S1500 Series Pure Sine Wave Inverter User`s

Add to my manuals
40 Pages

advertisement

S1500 Series Pure Sine Wave Inverter User`s | Manualzz
S1500 Series
Pure Sine Wave Inverter
文管中心
User’s Manual
發行章
Contents
1.
2.
3.
Important safety striations…………………………………………………...
1-1
General safety precautions…………………………………………….
1
1-2
Precautions when working with batteries……………………………..
1
Features…………………………………………………………………………
2-1
Application……………………………………………………………….
2
2-2
Electrical performance………………………………………………….
3
2-3
Rear panel operations………………………………………………….
4
文管中心
Introduction…………………………………………………………………….
3-1
Front panel operations………………………………………………….
5~7
3-2
Rear panel operations…………………………………………………..
發行章
8~9
3-3
Installation………………………………………………………………..
9
3-4
Quick hook - up and testing…………………………………………..
10
3-5
AC safety grounding…………………………………………………….
11~12
3-6
Making DC wiring connections………………………………………...
13
3-7
Inverter operation………………………………………………………..
14~15
3-8
Power output…………………………………………………………….
16
4.
Troubleshooting guide……………………………………………………….
17
5.
Maintenance ……………………………………………………………………
18
6.
Warranty ………………………………………………………………………...
18
7.
Appendices A…………………………………………………………………..
8.
9.
7-1
Dip switch (110V)………………………………………………………..
19
7-2
Dip switch (220V)……………………………………………………….
19
Appendices B…………………………………………………………………..
8-1
Operations of RS232 serial port……………………………………….
20
8-2
Interface command……………………………………………………..
21~25
Appendices C…………………………………………………………………..
9-1
Remote control operations……………………………………………..
26~27
9-2
Power saving mode……………………………………………………..
28~31
Contents
10. Appendices…………………...………………………………………………...
10-1 FCC (Class B) declaration of conformity……………………………..
32
10-2 CE (EMC EN55022B) declaration of conformity…………………….
33
10-3 CE (LVD EN60950) declaration of conformity……………………….
34
10-4 e-mark (e13 020932) declaration of conformity……………………..
35
10-5 UL (UL458) declaration of conformity………………………………..
36
文管中心
發行章
1. Important Safety Instructions
WARNING!
Before using the Inverter, read and save the safety
instructions.
1-1. General Safety Precautions
1-1-1. Do not expose the Inverter to rain, snow, spray, bilge or dust.
To reduce risk of hazard, do not cover or obstruct the ventilation
openings. Do not install the Inverter in a zero-clearance compartment.
Overheating may result.
文管中心
1-1-2. To avoid a risk of fire and electronic shock. Make sure that existing
wiring is in good electrical condition; and that wire size is not
undersized.
Do not operate the Inverter with damaged or substandard Wiring.
發行章
1-1-3. This equipment contains components which can produce arcs or
sparks. To prevent fire or explosion do not install in compartments
containing batteries or Flammable materials or in locations which
require ignition protected equipment. This includes any space
containing gasoline-powered machinery, fuel tanks, or joints, fittings,
or other connection between components of the fuel system.
1-2. Precautions When Working with Batteries
1-2-1. If battery acid contacts skin or clothing, wash immediately with soap
and water. If acid enters eye, immediately flood eye with running
cold water for at least 20 minutes and get medical attention
immediately.
1-2-2. Never smoke or allow a spark or flame in vicinity of battery or Engine.
1-2-3. Do not drop a metal tool on the battery. The resulting spark or
short-circuit on the battery of other electrical part may cause an
explosion.
1-2-4. Remove personal metal items such as rings, bracelets, necklaces,
and watches when working with a lead-acid battery,
A lead-acid battery produces a short-circuit current high enough to
weld a ring or the like to metal, causing a severe burn.
1
2. Features
Pure sine wave output (THD < 3%)
Output frequency:50 / 60Hz switch selectable
Low power “Power Saving Mode” to conserve energy
RS - 232C interface / remote controls port
Built-in voltage and watt meter
Thermostatically controlled cooling fan
Advanced microprocessor
文管中心
Protection:Input low voltage
Low battery alarm
Overload
發行章
Input over voltage
Short circuit
Over temperature
2-1. Application
2-1-1. Power tools-circular saws, drills, grinders, sanders, buffers, weed and
hedge trimmers, air compressors.
2-1-2. Office equipment-computers, printers, monitors, facsimile machines,
scanner.
