American Dynamics RCTT16BE Operator`s manual

Add to my manuals
15 Pages

advertisement

American Dynamics RCTT16BE Operator`s manual | Manualzz

View Manager 16 Plus

Enhanced T

OUCH

T

RACKER

®

Installation Guide

About this Guide

These installation instructions explain how to setup the VM16+ Enhanced T OUCH T RACKER . Other related documents are:

• System Operator's Manual, 8000-2653-01

• Quick Reference Guide, 8000-2654-01

B

A

Peel

Info

Men u

Iris

Outp

Off ut

On

Clea r

Clos e

Ope n

7

0

4

1

2

8

3

5 Flip

9

6

Prev ious

Next

View

Patte rn

Repe at

Patte rn

Seq

D

C

If you need assistance...

Contact your Sensormatic Representative.

RCTT16BE

Contents

About this Guide................................................................... 1

Changes from Prior Version ......................................... 1

T OUCH T RACKER Installation................................................. 2

Installation Diagrams............................................................ 3

Installation Notes .......................................................... 3

Enhanced T OUCH T RACKER with Multiplexer

(DB25 connection)........................................................ 4

Enhanced T OUCH T RACKER with Multiplexer

(RJ11 connection) ........................................................ 5

Enhanced T OUCH T RACKER with Quad Splitter

(RJ45 connection) ........................................................ 6

Enhanced T

OUCH

T

RACKER

with RVQX7X Quad

Splitter........................................................................... 7

Enhanced T OUCH T RACKER with Intellex 1.x ................ 8

Enhanced Touch Tracker with Intellex 2.0 ................... 9

Enhanced Touch Tracker with Intellex 2.1 ................. 10

Enhanced T OUCH T RACKER and Duplex Remote Panel

(RVDRP)..................................................................... 11

Enhanced T OUCH T RACKER with Domes Only

(No External Unit) ....................................................... 12

Configuring the External Device......................................... 13

Setting Primary and Secondary Unit.................................. 13

Additional Touch Tracker Tasks......................................... 14

Displaying System Information ................................... 14

Performing the SensorNet Ping Test.......................... 14

Resetting a Dome....................................................... 14

Adjusting V-Phase ...................................................... 14

Specifications ..................................................................... 15

SensorNet................................................................... 15

Enhanced Touch Tracker ........................................... 15

Declarations ....................................................................... 15

Regulatory Compliance .............................................. 15

© 2005 Sensormatic Electronics Corp.

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER

INSTALLATION GUIDE

1 of 15

Changes from Prior Version

Significant changes are noted with revision bars in margins.

• Updated bill of materials for RVEIMKITE.

• Moved location of installation diagrams in document.

• Updated wiring diagrams for Intellex units and

Duplex Remote Panel.

• Updated Regulatory Compliance statement.

8000-2672-01, REV. D1

T

OUCH

T

RACKER

Installation

RVEIMKITE T

OUCH

T

RACKER

Installation Kit

Part Number

6003-0047-01

5899-0004-102

2880-0083-01

2816-7634-44

2109-0254-04

2141-0002

6002-0024-01

0649-0006-02

0649-0006-04

2450-0008-01

3600-0032-01

0300-1000-01

6003-0107-01

2125-0007-02

2130-0021-01

2103-0092-01

8000-2672-01

0649-0006-06

8000-2653-01

8000-2654-01

8000-1370-02

6003-0108-01

RPNR00

Description

CBL/A, MDR, 14',8 C,CROSS-P'D

SCR, TCUT, M2.9X9.5, PHP, ST,Z,T1

ANCH, PL, W/O SCR, 3/4L,#4-#6-#8

SCR, TYP AB, PHP, ST, Z, 8X1

CON, P, EUR,.2C,28-12G,1X5P

LUG, SPADE, INSUL, 22-168

CBL, 3C, 18G, CM

BAG PLASTIC 4 X 6 1/2 4MIL

BAG PLASTIC 8 X 10 4 MIL THK

LBL, BLNK, PAP, THERM, 89X76M, RL

PRINTING SPEC, LABEL

INTERCONNECT BOX, TOUCH TRACK

CBL/A, QUAD, SW, INTFCE

HOOD, D, 9P, EMI/RFI, 1/4 D CBL

CON, D,P, HSG, 9P, SSI

CONT, P, D, 26-22,AU

INSTL INSTRS, TT ENHANCED

BAG, PLASTIC 12-1/2 X 14X4MIL

SYS OPERATOR'S MANUAL, VM16

SYS QUICK GUIDE, VM16

TTRACKER STRAIN RELIEF INSTR

CBL/A, VM16+/TNG, MUX/INTFCE

CBL/A, RS-232, 10', DB9F-DB9M

For Quad Splitter (RVQX7X) with DB9 Connector

1

1

1

1

1

3

1

1

1

1

1

1

1

1

1

1

0

Quantity

1

1

2

2

1

3

16.5

These additional parts are required.

