FastRAD

Installation Guide

• • • • • • • • • • • • • • • • • • • • • • • • •

855601 Cover Front Page 2 Wednesday, October 29, 1997 4:19 PM

855601 TOC Page i Wednesday, October 29, 1997 4:16 PM

Table of Contents

Canadian & US Safety Installation Instructions

For equipment with internal power supplies

For equipment with external power supplies

Important Safety Instructions

Canadian Regulations

Industry Canada Notice

US Regulations

Federal Communication Commission (FCC) Notice

Introduction

Before you start

Special check list

Requirements for PC communication

Connecting the FastRAD

Mounting the FastRAD

Programming the FastRAD

Starting a programming session

General Programming

Programming Alarm Reporting

10

11

6

8

13

14

4

5

1

3 iv iv iii iii ii i i i

FastRAD Installation Guide

855601 TOC Page ii Wednesday, October 29, 1997 4:16 PM ii Table of Contents

Testing the FastRAD

Troubleshooting

Programming Record

20

21

22

FastRAD Installation Guide

855601 Book : 855601 FCC Page i Wednesday, October 29, 1997 3:52 PM

i

Canadian & US Safety Installation Instructions

Please Read Carefully

WARNING

: To avoid electrical shock hazard to personnel or equipment damage observe the following precautions when installing telephone equipment:

1.

Never install telephone wiring during a lightning storm.

2.

Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.

3.

Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.

4.

Use caution when installing or modifying telephone lines.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.

This symbol (if applicable) on the product is used to identify the following important information:

For equipment with internal power supplies:

• Mains nominal AC voltage 110-120 V~ ; 50/60 Hz

Mains nominal AC voltage 220-240 V~ ; 50/60 Hz

For equipment with external power supplies:

• Must be powered from a CSA certified and UL listed or CSA-NRTL/C certified Class 2 power source equipped with an appropriate mating connector. Please refer to installation instructions for details.

For current ratings, refer to product specific documentation and product labels.

FastRAD Regulations

855601 Book : 855601 FCC Page ii Wednesday, October 29, 1997 3:52 PM ii

Important Safety Instructions

Please Read Carefully

When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury of persons, including the following:

1.

Read and understand all instructions

.

2.

Follow the warnings and instructions marked on the product.

3.

Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.

4.

Do not use this product near water, for example, near a bathtub, wash bowl, kitchen sink, or laundry tub, in a wet basement or near a swimming pool.

5.

Do not place this product on an unstable cart, stand or table. The product may fall, causing serious damage to the product.

6.

This product should never be placed near or over a radiator or heat register. This product should not be placed in a built-in installation unless proper ventilation is provided.

7.

Do not allow anything to rest on the power cord. Do not locate this product where the cord will be abused by persons walking on it.

8.

Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock.

9.

Never spill liquid of any kind on the product.

10.

To reduce the risk of electric shock, do not disassemble this product, but have it sent to a qualified service person when service or repair work is required.

11.

Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions: a. When the power supply cord or plug is damaged or frayed.

b. If the product has been exposed to rain, water or liquid has been spilled on the product, disconnect and allow the product to dry out to see if still operates; but do not open up the product.

c. If the product housing has been damaged.

d. If the product exhibits a distinct change in performance.

12.

Avoid using telephone equipment during an electrical storm. There may be a remote risk of electric shock from lightning.

13.

Do not use the telephone equipment to report a gas leak in the vicinity of the leak.

14.

CAUTION

: To eliminate the possibility of accidental damage to cords, plugs, jacks, and the telephone equipment, do not use sharp instruments during the assembly procedures.

15.

Save these instructions

.

FastRAD Regulations

855601 Book : 855601 FCC Page iii Wednesday, October 29, 1997 3:52 PM

iii

Canadian Regulations

Industry Canada Notice — Please Read Carefully

The Industry Canada label identifies Public Switched Telephone Network (PSTN) certified equipment.

This certification means that the equipment meet certain telecommunications network protective, operational and safety requirements. Industry Canada does not guarantee the equipment will operate to the user's satisfaction.

Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.