2-1-3. Household items-vacuum cleaners, fans, fluorescent and
incandescent lights, shavers, sewing machines.
2-1-4. Kitchen appliances-microwave ovens, refrigerators and freezers,
coffee makers, blenders, ice markers, toasters.
2-1-5. Industrial equipment-metal halide lamp, high-pressure sodium lamp.
2-1-6. Home entertainment electronics-television, VCRs, video games,
stereos, musical instruments, satellite equipment.
2
2-2. Electrical Performance
Specification
Model No.
Item
S1500-112 S1500-124 S1500-148 S1500-212 S1500-224 S1500-248
Continuous Output Power
1500W
Surge Rating
2000W
Input Voltage
Output Voltage
12V
24V
48V
100 / 110 / 115 / 120V +/- 5%
Frequency
Efficiency (full load)
No Load Current Draw
Output Waveform
Output Voltage Regulation
Input Voltage Regulation
Protection
24V
48V
200 / 220 / 230 / 240V +/- 3%
50 / 60Hz +/- 0.05%
(Switch Selectable)
Peak Output Current
12V
25A
文管中心
85%
87%
發行章
11A
88%
86%
89%
90%
≦1.5W Saving Mode
Sine Wave <3% THD
100 / 110 / 115 / 120V RMS
200 / 220 / 230 / 240V RMS
-10% / +4%
-10% / +4%
10-16
VDC
20-32
VDC
42-62
VDC
10-16
VDC
20-32
VDC
42-62
VDC
Overload, Short Circuit, Reverse Polarity (Fuse), Over/Under
Input Voltage, Over Temperature.
Power Saving Recovery
5 Second
Time
Interface Control Port
RS-232C With Baud Rate 1200,2400,4800 (Switch Selectable)
Remote Control Unit
CR-5 Optional
Safety
UL458
EMC
FCC Class B
EN60950
EN50081-1:1992
EN50082-1:1992
e-MARK
EN55022B:1994
EN61000-4-2:1995
e13-020932
EN61000-4-3:1996
ENV50204:1995
Operating Temperature Range
0 - 40℃
Storage Temperature Range
-30℃ to 70℃
Dimensions
390 (L) x 275 (W) x 105 (H) mm / 15.4 (L) x 10.8 (W) x 4.1 (H) Inch
Cooling
Thermostatically controlled cooling fan ( 55℃ ON , 45℃ OFF)
Weight
7.0kgs / 15.5 lbs.
3
2-3. Mechanical Drawings
文管中心
發行章
4
3. Introduction
This power inverter series is a the member of the most advanced line of mobile
AC power systems available.
To get the most out of the power inverter, it must be installed and used properly.
Please read the instructions in this manual before installing and using this model.
3-1. Front Panel Operations:
3-1-1. Front view:
文管中心
發行章
3-1-2. ON / OFF switch:
Power ON/OFF switch, leave in the OFF position during installation.
3-1-3. Battery Voltage indicator:
The battery voltage bar graph indicates the voltage at the input
terminals of the power inverter. At low input current, this voltage is
very close to the battery voltage. At high input current, this voltage
will be lower than the battery voltage because of the voltage drop
across the cable and connections. Ideally, the voltage should remain
in the green Ares of the bar graph. If the voltage goes into the red
area at top and bottom of the graph, inverter may shutdown.
5
3-1-4. Battery Voltage indicator:
The AC load watt bar graph indicates the power drawn from the power
inverter by the load. For long term operation, the watt indicator
should remind in the green & orange area of the bar graph.
Short term operation is possible with watt indicator in the red area.
If the watt indicator rises to high values the bar will flash and the
inverter will shutdown to protect itself.
3-1-5. OVP:Over Voltage indicator:
The over voltage indicator indicates that the power inverter has shut
itself down because its input voltage exceeded 12 / 24 / 48VDC
version.
文管中心
3-1-6. UVP:Under Voltage Protection indicator:
發行章
The under voltage indicator indicates that the power inverter has shut
itself down because its input voltage fell below 12 / 24 / 48VDC.
3-1-7. OTP:Over Temperature Protection indicator:
The over temp indicator indicates that the power inverter has shut itself
down because its temp has become overheated. The power inverter
may overheat because it has been operated at power levels above its
rating, or because it has been installed in a location which does not
allow it to dissipate heat properly. The power inverter will restart
automatically, once it has cooled off.
3-1-8. OLP:Over Load Protection indicator:
The overload indicator indicates that the power inverter has shut itself
down because its output has been short circuited or drastically
overloaded.
Switch the ON/OFF switch to OFF, correct the fault condition, and then
switch the ON/OFF switch back to ON to reset the unit.
3-1-9. Power Saving:Power energy saving enable.
See appendix 9-2 for detailed information.
6
3-1-10. AC Outlet (Outlet sockets available):
North America (GFCI)
North America (NEMA 5-15R)
Continental European (SCHUKO)
Australia / New Zealand
文管中心
發行章
United Kingdom
Universal
7
3-2. Rear Panel Operations:
文管中心
3-2-1. Ventilation Openings:
Do not obstruct, allow at least 3 inch for air flow.
發行章
3-2-2. DC Terminals:
Connect to 12V / 24 V / 48V battery or the other power sources.
【+】is positive, 【-】is negative. Reverse polarity connection will
blow internal fuse and may damage inverter permanently.
Model voltage
S1500-112
S1500-212
S1500-124
S1500-224
S1500-148
S1500-248
Min voltage
Max. voltage
10.0 VDC
16.0 VDC
20.0 VDC
32.0 VDC
42.0 VDC
62.0 VDC
WARNING!
Do not connect the 12V model to a 24 battery,
The unit will be destroyed immediately.
8
3-2-3. RS-232C:
Connect to remote control unit (option accessory) or taken remote
controlled working status by computer.
3-2-4. Connect chassis ground terminal to earth or to vehicle chassis using
#8 AWG wire.
WARNING!
Operation of the inverter without a proper ground
connection may result in an electrical safety hazard.
文管中心
3-3. Protection Feature
發行章
DC Input
Model
Restart
Under
Voltage
Alarm
16.7VDC 15.2VDC
Over voltage
Shutdown
Under Voltage
Shutdown
Restart
10.2VDC
9.5VDC
12.6VDC
S1500-124
33.4VDC 30.4VDC
S1500-224
20.4VDC
19.0VDC 25.2VDC
S1500-148
63.0VDC 60.8VDC
S1500-248
41.6VDC
42.0VDC 50.4VDC
S1500-112
Over
Temperature
Protection
ShutRestart
down
S1500-212
85℃
45℃
9
3-4. Installation:
Where to install. The power inverter should be installed in a location that
meets the following requirements:
3-4-1. Dry - Do not allow water to drip or splash on the inverter.
3-4-2. Cool - Ambient air temperature should be between 0°C
3-4-3. Safe - Do not install in a battery compartment or other areas where
flammable fumes may exist, such as fuel storage areas or engine
compartments.
文管中心
3-4-4. Ventilated - Allow at least three inch of clearance around the inverter
for air flow. Ensure the ventilation openings on the rear and front of
the unit are not obstructed.
發行章
3-4-5. Dust-free - Do not install the Inverter in a dusty environments where
are dust, wood particles or other filings/shavings.
These dust can be pulled into the unit when the cooling fan is
operating.
3-4-6. Close to batteries - Avoid excessive cable lengths but do not install
the Inverter in the same compartment as batteries.
Use the recommended wire lengths and sizes (see section 2-10).
Also do not mount the Inverter where it will be exposed to the gases
produced by the battery.
These gases are very corrosive and prolonged exposure will damage
the Inverter.
WARNING!
You may observe a spark when you make this
connection since current may flow to charge
capacitors in the power inverter.
Do not make this connection in the presence of
Flammable fumes. Explosion or fire may result.
10
3-5. Making DC Wiring Connections:
Follow this procedure to connect the battery cables to the DC input terminals
of the Inverter. Your cables should be as short as possible ( ideally, less
than 6 feet / 1.8 meters ) enough to handle the required current in accordance
with the electrical codes or regulations application. Cables are not an
adequate gauge ( too narrow ) or too long will decrease the inverter
performances such as poor surge capability and low input voltage warnings
frequently and shutdowns. UVP warning presents due to DC voltage drop
across the cables from the inverter to the batteries.
The longer or narrower the cables, the greater the voltage drop.
Increasing your DC cable size will help improve the situation.
Model No
S1500-112
S1500-212
文管中心
Wire AWG
#2
發行章
#2
Inline Fuse
200A
200A
S1500-124
#4
130A
S1500-224
#4
130A
S1500-148
#6
50A
S1500-248
#6
50A
WARNING!
The installation of a fuse must be on positive cable.
