Polycom VSX 5000 Digital Camera User Manual


Add to my manuals
23 Pages

advertisement

Polycom VSX 5000 Digital Camera User Manual | Manualzz

Polycom, Inc.

VSX 3000, VSX 5000, and VSX 7000s

(Firmware version: 8.5.0.2)

FIPS 140-2

Non-Proprietary Security Policy

Level 1 Validation

Document Version 1.0

Prepared for: Prepared by:

Polycom, Inc.

4750 Willow Road

Pleasanton, CA 94588-2708

Phone: 1.800.POLYCOM

Fax: (925) 924-6100 http://www.polycom.com

Corsec Security, Inc.

10340 Democracy Lane, Suite 201

Fairfax, VA 22030

Phone: (703) 267-6050

Fax: (703) 267-6810 http://www.corsec.com

© 2007 Polycom, Inc. –

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0

Revision History

Version

1.0

Modification Date

2007-06-15

Modified By

Xiaoyu Ruan

Description of Changes

Release version.

June 15, 2007

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 2 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

Table of Contents

0 INTRODUCTION ...............................................................................................................................................5

0.1

P

URPOSE

.........................................................................................................................................................5

0.2

R

EFERENCES

...................................................................................................................................................5

0.3

D

OCUMENT

O

RGANIZATION

...........................................................................................................................5

1 VSX 3000, VSX 5000, AND VSX 7000S.............................................................................................................6

1.1

O

VERVIEW

......................................................................................................................................................6

1.2

M

ODULE

S

PECIFICATIONS

..............................................................................................................................6

1.3

M

ODULE

I

NTERFACES

....................................................................................................................................8

1.4

R

OLES AND

S

ERVICES

...................................................................................................................................16

1.4.1

Crypto-Officer Role .............................................................................................................................16

1.4.2

User Role .............................................................................................................................................16

1.4.3

Authentication......................................................................................................................................17

1.5

P

HYSICAL

S

ECURITY

....................................................................................................................................17

1.6

O

PERATIONAL

E

NVIRONMENT

......................................................................................................................17

1.7

C

RYPTOGRAPHIC

K

EY

M

ANAGEMENT

..........................................................................................................17

1.7.1

Key Generation ....................................................................................................................................18

1.7.2

Key Input/Output .................................................................................................................................18

1.7.3

Key Storage..........................................................................................................................................19

1.7.4

Key Zeroization....................................................................................................................................19

1.8

S

ELF

-T

ESTS

..................................................................................................................................................19

1.9

D

ESIGN

A

SSURANCE

.....................................................................................................................................19

2 SECURE OPERATION ....................................................................................................................................20

2.1

C

RYPTO

-O

FFICER

G

UIDANCE

.......................................................................................................................20

2.1.1

Initialization.........................................................................................................................................20

2.1.2

Management ........................................................................................................................................20

2.2

U

SER

G

UIDANCE

..........................................................................................................................................21

3 ACRONYMS......................................................................................................................................................23

Table of Figures

F

IGURE

1 VSX 3000.....................................................................................................................................................6

F

IGURE

2 VSX 5000.....................................................................................................................................................7

F

IGURE

3 VSX 7000

S

...................................................................................................................................................7

F

IGURE

4 VSX 7000

E

...................................................................................................................................................7

F

IGURE

5 VSX 8000.....................................................................................................................................................8

F

IGURE

6 VSX 3000 C

ONNECTOR

P

ANEL

....................................................................................................................9

F

IGURE

7 VSX 5000 B

ACK

P

ANEL

.............................................................................................................................10

F

IGURE

8 VSX 7000

E

B

ACK

P

ANEL

...........................................................................................................................12

F

IGURE

9 VSX 7000

S

B

ACK

P

ANEL

...........................................................................................................................13

F

IGURE

10 VSX 8000 B

ACK

P

ANEL

...........................................................................................................................15

Table of Tables

T

ABLE

1 S

ECURITY

L

EVEL

P

ER

FIPS 140-2 S

ECTION

...................................................................................................8

T

ABLE

2 M

APPING OF

FIPS 140-2 L

OGICAL

I

NTERFACES TO

VSX 3000, VSX 5000,

AND

VSX 7000

S

I

NTERFACES

...9

T

ABLE

3 M

APPING OF

FIPS 140-2 L

OGICAL

I

NTERFACES TO

VSX 5000 I

NTERFACES

................................................10

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 3 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

T

ABLE

4 M

APPING OF

FIPS 140-2 L

OGICAL

I

NTERFACES TO

VSX 7000

E

I

NTERFACES

..............................................12

T

ABLE

5 M

APPING OF

FIPS 140-2 L

OGICAL

I

NTERFACES TO

VSX 7000

S

I

NTERFACES

..............................................13

T

ABLE

6 M

APPING OF

FIPS 140-2 L

OGICAL

I

NTERFACES TO

VSX 8000 I

NTERFACES

................................................15

T

ABLE

7 M

APPING OF

C

RYPTO

-O

FFICER

S

S

ERVICES TO

I

NPUTS

, O

UTPUTS

, C

RITICAL

S

ECURITY

P

ARAMETERS

(CSP

S

),

AND

A

CCESS

C

ONTROL

...........................................................................................................................16

