Installation

Instructions

R540

CENTRAL THERMOSTAT with VOLUME CONTROL

Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.

To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

Certified to comply with ANSI A112.18.1M

ASSE 1016

M 9 6 8 2 5 7

ROUGHING-IN DIMENSIONS

VERTICAL HORIZONTAL

1-3/4" to 2-1/2"

13/16"

1-3/4" to 2-1/2"

FINISHED

WALL mixed out

FINISHED

WALL hot in

6-1/2"

2" cold in

3-1/8"

2-3/16" mixed out mixed out hot in cold in

3-1/8" mixed out

13/16"

2-13/16" NOTE: ALL PORTS ARE 3/4 NPT

FEMALE. FITTING MUST BE INSTALLED

WITH VOLUME CONTROL ON TOP.

THERMOSTATIC BATH/

SHOWER INSTALLATION

USING A TWIN ELL, DIVERTER

SPOUT AND FIXED SHOWER

THERMOSTATIC SHOWER INSTALLATION

USING A DIVERTER VALVE, FIXED

SHOWER HEAD AND ADJUSTABLE HAND

HELD SHOWER

THERMOSTATIC SHOWER INSTALLATION USING A

DIVERTER VALVE, FIXED SHOWER HEAD, ADJUSTABLE

HAND HELD SHOWER, ON/OFF VALVE AND THREE

BODY SPRAYS

DIVERTER

VALVE

C/L

80"-86"

18"

SHOWER

PORT

MUST BE

PLUGGED

4"

TWIN

ELL

TOP OF TUB RIM

BOTTOM OF TUB

THERMOSTATIC VALVE INSTALLED

IN THE VERTICAL POSITION

IMPORTANT: WHEN NOT USING A

DIVERTER SPOUT A SEPARATE

DIVERTER VALVE MUST BE USED.

DIVERTER

VALVE

HOT COLD

3/4" 3/4"

TUB PORT MUST

BE PLUGGED

THERMOSTATIC VALVE INSTALLED

IN THE HORIZONTAL POSITION

ON/OFF

VALVE

HOT COLD

3/4" 3/4"

TUB PORT MUST

BE PLUGGED

THERMOSTATIC VALVE INSTALLED

IN THE HORIZONTAL POSITION

1

ROUGHING-IN THE VALVE

CAUTION

Turn off hot and cold water supplies before beginning.

HOT

INLET

Decide on desired configuration.

Prepare water supplies per ROUGHING-IN DIMENSIONS.

Install VALVE at indicated height and depth.

Connect HOT water supply to inlet marked with the RED DOT and

COLD water supply to inlet market with the BLUE DOT.

Assemble the CONNECTING PIPE to one of the MIXED OUTLETS of the VALVE.

Note: The tub port is fitted with a plug at the factory.

Important! Install any required shut off or diverter valves into the piping system.

COLD

INLET

WARNING

DO NOT SOLDER DIRECTLY TO THE VALVE BODY; THIS WILL

DAMAGE THE TEMPERATURE CONTROL ELEMENT.

Secure VALVE body to cross brace of wall structure.

PLASTER

GUARD

SCREWS

PLASTER

GUARD

2

FLUSHING THE VALVE

CAUTION

Turn off hot and cold water supplies before beginning.

Water should be flushed through the piping to prevent clogging of the Thermal Element.

Remove PLASTER GUARD (1).

Turn ADAPTER (2) on volume control clockwise until it reaches the stop.

Pull off ADAPTER (2).

Remove CLUTCH COVER SCREWS (3) and CLUTCH COVER (4).

Pull out CLUTCH DRIVE SHAFT (5).

Loosen the SCREWS (6) in the center of the GEARS (7). Remove the GEARS (7) and BACK PLATE (8).

Remove the COLD CARTRIDGE (9) using a 22mm socket wrench.

Turn on MAIN COLD WATER SUPPLY to flush line.

Reassemble COLD CARTRIDGE (9) and repeat flushing steps for

HOT side (9a).

Replace BACK PLATE (8). Assemble both GEARS (7) with the flat side facing BACK PLATE (8) and tighten SCREWS (6).

IMPORTANT:

Close both CARTRIDGES (9, 9a) by rotating GEARS (7) counterclockwise.

Replace CLUTCH DRIVE SHAFT (5) and CLUTCH COVER (4) with SCREWS (3).

Turn VOLUME CONTROL HANDLE 180 to synchronize the

HOT and COLD CARTRIDGES.

Turn on water supply and check for leaks.

8

9a

9

7a

6a

7

6

1

5

3

TEMPERATURE CALIBRATION

Check that arrow marking B points vertically upwards. If not, push the BLACK

CLAMP (1) on the SECURING RING (2) to the right, pull off KNOB MOUNT (3) and reinstall KNOB MOUNT (3) with arrow "B" pointing vertically upwards.

SET HOT LIMIT STOP

The maximum mixed water temperature is set at 109 F at the factory.

This setting can be changed if desired.

4

Remove the TEMPERATURE LIMIT STOP (4) (H shaped Black Plastic part).

Reinstall it at the desired notch as indicated in the diagram to limit the maximum mixed water temperature to 104 F or 112 F.

For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT (3) until the spout temperature is 100 F. Check that arrow marking A on the KNOB MOUNT (3) still points upward after adjusting the thermostat to 100 F. If not, pull out the RED LOCKING DEVICE (5).

Remove KNOB MOUNT (3) without turning by sliding out as indicated by the arrow.

Reinstall the KNOB MOUNT (3) so that the arrow marking A points upwards.

Reinstall RED LOCKING DEVICE (5).

104

109

112

2

5

ARROW

"B"

4

PLASTER

GUARD

SCREWS

3

2

1

CROSS

BRACE

VALVE

BODY

MIXED

OUTLET

ARROW

"A"

3

M 9 6 8 2 5 7

CENTRAL THERMOSTAT

WITH VOLUME CONTROL

MODEL NUMBER

R540

923143-0070A

GEAR BOX

BACK PLATE

954040-0070A

THERMOSTATIC

CONTROL

CARTRIDGE

953963-0070A

TEMPERATURE

HANDLE EXTENSION

952550-0070A

VALVE KIT (HOT & COLD)

953156-0070A

GEAR/CLUTCH

WHEELS

953155-0070A

DRIVE SHAFT

923142-0070A

CLUTCH COVER

918327-0070A

CLUTCH COVER SCREWS

911940-0070A

GEAR BOX

SEALING WASHER

923348-0070A

HANDLE ADAPTER

953957-0070A

TEMPERATURE

CALIBRATION

ADJUSTMENT

HOT LINE FOR HELP

For toll-free information and answers to your questions, call:

1-800 442-1902

Weekdays 8:00 a.m. to 8:00 p.m. EST

IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)

Weekdays 8:00 a.m. to 7:00 p.m. EST

P r o d u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A m e r i c a n S t a n d a r d I n c .

© A m e r i c a n S t a n d a r d I n c . 2 0 0 3

M 9 6 8 2 5 7