Plena Booster Amplifier

en

Installation and Operating Manual

LBB 1930, LBB 1935,

LBB 1938

Plena Booster Amplifier | Installation and Operating Manual | Important safeguards en | 3

Important safeguards

1 Read instructions - All the safety instructions for use should be read before the system is operated.

2 Retain instructions - The safety instructions and instructions for use should be retained for future reference.

3 Heed warnings - All warnings on the unit and in the operating instructions should be adhered to.

4 Follow instructions - All operating instructions and instructions for use should be followed.

5 Cleaning - Unplug system units from the mains outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.

6 Attachments - Do not use attachments not recommended by the product manufacturer as they may cause hazards.

7 Water and Moisture - Do not use this unit near water, for example near a bathtub, washbowl, kitchen sink, or laundry basket, in a wet basement, near a swimming pool, in an unprotected outdoor installation or any area which is classified as a wet location.

8 Accessories - Do not place this unit on an unstable stand, tripod, bracket or mount. This unit may fall, causing serious injury to a person and serious damage to the unit. Use only a stand, tripod, bracket or mount recommended by the manufacturer, or sold with the product. Any mounting of the unit should follow the manufacturer's instructions, and should use a mounting accessory recommended by the manufacturer. An appliance and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the appliance and cart combination to overturn.

9 Ventilation - Openings in the enclosure, if any, are provided for ventilation and to ensure reliable operation of the unit and to protect it from overheating. These openings must not be blocked or covered. The unit should not be placed in a built-in installation unless proper ventilation is provided or the manufacturer's instructions have been adhered to.

10 Power sources - Units should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply you plan to use, consult your appliance dealer or local power company. For units intended to operate from battery power, or other sources, refer to the "Installation and

User Instructions".

11 Grounding or polarisation - This unit may be equipped with a polarised alternating current line plug (a plug having one blade wider than the other). This plug will fit into the power outlet only one way. This is a safety feature. If you are unable to insert the plug fully into the outlet, try reversing the plug. If the plug still fails to fit, contact your electrician to replace your obsolete outlet.

Do not defeat the safety purpose of the polarised plug.

Alternatively, this unit may be equipped with a 3-wire grounding type plug having a third (grounding) pin.

This plug will only fit into a grounding-type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the grounding-type lug.

12 Power-Cord Protection - Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords and plugs, convenience receptacles, and the point where they exit from the appliance.

13 Overloading - Do not overload outlets and extension cords as this can result in a risk of fire or electrical shock.

14 Object and Liquid Entry - Never push objects of any kind into this unit through openings as they may touch dangerous voltage points or short-out parts that could result in a fire or electric shock. Never spill liquid of any kind on the unit.

15 Servicing - Do not attempt to service this unit yourself as opening or removing covers may expose to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.

16 Damage Requiring Service - Unplug the unit from the outlet and refer servicing to qualified service personnel under the following conditions:

• When the power-supply cord or plug is damaged.

• If liquid has been spilled, or objects have fallen into the unit.

• If the unit has been exposed to rain or water.

• If the unit does not operate normally by following the instructions for use. Adjust only those controls that are covered by the instructions for use, as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the units to their normal operation.

• If the unit has been dropped or the unit has been damaged.

• When the unit exhibits a distinct change in performance; this indicates a need for service.

17 Replacement Parts - When replacement parts are required be sure the service technician has used replacement parts specified by the manufacturer or parts which have the same characteristics as the original part.

Unauthorised substitutions may result in fire, electric shock or other hazards.

18 Safety Check - Upon completion of any service or repairs to the units, ask the service technician to perform safety checks to determine that the unit is in proper operating condition.

19 Lightning - For added protection of the units during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet and disconnect the cable system. This will prevent damage to the unit due to lightning and power-line surges.

Bosch Security Systems | 2003-09 | 3922 988 92983en

Plena Booster Amplifier | Installation and Operating Manual | About this manual

About this manual

This manual provides all the information required to install and operate the unit.

Conventions

Warning

Follow these instructions to prevent personal injury.

Caution

Follow these instructions to prevent damage to the equipment.

