QA6ADP QA
Conversion Adapter
Module
User's Manual
QA6ADP
Thank you for purchasing the Mitsubishi programmable controller
MELSEC-Q series.
Prior to use, please read this and relevant manuals thorougly to fully
understand the product.
MODEL
QA6ADP-U-JE
MODEL
13JY50
CODE
IB(NA)-0800402-G(1405)MEE
© 2007 MITSUBISHI ELECTRIC CORPORATION
CONDITIONS OF USE FOR THE PRODUCT
(1) Mitsubishi programmable controller ("the PRODUCT") shall be used in
conditions;
i) where any problem, fault or failure occurring in the PRODUCT, if any,
shall not lead to any major or serious accident; and
ii) where the backup and fail-safe function are systematically or
automatically provided outside of the PRODUCT for the case of any
problem, fault or failure occurring in the PRODUCT.
(2) The PRODUCT has been designed and manufactured for the purpose of
being used in general industries.
MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY
(INCLUDING, BUT NOT LIMITED TO ANY AND ALL RESPONSIBILITY
OR LIABILITY BASED ON CONTRACT, WARRANTY, TORT, PRODUCT
LIABILITY) FOR ANY INJURY OR DEATH TO PERSONS OR LOSS OR
DAMAGE TO PROPERTY CAUSED BY the PRODUCT THAT ARE
OPERATED OR USED IN APPLICATION NOT INTENDED OR
EXCLUDED BY INSTRUCTIONS, PRECAUTIONS, OR WARNING
CONTAINED IN MITSUBISHI'S USER, INSTRUCTION AND/OR
SAFETY MANUALS, TECHNICAL BULLETINS AND GUIDELINES FOR
the PRODUCT.
("Prohibited Application")
Prohibited Applications include, but not limited to, the use of the
PRODUCT in;
• Nuclear Power Plants and any other power plants operated by Power
companies, and/or any other cases in which the public could be
affected if any problem or fault occurs in the PRODUCT.
• Railway companies or Public service purposes, and/or any other cases
in which establishment of a special quality assurance system is
required by the Purchaser or End User.
• Aircraft or Aerospace, Medical applications, Train equipment, transport
equipment such as Elevator and Escalator, Incineration and Fuel
devices, Vehicles, Manned transportation, Equipment for Recreation
and Amusement, and Safety devices, handling of Nuclear or
Hazardous Materials or Chemicals, Mining and Drilling, and/or other
applications where there is a significant risk of injury to the public or
property.
A-1
Notwithstanding the above, restrictions Mitsubishi may in its sole
discretion, authorize use of the PRODUCT in one or more of the
Prohibited Applications, provided that the usage of the PRODUCT is
limited only for the specific applications agreed to by Mitsubishi and
provided further that no special quality assurance or fail-safe, redundant
or other safety features which exceed the general specifications of the
PRODUCTs are required. For details, please contact the Mitsubishi
representative in your region.
A-2
REVISIONS
* The manual number is noted at the lower right of the top cover.
Print Date
Aug., 2007
Mar., 2008
*Manual Number
IB(NA)-0800402-A
IB(NA)-0800402-B
Mar., 2010
IB(NA)-0800402-C
Apr., 2010
IB(NA)-0800402-D
Mar., 2011
IB(NA)-0800402-E
Oct., 2011
IB(NA)-0800402-F
May, 2014
IB(NA)-0800402-G
Revision
First printing
Partial correction
Section 2.2, 6.1
Partial correction
Section 2.2
Addition
CONDITIONS OF USE FOR THE PRODUCT
Partial correction
Back cover
Partial correction
Section6.2
Partial correction
Section2.1
Partial correction
Section3.1
This manual confers no industrial property rights or any rights of any other kind, nor does it
confer any patent licenses. Mitsubishi electric Corporation cannot be held responsible for any
problems involving industrial property rights which may occur as a result of using the contents
noted in this manual
 2007 MITSUBISHI ELECTRIC CORPORATION
A-3
CONTENTS
1. OVERVIEW .................................................................................................... 1
