Nortel Networks FastRad Telephone Installation guide
Add to my manuals
35 Pages
Nortel Networks FastRad is a device that can be used for programming, testing, and troubleshooting telecommunications equipment. It is a powerful tool that can be used by both experienced and novice users. With the FastRAD, you can quickly and easily configure and test your equipment, ensuring that it is operating at peak performance.
advertisement
855601 Cover Front Page 1 Wednesday, October 29, 1997 4:19 PM
Return to Menu
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
FastRAD
Installation Guide
•
• • • • • • • • • • • • • • • • • • • • • • • • •
855601 Cover Front Page 2 Wednesday, October 29, 1997 4:19 PM
855601 TOC Page i Wednesday, October 29, 1997 4:16 PM
Table of Contents
Canadian & US Safety Installation Instructions
For equipment with internal power supplies
For equipment with external power supplies
Important Safety Instructions
Canadian Regulations
Industry Canada Notice
US Regulations
Federal Communication Commission (FCC) Notice
Introduction
Before you start
Special check list
Requirements for PC communication
Connecting the FastRAD
Mounting the FastRAD
Programming the FastRAD
Starting a programming session
General Programming
Programming Alarm Reporting
10
11
6
8
13
14
4
5
1
3 iv iv iii iii ii i i i
FastRAD Installation Guide
855601 TOC Page ii Wednesday, October 29, 1997 4:16 PM ii Table of Contents
Testing the FastRAD
Troubleshooting
Programming Record
20
21
22
FastRAD Installation Guide
855601 Book : 855601 FCC Page i Wednesday, October 29, 1997 3:52 PM
i
Canadian & US Safety Installation Instructions
Please Read Carefully
WARNING
: To avoid electrical shock hazard to personnel or equipment damage observe the following precautions when installing telephone equipment:
1.
Never install telephone wiring during a lightning storm.
2.
Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.
3.
Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.
4.
Use caution when installing or modifying telephone lines.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
This symbol (if applicable) on the product is used to identify the following important information:
For equipment with internal power supplies:
•
• Mains nominal AC voltage 110-120 V~ ; 50/60 Hz
Mains nominal AC voltage 220-240 V~ ; 50/60 Hz
For equipment with external power supplies:
• Must be powered from a CSA certified and UL listed or CSA-NRTL/C certified Class 2 power source equipped with an appropriate mating connector. Please refer to installation instructions for details.
For current ratings, refer to product specific documentation and product labels.
FastRAD Regulations
855601 Book : 855601 FCC Page ii Wednesday, October 29, 1997 3:52 PM ii
Important Safety Instructions
Please Read Carefully
When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury of persons, including the following:
1.
Read and understand all instructions
.
2.
Follow the warnings and instructions marked on the product.
3.
Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.
4.
Do not use this product near water, for example, near a bathtub, wash bowl, kitchen sink, or laundry tub, in a wet basement or near a swimming pool.
5.
Do not place this product on an unstable cart, stand or table. The product may fall, causing serious damage to the product.
6.
This product should never be placed near or over a radiator or heat register. This product should not be placed in a built-in installation unless proper ventilation is provided.
7.
Do not allow anything to rest on the power cord. Do not locate this product where the cord will be abused by persons walking on it.
8.
Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock.
9.
Never spill liquid of any kind on the product.
10.
To reduce the risk of electric shock, do not disassemble this product, but have it sent to a qualified service person when service or repair work is required.
11.
Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions: a. When the power supply cord or plug is damaged or frayed.
b. If the product has been exposed to rain, water or liquid has been spilled on the product, disconnect and allow the product to dry out to see if still operates; but do not open up the product.
c. If the product housing has been damaged.
d. If the product exhibits a distinct change in performance.
12.
Avoid using telephone equipment during an electrical storm. There may be a remote risk of electric shock from lightning.
13.
Do not use the telephone equipment to report a gas leak in the vicinity of the leak.
14.
CAUTION
: To eliminate the possibility of accidental damage to cords, plugs, jacks, and the telephone equipment, do not use sharp instruments during the assembly procedures.
15.
Save these instructions
.