Existing telecommunications company requirements do not permit their equipment to be connected to customer provided jacks except where specified by individual telecommunications company tariffs.

Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.

Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.

WARNING

: Users should not attempt to make electrical ground connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.

NOTICE

: The Ringer Equivalence Number (REN) assigned denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. Please refer to the installation instructions with the KSU for more details.

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment

Regulations as specified in the Industry Canada Standard ICES-003 Issue 2.

Substitution of non-approved equipment will void the Nortel warranty.

Address for warranty and repairs in Canada

:

Nortel Networks

30 Norelco Drive

Weston, Ontario

M9L 2X6

For more information call 1-800-4NORTEL.

FastRAD Regulations

855601 Book : 855601 FCC Page iv Wednesday, October 29, 1997 3:52 PM iv

US Regulations

Federal Communication Commission (FCC) Notice —

Please Read Carefully

Radio/TV Interference

: This equipment, classified as a digital apparatus, generates radio frequency interference and if not installed and used properly in strict accordance with the manufacturer's instructions may cause interference with receiving mediums. This Class A equipment complies with Part 15 of the

FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation. While these rules are designed to provide reasonable protection, there is no guarantee that interference will not occur in a particular installation. You can determine whether interference occurs by monitoring your receiving device while the equipment is connected and a phone call in place.

If problems are experienced:

• Reorient or relocate the receiving TV or radio antenna, where this may be done safely.

To the extent possible, move the telephone system and the radio or television farther away from each other or connect the telephone system and the radio or television to outlets on separate circuits.

• Consult the dealer or an experienced radio/television technician for additional suggestions.

Note

: FCC registration does not constitute an expressed or implied guarantee of performance.

For Devices Intended to be Connected to the Public Switched Telephone Network:

FCC Registration Number

: This telephone equipment complies with Part 68, FCC Rules for connection to the Public Switched Telephone Network (The FCC registration number appears on a label affixed to the

KSU).

Your connection to the telephone line must comply with these FCC Rules:

• Use only an FCC Standard network interface jacks and FCC compliant line cord and plug to connect this equipment to premise wiring.

If a network interface jack is not already installed in your location, you can order one from your telephone company.

Please refer to your Owner’s Manual/User’s Guide for specific installation instructions.

FastRAD Regulations

855601 Book : 855601 FCC Page v Wednesday, October 29, 1997 3:52 PM

v

US Regulations continued

In some states, customers are permitted to install their own jacks.

• The equipment may not be connected to a party line or coin /toll telephone line. Connection to

Party Line Service is subject to state tariffs. (Contact the state public utility commission, public service commission or corporation commission for information).

It is no longer necessary to notify the Telephone Company of your system’s Registration and REN numbers. However, you must provide this information to the telephone company if they request it.

• If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. If advance notice is not practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it necessary.

The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service.

Do not attempt to repair this equipment yourself. If trouble is experienced with this equipment, please refer to the repair and warranty information, noted below. If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved.

Signaling Method

: The equipment allows signaling in DTMF tones. It can complete calls to local and long distance lines and can also complete long distance calls via computer phone systems such as MCI or

SPRINT. This equipment is capable of providing access to interstate providers of operator services through the use of access codes. Modification of this equipment by call aggregators to block access dialing codes is a violation of the Telephone Operator Consumers Act of 1990.

Ringer Equivalence Number

: The FCC Registration information on the product label, includes a Ringer

Equivalence Number (REN) which is used to determine the number of devices you may connect to your phone line. Please refer to the installation instructions with the KSU for more details.

Hearing Aids

: The telephone station sets are compatible with hearing aids equipped with an appropriate telecoil and is compliant with the requirements of the Americans with Disabilities Act (ADA).

Programming Emergency Numbers

: When programming emergency numbers and/or making test calls to emergency numbers:

1.

Remain on the line and briefly explain to the dispatcher the reason for calling before hanging up.

2.

Perform such activities in the off-peak hours, such as early mornings or late evenings.

Substitution of non-approved equipment will void the NORTEL warranty.