Failure to place a fuse on “+” cables running between
the inverter and battery may cause damage to the
inverter and will void warranty.
11
Also, use only high quality copper wiring and keep cable length short, a
maximum of 3-6 feet.
S1500
文管中心
發行章
IN L IN E F U S E
-
+
BATTERY
12
3-6. AC Safety Grounding:
During the AC wiring installation, AC input and output ground wires are
connected to the inverter. The AC input ground wire must connect to the
incoming ground from your AC utility source.
The AC output ground wire should go to the grounding point for your loads
( for example, a distribution panel ground bus ).
Ground Fault Circuit Interrupters (GFCI):
Installations in Recreational Vehicles ( for North American approvals ) will
require GFCI protection of all branch circuit connected to the AC output of the
hardwire terminal equipped Inverter. In addition, electrical codes require
GFCI protection of certain receptacles in residential installations.
While the pure sine wave output of the Inverter is equivalent to the wave form
provided by utilities, compliance with UL standards requires us to test and
recommend specific GFCI.
Cotek has tested the following GFCI - protected 20A receptacles and found
that they functioned properly when connected to the output of the Inverter.
文管中心
發行章
3-6-1. Neutral Grounding (GFCI’S):
3-6-1-1. 120V models:The neutral conductor of the AC output circuit
of the Inverter is automatically connected to the safety ground
during inverter operation. This conforms to national
electrical code requirements that separately derived AC
sources (such as inverter and generators) have their neutral
conductors tied to ground in the same way that the neutral
conductor from the utility is tied to ground at the AC breaker
panel. For models configured with a transfer relay, while AC
utility power is presenting and the Inverter is in bypass mode,
this connection (neutral of the Inverter’s AC output to input
safety ground) is not present so that the utility neutral is only
connected to ground at your breaker panel, as required.
3-6-1-2. 230V models:There is no connection made inside the
Inverter from either the line or neutral conductor to the safety
ground.
13
3-7. Inverter Operation:
To operate the power inverter, turn it on by using the ON/OFF switch on the
front panel. The power inverter is now ready to deliver AC power to your
loads. If you are operating several loads from the power inverter, turn them
on separately after the inverter has been turned on.
This will ensure that the power inverter does not have to deliver the starting
currents for all the loads at once.
3-7-1. Unpack and inspect the power inverter, check to see that the power
switch in the OFF position.
文管中心
3-7-2. Connect the cables to the power input terminals on the year panel of
power inverter.
The terminal is positive (+) and black terminal is negative (-).
Insert the cables into the terminals and tighten allen nut to clamp the
wires securely.
發行章
WARNING!
Make sure all the DC connections are tight (torque to
9-10 ft-lbs, 11.7-13Nm). Loose connections will
overheat and could result in a potential hazard.
3-7-3. Before proceeding further, carefully check that cable you have just
connected does tie negative terminal of inverter to the negative output
power source.
WARNING!
Reverse polarity connection will blow a fuse in inverter
and may permanently damage the inverter.
Damage caused by reverse polarity connection is not
covered by warranty.
3-7-4. Connect the cable from the negative terminal of the inverter to the
negative terminal of the power source. Make a secure connection.
14
WARNING!
You may observe a spark when you make this
connection since current may flow to charge
capacitors in the power inverter.
Do not make this connection in the presence of
flammable fumes Explosion or fire may result.
3-7-5. Set the power switch to the ON position. Check the meters and
indicators on the front panel of the inverter. The voltage bar graph
should indicate 11 to 14 volts (22 to 28V when 24V version is used)
depending on the voltage of the power source. If does not, check
your power source and the connections to inverter.
The other indicators should be off.
文管中心
發行章
3-7-6. Set power inverter switch to the OFF position, the indicator lights may
blink and the internal alarm may sound momentarily.
The is normal. Plug the test load into the AC receptacle on the front
panel of the inverter. Leave the test load switch off.
3-7-7. Set power inverter switch to the ON position and turn the test load On.
The inverter should supply power to the load.
If you plan to accurately measure the true output r.m.s. voltage of
inverter, a meter such as FLUKE 45 BECKMAN 4410 or TRIPLETT
200 must be used.
15
3-8. Power output:
The inverter will operate most AC loads within its power rating.
When deeming whether a microwave oven can be operated by the inverter,
remember that the power commonly advertised for microwave ovens are the
cooking power (the power delivered to the food) not the power actually
consumed by the microwave oven. The microwave oven will consume 40%
to 100% more than its advertised cooking power. Check the rating sticker
on the back of the oven to determine its actual power requirements.
The 1500W inverter will operate small microwave oven (0.2 to 0.3 cubic foot
capacity) that draws about 1700 watts. It will provide 3 minutes of cooking
time. Some induction motors used in refrigerators, freezers, pumps, and
other motor operated equipment require very high surge currents to start.
The Power Inverter may not be able to start some of these motor even though
their rated current requirement is within the power inverter.
If motor is refused to start, observe the battery voltage indicator while trying to
start the motor. If the battery voltage indicator drops below 11 volts while
inverter is attempting to start the motor, this may be why the motor won’t start.
Make sure that the battery connections are good and the battery is fully
charged.
文管中心
發行章
16
4. Troubleshooting guide:
WARNING!
Do not open or disassemble the Inverter.
Attempting to service the unit yourself may result in a risk of
electrical shock or fire.
Problems and Symptoms Possible Cause
Solutions
Low output voltage
Using average reading Use true RMS reading meter
and cable.
voltmeter
See page 15
Point 3-7-7. of manual
Load LED bar flash.
Overload
Reduce load.
文管中心
發行章
No output voltage.
And voltage indicator
in lower red zone.
No output voltage.
Over Temp indicator
on, load less than
1500W.
Low input voltage.
No output voltage,
Over Load indicator
On.
Short circuit or Wiring
error.
Thermal shutdown
Very high power load
Recharge battery,
check connections
and cable.
Improve ventilation,
Make sure ventilation
openings in inverter
are not obstructed.
Reduce ambient
temperature.
Check AC wiring
for short circuit or
improper polarity (hot
and neutral reversed).
Remove load
17
5. Maintenance:
Very little maintenance is required to keep your inverter operating properly.
You should clean the exterior of the unit periodically with a damp cloth to prevent
accumulation of dust and dirt.
At the same time, tighten the screws on the DC input terminals.
6. Warranty:
We warrant this product against defects in materials and workmanship for a period
of 24 months from the date of purchase and will repair or replace any defective
Power Inverter when directly returned, postage paid, to us.
This warranty will be considered void if the unit has suffered any obvious physical
damage or alteration either internally or externally and does not cover damage
arising from improper use such as plugging.
The unit into an unsuitable power sources attempts to operate products with
excessive power consumption requirements, or use in unsuitable environments.
This is the only warranty that the company makes.
No other warranties express or imply including warranties of merchantability and
fitness for a particular purpose.
Repair and replacement are your sole remedies and the company shall not be
liable for damages, whether direct, incidental, special or consequential, even
though caused by negligence or other fault.
文管中心
發行章
18
7. Appendix A
7-1. Dip Switch (110V)
S1
S2
VOUT
(VAC)
S3
FREQ.
(Hz)
S5
S6
BAUD
RATE
ON
ON
100
ON
50
ON
ON
1200
OFF
ON
110
OF
60
OFF
ON
2400
ON
OFF
115
------
------
ON
OFF
4800
OFF
OFF
120
----------文管中心
OFF
OFF
4800
7-2. Dip Switch (220V)
發行章
S1
S2
VOUT
(VAC)
S3
FREQ.
(Hz)
S5
S6
BAUD
RATE
ON
ON
200
ON
50
ON
ON
1200
OFF
ON
220
OF
60
OFF
ON
2400
ON
OFF
230
------
------
ON
OFF
4800
OFF
OFF
240
------
------
OFF
OFF
4800
※S4 is unavailable
19
8. Appendix B
8-1. Operations of RS232 Serial Port
8-1-1. Hardware design:
This unit uses a 9-pin D connector and three of RS232 signal lines:
RECEIVE DATA (RXD):PIN2
TRANSMIT DATA (TXD): PIN3
DATA TERMINAL READY (DTR):PIN4
文管中心
8-1-2. The connection between this unit and a computer is as follows:
Computer
發行章
Power Inverter
RXD
RXD
TXD
TXD
DSR
DTR
RTS
CTS
GND
GND
8-1-3. The RS232 interface of this unit employs ASCll code to implement the
asynchronous serial transmission control.
The byte structure is START BIP – 8 BIT DATA-STOP BIT Baud
rate:1200,2400,4800,(SET BY DIP-SW).
Parity check :NONE, not settable
Data bit:8, not settable.
Stop bit:1, not settable.
20
8-2. Interface Command:
The buffer size used for the RS232 port is 12-bytes. This unit will ignore all
bytes more than this value.
During transmission, this unit (inverter) will indicate it is ready to receive data
from computer by the DTR line. A computer has to check the DTR line
before sending any information to this unit.
This unit is normally always ready to receive data while operating.
When a LF character (ASCll code 0AH) is received, this unit would finish the
receiving by clearing the DTR status and begin to interpret the received
information. The unit would execute the received command (AND/OR data)
if it is correct.
Irrespective of whether the command is accepted or not, the unit will always
send back a response signal to the computer and set DTR to ready for
receiving more incoming information.
文管中心
發行章
8-2-1. The Baud Rate of the RS232 interface is determined by S5 and S6 of
DIP-SW, as shows in Appendix A.
Note:You have to reset the unit after adjustment to activate the New
settings.
8-2-2. Illustration of the RS232 operation:
8-2-2-1. RS232 command
Command format:
This unit uses high-level language commands with a CR (0DH)
and a LF (0AH) as the end of the command.
The system would interpret and execute the command only
after these two characters are received.
After the unit execute the command, it would send a response
string to the computer.
The response string is as follows:
= > CR LF:Command executed successfully
? > CR LF:Command error, not accepted
! > CR LF:Command correct but execution error (e.g.
parameters out of range)
If the command needs any information from the unit, the unit
would send the information back to the computer (with CR
and LF) and then send the response string to the computer.
21
8-2-2-2. Command format
This unit supports the following commands.
There should always be a CR (0DH) and a LF (0AH)
appended to the command while sending the command to his
unit.
8-2-2-3. PWRS command:
Power saving function control
Format: PWRS < value>
Illustration:A space (ASCll code 20H) is needed between
PWRS and < value >
< value > can be one of the following
“0”:Power saving disable
“1”:Power saving enable
“2”:Inquire the status of saving the response information
would be either “0” (disable) or “1” (enable)
文管中心
發行章
8-2-2-4. Power command
Power ON/OFF control
Format:Power < value>
Illustration:A space (ASCll code 20H) is needed between
PWRS and < value >
< value > can be one of the following
“0”:Power off, power consumption < 2W, restart time < 5 sec
“1”:Power off, power consumption <20W, restart time < 2
sec
“2”:Power on
“3”:Inquire the status of power on/off status, the response
information would be either “0” (OFF) or “1” (OFF) or “2”
(ON)
22
8-2-2-5. To query status command
Format:STUS?
Illustration:Don’t need to add any of parameter.
To respond the result be hexadecimal code replaced by 2
ASCll codes that is between 00 ~ FF (0~255), then convert
the Hex code to the binary digit after obtaining 8 bytes digit
that can be one of following:
“B0” UVP ( LSB )
“B1” OVP
“B2” OLP ( Loading > 110% )
文管中心
“B3” FLP ( Loading > 100% / 3min )
“B4” OTP
“B5” BATT Too Low
發行章
“B6” BATT Too High
“B7” BATT Too High ( MSB)
23
8-2-2-6. To query battery level command
Format:BATT?
Illustration:Don’t need to add any of parameter.
To respond the result be Hexadecimal code replaced by 2
ASCll codes and is between 00 ~ 0B, then convert into
decade digit after obtaining a digit, between 0 ~ 11, that can
be one of following :
Hex Decade
code code
24
Indication
00
0
LED 1 glows blinking to indicate low voltage
01
1
02
2
LED 2 glows solid.
03
3
LED 3 glows solid.
發行章
04
4
LED 4 glows solid.
05
5
LED 5 glows solid.
06
6
LED 6 glows solid.
07
7
LED 7 glows solid.
08
8
LED 8 glows solid.
09
9
LED 9 glows solid.
0A
10
LED 10 glows solid.
0B
11
LED 10 glows blinking to indicate over voltage
LED 1 glows solid.
文管中心
8-2-2-7. To query load level command:
Format:Load?
Illustration:Don’t need adding any of parameter.
Respond:The same as BATT?
< value > can be one of following
Hex Decade
code code
Indication
00
0
Load < 5%, All of LED indicators go “OFF”
01
1
Load < 15%, LED 1 indicator glows.
02
2
03
3
Load < 35%, LED 1~LED 3 indicators glow.
發行章
04
4
Load < 45%, LED 1~LED 4 indicators glow.
05
5
Load < 55%, LED 1~LED 5 indicators glow.
06
6
Load < 65%, LED 1~LED 6 indicators glow.
