Coleman 8fa3 Instructions for use
Add to My manuals12 Pages
Coleman 2200 is a mosquito repellent that uses heat, carbon dioxide, and a special mosquito attractant called Octenol to lure mosquitoes to it, where they can be captured. It also emits and circulates a patented scent that inhibits mosquitoes' ability to detect humans.
advertisement
Instructions for use
Patent Nos. 5,205,064; 5,799,436;
6,055,766; D466578; D468389
U.S. and other Patents Pending
© 2002 The Coleman Company, Inc.
www.coleman.com
IMPORTANT
Read this manual carefully before assembling, using or servicing this unit. Keep this manual for future reference. If you have questions about assembly, operation, servicing or repair, please call Coleman at 1-800-835-3278 or TDD:
316-832-8707.
For Outdoor use only
Propane Tank & Battery
Not Included
EPA Est. No.: 69269-KS-1
EPA Reg. No.: 70909-3-69269 (Octenol)
EPA Reg. No.: 70909-2-69269 (Linalool)
Contents
Introduction
General Safety Information
System Description
Assembly
Leak Check
Operation
Moving Unit
Placement
Helpful Hints
Storage
Maintenance
Troubleshooting
Service
Mosquito Deleto TM Refills
Replacement Parts
Guarantees
Warranty
10
10
11
12
12
9
9
8
8 & 9
9
10
6
7
2
2 & 3
3
4 - 7
Introduction
•
Mosquito Deleto TM System
•
No zapping
•
No lotions
•
No sprays
•
No electrical cords
•
Mosquitoes have highly developed senses for detecting humans and animals.
Mosquitoes are attracted to three things:
• carbon dioxide from breath
• body heat
• faint odors emitted by animals and humans.
•
The Mosquito Deleto TM Trap lures mosquitoes to it by emitting heat, carbon dioxide and a special mosquito attractant called
Octenol. The Mosquito Deleto TM Inhibitor emits and circulates a patented scent that inhibits mosquitoes’ ability to detect humans.
•
The irresistible combination attracts mosquitoes to the trap where they are captured. . .never to bother you again!
•
This instruction manual will assist you in setting up your new
Mosquito Deleto TM System. Please refer to the instructions included with the Inhibitor for details on use, storage, specifications.
2
General Safety Information
This manual contains important information about the assembly, operation and maintenance of this product and system. General safety information is presented in these first few pages and is also located throughout the manual. Particular attention should be paid to information accompanied by the safety alert symbols: “ DANGER”, “ WARNING”, “ CAUTION”.
Keep this manual for future reference and to educate new users of this product. This manual should be read in conjunction with the labeling on the product.
Safety precautions are essential when any mechanical or propane fueled equipment is involved. These precautions are necessary when using, storing, and servicing. Using this equipment with the respect and caution demanded will reduce the possibilities of personal injury or property damage.
The following symbols shown below are used extensively throughout this manual. Always heed these precautions, as they are essential when using any mechanical or fueled equipment.
DANGER
DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
General Safety Information
cont.
WARNING
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate personal injury, or property damage.
WARNING: For Outdoor Use Only
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read the instructions thoroughly before installing or servicing this equipment.
DANGER
Failure to comply with the precautions and instructions provided with this mosquito trap can result in death, serious bodily injury and property loss or damage from hazards of fire, explosion, burn, asphyxiation, and/or carbon monoxide poisoning.
Only persons who can understand and follow the instructions should use or service this mosquito trap.
If you need assistance or information such as an instruction manual or labels, contact The Coleman Co., Inc.
WARNING
• This product is fueled by propane gas. Propane gas is invisible, odorless, and flammable. An odorant is normally added to help detect leaks and can be described as a “rotten egg” smell. The odorant can fade over time so leaking gas is not always detectable by smell alone.
• Propane gas is heavier than air and leaking propane will sink to the lowest level possible. It can be ignited by ignition sources including matches, lighters, sparks or open flames of any kind many feet away from the original leak. Use only propane gas set up for vapor withdrawal.
• Propane gas should be stored or used in compliance with local ordinances and codes or with ANSI/NFPA 58. Turn off propane when not in use.
• The propane tank must always be stored outdoors in a well-ventilated space. Never store propane tank in an enclosed area (house, garage, etc.). If unit is to be stored indoors, disconnect the propane tank for outdoor storage.
WARNING
Combustion by-products produced when using this product contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
General Safety Information
cont.