T

ABLE

8 M

APPING OF

U

SER

S

S

ERVICES TO

I

NPUTS

, O

UTPUTS

, CSP

S

,

AND

A

CCESS

C

ONTROL

.................................16

T

ABLE

9 L

IST OF

C

RYPTOGRAPHIC

K

EYS

, C

RYPTOGRAPHIC

K

EY

C

OMPONENTS

,

AND

CSP

S

.....................................17

T

ABLE

10 LED/P

OWER

B

UTTON

L

IGHT

D

ESCRIPTION

...............................................................................................21

T

ABLE

11 BRI N

ETWORK

I

NTERFACE

LED

S

..............................................................................................................22

T

ABLE

12 PRI N

ETWORK

I

NTERFACE

LED

S

..............................................................................................................22

T

ABLE

13 V.35/RS-449/RS-530 N

ETWORK

I

NTERFACE

LED

S

..................................................................................22

T

ABLE

14 A

CRONYMS

................................................................................................................................................23

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 4 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

0 Introduction

0.1 Purpose

This is a non-proprietary Cryptographic Module Security Policy for the VSX 3000, VSX 5000, and VSX 7000s from Polycom, Inc.. This Security Policy describes how the VSX 3000, VSX 5000, and VSX 7000s meet the security requirements of FIPS 140-2 and how to run the module in a secure FIPS 140-2 mode. This policy was prepared as part of the Level 1 FIPS 140-2 validation of the module.

FIPS 140-2 (Federal Information Processing Standards Publication 140-2 – Security Requirements for

Cryptographic Modules) details the U.S. Government requirements for cryptographic modules. More information about the FIPS 140-2 standard and validation program is available on the National Institute of Standards and

Technology (NIST) Cryptographic Module Validation Program (CMVP) website at: http://csrc.nist.gov/cryptval/

The VSX 3000, VSX 5000, and VSX 7000s are referred to in this document as the VSX systems, the hardware modules, the cryptographic modules, or the modules.

0.2 References

This document deals only with operations and capabilities of the module in the technical terms of a FIPS 140-2 cryptographic module security policy. More information is available on the module from the following sources:

The Polycom website ( http://polycom.com

) contains information on the full line of products from Polycom.

The CMVP website ( http://csrc.nist.gov/cryptval/ ) contains contact information for answers to technical or sales-related questions for the module.

0.3 Document Organization

The Security Policy document is one document in a FIPS 140-2 Submission Package. In addition to this document, the Submission Package contains:

Vendor Evidence document

Finite State Machine

Other supporting documentation as additional references

This Security Policy and the other validation submission documentation were produced by Corsec Security, Inc. under contract to Polycom. With the exception of this Non-Proprietary Security Policy, the FIPS 140-2 Validation

Documentation is proprietary to Polycom and is releasable only under appropriate non-disclosure agreements. For access to these documents, please contact Polycom.

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 5 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

1 VSX 3000, VSX 5000, and VSX 7000s

1.1 Overview

Founded in 1990, Polycom is the only company delivering end-to-end rich media collaborative applications for voice, video, data and the web. Polycom has a wide range of products from desktop and mobile personal systems to room systems to the network core. Polycom’s full range of high-quality voice and video communications endpoints, video management software, web conferencing software, and multipoint conferencing enable organizations of all sizes to increase productivity and agility. Polycom delivers business value by cutting costs, simplifying system management, fostering real time collaboration and decision making, and improving relationships with employees, customers and partners.

The Polycom VSX products are state of the art video-conferencing nodes. These systems provide videoconferencing facilities using all the popular telecommunication protocols such as H.320 H.323, and Session

Initiation Protocol (SIP) and include support of Integrated Services Digital Network (ISDN), Primary rate and Basic rate as well as serial interfaces for V.35, RS-499 and RS-530.

1.2 Module Specifications

The VSX systems feature a variety of models ranging from desktop systems (VSX 3000) to set top appliance systems (VSX 5000, VSX 7000s) to rack mounted systems (VSX 7000e, VSX 8000). All of the models provide top-performance video processing and feature high-performance BSP-15 processors from Equator with 128 MB

SDRAM.