Address for warranty and repairs in the US

:

Nortel Networks

640 Massman Drive

Nashville TN 37210

For more information call 1-800-4NORTEL

FastRAD Regulations

855601 Book : 855601 FCC Page vi Wednesday, October 29, 1997 3:52 PM vi

FastRAD Regulations

855601 Book : 855601 Guide Page 1 Wednesday, October 29, 1997 4:06 PM

Introduction

1

The Norstar

Fast Remote Access Device

(FastRAD) allows a personal computer (PC) running

Norstar ICS Remote Tools

(ICSRT) to communicate with a Key Service Unit (KSU). FastRAD also runs with

Companion Diagnostics System

(CDS) and

Companion Manager

. The FastRAD:

• is located on site near either the KSU or the PC

• receives calls from a PC via modem or PC direct connection

• authorizes a PC to access a KSU

• connects a PC with the KSU

• reports KSU alarms to an off-site alarm center

Refer to Figure 1.

FastRAD Installation Guide

855601 Book : 855601 Guide Page 2 Wednesday, October 29, 1997 4:06 PM

2

Teladapt Jack

Norstar

KSU

FastRAD

Distribution

block

At the remote site, the external line is connected to the

FastRAD through a KSU line.

PSTN

The FastRAD and the modem are connected through the telephone network.

ICSRT PC

Figure 1 – System overview of remote connection

Modem

FastRAD Installation Guide

855601 Book : 855601 Guide Page 3 Wednesday, October 29, 1997 4:06 PM

Before you start

3

Make sure you read and follow the instructions in this guide.

Make sure you have the necessary tools to complete the installation. A Special parts check list is provided in this guide.

Make sure all equipment in the FastRAD package is accounted for. A Package check list is provided in this guide.

Make sure the necessary environment and electrical conditions are met. An Environment check list and list of

Electrical requirements are provided in this guide.

Important

: Only one FastRAD can be connected to a KSU.

Environment check list

The FastRAD installation area should be:

❑ clean, free of dust, dry and well ventilated between 0

°

and 50

°

Celsius (32

°

to 122

°

Fahrenheit) non-condensing relative humidity between 5% and 95% within 800 m (2600 feet) of the Norstar KSU

Note

: When using a Norstar 3X8 KSU the FastRAD must be installed within 305 m (1000 feet).

free of Bridge taps on the FastRAD KSU TCM loop free of Loading coils on the FastRAD KSU TCM loop

Package check list

Make sure the package contains:

❑ the Norstar FastRAD an RJ-11 teladapt cord a power supply with a barrel connector a paper template (for mounting)

FastRAD Installation Guide

855601 Book : 855601 Guide Page 4 Wednesday, October 29, 1997 4:06 PM

4

Special check list

To begin an installation you need:

❑ an operating Nortel two-line display telephone for programming the FastRAD a screwdriver two round head, size #8 wood screws, 1 inch long a roll of tape (or four tacks) for mounting the template a list of programming parameters for the FastRAD a unique System identification (ID) number a unique password the software and documentation package

*

Electrical requirements

Make sure the following electrical requirements are met:

❑ line voltage (120 V): 102 - 127 Vac

*

If you are using a PC at the site to test the FastRAD installation, this package is required.

FastRAD Installation Guide

855601 Book : 855601 Guide Page 5 Wednesday, October 29, 1997 4:06 PM

5

Requirements for PC communication

A PC communicates with a FastRAD either through a modem or through an RS-232 cable. A modem is used when the PC is situated at a remote location. An RS-232 cable is used when the

PC is situated near the FastRAD at the customer site.

When you use a PC at the customer site, you must use a 9-pin cable to connect the PC to the RS-232 port on the FastRAD.

This connector is not supplied with the FastRAD. Table 1 shows which pins are used to make a connection with the FastRAD.

Note

: The FastRAD modem supports V.32/V.32bis protocols only. We recommend a baud rate* of 9600 or greater be selected when connecting Norstar PC applications to the

FastRAD remotely using a modem.

*Refers to the PC-Modem DTE speed.

Pin Name

1 DCD

8

9

6

7

4

5

2

3

DSR

RTS

CTS

RI

RXD

TXD

DTR

GND

Function

Data Carrier Detect

Received Data

Transmitted Data

Data Terminal Ready

Ground

Data Set Ready

Request to Send

Clear to Send

Ring Indicator

Table 1 – RS-232 Pin configuration

Direction

from FastRAD from

FastRAD to

FastRAD

to

FastRAD from

FastRAD to

FastRAD from

FastRAD from

FastRAD

FastRAD Installation Guide

855601 Book : 855601 Guide Page 6 Wednesday, October 29, 1997 4:06 PM

6

Connecting the FastRAD

When equipment and environment conditions have been verified, you can begin connecting the FastRAD to the distribution block.

Before you connect the FastRAD, make sure the port works.

Attach a working Norstar two-line display telephone to the port.

If the telephone operates, the port is working.

To connect the FastRAD:

1.

Plug the barrel connector of the power supply into the power connector of the FastRAD and the other end into the wall outlet. See Figure 2.

This unit must be powered from a pluggable

Type A Class 2 power source that is UL and

CSA listed.

2.

Check that the LED on the FastRAD unit is lit to confirm the power connection.

3.

Locate the distribution block.

4.

Mount the RJ-11 teladapt jack next to the distribution block.

5.

Using twisted pair station wire, connect the teladapt jack to a free station port at the distribution block.

Note

: Do not connect the FastRAD to port 101. This port is reserved for the prime set. The FastRAD should be connected to one of the on-core station ports.

FastRAD Installation Guide

855601 Book : 855601 Guide Page 7 Wednesday, October 29, 1997 4:06 PM

7

TCM Port DB-9 Pin

Connector

LED

Barrel Power

Supply Plug

Figure 2 – KSU connection

6.

Connect one end of the RJ-11 teladapt cord to the TCM port on the side panel of the FastRAD. See Figure 2.

7.

Connect the other end to the RJ-11 teladapt jack to the

KSU. Make sure the cord is less than 800 m (2600 feet) long.

Note

: A connection to the FastRAD DB-9 pin serial port is only required for a direct connection to a PC at the site.

FastRAD Installation Guide

855601 Book : 855601 Guide Page 8 Wednesday, October 29, 1997 4:06 PM

8

Mounting the

FastRAD

Before you mount the FastRAD, select a location within 800 m

(2600 feet) of the distribution block that is free of traffic, dust and dampness.

Note

: You do not need to mount the FastRAD on the wall if it is only being used temporarily to program the KSU.

The FastRAD can be mounted either horizontally or vertically.

To mount the FastRAD on the wall:

1.

Attach the paper mounting template to the wall. Make sure the template is even with the wall. See Figure 3.

Note

: This template is found at the center of this guide.

130 mm (5.25 in)

130 mm (5.25 po) 130 mm (5.25 pulg)

PO

Figure 3 – Paper wall mounting template

FastRAD Installation Guide

855601 Book : 855601 Guide Page 9 Wednesday, October 29, 1997 4:06 PM

9

2.

Put the two screws in the wall leaving 10 mm (3/8 in) of each screw exposed. The marks on the template show where the two screws are placed. After the screws are in place, remove the paper template.

Figure 4 – Mounting the FastRAD

3.

Place the two keyhole slots at the back of the FastRAD over the screws and slide the FastRAD onto the screws.

When the FastRAD is securely mounted, you are ready to start programming.

FastRAD Installation Guide

855601 Book : 855601 Guide Page 10 Wednesday, October 29, 1997 4:06 PM

10

Programming the FastRAD

Before you start, make sure you have completed the

FastRAD

Programming Record

found at the end of this guide. This record must include the System ID, Auto-answer line number and Alarm reporting line number.

Table 2 shows the different programming parameters and their default values. If your programming information does not specify a value for one of the fields, assign it to the default value.

Note

: You must program the Required fields for the FastRAD to operate. Also program any Optional fields that apply to your system. Auto-answer should be set to ON if unassisted remote access to the FastRAD is desired.

Programming Field Range

Password

System ID

Auto-answer line number

8 to 10 digits

Up to 10 digits

1 - 999

Alarm reporting line number 1 - 999

Local baud rate

Auto report alarms

300/1200/2400/4800/

9600/19200

ON, OFF

Alarm number 1

Alarm number 2 up to 16 digits up to 16 digits

Retry delay

Number of retries

Alarm reporting baud rate

Alarm reporting parity

Auto-answer

Answer delay

1 - 99 minutes

0 - 9

Low/Medium/High

None/Odd/Even

ON, OFF

6 to 60 seconds

Required / Optional

Required

Default

none

Optional blank

Required for auto-answering Line 001

Required for alarm reporting Line 001

Optional 9600

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

OFF blank blank

15 minutes

5

High

None

OFF

18 seconds

Table 2 – Programming parameters and default values

FastRAD Installation Guide

855601 Book : 855601 Guide Page 11 Wednesday, October 29, 1997 4:06 PM

Starting a programming session

11

The FastRAD cannot be used for remote or direct connections until the user password has been programed through Feature

9**. This initial password programming must occur on-site.

IMPORTANT

: There is no way to recover a lost or forgotten password or return to the default state.

A FastRAD is programmed from a Norstar two-line display telephone that is connected to the KSU. Programming information is entered into the FastRAD using the dialpad on the telephone.

Follow the prompts that appear on the display.

Note

: You cannot start a programming session while you are on a call. When a programming session is in progress, press only the buttons indicated. The programming session is terminated when you press incorrect buttons or when you make or answer a call. Only on a DR2 KSU can you put the programming session on hold to make or answer a call.

If you need to go back a step while you are programming, press

BACK or press

® and start again. If you stop programming for more than three minutes, the display returns to the date and time, and you must restart programming from the beginning.

IMPORTANT

: You must wait 60 seconds before you attempt to program the FastRAD when: the FastRAD is connected or restarted; the power supply is disconnected or the KSU is restarted.

To start a programming session:

1.

Press

ƒ·••

.

The display shows:

Password

EXIT CHNG NEXT

Note

: When the password has been changed, the display shows:

Enter password

. Check the FastRAD installation wiring and start again if the display shows:

Inactive feature

. For more information, refer to

Troubleshooting

, later in this guide.

FastRAD Installation Guide

855601 Book : 855601 Guide Page 12 Wednesday, October 29, 1997 4:06 PM

12

2.

Press

CHNG

to change your programming password.

Using the dialpad, enter your new password. Your password must be from eight to 10 characters long. As you enter your password, the display shows asterisks. The display changes to show:

Confirm password

. When you re-enter your password, asterisks appear on the display.

Note

: We recommend you assign a password the first time you start a programming session. You must assign a password before you can perform remote access. Write down your password, keep it in a safe place and avoid giving it to co-workers. This password can be changed at any time.

3.

Press

OK

to accept your new password. The display changes to show

Password

again.

4.

Press

NEXT

.

The display shows:

RAD Admin

GEN ALARM DATA

The RAD Admin display is the main programming display. This display must appear on the telephone before you can begin to program the FastRAD.

FastRAD Installation Guide

855601 Book : 855601 Guide Page 13 Wednesday, October 29, 1997 4:06 PM

General

Programming

13

General programming allows you to define the System ID number.

Before you begin entering general programming information, make sure the display shows

RAD Admin

. If you do not have this display on the Norstar telephone, follow the steps in

Starting a Programming Session

.

To enter general FastRAD programming information:

1.

Press

GEN

.

The display shows:

System ID number

BACK SHOW NEXT

2.

Press

SHOW

.

The display shows:

-

BACK CHNG NEXT

Note

: If this is a first time installation, we recommend the system ID number must be programmed to allow remote access. If this is not a first time installation, the display shows the last System ID entered.

3.

Press

CHNG

.

The display shows:

-

CLEAR BKSP OK

4.

Using the dialpad, enter the System ID number.

Note

: If you enter a wrong number, press

BKSP to delete the last number entered, or CLEAR to erase all numbers entered.

5.

Press OK to accept the System ID number.

This completes general programming. To continue programming alarm reporting, refer to the next section, Programming

Alarm Reporting.