Note

Read these instructions for tips and other useful information.

en | 4

Safety precautions

Warning

Do not open the unit when it is connected to the mains. The unit contains non-insulated parts, which can cause electric shock.

Caution

There are no user-serviceable parts inside the unit. Service must be done by qualified personnel.

Bosch Security Systems | 2003-09 | 3922 988 92983en

Plena Booster Amplifier | Installation and Operating Manual | Table of contents en | 5

Table of contents

Important safeguards..........................................................................................................................................................3

About this manual ..............................................................................................................................................................4

Safety precautions...............................................................................................................................................................4

Table of contents ................................................................................................................................................................5

1 About the equipment ........................................................................................................................................................7

1.1

Controls and indicators (front) ................................................................................................................................8

1.2

Controls and connections (LBB1930, LBB1935 - rear) ........................................................................................9

1.3

Controls and connections (LBB1938 - rear) ...........................................................................................................9

2 Internal setting (LBB1938 only) .....................................................................................................................................10

3 Installation in rack ...........................................................................................................................................................11

4 External settings and connections .................................................................................................................................12

4.1

Connect the DC supply (battery) ..........................................................................................................................12

4.2

Connecting the line input and loopthrough ........................................................................................................13

4.3

Connecting the priority input and using the control terminals (LBB1938 only) .............................................14

4.4

100 V slave input ....................................................................................................................................................15

4.5

Connecting loudspeakers .......................................................................................................................................16

4.5.1

Constant voltage loudspeakers .........................................................................................................................16

4.5.2

Low impedance loudspeakers ..........................................................................................................................17

4.6

Mains connection ....................................................................................................................................................17

5 Operation of booster amplifier ......................................................................................................................................18

6 Technical data ..................................................................................................................................................................19

6.1

Electrical ..................................................................................................................................................................19

6.2

Performance ............................................................................................................................................................19

6.3

Inputs ........................................................................................................................................................................19

6.4

Outputs .....................................................................................................................................................................20

6.5

Environmental conditions ......................................................................................................................................20

6.6

General .....................................................................................................................................................................20

Bosch Security Systems | 2003-09 | 3922 988 92983en

Plena Booster Amplifier | Installation and Operating Manual | Table of Contents en | 6

Bosch Security Systems | 2003-09 | 3922 988 92983en

Plena Booster Amplifier | Installation and Operating Manual | About the equipment

1 About the equipment

LBB1930

LBB1935 Temp.

Sensor

VU

Input

100V

70V

8Ohm

0

0

Loopthrough

100V

Slave Input 100V

0

Fuse

Power

230V

240V

DC Fuse

Power

DC In 24V

+

-

Figure 1.1

Input 1 Priority

Loopthrough 1

Input 2 Program

Loopthrough 2

LBB1938

Overheat

Temp.

Sensor

VU

100V

F701

70V

F702

0

0

100V

70V

8Ohm

0

0

Priority Only

No Priority

Input 1 Priority

2..24V - Input 1

0V - Input 2

Input 2 Enable

2..24V - Enable

0V - Mute

+

-

+

-

Slave Input 100V

100V

0

+

DC In 24V

-

Figure 1.2

Bosch Security Systems | 2003-09 | 3922 988 92983en

Delay

Power

230V

Power

DC Fuse 40A

Battery en | 7

Plena Booster Amplifier | Installation and Operating Manual | About the equipment en | 8

The Plena Booster Amplifier range consists of three mono amplifiers with output powers of 120 W (LBB1930), 240

W (LBB1935) or 480 W (LBB1938). These booster amplifiers have 70 V and 100 V constant voltage outputs and a low impedance output for 8 Ohm loudspeakers. The amplifiers are protected against overload and short circuits.

Built-in features like a temperature controlled fan and an overheat protection ensure high reliability. Battery operation with automatic switchover from the mains supply is possible. The line inputs are balanced and have a loopthrough facility; a 100 V slave input allows for connection to existing loudspeaker lines. The LBB1938 has double inputs with a priority function and priority controlled outputs.