The VSX 3000 is an all-in-one desktop system that includes built-in camera, LCD screen, speakers, and microphone. This model interfaces with an Internet Protocol (IP) network with LAN cable and to ISDN S/T lines with BRI cables, and includes a separate power supply connector. The VSX 3000 is pictured below:

Figure 1 - VSX 3000

The VSX 5000 is an entry-level compact set-top system with built in camera as shown below in Figure 2. The VSX

5000 supports an external microphone for audio input, and can be connected to an IP network with a LAN cable. A monitor either VGA or NTSC/PAL can be connected to the VSX 5000 using the supplied audio/video cables, and a separate power cable connects the device to its power supply.

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 6 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

Figure 2 - VSX 5000

The VSX 7000s is another set-top appliance which provides for a mechanical pan, tilt, zoom camera. The VSX

7000s supports H.323 networks with a internal NIC support 10/100mbps.. The VSX 7000 supports a subwoofer into which the optional Network Interface Card to support ISDN, V.35, RS-499 or RS-530 interfaces. . The VSX 7000s uses an external microphone array and has an internal audio reproduction system. The VSX 7000s is standard with dual video display output support and can support VGA, S-video or composite as the main monitor and the same options for the 2 nd

monitor when the main monitor is not VGA.

Figure 3 - VSX 7000s

The VSX 7000e and VSX 8000 models are rack-mounted systems as depicted in Figure 4 and Figure 5 below. The

VSX 7000e is a video component system designed for medium-sized conferencing rooms, while the VSX 8000 system is a compact component system for custom integrators. These models support connections with monitors the same as the VSX 7000s and third-party cameras through standard S-video interfaces. The VSX 7000e and VSX

8000 models provide connections for external audio input and output, LAN ports, telephone jacks, and power supplies. There is an internal slot in the chassis to support ISDN, V.35, RS-499 or RS-530 interfaces.

Figure 4 - VSX 7000e

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 7 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

Figure 5 - VSX 8000

Per FIPS PUB 140-2, the VSX 3000, VSX 5000, and VSX 7000s are classified as multi-chip standalone cryptographic modules and validated at the following FIPS 140-2 Section levels:

Table 1 - Security Level Per FIPS 140-2 Section

8

9

6

7

10

11

Section

1

Section Title

Cryptographic Module Specification

4

5

2

3

Cryptographic Module Ports and Interfaces

Roles, Services, and Authentication

Finite State Model

Physical Security

Operational Environment

Cryptographic Key Management

EMI/EMC

Self-tests

Design Assurance

Mitigation of Other Attacks

Level

1

1

1

1

1

N/A

1

1

1

1

N/A

1.3 Module Interfaces

The VSX 3000, VSX 5000, and VSX 7000s are multi-chip standalone modules that meet overall level 1 FIPS 140-2 requirements. The cryptographic boundaries of the VSX 3000, VSX 5000, and VSX 7000s are defined by the hard plastic or metal covers that include all the hardware and software components as shown in figures Figure 1 through

Figure 5.

Ports and interfaces on the module can be categorized as the following FIPS 140-2 logical interfaces:

Data Input Interface

Data Output Interface

Control Input interface

Status Output Interface

Ports and interfaces of the VSX 3000 system are shown in Figure 6 below. The ports on the module’s connector panel are listed below, and mapped to logical interfaces in Table 2 below.

BRI connectors – For ISDN calls

Stereo connector – For headphones or desktop speakers

Composite video connector – Video input to the system from camera or VCR/DVD

Audio connector – Audio input to the system from VCR/DVD

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 8 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

LAN connector – For IP calls, VSX Web, and remote management

Power connector – For power supply

Power switch for the codec – (one of three)

VGA connector – For Personal Computer (PC) to use system as a computer monitor and for passing the video image from the VGA input connector to a display device

LCD Screen – Screen for video conferencing

IR Sensor – Input from IR sensor

Speaker – Built-in speaker

Camera – Input for video conferencing

Microphone – Built-in microphone

LED – LEDs indicate system status

Figure 6 - VSX 3000 Connector Panel

The VSX 3000 physical interfaces are located under the system as depicted in Section 2 of the Administrator’s

Guide for the VSX Series, which lists on page one and two the connection cables required for the system. The following table maps VSX 3000 interfaces with FIPS 140-2 logical interfaces:

Table 2 - Mapping of FIPS 140-2 Logical Interfaces to VSX 3000, VSX 5000, and VSX 7000s Interfaces

FIPS 140-2 Logical Interface

Data Input

Data Output

Control Input

Status Output

Power

VSX 3000, VSX 5000, and VSX 7000s Port/Interface

BRI connectors, Composite video connector, LAN connector, VGA connector, Audio

Connector, Microphone, Camera

BRI connectors, Stereo connector, LAN connector, LCD Screen, Speaker

LAN connector, IR Sensor, Power switch

LAN connector, LCD Screen, LEDs

Power connector

The following is the list of ports and interfaces of the VSX 5000 system and Figure 7 below shows the ports on module’s back panel.

