advertisement
Polycom, Inc.
VSX 3000, VSX 5000, and VSX 7000s
(Firmware version: 8.5.0.2)
FIPS 140-2
Non-Proprietary Security Policy
Level 1 Validation
Document Version 1.0
Prepared for: Prepared by:
Polycom, Inc.
4750 Willow Road
Pleasanton, CA 94588-2708
Phone: 1.800.POLYCOM
Fax: (925) 924-6100 http://www.polycom.com
Corsec Security, Inc.
10340 Democracy Lane, Suite 201
Fairfax, VA 22030
Phone: (703) 267-6050
Fax: (703) 267-6810 http://www.corsec.com
© 2007 Polycom, Inc. –
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0
Revision History
Version
1.0
Modification Date
2007-06-15
Modified By
Xiaoyu Ruan
Description of Changes
Release version.
June 15, 2007
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 2 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
Table of Contents
0 INTRODUCTION ...............................................................................................................................................5
0.1
P
URPOSE
.........................................................................................................................................................5
0.2
R
EFERENCES
...................................................................................................................................................5
0.3
D
OCUMENT
O
RGANIZATION
...........................................................................................................................5
1 VSX 3000, VSX 5000, AND VSX 7000S.............................................................................................................6
1.1
O
VERVIEW
......................................................................................................................................................6
1.2
M
ODULE
S
PECIFICATIONS
..............................................................................................................................6
1.3
M
ODULE
I
NTERFACES
....................................................................................................................................8
1.4
R
OLES AND
S
ERVICES
...................................................................................................................................16
1.4.1
Crypto-Officer Role .............................................................................................................................16
1.4.2
User Role .............................................................................................................................................16
1.4.3
Authentication......................................................................................................................................17
1.5
P
HYSICAL
S
ECURITY
....................................................................................................................................17
1.6
O
PERATIONAL
E
NVIRONMENT
......................................................................................................................17
1.7
C
RYPTOGRAPHIC
K
EY
M
ANAGEMENT
..........................................................................................................17
1.7.1
Key Generation ....................................................................................................................................18
1.7.2
Key Input/Output .................................................................................................................................18
1.7.3
Key Storage..........................................................................................................................................19
1.7.4
Key Zeroization....................................................................................................................................19
1.8
S
ELF
-T
ESTS
..................................................................................................................................................19
1.9
D
ESIGN
A
SSURANCE
.....................................................................................................................................19
2 SECURE OPERATION ....................................................................................................................................20
2.1
C
RYPTO
-O
FFICER
G
UIDANCE
.......................................................................................................................20
2.1.1
Initialization.........................................................................................................................................20
2.1.2
Management ........................................................................................................................................20
2.2
U
SER
G
UIDANCE
..........................................................................................................................................21
3 ACRONYMS......................................................................................................................................................23
Table of Figures
F
IGURE
1 VSX 3000.....................................................................................................................................................6
F
IGURE
2 VSX 5000.....................................................................................................................................................7
F
IGURE
3 VSX 7000
S
...................................................................................................................................................7
F
IGURE
4 VSX 7000
E
...................................................................................................................................................7
F
IGURE
5 VSX 8000.....................................................................................................................................................8
F
IGURE
6 VSX 3000 C
ONNECTOR
P
ANEL
....................................................................................................................9
F
IGURE
7 VSX 5000 B
ACK
P
ANEL
.............................................................................................................................10
F
IGURE
8 VSX 7000
E
B
ACK
P
ANEL
...........................................................................................................................12
F
IGURE
9 VSX 7000
S
B
ACK
P
ANEL
...........................................................................................................................13
F
IGURE
10 VSX 8000 B
ACK
P
ANEL
...........................................................................................................................15
Table of Tables
