battery cycle life.

Do not charge batteries in a hazardous environment.

Keep the battery pack environment cool during charging (i.e., not in direct sunlight or close to a heating source).

Do not short the charger.

Do not attempt to charge a damaged battery.

Use only Magnetek Enrange approved chargers for the appropriate battery pack.

Do not attempt to use a battery that is leaking, swollen or corroded.

Charger units are not intended for outdoor use. Only use charger units indoors.

DISPOSAL

Before disposing of batteries consult local and governmental regulatory requirements for proper disposal procedure.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 10 of 40

3.0 XLTX TRANSMITTER STANDARD CONFIGURATION AND OPERATION

WARNING

BEFORE OPERATING THE TRANSMITTER FAMILIARIZE YOURSELF WITH ALL SAFETY

INFORMATION IN THIS MANUAL, THE CORRESPONDING RECEIVER SYSTEM MANUAL,

APPROPRIATE MANUAL SUPPLEMENTS AND ANY OTHER LOCAL, STATE, OR FEDERAL

RULES OR REGULATIONS ALREADY IN EXISTENCE. FAILURE TO FOLLOW THIS

WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO

EQUIPMENT.

Figure 1: Typical XLTX with maximum number of Paddles and Auxiliary Switches

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 11 of 40

3.1 INSTALLING BATTERY PACK(S)

Prior to utilizing the XLTX transmitter, battery packs must be installed (unless unit is being utilized with the optional tether feature - then the battery packs are optional).

3.1.1 Alkaline Battery Pack (BT129)

The XLTX comes standard with a battery pack (BT129) that holds three disposable AA alkaline batteries.

Figure 2: BT129 Battery Pack

To change the alkaline batteries in the battery pack, separate the inner tray from the outer housing (see Figure 2) and replace all the batteries with new ones.

Figure 3: Separated Alkaline Battery Pack

When reinserting the tray into the outer housing, make sure the grooves in the inner tray align with the slides in the outer housing. When placing the battery pack into the XLTX battery pocket, orient the battery pack so that the sticker is facing out (see Figure 4).

Figure 4: Installation of Battery Pack into XLTX transmitter

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 12 of 40

After installing the battery pack, install the battery cover over the battery and secure by tightening the thumbscrew at the end of the battery cover (see Figure 5).

Figure 5: Installation of Battery Cover

NOTE: For the battery level indicator on the XLTX display to display the correct battery level, the battery type dip switch settings need to be set for the battery pack being used. See section 3.1.4 for details on setting the battery type dip switches.

NOTE: If using the optional rechargeable battery pack BT128, review and become familiar with the rechargeable battery charger manual prior to use.

The rechargeable battery pack BT128 is a sealed battery pack that has no user-serviceable components within the battery pack.

Figure 6: BT128 Battery Pack

The rechargeable battery pack BT128 is shipped from the factory with a minimal charge and will need to be charged prior to use for the first time with the specified charger.

NOTE: When utilizing the optional tether mode on the XLTX transmitter, the battery packs will not be recharged from the tether power feed. The rechargeable battery pack only can be recharged using the specified charger.

When placing the battery pack into the XLTX battery pocket, orient the battery pack so that the sticker is facing out (see Figure 4).

After installing the battery pack, install the battery cover over the battery and secure by tightening the thumbscrew at the end of the battery cover (see Figure 5).

NOTE: For the battery level indicator on the XLTX display to display the correct battery level, the battery type dip switch settings need to be set for the battery pack being used. See section 3.1.4 for details on setting the battery type dip switches.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 13 of 40

3.1.3 Spare Battery Storage Compartment

The XLTX transmitter features a spare battery compartment to store a second battery pack. The second battery pack allows for quick replacement of the primary battery pack when the battery level gets low.

The spare battery storage compartment is the battery compartment with USB/IR cover inside the battery compartment.

USB/IR Cover is located in spare battery compartment

Compartment without

USB/IR cover is the primary battery compartment

Figure 7: Spare Battery Compartment Location

NOTE: The spare battery compartment features battery spring contacts like the primary battery compartment. These spring contacts in the spare battery compartment have no electrical connection and are used to secure the spare battery pack inside the compartment to prevent rattling.

3.1.4 Setting Battery Type Dip Switches

For proper indication of the battery level on the battery level indicator on the XLTX display, the battery type dip switch settings need to be set for the battery pack being used in the transmitter.

NOTE: The dip switch settings are set at the factory for the battery type ordered with the system.

These settings will only need to be changed if the battery type changes.

The dip switches are accessed through the USB/IR cover inside the spare battery compartment on the XLTX transmitter (see Figure 8).