1.1 Controls and indicators (front)

2

Plena Booster Amplifier

0 dB

1 VU meter (LED bar)

-20 dB

2 Power on indication LED (green)

4 Tone control, channel 1 to 4

Figure 1.3

1

2

Plena Booster Amplifier

0 dB

-6 dB

-20 dB

Power

5 Volume, channel 1 to 4

6 Master volume

7 Channel selection for headphone

8 Headphone connection

LBB1930

LBB1935

LBB1938

Battery Overheat

Figure 1.4

1

1 Power button

2 VU-meter (LED's for -20, -6, 0 dB and Power ON)

3 Battery operation indicator (only for LBB1938)

4 Overheat indicator (only for LBB1938)

5 Air inlet for forced air cooling (only for LBB1938)

3 4 5

Bosch Security Systems | 2003-09 | 3922 988 92983en

Plena Booster Amplifier | Installation and Operating Manual | About the equipment en | 9

1.2 Controls and connections (LBB1930, LBB1935 - rear)

LBB1930

LBB1935

230V- 240V-

100V 0V

100V

+

1

-

3

GND

2

GND

1

-

3

+

2 line in line out

100V 70V 0 0 8

24V DC IN

+

Line fuse

250V T1A

Apparatus delivered connected for 230V-

Warning

This apparatus must be earthed

1 2 3

Figure 1.5

1 Level control

2 100 V / 0 V slave input terminal

3 Line input (XLR/balanced)

4 Line input (phone jack/balanced)

5 Line loopthrough (XLR/balanced)

6 Line loopthrough (phone jack/balanced)

7 Loudspeaker output terminals and 24 Vdc power supply terminals

4 5 6 7

8 Earth connection screw

9 Mains fuse

LBB1930 T2.5A

LBB1935 T4A

10 Mains connector (3-pole)

11 Mains voltage switch 230/240 V

11

10

9

8

1.3 Controls and connections (LBB1938 - rear)

15 14 13 12

Input 1

Priority

Input 2

Enable

Slave Input

100V

Inpu t 1 Priority

Loopthrough 1

Input 2 Program

Loopthrough 2

Input 1 Priority

2..24V-Input 1

0V-Inpu t 2

Inpu t 2 Enable

2..24V-Enable

0V-Mute

+

-

+

-

Slave Input 100V 100V

0

2..24V

GND 2..24V

Default Off

GND

Default On

100V 0

Input 1-Pr iority Input 2-Program

Direct O utput

100V/70V

100V

0

70V

0

8ohm

Priority Only

0

No Priority

0

Priority

100V 0 70V 0 8

Priority ControlledO utput

Priority Only No Priority

100V 0 100V 0

Input Input

LBB1938

9

8

11

10

1 2 3 4 5 6

Figure 1.6

1 Priority line - input 1 (XLR/balanced)

2 Level control - input 1

3 Line loopthrough 1 (XLR/balanced)

4 Program line - input 2 (XLR/balanced)

5 Level control - input 2

6 Line loopthrough 2 (XLR/balanced)

7 Priority controlled loudspeaker output terminals

8 Earth connection screw

Bosch Security Systems | 2003-09 | 3922 988 92983en

7

9 24 Vdc power supply terminals

10 Mains fuse (T10A)

11 Mains connector (3-pole)

12 Loudspeaker direct output terminals

13 100 V slave input terminals

14 Input 2 enable control terminals

15 Input 1 priority control terminals

Plena Booster Amplifier | Installation and Operating Manual | Internal setting (LBB1938 only)

2 Internal setting (LBB1938 only)

en | 10

LBB1938

F701

F702

100V

70V

Figure 2.1

The output voltage of the priority controlled loudspeaker outputs can be set to 70 V or 100 V. To this end, a high power fuse inside the unit is used as a voltage selector.

Insert the high power fuse into fuse holder F701 for 100 V selection (default setting), or into fuse holder F702 for 70

V selection. This selection does not affect the output voltage of the loudspeaker direct outputs.

Caution

Never insert two fuses into F701 and F702 simultaneously.