T
ABLE
1 S
ECURITY
L
EVEL
P
ER
FIPS 140-2 S
ECTION
...................................................................................................8
T
ABLE
2 M
APPING OF
FIPS 140-2 L
OGICAL
I
NTERFACES TO
VSX 3000, VSX 5000,
AND
VSX 7000
S
I
NTERFACES
...9
T
ABLE
3 M
APPING OF
FIPS 140-2 L
OGICAL
I
NTERFACES TO
VSX 5000 I
NTERFACES
................................................10
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 3 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
T
ABLE
4 M
APPING OF
FIPS 140-2 L
OGICAL
I
NTERFACES TO
VSX 7000
E
I
NTERFACES
..............................................12
T
ABLE
5 M
APPING OF
FIPS 140-2 L
OGICAL
I
NTERFACES TO
VSX 7000
S
I
NTERFACES
..............................................13
T
ABLE
6 M
APPING OF
FIPS 140-2 L
OGICAL
I
NTERFACES TO
VSX 8000 I
NTERFACES
................................................15
T
ABLE
7 M
APPING OF
C
RYPTO
-O
FFICER
’
S
S
ERVICES TO
I
NPUTS
, O
UTPUTS
, C
RITICAL
S
ECURITY
P
ARAMETERS
(CSP
S
),
AND
A
CCESS
C
ONTROL
...........................................................................................................................16
T
ABLE
8 M
APPING OF
U
SER
’
S
S
ERVICES TO
I
NPUTS
, O
UTPUTS
, CSP
S
,
AND
A
CCESS
C
ONTROL
.................................16
T
ABLE
9 L
IST OF
C
RYPTOGRAPHIC
K
EYS
, C
RYPTOGRAPHIC
K
EY
C
OMPONENTS
,
AND
CSP
S
.....................................17
T
ABLE
10 LED/P
OWER
B
UTTON
L
IGHT
D
ESCRIPTION
...............................................................................................21
T
ABLE
11 BRI N
ETWORK
I
NTERFACE
LED
S
..............................................................................................................22
T
ABLE
12 PRI N
ETWORK
I
NTERFACE
LED
S
..............................................................................................................22
T
ABLE
13 V.35/RS-449/RS-530 N
ETWORK
I
NTERFACE
LED
S
..................................................................................22
T
ABLE
14 A
CRONYMS
................................................................................................................................................23
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 4 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
0 Introduction
0.1 Purpose
This is a non-proprietary Cryptographic Module Security Policy for the VSX 3000, VSX 5000, and VSX 7000s from Polycom, Inc.. This Security Policy describes how the VSX 3000, VSX 5000, and VSX 7000s meet the security requirements of FIPS 140-2 and how to run the module in a secure FIPS 140-2 mode. This policy was prepared as part of the Level 1 FIPS 140-2 validation of the module.
FIPS 140-2 (Federal Information Processing Standards Publication 140-2 – Security Requirements for
Cryptographic Modules) details the U.S. Government requirements for cryptographic modules. More information about the FIPS 140-2 standard and validation program is available on the National Institute of Standards and
Technology (NIST) Cryptographic Module Validation Program (CMVP) website at: http://csrc.nist.gov/cryptval/
The VSX 3000, VSX 5000, and VSX 7000s are referred to in this document as the VSX systems, the hardware modules, the cryptographic modules, or the modules.
0.2 References
This document deals only with operations and capabilities of the module in the technical terms of a FIPS 140-2 cryptographic module security policy. More information is available on the module from the following sources:
•
The Polycom website ( http://polycom.com
) contains information on the full line of products from Polycom.
•
The CMVP website ( http://csrc.nist.gov/cryptval/ ) contains contact information for answers to technical or sales-related questions for the module.
0.3 Document Organization
The Security Policy document is one document in a FIPS 140-2 Submission Package. In addition to this document, the Submission Package contains:
•
Vendor Evidence document
•
Finite State Machine
•
Other supporting documentation as additional references
This Security Policy and the other validation submission documentation were produced by Corsec Security, Inc. under contract to Polycom. With the exception of this Non-Proprietary Security Policy, the FIPS 140-2 Validation
Documentation is proprietary to Polycom and is releasable only under appropriate non-disclosure agreements. For access to these documents, please contact Polycom.
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 5 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
1 VSX 3000, VSX 5000, and VSX 7000s
1.1 Overview
Founded in 1990, Polycom is the only company delivering end-to-end rich media collaborative applications for voice, video, data and the web. Polycom has a wide range of products from desktop and mobile personal systems to room systems to the network core. Polycom’s full range of high-quality voice and video communications endpoints, video management software, web conferencing software, and multipoint conferencing enable organizations of all sizes to increase productivity and agility. Polycom delivers business value by cutting costs, simplifying system management, fostering real time collaboration and decision making, and improving relationships with employees, customers and partners.
The Polycom VSX products are state of the art video-conferencing nodes. These systems provide videoconferencing facilities using all the popular telecommunication protocols such as H.320 H.323, and Session
Initiation Protocol (SIP) and include support of Integrated Services Digital Network (ISDN), Primary rate and Basic rate as well as serial interfaces for V.35, RS-499 and RS-530.
1.2 Module Specifications
The VSX systems feature a variety of models ranging from desktop systems (VSX 3000) to set top appliance systems (VSX 5000, VSX 7000s) to rack mounted systems (VSX 7000e, VSX 8000). All of the models provide top-performance video processing and feature high-performance BSP-15 processors from Equator with 128 MB
SDRAM.
The VSX 3000 is an all-in-one desktop system that includes built-in camera, LCD screen, speakers, and microphone. This model interfaces with an Internet Protocol (IP) network with LAN cable and to ISDN S/T lines with BRI cables, and includes a separate power supply connector. The VSX 3000 is pictured below:
Figure 1 - VSX 3000
The VSX 5000 is an entry-level compact set-top system with built in camera as shown below in Figure 2. The VSX
5000 supports an external microphone for audio input, and can be connected to an IP network with a LAN cable. A monitor either VGA or NTSC/PAL can be connected to the VSX 5000 using the supplied audio/video cables, and a separate power cable connects the device to its power supply.