Figure 8: USB/IR Cover Location and Cover Removal

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 14 of 40

Use the following table to properly set the dip switches for the correct battery type (see Figure 9 for dip switch view):

Battery P/N Battery Type

BT129-0 4.5V

Dip switch 1

Off

Dip switch 2

Off

Dip switch 3

Off

BT128-0 3.6V Off On Off

Figure 9: Dip switch block as viewed through USB/IR port

NOTE: The dip switch block switches are oriented that the off position is next to the number designator and the on position is up or away from the number designator.

3.2 TURNING THE TRANSMITTER ON AND OFF

The XLTX uses both a three position toggle switch labeled OFF-ON-START and a Machine Stop switch to turn the transmitter on or off.

Figure 10: Machine Stop Switch and OFF-ON-START toggle

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 15 of 40

3.2.1 Turning On the Transmitter

First, the Machine Stop switch must be in the raised position (pulled out). Next, push the OFF-

ON-START toggle switch to the START position and release it once the Magnetek logo appears on the LCD screen. Following the logo screen, the unit will perform a routine initialization.

During initialization, the XLTX scans for any switches or motions that may be on during power up.

If any switches or motions are on, the failure will be displayed on the screen, and then the XLTX will power itself down.

After a successful initialization, the XLTX will enter the Normal Operation Mode and display the normal operating screen. See Section 3.5 for more information on the Normal Operation Mode.

NOTE: Holding the OFF-ON-START toggle in the START position for more than 5 seconds will put the device into Setup Mode. For normal use release the START toggle once the Magnetek logo appears. See Section 4.0 for more information on the Setup Mode.

3.2.2 Pulling In the Machine Stop Relay

Once the XLTX has been turned on (as described in Section 3.2.1) and in the Normal Operating

Mode, the Machine Stop relay in the receiver can be pulled in by pushing the OFF-ON-START toggle switch to the START position and then releasing.

NOTE: You must release the OFF-ON-START switch to the ON position after the unit is powered up, then push to the START position a second time to pull in the Machine Stop relay.

3.2.3 Turning Off the Transmitter

The transmitter can be turned off by pressing the OFF-ON-START toggle switch down to the OFF position. Once turned off, the MLC relay in the receiver is immediately opened.

NOTE: Depressing the Machine Stop switch will also turn the transmitter off and open the

Machine Stop relay in the receiver. See Section 3.3 for more information on the Machine Stop switch.

3.3 MACHINE STOP SWITCH (For Emergency Stopping Only)

When depressed, the Machine Stop relay in the receiver is immediately opened.

Under normal operating conditions, the Machine Stop switch must be in the raised position or the transmitter and system will not operate.

NOTE: The Machine Stop Switch is to be used for emergency stopping only, not for normal system shut down.

3.4 GRAPHIC USER INTERFACE

The LCD screen located at the center of the device is an integral part of the XLTX transmitter. It is used to change configuration settings, confirm commands being operated, provide two-way feedback, and display transmitter diagnostic information such as battery life and signal strength.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 16 of 40

3.5 NORMAL OPERATING MODE

In normal operating mode, the XLTX displays real time information relating to the operation of the transmitter on the XLTX graphic user interface. Information may include Command Confirmation,

Battery Life, Signal Strength, Two-Way Feedback, etc.

Figure 11: Normal operating screen on XLTX graphic user interface

3.5.1 Watch Dog Indicator (Spinning Arrow)

The spinning arrow represents the watch dog timer within the CPU of the unit.

NOTE: The arrow should be continuously spinning at all times. If the arrow is not spinning the transmitter will need to be rebooted to operate properly.

Confirmation

Each time the user operates a control on the transmitter, a message will be displayed on the graphic user interface screen confirming what is being operated.

For example, if the second paddle is moved to its 4 th

position in the UP direction the display will show ‘MTN2 D1 SP=4’. This translates to ‘Motion 2, Direction 1, Speed 4’.

3.5.3 Battery Life Indicator

Remaining battery life is displayed in the bottom left hand corner of the graphic user interface screen.

Battery life is displayed in 5% increments.

NOTE: If using an optional battery pack from what the unit was shipped from the factory with, the battery life indicator will be inaccurate unless the dip switch settings are set to the correct battery type being used. See Section 3.1.4 for details to properly set the dip switches.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 17 of 40

3.5.4 Signal Strength Indicator

The Signal Strength Indicator is only available in systems equipped for Two-Way feedback

(systems utilizing the 433 MHz frequency band do not have Two-Way feedback available). For such systems, Signal Strength is displayed at the bottom right hand corner of the graphic user interface screen.

Signal Strength is displayed in 5% increments.

NOTE: On 433MHz systems, the signal strength indicator will show minimum signal strength regardless of the actual signal strength (systems utilizing the 433 MHz frequency band do not have Two-Way feedback).

3.5.5 Two-Way Feedback System

This option allows the user to view various parameters that may be important to the operation of the equipment on the graphic user interface display screen.

Parameters such as engine RPM, the torque or speed of a drive, temperature, current, or any other useful values can be sent from the receiver and displayed on the transmitter.

NOTE: Systems utilizing the 433 MHz frequency band do NOT have Two-Way feedback available.

3.6 JOYSTICKS AND PADDLES/LEVERS

To activate the desired motor functions, operate the Joystick or Paddle/Lever that corresponds to the desired motion.

To activate higher speed functions for those transmitter models so equipped, operate the Joystick or Paddle/Lever further to activate the desired speed.

3.7 ROTARY SELECTOR SWITCH

The rotary selector switch can be used to select various modes of operation.

A rotary switch can have 2 to 12 positions to select from.

3.8 AUXILIARY

These switches activate special function relays that control items such as grab attachments, magnets, lights, and etc.

The auxiliary switches can be momentary or latched.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 18 of 40

4.0 USING THE TRANSMITTER IN SETUP MODE

The Setup Mode can be used to edit configuration settings such as: Access Code, Channel

Select, User Code, Transmitter Time Out, Backlight Time Out, Password Enable, Change

Password, and more. The settings can still be changed with the optional RCP software.

NOTE: No parameter changes will take effect until the user has selected ‘Save and Exit’ from the

Setup Mode.

4.1 ENTERING SETUP MODE

To enter the Setup Mode, first make sure the unit is OFF and the Machine Stop switch is raised.

Next, push the OFF-ON-START toggle switch to the START position and hold it in the START position for more than 5 seconds until the setup screen appears.

The user will see a prompt for a four digit password if the password feature is enabled. If no password is enabled, then the adjustments in Section 4.2 will be available with no further input required from the user.

Use the Joystick/Paddle to increase/decrease the value and toggle to the START position when finished. If the password is entered correctly, the device will enter Setup Mode. If it is entered incorrectly, the device will power down.

NOTE: The factory default password to get into the setup menu is 0000.

4.2 ADJUSTING SETTINGS IN SETUP MODE

To navigate through Setup Mode, the Joystick/Paddle designated (MTN 1) and OFF-ON-START switch are used. The Joystick/Paddle cycles through the menus and is also used to change parameters within the menus. Pushing the OFF-ON-START switch to the START position will toggle between the menu and its parameter(s). When adjusting larger values, the speed is dependent on how far the Joystick/Paddle is depressed.

NOTE: No parameter changes will take effect until the user has selected ‘Save and Exit’ from the

Setup Mode.

The Access Code determines which receiver will be controlled by the transmitter.

The Access Code in the XLTX transmitter must match the receiver Access Code or DIP switches.

If the Access Codes settings on the receiver and transmitter do not match, no communication will occur.

The Access Code is a 20-bit binary value with a decimal equivalent of 0 - 1048575. It will be displayed as binary or decimal depending on the application.

The Channel Select setting determines the frequency on which the XLTX is operating.

The user can select channels 1 through 32, which correspond to the frequencies in Sections 6.2 and 6.3.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 19 of 40

The User Code setting is a unique identifier that allows the user to select multiple modes when using the same channel. The receiver can be tuned to only ‘hear’ messages sent from a transmitter with the same user code.

This setting controls the amount of time that the transmitter can be inactive before it automatically shuts off.

The Timeout time can be set from 1 to 60 minutes.

When the unit times out, the transmitter will turn off.

Setting Timeout to 0 disables transmitter timeout.

WARNING

DO NOT ASSUME THE POWER IS OFF IN THE RECEIVER BECAUSE THE

TRANSMITTER IS TURNED OFF. FAILURE TO FOLLOW THIS WARNING COULD

RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT.

Timeout

Backlight timeout setting controls the amount of time that the backlight will stay on after a command is pressed before it automatically shuts off.

Backlight Timeout can be set from 1 to 30 seconds.

Setting Time-Out to 0 disables the backlight.

NOTE: Leaving the backlight on longer will decrease the battery run time and will require more frequent battery replacement (or recharges for optional rechargeable battery packs).

This setting enables or disables the requirement of entering a password into the transmitter to enter setup mode.

When the disabled setting is selected the user will go directly into setup mode without being prompted to enter a password.

Magnetek strongly recommends enabling the setup mode password setting to prevent unauthorized or accidental changes to parameters.

NOTE: the unit is shipped with the password requirement enabled and utilizing the factory default password.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 20 of 40

This allows the user to change the password needed to enter the setup mode.

The password must consist of 4 digits.

If the user does not wish to save any of the configuration changes made, the Exit Without Save option can be selected.

NOTE: None of the changes will be saved upon selection of this option. The transmitter will start up with the last saved configuration settings.