1.1 Overview................................................................................................... 1
1.2 Included Parts........................................................................................... 2
2. SYSTEM CONFIGURATION ......................................................................... 3
2.1 System Configuration ............................................................................... 3
2.2 Configuration Device List.......................................................................... 5
3. SPECIFICATIONS .......................................................................................... 8
3.1 General Specifications.............................................................................. 8
3.2 Performance Specifications ...................................................................... 9
4. PART NAMES AND SETTING ..................................................................... 10
4.1 Part Names............................................................................................. 10
4.2 Extension Stage Number Setting ........................................................... 11
5. MOUNTING AND INSTALLATION ............................................................... 12
5.1 Mounting/Removal of QA6ADP .............................................................. 12
5.2 Connection/Disconnection of Extension Cable....................................... 14
6. PRECAUTION FOR USING QA6ADP.......................................................... 17
6.1 Current Consumption of QA6ADP .......................................................... 17
6.2 Voltage Drop of Extension Cable ........................................................... 18
7. COMPATIBLE MODELS LIST ...................................................................... 20
GENERIC TERMS AND ABBREVIATIONS
Unless otherwise specified, this manual uses the following generic
terms and abbreviations to explain the QA conversion adapter module.
Generic term/Abbreviation
A5B
A6B
QA6ADP
QA6ADP+A5B/A6B
Description
Generic term for A52B, A55B, and A58B extension base
units on which A series I/O module and special function
module can be mounted without power supply.
Generic term for A62B, A65B, and A68B extension base
units on which A series I/O module and special function
module can be mounted.
Abbreviation for QA6ADP QA conversion adapter module.
Abbreviation for A large type extension base unit on which
QA6ADP is mounted.
A-4
1. OVERVIEW
1.1 Overview
This user’s manual describes the specifications, configuration device,
part names and setting, and implementation and installation of the
QA6ADP QA conversion adapter module.
For contents that are not described in this manual such as safety
precautions, EMC and low voltage directives, or error code list, refer to
QCPU User’s Manual (Hardware Design, Maintenance and Inspection)
(SH-080483).
The QA6ADP is the adapter module connecting the A (large type)
series extension base unit to the Q series main base unit.
Q3B
A3B
Replace CPU
with QCPU
QA6B
Replace the main base unit (A3B)
with the extension base unit (QA6B)
A6B
A6B
Mount the QA6ADP on the
extension base unit (A6B)
QA6ADP
POINT
• The QA6ADP is CE-compliant. To meet the EMC directive, the extension base unit and
module to be used in combination with the QA6ADP should be CE-compliant.
• When using a control line or communication cable, keep it away from the main circuit or
power line 100mm or more.
Failure to do so may cause malfunction due to noise.
1
1.2 Included Parts
This section describes parts included with this module.
Product name
QA6ADP QA conversion adapter module
Adapter module mounting bracket
Mounting bracket fixing screw
Board fixing screw
This manual
Model
QA6ADP