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 6 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
Figure 2 - VSX 5000
The VSX 7000s is another set-top appliance which provides for a mechanical pan, tilt, zoom camera. The VSX
7000s supports H.323 networks with a internal NIC support 10/100mbps.. The VSX 7000 supports a subwoofer into which the optional Network Interface Card to support ISDN, V.35, RS-499 or RS-530 interfaces. . The VSX 7000s uses an external microphone array and has an internal audio reproduction system. The VSX 7000s is standard with dual video display output support and can support VGA, S-video or composite as the main monitor and the same options for the 2 nd
monitor when the main monitor is not VGA.
Figure 3 - VSX 7000s
The VSX 7000e and VSX 8000 models are rack-mounted systems as depicted in Figure 4 and Figure 5 below. The
VSX 7000e is a video component system designed for medium-sized conferencing rooms, while the VSX 8000 system is a compact component system for custom integrators. These models support connections with monitors the same as the VSX 7000s and third-party cameras through standard S-video interfaces. The VSX 7000e and VSX
8000 models provide connections for external audio input and output, LAN ports, telephone jacks, and power supplies. There is an internal slot in the chassis to support ISDN, V.35, RS-499 or RS-530 interfaces.
Figure 4 - VSX 7000e
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 7 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
Figure 5 - VSX 8000
Per FIPS PUB 140-2, the VSX 3000, VSX 5000, and VSX 7000s are classified as multi-chip standalone cryptographic modules and validated at the following FIPS 140-2 Section levels:
Table 1 - Security Level Per FIPS 140-2 Section
8
9
6
7
10
11
Section
1
Section Title
Cryptographic Module Specification
4
5
2
3
Cryptographic Module Ports and Interfaces
Roles, Services, and Authentication
Finite State Model
Physical Security
Operational Environment
Cryptographic Key Management
EMI/EMC
Self-tests
Design Assurance
Mitigation of Other Attacks
Level
1
1
1
1
1
N/A
1
1
1
1
N/A
1.3 Module Interfaces
The VSX 3000, VSX 5000, and VSX 7000s are multi-chip standalone modules that meet overall level 1 FIPS 140-2 requirements. The cryptographic boundaries of the VSX 3000, VSX 5000, and VSX 7000s are defined by the hard plastic or metal covers that include all the hardware and software components as shown in figures Figure 1 through
Figure 5.
Ports and interfaces on the module can be categorized as the following FIPS 140-2 logical interfaces:
•
Data Input Interface
•
Data Output Interface
•
Control Input interface
•
Status Output Interface
Ports and interfaces of the VSX 3000 system are shown in Figure 6 below. The ports on the module’s connector panel are listed below, and mapped to logical interfaces in Table 2 below.
•
BRI connectors – For ISDN calls
•
Stereo connector – For headphones or desktop speakers
•
Composite video connector – Video input to the system from camera or VCR/DVD
•
Audio connector – Audio input to the system from VCR/DVD
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 8 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
•
LAN connector – For IP calls, VSX Web, and remote management
•
Power connector – For power supply
•
Power switch for the codec – (one of three)
•
VGA connector – For Personal Computer (PC) to use system as a computer monitor and for passing the video image from the VGA input connector to a display device
•
LCD Screen – Screen for video conferencing
•
IR Sensor – Input from IR sensor
•
Speaker – Built-in speaker
•
Camera – Input for video conferencing
•
Microphone – Built-in microphone
•
LED – LEDs indicate system status
Figure 6 - VSX 3000 Connector Panel
The VSX 3000 physical interfaces are located under the system as depicted in Section 2 of the Administrator’s
Guide for the VSX Series, which lists on page one and two the connection cables required for the system. The following table maps VSX 3000 interfaces with FIPS 140-2 logical interfaces:
Table 2 - Mapping of FIPS 140-2 Logical Interfaces to VSX 3000, VSX 5000, and VSX 7000s Interfaces
FIPS 140-2 Logical Interface
Data Input
Data Output
Control Input
Status Output
Power
VSX 3000, VSX 5000, and VSX 7000s Port/Interface
BRI connectors, Composite video connector, LAN connector, VGA connector, Audio
Connector, Microphone, Camera
BRI connectors, Stereo connector, LAN connector, LCD Screen, Speaker
LAN connector, IR Sensor, Power switch
LAN connector, LCD Screen, LEDs
Power connector
The following is the list of ports and interfaces of the VSX 5000 system and Figure 7 below shows the ports on module’s back panel.