FastRAD Regulations
855601 Book : 855601 FCC Page iii Wednesday, October 29, 1997 3:52 PM
iii
Canadian Regulations
Industry Canada Notice — Please Read Carefully
The Industry Canada label identifies Public Switched Telephone Network (PSTN) certified equipment.
This certification means that the equipment meet certain telecommunications network protective, operational and safety requirements. Industry Canada does not guarantee the equipment will operate to the user's satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.
Existing telecommunications company requirements do not permit their equipment to be connected to customer provided jacks except where specified by individual telecommunications company tariffs.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
WARNING
: Users should not attempt to make electrical ground connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.
NOTICE
: The Ringer Equivalence Number (REN) assigned denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. Please refer to the installation instructions with the KSU for more details.
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations as specified in the Industry Canada Standard ICES-003 Issue 2.
Substitution of non-approved equipment will void the Nortel warranty.
Address for warranty and repairs in Canada
:
Nortel Networks
30 Norelco Drive
Weston, Ontario
M9L 2X6
For more information call 1-800-4NORTEL.
FastRAD Regulations
855601 Book : 855601 FCC Page iv Wednesday, October 29, 1997 3:52 PM iv
US Regulations
Federal Communication Commission (FCC) Notice —
Please Read Carefully
Radio/TV Interference
: This equipment, classified as a digital apparatus, generates radio frequency interference and if not installed and used properly in strict accordance with the manufacturer's instructions may cause interference with receiving mediums. This Class A equipment complies with Part 15 of the
FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation. While these rules are designed to provide reasonable protection, there is no guarantee that interference will not occur in a particular installation. You can determine whether interference occurs by monitoring your receiving device while the equipment is connected and a phone call in place.
If problems are experienced:
•
• Reorient or relocate the receiving TV or radio antenna, where this may be done safely.
To the extent possible, move the telephone system and the radio or television farther away from each other or connect the telephone system and the radio or television to outlets on separate circuits.
• Consult the dealer or an experienced radio/television technician for additional suggestions.
Note
: FCC registration does not constitute an expressed or implied guarantee of performance.
For Devices Intended to be Connected to the Public Switched Telephone Network:
FCC Registration Number
: This telephone equipment complies with Part 68, FCC Rules for connection to the Public Switched Telephone Network (The FCC registration number appears on a label affixed to the
KSU).
Your connection to the telephone line must comply with these FCC Rules:
• Use only an FCC Standard network interface jacks and FCC compliant line cord and plug to connect this equipment to premise wiring.
If a network interface jack is not already installed in your location, you can order one from your telephone company.
Please refer to your Owner’s Manual/User’s Guide for specific installation instructions.
FastRAD Regulations
855601 Book : 855601 FCC Page v Wednesday, October 29, 1997 3:52 PM
v
US Regulations continued
In some states, customers are permitted to install their own jacks.
• The equipment may not be connected to a party line or coin /toll telephone line. Connection to
Party Line Service is subject to state tariffs. (Contact the state public utility commission, public service commission or corporation commission for information).
It is no longer necessary to notify the Telephone Company of your system’s Registration and REN numbers. However, you must provide this information to the telephone company if they request it.
• If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. If advance notice is not practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it necessary.
•
•
The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service.
Do not attempt to repair this equipment yourself. If trouble is experienced with this equipment, please refer to the repair and warranty information, noted below. If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved.
Signaling Method
: The equipment allows signaling in DTMF tones. It can complete calls to local and long distance lines and can also complete long distance calls via computer phone systems such as MCI or
SPRINT. This equipment is capable of providing access to interstate providers of operator services through the use of access codes. Modification of this equipment by call aggregators to block access dialing codes is a violation of the Telephone Operator Consumers Act of 1990.
Ringer Equivalence Number
: The FCC Registration information on the product label, includes a Ringer
Equivalence Number (REN) which is used to determine the number of devices you may connect to your phone line. Please refer to the installation instructions with the KSU for more details.
Hearing Aids
: The telephone station sets are compatible with hearing aids equipped with an appropriate telecoil and is compliant with the requirements of the Americans with Disabilities Act (ADA).
Programming Emergency Numbers
: When programming emergency numbers and/or making test calls to emergency numbers:
1.
