Installation
Instructions
R540
CENTRAL THERMOSTAT with VOLUME CONTROL
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
Certified to comply with ANSI A112.18.1M
ASSE 1016
M 9 6 8 2 5 7
ROUGHING-IN DIMENSIONS
VERTICAL HORIZONTAL
1-3/4" to 2-1/2"
13/16"
1-3/4" to 2-1/2"
FINISHED
WALL mixed out
FINISHED
WALL hot in
6-1/2"
2" cold in
3-1/8"
2-3/16" mixed out mixed out hot in cold in
3-1/8" mixed out
13/16"
2-13/16" NOTE: ALL PORTS ARE 3/4 NPT
FEMALE. FITTING MUST BE INSTALLED
WITH VOLUME CONTROL ON TOP.
THERMOSTATIC BATH/
SHOWER INSTALLATION
USING A TWIN ELL, DIVERTER
SPOUT AND FIXED SHOWER
THERMOSTATIC SHOWER INSTALLATION
USING A DIVERTER VALVE, FIXED
SHOWER HEAD AND ADJUSTABLE HAND
HELD SHOWER
THERMOSTATIC SHOWER INSTALLATION USING A
DIVERTER VALVE, FIXED SHOWER HEAD, ADJUSTABLE
HAND HELD SHOWER, ON/OFF VALVE AND THREE
BODY SPRAYS
DIVERTER
VALVE
C/L
80"-86"
18"
SHOWER
PORT
MUST BE
PLUGGED
4"
TWIN
ELL
TOP OF TUB RIM
BOTTOM OF TUB
THERMOSTATIC VALVE INSTALLED
IN THE VERTICAL POSITION
IMPORTANT: WHEN NOT USING A
DIVERTER SPOUT A SEPARATE
DIVERTER VALVE MUST BE USED.
DIVERTER
VALVE
HOT COLD
3/4" 3/4"
TUB PORT MUST
BE PLUGGED
THERMOSTATIC VALVE INSTALLED
IN THE HORIZONTAL POSITION
ON/OFF
VALVE
HOT COLD
3/4" 3/4"
TUB PORT MUST
BE PLUGGED
THERMOSTATIC VALVE INSTALLED
IN THE HORIZONTAL POSITION
1
ROUGHING-IN THE VALVE
CAUTION
Turn off hot and cold water supplies before beginning.
HOT
INLET
Decide on desired configuration.
Prepare water supplies per ROUGHING-IN DIMENSIONS.
Install VALVE at indicated height and depth.
Connect HOT water supply to inlet marked with the RED DOT and
COLD water supply to inlet market with the BLUE DOT.
Assemble the CONNECTING PIPE to one of the MIXED OUTLETS of the VALVE.
Note: The tub port is fitted with a plug at the factory.
Important! Install any required shut off or diverter valves into the piping system.
COLD
INLET
WARNING
DO NOT SOLDER DIRECTLY TO THE VALVE BODY; THIS WILL
DAMAGE THE TEMPERATURE CONTROL ELEMENT.
Secure VALVE body to cross brace of wall structure.
PLASTER
GUARD
SCREWS
PLASTER
GUARD
2
FLUSHING THE VALVE
CAUTION
Turn off hot and cold water supplies before beginning.
Water should be flushed through the piping to prevent clogging of the Thermal Element.
Remove PLASTER GUARD (1).
Turn ADAPTER (2) on volume control clockwise until it reaches the stop.
Pull off ADAPTER (2).
Remove CLUTCH COVER SCREWS (3) and CLUTCH COVER (4).
Pull out CLUTCH DRIVE SHAFT (5).
Loosen the SCREWS (6) in the center of the GEARS (7). Remove the GEARS (7) and BACK PLATE (8).
Remove the COLD CARTRIDGE (9) using a 22mm socket wrench.
Turn on MAIN COLD WATER SUPPLY to flush line.
Reassemble COLD CARTRIDGE (9) and repeat flushing steps for
HOT side (9a).
Replace BACK PLATE (8). Assemble both GEARS (7) with the flat side facing BACK PLATE (8) and tighten SCREWS (6).
IMPORTANT:
Close both CARTRIDGES (9, 9a) by rotating GEARS (7) counterclockwise.
Replace CLUTCH DRIVE SHAFT (5) and CLUTCH COVER (4) with SCREWS (3).
Turn VOLUME CONTROL HANDLE 180 to synchronize the
HOT and COLD CARTRIDGES.
Turn on water supply and check for leaks.
8
9a
9
7a
6a
7
6
1
5
3
TEMPERATURE CALIBRATION
Check that arrow marking B points vertically upwards. If not, push the BLACK
CLAMP (1) on the SECURING RING (2) to the right, pull off KNOB MOUNT (3) and reinstall KNOB MOUNT (3) with arrow "B" pointing vertically upwards.
SET HOT LIMIT STOP
The maximum mixed water temperature is set at 109 F at the factory.
This setting can be changed if desired.
4
Remove the TEMPERATURE LIMIT STOP (4) (H shaped Black Plastic part).
Reinstall it at the desired notch as indicated in the diagram to limit the maximum mixed water temperature to 104 F or 112 F.
For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT (3) until the spout temperature is 100 F. Check that arrow marking A on the KNOB MOUNT (3) still points upward after adjusting the thermostat to 100 F. If not, pull out the RED LOCKING DEVICE (5).
Remove KNOB MOUNT (3) without turning by sliding out as indicated by the arrow.
Reinstall the KNOB MOUNT (3) so that the arrow marking A points upwards.
Reinstall RED LOCKING DEVICE (5).
104
109
112
2
5
ARROW
"B"
4
PLASTER
GUARD
SCREWS
3
2
1
CROSS
BRACE
VALVE
BODY
MIXED
OUTLET
ARROW
"A"
3
M 9 6 8 2 5 7
CENTRAL THERMOSTAT
WITH VOLUME CONTROL
MODEL NUMBER
R540
923143-0070A
GEAR BOX
BACK PLATE
954040-0070A
THERMOSTATIC
CONTROL
CARTRIDGE
953963-0070A
TEMPERATURE
HANDLE EXTENSION
952550-0070A
VALVE KIT (HOT & COLD)
953156-0070A
GEAR/CLUTCH
WHEELS
953155-0070A
DRIVE SHAFT
923142-0070A
CLUTCH COVER
918327-0070A
CLUTCH COVER SCREWS
911940-0070A
GEAR BOX
SEALING WASHER
923348-0070A
HANDLE ADAPTER
953957-0070A
TEMPERATURE
CALIBRATION
ADJUSTMENT
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 8:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)