•
Power connector – For power supply
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 9 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
•
LAN connector – For IP calls, VSX Web, and remote management
•
Conference link connector – For microphone pod, SoundStation VTX 1000, or Visual Concert VSX
•
VGA connector – VGA connector for input and passes the video image for monitor or projector
•
VCR/DVD inputs – For VCR/DVD to play content into calls
•
Power switch – To power up or down the device
•
Audio connectors – For main monitor audio, or for external speaker system
•
S-Video Connector – S-Video output for monitor
•
Serial port – RS-232 port for RS-232 device
•
IR Sensor – Input from IR sensor
•
Speaker – Built-in speaker
•
Camera – Input for video conferencing
•
LED – LEDs indicate system status
Figure 7 - VSX 5000 Back Panel
Section 1 of the Administrator’s Guide for the VSX Series lists the connection cables required for the system. The
Following table maps VSX 5000 interfaces with FIPS 140-2 logical interfaces.
Table 3 - Mapping of FIPS 140-2 Logical Interfaces to VSX 5000 Interfaces
FIPS 140-2 Logical Interface
Data Input
Data Output
Control Input
Status Output
VSX 3000, VSX 5000, and VSX 7000s Port/Interface
LAN connector, VGA connector, VCR/DVD inputs, Conference link connector, Serial Port, Camera
LAN connector, VGA connector, Audio connectors, S-Video Connector, Serial
Port, Conference link connector, Speaker
Conference link connector, LAN connector, Serial Port, IR Sensor, Power switch
VGA connector, S-Video connector, LAN connector, Serial Port, Conference link connector, LEDs
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 10 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
FIPS 140-2 Logical Interface
Power
VSX 3000, VSX 5000, and VSX 7000s Port/Interface
Power connector
The following is the list of ports and interfaces for the VSX 7000e system and Figure 8 below shows the ports on module’s back panel.
•
Network interface bay – For network interface module (for BRI, PRI, and V.35/RS-449/RS-530 connection)
•
VCR/DVD connector – Play VCR/DVD content into calls or record the calls to VCR/DVD
•
Audio connector – Input to system from ImageShare II and computer, or outputs to external speaker
•
Serial ports – RS-232 port for touch panel, camera control, or other RS-232 devices
•
S-Video connector – Input to system from camera or output for S-Video monitor
•
Analog phone connector – For analog phone line
•
Camera 1 control connector – For camera 1 PTZ control
•
VGA connector – Input to system for ImageShare II and computer VGA, or outputs to VGA monitor and projector
•
LAN connector – For IP calls, VSX Web, and remote management
•
Conference link connector – For microphone pod, SoundStation VTX 1000, or Visual Concert VSX
•
IR Sensor – Input from IR sensor
•
Power button – Controls power and provides system status
•
LED – LEDs indicate system status
•
Power connector – For power cord
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 11 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
Figure 8 - VSX 7000e Back Panel
Section 1 of the Administrator’s Guide for the VSX Series lists the connection cables required for the VSX 7000e system. The following table maps VSX 7000e interfaces with FIPS 140-2 logical interfaces.
Table 4 - Mapping of FIPS 140-2 Logical Interfaces to VSX 7000e Interfaces
FIPS 140-2 Logical Interface
Data Input
Data Output
Control Input
Status Output
Power
VSX 3000, VSX 5000, and VSX 7000se Port/Interface
Network interface bay, VCR/DVD connector, Audio connector, Serial ports, S-Video connector, Analog phone connector, VGA connector, LAN connector, Conference link connector
Network interface bay, VCR/DVD connector, Audio connector, Serial ports, S-Video connector, Analog phone connector, VGA connector, LAN connector, Conference link connector
Network interface bay, Serial ports, Camera 1 control connector, LAN connector,
Conference link connector, IR Sensor, Power button
Network interface bay, Serial ports, LAN connector, Conference link connector, Power button, LEDs
Power connector
The following list provides the ports and interfaces of the VSX 7000s system and Figure 9 below shows the ports on module’s back panel.
•
Power connector – Houses power for subwoofer and optional network interface module (for BRI, PRI, and
V.35/RS-449/RS-530 connection)
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 12 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
•
LAN connector – For IP calls, VSX Web, and remote management
•
Conference link connector – For microphone pod, SoundStation VTX 1000, or Visual concert VSX
•
VGA connector – Output from system for VGA monitor or projector
•
VCR/DVD connector – Play VCR/DVD connect into calls or record call content
•
Power switch
•
S-Video connector – Input from camera or output to S-Video monitor
•
Audio connector – Output from system for external speaker system
•
Serial RS-232 port – RS-232 port for touch panel, camera control, or other RS-232 device
•
IR Sensor – Input from IR sensor
•
Speaker – Built-in speaker
•
Camera – Input for video conferencing
•
LED – LEDs indicate system status
Figure 9 - VSX 7000s Back Panel
Section 1 of the Administrator’s Guide for the VSX Series lists the connection cables required for the system. The following table maps VSX 7000s interfaces with FIPS 140-2 logical interfaces.