PN Description

2103-0092-02 DB9 Female contact pins

2103-0092-01 DB9 Male contact pins

2130-0021-01 DB9 Male Connector

2130-0022-01 DB9 Female Connector

Quantity

2

5

5

1

1

!

WARNING: RISK OF ELECTRIC

SHOCK! Disconnect AC Power to the switch.

!

CAUTION-Electrostatic Sensitive

Device: Follow proper handling procedures to prevent component failure.

Note: Prior to installing the Enhanced T OUCH

T RACKERS , identify the type of external unit that will connect to the Enhanced T OUCH T RACKER , if applicable. Build any cables that are required.

Refer to the Installation Diagrams starting on page 3 for specific instructions.

1. Terminate the External Interconnect Module

(EIM) at the end of the SensorNet network. If more than one Enhanced T OUCH T RACKER controller will be installed, one T OUCH

T RACKER 's EIM will be terminated; the other EIM will be unterminated. Refer to the appropriate wiring diagram for your configuration.

2. Mount each EIM on a wall or other surface within 3m (10 feet) of the Touch Tracker controller.

3. Connect the power transformer and SensorNet cable to J3 on each EIM. If two Touch Trackers will be installed, connect the SensorNet cable from the first EIM to the second EIM.

4. Depending on the external unit that will be attached to your system, connect the appropriate cable to the DB9 connector on the

EIM. Refer to the appropriate wiring diagram for additional details.

5. Connect the data cable from J1 on the Primary

T OUCH T RACKER 's EIM to the remote port on the external unit. Refer to the appropriate wiring diagram for additional details.

6. Connect the modular cable from J2 on each

EIM to the T OUCH T RACKER controller.

7. Connect the SensorNet cable from the dome to the first EIM. Refer to the appropriate wiring diagram for additional details.

8. Plug in the power transformer into a grounded,

3-wire receptacle.

Note: If the keypad and backlighting do not illuminate when power is applied, unplug each power transformer and repeat steps 3 through 8.

Depending on system configuration, it may take up to 2 minutes for the Enhanced T OUCH T RACKER to come completely online.

Continue with Configuring the External Device.

8000-2672-01, REV. D1 RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER

INSTALLATION GUIDE

2 of 15

Installation Diagrams

The following pages illustrate the installation of the

VM16+ Enhanced Touch Tracker in the following configurations:

Enhanced Touch Tracker with Multiplexer

(DB25 connection)................................................4

Enhanced Touch Tracker with Multiplexer

(RJ11 connection) ................................................5

Enhanced Touch Tracker with Quad Splitter

(RJ45 connection) ................................................6

Enhanced Touch Tracker with RVQX7X Quad

Splitter ...................................................................7

Enhanced T OUCH T RACKER with Intellex 1.x ...... 8

Enhanced Touch Tracker with Intellex 2.0.........9

Enhanced Touch Tracker with Intellex 2.1.......10

Enhanced Touch Tracker and Duplex Remote

Panel (RVDRP) ...................................................11

Enhanced T OUCH T RACKER with Domes Only (No

External Unit) ......................................................12

Refer to the appropriate diagram when connecting the Enhanced Touch Tracker.

Installation Notes

• Depending on configuration, two Enhanced

T OUCH T RACKERS may be installed. Terminate

E1 on the EIM that is on the end point of the

SensorNet Network.

• The maximum combined SensorNet cable length is 1000 m (one km or 3000').

• J-Box and dome wiring information is included for information purposes only. Refer to the

J-Box or dome installation instructions for complete wiring information.

