Total motor starting solution

VLT® Soft Starter MCD 500 is a total motor starting solution.

Current transformers measure motor current and provide feedback for controlled motor ramp profiles.

Adaptive Acceleration Control (AAC) automatically employs the best starting and stopping profiles for the application.

Adaptive Acceleration Control means that for each start and stop, the soft starter compares and adapts the process to the chosen profile fitting to the application.

VLT® Soft Starter MCD 500 has a four line graphical display and a logical keypad, making programming easy. Advanced setup is possible displaying operational status.

Three menu systems: Quick Menu, Application Setup and Main Menu provide the optimum programming approach.

Power range

21 – 1600 A, 7.5 – 850 kW

(1.2 MW inside Delta Connection) Versions for 200 – 690 VAC

Fully-equipped soft starter for motors up to 850 kW

» Total motor starting solution

» Advanced start, stop and protection features

»

» Inside Delta connection

»

Adaptive Acceleration Control

4-line graphical display

» Multiple programming setup menus

Options

» Modules for serial communication:

» DeviceNet

» EtherNet/IP

» PROFIBUS

» Modbus RTU

» USB

» VLT® Control Panel LCP 501

» PC software:

»

» WinStart

»

WinMaster

VLT® Motion Control Tool MCT 10

Dimensions

Current rating [A]

21,37,43 and 53

68

84, 89 and 105

131, 141, 195 and 215

245

331 and 396

469, 525, 632, 744, 826 and 961

1200, 1410 and 1600

Weight [kg] Height [mm] Width [mm] Depth [mm] Enclosure size

4.2

183

295 150 G1 4.5

4.9

14.9

24

30.2

60

120

438

440

640

856

275

424

433

585

213

250

296

295

364

G2

G3

G4

G5

Greenville Electrical

16 Cedarhurst Road

Belfast BT8 7RH

UK: 028 9064 5060

ROI: 1890 719 312 www.greenvilleidc.com

E-mail: [email protected]

VLT® Control Panel LCP

501

A full-function HMI interface – everything you can do on the VLT® Soft Starter MCD 500 is possible via the LCP 501

Danfoss “FC” menu structure and button interface concept

Multiple language selection incl. Russian and Chinese

Full graphics

Real language in 4 lines

Full parameter list, Quick Menu and application set up

Adjustable multiple monitoring views

A “copy-paste” function allows the user to copy parameter settings in the LCP and load to other units.

IP65, NEMA 12

3 m cable and mounting kit included

Specifications

Mains voltage (L1, L2, L3)

MCD5-xxxx-T5

MCD5-xxxx-T7

200 VAC ~ 525 VAC (± 10%)

MCD5-xxxx-T7 380 VAC ~ 600 VAC (± 10%)

(inside delta connection)

Control voltage (terminals A4, A5, A6)

CV1 (A5, A6)

CV2 (A5, A6)

CV2 (A4, A6)

Mains frequency

Rated insulation voltage to earth

Rated impulse withstand voltage

Form designation

24 VAC/VDC (± 20%)

110~120 VAC (+ 10% / - 15%)

220~240 VAC (+ 10% / - 15%)

50/60 Hz (± 10%)

600 VAC

4 kV

Bypassed or continuous, semiconductor motor starter form 1

Short circuit capability

Coordination with semiconductor fuses

Coordination with HRC fuses

MCD500-0021B to 0215B

MCD500-0245C

Type 2

Type 1

Prospective current of 65 kA

Prospective current of 85 kA

MCD500-1200C to 1600C Prospective current of 100 kA

Electromagnetic capability (compliant with EU Directive 89/336/EEC)

EMC Emissions (Terminals 13 & 14) IEC 60947-4-2 Class B and

Lloyds Marine No. 1 Specification

IEC 60947-4-2 EMC Immunity

Outputs

Relay outputs

Programmable outputs

Relay A (13, 14)

Relay B (21, 22, 24)

Relay C (33, 34)

Analog Output (07, 08)

Maximum load

24 VDC Output (16, 08) Maximum load

Environmental

Protection MCD5-0021B ~ MCD5-0105B

Protection MCD5-0131B ~ MCD5-1600C

Operating temperature

Storage temperature

Operating altitude

Humidity

Pollution degree

Heat Dissipation

During start

Normally open

Changeover

Normally open

0-20 mA or 4-20 mA (selectable)

600 Ω (12 VDC @ 20 mA) (accuracy ± 5%)

200 mA (accuracy ± 10%)

IP 20 & NEMA, UL Indoor Type 1

IP 00, UL Indoor Open Type

-10° C to 60° C, above 40° C with derating

- 25° C to + 60° C

0 – 1000 m, above 1000 m with derating

5% to 95% relative humidity

Pollution Degree 3

4.5 watts per ampere

Greenville Electrical

16 Cedarhurst Road

Belfast BT8 7RH

UK: 028 9064 5060

ROI: 1890 719 312 www.greenvilleidc.com

E-mail: [email protected]

advertisement