Table 5 - Mapping of FIPS 140-2 Logical Interfaces to VSX 7000s Interfaces
FIPS 140-2 Logical Interface
Data Input
Data Output
Control Input
Status Output
Power
VSX 3000, VSX 5000, and VSX 7000ss Port/Interface
LAN connector, Conference link connector, VCR/DVD connector, Serial port, S-Video connector, Camera
LAN connector, VGA connector, VCR/DVD connector, S-Video connector, Audio connector, Serial port, Conference link connector, Speaker
LAN connector, Serial port, Conference link connector, IR Sensor, Power switch
LAN connector, VGA connector, Serial port, Conference link connector, LEDs
Power connector
The following is the list of ports and interfaces of the VSX 8000 system and Figure 10 below shows the ports on module’s connector panel.
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 13 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
•
Network interface bay – For network interface module (for BRI, PRI, and V.35/RS-449/RS-530 connection)
•
Balanced Audio connector – Input for mixed or powerful microphones or output for external audio equipment
•
VCR/DVD connector – Play VCR/DVD content into calls or record the calls to VCR/DVD
•
Serial ports – RS-232 port for touch panel, camera control, or other RS-232 device
•
Monitor 1Y and C – output for main monitor
•
S-Video connector – Input to system from camera or output for S-Video monitor
•
Audio connector –Output to external speaker
•
VGA connector – Input to system for ImageShare II and computer VGA, or outputs to VGA monitor and projector
•
LAN connector – For IP calls, VSX Web, and remote management
•
Conference link connector – For microphone pod, SoundStation VTX 1000, or Visual Concert VSX
•
IR Sensor – Input from external IR sensor
•
Analog phone connector – For analog phone line
•
Camera 1 control connector – For camera 1 PTZ control
•
Camera 1Y and C – Input from main camera
•
IR Sensor – Input from IR sensor
•
Power button – Controls power and provides system status
•
LED – LEDs indicate system status
•
Power connector – For power cord
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 14 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
Figure 10 - VSX 8000 Back Panel
Section 1 of the Administrator’s Guide for the VSX Series lists the connection cables required for the system. The following table maps VSX 8000 interfaces with FIPS 140-2 logical interfaces.
Table 6 - Mapping of FIPS 140-2 Logical Interfaces to VSX 8000 Interfaces
FIPS 140-2 Logical Interface
Data Input
Data Output
Control Input
Status Output
Power
VSX 3000, VSX 5000, and VSX 7000s Port/Interface
Network interface bay, Balanaced Audio connector, VCR/DVD connector, Serial port, S-Video connector, VGA connector, LAN connector, Conference link connector, Analog phone connector, Camera 1Y and C
Network interface bay, Balanaced Audio connector, VCR/DVD connector, Serial port, Monitor
1Y and C, S-Video connector, Audio connector, VGA connector, LAN connector, Analog phone connector, Conference link connector
Serial port, LAN connector, IR Sensor, Camera 1 control connector, Conference link connector, IR Sensor, Power switch
Serial port, LAN connector, Conference link connector, Power button, LEDs
Power connector
Please see User Guidance section of this document for list LEDs and description of their behavior.
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 15 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
1.4 Roles and Services
The modules support two authorized roles (as required by FIPS 140-2) that operators may assume: a Crypto Officer role and User role.
1.4.1 Crypto-Officer Role
The Crypto-Officer (CO) installs and uninstalls the cryptographic module. Also, the CO is responsible for monitoring and configuring the modules and call settings.
The Crypto-Officer can manage the VSX modules over a Transport Layer Security (TLS) v1 session through a web interface. Through this interface, the Crypto-Officer is able to configure the device and setup a call, change secure mode of operation, monitor current status and perform virtually all of the management of the module. Configuration of the modules and viewing of status can be performed with a Command Line Interface (CLI) over the local serial port or remotely via Telnet over TLS. All the management and configuration capabilities are available via the
VSX’s web interface are also available via secure telnet over TLS. The telnet interface includes additional debug commands that are not available over the web. The Crypto-Officer has access to the following services:
Table 7 - Mapping of Crypto-Officer’s Services to Inputs, Outputs, Critical Security Parameters (CSPs), and Access
Control
Service
Install
Description
Assemble the systems and setup network configurations
Uninstall
Run Self-Test
Room monitoring
Remote diagnostics
Call Detail Reports
Disassemble the VSX system
Perform the self-test on demand
Monitor meeting rooms in or out of a call using the Web
Director feature in
VSX Web.
Identify and correct issues that affect the user’s experience via
VSX Web interface.
Access the system’s call history using local or remote management interface.
System configuration Run the system setup wizard locally or remotely to get the system up and running.
Input
Command
Command
Command
Command
Command
Command
Command
Output
Result of installation
Uninstalled module
Status output
Status output
Status output
Modules’ settings and status output
Modules’ settings and status output
CSP and Access Control
None
None
None x.509 certificate – Read
Session key –Read/Write
CO password – Read x.509 certificate – Read
Session key –Read/Write
CO password – Read x.509 certificate – Read
Session key –Read/Write
CO password – Read x.509 certificate – Read
Session key –Read/Write
CO password – Read
1.4.2 User Role
Users access teleconferencing services via the LAN port (for IP calls) or the Network Interface Bay port (ISDN calls). Services provided for Users are given below in Table 8.
Table 8 - Mapping of User’s Services to Inputs, Outputs, CSPs, and Access Control
Service Description Input Output CSP and Access
Control
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 16 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
Service
Secured call on IP network
Description
Placing secured call on
IP network via LAN port
Secured call on ISDN Placing secured call on
ISDN via BRI/PRI port
Input
Command and calling information
Command and calling information
Output CSP and Access
Control
Connection established Diffie-Hellman key pairs – Read
IP Encryption Key –
Read/Write
Connection established Diffie-Hellman key pairs – Read
ISDN Encryption Key
– Read/Write
1.4.3 Authentication
The modules were not tested for role-based or identity-based authentication requirement as level 1 modules.
However, the modules authenticate Crypto-Officer with x.509 certificate during TLS handshake. The users do not authenticate themselves to the module.
1.5 Physical Security
The VSX 3000, VSX 5000, and VSX 7000s are multi-chip standalone cryptographic modules. The modules’ hardware is composed of production-grade components and the modules are entirely enclosed in solid metal cases.
These cases enclose all of the modules’ internal components and serve as the cryptographic boundaries for the modules.
The VSX systems were tested and found conformant to the Electromagnetic Interference/Electromagnetic
Compatibility (EMI/EMC) requirements specified by 47 Code of Federal Regulations, Part 15, Subpart B,
Unintentional Radiators, Digital Devices, Class A (i.e., for business use).
1.6 Operational Environment
The operational environment requirements do not apply to the VSX 3000, VSX 5000, and VSX 7000s. The modules do not provide a general purpose Operating System (OS) and only allow the updating of image components after checking a Digital Signature Algorithm (DSA) signature on new software images.
1.7 Cryptographic Key Management
The VSX modules implement the following FIPS-approved algorithms:
•
AES (CBC, OFB) - key sizes 128, 192, 256 (Cert #431)
•
FIPS 186-2 Appendix 3.1 PRNG (Cert #224)
•
Secure Hashing Algorithm (SHA-1) – Byte oriented (Cert #501)
•
TDES (CBC) 1, 2, 3 keying options (Cert #460)
•
DSA (verify) 1024 bits (Cert #178)
Additionally, the module utilizes the following non-FIPS-approved algorithm implementation:
•
Diffie-Hellman (key agreement, key establishment methodology provides 80-bits of encryption strength)
•
RSA (key wrapping, key establishment methodology provides 80-bits of encryption strength)
•
Hardware Random Number Generator (RNG) – for seeding the FIPS-approved deterministic RNG
The module supports the following critical security parameters:
Table 9 - List of Cryptographic Keys, Cryptographic Key Components, and CSPs
Key Key Type Generation /
Input
Output Storage Zeroization Use
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 17 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
Key
x.509 certificate
(RSA Public key)
Key Type
1024 bits RSA public key
RSA Private key 1024 bits RSA private key
Diffie-Hellman public key
Diffie-Hellman private key
Integrity Check
Key
Session Key
1024 bits public key
1024 bits private key
Generation /
Input
Generated externally, input in plaintext
Generated externally, input in plaintext
Generated internally
Generated internally
1024 bits DSA
Public key
Generated externally, inputted in plaintext
192 bits TDES
CBC key
Generated internally during
TLS handshake
IP Encryption
Key
ISDN
Encryption Key
PRNG seed
128 bits AES
CBC key
Generated internally during
Diffie-Hellman key agreement
128, 192, 256 bits AES OFB keys
Generated internally during
Diffie-Hellman key agreement
20 bytes of seed value
Internally generated
Output
Output in plaintext
Output in plaintext
Never exits the module
Never exits the module
Never exits the module
Never exits the module
Storage
Stored in volatile memory
Stored in volatile memory
Stored in Flash in plaintext
Held in volatile memory in plaintext.
Held in volatile memory in plaintext.
Zeroization
Stored in Flash in plaintext
Erasing the flash image
Never exits the module
Stored in Flash in plaintext
Erasing the flash image
Zerorized on reboot.
Zerorized on reboot.
Erasing the flash image
Exits in encrypted form
(RSA key transport)
Held in volatile memory in plaintext.
Zerorized on reboot.
Zerorized on reboot.
Zerorized on reboot.
Never exits the module
Held in volatile memory only in plaintext.
Zerorized on reboot
Use
Authenticates the module during
TLS handshake
Authenticates the module during
TLS handshake
Establishes a session key (IP or
ISDN Encryption
Key) during
H.323 negotiation
Establishes a session key (IP or
ISDN Encryption
Key) during
H.323 negotiation
Checks integrity of the software at power-up of the module
Encrypts TLS traffic
Encrypts IP calls
Encrypts ISDN calls
Produce FIPS approved random number
1.7.1 Key Generation
The modules generate symmetric keys and FIPS-approved PRNG seeds internally. The symmetric keys (Session
Key, IP Encryption Key, and ISDN Encryption Key) and Diffie-Hellman key pair are generated using a FIPSapproved 186-2 Appendix 3.1 algorithm. Twenty bytes of hardware generated noise is used to create a PRNG seed, and RSA key pair is generated externally and input into the module in plaintext.
1.7.2 Key Input/Output
Rivest, Shamir, Adleman (RSA) key pair is generated externally and input to the modules in plaintext. The RSA private key and DH private key never exit the module, while the public keys are output in plaintext. The Session key exits the module in encrypted form during TLS handshakes (protected within RSA key transport). The IP Encryption
Key and ISDN Encryption Key are never output from the module. Other CSPs and keys, such as the Integrity Check
Key and PRNG seed are never output from the modules.
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 18 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
1.7.3 Key Storage
The RSA public/private key pair and Integrity Check Key are stored in the modules’ flash drives in plaintext form.
The Session Key, IP Encryption Key, ISDN Encryption Key, DH public/private key pair, and PRNG seed are held in volatile memory in plaintext.
1.7.4 Key Zeroization
The RSA key pair is zeroized by overwriting the flash image. The Session Key, IP Encryption Key, ISDN
Encryption Key, Diffie-Hellman (DH) private/public key pair and PRNG seed are available only temporarily in volatile memory during video calls. These ephemeral keys and CSP are zeroized after the session is closed or whenever power is cycled.
1.8 Self-Tests
The VSX 3000, VSX 5000, and VSX 7000s perform the following self-tests at power-up:
•
Software integrity check using a DSA signature verification
•
Known Answer Tests (KATs) o
AES Known Answer Test (KAT) o
Triple-DES KAT o
RSA pairwise consistency check o FIPS 186-2 Appendix 3.1 PRNG KAT
The cryptographic modules also perform the following conditional self-tests:
•
Continuous RNG for FIPS 186-2 PRNG
•
Continuous RNG for non-approved RNG for entropy gathering
If any of the power-up self-test fails, the modules log the failure, and notification is provided to Crypto Officers through serial traces. Security relevant module functionality is not provided until all self-tests are passed.
In case a self-test fails, the logged trace indicates which self-test failed, and the modules display a warning message indicating the required reboot for the system. Since these messages are not available through the Secure Telnet interface before all self-tests have passed, the messages are echoed to any connected monitor screen.
1.9 Design Assurance
Polycom uses automated Configuration Management (CM) of their source code modules, organizing source code into separate version-controlled depots. Polycom uses Accurev’s TimeSafe® Configuration Management System to perform automated source code control. Additionally, Microsoft Visual Source Safe (VSS) version 6.0 is used to provide configuration management for the module’s FIPS documentation. This CM software and Polycom’s process provides access control, versioning, and logging for all module source code and documentation.
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 19 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
2 Secure Operation
The VSX 3000, VSX 5000, and VSX 7000s meet Level 1 requirements for FIPS 140-2. The sections below describe how to place and keep the module in FIPS-approved mode of operation.
2.1 Crypto-Officer Guidance
The Crypto-Officer is responsible for initialization and security-relevant configuration and management of the module through the web management interface, serial port from a non networked PC, or secure Telnet over TLS.
Please see Polycom’s Administrator’s Guide for the VSX Series for more information on setting up, configuring and maintaining the modules.
2.1.1 Initialization
The Crypto-Officer is responsible for putting the modules in FIPS mode of Operation, by enabling the system to automatically encrypt calls. AES encryption is a standard feature on all VSX systems. The system will be shipped by default in Non-Secure Mode. To put the modules in FIPS mode of Operation, the Crypto-Officer must: o
Go to System
→
Admin Settings
→
System Security
o
Select Secure Mode o
Selecting the Secure mode will result in a system reset o
The change of mode from Non-Secure mode to secure mode shall initiate Crypto-Officer password change request
2.1.2 Management
Following are the points of System behavior in FIPS mode of Operation: o Default password (System Serial number) or Dummy password (No password), is not allowed for
'admin' login in the secured mode. o
Only https over TLS, secure telnet, and secure FTP connections are allowed in the secured mode. The standard http connections with no security will not be allowed. o Media encryption during a call (H.323/H.320) will always be set to ON (AES-Encryption ON)
The following table details the port number to be used for secure applications, telnet, FTP, and https over TLS.
Application
TLS Telnet Debug Port
TLS Telnet API Port
TLS FTP for control Connection
TLS FTP for data Connection
TLS http
Port Number
992
993
990
989
443
The Crypto-Officer is able to monitor and configure the module via the web interface (https over TLS), serial port, or via secure telnet (Telnet over TLS). Detailed instructions to monitor and troubleshoot the systems are provided in the Administrator’s Guide for the VSX Series.
Software upgrade is not allowed in FIPS mode of Operation.