Remain on the line and briefly explain to the dispatcher the reason for calling before hanging up.
2.
Perform such activities in the off-peak hours, such as early mornings or late evenings.
Substitution of non-approved equipment will void the NORTEL warranty.
Address for warranty and repairs in the US
:
Nortel Networks
640 Massman Drive
Nashville TN 37210
For more information call 1-800-4NORTEL
FastRAD Regulations
855601 Book : 855601 FCC Page vi Wednesday, October 29, 1997 3:52 PM vi
FastRAD Regulations
855601 Book : 855601 Guide Page 1 Wednesday, October 29, 1997 4:06 PM
Introduction
1
The Norstar
Fast Remote Access Device
(FastRAD) allows a personal computer (PC) running
Norstar ICS Remote Tools
(ICSRT) to communicate with a Key Service Unit (KSU). FastRAD also runs with
Companion Diagnostics System
(CDS) and
Companion Manager
. The FastRAD:
• is located on site near either the KSU or the PC
• receives calls from a PC via modem or PC direct connection
• authorizes a PC to access a KSU
• connects a PC with the KSU
• reports KSU alarms to an off-site alarm center
Refer to Figure 1.
FastRAD Installation Guide
855601 Book : 855601 Guide Page 2 Wednesday, October 29, 1997 4:06 PM
2
Teladapt Jack
Norstar
KSU
FastRAD
Distribution
block
At the remote site, the external line is connected to the
FastRAD through a KSU line.
PSTN
The FastRAD and the modem are connected through the telephone network.
ICSRT PC
Figure 1 – System overview of remote connection
Modem
FastRAD Installation Guide
855601 Book : 855601 Guide Page 3 Wednesday, October 29, 1997 4:06 PM
Before you start
3
❑
❑
❑
❑
Make sure you read and follow the instructions in this guide.
Make sure you have the necessary tools to complete the installation. A Special parts check list is provided in this guide.
Make sure all equipment in the FastRAD package is accounted for. A Package check list is provided in this guide.
Make sure the necessary environment and electrical conditions are met. An Environment check list and list of
Electrical requirements are provided in this guide.
Important
: Only one FastRAD can be connected to a KSU.
Environment check list
The FastRAD installation area should be:
❑
❑
❑
❑
❑
❑ clean, free of dust, dry and well ventilated between 0
°
and 50
°
Celsius (32
°
to 122
°
Fahrenheit) non-condensing relative humidity between 5% and 95% within 800 m (2600 feet) of the Norstar KSU
Note
: When using a Norstar 3X8 KSU the FastRAD must be installed within 305 m (1000 feet).
free of Bridge taps on the FastRAD KSU TCM loop free of Loading coils on the FastRAD KSU TCM loop
Package check list
Make sure the package contains:
❑
❑
❑
❑ the Norstar FastRAD an RJ-11 teladapt cord a power supply with a barrel connector a paper template (for mounting)
FastRAD Installation Guide
855601 Book : 855601 Guide Page 4 Wednesday, October 29, 1997 4:06 PM
4
Special check list
To begin an installation you need:
❑
❑
❑
❑
❑
❑
❑
❑ an operating Nortel two-line display telephone for programming the FastRAD a screwdriver two round head, size #8 wood screws, 1 inch long a roll of tape (or four tacks) for mounting the template a list of programming parameters for the FastRAD a unique System identification (ID) number a unique password the software and documentation package
*
Electrical requirements
Make sure the following electrical requirements are met:
❑ line voltage (120 V): 102 - 127 Vac
*
If you are using a PC at the site to test the FastRAD installation, this package is required.
FastRAD Installation Guide
855601 Book : 855601 Guide Page 5 Wednesday, October 29, 1997 4:06 PM
5
Requirements for PC communication
A PC communicates with a FastRAD either through a modem or through an RS-232 cable. A modem is used when the PC is situated at a remote location. An RS-232 cable is used when the
PC is situated near the FastRAD at the customer site.
When you use a PC at the customer site, you must use a 9-pin cable to connect the PC to the RS-232 port on the FastRAD.
This connector is not supplied with the FastRAD. Table 1 shows which pins are used to make a connection with the FastRAD.