2
Quantity
1
1
1
1
1
Remarks





2. SYSTEM CONFIGURATION
2.1 System Configuration
This section describes the system configuration and restrictions when
the QA6ADP is used.
(1) The QA6ADP+A5B/A6B is only applicable for the following
CPU modules.
• High Performance model QCPU
• Universal model QCPU whose serial number (first five digits) is
"13102" or later
(2) Mount the Q5B/Q6B, QA6B, and QA6ADP+A5B/A6B in
order from the nearest position of the main base unit.
The QA6ADP cannot be used in combination with the QA1S5B or
QA1S6B.
(3) The number of slots of the QA6ADP+A5B/A6B is always
displayed in 8 slots, regardless of the number of slots of the
extension base unit to be used in combination with the QA6ADP.
Assign the I/O number of a module, putting each series in block
and in order of "Q seriesA series" or "A seriesQ series".
Failure to do so may cause an error (SP.UNITLAY ERR).
In addition, do not duplicate the I/O number.
(4) For the extension stage number setting of the extension base unit,
set stage number (the first to seventh stages) to extension stages
from the one nearest to the main base unit.
(5) An extension cable connectable to the QA6ADP is the Q series
extension cable only.
(6) Set the same stage number to both the stage number setting
connector of the extension base unit and that of the QA6ADP.
(7) The QA6ADP+A5B/A6B cannot be used as the MELSECNET/
H remote I/O station.
3
(8) The bus connection with GOT is not available for the
QA6ADP+A5B/A6B.
Power
supply
[Extension stage number setting]
Stage number setting connector
CPU module
0 1 2 3 4 5 6 7
.........Q38B
8
9 10 11 12 13 14 15
Power
supply
1
Main base unit
..............Q68B
Q series compatible extension base unit
(The Q5B/Q6B is connected to the
main base unit or the Q5B/Q6B.)
Power
supply
16 17 18 19 20 21 22 23
2
...QA68B
A series compatible extension base unit
(The QA6B is connected to the main
base unit, the end of the Q5B/Q6B,
or the QA6B.)
......A68B
A series compatible extension base unit
(The QA6ADP+A5B/A6B is connected
to the main base unit, the end of the
Q5B/Q6B/QA6B, or the QA6ADP
+A5B/A6B.)
3
Power
supply
24 25 26 27 28 29 30 31
QA6ADP
4
2.2 Configuration Device List
(1) Extension base unit mountable on the QA6ADP
The following shows extension base units that can be mounted on
the QA6ADP.
Product name
Extension base unit
(Power supply module not
mounting type)
Extension base unit
(Power supply module
mounting type)
A52B,
A55B-UL,
Model
A55B,
A58B-UL
A62B,
A65B-UL,
A65B,
A68B-UL
Remarks
A58B,
A68B,


(2) Module mountable on the extension base unit where the QA6ADP
is mounted
The following shows modules that can be mounted on the
extension base unit where the QA6ADP is mounted.
Product name
Power supply module
Power supply module
(I/O slot mounting type)
AC input module
AC/DC input module
DC input module
Contact output module
Triac output module
Transistor output module
Dynamic I/O module
Combined I/O module
Model
A61PN,
A61PEU,
A61P,
A63P,
A68P
Remarks
A62P,
A62PEU


AX10,
AX20,
AX31,
AX40,
AX42,
AX60-S1,
AX80,
AX81-S1,
AX81B,
AY10,
AY11A,
AY11EEU,
AY13EU,
AY22,
AY40,
AY42,
AY42-S3,
AY51,
AY60S,
AY71,
AY81,
A42XY
AH42
AX11,
AX21,
AX31-S1
AX41,
AX42-S1,
AX70,
AX80E,
AX81-S2,
AX82
AY10A,
AY11E,
AY13,
AY15EU
AY23
AY40A,
AY42-S1,
AY42-S4,
AY51-S1,
AY60E,
AY72,
AY82EP
AX11EU,
AX21EU
*6

AX41-S1,
AX50-S1,
AX71,
AX81,
AX81-S3,
AY11,
AY11AEU,
AY13E,



AY41,
AY42-S2,
AY50,
AY60,
AY70,
AY80,



5
Product name
High-speed counter module
A/D converter module
D/A converter module
Temperature-digital converter
module
Interrupt module
Positioning module
A-A1S module conversion
adapter
MELSECNET/MINI-S3 master
module
Intelligent communication
module
PC fault detection module
MELSEC-I/OLINK module
B/NET interface module
Blank cover
Dummy module
AD61,
A68AD,
A616AD
A62DA,
A68DAI-S1,
A68RD3,
A68RD4N,
A60MXR,
A60MXTN
AI61,
AD70,
AD71S1,
AD72
AD75M1,
AD75P1-S3,
A1ADP-XY,
Model
AD61S1
A68AD-S2,
A68ADN,

A62DA-S1,
A616DAV,
A68RD3N,
A616TD,
A60MXRN,
A68DAV,
A616DAI
A68RD4,
A60MX,
A60MXT,

AI61-S1
AD70D,
AD71S2,
AD71,
AD71S7,
AD75M2,
AD75P2-S3,
A1ADP-SP
AJ71PT32-S3,
AJ71T32-S3
AD51,
AD51E,
AD51E-S3,
AD51H,
AS91
AJ51T64
AJ71B62-S3
AG60
AG62
6
Remarks
*1

