36" CirCulating louvered Firebox oWner’S inStallation Manual
O-TL REPORT # 114-F-20-4
C36eMW-rC with brushed brass Finish bi-fold doors
C36eMW-rbC with black
Finish bi-fold doors
C36eMW-rPlC with Platinum
Finish bi-fold doors
Includes Manual
Control Fan System and Combustion
Air Kit
SAVE THIS BOOK
This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed. Keep it with your other important papers.
This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log approved to
ANS Z21.60, Z21.84 or RGA 2-72 standards or for use with a vent-free gas log heater approved to ANS Z21.11.2 standard. A vent-free log can only be installed in an aftermarket (completion of sale, not for purpose of resale from the manufacturer), permanently located, manufactured (mobile) home, where not prohibited by local codes. Approved hood must be installed when using a vent-free gas log heater (see Accessories, page 18).
This firebox meets the construction and safety standards of H.U.D. for application in mobile homes when installed according to these instructions.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
For more information, visit www.desatech.com
table oF ContentS
Safety .................................................................. 2
Specifications ...................................................... 3
Fireplace Installation............................................ 3
Venting Installation .............................................. 6
Optional Gas Line Installation............................ 13
Finishing Fireplace ............................................ 15
Operation and Maintenance Guidelines ............ 15
Replacement Parts ............................................ 17
Technical Service............................................... 17
Accessories ....................................................... 18
SaFety
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury, property damage or loss of life. Refer to this manual for assistance or additional information. Consult a qualified installer or local distributor.
CAUTION: The structural integrity of the mobile home floor and ceiling/roof must be maintained.
WARNING: Do not install a fireplace insert in this box unless the manufacturer's instructions with the insert specifically state this fireplace has been tested for use with the insert.
IMPORTANT: Check HUD requirements before installing this fireplace.
The C36EMW Series is specifically designed for use in manufactured mobile homes. These fireplaces include a manual control fan system, combustion air kit and bi-fold doors.
Before beginning the installation of the fireplace, read these instructions through completely.
• This Style Crest fireplace and its components are safe when installed according to this installation manual. Unless you use
Style Crest approved components, which have been designed and tested for the fireplace system, you may cause a fire hazard.
• The Style Crest warranty will be voided by and Style Crest disclaims any responsibility for the following actions.
a. Modification of the fireplace, components, doors, blower, fans, air inlet system and damper control.
b. Use of any component part not manufactured or approved by Style Crest in combination with a Style Crest fireplace system.
Proper installation is the most important step in ensuring safe and continuous operation of the fireplace. Consult the local building codes as to the particular requirements concerned with the installation of all factory built fireplaces. Although grounding may not be required by code, the manufacturer recommends it.
FOR YOUR SAFETY
• Do not store or use gasoline or any other flammable vapors or liquids in the vicinity of this or any other appliance.
• Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
• Do not place clothing or other flammable materials on or near the appliance.
• Never leave children unattended when a fire is burning in the fireplace.
This fireplace is not intended to be used as a substitute for a furnace to heat an entire home. Use for supplemental heat only.
This wood burning fireplace complies with the UL 127 standard as a FACTORY BUILT FIRE-
PLACE and is listed and tested by OMNI Test Laboratories.
2 www.desatech.com
124558-01A
SPeCiFiCationS
Round Top Termination
Storm Collar
Flashing
42"
36 1 /
4
"
22 1 /
8
"
33 1 /
4
"
6 3 /
4
"
36"
41"
3"
1"
0" To Top
Spacer
1/2" Air Space
Back and Sides
J-Box
Access
RH SIDE VIEW
Gas Line Conduit
Sleeve (Both Sides)
Firestop
Thimble
22 1 /
16
"
Firestop
1" Airspace
To Combustible
Materials
5/8"
Combustible
Wall Board
No Combustible
Material On Face
13"
7 3 /
4
"
9 3 /
8
"
LH SIDE VIEW
0" To
Bottom
Rear View of Fireplace
8" Each
Side
Not Less Than 14"
To Perpendicular
Sidewall
Hearth Extension
52" x 16"
Opening for
Outside Air
9 1 /
2
"
14" 14"
FirePlaCe inStallation
SELECTING LOCATION
To determine the safest and most efficient location for the fireplace, you must take into consideration the following guidelines:
1. The location must allow for proper clearances (see Figures 1 and 2, page 4).
2. Consider a location where the heat output will not be affected by drafts, air conditioning ducts, windows or doors.
3. A location that avoids the cutting of joists or roof rafters will make installation easier.
4. An outside air kit is available with this fireplace (see Outside Air Kit on page 6).
WARNING: Do not install this appliance in a bedroom.