4.2.9 Exit With Save

Selection of this option saves all changes and exits the Setup Mode.

Upon exit, the device will start up with the new configuration settings.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 21 of 40

5.0 OPTIONAL PROGRAMMING WITH RCP

Using the optional RCP software makes programming of the XLTX easier and allows for settings to be saved for future reference.

WARNING

THE USE OF RCP (RADIO CONTROL PROGRAMMER) IS INTENDED FOR USE BY

AUTHORIZED PERSONS ONLY. CHANGES TO ANY RADIO DATA VALUE MAY LEAD TO

UNEXPECTED, UNDESIREABLE, OR UNSAFE OPERATION OF EQUIPMENT AND

FURTHERMORE MAY LEAD TO EQUIPMENT DAMAGE, PERSONAL INJURY, OR EVEN

DEATH. ALL EQUIPMENT OPERATORS AND/OR PERSONNEL SHOULD BE NOTIFIED OF

ANY RADIO DATA VALUE CHANGES THAT MAY AFFECT OPERATION.

5.1 ACCESS

The receiver and transmitter must be programmed with the same access code to properly communicate with each other.

WARNING

TWO OPERATIONAL TRANSMITTERS WITH THE SAME ACCESS CODES OPERATING AT

THE SAME TIME IS A DEFINITE SAFETY HAZARD. FAILURE TO FOLLOW THIS WARNING

COULD RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT.

5.2 CHANGING RECIEVER ACCESS CODES

Receiver Access Code Programming. For detailed instructions on setting parameters including access codes, see the “Programming” section of the applicable receiver manual.

WARNING

AFTER CHANGING THE ACCESS CODES ON THE TRANSMITTER, TEST THE UNIT BY

TURNING IT ON AND OFF NEAR THE APPROPRIATE RECEIVER. IF THE RECEIVER DOES

NOT RESPOND, DO NOT ACTIVATE A FUNCTION BUTTON! THE TRANSMITTER MAY HAVE

THE WRONG ACCESS CODE, WHICH COULD MOVE OTHER EQUIPMENT. RE-CHECK THE

ACCESS CODE IN THE TRANSMITTER AND RETEST. FAILURE TO FOLLOW THIS

WARNING COULD RESULT IN SERIOUS INJURY OR DEATH, AND DAMAGE TO

EQUIPMENT.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 22 of 40

WARNING

THE ACCESS CODES IN THE RECEIVER ARE UNIQUE AND FACTORY PRESET. DO NOT

CHANGE THESE ACCESS CODES UNLESS YOU ARE REPLACING AN EXISTING

RECEIVER AND ITS ACCESS CODE. CHANGING THIS CODE COULD MAKE IT COMMON

WITH ANOTHER RECEIVER ACCESS CODE, WHICH COULD MOVE OTHER EQUIPMENT.

NO TWO SYSTEMS IN ANY LOCATION SHOULD EVER HAVE THE SAME ACCESS CODES

INDEPENDENT OF THE FREQUENCY. FAILURE TO FOLLOW THIS WARNING COULD

RESULT IN SERIOUS INJURY OR DEATH, AND DAMAGE TO EQUIPMENT.

5.3 CONNECTING THE XLTX TO A COMPUTER

The XLTX transmitter contains circuits that permit communication with a computer system via

USB. The USB mini-B plug is located through the IR/USB port window as detailed in Section

3.1.3.

Figure 12: USB mini-B receptacle as viewed through USB/IR port

When plugging in the transmitter to a computer system, the transmitter batteries must be installed. The USB circuit does not provide power to the transmitter. Magnetek highly recommends using a fully charged battery pack when using USB and RCP with the transmitter.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 23 of 40

5.4 PROGRAMMING WITH RCP

Read the section of the XLTX manual regarding additional operational features to familiarize you with the features listed below. The XLTX transmitter can be programmed using the optional RCP

(Radio Control Programmer) software.

Magnetek RCP software makes the programming of the XLTX transmitter easier and allows the programmer to store all of the XLTX settings in files for later use or reference. The RCP software also allows the programmer to customize the XLTX transmitter display with language descriptions that are project- or machine-specific. Help is provided for each function at the bottom of the RCP screen. The RCP software allows you to select frequency, access code, transmitter power, as well as CAN configuration. Follow the steps below:

Install the RCP Software

Install the RCP software onto your computer. The software is self installing; simply insert the CD-

ROM into your CD-ROM drive and follow the onscreen prompts. Refer to the installation instruction sheet for help. You will be prompted to enter an activation code. The code can be found on the CD jewel case and on the installation instructions. The software cannot be used without this code.

Run the RCP Software

After installation of the RCP Software, double click the RCP icon to launch the program.

Click on New Project or Open Project

Select “New Project” if you are creating a new program file. Select “Open Project” if you want to retrieve an existing program file. A list of recent projects will appear under “Open Project.”

Clicking on one of these will open that project. It is recommended that you create a folder in which to save all programming files.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 24 of 40

For New Projects, Select Device Type

After the New Projects icon is selected, a menu will open listing the available device types.

Select the device type that matches the product you wish to program (selecting a project type will display a picture of the product for verification).

Receive Device Data Checkbox

At the bottom of the New Project window there is a check box that allows the user to automatically download the setting values on the device upon connection.

NOTE: This check box is checked by default.

Having the “Receive Device Data” option checked will cause the program to automatically read the data that is currently on the device upon clicking the Add button.

WARNING

IF “RECEIVE DEVICE DATA” CHECKBOX IS UNCHECKED, THE RCP PROGRAM WILL

OVERWRITE ALL SETTING VALUES ON THE DEVICE WITH DEFAULT VALUES AND ANY

SETTINGS CHANGED BY THE OPERATOR UPON SENDING THE PROGRAM TO THE

DEVICE. ALL STORED VALUE SETTINGS WITHIN THE DEVICE WILL BE REPLACED,

INCLUDING ANY PROJECT-SPECIFIC VALUES. MAGNETEK STRONGLY RECOMMENDS

THAT THE “RECEIVE DEVICE DATA” CHECKBOX BE LEFT CHECKED.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 25 of 40

This screen also allows the programmer to create a specific name for the device to help keep track of device settings and changes. It is recommended that a unique name is chosen for each device programmed with RCP.

5.4.1 XLTX Configuration Pages

The XLTX Transmitter has two configurable pages available to change settings on. The first page allows the configuration of general transmitter settings (Transmitter name, Access code, RF channel, etc.). The second page allows the configuration of the CAN bus network settings for models with the optional CAN connector equipped.

Unit Info Pages

This page allows the user to view the receiver’s Project ID and serial number. The user can modify the transmitter name, access code, RF channel and activate the password. This page may also be used by the user to synchronize the internal clock on the transmitter with the connected PC or manually set the clock/date.

NOTE: Changing any of these details will require a reboot of the XLTX after the new information has been sent to the device.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 26 of 40

Transmitter Name

The transmitter name field allows the user to create a custom name for the transmitter. The name can be up to 16 ASCII characters long.

Project ID

This section displays the Project ID for the unit. The Project ID is set by the factory and cannot be modified by the user.

Serial Number

This section displays the serial number for the unit. The serial number of the unit is set by the factory and cannot be modified by the user.

Access Code

The access code acts as the transmitter address. The transmitter will only transmit commands to receivers with the same address. This feature is selectable by the user.

NOTE: The transmitter must be set with the same access code as the receiver to properly communicate with each other.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 27 of 40

WARNING

THE ACCESS CODES IN THE RECEIVER ARE UNIQUE AND FACTORY PRESET. DO NOT

CHANGE THESE ACCESS CODES UNLESS YOU ARE REPLACING AN EXISTING

RECEIVER AND ITS ACCESS CODE. CHANGING THIS CODE COULD MAKE IT COMMON

WITH ANOTHER RECEIVER ACCESS CODE, WHICH COULD MOVE OTHER EQUIPMENT.

NO TWO SYSTEMS IN ANY LOCATION SHOULD EVER HAVE THE SAME ACCESS CODES

INDEPENDENT OF FREQUENCY. FAILURE TO FOLLOW THIS WARNING COULD RESULT

IN SERIOUS INJURY OR DEATH, AND DAMAGE TO EQUIPMENT.

RF Channel

The RF channel is user-selectable through the pull-down menu. This function is used to prevent interference with other radio devices. The user-selectable channels for 400MHz, 900MHz and

2.4GHz systems are 1 through 32. See Sections 6.2 and 6.3 for channel frequency details.

Inactivity Timeout

The transmitter can be set to turn off after a period of time when no controls are activated. To restart the transmitter, the OFF-ON-START switch must be cycled through the start position. The factory default setting for the inactivity timeout is 15 minutes.

RF Power

The RF transmitting power of the unit is user-selectable through the pull-down menu. This function is used to reduce the operating range of the transmitter from the equipment being operated. The user-selectable options for RF power are Full, Half, Quarter and Minimum.

Activate Password

The password is used to restrict access to the configuration menu on the XLTX. Having an active password prevents accidental changes to the transmitter.

Please familiarize yourself with this section before programming your password.

If you choose to enable the password function, you can create a new password by selecting a four digit numerical password using numbers from 0 to 9. Be sure to write this password down in a safe place for future reference.

WARNING

ALWAYS REMEMBER TO STORE THE PASSWORD IN A SECURE LOCATION FOR ACCESS

IF THE PASSWORD IS LOST OR FORGOTTEN. ONCE THE TRANSMITTER IS

PROGRAMMED WITH A PASSWORD, THERE IS NO WAY TO DEFEAT THE PASSWORD

WITHOUT USING THE RCP SOFTWARE TO EITHER READ THE PASSWORD OR

REPROGRAM A NEW PASSWORD.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 28 of 40

WARNING

THIS PASSWORD FUNCTION IS NOT TO BE USED AS A SECURITY DEVICE. THE

PURPOSE OF THIS FUNCTION IS TO PREVENT ACCIDENTAL CHANGES TO THE

TRANSMITTER SETTINGS. THE BEST FORM OF SECURITY IS ALWAYS TO LOCK UP THE

TRANSMITTER WHEN NOT IN SERVICE. FAILURE TO FOLLOW THIS WARNING COULD

RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT.

The password default setting is to be disabled during initial programming by the RCP software.

To enable password protection, check the box next to the phase “Activate password.”

WARNING

NOT ENABLING THE PASSWORD FUNCTION ALLOWS THE TRANSMITTER SETTINGS TO

BE MODIFIED BY ANY UNAUTHORIZED USERS. IMPROPER TRANSMITTER SETTINGS

COULD RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT.

Backlight Enable

This section allows the user to enable the LCD display backlight (on systems equipped with optional graphic user interface LCD display) and select the period of time after transmitter activity that the backlight stays on.

The user has the option to check the “Always On” check boxed for backlight timeout. If this box is checked, the backlight will remain on continuously while the transmitter is active.

NOTE: The longer the backlight is turned on, the shorter the transmitter battery life will be.

The user can also enable the backlight to turn off or timeout after a period of time - the user can select the custom field and enter in the time (in seconds) that the backlight should be lit. The range of values is 1 to 30 seconds.

Update Transmitter Date/Time

This feature allows the user to reset the internal clock on the transmitter to the correct date and time. The user can select to match the clock on the PC that is connected to the unit or select a custom date and time.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 29 of 40

CAN Configuration Page

This page allows the user to modify the CAN bus network communication settings.

Source Address

This is the address that the XLTX will use as the source address when transmitting messages on the CAN bus network.

Protocol

This pull down menu allows the user to modify the communication protocol for the CAN bus network. The user can select from the following options:

 J1939

 CAN

 Parker

 High Country Tek DN

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 30 of 40

Baud Rate

This pull down menu allows the user to modify the communication speed of the CAN bus network. The user selectable options are 50k, 125k, 250k and 500k.

Identifier

This pull down menu allows the user to select between an 11 bits or 29 bits identifier.

5.4.2 Saving, Downloading, and Reading the Programs and Other RCP Software

Functions

CAUTION

TO PROGRAM OR READ DATA FROM THE XLTX, THE TRANSMITTER MUST BE TURNED

ON.

Saving the Programming File

Once programming is complete click the file tab at the top of the RCP screen to open the file menu. File locations and names can be selected from this menu. Old files can be deleted, called up, modified and renamed by this same menu.

Sending a Program to the XLTX

WARNING

AFTER EVERY PROGRAMMING OF THE TRANSMITTER, TEST THE UNIT BY UTILIZING

THE APPROPRIATE RECEIVER. IF THE RECEIVER DOES NOT RESPOND, DO NOT

ACTIVATE A FUNCTION BUTTON! THE TRANSMITTER MAY HAVE INCORRECT

PROGRAMMING. RE-CHECK THE PROGRAMMING IN THE TRANSMITTER AND RETEST.

AFTER ACTIVATION OF THE RECEIVER, FUNCTIONALLY TEST ALL COMMANDS ON THE

TRANSMITTER BY INITIALLY JOGGING THE BUTTONS, THEN WITH A FULL MOVEMENT

BEFORE RETURNING TO SERVICE. FAILURE TO FOLLOW THIS WARNING COULD

RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT.

To send a program file to a XLTX Transmitter

1. Plug in the USB programming cable or position.

2. Click the “send” button on the RCP screen. A dialog box will pop up confirming that you want to proceed. Check the box marked “I accept,” and then click the button “Continue send to radio.” On-screen prompts will confirm that the receiver has been programmed or if there are any issues.

3. Data will need to be sent separately for the Unit Info and CAN Configuration screens.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 31 of 40

Receiving (Reading) the XLTX Programming

To read a program file from the XLTX Transmitter:

1. Plug in the USB programming cable.

2. Click “Receive” and follow on-screen prompts.

3. RCP will confirm reception and automatically display current programming in the XLTX unit.

Reading the RCP Software Version

“Help”.

“About”.

3. The RCP Software Version number will be displayed.

Resetting XLTX Back to Factory Default Settings

1. Select “Reset to Defaults” button.

2. A dialog box will pop up confirming that you want to proceed. Click the button “OK” to restore the factory default settings. On-screen prompts will confirm that the transmitter has been reset to defaults or if there are any issues.

3. Power cycle the XLTX transmitter to implement the factory default values.

NOTE: Resetting the system back to factory defaults only restores the factory settings for the

CAN configuration settings. All other settings will not be altered.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 32 of 40

6.0 TRANSMITTER CHANNEL CONFIGURATION SETTINGS

The RF channel can be set via the setup mode or the optional RCP software. Sections 6.2 and

6.3 show the channels and protocols available for each transmitter radio frequency option.

6.1 FCC STATEMENTS

Compliance Statement (Part 15.19)

This device complies with Part 15 of FCC rules.

Operation is subject to the following two conditions:

1. This device may not cause harmful interference, and

2. This device must accept any interference received, including interference that may cause undesired operation.

Warning (Part 15.21)

Changes or modifications not expressly approved by the party responsible for compliance should void the user’s authority to operate the equipment.

This portable transmitter with its antenna complies with FCC’s RF exposure limits for general population/uncontrolled exposure.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 33 of 40

6.2 CHANNEL AND FREQUENCY DESIGNATIONS BY COUNT

433 MHz: TMS and TDMA

Channel Channel Actual

Count Designator

01) 01

02) 02

03) 03

MHz

433.050

MHz

04) 04

05) 05

06) 06

07) 07

08) 08

09) 09

10) 10

MHz

MHz

MHz

MHz

433.450

11) 11

12) 12

13) 13

14) 14

15) 15

16) 16

17) 17

18) 18

19) 19

20) 20

21) 21

22) 22

23) 23

24) 24

25) 25

26) 26

27) 27

MHz

433.600

MHz

433.700

MHz

MHz

MHz

434.000

MHz

434.100

MHz

MHz

434.300

28) 28

29) 29

30) 30

31) 31

32) 32

1.A

MHz

MHz

900 MHz: TMS and TDMA

Channel Channel Actual

Count Designator

01) 1

02) 2

03) 3

MHz

906.30 MHz

907.80 MHz

04) 4

05) 5

06) 6

07) 7

08) 8

09) A

10) B

909.30 MHz

912.30 MHz

915.30 MHz

919.80 MHz

921.30 MHz

902.30 MHz

904.10 MHz

11) C

12) D

13) E

14) F

15) G

16) H

17) I

18) J

19) K

20) L

21) M

22) N

23) O

24) P

25) Q

26) R

27) S

904.30 MHz

905.10 MHz

905.50 MHz

905.70 MHz

906.60 MHz

908.70 MHz

908.90 MHz

909.10 MHz

910.10 MHz

910.70 MHz

911.00 MHz

911.20 MHz

912.00 MHz

914.20 MHz

914.40 MHz

914.60 MHz

914.80 MHz

28) T

29) U

30) V

915.80 MHz

917.40 MHz

923.20 MHz

31) W

32) X

927.00 MHz

927.30 MHz

1.B

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 34 of 40

6.3 OPTIONAL FREQUENCIES AND CHANNELS

6.3.1 900 MHz: FHSS

Channel sets are designated between 1 and 32. The frequency range is between 902-928 MHz.

The frequency hopping protocol does not use one particular frequency to transmit a message.

Messages are transmitted over multiple frequencies in a predefined sequence or channel set. In doing so, this protocol is able to compensate for interference that may be present on a single frequency by sending the message across multiple frequencies.

6.3.2 2.4 GHz: FHSS

Channel sets are designated between 1 and 32. The frequency range is between 2402-2478

MHz. The frequency hopping protocol does not use one particular frequency to transmit a message. Messages are transmitted over multiple frequencies in a predefined sequence or channel set. In doing so, this protocol is able to compensate for interference that may be present on a single frequency by sending the message across multiple frequencies.

6.3.3 433 MHz Telemotive Legacy Channel Set: TMS and TDMA

Channel Channel Actual

Frequency

01) AK01

02) AK02

03) AK03

04) AK04

05) AK05

06) AK06

07) AK07

08) AK08

09) AK09

10) AK10

11) AK11

12) AK12

13) AK13

14) AK14

15) AK15

16) AK16

17) AK17

18) AK18

19) AK19

20) AK20

21) AKA00

MHz

MHz

22) AKA01 433.325

23) AKA02 433.525

24) AKA03 433.725

25) AKA04 433.925

26) AKA05 434.125

27) AKA06 434.325

28) AKA07 434.525

29) AKA08 434.725

30) AK38

31) AK50

Table 2

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 35 of 40

7.0 OPTIONAL CAN BUS TETHER FEATURE

The XLTX transmitter can be ordered with an optional CAN bus tether feature. This feature allows for the operation of the transmitter as a wired transmitter with no wireless radio transmission. If the XLTX transmitter was ordered with the CAN bus tether feature, this section applies to features and operation of the transmitter in tether mode.

