- Industrial & lab equipment
- Electrical equipment & supplies
- Power conditioning
- Signal converters
- User manual
advertisement
VLT® Soft Starter MCD 500
Total motor starting solution
VLT® Soft Starter MCD 500 is a total motor starting solution.
Current transformers measure motor current and provide feedback for controlled motor ramp profiles.
Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profiles for the application.
Adaptive Acceleration Control means that for each start and stop, the soft starter compares and adapts the process to the chosen profile fitting to the application.
VLT® Soft Starter MCD 500 has a four line graphical display and a logical keypad, making programming easy. Advanced setup is possible displaying operational status.
Three menu systems: Quick Menu, Application Setup and Main Menu provide the optimum programming approach.
Power range
21 – 1600 A, 7.5 – 850 kW
(1.2 MW inside Delta Connection) Versions for 200 – 690 VAC
Fully-equipped soft starter for motors up to 850 kW
» Total motor starting solution
» Advanced start, stop and protection features
»
» Inside Delta connection
»
Adaptive Acceleration Control
4-line graphical display
» Multiple programming setup menus
Options
» Modules for serial communication:
» DeviceNet
» EtherNet/IP
» PROFIBUS
» Modbus RTU
» USB
» VLT® Control Panel LCP 501
» PC software:
»
» WinStart
»
WinMaster
VLT® Motion Control Tool MCT 10
Dimensions
Current rating [A]
21,37,43 and 53
68
84, 89 and 105
131, 141, 195 and 215
245
331 and 396
469, 525, 632, 744, 826 and 961
1200, 1410 and 1600
Weight [kg] Height [mm] Width [mm] Depth [mm] Enclosure size
4.2
183
295 150 G1 4.5
4.9
14.9
24
30.2
60
120
438
440
640
856
275
424
433
585
213
250
296
295
364
G2
G3
G4
G5
Greenville Electrical
16 Cedarhurst Road
Belfast BT8 7RH
UK: 028 9064 5060
ROI: 1890 719 312 www.greenvilleidc.com
E-mail: [email protected]
VLT® Control Panel LCP
501
A full-function HMI interface – everything you can do on the VLT® Soft Starter MCD 500 is possible via the LCP 501
Danfoss “FC” menu structure and button interface concept
Multiple language selection incl. Russian and Chinese
Full graphics
Real language in 4 lines
Full parameter list, Quick Menu and application set up
Adjustable multiple monitoring views
A “copy-paste” function allows the user to copy parameter settings in the LCP and load to other units.
IP65, NEMA 12
3 m cable and mounting kit included
Specifications
Mains voltage (L1, L2, L3)
MCD5-xxxx-T5
MCD5-xxxx-T7
200 VAC ~ 525 VAC (± 10%)
MCD5-xxxx-T7 380 VAC ~ 600 VAC (± 10%)
(inside delta connection)
Control voltage (terminals A4, A5, A6)
CV1 (A5, A6)
CV2 (A5, A6)
CV2 (A4, A6)
Mains frequency
Rated insulation voltage to earth
Rated impulse withstand voltage
Form designation
24 VAC/VDC (± 20%)
110~120 VAC (+ 10% / - 15%)
220~240 VAC (+ 10% / - 15%)
50/60 Hz (± 10%)
600 VAC
4 kV
Bypassed or continuous, semiconductor motor starter form 1
Short circuit capability
Coordination with semiconductor fuses
Coordination with HRC fuses
MCD500-0021B to 0215B
MCD500-0245C
Type 2
Type 1
Prospective current of 65 kA
Prospective current of 85 kA
MCD500-1200C to 1600C Prospective current of 100 kA
Electromagnetic capability (compliant with EU Directive 89/336/EEC)
EMC Emissions (Terminals 13 & 14) IEC 60947-4-2 Class B and
Lloyds Marine No. 1 Specification
IEC 60947-4-2 EMC Immunity
Outputs
Relay outputs
Programmable outputs
Relay A (13, 14)
Relay B (21, 22, 24)
Relay C (33, 34)
Analog Output (07, 08)
Maximum load
24 VDC Output (16, 08) Maximum load
Environmental
Protection MCD5-0021B ~ MCD5-0105B
Protection MCD5-0131B ~ MCD5-1600C
Operating temperature
Storage temperature
Operating altitude
Humidity
Pollution degree
Heat Dissipation
During start
Normally open
Changeover
Normally open
0-20 mA or 4-20 mA (selectable)
600 Ω (12 VDC @ 20 mA) (accuracy ± 5%)
200 mA (accuracy ± 10%)
IP 20 & NEMA, UL Indoor Type 1
IP 00, UL Indoor Open Type
-10° C to 60° C, above 40° C with derating
- 25° C to + 60° C
0 – 1000 m, above 1000 m with derating
5% to 95% relative humidity
Pollution Degree 3
4.5 watts per ampere
Greenville Electrical
16 Cedarhurst Road
Belfast BT8 7RH
UK: 028 9064 5060
ROI: 1890 719 312 www.greenvilleidc.com
E-mail: [email protected]