Power connector – For power supply

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 9 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

LAN connector – For IP calls, VSX Web, and remote management

Conference link connector – For microphone pod, SoundStation VTX 1000, or Visual Concert VSX

VGA connector – VGA connector for input and passes the video image for monitor or projector

VCR/DVD inputs – For VCR/DVD to play content into calls

Power switch – To power up or down the device

Audio connectors – For main monitor audio, or for external speaker system

S-Video Connector – S-Video output for monitor

Serial port – RS-232 port for RS-232 device

IR Sensor – Input from IR sensor

Speaker – Built-in speaker

Camera – Input for video conferencing

LED – LEDs indicate system status

Figure 7 - VSX 5000 Back Panel

Section 1 of the Administrator’s Guide for the VSX Series lists the connection cables required for the system. The

Following table maps VSX 5000 interfaces with FIPS 140-2 logical interfaces.

Table 3 - Mapping of FIPS 140-2 Logical Interfaces to VSX 5000 Interfaces

FIPS 140-2 Logical Interface

Data Input

Data Output

Control Input

Status Output

VSX 3000, VSX 5000, and VSX 7000s Port/Interface

LAN connector, VGA connector, VCR/DVD inputs, Conference link connector, Serial Port, Camera

LAN connector, VGA connector, Audio connectors, S-Video Connector, Serial

Port, Conference link connector, Speaker

Conference link connector, LAN connector, Serial Port, IR Sensor, Power switch

VGA connector, S-Video connector, LAN connector, Serial Port, Conference link connector, LEDs

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 10 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

FIPS 140-2 Logical Interface

Power

VSX 3000, VSX 5000, and VSX 7000s Port/Interface

Power connector

The following is the list of ports and interfaces for the VSX 7000e system and Figure 8 below shows the ports on module’s back panel.

Network interface bay – For network interface module (for BRI, PRI, and V.35/RS-449/RS-530 connection)

VCR/DVD connector – Play VCR/DVD content into calls or record the calls to VCR/DVD

Audio connector – Input to system from ImageShare II and computer, or outputs to external speaker

Serial ports – RS-232 port for touch panel, camera control, or other RS-232 devices

S-Video connector – Input to system from camera or output for S-Video monitor

Analog phone connector – For analog phone line

Camera 1 control connector – For camera 1 PTZ control

VGA connector – Input to system for ImageShare II and computer VGA, or outputs to VGA monitor and projector

LAN connector – For IP calls, VSX Web, and remote management

Conference link connector – For microphone pod, SoundStation VTX 1000, or Visual Concert VSX

IR Sensor – Input from IR sensor

Power button – Controls power and provides system status

LED – LEDs indicate system status

Power connector – For power cord

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 11 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

Figure 8 - VSX 7000e Back Panel

Section 1 of the Administrator’s Guide for the VSX Series lists the connection cables required for the VSX 7000e system. The following table maps VSX 7000e interfaces with FIPS 140-2 logical interfaces.

Table 4 - Mapping of FIPS 140-2 Logical Interfaces to VSX 7000e Interfaces

FIPS 140-2 Logical Interface

Data Input

Data Output

Control Input

Status Output

Power

VSX 3000, VSX 5000, and VSX 7000se Port/Interface

Network interface bay, VCR/DVD connector, Audio connector, Serial ports, S-Video connector, Analog phone connector, VGA connector, LAN connector, Conference link connector

Network interface bay, VCR/DVD connector, Audio connector, Serial ports, S-Video connector, Analog phone connector, VGA connector, LAN connector, Conference link connector

Network interface bay, Serial ports, Camera 1 control connector, LAN connector,

Conference link connector, IR Sensor, Power button

Network interface bay, Serial ports, LAN connector, Conference link connector, Power button, LEDs

Power connector

The following list provides the ports and interfaces of the VSX 7000s system and Figure 9 below shows the ports on module’s back panel.

Power connector – Houses power for subwoofer and optional network interface module (for BRI, PRI, and

V.35/RS-449/RS-530 connection)

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 12 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

LAN connector – For IP calls, VSX Web, and remote management

Conference link connector – For microphone pod, SoundStation VTX 1000, or Visual concert VSX

VGA connector – Output from system for VGA monitor or projector

VCR/DVD connector – Play VCR/DVD connect into calls or record call content

Power switch

S-Video connector – Input from camera or output to S-Video monitor

Audio connector – Output from system for external speaker system

Serial RS-232 port – RS-232 port for touch panel, camera control, or other RS-232 device

IR Sensor – Input from IR sensor

Speaker – Built-in speaker

Camera – Input for video conferencing

LED – LEDs indicate system status

Figure 9 - VSX 7000s Back Panel

Section 1 of the Administrator’s Guide for the VSX Series lists the connection cables required for the system. The following table maps VSX 7000s interfaces with FIPS 140-2 logical interfaces.

Table 5 - Mapping of FIPS 140-2 Logical Interfaces to VSX 7000s Interfaces

FIPS 140-2 Logical Interface

Data Input

Data Output

Control Input

Status Output

Power

VSX 3000, VSX 5000, and VSX 7000ss Port/Interface

LAN connector, Conference link connector, VCR/DVD connector, Serial port, S-Video connector, Camera

LAN connector, VGA connector, VCR/DVD connector, S-Video connector, Audio connector, Serial port, Conference link connector, Speaker

LAN connector, Serial port, Conference link connector, IR Sensor, Power switch

LAN connector, VGA connector, Serial port, Conference link connector, LEDs

Power connector

The following is the list of ports and interfaces of the VSX 8000 system and Figure 10 below shows the ports on module’s connector panel.

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 13 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

Network interface bay – For network interface module (for BRI, PRI, and V.35/RS-449/RS-530 connection)

Balanced Audio connector – Input for mixed or powerful microphones or output for external audio equipment

VCR/DVD connector – Play VCR/DVD content into calls or record the calls to VCR/DVD

Serial ports – RS-232 port for touch panel, camera control, or other RS-232 device

Monitor 1Y and C – output for main monitor

S-Video connector – Input to system from camera or output for S-Video monitor

Audio connector –Output to external speaker

VGA connector – Input to system for ImageShare II and computer VGA, or outputs to VGA monitor and projector

LAN connector – For IP calls, VSX Web, and remote management

Conference link connector – For microphone pod, SoundStation VTX 1000, or Visual Concert VSX

IR Sensor – Input from external IR sensor

Analog phone connector – For analog phone line

Camera 1 control connector – For camera 1 PTZ control

Camera 1Y and C – Input from main camera

IR Sensor – Input from IR sensor

Power button – Controls power and provides system status

LED – LEDs indicate system status

Power connector – For power cord

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 14 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

Figure 10 - VSX 8000 Back Panel

Section 1 of the Administrator’s Guide for the VSX Series lists the connection cables required for the system. The following table maps VSX 8000 interfaces with FIPS 140-2 logical interfaces.

Table 6 - Mapping of FIPS 140-2 Logical Interfaces to VSX 8000 Interfaces

FIPS 140-2 Logical Interface

Data Input

Data Output

Control Input

Status Output

Power

VSX 3000, VSX 5000, and VSX 7000s Port/Interface

Network interface bay, Balanaced Audio connector, VCR/DVD connector, Serial port, S-Video connector, VGA connector, LAN connector, Conference link connector, Analog phone connector, Camera 1Y and C

Network interface bay, Balanaced Audio connector, VCR/DVD connector, Serial port, Monitor

1Y and C, S-Video connector, Audio connector, VGA connector, LAN connector, Analog phone connector, Conference link connector

Serial port, LAN connector, IR Sensor, Camera 1 control connector, Conference link connector, IR Sensor, Power switch

Serial port, LAN connector, Conference link connector, Power button, LEDs

Power connector

Please see User Guidance section of this document for list LEDs and description of their behavior.

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 15 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

1.4 Roles and Services

The modules support two authorized roles (as required by FIPS 140-2) that operators may assume: a Crypto Officer role and User role.

1.4.1 Crypto-Officer Role

The Crypto-Officer (CO) installs and uninstalls the cryptographic module. Also, the CO is responsible for monitoring and configuring the modules and call settings.

The Crypto-Officer can manage the VSX modules over a Transport Layer Security (TLS) v1 session through a web interface. Through this interface, the Crypto-Officer is able to configure the device and setup a call, change secure mode of operation, monitor current status and perform virtually all of the management of the module. Configuration of the modules and viewing of status can be performed with a Command Line Interface (CLI) over the local serial port or remotely via Telnet over TLS. All the management and configuration capabilities are available via the

VSX’s web interface are also available via secure telnet over TLS. The telnet interface includes additional debug commands that are not available over the web. The Crypto-Officer has access to the following services:

Table 7 - Mapping of Crypto-Officer’s Services to Inputs, Outputs, Critical Security Parameters (CSPs), and Access

Control

Service

Install

Description

Assemble the systems and setup network configurations

Uninstall

Run Self-Test

Room monitoring

Remote diagnostics

Call Detail Reports

Disassemble the VSX system

Perform the self-test on demand

Monitor meeting rooms in or out of a call using the Web

Director feature in

VSX Web.

Identify and correct issues that affect the user’s experience via

VSX Web interface.

Access the system’s call history using local or remote management interface.

System configuration Run the system setup wizard locally or remotely to get the system up and running.

Input

Command

Command

Command

Command

Command

Command

Command

Output

Result of installation

Uninstalled module

Status output

Status output

Status output

Modules’ settings and status output

Modules’ settings and status output

CSP and Access Control

None

None

None x.509 certificate – Read

Session key –Read/Write

CO password – Read x.509 certificate – Read

Session key –Read/Write

CO password – Read x.509 certificate – Read

Session key –Read/Write

CO password – Read x.509 certificate – Read

Session key –Read/Write

CO password – Read

1.4.2 User Role

Users access teleconferencing services via the LAN port (for IP calls) or the Network Interface Bay port (ISDN calls). Services provided for Users are given below in Table 8.

Table 8 - Mapping of User’s Services to Inputs, Outputs, CSPs, and Access Control

Service Description Input Output CSP and Access

Control

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 16 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

Service

Secured call on IP network

Description

Placing secured call on

IP network via LAN port

Secured call on ISDN Placing secured call on

ISDN via BRI/PRI port

Input

Command and calling information

Command and calling information

Output CSP and Access

Control

Connection established Diffie-Hellman key pairs – Read

IP Encryption Key –

Read/Write

Connection established Diffie-Hellman key pairs – Read

ISDN Encryption Key

– Read/Write

1.4.3 Authentication

The modules were not tested for role-based or identity-based authentication requirement as level 1 modules.

However, the modules authenticate Crypto-Officer with x.509 certificate during TLS handshake. The users do not authenticate themselves to the module.

1.5 Physical Security

The VSX 3000, VSX 5000, and VSX 7000s are multi-chip standalone cryptographic modules. The modules’ hardware is composed of production-grade components and the modules are entirely enclosed in solid metal cases.

These cases enclose all of the modules’ internal components and serve as the cryptographic boundaries for the modules.

The VSX systems were tested and found conformant to the Electromagnetic Interference/Electromagnetic

Compatibility (EMI/EMC) requirements specified by 47 Code of Federal Regulations, Part 15, Subpart B,

Unintentional Radiators, Digital Devices, Class A (i.e., for business use).

1.6 Operational Environment

The operational environment requirements do not apply to the VSX 3000, VSX 5000, and VSX 7000s. The modules do not provide a general purpose Operating System (OS) and only allow the updating of image components after checking a Digital Signature Algorithm (DSA) signature on new software images.

1.7 Cryptographic Key Management

The VSX modules implement the following FIPS-approved algorithms:

AES (CBC, OFB) - key sizes 128, 192, 256 (Cert #431)

FIPS 186-2 Appendix 3.1 PRNG (Cert #224)

Secure Hashing Algorithm (SHA-1) – Byte oriented (Cert #501)

TDES (CBC) 1, 2, 3 keying options (Cert #460)

DSA (verify) 1024 bits (Cert #178)

Additionally, the module utilizes the following non-FIPS-approved algorithm implementation:

Diffie-Hellman (key agreement, key establishment methodology provides 80-bits of encryption strength)

RSA (key wrapping, key establishment methodology provides 80-bits of encryption strength)

Hardware Random Number Generator (RNG) – for seeding the FIPS-approved deterministic RNG

The module supports the following critical security parameters:

Table 9 - List of Cryptographic Keys, Cryptographic Key Components, and CSPs

Key Key Type Generation /

Input

Output Storage Zeroization Use

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 17 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

Key

x.509 certificate

(RSA Public key)

Key Type

1024 bits RSA public key

RSA Private key 1024 bits RSA private key

Diffie-Hellman public key

Diffie-Hellman private key

Integrity Check

Key

Session Key

1024 bits public key

1024 bits private key

Generation /

Input

Generated externally, input in plaintext

Generated externally, input in plaintext

Generated internally

Generated internally

1024 bits DSA

Public key

Generated externally, inputted in plaintext

192 bits TDES

CBC key

Generated internally during

TLS handshake

IP Encryption

Key

ISDN

Encryption Key

PRNG seed

128 bits AES

CBC key

Generated internally during

Diffie-Hellman key agreement

128, 192, 256 bits AES OFB keys

Generated internally during

Diffie-Hellman key agreement

20 bytes of seed value

Internally generated

Output

Output in plaintext

Output in plaintext

Never exits the module

Never exits the module

Never exits the module

Never exits the module

Storage

Stored in volatile memory

Stored in volatile memory

Stored in Flash in plaintext

Held in volatile memory in plaintext.

Held in volatile memory in plaintext.

Zeroization

Stored in Flash in plaintext

Erasing the flash image

Never exits the module

Stored in Flash in plaintext

Erasing the flash image

Zerorized on reboot.

Zerorized on reboot.

Erasing the flash image

Exits in encrypted form

(RSA key transport)

Held in volatile memory in plaintext.

Zerorized on reboot.

Zerorized on reboot.

Zerorized on reboot.

Never exits the module

Held in volatile memory only in plaintext.

Zerorized on reboot

Use

Authenticates the module during

TLS handshake

Authenticates the module during

TLS handshake

Establishes a session key (IP or

ISDN Encryption

Key) during

H.323 negotiation

Establishes a session key (IP or

ISDN Encryption

Key) during

H.323 negotiation

Checks integrity of the software at power-up of the module

Encrypts TLS traffic

Encrypts IP calls

Encrypts ISDN calls

Produce FIPS approved random number

1.7.1 Key Generation

The modules generate symmetric keys and FIPS-approved PRNG seeds internally. The symmetric keys (Session

Key, IP Encryption Key, and ISDN Encryption Key) and Diffie-Hellman key pair are generated using a FIPSapproved 186-2 Appendix 3.1 algorithm. Twenty bytes of hardware generated noise is used to create a PRNG seed, and RSA key pair is generated externally and input into the module in plaintext.

1.7.2 Key Input/Output

Rivest, Shamir, Adleman (RSA) key pair is generated externally and input to the modules in plaintext. The RSA private key and DH private key never exit the module, while the public keys are output in plaintext. The Session key exits the module in encrypted form during TLS handshakes (protected within RSA key transport). The IP Encryption

Key and ISDN Encryption Key are never output from the module. Other CSPs and keys, such as the Integrity Check

Key and PRNG seed are never output from the modules.

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 18 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

1.7.3 Key Storage

The RSA public/private key pair and Integrity Check Key are stored in the modules’ flash drives in plaintext form.

The Session Key, IP Encryption Key, ISDN Encryption Key, DH public/private key pair, and PRNG seed are held in volatile memory in plaintext.

1.7.4 Key Zeroization

The RSA key pair is zeroized by overwriting the flash image. The Session Key, IP Encryption Key, ISDN

Encryption Key, Diffie-Hellman (DH) private/public key pair and PRNG seed are available only temporarily in volatile memory during video calls. These ephemeral keys and CSP are zeroized after the session is closed or whenever power is cycled.

1.8 Self-Tests

The VSX 3000, VSX 5000, and VSX 7000s perform the following self-tests at power-up:

Software integrity check using a DSA signature verification

Known Answer Tests (KATs) o

AES Known Answer Test (KAT) o

Triple-DES KAT o

RSA pairwise consistency check o FIPS 186-2 Appendix 3.1 PRNG KAT

The cryptographic modules also perform the following conditional self-tests:

Continuous RNG for FIPS 186-2 PRNG

Continuous RNG for non-approved RNG for entropy gathering

If any of the power-up self-test fails, the modules log the failure, and notification is provided to Crypto Officers through serial traces. Security relevant module functionality is not provided until all self-tests are passed.

In case a self-test fails, the logged trace indicates which self-test failed, and the modules display a warning message indicating the required reboot for the system. Since these messages are not available through the Secure Telnet interface before all self-tests have passed, the messages are echoed to any connected monitor screen.

1.9 Design Assurance

Polycom uses automated Configuration Management (CM) of their source code modules, organizing source code into separate version-controlled depots. Polycom uses Accurev’s TimeSafe® Configuration Management System to perform automated source code control. Additionally, Microsoft Visual Source Safe (VSS) version 6.0 is used to provide configuration management for the module’s FIPS documentation. This CM software and Polycom’s process provides access control, versioning, and logging for all module source code and documentation.

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 19 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

2 Secure Operation

The VSX 3000, VSX 5000, and VSX 7000s meet Level 1 requirements for FIPS 140-2. The sections below describe how to place and keep the module in FIPS-approved mode of operation.

2.1 Crypto-Officer Guidance

The Crypto-Officer is responsible for initialization and security-relevant configuration and management of the module through the web management interface, serial port from a non networked PC, or secure Telnet over TLS.

Please see Polycom’s Administrator’s Guide for the VSX Series for more information on setting up, configuring and maintaining the modules.

2.1.1 Initialization

The Crypto-Officer is responsible for putting the modules in FIPS mode of Operation, by enabling the system to automatically encrypt calls. AES encryption is a standard feature on all VSX systems. The system will be shipped by default in Non-Secure Mode. To put the modules in FIPS mode of Operation, the Crypto-Officer must: o

Go to System

Admin Settings

System Security

o

Select Secure Mode o

Selecting the Secure mode will result in a system reset o

The change of mode from Non-Secure mode to secure mode shall initiate Crypto-Officer password change request

2.1.2 Management

Following are the points of System behavior in FIPS mode of Operation: o Default password (System Serial number) or Dummy password (No password), is not allowed for

'admin' login in the secured mode. o

Only https over TLS, secure telnet, and secure FTP connections are allowed in the secured mode. The standard http connections with no security will not be allowed. o Media encryption during a call (H.323/H.320) will always be set to ON (AES-Encryption ON)

The following table details the port number to be used for secure applications, telnet, FTP, and https over TLS.