DANGER
• CARBON MONOXIDE HAZARD
• This unit is a combustion appliance. All combustion appliances produce carbon monoxide (CO) during the combustion process.
This product is designed to produce extremely minute, non-hazardous amounts of CO if used and maintained in accordance with all warnings and instructions.
• Carbon Monoxide (CO) poisoning produces flu-like symptoms, watery eyes, headaches, dizziness, fatigue and possibly death.
You can’t see it and you can’t smell it. It’s an invisible killer. If these symptoms are present during operation of this product get fresh air immediately!
• For outdoor use only.
• Never use inside house, or other unventilated or enclosed areas. This unit consumes air (oxygen). Do not use in unventilated or enclosed areas to avoid endangering your life.
WARNING
CAUTION
• SERVICE SAFETY
• Keep all connections and fittings clean. Make sure propane tank valve outlet is clean.
• Inspect hose before use. Replace if there is evidence of abrasion or wear.
• During setup, check all connections and fittings for leaks using soapy water. Never use a flame.
• Use for mosquito control only. Never alter in any way or use with any device or part not expressly approved by Coleman.
• You must provide propane gas and propane tank. Use a standard 20 lb. propane tank.
• Use this mosquito trap only with a propane vapor withdrawal supply system. See Chapter 5 of the Standard for Storage and Handling of
Liquefied Petroleum Gas, ANSI/NFPA 58. Your local library or fire department will have this book.
• The hose assembly installed with the mosquito trap must be used.
• The installation must conform with local codes,
Standard 20 lb. tank or in the absence of local codes, with National
Fuel Gas Code, ANSI Z223.1.
• A dented, rusted or damaged propane tank may be hazardous and should be checked by your tank supplier. Never use a propane tank with a damaged valve connection.
• The propane tank must be constructed and marked in accordance with the specifications for LP gas cylinders of the U.S. Department of
Transportation (DOT).
• BURN HAZARD
• Unit is hot when being used. Use care when servicing.
• Keep out of reach of children.
System Description
Quick Tips
Sheet
Wheels
Head
Assembly
Mosquito Deleto TM
Inhibitor
Axle
Bushings Base
Tank
Cover
Stakes
Consumables
Bag
Feet
Hardware
Collar
Tank
Retainer
Legs
Front Bar
Axle
3
4
Assembly
Step 1
TOOLS REQUIRED & OTHER ITEMS: (not provided)
• Standard Phillips head screwdriver • 20# propane cylinder
• 7/16" end wrench
• Lightweight hammer
• One (1) AAA battery
■ Remove all components from the package.
■ See package label for listing of contents for the model you purchased.
Step 3
■ Insert Axle through one
Wheel and then insert
Axle through Axle
Bushings.(Make sure side of tire with recessed area on hub is to the outside.)
■ Insert Axle through second wheel & cap both ends with Retainer
Nuts.
■ To properly seat
Retainer Nuts, gently tap with a hammer & support the bottom of Axle.
Mosquito
Deleto TM
Inhibitor
Refill
(Linalool)
Adhesive
Trap
Mosquito
Deleto TM
Octenol
Lure
Refill
Stakes
Step 2
■ With a lightweight hammer, tap Axle Bushings into Base. Make sure
Bushings are fully seated.
Step 4
(Actual size)
■ Set both feet on base.
Axle
Bushing
Base
■ Axle Bushings will receive the
Axle for the Wheels.
■ Install front bar in feet.
■ Assemble feet to base using hardware illustrated.
Assembly
cont.
Step 5
■ Turn the Base over.
■ Install legs to base. All Legs are identical.
■ Do not install screws until Step 7.
Step 7
cont.
(Actual size)
■ Install Tank Retainer at Leg position opposite the Handle Grip.
Step 6
■ Turn Head Assembly over while holding Lid closed.
■ Attach Collar to Head Assembly.
■ Align ribs on Collar with Ignitor.
■ Install Carriage Bolts, Washers, Nuts.
Tank
Retainer
■ Install screws and tighten.
(Actual size)
Step 7
■ Turn Head Assembly over while holding lid closed.
■ Set Head Assembly on legs with
Handle positioned as shown.
Ignitor
Ribs on
Collar
■ Install Retaining Screws at bottom of Legs.
(Actual size)
■ Tighten Retaining Screws and
Nut on the Tank Retainer.
■ Unit is now prepared for tank installation.
Handle
Grip
5
Assembly
cont.
Step 9
■ Install Tank Cover.
Step 11
■ Attach hose to tank.
■ Set tank in unit with open side of Tank Ring facing front of
Mosquito Deleto.
Open side of
Tank
Ring
Step 10
■ Set Tank Retainer on ring of
Propane Tank.
■ Tighten thumb screw securely.
Leak Check
WARNING
• Perform leak test outdoors.
• Extinguish all open flames.
• NEVER leak test when smoking.
• Do not use the mosquito trap until connection has been leak tested and does not leak.
• Make 2-3 oz. of leak check solution (one part liquid dishwashing detergent and three parts water).
• Apply several drops of solution at Hose/Cylinder Connection.
• Turn Cylinder Valve ON.
If bubbles appear at connection, there is a leak.
• Turn Cylinder Valve OFF.
• Disconnect, reconnect, and perform another leak check. If you continue to see bubbles after several attempts, cylinder valve or hose is defective and should be replaced. Defective cylinders should be returned to cylinder’s place of purchase.
If NO bubbles appear at connection, the connection is secure.
• Turn Cylinder Valve OFF.
Hose/Cylinder
Connection
Cylinder Valve
NOTE: Whenever gas connection is loosened or removed, you must perform a leak test.
CAUTION
Do not tamper with the regulator or use any substitute regulator.
Step 12
■ Unscrew Ignitor Button.
■ Insert one (1) AAA battery then replace Ignitor Button and tighten.
IMPORTANT: Make sure positive (+) end of battery is facing towards the front of the unit as shown.
6
IMPORTANT: Be sure Tank Retainer is secure before moving the unit.
Positive (+) end of battery to the front
Assembly
cont.
Step 13
CAUTION
Contents of octenol cartridge are harmful if swallowed. Wash hands before eating, drinking, chewing gum, using tobacco or using bathroom facilities. Avoid contact with inside surface of foil package.
■ Remove Mosquito Deleto
TM octenol lure refill from foil package.
■ Install lure into unit with holes facing center of trap.
Step 15
■ Unit may be secured by driving stakes through holes in feet.
Operation
DANGER
• CARBON MONOXIDE HAZARD
• For outdoor use only. Never use inside house, or other unventilated or enclosed areas. This unit consumes air (oxygen). Do not use in unventilated or enclosed areas to avoid endangering your life.
DANGER
Step 14
■ Remove the waxed paper from the adhesive trap.
■ Install one adhesive trap into back of unit and one adhesive trap into front of unit.
Note: Adhesive surface must face toward outside.
Helpful Tip:
On hot days, the waxed paper will remove easily if the adhesive trays are cool. Store traps indoors.
■ Photos below show detail of adhesive trap sliding over tray rails (typical both edges).
• EXPLOSION - FIRE HAZARD
• Never store propane near high heat, open flames, pilot lights, direct sunlight, other ignition sources or where temperatures exceed 120 degrees F (49°C).
• Propane is heavier than air and can accumulate in low places. If you smell gas, leave the area immediately.
• Never install or remove propane tank while unit is operating, near flame, pilot lights, other ignition sources or while unit is hot to touch.
• This unit is hot during use and can ignite flammables. Keep gasoline and other flammable liquids and vapors well away from unit.
• The propane tank must always be stored outdoors in a well-ventilated space. Never store propane tank in an enclosed area (house, garage, etc.). If unit is to be stored indoors, disconnect the propane tank for outdoor storage.
• Do not attempt to operate until you have read & understand all General
Safety Information in this manual, all assembly is complete and leak checks have been performed.
• After lighting the unit for the first time it is normal to see some smoke coming from the burner area. This smoke is the result of the burning of residual oils from the manufacturing process. The smoke will disappear within 10-15 minutes.
To Turn On
CAUTION
Unit cannot be match lit. Do not attempt.
■ Slowly open Tank Valve.
■ Allow system to fill for approximately 60 seconds.
■ Press and hold Red Ignitor Button.
■ Ignition should occur within 30 seconds and will be indicated by thermometer movement.
7
8
To Turn On
cont.
■ Verify ignition by observing gauge:
Start Up 3-5 minutes (Normal)
Unit operating properly when needle in green zone
If the needle enters the red zone (HOT) on the gauge, immediately turn off the unit
& call Coleman at
1-800-835-3278.
CAUTION
To Turn Off
■ Turn cylinder valve OFF.
To Move Unit
■ Unit can be moved from location to location by using the handle on the unit as shown.
■ Allow to cool for approximately
45 minutes before replacing lure or adhesive trap.
Approximate
Consumable Usage
• Propane: 40 days.
• Octenol Lure Refill: 1 month.
• Adhesive Trap: Approximately
2 weeks or when full.
■ Repeat this process each time you restart of the unit.
Proper Inhibitor and Trap Placement
1. Placement of the trap – find an area of your yard that is shaded, cool, or well protected by brush. Refer to the Quick
Tips Sheet.
2. Mosquitoes breed in standing water or areas that become flooded with water during rain storms. Mosquitoes will also take cover under low lying brush to stay cool on warm days.
3. The trap should be placed in an area away from where people gather. We recommend a distance of at least 50 feet away from people.
4. Positioning of the device is very important. If you are not catching mosquitoes, move the unit to another area of the yard that is protected from wind and direct sun and is near water. Try each location for a minimum of 2 days.
5. The Trap is designed to operate around the clock in your yard. The Trap continuously attracts, traps, and kills mosquitoes all day and all night.
6. Together, the Mosquito Deleto TM Inhibitor and Trap are a strong defense against mosquitoes!
7. Place the inhibitor unit per instructions in the inhibitor package.
Proper Inhibitor and Trap Placement
cont.
How To Use Mosquito Deleto
TM
Products
:
1. Use the Mosquito Deleto TM Inhibitor to push mosquitoes away from you. . .use the Mosquito Deleto TM Trap to attract and kill mosquitoes!
2. The Mosquito Deleto TM Inhibitor is designed for occasional use. Turn it on when going outdoors to gently disperse the scent that blocks the mosquitoes’ sensors. Turning the unit off will close the vents and preserve the unit for future use.
3. The Mosquito Deleto TM Inhibitor unit should be placed near where people gather. If there is a gentle breeze, be sure to place the inhibitor upwind from where people gather to be sure the scent covers the area desired.
4. During days of gusty winds (over 20 miles an hour), you should recheck the Mosquito Deleto TM Trap to be sure that the trap burner has not blown out.
Helpful Hints
1. Did you know that only female mosquitoes bite? Female mosquitoes need protein to breed and lay eggs.
2. Mosquito eggs need water to hatch. Stopping adult female mosquitoes from breeding will help to reduce your problem with mosquitoes.
3. Mosquitoes can also be good fliers. While most mosquitoes do not migrate far from where they breed, some mosquitoes can fly up to 75 miles.
4. Mosquitoes also bite primarily in the evening and morning hours, when it is cooler. Some types of mosquitoes bite during the day. All mosquitoes like the temperature to be warm and generally humid, but not hot. During very hot days, mosquitoes will hide in the brush to stay cool.
5. Mosquitoes will also take cover from winds greater than
10 miles an hour.
6. Clearing your yard of standing water will help to reduce the number of mosquitoes breeding in your area. Remove all standing water in buckets, tires, and plant trays. Make sure that areas in your yard do not become flooded with standing water. All ponds and bird baths should have water cleaned frequently or water should be circulated to prevent mosquitoes from breeding.
Storage
Disconnect mosquito trap from propane tank before long-term storage of either the cylinder or the mosquito trap.
1. Turn cylinder valve off.
2. Disconnect hose from cylinder.
3. Separate tank from unit.
4. Remove AAA battery from Ignitor.
5. Store propane tank in safe manner. Refer to Chapter 5 of Standard
for Storage and Handling of Liquefied Gases, ANSI/NFPA 58. Follow all local codes. Always store propane tanks outdoors.
6. Place mosquito trap in plastic bag or sealed box.
7. Store mosquito trap and base in a dry, clean, and safe place.
WARNING
• BURN HAZARD
• Do not touch or attempt any maintenance on unit for at least one hour after use.
• Make sure propane tank has been removed before doing maintenance.
Maintenance
To enjoy years of outstanding performance from your mosquito trap perform the following maintenance activities on a regular basis:
• Keep exterior surfaces clean.
• Use warm soapy water for cleaning. Never use flammable or corrosive cleaning agents.
• While cleaning your unit, be sure to keep the area around the burner dry at all times.
• Air flow must be unobstructed. Keep controls, burner, and circulating air passages clean. Signs of possible blockage include:
- Gas odor.
- Mosquito trap makes popping noises.
- Smoky exhaust.
• It is a good practice to remove leaves or trash that may collect in or near the cage.
• Spiders and insects can nest in unit. This condition can cause malfunctions. When trap is not in use, store in plastic bag or sealed box.
(See Storage Instructions.) Compressed air may help clear away small particles.
• If unit has been left uncovered and is wet from rain, yard sprinklers, etc., allow to dry (at least 30 minutes prior to use).
• In a salt-air environment (such as near an ocean), corrosion occurs more quickly than normal. Frequently check for corroded areas and clean or repair them promptly.
9
Troubleshooting
Problem
Burner won’t light
Burner won’t stay lit
Adhesive Panels dripping
Possible Cause
Cylinder valve is closed
Gas pressure is low
Air in gas line
Solution
Open valve
Turn Cylinder valve OFF and replace cylinder
Burner may take 20 seconds to light after a propane bottle has been connected
Cylinder is empty. Replace cylinder Low gas pressure with Cylinder Valve fully open
Igniter fails Replace AAA Battery
Improper purging of new 20 lb. cylinder Attach cylinder to other appliance (Grill) to purge air from line.
Gas pressure is low Turn Cylinder valve OFF and replace cylinder
Outdoor temperature is less than 40° F Use a full cylinder and tank is less than 1/4 full
Supply hose is bent or kinked Straighten hose
Panels exposed to direct sunlight Move out of direct sunlight. If desired, replace.
Service
• Repair to gas passages and associated components should be done only by a qualified service person.
• Owner repair & service should be limited and performed only to the following:
- Octenol Lure replacement
- Adhesive Trap replacement
- Cylinder replacement
- Listed parts replacement (See Replacement Parts List)
- Routine Cleaning
Mosquito Deleto
TM
Refills
Mosquito Deleto TM
Octenol Lure Refill
Model # 2960-601
Mosquito Deleto TM Inhibitor
Model # 2950-603
Mosquito Deleto TM
Trap Cartridge Refill
Model # 2960-602
Mosquito Deleto TM
System Refill
Model # 2950-700
Mosquito Deleto TM
Inhibitor Refill
Model # 2960-603
10
All Mosquito Deleto
TM
refills are available at www.coleman.com or 1-800-835-3278.
Replacement Parts
Parts List
No.
Part No.
Description
1 2950-1421 Cap Lift Grip
2 2910-5651 Cap Assembly
3 2950-2211 Rib (single component)
4 2910-0341 Igniter Assembly (no wires)
5 2910A0981 Thermometer
6 2910-3581 Transition Piece w/3 bolts
7 2910-0801 1 Individual Leg
8 2910-3601 Axle & 2 Wheels
9 2910-3591 Base Assembly (D-ring, 2
Feet, Support Bar, Hardware
10 2910-0931 Tank Holder Assembly
11 2950-3701 Tank Cover
12 2910-8001 Head Assembly
13 2910-0311 Ignitor Button
14 2910-0371 Gas Tip
7
6
10
11
8
9
1
2
13
4
5
3
12
14
11
12
Guarantee
Inhibitor
•
Guaranteed to repel mosquitoes.
Limited 60 Day Guarantee
Thank you for purchasing a Coleman
®
Mosquito Deleto TM . The Coleman Company, Inc. (“Coleman”) guarantees that this product will repel mosquitoes when used as directed, during mosquito season.
If for any reason you are not completely satisfied with this product during the first 60 days after you purchase the Mosquito Deleto TM , contact Coleman for a full refund. Proof of purchase shall be required to establish the purchase date. This warranty is valid only for the original retail purchaser and is not transferable. Coleman does not guarantee to eliminate mosquitoes, to trap mosquitoes during winter months or periods of cold weather, or to prevent mosquito bites. Follow all instructions and recommendations. If you have questions, contact Coleman at 1-800-835-3278 or www.coleman.com.
Warranty
1 Year Limited Warranty
The Coleman Company, Inc. (“Coleman“) warrants that for a period of one year from the date of purchase, this product will be free from defects in material and workmanship. Coleman, at its option, will repair or replace this product or any component of the product found to be defective during the warranty period. Replacement will be made with a new or remanufactured product or component.
If the product is no longer available, replacement may be made with a similar product of equal or greater value. This is your exclusive warranty.
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep the original sales receipt. Proof of purchase is required to obtain warranty performance. Coleman dealers, service centers, or retail stores selling Coleman products do not have the right to alter, modify or in any way change the terms and conditions of this warranty.
This warranty does not cover normal wear of parts, including chips, scratches, abrasions, discoloration or fading from use or exposure to sunlight or damage resulting from any of the following: negligent use or misuse of the product, use on improper voltage or current, use of non-Coleman accessories or parts, use contrary to the operating instructions or failure to follow maintenance instructions, commercial, in profit or non-profit instructional or rental applications, disassembly, repair or alteration by anyone other than Coleman or an authorized service center. Further, the warranty does not cover Acts of God, such as fire, flood, hurricanes and tornadoes.
Coleman shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. Some states, provinces or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state or province to province.
How to Obtain Warranty Service
Take the product to an authorized Coleman service center. You can find the nearest authorized
Coleman service center by calling 1-800-835-3278 or TDD 316-832-8707. If a service center is not conveniently located, attach a tag to the product that includes your name, address, daytime telephone number and description of the problem. Include a copy of the original sales receipt.
Carefully package the product and send either by UPS or Parcel Post INSURED with shipping and insurance prepaid to:
For products purchased in the United States:
The Coleman Company, Inc.
3600 North Hydraulic
Wichita, KS 67219
Do not mail products with fuel in tanks, or with disposable propane cylinders.
DO NOT RETURN THIS PRODUCT TO THE PLACE OF PURCHASE.
If you have any questions regarding this warranty please call 1-800-835-3278 or TDD 316-832-8707.
1 - YEAR
Trap
•
Guaranteed to trap & kill mosquitoes.
Limited 60 Day Guarantee
Thank you for purchasing a Coleman
®
Mosquito Deleto TM . The Coleman Company, Inc. (“Coleman”) guarantees that this product will trap and kill mosquitoes when used as directed, during mosquito season. If for any reason you are not completely satisfied with this product during the first 60 days after you purchase the Mosquito Deleto TM , contact Coleman for a full refund. Proof of purchase shall be required to establish the purchase date. This warranty is valid only for the original retail purchaser and is not transferable. Coleman does not guarantee to eliminate mosquitoes, to trap mosquitoes during winter months or periods of cold weather, or to prevent mosquito bites. Follow all instructions and recommendations. If you have questions, contact Coleman at 1-800-835-3278 or www.coleman.com.
Mosquito Deleto TM Octenol Lure Refill
Active Ingredient:
1-Octen-3-ol* 24.5%
Other Ingredients: 75.5%
Total 100.00%
*Contains 3.72 grams Octenol per lure.
EPA Reg. No. 70909-3-69269
EPA Est. No. 69269-KS-1
Keep Out of Reach of Children
If on skin or clothing
CAUTION
FIRST AID
• Take off contaminated clothing.
• Rinse skin immediately with plenty of water for 15 - 20 minutes.
• Call a poison control center or doctor for treatment advice.
If in eyes • Hold eye open and rinse slowly and gently with water for 15 - 20 minutes.
• Remove contact lenses, if present, after the first 5 minutes, then continue rinsing eye.
• Call a poison control center or doctor for treatment advice.
If inhaled • Move person to fresh air.
• If person is not breathing, call 911 or an ambulance, then give artificial respiration, preferably by mouth-to-mouth, if possible.
• Call a poison control center or doctor for further treatment advice.
If swallowed • Call poison control center or doctor immediately for treatment advice.
• Have person sip a glass of water if able to swallow.
• Do not induce vomiting unless told to do so by the poison control center or doctor.
• Do not give anything by mouth to an unconscious person.
Have the product container or label with you when calling a poison control center or doctor, or going for treatment.
Storage and Disposal:
Store this product in a cool, dry place and out of the reach of children until ready to use. Dispose of the used attractant lure by wrapping it in several layers of newspaper and dispose in the trash.
Directions for use: It is a violation of Federal law to use this product in a manner inconsistent with its labeling.
PRECAUTIONARY STATEMENTS
Hazards to Humans and Domestic Animals
Caution: Harmful if swallowed. Wash hands before eating, drinking, chewing gum, using tobacco or using bathroom facilities. Avoid contact of areas under foil wrapper with skin and eyes.
Manufactured for:
The Coleman Co., Inc. • 3600 N. Hydraulic • Wichita, KS 67219 www.coleman.com
1-800-835-3278 TDD: 1-316-832-8707
®
The Coleman Co., Inc.
3600 N. Hydraulic
Wichita, KS 67219 U.S.A.
1-800-835-3278
TDD: 316-832-8707 www.coleman.com