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER

INSTALLATION GUIDE

3 of 15

8000-2672-01, REV. D1

Enhanced T

OUCH

T

RACKER

with Multiplexer (DB25 connection)

COLOR

Orange

Yellow

Orange

Yellow

PIN FUNCTION

1

2

Host A

Host B

4

Auxiliary A

Auxiliary B

COLOR

Orange

White

Red

Black

Yellow

PIN

1

2

3

4

5

FUNCTION

SensorNet A

28 Vac

Ground

28 Vac

SensorNet B

Your system supports up to

2 controllers. Terminate E1 on the EIM that is on the end point of the SensorNet

Network.

Connect to

Remote

DB25F

COLOR

RED

BLACK

DB9M

2 Tx

5 Ground

DB25M

25 Rx

14 Ground

The maximum combined

SensorNet cable length is

1000 m (3000').

8000-2672-01, REV. D1 RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER

INSTALLATION GUIDE

4 of 15

Enhanced T

OUCH

T

RACKER

with Multiplexer (RJ11 connection)

COLOR

Orange

Yellow

Orange

Yellow

PIN FUNCTION

1

2

4

Host A

Host B

Auxiliary A

Auxiliary B

COLOR

Orange

White

Red

Black

Yellow

PIN

3

4

1

2

5

FUNCTION

SensorNet A

28 Vac

Ground

28 Vac

SensorNet B

To Dome

Refer to instructions included with device.

Your system supports up to

2 controllers. Terminate E1 on the EIM that is on the end point of the SensorNet

Network.

COLOR

RED

BLACK

PIN

2

5

FUNCTION

TRANSMIT

GROUND

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER

INSTALLATION GUIDE

5 of 15

The maximum combined

SensorNet cable length is

1000 m (3000').

8000-2672-01, REV. D1

Enhanced T

OUCH

T

RACKER

with Quad Splitter (RJ45 connection)

COLOR PIN

Orange 1

Yellow

Orange

2

FUNCTION

Host A

Host B

Auxiliary A

Yellow 4 Auxiliary B

COLOR

Orange

White

Red

Black

Yellow

PIN

3

4

1

2

5

FUNCTION

SensorNet A

28 Vac

Ground

28 Vac

SensorNet B

To Dome

Refer to instructions included with device.

The maximum combined

SensorNet cable length is

1000 m (3000').

TERMINATED

Only one Touch Tracker may be installed with the dual page Quad Splitter.

This EIM must be terminated.

COLOR

RED

ORANGE

PIN

5

FUNCTION

TRANSMIT

GROUND

COLOR

GREEN

ORANGE

PIN

2

5

FUNCTION

TRANSMIT

GROUND

COLOR

GREEN

RED

ORANGE

PIN

5

2

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER

INSTALLATION GUIDE

6 of 15

8000-2672-01, REV. D1

Enhanced T

OUCH

T

RACKER

with RVQX7X Quad Splitter

COLOR PIN

Orange 1

Yellow

Orange

Yellow

2

4

FUNCTION

Host A

Host B

Auxiliary A

Auxiliary B

COLOR

Orange

White

Red

Black

Yellow

PIN

1

2

3

4

5

FUNCTION

SensorNet A

28 Vac

Ground

28 Vac

SensorNet B

To Dome

Refer to instructions included with device.

The maximum combined

SensorNet cable length is

1000 m (3000').

TERMINATED

Only one Touch Tracker may be installed with the Quad

Splitter. This EIM must be terminated.

PART

DB9 Hood

DB9 Female contact pins 5

DB9 Male contact pins

DB9 Male Connector

DB9 Female Connector

QTY

2

5

1

1

PN

2125-0007-02

2103-0092-02

2103-0092-01

2130-0021-01

2130-0022-01

EIM DB9M

2 Tx

5 Ground

2 Rx

1 Ground

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER

INSTALLATION GUIDE

7 of 15

8000-2672-01, REV. D1

Enhanced T

OUCH

T

RACKER

with Intellex 1.x

J-Box P8 J-Box P1-P6

Color Pin Function Color Pin Function

J-Box #1

White 2 28

Red 3 Ground P4

Black 4 28

P5

Yellow 5 SensorNet

P6

P8

P1

P2

P3

To Dome

Refer to instructions included with device.

3 2 1

TERMINATED

Only one Touch Tracker may be installed with E1

Intellex. This EIM must be terminated.

DB9M

24 Vac A

Ground

24 Vac B

EIM #1

5 4 3 2 1

ASSY

0301-0340-01 REV-

RJ45

Straight-Thru Cable Wiring

EIM DB9F

2 Tx

3 Rx

5 Ground

COM 1

2 Rx

3 Tx

5 Ground

RJ45

Intellex 1.x

(with DB9 Connector)

Straight-Thru Cable

PN: RPNR00

Primary

Touch Tracker The maximum combined

SensorNet cable length is 1000m (3000’).

DB9 Connector

DB9F

8000-2672-01, REV. D1 RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER

INSTALLATION GUIDE

8 of 15

Enhanced Touch Tracker with Intellex 2.0

J-B ox #1

J-Box P8 J-Box P1-P6

Color Pin Function Color Pin Function

White 2 28

Red 3 Ground

Black 4 28

P4

P5

P6

P8

P1

P2

P3

To Dome

Refer to instructions included with device.

3 2 1

Terminated

Only one Touch Tracker may be installed with

Intellex. This EIM must be terminated.

E1

DB9M

24 Vac A

Ground

24 Vac B

EIM #1

5 4 3 2 1

ASSY

0301-0340-01 REV-

RJ45

Straight-Thru Cable Wiring

EIM DB9F

2 Tx

3 Rx

5 Ground

COM 2

2 Rx

3 Tx

5 Ground

Intellex 2.0

(with DB9 Connector)

RJ45

Primary

Touch Tracker

The maximum combined

SensorNet cable length is 1000m (3000’).

Straight-Thru Cable

PN: RPNR00

DB9F

COM 1 COM 2

DB9 Connector

8000-2672-01, REV. D1 RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER

INSTALLATION GUIDE

9 of 15

Enhanced Touch Tracker with Intellex 2.1

J-Box P8

Color Pin Function

J-Box P1-P6

Color Pin Function

J-Box #1

White 2 28

Red 3 Ground

Black 4 28 P4

Yellow 5 SensorNet P5

P6

P8

P1

P2

P3

To Dome

Refer to instructions included with device.

Your system supports up to

2 controllers. Terminate E1 on the EIM that is on the end point of the SensorNet

Network.

DB9M

Straight-Thru Cable Wiring

EIM DB9F

2 Tx

3 Rx

5 Ground

COM 2

2 Rx

3 Tx

5 Ground

RJ45

RJ45

Primary

Touch Tracker

The maximum combined

SensorNet cable length is 1000m (3000ft).

Secondary

Touch Tracker

Intellex 2.1

(with DB9 Connector)

Straight-Thru Cable

PN: RPNR00

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER

INSTALLATION GUIDE

COM 1 DB9 Connector

10 of 15

DB9F

Call monitor feature board is used if Secondary Touch

Tracker is installed.

8000-2672-01, REV. D1

Enhanced T

OUCH

T

RACKER

and Duplex Remote Panel (RVDRP)

To Dome

Refer to instructions included with device.

To Your Remote

Mux Location

1 2 3 4 5

1 2 3 4 5

P4

P5

1 2 3 4 5

P6

DOME 456

Jw2 T

3 2 1

HOST

Jw3

3 2 1

T

P8

HOST AUX

1 2 3 4 5

P1

1 2 3 4 5

P2

P3

1 2 3 4 5

T

DOME 123

Jw1

3 2 1

T

3 2 1

AUX

JW4

Pin 4 Pin 1

Pin 19 in out

RV2216 BACK VIEW

Pin 1 s-vhs s-vhs out in vcr in vcr out call main cam 1 in out cam 16

REMOTE DUPLEX MUX (RVDRP)

IN OUT Back View

NOTE: Both ends of this cable connect to the ports labeled “data in”.

Pin 1 Pin 4

J3

J1

0300-1000-01

EIM #1

RJ45

DB9

J2

T=Terminated

U=Unterminated

J1

J3

0300-1000-01

EIM #2

RJ45

DB9

J2

2

5

6003-0047-01

SECONDARY

TOUCH TRACKER

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER

INSTALLATION GUIDE

6003-0047-01

EIM DB9F Wiring

Color Pin

Red 2

Black 5

Note: Green wire is not used.

NOTE: The Touch Tracker is always connected to the last output of the remote multiplexers.

PRIMARY

TOUCH TRACKER

8000-2672-01, REV. D1

11 of 15

Enhanced T

OUCH

T

RACKER

with Domes Only (No External Unit)

Use this wiring diagram when domes will be connected to dedicated monitors.

