Renesas E6000 Network Card User Manual


Add to my manuals

advertisement

Renesas E6000 Network Card User Manual | Manualzz

To all our customers

Regarding the change of names mentioned in the document, such as Hitachi

Electric and Hitachi XX, to Renesas Technology Corp.

The semiconductor operations of Mitsubishi Electric and Hitachi were transferred to Renesas

Technology Corporation on April 1st 2003. These operations include microcomputer, logic, analog and discrete devices, and memory chips other than DRAMs (flash memory, SRAMs etc.)

Accordingly, although Hitachi, Hitachi, Ltd., Hitachi Semiconductors, and other Hitachi brand names are mentioned in the document, these names have in fact all been changed to Renesas

Technology Corp. Thank you for your understanding. Except for our corporate trademark, logo and corporate statement, no changes whatsoever have been made to the contents of the document, and these changes do not constitute any alteration to the contents of the document itself.

Renesas Technology Home Page: http://www.renesas.com

Renesas Technology Corp.

Customer Support Dept.

April 1, 2003

HS3160EPI60HE-P(C)

Precautions on Using the H8/3160 Series E6000 Emulator

This section shows notes on using the H8/3160 Series E6000 Emulator.

1 Precautions on Using the Emulator

1.1 Note on Compatibility of Session File

There is the following note on a session file that has been created at emulation of the H8/3164 device.

• The session file, which has been created with H8/3160 E6000 Emulator HDI System V3.30 or earlier version, cannot be loaded with H8/3160 E6000 Emulator HDI System V3.30 or later version.

(The 'Invalid target system E6000 H8/3164 Emulator' message is displayed.)

To solve this problem, a session file should be edited.

Open a session file (having the '.hds' or '.hdt' extension) by using a text editor (such as Notepad), and replace and save the character string 'H8/3164' in the session file as 'H8/3164(AE350)'.

1.2 MAP

• Modification of MAP attribution

Reserved area from address H’FFD0 cannot be changed to emulation memory.

1.3 Trace

The code display is invalid when address range is specified as a trace acquisition condition. Use the code display only for reference.

1.4 Temporary Breakpoint

• Run... (Run menu)

Do not set temporary breakpoints to an area wherein PC Break (Not used area) cannot be set. If set, user program execution will not stop at the breakpoint. Moreover, the On Chip Breakpoint may remain. In this case, delete the breakpoint from the [Breakpoints] window.

1.5 Monitor

• Execution status display on status bar

At memory access wait, not the address where access is halted, but the next fetched address is displayed.

1.6 The Load/Save of the Session File

Load the file after you confirm that the H/W environment is the same as that when the last session file was loaded.

Note that the operation of HDI may become incorrect when Target Clock is chosen at the time when the session file was saved and Target was not connected at the time when the session file was loaded.

1.7 Load Memory

During loading memory, if loading is stopped by [Halt] from the [Run] menu, there may be no responses from the HDI for a few seconds. For loading file, use [Load Program] from the [File] menu.

Note: Microsoft

®

, Windows

®

, Windows

®

95, Windows

®

98, Windows NT

®

, and Windows

®

2000 are registered trademarks of Microsoft Corporation in the United States and/or other countries.

1 / 4

1.8 [Disassembly] Window

At address specification to open the [Disassembly] window, when a value larger than the maximum one of the absolute address is input, the contents of the last address may not be displayed. In this case, do not perform scrolling with the scroll box on the scroll bar in the [Disassembly] window.

If nothing is displayed on the Code or Assembly column in the [Memory] window or [Disassembly] window, close and open again the [Memory] window or [Disassembly] window.

1.9 [Trace] Window

• Note when the Number of Acquired Records is 1

When the number of acquired trace records is 1, the trace result may not be displayed on the [Trace] window.

If no data is displayed on the [Trace] window even if "Trace - 1 record (no filter)" is displayed on the title bar in the [Trace] window, open the [Trace] window again.

When the trace is acquired with the trace window opened and when the number of acquired records is 1, the displayed data is illegal. Update the data by reopening the [Trace] window.

• Note when Time Stamp Setting is Changed

Even if the valid/invalid setting for the Time Stamp is switched in the [Trace Acquisition] dialog box, the header character string in the [Trace] window is not changed.

When the valid/invalid setting is switched, open the [Trace] window again.

• Filter

When the trace filter function is used, the information of the Address and Source columns in the [Trace] window does not match. When the filter function is used, ignore the source information displayed on the

Source column.

1.10 [Memory Mapping] Dialog Box

Even if the [Reset] button is clicked, the mapping information is not reset to the default setting. When the mapping information is reset to the default setting, once close the [Memory Mapping] dialog box with the

[Close] button after clicking the [Reset] button.