*2
AD75M3,
AD75P3-S3

*1
*3 *4
*1
AD51-S3,
AD51H-S3
*2





*1
*2
The dedicated instructions used in the QnA/A series program cannot be used
in the QCPU.
Replace the dedicated instructions with the FROM/TO instructions.
There is restriction on the number of mountable modules.
Product name
Intelligent communication
module
Interrupt module
*3
*4
*5
*6
Model
AD51,
AD51-S3,
AD51H,
AI61,
AD51E,
AD51E-S3,
AD51H-S3
AI61-S1
No. of mountable
modules
6
1 *5
Using the A-A1S module conversion adapter enables to use modules
equivalent to the AnS module by the module shown in the table. For the
mountable modules, refer to A-A1S Module Conversion Adapter User's
Manual (IB-0800352).
Only the multidrop link function can be used with the A1SJ71UC24R4+A1ADP.
The interrupt module can use only one out of the QI60 (when mounted on the
Q3B, Q5B or Q6B), AI61, and AI61-S1.
The normal operation of A series AC input module can be guaranteed only
when the base unit on which the A series power supply module is mounted
exists in the system.
Make sure that the following condition is satisfied when A series AC input
module is used.
 A series AC input module is mounted on the QA6B or QA6ADP+A6B.
 A series AC input module is mounted on the QA6ADP+A5B. However,
A series compatible extension base unit, QA6B or QA6ADP+A6B,
exists in the system.
7
3. SPECIFICATIONS
3.1 General Specifications
This section describes general specifications of the QA6ADP.
Item
Operating ambient
temperature
Température
ambiante de
fonctionnement
Storage ambient
temperature
Operating ambient
humidity
Storage ambient
humidity
Specifications
0 to 55 °C
0 à 55 °C
-20 to 75 °C
10 to 90 % RH, No-condensing
10 to 90 % RH, No-condensing
Accelera
Amplitude
-tion
10 to 57 Hz

0.075 mm
Frequency
Vibration
resistance
Shock resistance
Operation
ambiance
Operating
elevation *3
Installation location
Overvoltage
category *1
Pollution degree *2
Equipment
category
*1
Conforming
to
JIS B 3502,
IEC 61131-2
Sweep
count
Under
intermittent
10 times