7.1 INSTALLATION OF TETHER CABLE

The tether cable is attached to the CAN connector on the transmitter by lining up the alignment groove and inserting the plug into the CAN connector receptacle. Twist the locking ring on the

CAN plug clockwise to tighten it down and prevent accidental disengagement.

7.2 OPERATION OF TRANSMITTER IN TETHER MODE

With the tether cable attached, turn on the transmitter following the start up sequence as outlined in Section 3.2.

During the start-up sequence the transmitter will automatically recognize that the tether cable is attached and communicating and switch into tether mode. Tether mode turns off the wireless transmitter and sends all command signals through the tether cable.

Visual verification of the transmitter being in tether mode can be observed on the graphic user interface screen.

NOTE: The transmitter must go through the start up initialization sequence with the tether cable attached to activate tether mode.

All controls on the transmitter will function the same regardless of whether the transmitter is in tether mode or wireless mode.

NOTE: While the tether cable provides power to the transmitter when connected, it will not recharge batteries in the transmitter. To recharge batteries, you must only use the Magnetek

Enrange approved chargers for the appropriate battery pack.

7.3 RETURNING TRANSMITTER TO WIRELESS MODE

To return the transmitter to wireless mode, power down the unit and disconnect the tether cable.

Following the start-up sequence from Section 3.2, restart the transmitter. The transmitter will automatically sense that it is no longer connected to the tether cable and start the unit in its normal wireless mode.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 36 of 40

7.4 CAN CONNECTOR RECEPTACLE PIN-OUT DETAILS

The CAN connector receptacle located on the transmitter has specific pin assignments. It is very critical that these pin assignments are matched in the CAN cable assembly.

2

Keyway

3

4

5

1

Figure 13: CAN Connector Pin Out details

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 37 of 40

8.0 GENERAL TROUBLESHOOTING

Suggestions

Transmitter will not turn on

Batteries are dead or installed backwards; battery holder is damaged.

Transmitter is failing switch scan

Replace the batteries and confirm they are installed according to the polarity marking in the battery pack. Inspect all battery pack contacts for damage. When installing the battery pack into the XLTX, confirm it is installed with the label facing out. Confirm battery pack is installed in the primary battery compartment and not in the spare compartment.

Be sure all switches and motions are in the off position on startup. See Section 3.2 for more info.

Transmitter Machine Stop

Switch is down or pressed

Be sure the Machine Stop switch is pulled up.

Incorrect system RF channel

Incorrect system access code

Make sure the transmitter and receiver unit are both set to the same RF channel. See Section

4.2.2.

Make sure the transmitter and receiver both have the same access code. Sec Section

4.2.1.

Transmitter will not respond with the receiver

System out of range

Make sure that the startup procedure is initiated within 300 feet from the receiver location. If equipped with the Signal Strength

Indicator, make sure the level is greater than

0%.

The antenna on the receiver is missing, damaged, or improperly installed.

Inspect the antenna on the receiver for damage and try to locate the antenna in a location that is visible when operating the equipment at all times.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 38 of 40

8.1 TROUBLESHOOTING: OPTIONAL TETHER OPERATION

Suggestions

Transmitter will not turn on

Connecting tether cable is not installed, installed improperly, or is damaged.

Transmitter is failing switch scan

Inspect the tether cable and confirm that it is installed and secured correctly. Inspect all connectors, connector contacts and cable jacket for damage.

Be sure all switches and motions are in the off position on startup. See Section 3.2 for more info.

Transmitter machine stop switch is down or pressed

Be sure the Machine Stop switch is pulled up.

System not in tether mode

Transmitter will not respond with the receiver in Tether mode

The tether cable or connectors are damaged

Make sure that the start-up procedure is initiated with the tether cable attached. Ensure that all tether cable connections are secure prior to startup.

Inspect the tether cable and connectors for damage.

Transmitter will not respond with the receiver in wireless mode

CAN settings are incorrect

System not in wireless mode

Verify CAN settings match project specific CAN bus document

Make sure that the startup procedure is initiated with the tether cable detached.

Ensure that the start-up procedure is initiated within 300 feet from the receiver location.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 39 of 40

8.2 ASSEMBLY AND REPLACEMENT PARTS

If your transmitter ever needs repair, we always recommend that you have Magnetek perform the repair. If you need to refer to a parts list, refer to the transmitter drawing that was included in the shipment of your transmitter. Please contact Magnetek’s service department at

1.866.MAG.SERV for information regarding parts and service.

Enrange Engineered XLTX Transmitter Instruction Manual

April 2011

Page 40 of 40

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement

Table of contents