N EW A NEMOMETER

Wind speed sensor to be used in conjunction with SEAV electronic control units for sun blinds.

T ECHNICAL DATA

- Contact capacity: 200 mA 100VDC

- Contact closing (pulse): Once x revolution

- Connection cable:

- Connection cable length:

- Working temperature:

outdoor use 2 x 2.5 mm2

(AWG 12-26) 4 m Max.

-10

÷

60°C

- Packaging dimensions 240x185x110 mm

- Container PC UL94V-0 (IP54)

E XPLODED D IAGRAM OF M ECHANICAL P ARTS :

GB

C

ONNECTION

C

ABLE

I

NSTALLATION

:

1 Rev. 1.1 03/07

H ORIZONTAL A NEMOMETER I NSTALLATION :

V ERTICAL A NEMOMETER I NSTALLATION :

F

OR THE

I

NSTALLER

-

IMPORTANT

- The fixing of the connection cable must be secured using the cable clamp supplied

with the product.

- At the time of installation, the anemometer must be handled with care, making sure you have assembled

its components correctly.

- It is very important that you decide on the exact position of the device so that it is affected by the wind in the same way

as the sun blind.

- All operations requiring the opening of the casing (such as installation, programming and repair, etc.) must

be carried out by skilled staff only.