Note
: The FastRAD modem supports V.32/V.32bis protocols only. We recommend a baud rate* of 9600 or greater be selected when connecting Norstar PC applications to the
FastRAD remotely using a modem.
*Refers to the PC-Modem DTE speed.
Pin Name
1 DCD
8
9
6
7
4
5
2
3
DSR
RTS
CTS
RI
RXD
TXD
DTR
GND
Function
Data Carrier Detect
Received Data
Transmitted Data
Data Terminal Ready
Ground
Data Set Ready
Request to Send
Clear to Send
Ring Indicator
Table 1 – RS-232 Pin configuration
Direction
from FastRAD from
FastRAD to
FastRAD
to
FastRAD from
FastRAD to
FastRAD from
FastRAD from
FastRAD
FastRAD Installation Guide
855601 Book : 855601 Guide Page 6 Wednesday, October 29, 1997 4:06 PM
6
Connecting the FastRAD
When equipment and environment conditions have been verified, you can begin connecting the FastRAD to the distribution block.
Before you connect the FastRAD, make sure the port works.
Attach a working Norstar two-line display telephone to the port.
If the telephone operates, the port is working.
To connect the FastRAD:
1.
Plug the barrel connector of the power supply into the power connector of the FastRAD and the other end into the wall outlet. See Figure 2.
This unit must be powered from a pluggable
Type A Class 2 power source that is UL and
CSA listed.
2.
Check that the LED on the FastRAD unit is lit to confirm the power connection.
3.
Locate the distribution block.
4.
Mount the RJ-11 teladapt jack next to the distribution block.
5.
Using twisted pair station wire, connect the teladapt jack to a free station port at the distribution block.
Note
: Do not connect the FastRAD to port 101. This port is reserved for the prime set. The FastRAD should be connected to one of the on-core station ports.
FastRAD Installation Guide
855601 Book : 855601 Guide Page 7 Wednesday, October 29, 1997 4:06 PM
7
TCM Port DB-9 Pin
Connector
LED
Barrel Power
Supply Plug
Figure 2 – KSU connection
6.
Connect one end of the RJ-11 teladapt cord to the TCM port on the side panel of the FastRAD. See Figure 2.
7.
Connect the other end to the RJ-11 teladapt jack to the
KSU. Make sure the cord is less than 800 m (2600 feet) long.
Note
: A connection to the FastRAD DB-9 pin serial port is only required for a direct connection to a PC at the site.
FastRAD Installation Guide
855601 Book : 855601 Guide Page 8 Wednesday, October 29, 1997 4:06 PM
8
Mounting the
FastRAD
Before you mount the FastRAD, select a location within 800 m
(2600 feet) of the distribution block that is free of traffic, dust and dampness.
Note
: You do not need to mount the FastRAD on the wall if it is only being used temporarily to program the KSU.
The FastRAD can be mounted either horizontally or vertically.
To mount the FastRAD on the wall:
1.
Attach the paper mounting template to the wall. Make sure the template is even with the wall. See Figure 3.
Note
: This template is found at the center of this guide.
130 mm (5.25 in)
130 mm (5.25 po) 130 mm (5.25 pulg)
PO
Figure 3 – Paper wall mounting template
FastRAD Installation Guide
855601 Book : 855601 Guide Page 9 Wednesday, October 29, 1997 4:06 PM
9
2.
Put the two screws in the wall leaving 10 mm (3/8 in) of each screw exposed. The marks on the template show where the two screws are placed. After the screws are in place, remove the paper template.
Figure 4 – Mounting the FastRAD
3.
Place the two keyhole slots at the back of the FastRAD over the screws and slide the FastRAD onto the screws.
When the FastRAD is securely mounted, you are ready to start programming.
FastRAD Installation Guide
855601 Book : 855601 Guide Page 10 Wednesday, October 29, 1997 4:06 PM
10
Programming the FastRAD
Before you start, make sure you have completed the
FastRAD
Programming Record
found at the end of this guide. This record must include the System ID, Auto-answer line number and Alarm reporting line number.
Table 2 shows the different programming parameters and their default values. If your programming information does not specify a value for one of the fields, assign it to the default value.
Note
: You must program the Required fields for the FastRAD to operate. Also program any Optional fields that apply to your system. Auto-answer should be set to ON if unassisted remote access to the FastRAD is desired.
Programming Field Range
Password
System ID
Auto-answer line number
8 to 10 digits
Up to 10 digits
1 - 999
Alarm reporting line number 1 - 999
Local baud rate
Auto report alarms
300/1200/2400/4800/
9600/19200
ON, OFF
Alarm number 1
Alarm number 2 up to 16 digits up to 16 digits
Retry delay
Number of retries
Alarm reporting baud rate
Alarm reporting parity
Auto-answer
Answer delay
1 - 99 minutes
0 - 9
Low/Medium/High
None/Odd/Even
ON, OFF
6 to 60 seconds
Required / Optional
Required
Default
none
Optional blank
Required for auto-answering Line 001
Required for alarm reporting Line 001
Optional 9600
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
OFF blank blank
15 minutes
5
High
None
OFF
18 seconds
Table 2 – Programming parameters and default values
FastRAD Installation Guide
855601 Book : 855601 Guide Page 11 Wednesday, October 29, 1997 4:06 PM
Starting a programming session
11
The FastRAD cannot be used for remote or direct connections until the user password has been programed through Feature
9**. This initial password programming must occur on-site.
IMPORTANT
: There is no way to recover a lost or forgotten password or return to the default state.
A FastRAD is programmed from a Norstar two-line display telephone that is connected to the KSU. Programming information is entered into the FastRAD using the dialpad on the telephone.
Follow the prompts that appear on the display.
Note
: You cannot start a programming session while you are on a call. When a programming session is in progress, press only the buttons indicated. The programming session is terminated when you press incorrect buttons or when you make or answer a call. Only on a DR2 KSU can you put the programming session on hold to make or answer a call.
If you need to go back a step while you are programming, press
BACK or press
® and start again. If you stop programming for more than three minutes, the display returns to the date and time, and you must restart programming from the beginning.
IMPORTANT
: You must wait 60 seconds before you attempt to program the FastRAD when: the FastRAD is connected or restarted; the power supply is disconnected or the KSU is restarted.
To start a programming session:
1.
Press
ƒ·••
.
The display shows:
Password
EXIT CHNG NEXT
Note
: When the password has been changed, the display shows:
Enter password
. Check the FastRAD installation wiring and start again if the display shows:
Inactive feature
. For more information, refer to
Troubleshooting
, later in this guide.
FastRAD Installation Guide
855601 Book : 855601 Guide Page 12 Wednesday, October 29, 1997 4:06 PM
12
2.
Press
CHNG
to change your programming password.
Using the dialpad, enter your new password. Your password must be from eight to 10 characters long. As you enter your password, the display shows asterisks. The display changes to show:
Confirm password
. When you re-enter your password, asterisks appear on the display.
Note
: We recommend you assign a password the first time you start a programming session. You must assign a password before you can perform remote access. Write down your password, keep it in a safe place and avoid giving it to co-workers. This password can be changed at any time.
3.
Press
OK
to accept your new password. The display changes to show
Password
again.
4.
Press
NEXT
.
The display shows:
RAD Admin
GEN ALARM DATA
The RAD Admin display is the main programming display. This display must appear on the telephone before you can begin to program the FastRAD.
FastRAD Installation Guide
855601 Book : 855601 Guide Page 13 Wednesday, October 29, 1997 4:06 PM
General
Programming
13
General programming allows you to define the System ID number.
Before you begin entering general programming information, make sure the display shows
RAD Admin
. If you do not have this display on the Norstar telephone, follow the steps in
Starting a Programming Session
.
To enter general FastRAD programming information:
1.
Press
GEN
.
The display shows:
System ID number
BACK SHOW NEXT
2.
Press
SHOW
.
The display shows:
-
BACK CHNG NEXT
Note
: If this is a first time installation, we recommend the system ID number must be programmed to allow remote access. If this is not a first time installation, the display shows the last System ID entered.
3.
Press
CHNG
.
The display shows:
-
CLEAR BKSP OK
4.
Using the dialpad, enter the System ID number.