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 20 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
2.2 User Guidance
The User does not have the ability to configure sensitive information on the module. They only access the secured communication functionality of the module. Users can find the basic instructions to use the VSX systems in Getting
Started Guide for the VSX Series.
Users are responsible for determining when to place encrypted video calls, determining when they wish to verify encryption keys with the other side on a video call, and whether they wish to hang up a video call if encryption cannot be setup or keys verified. Users may not place unencrypted calls in FIPS mode of operation.
The module has several LEDs that help users to understand systems’ general status. The modules have a dedicated
LED at front or transparent power button light to indicate system status. Description of the LED status is described in the Table 10 below.
Table 10 - LED/Power Button Light Description
Model
VSX 3000 (LED)
VSX 5000 (LED)
VSX 7000e (Power Button)
VSX 7000s (LED)
VSX 7000e (Power Button)
VSX 8000 (Power Button)
Description
Indicators are off
Green indicator blinks slowly
Green indicator flashes when you use the remote control
Amber indicator flashes when you use the remote control
Green indicator is on
Amber indicator is on The system is in a call.
VSX 3000: Red indicator is on
VSX 5000, VSX 7000s: Mute indicator on the Polycom microphone is red
Blue indicator is on
Green indicator is on
Green indicator blinks
Red indicator turns on momentarily
Mute indicator on the Polycom microphone is red
Modules’ Status
No power to the system.
The system is sleeping.
The system is not in a call, and is receiving signals from the remote control.
The system is in a call, and is receiving signals from the remote control.
The system is ready to make a call.
Amber indicator is on The system is in a call.
The system microphone is muted.
The system is connected to power but powered off.
The system is powered on.
The remote control has been picked up or set down.
The system is powering off.
The system microphone is muted.
On VSX 5000, VSX 7000e, VSX 7000s, and VSX 8000 systems, the BRI network interface lights are located on the network interface module. On the VSX 3000 system, the lights are located on the back of the system near the BRI connectors.
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 21 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0 June 15, 2007
Table 11 - BRI Network Interface LEDs
LED Status Status Description
Indicators are off
Green indicator is on
•
No power to the system, or
•
The system is not connected to the network, or
•
The system is not receiving a clock signal from the network, or
•
The system is restarting
•
The system is receiving a clock signal from the network.
Yellow indicator is on
•
The system is able to make a call.
Green and yellow indicators are on
•
The system is receiving a software update, or
•
The system is operating normally.
The PRI network interface is available for VSX 7000e, VSX 7000s, and VSX 8000 systems.
Table 12 - PRI Network Interface LEDs
LED Status
Indicators are off
Red indicator is on or blinking
Status Description
No power to the system.
The system is not connected to the ISDN network, or there is a problem with the ISDN line.
Yellow indicator is on or blinking There is a problem with the ISDN line.
Green indicator is on The system is able to make and receive calls.
The serial V.35/RS-449/RS-530 network interface is available for VSX 7000e, VSX 7000s, and VSX 8000 systems.
Table 13 - V.35/RS-449/RS-530 Network Interface LEDs
LED Status
Indicators are off
Yellow indicator is on
Yellow and green indicators are on The system is in a call.
Status Description
•
No power to the system, or
•
The system is not communicating with the network, or
•
The system is restarting.
The system is receiving a clock signal from the network (able to make a call).
Yellow and green indicators are on The system is in a call.
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 22 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
Non-Proprietary Security Policy, Version 1.0
3 Acronyms
Table 14 - Acronyms
Acronym
API
Definition
Application Programming Interface
BRI
CLI
Basic Rate Interface
Command Line Interface
CM Configuration Management
CMVP Cryptographic Module Validation Program
CSP
DH
Critical Security Parameter
Diffie-Hellman
DSA Digital Signature Algorithm
EMC Electromagnetic Compatibility
EMI Electromagnetic Interference
FIPS Federal Information Processing Standard
IP Internet Protocol
ISDN Integrated Services Digital Network
KAT Known Answer Test
NIST National Institute of Standards and Technology
OS
PC
Operating System
Personal Computer
PRI ISDN Primary Rate Interface
RNG Random Number Generator
RSA
SHA
Rivest Shamir and Adleman
Secure Hash Algorithm
TLS Transport Layer Security
VSS Visual Source Safe
June 15, 2007
Polycom VSX 3000, VSX 5000, and VSX 7000s Page 23 of 23
© 2007 Polycom, Inc. -
This document may be freely reproduced and distributed whole and intact including this Copyright Notice.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 5 INTRODUCTION
- 6 VSX 3000, VSX 5000, AND VSX 7000S
- 16 Crypto-Officer Role
- 16 User Role
- 17 Authentication
- 18 Key Generation
- 18 Key Input/Output
- 19 Key Storage
- 19 Key Zeroization
- 20 SECURE OPERATION
- 20 Initialization
- 20 Management
- 23 ACRONYMS