57 to 150 Hz 9.8 m/s2
vibration
each in
00.35 mm X, Y, Z
Under
10 to 57 Hz

(0.001 in.) directions
continuous
vibration
57 to 150 Hz 4.9 m/s2

Conforming to JIS B 3502, IEC 61131-2
2
(147 m/s , 3 times in each of 3 directions XYZ)
No corrosive gasses
0 to 2000 m
Control panel
II max.
2 max.
Class I
This indicates the section of the power supply to which the equipment is
assumed to be connected between the public electrical power distribution
network and the machinery within premises.
Category II applies to equipment for which electrical power is supplied from
fixed facilities.
The surge voltage withstand level for up to the rated voltage of 300 V is 2500
V.
8
*2
*3
This index indicates the degree to which conductive material is generated in
terms of the environment in which the equipment is used.
Pollution level 2 is when only non-conductive pollution occurs. A temporary
conductivity caused by condensing must be expected occasionally.
Do not use or store the programmable controller in the environment when the
pressure is higher than the atmospheric pressure at sea level.
Otherwise, malfunction may result.
To use the programmable controller in high-pressure environment, please
contact your local Mitsubishi Repress entative.
3.2 Performance Specifications
This section describes performance specifications of the QA6ADP.
Item
Specifications
5VDC internal current
consumption
External dimensions *1
110 mA
130 mm (5.11 inch) (H) × 73.5 mm (2.89 inch) (W)
× 74 (2.91 inch) mm (D)
Weight
0.2 kg
Adapter mounting screw (M3)
torque
0.36 to 0.48 N•m
Board fixing screw torque
0.61 to 0.82 N•m
*1
The external dimensions show values in a status where the QA6ADP is
mounted on the extension base unit.
9
4. PART NAMES AND SETTING
4.1 Part Names
This section describes part names of the QA6ADP
.
9)
8)
3)
1)
7)
6)
4)
2)
5)
No.
1)
2)
3)
4)
5)
6)
7)
8)
9)
Name
Extension cable
connector
Stage number setting
connector
Adapter module
mounting screw
(M3 screw)
3)
Application
Connector for sending/receiving signals to the main base unit
or the other extension base unit and connecting an extension
cable.
Connector for setting the number of extension stages.
Screw for mounting this adapter module on the extension base
unit.
Bracket for mounting this adapter module on the extension
base unit. Utilize screws used in the extension base unit.
(Included parts)
Mounting bracket fixing Screw for mounting an adapter module mounting bracket on
screw
the extension base unit. (Included parts)
Base side stage
Window is transparent so that a stage number setting
number setting
connecter of the extension base unit side can be seen.
connector window
Extension base unit
Connector to be connected to the A extension cable I/O
mounting connector
connecter of the extension base unit.
Screw for mounting this adapter module on the extension base
Board fixing screw
unit. (Included parts)
Guide for positioning an extension base unit mounting
Mounting guide
connector by inserting this into a cover fixing square hole of the
extension base unit at the time of mounting.
Adapter module
mounting bracket
10
4.2 Extension Stage Number Setting
Set the number of extension stages to both the QA6ADP and the
extension base unit.
The same stage number should be set to both the stage number setting
connector of the extension base unit and that of the QA6ADP.
POINT
Set any number of 1 to 7 which matches to the number of extension stages for the stage
number setting connector setting. If the stage number setting of the QA6ADP and that of the
extension base unit is different, the two or more settings are made to one stage, the same
stage number is duplicated, or no setting is made to the number of stages, incorrect input or
incorrect output will occur.
(1) Extension stage number setting of the QA6ADP
The following describes how to set the number of extension stages
of the QA6ADP.
Extension stage number setting
1st stage 2nd stage 3rd stage 4th stage 5th stage 6th stage 7th stage
Stage number
setting connector
setting
(2) Extension stage number setting of the extension base unit
Remove a base cover from the
extension base unit.
Insert a connector pin into the place of
the stage number selected from 1 to 7
of the connector (CON3) at bottom left
of the base unit.
Completed
Stage number setting connector
Extension stage number setting
1st stage 2nd stage 3rd stage 4th stage 5th stage 6th stage 7th stage
Stage number
setting connector
setting
11
5. MOUNTING AND INSTALLATION
5.1 Mounting/Removal of QA6ADP
(1) Mounting of the QA6ADP
The following shows procedures for mounting the QA6ADP on the
extension base unit.
A)
Disconnect the A series extension cable
from the extension base unit.
Remove a base cover from the extension
base unit.
Set the stage number setting connector of
the extension base unit.
Set the stage number setting connector of
the QA6ADP. (The setting should be same
as that of the stage number setting
connector of the extension base unit.)
In case of the A5B, disconnect a lead of
the FG terminal (right side).
Among screws fixing a board of the
extension base unit, remove two at the
left. (Screws A and B shown in the figure.)
B)
Utilize a mounting bracket fixing screw to
mount the adapter module mounting
bracket of the QA6ADP into a screw hole
(B) at the bottom left of the board.
Board fixing screw
Mount a board fixing screw of the QA6ADP
to a screw hole (A) at top left of the board.
Connect an extension base unit mounting
connector of the QA6ADP to the IN side of
an extension connector of the extension
base unit.
Tighten the adapter module mounting
screws of the QA6ADP at two parts
(top and bottom), placing a mounting guide.
Mount an upper mounting screw to a
board fixing screw (at top left) of the
extension base unit.
Mount a lower mounting screw to the
adapter module mounting bracket.
In case of the A5B, connect the
disconnected lead of the FG terminal
(right side).
Mounting
guide
Extension
base unit IN
side connector
Adapter module
mounting
bracket
Adapter module
mounting
screw
Mounting bracket
fixing screw
Adapter module
mounting screw
Connect the Q series extension cable to the
QA6ADP and the upper/lower base unit.
Completed
12
QA6ADP
(2) Removal of the QA6ADP
The following shows procedures for removing the QA6ADP from
the extension base unit.
Disconnect an extension cable form the
QA6ADP.
Board fixing screw
Remove the adapter module mounting
screws of the QA6ADP at two parts (top
and bottom).
Remove the QA6ADP main body from the
extension base unit.
Remove a board fixing screw and an
adapter module mounting bracket of the
QA6ADP.
Mounting
guide
Extension
base unit IN
side connector
Adapter module
mounting bracket
Adapter module
mounting
screw
Mount a screw fixing the board of the
extension base unit at two parts on the left.
Mounting bracket fixing screw
Place a base cover over the extension
base unit.
Adapter module
mounting screw
Completed
13
QA6ADP
5.2 Connection/Disconnection of Extension Cable
(1) Precautions for handling an extension cable
• Do not step on an extension cable.
• When laying an extension cable, the minimum bend radius of
the cable should be 55 mm (2.17 inch) or more. If it is less than
55 mm (2.17 inch), malfunction may occur due to characteristic
deterioration, wire break etc.
• When connecting or disconnecting an extension cable, do not
hold ferrite cores mounted at both ends of the cable. In case of
connecting/disconnecting a cable, hold the connector part of the
cable.
Extension
base unit
Connector
Ferrite core
Extension
cable
Holding a ferrite core may cause cable break inside the connector.
Also, if the ferrite core is shifted, the characteristic will change.
When handling the cable, take care not to change position of the
ferrite core.
(2) Connection of extension cable
The following shows extension cables connectable to the QA6ADP.
Model
QC05B
QC06B
QC12B
QC30B
QC50B
QC100B
Remarks
0.45m cable
0.6m cable
1.2m cable
3m cable
5m cable
10m cable
14
POINT
When connecting the base unit of the previous stage and the QA6ADP with an extension
cable, be sure to connect the OUT side connector of the base unit of the previous stage and
the IN side connector of the QA6ADP.
If an extension cable is connected in the wrong way (ININ, OUTOUT or INOUT), the
system will not operate normally.
• To connect an extension cable to the QA6ADP, remove a sticker
on the IN side connector.
Base cover
IN side
Extension
base unit
QA6ADP
Sticker
• To connect an extension cable to the OUT side connector of the
QA6ADP, remove the portion (lid) under the characters "OUT"
by tools such as a flathead screwdriver (5.5×75, 6×100).
Extension base unit
Base cover
OUT side
QA6ADP
Flathead screwdriver
15
Cutting one
thin-walled part
• Hold the connector part of an extension cable when connecting
the extension cable to the QA6ADP.
Extension base unit
QA6ADP
Connector
Extension cable
• Make sure to tighten fixing screws of the extension cable
connector after connecting the extension cable.
(Tightening torque: 0.20 N•m)
Extension base unit
Flathead screwdriver
QA6ADP
Fixing
screw
(3) Disconnection of extension cable
When disconnecting an extension cable, hold and pull the
connector part of the extension cable after making sure that fixing
screws have been completely removed.
16
6. PRECAUTION FOR USING QA6ADP
6.1 Current Consumption of QA6ADP
Since 5VDC is supplied to the QA6ADP from the power supply module
of the main base unit, take the current consumption of the QA6ADP into
consideration when selecting the power supply module for the main
base unit.
Current consumption of CPU Current consumption Current consumption Current consumption
+
+
and I/O of main base unit
of I/O of Q5B
of I/O of A5B + of QA6ADP n
n: Quantity of QA6ADP in system
*1 The quantity of the QA6ADP includes the QA6ADP when the A6B is used.
The following shows the concept of the current consumption of the
power supply module mounted on the main base unit.
Main base unit
Power
supply
I0
Extension base unit (QA6B)
Power
supply
First extension stage
I1
IA
Extension base unit (A5B)
Second extension stage
I2
IA
Extension base unit (A5B)
Third extension stage
I3
IA
Extension base unit (A6B)
Power
supply
Fourth extension stage
I4
Symbol
I
I0
I1 to I4
IA
Description
Rated current of power supply module on the main base unit
Current consumption of CPU and I/O modules mounted on the main base unit
Current consumption of I/O mounted on the extension base unit in first to fourth
stages
Current consumption of the QA6ADP
17
*1
In case of the above system, use the QA6ADP when the current
consumption of the power supply module mounted on the main base
unit meets the following formula.
[Calculating formula]
I > I0 + I2 + I3 + IA
3
6.2 Voltage Drop of Extension Cable
Since 5VDC is supplied to the QA6ADP from the power supply module
mounted on the main base unit, the voltage drop will be caused in the
extension cable.
If the specified voltage (4.75VDC or more) is not supplied to the IN side
connector of the QA6ADP+A5B/A6B, wrong input/output may occur.
When using the QA6ADP, check that the IN side connector of the
QA6ADP+A5B/A6B has 4.75VDC or more.
The following shows an example regarding how to calculate the voltage
drop.
Main base unit
Power
supply
module
V1
V2
R2
I2+IA 2
Power
supply
module
IA
I1
R3
IA
Symbol
V
V1
Vn
R1
Rn
I1 to I3
IA
IA
First extension
stage
Extension base unit (A5 B)
Second extension
stage
I2
V3
Model
Extension base unit (QA6 B)
R1
I2+IA 2
QC05B
QC06B
QC12B
QC30B
QC50B
QC100B
Conductor
resistance value
0.044
0.051
0.082
0.172
0.273
0.530
Extension base unit (A6 B)
Power
supply
module
Third extension
I3
stage
Description
Sum of voltage drop
Voltage drop due to an extension cable between the main base unit and the QA6B
Voltage drop due to an extension cable between the extension base unit (n-1th
extension stage) and the extension base unit (nth extension stage)
Resistance value of a cable between the main base unit and the extension base unit
QA6B
Resistance value of an extension cable between the extension base unit (n-1th
extension stage) and the extension base unit (nth extension stage)
Current consumption (5VDC) at the first to the third extension base units*1
Current consumption of the QA6ADP
18
*1
Current consumption at each extension base unit is as follows:
First extension base unit: None
Second extension base unit: IA+I2
Third extension base unit: IA
Since the first extension base unit and the third extension base unit are
supplied from the power supply module on each extension base unit, the
values are not included above.
Since the current consumptions I1 to I3 vary depending on modules to be
mounted, refer to the manual for the module to be mounted.
[Calculating formula]
V = V1 + V2 + V3 = R1 (I2 + IA 2) + R2 (I2 + IA 2) + R3 IA
The minimum value of the 5VDC output voltage of the power supply module
mounted on the main base unit is set to 4.90VDC. Therefore, the voltage of
the IN side connector of the QA6ADP+A5B/A6B in the final stage is
4.75VDC or more only when the sum (V) of voltage drop is 0.15V or less.
19
7. COMPATIBLE MODELS LIST
This chapter describes external dimensions of the QA6ADP.
A series extension base unit
that you have already had
QA6ADP QA conversion
adapter module
2 6-M4 screw
(for mounting module)
4-f 6mounting hole
(M5 mounting screw)
Handle
I/O
I/O
I/O
I/O
I/O
200 (7.87)
130 (5.11)
POWER
9 (0.35)
74 (2.91)
73.5 (2.89)
Power supply module, Extension cable
250 (9.84)
Power supply module
Extension cable
121 (4.76)
172 (6.77)
Unit: mm (inch)
20
WARRANTY
Mitsubishi will not be held liable for damage caused by factors found not to be the cause of
Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage,
secondary damage, accident compensation caused by special factors unpredictable by
Mitsubishi; damages to products other than Mitsubishi products; and to other duties.
Country/Region Sales office/Tel
Country/Region Sales office/Tel
USA
Mitsubishi Electric Automation lnc.
500 Corporate Woods Parkway, Vernon
Hills, IL 60061, USA
Tel : +1-847-478-2100
South Africa
CBI-Electric.
Private Bag 2016, ZA-1600 Isando,
South Africa
Tel : +27-11-977-0770
Brazil
MELCO-TEC Representacao Comercial
e Assessoria Tecnica Ltda.
Av. Paulista, 1439, cj74, Bela Vista,
Sao Paulo CEP: 01311-200-SP Brazil
Tel : +55-11-3146-2200
China
Mitsubishi Electric Automation (China) Ltd.
No.1386 Hongqiao Road, Mitsubishi
Electric Automation Center, Changning
District, Shanghai, China
Tel : +86-21-2322-3030
Germany
Mitsubishi Electric Europe B.V. German
Branch
Gothaer Strasse 8, D-40880 Ratingen,
Germany
Tel : +49-2102-486-0
Taiwan
Setsuyo Enterprise Co., Ltd.
6F., No.105, Wugong 3rd Road, Wugu
District, New Taipei City 24889, Taiwan,
R.O.C.
Tel : +886-2-2299-2499
UK
Mitsubishi Electric Europe B.V. UK Branch
Travellers Lane, Hatfield, Hertfordshire,
AL10 8XB, UK.
Tel : +44-1707-27-6100
Korea
Italy
Mitsubishi Electric Europe B.V. Italian
Branch
Viale Colleoni 7-20864 Agrate Brianza
(Milano), Italy
Tel : +39-039-60531
Mitsubishi Electric Automation
Korea Co., Ltd.
3F, 1480-6, Gayang-Dong, Gangseo-Gu,
Seoul, 157-200, Korea
Tel : +82-2-3660-9530
Singapore
Mitsubishi Electric Europe B.V. Spanish
Branch
Carretera de Rubi 76-80.AC.420, E-08190
Sant Cugat del Valles (Barcelona), Spain
Tel : +34-93-565-3131
Mitsubishi Electric Asia Pte, Ltd. Industrial
Division
307, Alexandra Road, Mitsubishi Electric
Building, Singapore, 159943
Tel : +65-6470-2308
Thailand
Mitsubishi Electric Automation (Thailand)
Co., Ltd.
Bang-Chan Industrial Estate No.111
Soi Serithai 54,
T.Kannayao, A.Kannayao, Bangkok
10230 Thailand
Tel : +66-2906-3238
Indonesia
P. T. Autoteknindo Sumber Makmur
Muara Karang Selatan, Block A / Utara
No.1 Kav. No. 11,
Kawasan Industri Pergudangan,
Jakarta-Utara 14440, P.O, Box 5045,
Indonesia
Tel : +62-21-663-0833
India
Mitsubishi Electric India Pvt. Ltd.
2nd Floor, Tower A & B, Cyber Greens,
DLF Cyber City, DLF Phase-III,
Gurgaon-122002 Haryana, India
Tel : +91-124-463-0300
Australia
Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road PO BOX11,
Rydalmere, N.S.W 2116, Australia
Tel : +61-2-9684-7777
Spain
France
Mitsubishi Electric Europe B.V. French
Branch
25, Boulevard des Bouvets, F-92741
Nanterre Cedex, France
Tel : +33-1-5568-5568
Czech Republic Mitsubishi Electric Europe B.V.-o.s.Czech
office
Avenir Business Park, Radicka 751/113e,
158 00 Praha5, Czech Republic
Tel : +420-251-551-470
Poland
Mitsubishi Electric Europe B.V. Polish
Branch
ul. Krakowska 50, 32-083 Balice, Poland
Tel : +48-12-630-47-00
Russia
Mitsubishi Electric Europe B.V. Russian
Branch St.Petersburg office
Piskarevsky pr. 2, bld 2, lit "Sch", BC
"Benua", office 720; 195027,
St. Petersburg, Russia
Tel : +7-812-633-3497
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry
of Economy, Trade and Industry for service transaction permission.