FastRAD Installation Guide

855601 Book : 855601 Guide Page 14 Wednesday, October 29, 1997 4:06 PM

14

Programming

Alarm

Reporting

The alarm programming session allows you to program the

FastRAD to report alarms to the telephone number of a dedicated alarm center, such as a printer or terminal.

Before you begin an alarm programming session, make sure the display shows RAD Admin.

If you do not have this display on the Norstar telephone, follow the steps listed in Starting a Programming Session.

To program the FastRAD Alarm Reports:

1.

Press ALARM.

The display shows:

Auto-report: OFF

BACK CHNG NEXT

2.

Press CHNG to turn automatic alarm reporting on.

The display shows:

Auto-report: ON

BACK CHNG NEXT

3.

Press NEXT.

The display shows:

Report line: 001

BACK CHNG NEXT

4.

Press CHNG.

The display shows:

Report line:_

CLEAR BKSP OK

5.

Enter the KSU line number the FastRAD uses for remote connections. Refer to the Programming Record for the correct line number.

6.

Press NEXT.

The display shows:

Alarm number 1

BACK SHOW NEXT

7.

Press SHOW to see where the FASTRAD reports its alarms.

The display shows:

<Alarm number>

BACK CHNG NEXT

FastRAD Installation Guide

855601 Book : 855601 Guide Page 15 Wednesday, October 29, 1997 4:06 PM

15

8.

Press CHNG to enter the first alarm report telephone number.

The display shows:

-

CLEAR BKSP OK

9.

Enter the telephone number for Alarm 1.

The display shows:

<alarm number>

CLEAR BKSP OK

10. Press OK.

The display shows:

Alarm number 2

BACK SHOW NEXT

11. Press SHOW.

The display shows:

<Alarm number>

BACK CHNG NEXT

If you do not want to enter a second alarm number, press

NEXT and go to step 14.

12. Press CHNG.

The display shows:

_

CLEAR BKSP OK

13. Enter the telephone number for Alarm 2.

14. Press OK.

The display shows:

Num retries: 5

BACK CHNG NEXT

Note: If you are using the default setting(s), press NEXT and go to step 18.

15. Press CHNG.

The display shows:

Num retries:_

CLEAR BKSP OK

16. Enter the number of retries. This must be a number between 0 and 9.

FastRAD Installation Guide

855601 Book : 855601 Guide Page 16 Wednesday, October 29, 1997 4:06 PM

16

17. Press OK.

The display shows:

Retry mins: 15

BACK CHNG NEXT

18. Press CHNG.

The display shows:

Retry mins:_

CLEAR BKSP OK

19. Enter the number of minutes between retries. This must be a number between 1 and 99.

20. Press OK.

The display shows:

Alarm baud: High

BACK CHNG NEXT

21. To change the baud rate, press CHNG until the desired baud rate appears. The baud rate should match that of the alarm device’s modem. You have three choices: Low, Medium and High. The default is High.

IMPORTANT: Changing the baud rate is not required unless the alarm centre modem is connected to a slow device, such as an old printer. Selecting the Low setting limits the baud rate to less than 300. Selecting the Medium setting limits the baud rate to less than 1200. Selecting the

High setting, the baud rate is determined entirely by the

FastRAD and the alarm centre modems.

22. Press NEXT.

The display shows:

Parity: None

BACK CHNG NEXT

23. To change the parity setting, press CHNG until the desired setting appears. The parity should match that of the alarm device’s modem. You have three choices: None, Odd and

Even. The default is None.

24. Press NEXT.

The display shows:

RAD Admin

GEN ALARM DATA

FastRAD Installation Guide

855601 Book : 855601 Guide Page 17 Wednesday, October 29, 1997 4:06 PM

17

This completes alarm programming. To continue programming

FastRAD call handling, refer to the next section, Programming

Data.

Programming

Data

Data programming allows you to determine how many seconds the FastRAD waits before answering a call on an incoming KSU line. This allows a line to be used normally during business hours and provides Auto-answer capabilities after hours. Autoanswer must be set to ON to allow unassisted access to the

FastRAD.

Before you begin programming, make sure the display shows

RAD Admin.

If you do not have this display on the Norstar telephone, follow the steps in Starting a Programming Session.

To program the FastRAD’s Data:

1.

Press DATA.

The display shows:

Auto-answer: OFF

BACK CHNG NEXT

2.

Press CHNG to turn automatic answer ON.

The display shows:

Auto-answer: ON

BACK CHNG NEXT

3.

Press NEXT.

The display shows:

Answer line: 001

BACK CHNG NEXT

4.

Press CHNG.

The display shows:

Answer line:_

CLEAR BKSP OK

5.

Enter the KSU line number the FastRAD uses for remote connections. Refer to the Programming Record for the correct line number.

FastRAD Installation Guide

855601 Book : 855601 Guide Page 18 Wednesday, October 29, 1997 4:06 PM

18

Note: In general, the following points should be considered while choosing the FastRAD Auto-answer line:

• If possible, use an on-core line for auto-answering.

This allows remote access to the KSU even in the event of an expansion module failure.

• Use a line that is not often used for other purposes, since the FastRAD will auto-answer after a preprogrammed delay.

• Choose only lines that are enabled.

6.

Press OK.

The display shows:

Answer delay: 18

BACK CHNG NEXT

7.

Press CHNG to change the number of seconds the FastRAD waits before answering an incoming data call.

The display shows:

Answer delay:_

CLEAR BKSP OK

8.

Enter the number of seconds you want the FastRAD to wait prior to answering an incoming data call. This number must be between 6 and 60.

Note: The modem “wait for carrier delay” (S Register 7) must be longer than the time it takes for the modem to dial the FastRAD Auto-answer line plus the Answer delay time. For example, if it takes 10 seconds for the modem to dial in to the FastRAD and Answer delay is set to 50 seconds, then the modem “wait for carrier delay” must be greater than 60 seconds.

9.

Press OK.

The display shows:

Local baud: 9600

BACK CHNG NEXT

FastRAD Installation Guide

855601 Book : 855601 Guide Page 19 Wednesday, October 29, 1997 4:06 PM

19

10. Press CHNG until the display shows the desired local serial port baud rate (300, 1200, 2400, 4800, 9600 or 19200).

Note: To use Norstar Manager in a direct connection, the local baud rate must be set to 9600 baud.

11. Press NEXT.

The display shows:

RAD Admin

GEN ALARM DATA

12. Press

® to end programming.

The FastRAD programming is completed. You must now test the FastRAD to make sure it is operating properly.

FastRAD Installation Guide

855601 Book : 855601 Guide Page 20 Wednesday, October 29, 1997 4:06 PM

20

Testing the

FastRAD

After the FastRAD installation and on site programming are completed you should test the FastRAD data transfer capabilities. To test the FastRAD, make a connection between the PC running ICSRT and the KSU at the customer site.

If the PC is not located at the customer site and the FastRAD is not programmed with Auto-answer ON, you must phone the

ICSRT operator and instruct the operator to establish a connection with the FastRAD. In this case, refer to

Rerouting a call to the FastRAD.

If you are using a PC at the work site, refer to ICS Remote Tools

User Guide for instructions about connecting to the RAD.

The test is passed when the remote or local PC establishes a connection with the KSU.

If the FastRAD is programmed to report alarms, you can test alarm calls by disconnecting the FastRAD power supply. After a few seconds, reconnect the power supply. The FastRAD reports an alarm to the specified alarm connection centers.

Rerouting a Call to the FastRAD

If the FastRAD is not set up to Auto-answer a Central Office

(CO) line, ask the ICSRT user to set up an operator assisted-call to your site. If the operator-assisted call is not accepted by the

FastRAD, ensure the FastRAD is not involved in a programming session. Then ask the ICSRT user to attempt another operatorassisted call.

FastRAD Installation Guide

855601 Book : 855601 Guide Page 21 Wednesday, October 29, 1997 4:06 PM

21

Troubleshooting

Troubleshooting the FastRAD installation is needed if you start a programming session and the display shows

Inactive feature.

1.

Check the wiring at the distribution block.

2.

Make sure the Norstar port that the FastRAD is attached to is working.

3.

Check that the power LED on the FastRAD unit is lit to confirm the power connection.

4.

Refer to the appropriate Norstar Installer Guide for further diagnostic tests.

Note: If the wiring at the distribution block has been disconnected, the FastRAD can take up to two minutes to reset after the wiring is reconnected.

After you have checked all the wiring:

1.

Press

ƒ·••.

The display should show:

Enter password

EXIT CHNG NEXT

2.

Press NEXT.

The display shows:

RAD Admin

GEN ALARM DATA

If the display is still showing Inactive feature, repackage the FastRAD, and return it to the point of purchase.

FastRAD Installation Guide

855601 Book : 855601 Guide Page 22 Wednesday, October 29, 1997 4:06 PM

22

Programming

Record

Complete the FastRAD Programming Record before you start programming.

FastRAD Programming Record

Work Site: _______________________________________________________________

Address: ________________________

________________________

________________________

Telephone Number: __________________

Installation Date: __________________

Installer: __________________

Notes: _______________________________________________________________

GENERAL

Enter the System ID number. (Disable Admin if required.) System ID

Number __________

ALARM

Auto- report

Off

On

Report

Line __________

Alarm

Number 1 __________

Choose if you want the FastRAD to report alarms. The default is

Off.

Enter the line number. Enter a number between 001 and 999.

The default is 001.

Enter the telephone number of the device where the FastRAD reports alarms.

Alarm

Number 2 __________

Retry

Delay __________

Number of Retries __________

Alarm

Baud

Parity

Low

Medium

High

None

Odd

Even

DATA

Autoanswer

Answer

Line

Off

On

__________

Enter the telephone number of a second device where the

FastRAD reports alarms.

Enter the number of minutes the FastRAD waits before it retries to report an alarm. Enter a number between 1 and 99.

Enter how many times a FastRAD tries to send an alarm after a failed connection attempt. Enter a number between 0 and 9.

Choose the alarm baud number. The default is High.

Choose which parity setting the FastRAD uses. The default is

None.

Choose if you want the FastRAD to answer incoming calls

(must be ON to allow remote, unassisted access). The default is

Off.

Enter the line number. An on-core KSU line is recommended.

Enter a number between 001 and 999. The default is 001.

FastRAD Installation Guide

855601 Book : 855601 Guide Page 23 Wednesday, October 29, 1997 4:06 PM

23

Answer

Delay

Local

Baud Rate

__________

300

1200

2400

4800

9600

19200

Enter the number of seconds the FastRAD waits before answering a call. Enter a number between 6 to 60. The default is 18.

Choose the baud rate the FastRAD uses for the RS-232 port.

The default is 9600.

FastRAD Installation Guide

855601 Book : 855601 Guide Page 24 Wednesday, October 29, 1997 4:06 PM

24

FastRAD Installation Guide

855601 Cover Back Page 25 Wednesday, November 12, 1997 10:16 AM

1-800-4NORTEL www.nortel.com/norstar

Norstar is a trademark of Nortel Networks .

Printed in Canada

P0855601 Issue 0 5

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Easy to use: The FastRAD has a user-friendly interface that makes it easy to navigate and use.
  • Versatile: The FastRAD can be used to program, test, and troubleshoot a wide variety of telecommunications equipment.
  • Portable: The FastRAD is a portable device that can be easily transported to different locations.
  • Powerful: The FastRAD is a powerful tool that can be used to perform a variety of tasks, including configuration, testing, and troubleshooting.
  • Reliable: The FastRAD is a reliable device that can be used to perform critical tasks with confidence.
  • Accurate: The FastRAD is an accurate device that can be used to obtain precise results.
  • Fast: The FastRAD is a fast device that can be used to perform tasks quickly and efficiently.

Related manuals

Frequently Answers and Questions

What are the requirements for PC communication?
The requirements for PC communication are a PC with a serial port, a null modem cable, and FastRAD software.
How do I connect the FastRAD?
To connect the FastRAD, connect the serial cable from the FastRAD to the serial port on the PC. Then, connect the power supply to the FastRAD.
How do I program the FastRAD?
To program the FastRAD, start a programming session by pressing the 'Prog' button. Then, use the keypad to enter the desired programming commands.