07
7
Load < 75%, LED 1~LED 7 indicators glow.
08
8
Load < 85%, LED 1~LED 5 indicators glow.
09
9
Load < 95%, LED 1~LED 5 indicators glow.
0A
10
Load < 105%, LED 1~LED 10 indicators glow.
0B
11
Load > 105%, All of LED indicators glow
blinking to indicate over load.
文管中心
Load < 25%, LED 1~LED 2 indicators glow.
25
9. Appendix C
9-1. Remote Control Operations:( Optional accessory )
System Configuration:
9-1-1. Plug the 9-pin D-SUB connector of the remote controller in the RS-232
port of the Inverter.
9-1-2. Check the setting of DIP-SW S5 & S6, The communication BAUD
RATE should be set to 4800bps (S5 & S6 OFF).
LED Indications:
文管中心
9-1-3. Turn on the switch of the Inverter, There will be two short beep sounds
from the Inverter. All LEDS will be ON and, one second later, there
will be a short Beep sound. The amber, green and red LEDS of
remote controller will be on for 0.5 second then off sequentially. The
Inverter is then in the OFF mode.
The amber LED will be blinking every 2~3 seconds.
發行章
9-1-3-1. Remote Controller LEDS:
Color / Status
Power Saving
Power Output
Green ”ON”
Enable
ON
Green “Blinking”
Enable
OFF
Amber “ON”
Enable
ON
Amber “Blinking”
Enable
OFF
Green:Power saving enable.1
Amber:Power saving disable.
On:Power On
Blinking:Power Off
26
Operations:
9-1-4. Set SLIDE SW “ON” (Keypads will not work if SLIDE SW is set “OFF”)
9-1-5. Remote ON/OFF:Pressing a button (and releasing in one second) will
change (toggle) the output ON/OFF mode and the display of LEDS will
be changed accordingly.
9-1-6. Operations of power saving mode:
Press the button for 2 seconds and the colors of LED will be changed.
Keep pressing the button and the colors will be toggling between
amber and green every 2~3 seconds.
The color of LED will determine the mode of operation.
Green indicates that power saving mode is enabled and amber
indicates is disabled.
Release the button when the LED indicating the desired status is
reached.
文管中心
發行章
9-1-7. The operation power saving enable / disable does not change the
power ON/OFF mode.
9-1-8. Despite the setting of power saving mode, when a power OFF
command is set by pressing a button, the power will be turned OFF
and the power saving mode will be set to disable automatically (amber
LED will flash for 2~3 seconds). When the power is turned On, the
power saving mode will restore the previous setting.
27
9-2. Power saving mode
MICROPROCESSOR BASED SINE WAVE INVERTER S-1500 SERIES
ENABLING AND DISABLING POWER SAVING MODE
9-2-1. When an inverter is powered on and is running in idle condition ( there
is no load or the load connected to the inverter has been switched off ),
it will still draw some power from the batteries for keeping the system
alive.
9-2-2. This inverter features a power saving “sleep” mode for conserving the
battery power during idle conditions. When this mode is enabled,
the inverter senses the output power being drawn and if this is less
than 2 to 15 watts, the inverter shuts down the output power. Only
essential systems are kept alive to reduce power consumption from
the batteries to a very low value of only about 1.5 watts. As soon as
a load is switched on, the inverter wakes up from its “sleep” condition
and restores the output power after a response time of about 8
seconds. Please note that on waking up from the power saving
“sleep” mode, the inverter requires some time to prepare all the
systems before it can start delivering power to the load. Hence, the
output power will not be available immediately but after a time lag of
approx. 15 to 18 sec. If using a hand tool or other appliance with a
trigger, keep the trigger pressed for some time till the power is
available to drive the tool / appliance.
文管中心
發行章
9-2-3. The power saving “sleep” mode can be enabled or disabled with the
help of the power on / off switch or with the help of the optional remote
control. Procedure to switch between the two states is given at para
6 below. The inverter has been factory pre-set in the enabled
condition.
9-2-4. Power saving “sleep” mode, enabled
9-2-4-1. The front plate has a green led marked “power saving” for
indication of enabled state of power saving “sleep” mode
(here-in-after referred to as the green led)
28
9-2-4-2. The power saving “sleep” mode is enabled in either of the
following indications ( When inverter is in on condition ):
The green led flashing sequence is:
Flash-flash-gap-flash-flash-gap…….( power saving “sleep”
mode, idle condition or no load )
The green led is continuously lighted ( power saving “sleep”
mode, loaded )
9-2-5. Following indications will be observed when the inverter is powered on
and subsequently loaded and unloaded when power saving “sleep”
mode is in enabled condition:( the initial condition is that the inverter
is switch ed off and all loads are disconnected )
文管中心
9-2-5-1. Switch on the inverter. There will be 2 beeps and the green
led will start flashing with a flashing sequence of flash-flashflash……After about 3 seconds, there will be 1 beep, the
green led will stop flashing and it will be lighted continuously.
Output power will be available after about 15 to 18 sec from
the time the green led stops flashing. After the output power
is made available, the inverter searches if any load is
connected. If the load is less than 2 to 15 watts, the output
power is shut down after about 15 seconds from the time the
output power is made available.
The green led will start a flashing sequence of flash-flashgap-flash-Flash-gap…..( this indicates that the inverter is in
power saving “sleep” mode and is idling at no load )
發行章
9-2-5-2. If now a load more than 2 to 15 watts is switch ed on, the
green led stops flashing after about 3 seconds and will be
lighted continuously. After about 15 to 18 seconds after the
green led has stopped flashing and become steady, output
power will be available to the load. The green led will be
lighted continuously ( this indicates that the inverter is in
power saving “sleep” mode and is in loaded condition )
9-2-5-3. If the load is switched off, the output power will be shut down
after about 15 to 18 seconds and the green led will start
flashing with a flashing sequence of flash-flash-gap-flashflash-gap……( this indicates that the inverter is in power
saving “sleep” mode and is idling at no load )
29
9-2-6. Power saving “sleep” mode, disabled
9-2-6-1. The front plate has a green led marked “power saving” for
indication of enable state of power save “sleep” mode ( herein-after referred to as the green led )
9-2-6-2. The power saving “sleep” mode is disabled when the green
led marked “power saving” is off. In this mode the output
power is always available.
9-2-6-3. Following indications will be observed when the inverter is
powered on and subsequently loaded and unloaded when
power saving “sleep” mode is in disabled condition:( the
initial condition is that the inverter is switched off and all loads
are disconnected )
文管中心
發行章
9-2-6-3-1. Switch on the inverter. There will be 2 beeps and
green led will start flashing with a flashing
sequence of flash-flash-flash…..After about 3
seconds, there will be 1 beep and the green led
will stop flashing and switch off. Output power
will be available after about 15 to 18 sec from the
time the green led switches off. The output
power will be always available, even in no load
idling condition.
The green led will be off all the time.
9-2-7. Switching between enabled and disabled states of power saving
“sleep” mode
9-2-7-1. Switching between enabled and disabled states of power
saving “sleep” mode can be done with the help of the power
on / off switch on the front plate of the inverter or with the help
of the optional remote control.
Switch on the front plate of the inverter is done as follows:
30
Switch on the front plate of the inverter is done as follows:
This procedure acts as a toggle i.e. If the inverter was in
enabled state before the procedure, it will switch to disabled
state after the procedure.
Likewise, if it was in disabled state before the procedure, it will
switch to enabled state after the procedure.
Switch off all the loads, switch off the inverter, disconnect all
loads. Switch on the inverter. There will be 2 beeps and
green led will start flashing with a flashing sequence of flashflash-flash…..( it will flash for approx. 3 seconds ).
Immediately after it starts flashing, switch off the power on /
off switch and immediately switch on again. This will
complete the switching procedure. The inverter will continue
its power on sequence and switch over to the new state.
文管中心
The power on / off switch should be switched off and on again
during the time the green led is flashing ( the green led will
flash with a sequence of flash-flash-flash…..For about 3
seconds after the inverter is powered on )
發行章
31
10-1. FCC ( class B ) Declaration of Conformity
文管中心
發行章
32
10-2. CE ( EMC EN55022B ) Declaration of Conformity
文管中心
發行章
33
10-3. CE ( LVD EN60950 ) Declaration OF Conformity
文管中心
發行章
34
10-4. e-mark ( e13 020932 ) Declaration of Conformity
文管中心
發行章
35
10-5. UL ( UL458 ) Declaration of Conformity
文管中心
發行章
36
文管中心
發行章
No. 33, Rong Shin Rd., Pa Te City, Tao Yuan County, Taiwan
Phone: 886-3-3661581 FAX: 886-3-3676029
E-mail: [email protected] http: // www.cotek.com.tw
2006.05 A-R