1.11 Note on Setting Change Operation from BP Column

When the execution time measurement start point (+Time) or trace start point (+Trace) is clicked with the right mouse button, a pop-up menu is displayed. An item in this pop-up menu may not be changed to another one. In this case, change the item with double-clicking or from the [Breakpoints] window or

[Trace] window directly.

1.12 Note on [Registers] Window Operation during Program Execution

During program execution, when the [Registers] window is double-clicked, a dialog box to change the register contents is displayed. However, the operation to change the register contents during program execution becomes invalid.

1.13 [Breakpoints] Window

During user program execution, it is impossible to jump to the corresponding source line or address line on the [Source] or [Disassemble] window from a breakpoint by using Go to Source in the pop-up menu that is displayed on the [Breakpoints] window.

1.14 Profile Function

The E6000 HDI does not support the profile function (section 13.10, Profile-List, section 13.11, Profile-

Tree, and section 13.12, Profile-Chart, described in Hitachi Debugging Interface User's Manual).

1.15 [I/O Registers] Window

The E6000 HDI does not support the invalid module display and bit information display in the [I/O

Registers] window (described in section 8, Displaying Variables, in the Hitachi Debugging Interface User's

Manual).

1.16 Compare Memory

The Compare Memory function, which can be used by selecting [Compare...] from the [Memory] menu, is not supported.

2 / 4

1.17 [Select Function] Dialog Box

The E6000 HDI does not support software breakpoint setting in the [Select Function] dialog box

(described in section 10, Selecting Functions, in the Hitachi Debugging Interface User's Manual).

1.18 Note on Radix in [Register] Dialog Box

The default input radix in the [Register] dialog box is hexadecimal regardless of the Radix setting. If you want to input the radix other than hexadecimal, specify the prefix code such as B'.

1.19 Note on Moving Source File Position after Creating Load Module

When the source file is moved after the load module has been created, the [Open] dialog box, which specifies the source file, may be displayed during debugging the created load module. Select the corresponding source file and click the [Open] button.

1.20 Source-Level Execution

• Source file

Do not display source files that do not correspond to the load module in the program window. For a file having the same name as the source file that corresponds to the load module, only its addresses are displayed in the program window. The file cannot be operated in the program window.

• Step

Even standard C libraries are executed. To return to a higher-level function, enter Step Out. In a for statement or a while statement, executing a single step does not move execution to the next line. To move to the next line, execute two steps.

1.21 Watch

• Local variables at optimization

Depending on the generated object code, local variables in a C source file that is compiled with the optimization option enabled will not be displayed correctly. Check the generated object code by displaying the [Disassembly] window.

• Variable name specification

When a name other than a variable name, such as a symbol name or a function name, is specified, no data is displayed.

Example: The function name is main.

main =

• Array display

When array elements exceed 1000, elements from after 1000 will not be displayed.

1.22 Line Assembly

• Input radix

Regardless of the Radix setting, the default for line assembly input is decimal. Specify H’ or 0x as the radix for a hexadecimal input.

• Address space size

In absolute addressing mode, specify the size (:16, etc.)

1.23 Command Line Interface

• Batch file

To display the message “Not currently available” while executing a batch file, enter the sleep command.

Adjust the sleep time length which differs according to the operating environment.

Example: To display “Not currently available” during memory_fill execution: sleep d’3000 memory_fill 0 ffff 0

• Overwrite file

In Command Line Interface, a file having the same name as the output file is overwritten without asking the user.

3 / 4

1.24 Usage with Another HDI

• Automatic load of session files

Since the emulator cannot use another HDI, re-install this HDI whenever another HDI has been previously installed is used.

If another HDI has been used, initiate this HDI with "Run" as follows without using the session files.

<Directory path name in which HDI is installed>\hdi /n (RET)

/n initiates the HDI without loading the recently used session files.

If there is another session file in the different debug platform, the following error message is displayed: invalid target system: <recently used debug platform name>

• Uninstallation of Another HDI

When another HDI is uninstalled after installing this HDI, the stack trace function cannot be used. To use this function, re-install this HDI.

1.25 Limitations when Using Old Version of Windows 95

When using the old released version (4.00.950a, etc.) of Windows

95, an illegal operation may occur; for example, the HDI is abnormally terminated by an application error if [Options...] is selected from the

[Setup] menu. This is because of the old version of COMCTL32.DLL in the System directory in the

Windows directory. Download the updated program of COMCTL32.DLL from the Microsoft

 homepage, or update the version of Windows

95.

2 User's Manual

2.1 Emulator User's Manual

In the E6000 emulator user's manual, some screen bitmap may be different from actual ones. For details on functions, refer to the on-line help or Hitachi Debugging Interface User's Manual.