Bosch Security Systems | 2003-09 | 3922 988 92983en

Plena Booster Amplifier | Installation and Operating Manual | Installation in rack

3 Installation in rack

LBB1930

LBB1935

1

Plena Boo

0 dB

-20 dB ster Amplifier

Power

1

Plena Boos ter Amplifier

0 dB

-20 dB

Power

1

Battery

Overhea

LBB1938 en | 11

1

Figure 3.1

The booster amplifier is delivered for tabletop use, but you can mount it in a 19" rack using the brackets supplied with the unit. In case of rack mounting, you must:

• remove the 4 feet from the bottom of the unit. Without the feet, the LBB1930 and LBB1935 are 2U high and the

LBB1938 is 3U high.

• leave 1U empty rack space above the LBB1930 or LBB1935 to ensure sufficient air flow.

• ensure that the ambient temperature of the unit in the rack does not exceed 55 °C.

In case of rack mounting, removal of the top cover of a booster amplifier is allowed to improve the ventilation. In such a case, always use the shimming washers that come with the brackets and make sure to comply with the safety instructions. The amplifier has a built-in temperature controlled fan for reliable operation at high output power for a prolonged time. If the internal temperature reaches a critical limit due to insufficient air flow, overload or an excessive ambient temperature, the overheat protection will be activated, causing the amplifier to switch to standby mode.

Bosch Security Systems | 2003-09 | 3922 988 92983en

Plena Booster Amplifier | Installation and Operating Manual | External settings and connections

4 External settings and connections

4.1 Connect the DC supply (battery)

en | 12

-

12 VDC

+

100V

70V

0

0

8

24V DC

-

IN

+

230V-

240V-

Line fus

Warning

This app aratus m e

A Appa ust be e arthed for 230

V-

F

-

12 VDC

+

8

100V

0V

100V

GND GND line out

100V 70V

230V-

240V-

24V DC

IN

Line fus

250V T1

A

Warning

This app aratus m

Apparatu s delivere

V-

LBB1930 (120W); F=F15A

LBB1935 (240W); F=F30A

Direct O utput

Rated in power : 1 put

600V

Apparatu connecte d for 230 d

V-

00V

0

70V

0

Priority

Priority

Controll only

8 ed Outp ut

No prio rity

00V 0

V

100V 0

Warning

This app aratus m ust be e arthed

24VDC

IN

-

12 VDC

+

-

12 VDC

+

Input 1-P riority

Input 1

Priority

Input 2

Enable

Slave In put

100V

Input 2-P rogram

Input

Loopthro ugh

Input

Loopthro ugh

8

Direct O utput

100V

70V

Priority

Controll ed Outp

No prio ut rity

100V 0

Rated in put power : 1 600V connecte d for 230

V-

T10L250

V

24VDC IN

100V 0

Warning aratus m ust be ea rthed

LBB1938 (480W); F=F40A

Figure 4.1

Figure 4.2

The booster amplifier has a 24 Vdc input (screw terminal), which you can use to connect a back up power supply, e.g. batteries. You can earth (8) the unit to increase the electrical stability of the system.

Caution

The connection cable must have an in-line fuse. Use the type of fuse as mentioned in the illustration.

Bosch Security Systems | 2003-09 | 3922 988 92983en

Plena Booster Amplifier | Installation and Operating Manual | External settings and connections

4.2 Connecting the line input and loopthrough

LBB1925/10

1-

4

/Line

3

5

Tel/EM

G Trigger

1 Trigger

2

0

1.Audio+

2.0V

4.24V

d.c.

/Line

5.Allca

7.Data+

LBB19

25/00

0V~,50/

60Hz

L

RS232

R

Maste rOut

CD

Out

+

GND

GND

Aux

+

100V

0

Zone 5

100V

0

Zone 1

100V

0

Zone 2

100V

0

Zone 3

Zone 6

Call Ac tive Call In

100V

0

100V

0

Zone 4 100V

DC Ou 0

DC In

100V

0

Appara connec

In tus deliv ered

115V-

+24V-

+24V-

Warnin

This ap paratus must b e earth ed

230V-

Rated input

Power

T1.0AL

: 50VA

250V

3 5

LBB1930

LBB1935

3 5

4

100V

0V

100V

GND

GND line ou

100V

70V 0

0

8

24V

DC IN

+

230V240V-

Line fuse

250V T1A

Warning paratus

Appar conn must b e earth ected ed atus del ivered for 230 V-

6

LBB1930

LBB1935

100V

0V

100V

GND

GND line out

4 6

100V

70V 0

0

8

24V

DC IN

+

230V240V-

Line

250V

Warning paratus must b fuse

T1A

Appa connec e earth ed ratus de

230V

LBB1938 LBB1938

4 6

Input 1-P riority

Input 1

Priority

Slave Inp ut

100V

Input 2-P rogram

Input

Loopthro ugh

Input

Loopthrou gh

Direct O utput

Rated power input

: 1600V

Appa connec elivere ted for d

230V-

100V

0

Priority

Priority

70V only

0

Controlle

8 d Outpu

No prio rity

100V 0

Line fu se

T10L25

0V

100V 0

Warning paratus must b e earthe d

24VDC

IN

4 6

Input 1-P riority

Input 1

Priority

Slave Inp ut

100V

Input 2-P rogram

Input

Loopthrou gh

Input

Loopthr ough

100V

0

70V

0

Priority

Priority

Controlle only

8 d Outpu

No prio rity

Rated power input

: 1600

V

Appa connec elivere ted for d

230V-

Line fu

T10L2 se

50V

24VDC

IN

100V 0

100V 0

Warning paratus must b e earth ed en | 13

Figure 4.3

The booster amplifier has a balanced line input for connection to a preamplifier or a mixer. Use the loopthrough connection to connect the booster amplifier to another booster amplifier if more power is needed. Each power amplifier must be connected to its own set of loudspeakers. Do not connect booster outputs to each other. The

LBB1930 and LBB1935 have both XLR (3 and 5) and phone jack connectors (4 and 6) for input and loopthrough.

For the LBB1938 use program line - input 2 (4) and line loopthrough 2 (6) for normal operation without priority.

Volume control

Use the volume control next to the line input to set the output level of the booster amplifier.

Bosch Security Systems | 2003-09 | 3922 988 92983en

Plena Booster Amplifier | Installation and Operating Manual | External settings and connections en | 14

4.3 Connecting the priority input and using the control terminals (LBB1938 only)

LBB1925/10

Apparatus delivered connected for 230V-

115V 230V

/Line

1-

4

3

5

3

5

2

4

1

Tel/EMG

Trigger 1 Trigger 2

LBB1925/10

890019251005

115/230V~,50/60Hz

No.

0

/Line

1. Audio+

2.0V

3.Audio-

4.24Vd.c.

5. Allcall

6.Data-

7.Data+

8.Chs.GND

PCAudoln

3

7

8

6

1

5

2

4

L

R

RS232

MasterOut

CD

Out

Aux

+

2 -

3

GND

1

GND

1 -

3

+

2

100V 0 100V 0 100V 0 100V 0

100V 0 100V 0 100V 0 100V 0 +24V+24V-

Warning

This apparatus must be earthed

Rated Input

Power : 50VA

T0.5L 250V

15 14

Input 1

Priority

Input 2

Enable

Slave Input

100V

Input 1 Prior ity

Loopthrough 1

Input 2 Program

Loopthrough 2

Input 1 Prior ity

2..24V-Input 1

0V-Input 2

Input 2 Enable

2..24V-Enable

0V-Mute

+

-

+

-

Slave Input 100V 100V

0

2...24V

GND 2...24V

GND

Default Off Default On

100V 0

Input 1-Priority Input 2-Program

Input Input

Zone 1 output

Direct Output

100V/70V

100V

0

70V

0

8ohm

Priority Only

0

No Pr iority

0

Priority

100V 0 70V 0 8

Priority Controlled Output

Priority Only N o Priority

100V 0 100V 0

LBB1938 15 14

Input 1

Priority

Input 2

Enable

Slave Input

100V

Input 1 Prior ity

Loopthrough 1

Input 2 Program

Loopthrough 2

Input 1 Prior ity

2..24V-Input 1

0V-Input 2

Input 2 Enable

2..24V-Enable

0V-Mute

+

+

-

-

Slave Input 100V 100V

0

2...24V

GND 2...24V

GND 100V

Default Off Default On

0

Input 1-Priority Input 2-Program

Input Input

Zone 2 output

Direct Output

100V/70V

100V

0

70V

0

8ohm

Priority Only

0

No Pr iority

0

Priority

100V 0 70V 0 8

Priority Controlled Output

Priority Only N o Priority

100V 0 100V 0

LBB1938

1 4 1 4 to next zones

Figure 4.4

Next to the program input (Input 2-Program) the booster amplifier LBB1938 is also provided with a balanced priority input (Input 1-Priority) for connection to another preamplifier or mixer.

Apply a control voltage of 2...24 V to the input 1 priority control terminals (15) to switch ON the priority input (1) and mute the program input (4). In this way a local music source can be connected to the program input and a remote emergency system to the priority input. The emergency source must be able to supply the 2…24 V control voltage to override the local music source. The program input can be remotely controlled by using a switch that is connected to the input 2 enable control terminals (14).

Application example for use of the LBB1938 control terminals (see fig. 4.4)

You can use up to six LBB1938 boosters in combination with the Plena LBB1925/10 System Pre-amplifier to build a powerful multi-zone sound system. Zone switching of background music and calls is done via the LBB1925/10 zone relays in combination with the LBB1938 control terminals. The LBB1925/10 controls the background music by distributing 24 Vdc via the music zone relays to the LBB1938 input 2 enable control terminals (14). The

LBB1925/10 controls the calls by distributing 24 Vdc via the call zone relays to the LBB1938 input 1 priority control terminals (15). Each booster serves one loudspeaker zone. Each zone can be OFF, or receive music or a call.

Bosch Security Systems | 2003-09 | 3922 988 92983en

Plena Booster Amplifier | Installation and Operating Manual | External settings and connections

4.4 100 V slave input

+

1

-

3

GND

2

GND

1

-

3

+

2

100V 0V

100V line in line out en | 15

LBB1930

LBB1935

230V- 240V-

100V 70V 0 0 8

24V DC IN

+

Line fuse

250V T1A

Apparatus delivered connected for 230V-

Warning

This apparatus must be earthed

Figure 4.5

15 14 13

Input 1

Pr iority

Input 2

Enable

Slave Input

100V

Input 1 Pr iority

Loopthrough 1

Input 2 Program

Loopthrough 2

Input 1 Pr iority

2..24V-Input 1

0V-Input 2

Input 2 Enable

2..24V-Enable

0V-Mute

+

+

-

-

SlaveInput 100V 100V

0

2..24V

GND 2..24V

Default Off

GND

Default On

100V 0

Input 1-Pr iority Input 2-Progr am

Input Input

Direct O utput

100V/70V

100V

0

70V

0

8ohm

Priority Only

0

No Priority

0

Priority

100V 0 70V 0 8

Priority Controlled O utput

Priority Only N o Priority

100V 0 100V 0

LBB1938

Figure 4.6

The booster amplifiers have a 100 V slave input that can be connected to an existing 100 V loudspeaker line. In this way it is easy to connect an additional booster amplifier on a remote location for more output power.

The 100 V input of the LBB1938 (13) is not affected by the control terminals for input 1 priority (15) or input 2 enable (14).

Bosch Security Systems | 2003-09 | 3922 988 92983en

Plena Booster Amplifier | Installation and Operating Manual | External settings and connections en | 16