124558-01A www.desatech.com
3
42 1 /
4
"
41 3 /
4
"
FirePlaCe inStallation
Continued
22 5 /
8
"
10"
Maximum height of any system is 40 feet.*
This measurement includes fireplace, chimney sections and height of termination assembly at level of flue gas outlet (see Figure 3).
*For manufactured home application, minimum height is 11' for straight flue or flue with one elbow set. Maximum height of any system is 20'.
Effective Height of
Termination Cap RT-8DM
Effective Height of
Termination Cap RT-8DM
Figure 1 - Framing Dimensions
Maintain 1/2" Air Space
Between Framing and Fireplace
13" Min.
43 5 /
8
"
Min.
14' Min.
Height
11' for
Manufactured
Home
Application
14' Min.
Height
11' for
Manufactured
Home
Application
2' Max
Pipe Length
41 3 /
4
" Min.
61 11 /
16
" Min.
Figure 2 - Corner Installation
MINIMUM CLEARANCE TO
COMBUSTIBLES
Back and sides of fireplace 1/2" minimum*
Floor**
Wall to front of fireplace
0" minimum
36" minimum
Perpendicular wall to opening 14" minimum
Top spacers 0" minimum
Termination Cap RT-8DM see Mantels, page 15
Chimney outer pipe surfaces 1" minimum
RT-8DM
* Not required at nailing flanges
** See step 2 of Framing, page 5
14' Min.
14' Min.
WARNING: Do not pack required air spaces with insulation or other materials.
Home
Application
Minimum/Maximum Chimney Height
Minimum height ofthe chimney, measured
Pipe Length from base of fireplace to flue gas outlet of termination, is 14 feet* for straight flue or a between elbows is 2 feet.
Installation Installation
RT-8DM
Effective Height of
Termination Cap
40' Max.
Height
20' for
Manufactured
Home
Application
30E-8DM
Alternate
Installation
Alternate Installation
Figure 3 - Standard and Alternate
Venting Installation
4 www.desatech.com
124558-01A
RT-8DM
Effective Height of
Termination Cap
40' Max.
Height
20' for
Manufactured
Home
Application
30E-8DM
FRAMING
1. Frame opening for fireplace using dimensions shown in Figures 1 and 2.
2. If fireplace is to be installed directly on carpeting, tile (other than ceramic) or any combustible material other than wood flooring, fireplace must be installed on a metal or wood panel extending full width and depth of fireplace. (It is acceptable to cover two outside ends or columns of top louver panel leaving four center columns open).
3. Set fireplace directly in front of this opening and slide unit back until nailing flanges touch side framing.
4. Check level of fireplace and shim with sheet metal if necessary.
5. Before securing fireplace to prepared framing, metal ember protector (provided) must be placed between hearth extension (not supplied) and under bottom front edge of fireplace to protect against glowing embers falling through. If fireplace is to be installed on a raised platform, a Z-type ember protector (not supplied) must be fabricated to fit your required platform height. Ember protector should extend under fireplace a minimum of 1 1 /
2
". The ember protector should be made of metal material.
6. Using screws or nails, secure fireplace to framing through flanges located on sides of fireplace (see Figure 4).
FirePlaCe inStallation
Continued
HEARTH ExTENSION
A hearth extension projecting a minimum of
16" in front of and a minimum of 8" beyond each side of the fireplace opening is required to protect combustible floor construction in front of the fireplace. Use an equal material which meets the following specifications: a layer of noncombustible, inorganic material having a thermal conductivity of K=0.84 BTU
IN/FT, HR. F (or less) at 1" thick. For example, if the material selected has a K factor of 0.25, such as glass fiber, the following formula would apply:
0.25 x 1.0" = 0.30" thickness required
0.84
Thermal conductivity "K" of materials can be obtained from the manufacturer or supplier of the noncombustible material. If the hearth extension is to be covered, use noncombustible material such as tile, slate, brick, concrete, metal, glass, marble, stone, etc. Provide a means to prevent hearth extension from shifting and seal gap between fireplace frame and hearth extension with a noncombustible material (see Figure 5).
WARNING: Hearth extension is to be installed only as shown in Figure 5.
Fireplace
Front
Ember
Protector
Seal Gap
Nailing
Flange Screw or Nail
Raised
Hearth
NO
DO NOT Block Louvers
Seal Gap
Fireplace Front
Elevated
Ember
Protector
Hearth
Extension
Figure 5 - Hearth Extension
Figure 4 - Nailing Flanges
124558-01A www.desatech.com
5
FirePlaCe inStallation
Continued
FAN KIT ASSEMBLY (BK2)
A fan kit assembly is preinstalled in this fireplace. Use of blowers or fans other than model BK2 voids warranty. Fan is operated by pressing rocker switch located at lower right hand corner of fireplace face. Fan kit electrical connections are made through electrical cover plate located on side of fireplace as shown in Figure 6.