Note
: If you enter a wrong number, press
BKSP to delete the last number entered, or CLEAR to erase all numbers entered.
5.
Press OK to accept the System ID number.
This completes general programming. To continue programming alarm reporting, refer to the next section, Programming
Alarm Reporting.
FastRAD Installation Guide
855601 Book : 855601 Guide Page 14 Wednesday, October 29, 1997 4:06 PM
14
Programming
Alarm
Reporting
The alarm programming session allows you to program the
FastRAD to report alarms to the telephone number of a dedicated alarm center, such as a printer or terminal.
Before you begin an alarm programming session, make sure the display shows RAD Admin.
If you do not have this display on the Norstar telephone, follow the steps listed in Starting a Programming Session.
To program the FastRAD Alarm Reports:
1.
Press ALARM.
The display shows:
Auto-report: OFF
BACK CHNG NEXT
2.
Press CHNG to turn automatic alarm reporting on.
The display shows:
Auto-report: ON
BACK CHNG NEXT
3.
Press NEXT.
The display shows:
Report line: 001
BACK CHNG NEXT
4.
Press CHNG.
The display shows:
Report line:_
CLEAR BKSP OK
5.
Enter the KSU line number the FastRAD uses for remote connections. Refer to the Programming Record for the correct line number.
6.
Press NEXT.
The display shows:
Alarm number 1
BACK SHOW NEXT
7.
Press SHOW to see where the FASTRAD reports its alarms.
The display shows:
<Alarm number>
BACK CHNG NEXT
FastRAD Installation Guide
855601 Book : 855601 Guide Page 15 Wednesday, October 29, 1997 4:06 PM
15
8.
Press CHNG to enter the first alarm report telephone number.
The display shows:
-
CLEAR BKSP OK
9.
Enter the telephone number for Alarm 1.
The display shows:
<alarm number>
CLEAR BKSP OK
10. Press OK.
The display shows:
Alarm number 2
BACK SHOW NEXT
11. Press SHOW.
The display shows:
<Alarm number>
BACK CHNG NEXT
If you do not want to enter a second alarm number, press
NEXT and go to step 14.
12. Press CHNG.
The display shows:
_
CLEAR BKSP OK
13. Enter the telephone number for Alarm 2.
14. Press OK.
The display shows:
Num retries: 5
BACK CHNG NEXT
Note: If you are using the default setting(s), press NEXT and go to step 18.
15. Press CHNG.
The display shows:
Num retries:_
CLEAR BKSP OK
16. Enter the number of retries. This must be a number between 0 and 9.
FastRAD Installation Guide
855601 Book : 855601 Guide Page 16 Wednesday, October 29, 1997 4:06 PM
16
17. Press OK.
The display shows:
Retry mins: 15
BACK CHNG NEXT
18. Press CHNG.
The display shows:
Retry mins:_
CLEAR BKSP OK
19. Enter the number of minutes between retries. This must be a number between 1 and 99.
20. Press OK.
The display shows:
Alarm baud: High
BACK CHNG NEXT
21. To change the baud rate, press CHNG until the desired baud rate appears. The baud rate should match that of the alarm device’s modem. You have three choices: Low, Medium and High. The default is High.
IMPORTANT: Changing the baud rate is not required unless the alarm centre modem is connected to a slow device, such as an old printer. Selecting the Low setting limits the baud rate to less than 300. Selecting the Medium setting limits the baud rate to less than 1200. Selecting the
High setting, the baud rate is determined entirely by the
FastRAD and the alarm centre modems.
22. Press NEXT.
The display shows:
Parity: None
BACK CHNG NEXT
23. To change the parity setting, press CHNG until the desired setting appears. The parity should match that of the alarm device’s modem. You have three choices: None, Odd and
Even. The default is None.
24. Press NEXT.
The display shows:
RAD Admin
GEN ALARM DATA
FastRAD Installation Guide
855601 Book : 855601 Guide Page 17 Wednesday, October 29, 1997 4:06 PM
17
This completes alarm programming. To continue programming
FastRAD call handling, refer to the next section, Programming
Data.
Programming
Data
Data programming allows you to determine how many seconds the FastRAD waits before answering a call on an incoming KSU line. This allows a line to be used normally during business hours and provides Auto-answer capabilities after hours. Autoanswer must be set to ON to allow unassisted access to the
FastRAD.
Before you begin programming, make sure the display shows
RAD Admin.
If you do not have this display on the Norstar telephone, follow the steps in Starting a Programming Session.
To program the FastRAD’s Data:
1.
Press DATA.
The display shows:
Auto-answer: OFF
BACK CHNG NEXT
2.
Press CHNG to turn automatic answer ON.
The display shows:
Auto-answer: ON
BACK CHNG NEXT
3.
Press NEXT.
The display shows:
Answer line: 001
BACK CHNG NEXT
4.
Press CHNG.
The display shows:
Answer line:_
CLEAR BKSP OK
5.
Enter the KSU line number the FastRAD uses for remote connections. Refer to the Programming Record for the correct line number.
FastRAD Installation Guide
855601 Book : 855601 Guide Page 18 Wednesday, October 29, 1997 4:06 PM
18
Note: In general, the following points should be considered while choosing the FastRAD Auto-answer line:
• If possible, use an on-core line for auto-answering.
This allows remote access to the KSU even in the event of an expansion module failure.
• Use a line that is not often used for other purposes, since the FastRAD will auto-answer after a preprogrammed delay.
• Choose only lines that are enabled.
6.
Press OK.
The display shows:
Answer delay: 18
BACK CHNG NEXT
7.
Press CHNG to change the number of seconds the FastRAD waits before answering an incoming data call.
The display shows:
Answer delay:_
CLEAR BKSP OK
8.
Enter the number of seconds you want the FastRAD to wait prior to answering an incoming data call. This number must be between 6 and 60.
Note: The modem “wait for carrier delay” (S Register 7) must be longer than the time it takes for the modem to dial the FastRAD Auto-answer line plus the Answer delay time. For example, if it takes 10 seconds for the modem to dial in to the FastRAD and Answer delay is set to 50 seconds, then the modem “wait for carrier delay” must be greater than 60 seconds.
9.
Press OK.
The display shows:
Local baud: 9600
BACK CHNG NEXT
FastRAD Installation Guide
855601 Book : 855601 Guide Page 19 Wednesday, October 29, 1997 4:06 PM
19
10. Press CHNG until the display shows the desired local serial port baud rate (300, 1200, 2400, 4800, 9600 or 19200).
Note: To use Norstar Manager in a direct connection, the local baud rate must be set to 9600 baud.
11. Press NEXT.
The display shows:
RAD Admin
GEN ALARM DATA
12. Press
® to end programming.
The FastRAD programming is completed. You must now test the FastRAD to make sure it is operating properly.
FastRAD Installation Guide
855601 Book : 855601 Guide Page 20 Wednesday, October 29, 1997 4:06 PM
20
Testing the
FastRAD
After the FastRAD installation and on site programming are completed you should test the FastRAD data transfer capabilities. To test the FastRAD, make a connection between the PC running ICSRT and the KSU at the customer site.
If the PC is not located at the customer site and the FastRAD is not programmed with Auto-answer ON, you must phone the
ICSRT operator and instruct the operator to establish a connection with the FastRAD. In this case, refer to
Rerouting a call to the FastRAD.
If you are using a PC at the work site, refer to ICS Remote Tools
User Guide for instructions about connecting to the RAD.
The test is passed when the remote or local PC establishes a connection with the KSU.
If the FastRAD is programmed to report alarms, you can test alarm calls by disconnecting the FastRAD power supply. After a few seconds, reconnect the power supply. The FastRAD reports an alarm to the specified alarm connection centers.
Rerouting a Call to the FastRAD
If the FastRAD is not set up to Auto-answer a Central Office
(CO) line, ask the ICSRT user to set up an operator assisted-call to your site. If the operator-assisted call is not accepted by the
FastRAD, ensure the FastRAD is not involved in a programming session. Then ask the ICSRT user to attempt another operatorassisted call.
FastRAD Installation Guide
855601 Book : 855601 Guide Page 21 Wednesday, October 29, 1997 4:06 PM
21
Troubleshooting
Troubleshooting the FastRAD installation is needed if you start a programming session and the display shows
Inactive feature.
1.
Check the wiring at the distribution block.
2.
Make sure the Norstar port that the FastRAD is attached to is working.
3.
Check that the power LED on the FastRAD unit is lit to confirm the power connection.
4.
Refer to the appropriate Norstar Installer Guide for further diagnostic tests.
Note: If the wiring at the distribution block has been disconnected, the FastRAD can take up to two minutes to reset after the wiring is reconnected.
After you have checked all the wiring:
1.
Press
ƒ·••.
The display should show:
Enter password
EXIT CHNG NEXT
2.
Press NEXT.
The display shows:
RAD Admin
GEN ALARM DATA
If the display is still showing Inactive feature, repackage the FastRAD, and return it to the point of purchase.
FastRAD Installation Guide
855601 Book : 855601 Guide Page 22 Wednesday, October 29, 1997 4:06 PM
22
Programming
Record
Complete the FastRAD Programming Record before you start programming.
FastRAD Programming Record
Work Site: _______________________________________________________________
Address: ________________________
________________________
________________________
Telephone Number: __________________
Installation Date: __________________
Installer: __________________
Notes: _______________________________________________________________
GENERAL
Enter the System ID number. (Disable Admin if required.) System ID
Number __________
ALARM
Auto- report
Off
On
❑
❑
Report
Line __________
Alarm
Number 1 __________
Choose if you want the FastRAD to report alarms. The default is
Off.
Enter the line number. Enter a number between 001 and 999.
The default is 001.
Enter the telephone number of the device where the FastRAD reports alarms.
Alarm
Number 2 __________
Retry
Delay __________
Number of Retries __________
Alarm
Baud
Parity
Low
Medium
High
❑
❑
❑
None
Odd
Even
❑
❑
❑
DATA
Autoanswer
Answer
Line
Off
On
❑
❑
__________
Enter the telephone number of a second device where the
FastRAD reports alarms.
Enter the number of minutes the FastRAD waits before it retries to report an alarm. Enter a number between 1 and 99.
Enter how many times a FastRAD tries to send an alarm after a failed connection attempt. Enter a number between 0 and 9.
Choose the alarm baud number. The default is High.
Choose which parity setting the FastRAD uses. The default is
None.
Choose if you want the FastRAD to answer incoming calls
(must be ON to allow remote, unassisted access). The default is
Off.
Enter the line number. An on-core KSU line is recommended.
Enter a number between 001 and 999. The default is 001.
FastRAD Installation Guide
855601 Book : 855601 Guide Page 23 Wednesday, October 29, 1997 4:06 PM
23
Answer
Delay
Local
Baud Rate
__________
300
1200
2400
4800
9600
19200
❑
❑
❑
❑
❑
❑
Enter the number of seconds the FastRAD waits before answering a call. Enter a number between 6 to 60. The default is 18.
Choose the baud rate the FastRAD uses for the RS-232 port.
The default is 9600.
FastRAD Installation Guide
855601 Book : 855601 Guide Page 24 Wednesday, October 29, 1997 4:06 PM
24
FastRAD Installation Guide
855601 Cover Back Page 25 Wednesday, November 12, 1997 10:16 AM
1-800-4NORTEL www.nortel.com/norstar
Norstar is a trademark of Nortel Networks .
Printed in Canada
P0855601 Issue 0 5
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Key Features
- Easy to use: The FastRAD has a user-friendly interface that makes it easy to navigate and use.
- Versatile: The FastRAD can be used to program, test, and troubleshoot a wide variety of telecommunications equipment.
- Portable: The FastRAD is a portable device that can be easily transported to different locations.
- Powerful: The FastRAD is a powerful tool that can be used to perform a variety of tasks, including configuration, testing, and troubleshooting.
- Reliable: The FastRAD is a reliable device that can be used to perform critical tasks with confidence.
- Accurate: The FastRAD is an accurate device that can be used to obtain precise results.
- Fast: The FastRAD is a fast device that can be used to perform tasks quickly and efficiently.
Related manuals
Frequently Answers and Questions
What are the requirements for PC communication?
How do I connect the FastRAD?
How do I program the FastRAD?
advertisement