4.5 Connecting loudspeakers

VU

LBB1930

LBB1935

100V

70V

8Ohm

0

0

100V 70V 0 0 8

24V DC IN

+

Figure 4.7

VU

LBB1938

100V

70V

8Ohm

100V

F701

70V

F702

0

0

0

0

Priority Only

No Priority

Figure 4.8

100 V

Figure 4.9

70 V

100 V 70 V

8 Ohm

8 Ohm

8 Ohm

8 Ohm

8 Ohm

4 Ohm

4 Ohm

8 Ohm

8 Ohm

4 Ohm

4 Ohm

8 Ohm

8 Ohm

8 Ohm

8 Ohm

8 Ohm

Input 2

Enable

Slave In put

100V

Input 1

-Priority

Input

Input 2

-Program

Loopth rough

Input

Loopth rough

Direct Output

100V 0 70V 0 8

Priority Controlled Output

Priority Only N o Priority

100V 0 100V 0

100V

0V

100V

GND

GND line out

100V 70V

0

0

8

24V DC

IN

+

230V-

240V-

Line fus e

T1A

Warning aratus m ust be connect earthed ed for 2 red

30V-

Direct O utput

100V

0

70V 0

8

Priority

Contro lled Ou rity tput

Rated input power : 1600

V

Apparat connec us deliv ered

230V-

Line fus e

0V

24VDC

IN

100V

0

100V

0

Warnin g paratus must be earthed

LBB1930

LBB1935

LBB1938

Priority Only No Priority

Figure 4.10

4.5.1 Constant voltage loudspeakers

The booster amplifier can drive 100 V constant voltage loudspeakers at full power (100 V) or half power (70 V).

Connect the loudspeakers in parallel and check the loudspeaker polarity for in-phase connection. The summed loudspeaker power should not exceed the rated amplifier power.

Bosch Security Systems | 2003-09 | 3922 988 92983en

Plena Booster Amplifier | Installation and Operating Manual | External settings and connections en | 17

LBB1938 only:

Ensure that the fuse for loudspeaker voltage selection is properly set (see chapter 2). The Priority Only and No

Priority outputs are controlled by a priority relay. The Priority Only output only provides priority announcements, while the No Priority output just provides the program signal and switches OFF at priority calls. You can also use the Priority Only output for 3-wire remote volume control override. In this case, ensure that the selected voltage for the Priority Only output is the same as for the direct output used.

4.5.2Low impedance loudspeakers

Connect low impedance loudspeakers to the 8 Ohm/0 terminals. This output can deliver the rated output power into an 8 Ohm load. Connect multiple loudspeakers in a series/parallel-arrangement to make the combined impedance 8 Ohm or higher. Check the loudspeaker polarity for in-phase connection.

4.6 Mains connection

11

230V-

240V70V

0

0

8

24V DC

IN

-

+

Line fus

250V T1

Warning

This appar atus mu st be

A App conne earthed aratus de cted fo livered r 230V-

0 2

Chime

1- -3

4 .5

1

R

CD

2

Aux

Line Ou t 1V

Mic/Lin

3

4

Inc

Mic/Lin

Out

In

100V

70V 0

0

8 24V DC

+

IN

230V240V-

Line fus

A

Warning aratus m ust be earthed

Apparatu ed for 2 red

30V-

LBB1930

LBB1935

Direct O utput

Rated power input

: 1600V connect ed for

V

0

70V

Priority

Priority

0

8

Controlle only d Outpu t

No prior ity

Line fuse

T10L25

0V

24VDC

IN

V 0

100V

0

Warning

This app aratus mu st be eart hed

Figure 4.11

Figure 4.12

Use the supplied mains cord to connect the system to the mains supply.

Input 1

Priority

Input 2

Enable

100V put

Input 1-P riority

Input

Input 2-P rogram

Loopthro ugh

Input

Loopthro ugh

Direct

Output

100V

0 70V

0

Priority only

8

Priority

Control

No prio rity ut

Rated power input

: 1600V

Apparat us deliver ed for 2 ed

30V-

Line fus

T10L25 0V

24VDC

IN

100V

0

100V

0

Warning paratus must be earthed

LBB1938

Note (LBB 1930 and LBB 1935 only)

If necessary set the mains voltage switch 230/240 V (11) to the required voltage using a sharp object, e.g. a small screwdriver.

Bosch Security Systems | 2003-09 | 3922 988 92983en

Plena Booster Amplifier | Installation and Operating Manual | Operation of booster amplifier

5 Operation of booster amplifier

2

Plena Booster Amplifier

0 dB

-6 dB

-20 dB

Power

LBB1930

LBB1935 en | 18

Figure 5.1

1

2

Plena Booster Amplifier

0 dB

-6 dB

-20 dB

Power

LBB1938

Battery Overheat

Figure 5.2

1 3 4 5

Upon switching ON the amplifier using the power button (1), the green Power On LED (2) lights up. The VU-bar shows the output level of the amplifier. If the internal temperature of the booster reaches a critical limit, due to poor ventilation or overload, an overheat protection circuit switches OFF the power stage.

LBB1938 only:

The overheat indicator (4) lights up if the power stage is switched OFF by the overheat protection circuit. The battery operation indicator (3) lights up if the mains power supply is failing and the back-up battery is in use.

Bosch Security Systems | 2003-09 | 3922 988 92983en

Plena Booster Amplifier | Installation and Operating Manual | Technical data

6 Technical data

6.1 Electrical

Mains voltage

LBB1930/00, LBB1935/00

LBB1930/50, LBB1935/50

LBB1938/00

Max mains power consumption

LBB1930/x0

LBB1935/x0

LBB1938/00

Max mains inrush current

LBB1930/00

LBB1930/50

LBB1935/00

LBB1935/50

LBB1938/00

Battery voltage

Max battery current

LBB1930/x0

LBB1935/x0

LBB1938/00

230/240 Vac, ±10%, 50/60 Hz

110 Vac, ±10%, 50/60 Hz

230 Vac, ±10%, 50/60 Hz

400 VA

800 VA

1600 VA

8 A

16 A

9 A

19 A

19 A

24 Vdc, +20%/-10%

6 A

11 A

30 A

6.2 Performance

Frequency response

Distortion

S/N (flat at max volume)

LBB1930/x0

LBB1935/x0

LBB1938/00

50 Hz - 20 kHz (+1/-3 dB @ -10 dB ref. rated output)

< 1% @ rated output, 1 kHz

> 80 dB

> 85 dB

> 90 dB

6.3 Inputs

Line input (3-pin XLR, 6.3 mm phone jack, balanced) - LBB1930/x0, LBB1935/x0

CMRR > 25 dB (50 Hz - 20 kHz)

Line input 1, 2 (3-pin XLR, balanced) - LBB1938/00

CMRR

100 V input (Screw, unbalanced)

> 25 dB (50 Hz - 20 kHz) en | 19

Bosch Security Systems | 2003-09 | 3922 988 92983en

Plena Booster Amplifier | Installation and Operating Manual | Technical data

6.4 Outputs

Line loopthrough output (3-pin XLR, 6.3 mm phone jack, balanced) - LBB1930/x0, LBB1935/x0

Nominal level

Impedance

1 V direct connection to line input

Line loopthrough output 1, 2 (3-pin XLR, balanced) - LBB1938/00

Nominal level

Impedance

1 V direct connection to line input

Loudspeaker outputs (Screw, floating)

Max/rated output power

70/100 V output

LBB1930/x0

LBB1935/x0

LBB1938/00

8 Ohm output

LBB1930/x0

LBB1935/x0

LBB1938/00

Output power @ 24 V battery operation

180 W/120 W

360 W/240 W

720 W/480 W

31 V (120 W)

44 V (240 W)

62 V (480 W)

-1 dB ref. rated power

6.5 Environmental conditions

Operating temperature range

Storage temperature range

Relative humidity

-10 to +55 °C

-40 to +70 °C

< 95%

6.6 General

EMC emission

EMC immunity

Acoustic noise level of fan

LBB1930/x0, LBB1935/x0

LBB1938/00

Dimensions

LBB1930/x0, LBB1935/x0

LBB1938/00

Weight

LBB1930/x0

LBB1935/x0

LBB1938/00

19” mounting brackets acc. to EN 55103-1 acc. to EN 55103-2

< 45 dB SPL @ 1 m

< 48 dB SPL @ 1 m

100 x 430 x 270 mm (19” wide, 2U high, with feet)

145 x 430 x 370 mm (19” wide, 3U high, with feet) approx. 10.5 kg approx. 12.5 kg approx. 25 kg included en | 20

Bosch Security Systems | 2003-09 | 3922 988 92983en

For more information visit www.boschsecuritysystems.com

© Bosch Security Systems B.V.

Data subject to change without notice

2003-09 | 3922 988 92983en

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • 240 W power amplifier in a 2U high housing
  • EN 54‑16 certified
  • 70 V / 100 V and 8 ohm outputs
  • Dual inputs with priority switching
  • 100 V input for slave operation on 100 V speaker line

Related manuals