5. Secure electrical cover plate with screws previously removed.
6. Tighten strain relief plastic screw
Note: Electrical housing and cover plate have sharp edges. Wear protective gloves.
Screws
Rocker
Switch
Strain
Relief
Electrical
Cover Plate
Figure 6 - Fan Kit BK2 Electrical Cover
Fan Kit Wiring Instructions
1. Loosen strain relief by turning plastic screw counterclockwise.
2. Remove electrical cover plate (with strain relief) from fireplace by removing two sheet metal screws .
3. Slide power source wiring through strain relief opening and electrical cover plate and make all necessary connections
4. Place all wiring connections into electric housing as shown in Figure 7.
ELECTRICAL COVER PLA
PRE-WIRED RECEPT
Figure 7 - Fan Kit Wiring Diagram venting inStallation
OUTSIDE AIR KIT
Installation of an outside air kit should be completed during the rough framing of fireplace due to nature of its location. The supplied flex duct measures approximately
10" compressed and up to approximately 36" extended. Outside combustion air is accessed through mobile home floor using air kit model
AK6E or a side wall using air kit model AK6-
WE (see Accessories on page 18).
Installer may choose either left or right side mounting to allow for proper wall/rafter clearances.
For AK6-WE Only: Construct a 4.5" x 4.5" framing or opening on exterior wall (see
Figure 8, page 7).
For AK6E Only: The outside air vent is installed through a ventilated crawl space (see
Figure 9, page 7).
6 www.desatech.com
124558-01A
Insert Inner Tab of
Inlet Tube into Slot on Outer Surround venting inStallation
Continued
Insulation
Air Vent Location
Must Allow for Bushes,
Snow and
Other Possible
Obstructions
Left Side
Mounting
Shown
Secure to Collar with
Metal Tape, Screws or
Tie Straps
Outside
Air Vent
Termination
Insert Inner Tab of
Inlet Tube into Slot on Outer Surround
Figure 8 - Outside Air Kit AK6-WE Installation
Insulation
Left Side
Mounting
Shown
Secure to Collar with
Metal Tape, Screws or
Tie Straps
Flex Duct
Extends
Up to 36"
Floor
CHIMNEY PIPE
The chimney system approved for this fireplace consists of 12", 18", 24", 36" and
48" snap-lock, double-wall pipe segments, planned for maximum adaptability to individual site requirements. Actual lengths gained after fitting overlaps must be taken into consideration (lineal gain) and are given in the lineal gain chart (see Figure 10). Lineal Gain is the actual measurable length of a part after two or more parts are connected.
8"
Stainless
Inner Pipe
Hemmed
End
Figure 9 - Outside Air Kit AK6E
Installation
12 3 /
8
"
Galvanized
Outer Pipe
1. Locate and remove air inlet cover plate on fireplace‘s outer surround. Save screws.
2. Cut out any visible insulation that may obstruct airflow.
3. Extend flex duct to attach air inlet tube.
4. Insert inner tab of inlet tube into mating slot next to opening.
5. Place outer tab of inlet tube over mating hole next to opening and secure with screws removed from cover plate in step 1.
6. Install outside air vent termination in a location that will not be obstructed by bushes, snow, etc. Locate vent near the fireplace to make flex duct installation easier.
124558-01A www.desatech.com
Figure 10 - Lineal Gain
LINEAL GAIN
PART NO.
C36EMW-R
12-8DM
18-8DM
DESCRIPTION
Fireplace
Pipe Section
Pipe Section
GAIN
42"
10 5 /
8
"
16 5 /
8
"
24-8DM
36-8DM
Pipe Section
Pipe Section
23 5 /
8
"
34 5 /
8
"
48-8DM Pipe Section 46 5 /
8
"
RTL-8DM Round Termination 7 3 /
4
"*
* The lineal gain for the terminations is measured to the flue gas outlet height.
7
venting inStallation
Continued
There are two vent kits available which have been specially designed for common installations in manufactured (mobile) homes: MW8K
(8' vent kit) and MW9K (9' vent kit). Contents of these kits are listed under Accessories on page 18. IMPORTANT: If height of chimney assembly exceeds requirements for transportation of home, chimney installation may be completed after home is sited.
Note: Termination must always be installed after the home is sited.
ASSEMBLY AND INSTALLATION OF
DOUBLE WALL CHIMNEY SYSTEM
Each double wall chimney section consists of a galvanized outer pipe, a stainless steel inner flue pipe and a wire spacer. Pipe sections must be assembled independently as chimney is installed. When connecting chimney directly to fireplace, inner flue pipe section must be installed first with lanced side up. Outer pipe section can then be installed over flue pipe section with hemmed end up. Press down on each pipe section until lances securely engage hem on fireplace starter. Wire will assure proper spacing between inner and outer pipe sections.
WARNING: The opening in the collar around the chimney at the top of the fireplace must not be obstructed. Never use blown insulation to fill the chimney enclosure.
ADjUSTABLE FIRESTOP THIMBLE
(FST-A)
Adjustable Firestop Thimble Assembly (FST-
A) is used to provide necessary air space and clearance between chimney pipe and insulation in attic space of a manufactured home.
To install thimble assembly, determine distance between ceiling joist and roof framing.
Attach adjustable thimble to firestop spacer so that assembly will cover distance. Adjustable thimble should be even with or above roofline. Sheet metal screws or staples may be used to attach thimble to firestop spacer.
An opening large enough to allow insertion of firestop thimble assembly will be required in ceiling. Attach firestop/thimble assembly to ceiling/ceiling joist using screws or staples as shown in Figure 11. A minimum of 8 screws or staples should be used.
Firestop thimble assembly should also be used where there is a cathedral ceiling, insulation barrier and roof, all in one assembly in a manufactured home (see Figure 11).
The FST-A thimble can be used in any one of three common ceiling pitches; flat, 12"/96" and 30"/144".
An opening big enough to allow insertion of firestop thimble assembly will be required.
This opening depends on the pitch of your ceiling. If your ceiling is a flat or 12"/96" pitch, you must use adapter plate provided to seal unwanted openings. For 30"/144" pitch, discard adaptor.
Roof Line
Continue to assemble chimney sections as outlined above, making sure that both inner and outer pipe sections are locked together.
When installing double wall snap-lock chimney together, it is important to assure joint between chimney sections is locked. Check by pulling chimney upward after locking. Chimney will not come apart if properly locked. It is not necessary to add screws to keep chimney together
(exception, see Figure 16, page 11).
Thimble Extension
(If Needed)
Adjustable Thimble
Existing
Ceiling Frame
Firestop Spacer
Screws or Staples
(Min. of 8)
Figure 11 - Attaching Firestop/Thimble
Assembly to Ceiling
8 www.desatech.com
124558-01A
If adapter is needed, secure it onto firestop using holes provided (see Figure 12). The row of holes on sides of thimble is provided to allow for pitch variances. Position firestop
(top and bottom side) and thimble to desired angle and secure with screws provided. Insert thimble and firestop into prepared opening and secure to ceiling by nailing through firestop flanges. Thimble should be even with or above roofline. Thimble extensions are available (as an option) when required. See
Accessories on page 18. Firestop thimble is not required for modular home application.
Note: If there is a second story in the home, firestop spacer 3600FS-8DM will be required.
See Firestop Spacers, page 11.
Insulation
Barrier
Firestop
Adapter Plate (If Needed) venting inStallation
Continued
Thimble (Open End)
12"
Min.
Screw Holes
Provided for Thimble
Firestop
Thimble
(Closed End)
PENETRATING ROOF
To maintain a 1" clearance to pipe on a roof with a pitch, a rectangular opening must be cut.
1. Determine center point through which pipe will penetrate the roof.
2. Determine center point of the roof. Pitch is the distance the roof drops over a given span, usually 12". A 6/12 pitch means that the roof drops 6" for each 12" measured horizontally down from roof rafters.
3. Use roof opening chart (Figure 13) to determine correct opening length and flashing required.
4. Remove shingles around opening measured. Cut out this section.
5. Add next sections of pipe until end penetrates roof line. Check to see that proper clearances are maintained. Extend chimney by adding sections of double wall pipe until pipe is minimum of 30" above highest point of roof cutout. Termination and chimney must extend a minimum of
36" above highest point where it passes through roof.
Minimum Measurements
14 3 /
8
"
(36.5 cm)
1"
(2.5
cm)
30"
(76.2 cm)
1"
(2.5 cm)
Thimble
12"/96" Pitch
96"
7.13"
12"
30"/144" Pitch
11.77"
144"
30"
Adapter Plate
(For Flat and
12"/96" Pitch
Ceilings Only)
1"
(2.5
cm)
Opening "A"
Firestop
Use for Flat
Pitch Ceiling
Use for 12"/96"
Pitch Ceiling
Figure 12 - Use a Firestop Thimble
Assembly for Cathedral Ceiling,
Insulation Barrier and Roof
PITCH SLOPE
Flat 0°
0-6/12 26.6°
6/12 -
12/12
45°
OPENING
"A" MAx
16
15"
1 /
8
"
20 3 /
8
"
FLASHING
MODE NO.
6F-8
6F-8
12F-8
Figure 13 - Determine Roof Opening
124558-01A www.desatech.com
9
venting inStallation
Continued
USING ELBOW OFFSETS (30E-8DM)
1. To achieve desired offset, you may install combinations of 12", 18", 24", 36" and 48" length of double wall pipe (see offset chart and Figure 14).
OFFSET
74
76
79
1
3
3 /
/
/
RISE
4
" 137
4
" 141
4
" 146
1 /
1 /
3 /
2
2
4
"
"
" 1
CHIMNEY LENGTH
A
4 3 /
8
"
9 3 /
4
"
12 3 /
4
"
15"
18"
21
23
1
3
27 3 /
/
/
30"
33"
36"
38
41
1
1 /
/
45"
4
"
4
"
46 3 /
51"
4
"
53 1 /
4
"
4
"
4
"
4
"
B
16 3 /
8
" ELBOW SET ONLY
25 1 /
2
" 1
30 3 /
4
"
34 3 /
4
"
40"
46 1 /
4
49 1 /
4
56 3 /
4
"
"
"
60 3 /
4
"
66"
71"
75"
80 1 /
4
"
" 1 1
86 3 /
4
89 1 /
2
" 1 1
97"
101"
12" 18" 24" 36" 48"
1
1
1
1
1
1
1
1
56 1 /
59 1 /
4
4
" 106 1
" 111 1 /
/
4
2
"
"
1
61
64
3
3 /
/
68 1 /
70"
4
"
4
" 115 1 /
4
" 120 3 /
127"
4
2
" 1
"
130" 1
1
1
1
1
1
1
2
1
2
1
2
1
2
1
1
1
1
1
2
1
2
2
1
2
1
2 1
2 1
4
OFFSET CHART (22-50 FT. SYSTEM HEIGHT)
2. Chimney weight above offset rests on return elbow. Straps must be securely nailed to rafters or joists (see Figure 15, details A and B).
3. Maximum length of pipe between supports
(return elbow or 12S-8DM) is 6' of angle run. Maximum of two 6' angle run sections per chimney system (see Figure 14).
4. All pipe connections between offset and return must be secured with two screws on outer pipe only (see Figure 16). Do not penetrate inner stainless.
See
Detail A
Straps
Detail B
Straps
Angle Firestop
Straps
Straps
Detail A
Return Elbow
See Detail B
Figure 15 - Ceiling Support Pipe
12S-8DM
Screws
B
10
A
Figure 14 - Elbow Offset www.desatech.com
124558-01A
Offset
Elbow
Return
Elbow
Offset
Elbow
6' Max.
venting inStallation
Continued
Return
Elbow Offset
Elbow
Return
Elbow
6' Max.
Return
Elbow
Return
Elbow
Ceiling
Support Pipe
12S-8DM
6' Max.
6' Max.
Offset
Elbow 6' Max.
Offset
Elbow 6' Max.
A B C
Figure 16 - Typical Offset Terminations (For Systems with 2 Elbow Sets, Maximum
Height is 20')
FIRESTOP SPACERS (3600FS-8DM) Storm Collar
Firestop spacers are required at each point where the chimney penetrates a floor space.
Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials. When the pipe passes through a framed opening into a living space above, the firestop must be placed onto the ceiling from below as shown in Figure 17.
Flashing
Cone
Nail Only
Outer
Perimeter of Flashing
Overlap
Shingles Top and Sides Only
Existing
Ceiling
Frame
Firestop
Spacer
Screws or
Staples
(Min. of 8)
Figure 17 - Firestop Spacer with Living
Space Above Ceiling
FLASHING INSTALLATION (V6F-8DM
OR V12F-8DM)
Determine the flashing to be used with the roof opening chart. Slide flashing over pipe until base is flat against roof. Replace as many shingles as needed to cover exposed area and flashing base. Secure in position by nailing through shingles (see Figure 18). DO NOT
NAIL THROUGH FLASHING CONE.
Underlap Shingles at Bottom
Figure 18 - Flashing Installation
Installing Flashing on a Metal Roof
When installing flashing on a metal roof, it is required that putty tape be used between flashing and roof. Flashing must be secured to roof using #8 x 3/4" screws and then sealed with roof coating to prevent leakage through screw holes. A roof coating must also be applied around the perimeter of flashing to provide a proper seal.
124558-01A www.desatech.com
11
venting inStallation
Continued
Storm Collar Installation (SC1)
Place storm collar over pipe and slide down until it is snug against the open edge of flashing (see Figure 19). Use SC1 for all round terminations.
Attach
Bracket Tabs to Outer Pipe
(3 Places)
Secure with
Screws
Note: Storm collar is required but can be installed after the home is sited.
Terminations/Spark Arrestor
Chimney
Pipe
Waterproof
Caulk
Overlap
Shingles Top and Sides
Storm
Collar Flashing
RTL-8DM
Level of
Flue Gas
Outlet
Caulk
Storm
Collar
Flashing
Figure 19 - Storm Collar
Fireplace system must be terminated with listed round top termination. In any case, refer to installation instructions supplied with termination. Terminations approved for this fireplace are RT-8DM and RTL-8DM. Figure 20 shows an RTL-8DM round top termination.
IMPORTANT: Terminations are required but can be installed once the manufactured house is sited.
Underlap Shingles
Bottom Only
Figure 20 - Termination
CHASE INSTALLATIONS
Instructions for chase installations are included with chase style termination chosen. In a multiple chase installation, be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another. We suggest that terminations be separated at least 24", center to center and stacked at a vertical height difference of 18"
(see Figure 21).
CAUTION: Do not seal openings on the rooftop flashing. Follow the installation instructions provided with the termination being used.
Terminations with 16" slip pipe sections are available. The RTT-8DM and RTTL-8DM are approved for flashing installations. When needed, these adjustable terminations may be used in combination with the pipe assembly to achieve correct chimney height.
Note: In the rare instance there is a problem with side driven rain or wind, or the chimney is not drafting properly, an ADS-8DM Anti Draft
Shield can be used with round terminations.
24" Min.
24" Min.
18"
Min.
Typ.
Figure 21 - Multiple Chase Installation
12 www.desatech.com
124558-01A
10' venting inStallation
Continued
10 FOOT RULE
All flue gas outlet chimney terminations must extend a minimum of 3 feet in height above the highest point where it passes through the roof and must be at least 2 feet above the highest point of the roof that is within a horizontal distance of 10 feet (see Figure 22).
Level of
Flue Gas
Outlet
10' must not penetrate inner flue pipe). The angle of support wires should not be more than 45° from horizontal when fastened to roof. Place chimney support brackets approximately 18" below fireplace termination and space brackets approximately 120° apart (see Figure 23)
Follow instructions included in kit.
Self Drilling
Screws
Chimney
Support
Bracket
18"
2' Min.
3' Min.
2' Min.
3' Min.
Eye
Bolt
Figure 22 - 10 Foot Rule
CHIMNEY SUPPORT BRACKET KIT:
CSK-8DM
If exposed portion of chimney is greater than five feet above roofline, support wires are recommended to keep chimney secured.
Support wires must be attached to chimney support brackets. Chimney support brackets must be attached to outer pipe of chimney with self-drilling screws provided in kit (screws
Cable
Ferrule
Support
Wire
120°
Top
View of
Chimney
120°
Angle of Support
Wire Should Not
Be More Than 45°
From Horizontal
120°
Figure 23 - Support Wires oPtional gaS line inStallation
Permanently Located (Sited) Homes Only
Gas line hook up should be done by your supplier or a qualified service person.
Note: Before you proceed, make sure your gas supply is turned off.
A gas line may be installed for the purpose of installing a vented or vent free appliance available through your local distributor. Use only a 1/2" black iron pipe and appropriate fittings. When installing a gas line, a shutoff valve designed for installation outside appliance is recommended.
1. Remove knockout indentation on refractory or firebrick wall located above the refractory hearth floor. Knockout indentation must be firmly tapped with any solid object such as a 1/2" dowel until it is released.
Remove fragmented portions of refractory
(see Figure 24).
2. Remove gas line cover plate located on either side of fireplace and pull out insulation from gas line conduit sleeve. Save insulation for reuse. Replace screws.
Outside of
Fireplace
Gas Line
Conduit
Insulation
Knockout
Side
Firebrick
Finished
Side
1/2" Dowel
Gas
Conduit
Cover
Refractory
Knockout
Plug
Figure 24 - Gas Line Knockout
124558-01A www.desatech.com
13
venting inStallation
Continued
3. Run a 1/2" black iron gas line into fireplace through rear at gas line conduit sleeve
(if using a raised platform, add height).
Provide sufficient gas line into fireplace chamber for fitting connection (see Figure
25, page 14).
Note: Secure incoming gas line to wood framing to provide rigidity for threaded end.
4. Repack insulation around gas line and into sleeve opening. Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace cement, Install gas appliance or cap off gas line if desired.
CAUTION: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply soap and water solution to all connections and joints. Bubbles forming show a leak. Correct all leaks at once. DO NOT USE
AN OPEN FLAME FOR LEAK
TESTING AND DO NOT OPER-
ATE ANY APPLIANCE IF A LEAK
IS DETECTED. LEAK TESTING
SHOULD BE DONE BY A QUALI-
FIED SERVICE PERSON.
Outside of
Fireplace
Gas
Line
Conduit
Incoming
1/2" Black
Iron Pipe
Side
Firebrick
Finished
Side
Note: Secure incoming gas line to wood framing to provide rigidity for threaded end.
If you wish to install an unvented (ventfree) gas log set, ONLY UNVENTED GAS
LOG SETS WHICH HAVE BEEN FOUND
TO COMPLY WITH THE STANDARD FOR
UNVENTED ROOM HEATERS, ANSI
Z21.11.2, ARE TO BE INSTALLED IN THIS
FIREPLACE.
A vent-free log may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by locator.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
Note: A hood must be installed when using an vent-free gas log set (see Accessories, page 18).
WARNING: Do not operate an unvented gas log set in this fireplace with the chimney removed.
If you install a decorative gas appliance
(vented gas log), the decorative gas appliance must comply with the Standard for Decorative
Gas Appliance for Installation in Solid Fuel
Burning Fireplaces, ANS Z21.60, Z21.84 or
RG 2-72 and shall also be installed in accordance with the National Fuel Gas Code, ANSI
7223NFPA 54 latest edition.
WARNING: If the fireplace has been used for wood burning, the firebox and chimney must be cleaned of soot, creosote and ashes be a qualified chimney cleaner. Creosote will ignite if heavily heated.
Repack
Insulation
Seal
Opening with
Refractory
Cement
Provide Enough Threaded
End for Fitting Connection
Figure 25 - Gas Line Installation
WARNING: When using a decorative vented gas log, the damper must be removed or permanently locked in the fully open position and the glass doors must be in the fully open position.
14 www.desatech.com
124558-01A
FiniShing FirePlaCe
Combustible materials, such as wallboard, gypsum board, sheet rock, drywall, plywood, etc. may make direct contact with sides and top around the fireplace face. It is important that combustible materials do not overlap the face itself. Brick, glass, tile or other noncombustible materials may overlap the front face provided they do not obstruct essential openings like louvered slots or any other opening. When overlapping with a noncombustible facing material, use only noncombustible mortar or adhesive.
Note: HUD requirements may supersede these minimum dimensions.
12 1 /
4
" Ref.
Combustible
Material
6"
Ref.
33°
3" Nom.
Safe
Zone for
Projection of
Combustible
Materials
MANTELS
A mantel may be installed if desired (see
Figure 26). Woodwork such as wood trims, mantels or any other combustible material projecting from the front face must not be placed within 9" of the fireplace opening.
Combustible materials above 9" and projecting more than 1 1 /
2
" from the fireplace must not be placed less than 12" from the top opening of the fireplace (NFPA STD 211,
Sec. 7-3.3.3).
12"
Min.
1 1 /
2
" Max.
9" Min.
Upper
Section of
Fireplace
Fireplace
Opening
Figure 26 - Mantel Clearances to
Combustible Material oPeration and MaintenanCe guidelineS
GLASS DOORS
Glass doors are standard with fireplace.
When fireplace is in operation, doors must be FULLY OPENED or FULLY CLOSED position only or a fire hazard may be created
(see Figure 27).
A fireplace equipped glass doors operates much differently than a fireplace with an open front. A fireplace with glass doors has a limited amount of air for combustion. Excessive heat within fireplace can result if too large a fire is built or if combustion air gate is not completely open. The following tips should be followed to assure that both fireplace and glass door retain their beauty and function properly.
Both flue damper and glass doors must be fully opened before starting the fire. This will provide sufficient combustion air and maintain safe temperatures in firebox.
IMPORTANT: Glass must be allowed to warm slowly and evenly. Tempered glass will withstand a gradual temperature rise to 550°
Fahrenheit, which is more than a normal fire will generate.
Such materials as pitch/wax laden logs, very dry mill end lumber, and large amounts of paper or cardboard boxes can create an excessively hot fire and should not be burned in this fireplace. Always keep fire back from doors and never allow flames to contact glass.
WARNING: Fireplaces equipped with glass doors should be operated only with doors fully opened or fully closed. Doors, if left partly open, may draw gas and flame out of the fireplace opening creating risks of both fire and smoke.
Doors Fully Closed
Fireplace Front
Doors
Fully Opened
Fireplace Front
Figure 27 - Bi-Fold Glass Doors
124558-01A www.desatech.com
15
oPeration and MaintenanCe guidelineS
Continued
Door Removal
1. Fold doors (fully open) and press up on upper door spring clip until top pin is free of the spring clip (see Figure 28). Tip door toward middle of fireplace opening and lift door out of the lower pivot hole.
2. Repeat step 1 for remaining door.
Fold Door and Slide
Top Pins
Into Track
Figure 28 - Removing/Installing Bi-Fold
Doors
Installing Glass Doors
1. With bi-fold doors completely folded, insert bottom pivot pin into pivot hole located near bottom corner of front face opening and swing door to vertical position making sure top pins slide into door track. Door is installed when top door pin snaps into spring clip (see Figure 28).
2. Repeat step 1 for remaining door.
If you find the doors do not close properly or do not appear level or straight, proceed with section on door adjustment.
Door Adjustment
Remove doors and slightly loosen lower pivot clips and upper spring clips. Replace doors and fully close them. Use 1/8" shims (any material) to level doors. Once proper setting is achieved, carefully open doors enough so that you can access spring clips with a phillips screwdriver. Tighten screws. See Figure 29.