Application

TLS Telnet Debug Port

TLS Telnet API Port

TLS FTP for control Connection

TLS FTP for data Connection

TLS http

Port Number

992

993

990

989

443

The Crypto-Officer is able to monitor and configure the module via the web interface (https over TLS), serial port, or via secure telnet (Telnet over TLS). Detailed instructions to monitor and troubleshoot the systems are provided in the Administrator’s Guide for the VSX Series.

Software upgrade is not allowed in FIPS mode of Operation.

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 20 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

2.2 User Guidance

The User does not have the ability to configure sensitive information on the module. They only access the secured communication functionality of the module. Users can find the basic instructions to use the VSX systems in Getting

Started Guide for the VSX Series.

Users are responsible for determining when to place encrypted video calls, determining when they wish to verify encryption keys with the other side on a video call, and whether they wish to hang up a video call if encryption cannot be setup or keys verified. Users may not place unencrypted calls in FIPS mode of operation.

The module has several LEDs that help users to understand systems’ general status. The modules have a dedicated

LED at front or transparent power button light to indicate system status. Description of the LED status is described in the Table 10 below.

Table 10 - LED/Power Button Light Description

Model

VSX 3000 (LED)

VSX 5000 (LED)

VSX 7000e (Power Button)

VSX 7000s (LED)

VSX 7000e (Power Button)

VSX 8000 (Power Button)

Description

Indicators are off

Green indicator blinks slowly

Green indicator flashes when you use the remote control

Amber indicator flashes when you use the remote control

Green indicator is on

Amber indicator is on The system is in a call.

VSX 3000: Red indicator is on

VSX 5000, VSX 7000s: Mute indicator on the Polycom microphone is red

Blue indicator is on

Green indicator is on

Green indicator blinks

Red indicator turns on momentarily

Mute indicator on the Polycom microphone is red

Modules’ Status

No power to the system.

The system is sleeping.

The system is not in a call, and is receiving signals from the remote control.

The system is in a call, and is receiving signals from the remote control.

The system is ready to make a call.

Amber indicator is on The system is in a call.

The system microphone is muted.

The system is connected to power but powered off.

The system is powered on.

The remote control has been picked up or set down.

The system is powering off.

The system microphone is muted.

On VSX 5000, VSX 7000e, VSX 7000s, and VSX 8000 systems, the BRI network interface lights are located on the network interface module. On the VSX 3000 system, the lights are located on the back of the system near the BRI connectors.

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 21 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0 June 15, 2007

Table 11 - BRI Network Interface LEDs

LED Status Status Description

Indicators are off

Green indicator is on

No power to the system, or

The system is not connected to the network, or

The system is not receiving a clock signal from the network, or

The system is restarting

The system is receiving a clock signal from the network.

Yellow indicator is on

The system is able to make a call.

Green and yellow indicators are on

The system is receiving a software update, or

The system is operating normally.

The PRI network interface is available for VSX 7000e, VSX 7000s, and VSX 8000 systems.

Table 12 - PRI Network Interface LEDs

LED Status

Indicators are off

Red indicator is on or blinking

Status Description

No power to the system.

The system is not connected to the ISDN network, or there is a problem with the ISDN line.

Yellow indicator is on or blinking There is a problem with the ISDN line.

Green indicator is on The system is able to make and receive calls.

The serial V.35/RS-449/RS-530 network interface is available for VSX 7000e, VSX 7000s, and VSX 8000 systems.

Table 13 - V.35/RS-449/RS-530 Network Interface LEDs

LED Status

Indicators are off

Yellow indicator is on

Yellow and green indicators are on The system is in a call.

Status Description

No power to the system, or

The system is not communicating with the network, or

The system is restarting.

The system is receiving a clock signal from the network (able to make a call).

Yellow and green indicators are on The system is in a call.

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 22 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

Non-Proprietary Security Policy, Version 1.0

3 Acronyms

Table 14 - Acronyms

Acronym

API

Definition

Application Programming Interface

BRI

CLI

Basic Rate Interface

Command Line Interface

CM Configuration Management

CMVP Cryptographic Module Validation Program

CSP

DH

Critical Security Parameter

Diffie-Hellman

DSA Digital Signature Algorithm

EMC Electromagnetic Compatibility

EMI Electromagnetic Interference

FIPS Federal Information Processing Standard

IP Internet Protocol

ISDN Integrated Services Digital Network

KAT Known Answer Test

NIST National Institute of Standards and Technology

OS

PC

Operating System

Personal Computer

PRI ISDN Primary Rate Interface

RNG Random Number Generator

RSA

SHA

Rivest Shamir and Adleman

Secure Hash Algorithm

TLS Transport Layer Security

VSS Visual Source Safe

June 15, 2007

Polycom VSX 3000, VSX 5000, and VSX 7000s Page 23 of 23

© 2007 Polycom, Inc. -

This document may be freely reproduced and distributed whole and intact including this Copyright Notice.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement