ChoiceMMed America Co BP10 Owner's Manual

Add to My manuals
24 Pages

advertisement

ChoiceMMed America Co BP10 Owner's Manual | Manualzz

Owner's Manual

Arm-type Fully Automatic

Digital Blood Pressure Monitor

Model:BP10

Ver 1.0

Distributed by:

ChoiceMMed America Co.

2558 Peal Buck Road, Suite 8A

Bristol, PA 19007

Contents

Safety Notice ..........................................................................................1

Unit Illustration ......................................................................................3

Important Testing Guidelines ...............................................................6

Quick Start .............................................................................................7

Unit Operation ........................................................................................8

Blood Pressure Information ..............................................................14

Blood Pressure Q & A .........................................................................16

Maintenance .........................................................................................17

Specifications .....................................................................................19

Warranty ...............................................................................................21

Digital Blood Pressure Monitor BP10

Safety Notice

i

Thank you for purchasing the BP10 Blood Pressure Monitor. The unit has been constructed using reliable circuitry and durable materials. Used properly, this unit will provide yeas of satisfactory use.

This device is intended for non-invasive measuring an adult individuals’ systolic, diastolic blood pressure and heart rate using the oscillometric method. The device is not intended for use on infants and children. The device is designed for home or clinical use. All values can be read out in one LCD DISPLAY. Measurement position s o n a d u l t u p p e r a r m o n l y .

P l e a s e r e a d t h i s m a n u a l t h o r o u g h l y b e f o r e u s i n g t h e u n ti .

blood pressure, please

CONSULT YOUR DOCTOR.

To avoid risk and damage follow all warning precautions. Operate unit only as intended.Read all instructions prior to use.

Blood pressure measurement determined with this device are equivalent to those obtained by a trained observer using the cuff/ stethoscope auscultation method, within the limits prescribed by the American National Standard (ANSI/AAMI SP10) for electronic Sphygmomanometers.

WARNING SIGNS AND SYMBOLS USED

Date of manufacturer

Caution

Type BF Equipment

SN Serial Number

Storage temperature and relative humidity

Consult Instructions For Use

Safety Notice

1. Individuals with serious circulation problems may experience discomfort. Consult your physician prior to use.

- 1 -

BP10 Digital Blood Pressure Monitor

2. Contact your physician if test results regularly indicate abnormal readings. Do not attempt to self-treat these symptoms without consulting your physician first.

3. Product is designed for its intended use only. Do not misuse in any way.

4. If you are taking medication, consult with your physician to determine the most appropriate time to measure your blood pressure. NEVER change a prescribed medication without first consulting with your physician.

5. People suffering from vascular constriction, liver disorders or diabetes, people with cardiac pacemakers or a weak pulse, and women who are pregnant should consult their physician before measuring their blood pressure themselves. Different values may be obtained due to their condition.

6. For persons with irregular or unstable circulation resulting from diabetes, liver disease, arteriosclerosis or other medical conditions, there may be variations in blood pressure values measured at the wrist versus at the upper arm. Monitoring the trends in your blood pressure taken at either the arm or the wrist is nevertheless useful and important.

7. People suffering from arrhythmias such as atrial or ventricular premature beats or atrial fibrillation only use this blood pressure monitor in consultation with your doctor.

In certain cases oscillometric measurement method can produce incorrect readings.

8. Product is not intended for infants or individuals who cannot express their intentions.

9. Do not disassemble or attempt to repair.

10. Do not use cell phones and other devices, which generate strong electrical or electromagnetic fields, near the device, as they may cause incorrect readings and interference or become interference source to the device.

11. Any hazards associated with prolonged overinflation of the bladder.

12. Only use a recommended AC adaptor complying with EN 60601-1 and EN 60601-

1-2(see page 6). An unauthorized adaptor may cause fire and electric shock.

Battery Precautions

Do not mix new and old batteries simultaneously.

Replace batteries when Low Battery Indicator “ “ appears on screen.

Be sure battery polarity is correct.

Do not mix battery types. Long-life alkaline batteries are recommended.

Remove batteries from device when not in operation for more than 3 months.

Dispose batteries properly; observe local laws and regulations.

- 2 -

Digital Blood Pressure Monitor

Unit Illustration

Monitor Unit

BP10

- 3 -

BP10

Arm Cuff

Digital Blood Pressure Monitor

Display

- 4 -

Digital Blood Pressure Monitor

Contents

BP10

- 5 -

BP10 Digital Blood Pressure Monitor

Important Testing Guidelines

1. Avoid eating, exercising, and bathing for 30 minutes prior to testing.

2. Sit in a calm environment for at least 5 minutes prior to testing.

3. Do not stand while testing. Sit in a relaxed position while keeping your arm level with your heart.

4. Avoid speaking or moving body parts while testing.

5. While testing, avoid strong electromagnetic interference such as microwave ovens and cell phones.

6. Wait 3 minutes or longer before re-testing.

7. Try to measure your blood pressure at the same time each day for consistency.

8. Test comparisons should only be made when monitor is used on the same arm, in the same position, and at the same time of day.

9. This blood pressure monitor is not recommended for people with severe arrhythmia.

Any blood pressure recording can be affected by the following factors:

1. The position of the subject, his or her physiologic condition;

2. The performance and accuracy of the device;

3. Cuff size: too small cuff (bladder) will produce a higher blood pressure value than usual, too big cuff (bladder) will produce a lower blood pressure value;

4. Measuring position does not keep level with your heart;

5. Speaking or moving body parts while testing;

6. Not relaxing for about 5 minutes before taking the measurement.

- 6 -

Digital Blood Pressure Monitor

Quick Start

1. Install batteries. (See Figure A )

2. Insert cuff air plug into the left side of monitor unit. (See Figure B)

BP10

3. Remove thick clothing from the arm area.

4. Rest for several minutes prior to testing. Sit down in a quiet place, preferably at a desk or table, with your arm resting on a firm surface and your feet flat on the floor.

(See Figure C )

5. Apply cuff to your left arm and keep level with your heart. Bottom of cuff should be placed approximately 1-2cm (0.4-0.8’’) above elbow joint. (See Figures D&E)

6. Press “START/STOP” Button to start testing.

- 7 -

BP10 Digital Blood Pressure Monitor

Unit Operation

Battery Installation

Slide battery cover off as indicated by arrow.

Install 4 new AA alkaline batteries according to polarity.

Close battery cover.

AC Adapter jack is on the right side of the monitor. Medical AC adapter(DC 6.0 V,

600mA) can be used with the device (recommended, not provided). The adapter connect pin should be positive inside and negative outside with a 2.1mm coaxial joint.

Do not use any other type of AC adaptor as it may harm the unit.

Time/Date Setting

With power off, press “START/STOP”button about 3 seconds to set the Time/Date mode.Set month first by adjusting the “MEM” butten, Press “STOP/START ”button setting the day, hour, and minute in same fashion.

Which in any setting mode..Press“START/ STOP”button to turn the unit off..All information will be saved.

- 8 -

Digital Blood Pressure Monitor BP10

Note: if unit is left on and not in use for 3 minutes, it will automatically save all information and shut of .

Applying the Arm Cuff

1. Firmly insert air plug into opening located on left side of monitor unit.

2. With sticky nylon section facing outward, insert end of cuff underneath metal ring of cuff

3. Fasten cuff about 1-2cm (0.4-0.8’’) above the elbow joint..For best results apply cuff to bare arm and keep level with heart while testing.

Note: Do not insert air plug into opening located on right side of monitor unit.

This opening is designed for an optional power supply only.

Testing

1. Power On

Press and hold “ START/STOP “ button until a beep sounds. The LCD screen will

- 9 -

BP10 Digital Blood Pressure Monitor appear for one second as unit performs a quick diagnosis. A long tone indicates device is ready for testing.

Note: Unit will not function if residual air from previous testing is present in cuff.

The LCD will flash “ “ until pressure is stabilized. .

2. Pressurization

Initial pressure is first pumped to 190 mmHg. If the current user’s systolic blood pressure is over 190mmHg, the unit will automatically re-inflate to the proper shelf.

Note: Pressurization will gradually subside and ultimately stop when cuff is not properly applied to the arm. If this occurs, press “ START/STOP ”button to turm the unit off.

3. Testing

After cuff inflation, air will slowly subside as indicated by the corresponding cuff pressure value. A flashing “ “ will appear simultaneously on screen signaling heart beat detection.

- 10 -

Digital Blood Pressure Monitor BP10

Note: Keep relaxed during testing. Avoid speaking or moving body parts.

4. Result Display

Three short beeps sound when testing is complete. The screen will display measurements for systolic and diastolic blood pressure.

Note: Refer to Page 17 for detail Blood Pressure Information.

Power Off

The “ START/ STOP” button can be pressed to turn off the unit in any mode. The unit can turn off the power itself about 3 minutes no operation in any mode.

Safety Precaution: If pressure in arm cuff becomes too extreme while testing, press the “ START/STOP “ button to turn power off. The cuff pressure will rapidly dissipate once the unit is off.

Memory Check

With power off, press and hold “ MEM ” butten to turn the unit on. The LCD will display the last measurement memory as NO:1 reading . Older test result in memiry can be viewed by pressing the “MEM” butten.

- 11 -

BP10 Digital Blood Pressure Monitor

Memory Deletion

Which in memory check made. Press " START/ STOP" and hold on for about 3 seconds to delete all history results and the LCD screen display“- - -” with beep sounds:Then press " START/ STOP" button to turn off the unit..

Note: Memory cannot be recovered once it has been deleted.

Low Battery Indicator

4 short warning beeps sound when battery life is depleting and unable to inflate cuff for testing. The “ “ appears simultaneously for approximately 5 seconds prior to shutting off. Replace batteries at this time. No memory loss will occur throughout this process.

- 12 -

Digital Blood Pressure Monitor

Troubleshooting

Problem

Blood pressure results are not within typical range

BP10

Possible Cause Solution

Cuff is too tight or not properly positioned on the arm

Inaccurate test results due to body movement or monitor movement

Firmly reposition cuff approximately1-2cm1/2” ( 1/2”) above the elbow joint ( See Page 11)

Sit in a relaxed position with arm placed near heart.. Avoid speaking or moving body parts while testing.

Make sure the monitor unit is placed in a stationary position throughout the testing period.( See Page 8)

" "displayed Improper operation

Pressurization is over

300mmHg

Read user manual carefully and retest properly.

Read user manual carefully and retest properly.

- 13 -

BP10 Digital Blood Pressure Monitor

Blood Pressure Information

Blood Pressure

Blood pressure is the force of blood pushing against the walls of arteries. It is typically measured in millimeters of mercury (mmHg.) Systolic blood pressure is the maximumforce exerted against blood vessel walls each time the heart beats. Diastolic blood pressure is the force exerted on blood vessels when the heart is resting between beats.

An individual’s blood pressure frequently changes throughout the course of a day.

Excitement and tension can cause blood pressure to rise, while drinking alcohol and bathing can lower blood pressure. Certain hormones like adrenaline (which your body releases under stress) can cause blood vessels to constrict, leading to a rise in blood pressure.

If these measuring numbers become too high, it means the heart is working harder than it should.

Health Reminder

Hypertension is a dangerous disease that can affect the quality of life. It can lead to a lot of problems including heart failure, kidney failure, and cerebral hemorrhaging. By maintaining a healthy lifestyle and visiting your physician on a regular basis, hypertension and relative diseases are much easier to control when diagnosed in their early stages.

- 14 -

Digital Blood Pressure Monitor BP10

Note: Do not be alarmed if an abnormal reading occurs. A better indication of an individual’s blood pressure occurs after 2-3 readings are taken at the same time each day over an extended period of time. Consult your physican if test results remain abnormal.

- 15 -

BP10 Digital Blood Pressure Monitor

Blood Pressure Q & A

Q: What is the difference between measuring blood pressure at home or at a professional healthcare clinic?

A: Blood pressure readings taken at home are now seen to give a more accurate account as they better reflect your daily life. Readings can be elevated when taken in a clinical or medical environment. This is known as White Coat Hypertension and may be caused by feeling anxious or nervous.

Note: Abnormal test results may be caused by:

1. Improper cuff placement

Make sure cuff is snug-not too tight or too loose.

Make sure bottom of the cuff is approximately 1-2cm (1/2’’) above the elbow joint.

2. Improper body position

Make sure to keep your body in an upright position.

3. Feeling anxious or nervous

Take 2-3 deep breaths, wait a few minutes and resume testing.

Q: What causes different readings?

A: Blood pressure varies throughout the course of a day. Many factors including diet, stress, cuff placement, etc. may affect an individual’s blood pressure.

Q: Should I apply the cuff to the left or right arm? What is the difference?

A: Either arm can be used when testing, however, when comparing results, the same arm should be used. Testing on your left arm may provide more accurate results as it is located closer to your heart.

Q: What is the best time of day for testing?

A: Morning time or any time you feel relaxed and stress free.

- 16 -

Digital Blood Pressure Monitor

Maintenance

1. Avoid dropping, slamming, or throwing the unit.

BP10

2. Avoid extreme temperatures. Do not expose unit directly under sunshine.

3. When cleaning the unit, use a soft fabric and lightly wipe with mild detergent. Use a damp cloth to remove dirt and excess detergent.

- 17 -

BP10 Digital Blood Pressure Monitor

4. Cuff Cleaning: Do not soak cuff in water! Apply a small amount of rubbing alcohol to a soft cloth to clean cuff’s surface. Use a damp cloth (water-based) to wipe clean.

Allow cuff to dry naturally at room temperature.

5. Do not use petrol, thinners or similar solvents.

6. Remove batteries when not in operation for an extended period of time.

7. Do not disassemble product.

8. It is recommended the performance should be checked every 2 years.

9. Expected service life: Approximately three years at 10 tests per day.

- 18 -

Digital Blood Pressure Monitor

Specifications

BP10

Product Description Arm-type Fully Automatic Digital Blood Pressure Monitor

Model

Display

Measurement Method

Measurement Range

Measurement Accuracy

Pressurization

Memory

Function

Power Source

Battery Life

Unit Weight

Unit Dimensions

Cuff Circumference

Operating Environment

Bp10

LCD Digital Display Size: 62.7mm×46.4mm (2.47” x

1.83”)

Oscillometric Method

Pressure 0mmHg~300mmHg

Pulse

Pressure

Pulse

30 to 180 Beats/Minute

±3mmHg

±5%

Automatic Pressurization

120 Memories

Low Battery Detection

Automatic Power-Off

4 AA batteries or Medical AC Adapter(DC6.0V,

600mA)

(recommended, not provided)

Approximately 2 months at 3 tests per day

Approx.405g (14.30 oz.) (excluding battery)

Approx.134 x 99 x 66mm (5.27” x 3.92” x 2.61” )(L x

W x H)

Approx.135 (W)×485(L) mm

(Medium cuff: Fits arm circumference 22-36 cm)

Temperature 10℃ ~ 40℃ (50 ℉ ~104 ℉ )

Humidity

Pressure

15%-90% RH

Atmospheric Pressure

- 19 -

BP10 Digital Blood Pressure Monitor

Storage Environment

Temperature:

Humidity

-20℃ ~55℃ (-4 ℉ ~131 ℉ )

15%-90% RH

Pressure 525mmHg~795mmHg

Internal Powered Equipment, Type BF ,Cuff is the Applied

Part

This Blood Pressure Monitor complies with the European regulations and bears the

CE mark “CE 0123”.This blood pressure monitor also complies with mainly following standards (included but not limited):

Safety standard:

EN 60601-1 Medical electrical equipment part 1: General requirements for safety

EMC standard:

EN 60601-1-2 Medical electrical equipment part 1-2: General requirements for safety- Collateral standard: Electromagnetic compatibility- Requirements and tests

Performance standards:

EN 1060-1 Non-invasive sphygmomanometers - General requirements

EN 1060-3 Non-invasive sphygmomanometers - Supplementary requirements for electromechanical blood pressure measuring systems.

EN 1060-4 Non-invasive sphygmomanometers - Test procedures to determine the overall system accuracy of automated non-invasive sphygmomanometers.

Correct Disposal of This Product

Discard the used product to the recycling collection point according to local regulations.

Warranty

To obtain full warranty coverage, please be sure to complete your product registration. If you choose not to register your product, this Limited Warranty will be void.

ONLINE:

- Go to www.choicemmedamerica.com/register

- Fill out required information

MAIL:

- Complete the Warranty Registration Card

- Include a COPY of your sales receipt

- Send to: 2558 Pearl Buck Rd, Suite 8A, Bristol, PA 19007

- 20 -

Digital Blood Pressure Monitor

Warranty Registration Card

Model No. LOT#

SN No.

BP10

Purchase Name:

E-Mail:

Phone:

Address 1:

Purchase Date:

Address 2 :

City/State : Zip:

Warranty Conditions

ChoiceMMed America Co. warrants to the original purchaser that this equipment will be free from defects in materials and workmanship for a period of two years from the date of purchase. This warranty shall be limited to the repair adjustment and/or replacement at the manufacturer’s option of defective parts free of charge except the cost of transportation to ChoiceMMed America Co. Manufacturer’s responsibility is limited to actual cost of item. When returning equipment for warranty service, all shipping and insurance charges must be prepaid and the proof of purchase must be enclosed. A payment of $10.00 must be included to cover the return shipping and handling. Returns will only be shipped to locations within the USA. ChoiceMMed

America Co. will not be responsible for expenses or inconveniences, or consequential damages occasioned by equipment or by breach of any expressed or implied warranty with respect thereto.

Limitations

This warranty covers all defects encountered in normal use of the equipment and does not apply in the following cases.

1. If the equipment has been serviced by other than a certified center.

2. Damage to the equipment due to mishandling, abuse, accident or failure to follow the operating instructions.

3. INSTRUMENTS: Warranty does not extend to display face, batteries and carrying case.

Customer Service Representatives are available

Monday through Friday - 9:30am to 4:30pm EST

Service Phone: (215)-874-0458 www.choicemmedamerica.com

- 21 -

Distributed by:

ChoiceMMed America Co.

2558 Pearl Buck Road, Suite 8A

Bristol, PA 19007

© 2014 ChoiceMMed America Co.

Revised Date: November 24, 2014

advertisement

Related manuals

advertisement