Spring
Clip
Insert Pin into Spring
Clip
Insert
Bottom
Pivot Pin into Hole
Pivot
Hole
Figure 29 - Adjusting Bi-Fold Doors
CLEANING GLASS
Clean the glass with any commercial glass cleaner or soap and water. Do not use any abrasive material to clean glass. Do not clean glass with any cool water if glass is still hot from fire and smoke.
DAMPER OPERATION
The damper handle, which opens and closes damper blade, is located inside firebox at center towards back wall. Pushing handle back in keyway slot will free damper blade to automatically open. To close, reach in and push handle back into keyhole slot then pull down and forward to lock it in place (see Figure 30).
Damper is not designed to be airtight. A small gap around damper blade is normal.
Damper
Weight
Closed Damper Open Damper
Figure 30 - Damper Operation
GRATE
Damper
Handle
WARNING: Risk of fire! Always replace grate with a model number 11116 grate only. This grate has been designed to keep the operation of your fireplace safe and efficient.
16 www.desatech.com
124558-01A
rePlaCeMent PartS
BI-FOLD GLASS DOORS
VDG36E - Brushed Finish
DP36E - Platinum Finish
VDBP36E - Black Finish
BRICK LINER
Rear - PN 20029
Left Side - PN 20030
Right Side - PN 20030
Front Bottom - PN 21242
Rear Bottom - PN 21241
DUAL FAN KIT - BK2
EMBER PROTECTOR - 20093
OPTIONAL OUTSIDE AIR KIT FOR
FLOOR INSTALLATION
90154 - Model AK6E
GRATE - 11116 teChniCal ServiCe
You may have further questions about installation, operation, or troubleshooting. If so, contact Style Crest at 1-800-231-4822 or write to: Style Crest Service, P. O. Box 19110,
Wichita, KS. 67204. When calling or writing, please have your model and serial numbers of your heater ready.
124558-01A www.desatech.com
17
aCCeSSorieS
DOUBLE WALL PIPE
18-8DM, 24-8DM, 36-8DM and 48-8DM
ROOF FLASHING
- 12-8DM,
V6F-8DM - 0 to 6/12 Pitch
V12F-8DM - 6/12 to 12/12 Pitch
ANTI-DRAFT SHIELD
(ROUND TOP TERMINATION ONLY)
ADS-8DM
FIRESTOP SPACER - V3600FS-8DM
CHIMNEY SUPPORT BRACKET KIT
CSK-8DM
Support Bracket
Self Drilling Screws
Cable Ferrule
Eye Bolt Screw
Strand Wire (50 ft)
12"/96" Pitch
96"
7.13"
30"/144" Pitch
11.77"
144"
12"
30"
30° OFFSET AND RETURN - 30E-8DM
ADjUSTABLE HOOD
GA6053 - Antique Brass Finish
GA6052 - Polished Brass Finish
GA6050 - Black Painted Finish
This hood is required when installing a ventfree gas log heater in this firebox.
ADjUSTABLE FIRESTOP THIMBLE
FST-A
Includes:
Thimble - PN 22383
Adapter Plate - PN 22398 (For Flat or
12/96 Pitch Ceilings Only)
Firestop - PN 22377
STORM COLLAR - SC1-1
18
ROUND TOP TERMINATION - RTL-8DM www.desatech.com
124558-01A
aCCeSSorieS
Continued
SQUARE CHASE-TOP
TERMINATION - ETL-8DM
OPTIONAL OUTSIDE AIR KIT FOR
SIDE WALL INSTALLATION - AK-6WE
HEARTH ExTENSION - 90192 AIR INLET HOOD - AK6-WI
AIR INLET HOOD (6 PACK) - MK6-WI
THIMBLE ExTENSIONS
TxL-8DM - 43" - PN 20745
Tx-8DM - 26" - PN 20746
FLEx DUCT 6" x 25" (3 PACK) - MP6-75
FACE ExTENSION - FE-36R
Front face extension would add 6” to the width and 6” to the height of the fireplace face.
VENT KIT*
36-8DM
24-8DM
18-8DM
FST-A
V6F-8DM
SC1-1
RTL-8DM
DESCRIPTION
36" Double Wall Pipe
24" Double Wall Pipe
18" Double Wall Pipe
Adjustable Firestop Thimble
Roof Flashing
Storm Collar
Round Cap Termination
MW8K
(8' Vent Kit)
2
1
0
1
1
1
1
*Use for Most Common Manufactured (Mobile) Home Installations
MW9K
(9' Vent Kit)
2
0
2
1
1
1
1
124558-01A www.desatech.com
19
This fireplace is manufactured for Stylecrest
Inc. under the VEXAR brand name by
DESA Heating, LLC
2701 Industrial Drive
Bowling Green, KY 42101 www.desatech.com
124558 01
NOT A UPC
124558-01
Rev. A
10/08