COLOR

Orange

Yellow

Black

Red

White

PIN

1

2

3

4

5

FUNCTION

SensorNet A

SensorNet B

24 Vac A

Ground

24 Vac B

COLOR PIN FUNCTION

Orange P1 Lead 5 SensorNet A

Yellow P1 Lead 6 SensorNet B

Black P7 Lead 1 24 Vac A

Red P7 Lead 2 Ground

White P7 Lead 3 24 Vac B

The maximum combined

SensorNet cable length is

1000 m (3000').

Only one Touch Tracker may be installed with standalone configurations. This EIM must be terminated.

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER

INSTALLATION GUIDE

12 of 15

8000-2672-01, REV. D1

Configuring the External

Device

Use this procedure to select the external device that connects to the Enhanced T OUCH T RACKER .

1. From the primary Enhanced T OUCH T RACKER , press Menu to configure the software for the external system. The menu appears on the

LCD.

2. Use the Tracker Ball to scroll through the menu until Config Devices appears on the LCD screen. Press zoom or focus to select Config

Devices.

3. Press Next to scroll through the available devices. Refer to the following chart to determine which device to select.

Device Setting Use with...

Device 16-camera Multiplexer and

=Mux

Device 9-camera Multiplexer

9

Device 4-camera Multiplexer, dual page

4

(RVQX7X)

Device Quad Splitter with DB9F-RJ45

=Quad

Device Domes connected to dedicated

=None

Device

=PC

For Service use only

4. When the correct configuration appears on the

LCD, press Menu.

Continue with Setting Primary and Secondary

Unit.

Setting Primary and

Secondary Unit

NOTE: Quad Splitter, Intellex 1.x and 2.0, and stand-alone installations support only one Touch

Tracker.

If you have two Enhanced T OUCH T RACKERS installed, one must be designated as Primary; the other must be designated as Secondary. If you have only one Enhanced T OUCH T RACKER installed, it must be designated as Primary.

1. Press Menu.

2. Using the Tracker Ball, scroll the menu choices until Tog Primary/2nd appears on the LCD.

3. Press zoom or focus to select Tog

Primary/2nd. Zoom selects the top line; focus selects the bottom line.

4. Press Next to toggle between setting the

Enhanced T OUCH T RACKER as primary or secondary. When the appropriate choice appears on the LCD, press Menu. The

Enhanced T OUCH T RACKER will reset.

Repeat this procedure for each Enhanced T OUCH

T RACKER .

8000-2672-01, REV. D1 RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER

INSTALLATION GUIDE

13 of 15

Additional Touch Tracker

Tasks

The following maintenance functions can be performed using the Touch Tracker. When using the menus, pressing Zoom selects the first line of the LCD; pressing Focus selects the second line of the LCD.

Resetting a Dome

This feature allows you to reinitialize a SpeedDome or SpeedDome Ultra family camera dome.

1. Use the number buttons to the select the dome to reset then press (Camera button).

Displaying System Information

This procedure displays system information about the

Enhanced T

OUCH

T

RACKER

being used.

1. Use the number buttons to the select the dome to reset, and then press (Camera button).

3. Using the Tracker Ball, scroll through the choices until System Info appears on the LCD.

4. Press System Info. information.

The LCD displays the following information:

− Unit Type: Primary or Secondary

3. Using the Tracker Ball, scroll through the choices until Reset Dome appears on the

LCD.

4. Press Reset Dome.

The Enhanced T OUCH T RACKER sends a request to the selected dome to reboot. After a brief delay, the

T OUCH T RACKER resumes camera control mode.

Adjusting V-Phase

Use this procedure to adjust the vertical phase for cameras installed with your system.

− Calibration information (display should read all

0)

− Product Code Flash Version

− Product Code EEPROM Version

2. Using the Tracker Ball, scroll through the choices until Adjust V-phase appears on the LCD.

3. Press Adjust Vphase.

Performing the SensorNet Ping

Test

This procedure tests communications between the

Enhanced T OUCH T RACKER and domes installed at your facility.

1. Use the number buttons to the select the dome to ping then press (Camera button).

3. Using the Tracker Ball, scroll through the choices until Ping Dome/TTR appears on the LCD.

4. Press Ping

Dome/TTR. primary or secondary Touch Tracker.

Note: Off-line domes or fixed cameras will generate a warning beep and not permit the use of the Ping test.

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER

INSTALLATION GUIDE

14 of 15 through the oscilloscope or Fluke scope.

5. When you are satisfied with the setting, press

Menu to exit.

Note: Off-line domes or fixed cameras will generate a warning beep and not permit the use of the V-phase utility.

8000-2672-01, REV. D1

Specifications

SensorNet

Bit Rate:............................. 230.4Kbps

Physical Layer: ................. Non-shielded twisted pair

Link Layer Protocol: .......... SDLC

Application Protocol: ......... Proprietary

Network Nodes: ................ Touch Tracker,

SensorNet Domes

Enhanced Touch Tracker

Operator Inputs: ............... 31-key keypad,

4 micro-switches,

1 Tracker Ball

Operator Outputs: ............. LCD screen

(2-line x 16 character)

Control Input/Output: ........ SensorNet (Domes,

Touch Tracker), RS-232

(multiplexer or quad splitter)

Electrical

Power Source: .................. 16–30Vac at 50/60Hz

Power Consumption: ........ 1400mA, 2A max.

Mechanical, Touch Tracker

Height: .............................. 13cm (5in.)

Width: ............................... 19cm (7.5in.)

Depth: ............................... 26cm (10in.)

Weight: ............................. 1kg (2.2lbs)

Environmental

Operating Temperature: ... 0°–50°C

(32°–122°F)

Relative Humidity: ............ 0%–95% non-condensing

Storage Temperature: ...... -20°–64°C

(-4°–149°F)

Product Compatibility

SensorNet Interface: ........ SpeedDome family

RS-232 Serial Port: .......... Monochrome Mux,

Color Mux,

Monochrome Quad,

Color Quad, Intellex,

Standard PC

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER

INSTALLATION GUIDE

15 of 15

Declarations

Regulatory Compliance

Emissions:..........................FCC Part 15 Class A;

EN 55022 Class B.

Immunity: ...........................EN 50130-4

Safety Complies

UL1950;

CSA - C22.2 No 950-M89;

EN 60950.

FCC COMPLIANCE: This equipment has been tested and found to comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation.

EQUIPMENT MODIFICATION CAUTION: Equipment changes or modifications not expressly approved by Sensormatic Electronics

Corporation, the party responsible for FCC compliance, could void the user's authority to operate the equipment and could create a hazardous condition.

Other Declarations

INSTALLATION: This installation should be made by a qualified service person and should conform to all local codes. In North

America, this device is intended to be supplied from a nominal 24Vac

Class 2 power supply. In the EU, this device is intended to be powered from a Certified (for the country of use), CE marked, source of SELV, not exceeding 240 VA available.

INSTALLATION: Diese Installation sollte von einem qualifizierten

Wartungstechniker vorgenommen werden und allen örtlichen

Vorschriften entsprechen. In Nordamerika ist dieses Gerät für die

Stromversorgung durch ein Netzgerät der Klasse 2 mit einer

Nennleistung von 24 V Wechselstrom vorgesehen. In der EG ist dieses

Gerät für die Stromversorgung durch eine (für das Verwendungsland) zertifizierte, mit der CE Marke versehene Schutzkleinspannungsquelle

(SELV) vorgesehen, die 240 V Wechselstrom nicht überschreiten darf.

WARRANTY DISCLAIMER: Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Further,

Sensormatic Electronics Corporation reserves the right to revise this publication and make changes from time to time in the content hereof without obligation of Sensormatic Electronics Corporation to notify any person of such revision or changes.

LIMITED RIGHTS NOTICE: For units of the Department of

Defense, all documentation and manuals were developed at private expense and no part of it was developed using Government Funds.

The restrictions governing the use and disclosure of technical data marked with this legend are set forth in the definition of “limited rights” in paragraph (a) (15) of the clause of DFARS 252.227.7013.

Unpublished - rights reserved under the Copyright Laws of the United

States.

TRADEMARK NOTICE: T OUCH T RACKER , Sensormatic, and the

Sensormatic logo are trademarks or registered trademarks of

Sensormatic Electronics Corporation. Other product names mentioned herein may be trademarks or registered trademarks of Sensormatic or other companies.

No part of this guide may be reproduced in any form without written permission from Sensormatic Electronics Corporation.

RLJ 5/05

8000-2672-01, REV. D1

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals