Supero SuperWorkstation 7044A-8 User`s manual


Add to my manuals
124 Pages

advertisement

Supero SuperWorkstation 7044A-8 User`s manual | Manualzz

S

UPER

®

S

UPER

W

ORKSTATION

7044A-82

S

UPER

W

ORKSTATION

7044A-8

S

UPER

W

ORKSTATION

7044A-i2

S

UPER

W

ORKSTATION

7044A-i

USER’S MANUAL

1.0a

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates.

Please

Note: For the most up-to-date version of this manual, please see our web site at www.supermicro.com.

SUPERMICRO COMPUTER reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software, if any, and documentation may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any medium or machine without prior written consent.

IN NO EVENT WILL SUPERMICRO COMPUTER BE LIABLE FOR DIRECT, INDIRECT,

SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM

THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF

ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, THE VENDOR

SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED

OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING,

INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR

DATA.

Any disputes arising between manufacturer and customer shall be governed by the laws of

Santa Clara County in the State of California, USA. The State of California, County of

Santa Clara shall be the exclusive venue for the resolution of any such disputes.

Supermicro's total liability for all claims will not exceed the price paid for the hardware product.

Unless you request and receive written permission from SUPER MICRO COMPUTER, you may not copy any part of this document.

Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.

Copyright © 2005 by SUPER MICRO COMPUTER INC.

All rights reserved.

Printed in the United States of America

Preface

Preface

About This Manual

This manual is written for professional system integrators and PC technicians.

It provides information for the installation and use of the SuperWorkstation 7044A-

82/7044A-8/7044A-i2/7044A-i. Installation and maintainance should be performed by experienced technicians only.

The SuperWorkstation 7044A-82/7044A-8/7044A-i2/7044A-i is a high-end, dual processor workstation based on the SC743S1-645/SC743i-645 4U tower/ rackmount chassis and the X6DA8-G2/X6DA8-G/X6DAE-G2/X6DAE-G, a dual processor serverboard that supports single or dual Intel

®

Xeon

TM

processors at a Front Side (System) Bus speed of 800 MHz.

Manual Organization

Chapter 1: Introduction

The first chapter provides a checklist of the main components included with the server system and describes the main features of the SUPER X6DA8-G2/X6DA8-

G/X6DAE-G2/X6DAE-G serverboard and the SC743S1-645/SC743i-645 chassis, which comprise the SuperWorkstation 7044A-82/7044A-8/7044A-i2/7044A-i.

Chapter 2: Server Installation

This chapter describes the steps necessary to install the system into a rack and check out the server configuration prior to powering up the system. If your server was ordered without processor and memory components, this chapter will refer you to the appropriate sections of the manual for their installation.

Chapter 3: System Interface

Refer here for details on the system interface, which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system.

iii

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Chapter 4: System Safety

You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the

SuperWorkstation 7044A-82/7044A-8/7044A-i2/7044A-i.

Chapter 5: Advanced Serverboard Setup

Chapter 5 provides detailed information on the X6DA8-G2/X6DA8-G/X6DAE-G2/

X6DAE-G serverboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfiguring the serverboard.

Chapter 6: Advanced Chassis Setup

Refer to Chapter 6 for detailed information on the SC743S1-645/SC743i-645 server chassis. You should follow the procedures given in this chapter when installing, removing or reconfiguring SCSI or peripheral drives and when replacing system power supply units and cooling fans.

Chapter 7: BIOS

The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility.

Appendix A: BIOS POST Codes

Appendix B: Software Installation

Appendix C: System Specifications

iv

Notes

Preface v

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Table of Contents

Preface

About This Manual ....................................................................................................... iii

Manual Organization .................................................................................................... iii

Chapter 1: Introduction

1-1 Overview ............................................................................................................ 1-1

1-2 Serverboard Features ...................................................................................... 1-2

1-3 Server Chassis Features ................................................................................ 1-3

1-4 Contacting Supermicro ................................................................................... 1-6

Chapter 2: Quick Setup

2-1 Overview ............................................................................................................ 2-1

2-2 Unpacking the SuperWorkstation System .................................................... 2-1

2-3 Preparing for Setup ......................................................................................... 2-1

2-4 Installing the System into a Rack ................................................................. 2-4

2-5 Checking the Serverboard Setup ................................................................... 2-8

2-6 Checking the Drive Bay Setup ....................................................................... 2-9

Chapter 3: System Interface

3-1 Overview ............................................................................................................ 3-1

3-2 Control Panel Buttons ..................................................................................... 3-1

Power ......................................................................................................... 3-1

Reset .......................................................................................................... 3-1

3-3 Control Panel LEDs ......................................................................................... 3-2

Power ......................................................................................................... 3-2

HDD ............................................................................................................ 3-2

NIC .............................................................................................................. 3-2

Overheat ..................................................................................................... 3-2

Power Fail .................................................................................................. 3-3

3-4 SCSI Drive LEDs ............................................................................................. 3-3

3-5 LAN (Ethernet) Port LEDs .............................................................................. 3-3

Chapter 4: System Safety

4-1 Electrical Safety Precautions ........................................................................... 4-1

4-2 General Safety Precautions ............................................................................. 4-2

4-3 ESD Safety Precautions ................................................................................... 4-3

4-4 Operating Precautions ...................................................................................... 4-4 vi

Table of Contents

Chapter 5: Advanced Serverboard Setup

5-1 Handling the Serverboard ............................................................................. 5-1

5-2 PGA Processor and Heatsink Installation .................................................. 5-2

5-3 Connecting Cables ......................................................................................... 5-5

Connecting Data Cables ......................................................................... 5-5

Connecting Power Cables ...................................................................... 5-5

Connecting the Control Panel ................................................................ 5-6

5-4 I/O Ports ........................................................................................................... 5-7

5-5 Installing Memory ............................................................................................ 5-7

5-6 Adding PCI Cards ........................................................................................... 5-9

5-7 Serverboard Details ....................................................................................... 5-9

X6DA8-G2/X6DA8-G/X6DAE-G2/X6DAE-G Layout .......................... 5-10

X6DA8-G2/X6DA8-G/X6DAE-G2/X6DAE-G Quick Reference ......... 5-11

5-8 Connector Definitions .................................................................................. 5-12

ATX Power Connector .......................................................................... 5-12

Processor Power Connector ............................................................... 5-12

NMI Button ............................................................................................... 5-12

Power LED .............................................................................................. 5-12

HDD LED .................................................................................................. 5-13

NIC LEDs ................................................................................................. 5-13

Overheat LED (OH) ............................................................................... 5-13

Power Fail LED ...................................................................................... 5-13

Reset Button ........................................................................................... 5-14

Power Button ......................................................................................... 5-14

Chassis Intrusion ................................................................................... 5-14

Universal Serial Bus (USB0/1) ............................................................ 5-14

Fan Headers ........................................................................................... 5-15

Serial Ports ............................................................................................. 5-15

GLAN 1/2 (Ethernet Ports) ................................................................... 5-15

ATX PS/2 Keyboard and Mouse Ports ............................................... 5-15

Power LED/Speaker/NMI ....................................................................... 5-16

Wake-On-Ring ........................................................................................ 5-16

Wake-On-LAN ........................................................................................ 5-16

SMB .......................................................................................................... 5-16

Power Fault ............................................................................................ 5-17

Keylock Fault .......................................................................................... 5-17

Power Supply Fail Alarm Reset .......................................................... 5-17

5-9 Jumper Settings ............................................................................................ 5-18

Explanation of Jumpers ........................................................................ 5-18 vii

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

CMOS Clear ............................................................................................. 5-18

GLAN Enable/Disable ............................................................................. 5-19

SCSI Controller Enable/Disable ............................................................ 5-19

SCSI Termination Enable/Disable ......................................................... 5-19

Watch Dog Enable/Disable ................................................................... 5-20

AC'97 Audio Enable/Disable ................................................................. 5-20

Third Power Supply Alarm Enable/Disable ........................................ 5-21

Power Force On Enable/Disable ......................................................... 5-21

5-10 Onboard Indicators ...................................................................................... 5-22

GLAN1/GLAN2 LEDs ............................................................................. 5-22

5-11 Parallel Port, Floppy/Hard Disk Drive and SCSI Connections ............... 5-22

Parallel Port Connector ......................................................................... 5-22

Floppy Connector ................................................................................... 5-23

IDE Connectors ...................................................................................... 5-23

Ultra320 SCSI Connectors .................................................................... 5-24

Chapter 6: Advanced Chassis Setup

6-1 Static-Sensitive Devices ................................................................................. 6-1

6-2 Front Control Panel ........................................................................................ 6-3

6-3 System Fans ................................................................................................... 6-4

Fan Failure ................................................................................................ 6-4

Replacing System Fans .......................................................................... 6-4

6-4 Drive Bay Installation ..................................................................................... 6-6

SCSI Drives ............................................................................................... 6-6

Installing Components in the 5.25" Drive Bays .................................. 6-9

6-5 Power Supply ............................................................................................... 6-10

Power Supply Failure ........................................................................... 6-10

Replacing the Power Supply ............................................................... 6-10

Chapter 7: BIOS

7-1 Introduction ...................................................................................................... 7-1

7-2 Running Setup ................................................................................................. 7-2

7-3 Main BIOS Setup ............................................................................................. 7-2

7-4 Advanced Setup ............................................................................................. 7-7

7-5 Security .......................................................................................................... 7-19

7-6 Boot ................................................................................................................ 7-21

7-7 Exit .................................................................................................................. 7-22 viii

Table of Contents

Appendices:

Appendix A: BIOS POST Codes ........................................................................... A-1

Appendix B: Software Installation ....................................................................... B-1

Appendix C: System Specifications .................................................................... C-1 ix

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Notes

x

Chapter 1: Introduction

Chapter 1

Introduction

1-1 Overview

The Supermicro SuperWorkstation 7044A-82/7044A-8/7044A-i2/7044A-i is a high-end dual processor workstation that can be utilized either in a tower or in a rackmount configuration. The 7044A-82/7044A-8/7044A-i2/7044A-i is comprised of two main subsystems: the SC743S1-645/SC743i-645 high-end server chassis and the X6DA8-G2/X6DA8-G/X6DAE-G2/X6DAE-G dual Xeon TM processor serverboard. Please refer to our web site for information on operating systems that have been certified for use with your workstation.

z z z z z z z z

In addition to the serverboard and chassis, various hardware components have been included with the SuperWorkstation, as listed below: z z

One (1) 3.5" floppy drive [FPD-PNSC-02(1)]

Four (4) hot-swap 8-cm chassis PWM fans (FAN-0074)

One (1) air shroud (CSE-PT54)

Two (2) 5.25" dummy drive trays [CSE-PT36(B)]

One (1) front control panel cable (CBL-0049)

One (1) round floppy cable (CBL-0040)

One (1) IDE cable (CBL-0036, 7044A-i2/7044A-i only)

One (1) round CD-ROM cable (CBL-0039)

One (1) I/O shield (CSE-PT57)

SCSI Accessories (7044A-82/7044A-8 only)

One (1) SCSI backplane with SAF-TE (CSE-SCA-743S1)

One (1) 2' SCSI drop cable (CBL-037-U320)

Eight (8) SCA 1-inch high SCSI drive carriers [CSE-PT17(B)] z

Optional: Two (2) Xeon passive heatsinks (SNK-P0010)

One (1) rackmount kit [CSE-PT26(B)]

1-1

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

1-2 Serverboard Features

At the heart of the 7044A-82/7044A-8/7044A-i2/7044A-i lies the X6DA8-G2/

X6DA8-G/X6DAE-G2/X6DAE-G, a dual processor serverboard based on Intel's

E7525 chipset and designed to provide maximum performance. Below are the main features of the X6DA8-G2/X6DA8-G/X6DAE-G2/X6DAE-G. (See Figure 1-1 for a block diagram of the E7525 chipset).

Processors

The X6DA8-G2/X6DA8-G/X6DAE-G2/X6DAE-G supports single or dual 604-pin

Intel Xeon processors at a FSB speed of 800 MHz. Please refer to the serverboard description pages on our web site for a complete listing of supported processors (http://www.supermicro.com).

Memory

The X6DA8-G2/X6DAE-G2 has eight 240-pin DIMM slots that can support up to

16 GB of registered ECC DDR2-400 (PC3200) SDRAM. The memory is an interleaved configuration, which requires modules of the same size and speed to be installed in pairs.

The X6DA8-G/XDAE-G has eight 184-pin DIMM slots that can support up to 16

GB of registered ECC DDR333 or 32 GB of registered ECC DDR266 SDRAM. The memory is an interleaved configuration, which requires modules of the same size and speed to be installed in pairs.

Onboard SCSI (X6DA8-G2/X6DA8-G only)

Onboard SCSI is provided with an Adaptec AIC-7902 SCSI chip, which supports dual channel, Ultra320 SCSI at a throughput of 320 MB/sec for each channel.

The X6DA8-G2/X6DA8-G provides two LVD Ultra320 SCSI ports.

PCI Expansion Slots

The X6DA8-G2/X6DA8-G/X6DAE-G2/X6DAE-G has six PCI expansion slots, which includes one x16@4GB/sec PCI-Express slot, one x4@2GB/sec PCI-

Express slot, three 64-bit PCI-X slots (one 64-bit PCI-X 133 slot, one PCI-X 100 slot and one PCI-X 100MHz ZCR slot) and one 32-bit 33MHz PCI slot (w/PCI graphics card support).

1-2

Chapter 1: Introduction

Onboard Controllers/Ports

One floppy drive controller and two onboard ATA/100 controllers are provided to support up to four hard drives or ATAPI devices. The color-coded I/O ports include two COM ports, a parallel port, four USB 2.0 ports, PS/2 mouse and keyboard ports and Line-In, Line-Out and Mic jacks. Two front side USB ports are also included on the front of the chassis. The X6DA8-G2 and X6DAE-G2 have two and the X6DA8-G and X6DAE-G have one gigabit Ethernet port.

Other Features

Other onboard features that promote system health include onboard voltage monitors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU overheat sensors, virus protection and BIOS rescue.

1-3 Server Chassis Features

The SuperWorkstation 7044A-82/7044A-8/7044A-i2/7044A-i is a scaleable server platform designed with today's most state-of-the-art features. The following is a general outline of the main features of the SC743S1-645/SC743i-645 server chassis. (7044A-82/7044A-8: SC743S1-645 7044A-i2/7044A-i: SC743i-645

Note: The SC743S1-645 and SC743i-645 are two versions of the same chassis.

The only difference between them is the SC743S1-645 is equipped with a SCSI backplane and drive trays while the SC743i-645 is not.

System Power

The 7044A-82/7044A-8/7044A-i2/7044A-i features a single 645W power supply.

This power supply unit has been designed to operate at a low noise level to make it ideal for use in a workstation environment.

SCSI Subsystem (7044A-82/7044A-8 only)

The SCSI subsystem supports up to eight 80-pin SCA Ultra320 SCSI hard drives.

(Any standard 1" drives are supported. SCA = Single Connection Attachment.)

The SCSI drives are connected to a single-channel SCA backplane with SAF-TE.

The SCSI drives are also hot-swap units. A RAID controller card can be used with the SCA backplane to provide data security.

Note: The operating system you use must have RAID support to enable the hotswap capability of the SCSI drives.

1-3

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Front Control Panel

The SuperWorkstation 7044A-82/7044A-8/7044A-i2/7044A-i's control panel provides you with system monitoring and control. LEDs indicate system power,

HDD activity, network activity, overheat condition and power supply failure. A main power button and a system reset button are also included.

Note: the power supply fail LED is intended for use with redundant power supply systems and so is not needed for the 7044A-82/7044A-8/7044A-i2/7044A-i.

I/O Backplane

The SC743S1-645/SC743i-645 is an ATX form factor chassis that can be used as a tower or mounted in a 4U rackmount configuration. The I/O backplane provides six expansion slots, two COM ports, a parallel port, four USB 2.0 ports, PS/2 mouse and keyboard ports, one or two (depending on the serverboard) gigabit

Ethernet port(s) and Line-In, Line-Out and Microphone jacks (see Figure 5-3).

Cooling System

The SC743S1-645/SC743i-645 chassis has an innovative cooling design that includes four 8-cm hot-plug PWM (Pulse Width Modulation) system cooling fans located in the middle of the chassis. The chassis fans work with an air shroud to cool the areas where the most heat is generated. All chassis fans operate continuously at 5000 rpm.

1-4

Chapter 1: Introduction

Figure 1-1. Intel E7525 Chipset:

System Block Diagram

Note: This is a general block diagram. Please see Chapter 5 for details.

NOCONA PROCESSOR#1

VRM NOCONA PROCESSOR#2 CLOCK

1 PCI - X

SL OT 1

J 12

1 PCI - X

SL OT 2

J 13

SCSI

7902

1 PCI - X

SL OT 3

J 14

Gbi t L AN

PCI - X BUS( 100 MHZ)

PCI - X BUS( 100 MHZ)

1 PCI - EXP

SL OT 6

J 15

A

PXH

B

X4 PCI EXP. A X8

1 PCI - EXP

SL OT 4

J 17

X4

PCI EXP. B, C ( X16)

UDMA/ 100 I DE

PRI / SEC

SATA

0, 1

SATA

USB PORT

0, 1, 2, 3,

5, 6, 7, 8

USB

H/ W

MONI TOR

MCH

DDRI I - 400

DDRI I - 400

4 DDR I I - 400

DI MMs

4 DDR I I - 400

DI MMs

HUB

I CH5R

PCI BUS( 32- BI T) PCI 32 BI T

SL OT 5

J 19

AC 97

LPC BUS

L PC I / O BMC CON.

FWH

KB.

MS.

FDD.

SER. 1

SER. 2

1-5

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

1-4 Contacting Supermicro

Headquarters

Address: SuperMicro Computer, Inc.

980 Rock Ave.

San Jose, CA 95131 U.S.A.

+1 (408) 503-8000 Tel:

Fax:

Email:

+1 (408) 503-8008 [email protected] (General Information) [email protected] (Technical Support)

Web Site: www.supermicro.com

Europe

Address:

Tel:

Fax:

Email:

SuperMicro Computer B.V.

Het Sterrenbeeld 28, 5215 ML

's-Hertogenbosch, The Netherlands

+31 (0) 73-6400390

+31 (0) 73-6416525 [email protected] (General Information) [email protected] (Technical Support) [email protected] (Customer Support)

Asia-Pacific

Address: SuperMicro, Taiwan

Tel:

Fax:

4F, No. 232-1, Liancheng Rd.

Chung-Ho 235, Taipei, Taiwan, R.O.C.

+886-(2) 8226-3990

+886-(2) 8226-3991

Web Site: www.supermicro.com.tw

Technical Support:

Email:

Tel: [email protected]

886-2-8228-1366, ext. 132 or 139

1-6

Chapter 2: Server Installation

Chapter 2

Server Installation

2-1 Overview

This chapter provides a quick setup checklist to get your SuperWorkstation

7044A-82/7044A-8/7044A-i2/7044A-i up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory preinstalled. If your system is not already fully integrated with a serverboard, processors, system memory etc., please turn to the chapter or section noted in each step for details on installing specific components. The SuperWorkstation 7044A-82/7044A-8/7044A-i2/7044A-i may be employed either as a tower or rackmounted as a 4U chassis. If using it in a tower configuration, please read Server Precautions in the next section and then skip ahead to Section 2-5.

2-2 Unpacking the System

You should inspect the box the system was shipped in and note if it was damaged in any way. If the server itself shows damage you should file a damage claim with the carrier who delivered it.

Decide on a suitable location for the SuperWorkstation 7044A-82/7044A-8/

7044A-i2/7044A-i. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are generated. You will also need it placed near a grounded power outlet. Read the Rack and Server Precautions in the next section.

2-3 Preparing for Setup

The box the system was shipped in may include two sets of rail assemblies, two rail mounting brackets and mounting screws needed for installing the system into a rack (optional kit). Follow the steps in the order given to complete the installation process in a minimum amount of time. Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow.

2-1

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Choosing a Setup Location:

- Leave enough clearance in front of the system to enable you to open the front door completely (~25 inches).

- Leave approximately 30 inches of clearance in the back of the system to allow for sufficient airflow and ease in servicing.

- This product is for installation in a Restricted Access Location only (dedicated equipment rooms, service closets, etc.)

!

Warnings and Precautions!

!

Rack Precautions:

- Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them.

- In single rack installation, stabilizers should be attached to the rack.

- In multiple rack installations, the racks should be coupled together.

- Always make sure the rack is stable before extending a component from the rack.

- You should extend only one component at a time - extending two or more simultaneously may cause the rack to become unstable.

Server Precautions:

- Review the electrical and general safety precautions in Chapter 4.

- Determine the placement of each component in the rack before you install the rails.

-

Install the heaviest server components on the bottom of the rack first, and then work up.

- Use a regulating uninterruptible power supply (UPS) to protect the server from power surges, voltage spikes and to keep your system operating in case of a power failure.

-

Allow the hot plug SCSI drives and power supply units to cool before touching them.

-

Always keep the rack's front door and all panels and components on the servers closed when not servicing to maintain proper cooling.

2-2

Chapter 2: Server Installation

Rack Mounting Considerations

Ambient Operating Temperature

If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).

Reduced Airflow

Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised.

Mechanical Loading

Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.

Circuit Overloading

Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

Reliable Ground

A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit

(i.e. the use of power strips, etc.).

2-3

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

2-4 Installing the System into a Rack

This section provides information on installing the system into a rack unit. Rack installation requires the use of the optional rackmount kit [CSE-PT26(B)]. If the system has already been mounted into a rack or if you are using it as a tower, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. The following is a guideline for installing the workstation into a rack with the rack rails provided in the rackmount kit. You should also refer to the installation instructions that came with the rack unit you are using.

Identifying the Sections of the Rack Rails:

The optional rackmount kit (CSE-PT26 or CSE-PT26B - black) includes two rack rail assemblies. Each of these assemblies consist of three sections: an inner fixed chassis rail that secures to the chassis, an outer rack rail that secures directly to the rack itself and two rail brackets, which also attack to the rack (see

Figure 2-1.) The inner and outer rails must be detached from each other to install.

To remove the inner chassis rail, pull it out as far as possible - you should hear a "click" sound as a locking tab emerges from inside the rail assembly and locks the inner rail. Depress the locking tab to pull the inner rail completely out. Do this for both assemblies (one for each side).

Figure 2-1. Identifying the Sections of the Rack Rails

Outer rail

Inner rail

2-4

Rail brackets

Chapter 2: Server Installation

Installing the Chassis Rails:

You will need to remove the top bezel cover and the feet to add rack rails to the chassis. First, remove the top and right covers (top and left covers when standing as a tower chassis) by first removing the screws that secure them to the chassis.

Depress the button on the top (side if tower) of the chassis to release the cover and then pull the cover off. Then unscrew the four feet and remove them from the chassis (see Figure 2-2).

You can now attach rack rails to the top and bottom (now the sides) of the chassis. First add the rack handles. Then position the inner chassis rail sections you just removed along the side of the chassis making sure the screw holes line up. Note that these two rails are left/right specific. Screw the rail securely to the side of the chassis (see Figure 2-3). Repeat this procedure for the other rail on the other side of the chassis. You will also need to attach the rail brackets when installing into a telco rack.

Locking Tabs: As mentioned, the chassis rails have a locking tab, which serves two functions. The first is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing.

Figure 2-2. Preparing to Install the Chassis Rails

2-5

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Figure 2-3. Installing the Rails to the Chassis

Installing the Rack Rails:

Determine where you want to place the SuperWorkstation 7044A-82/7044A-8/

7044A-i2/7044A-i in the rack. (See Rack and Server Precautions in Section 2-

3.) Position the fixed rack rail/sliding rail guide assemblies at the desired location in the rack, keeping the sliding rail guide facing the inside of the rack.

Screw the assembly securely to the rack using the brackets provided. Attach the other assembly to the other side of the rack, making both are at the exact same height and with the rail guides facing inward.

2-6

Chapter 2: Server Installation

Installing the Server into the Rack:

You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. You should have two brackets in the rack mount kit. Install these first keeping in mind that they are left/right specific (marked with "L" and "R"). Then, line up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting).

When the server has been pushed completely into the rack, you should hear the locking tabs "click". Finish by inserting and tightening the thumbscrews that hold the front of the server to the rack (see Figure 2-4).

Figure 2-4. Installing the Server into a Rack

2-7

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

2-5 Checking the Serverboard Setup

After setting up the the system, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made.

1. Accessing the inside of the system (see Figure 2-5):

(If rack mounted, first release the retention screws that secure the unit to the rack. Grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click").) There are two screws that secure the cover to the chassis - remove these first. Depress the button on the top (side if tower) of the chassis to release the cover. You can then lift the cover from the chassis to gain full access to the inside of the server.

2. Check the CPUs (processors):

You should have one or two processors already installed into the serverboard. Each processor should have its own heatsink attached.

See Chapter 5 for instructions on processor installation.

3. CPU clock ratio setting:

The CPU speed should be automatically detected. If not, you will need to set the correct speed with the BIOS Setup utility. See the Frequency

Ratio setting in BIOS (Chapter 7) to set the processor speed.

4. Check the system memory:

Your workstation may have come with system memory already installed.

Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5.

5. Installing add-on cards:

If desired, you can install add-on cards to the system. See Chapter 5 for details on installing PCI add-on cards.

6. Check all cable connections and airflow:

Make sure all power and data cables are properly connected and not blocking the chassis airflow. See Chapter 5 for details on cable connections.

2-8

Chapter 2: Server Installation

2-6 Checking the Drive Bay Setup

Next, you should check to make sure the peripheral drives and the SCSI drives and SCA backplane have been properly installed and all connections have been made. (SCSI applies to 7044A-82/7044A-8 only.)

1. Accessing the drive bays:

All drives can be accessed from the front of the server. For servicing the CD-ROM, IDE hard drives and floppy drives, you will need to remove the top/left chassis cover. The SCSI disk drives can be installed and removed from the front of the chassis without removing any chassis covers.

2. Installing components into the 5.25" drive bays:

To install components into the 5.25" drive bays, you must first remove the top/ left chassis cover as described in the previous section. Refer to Chapter 6 for details.

3. Installing CD-ROM and floppy disk drives:

Refer to Chapter 6 if you need to reinstall a CD-ROM and/or floppy disk drive to the system.

4. Check the SCSI disk drives:

Depending upon your system's configuration, your system may have one or more drives already installed. If you need to install SCSI drives, please refer to Chapter 6.

5. Check the airflow:

Airflow is provided by four hot-swap 8-cm chassis fans working in conjunction with an air shroud. The system component layout was carefully designed to promote sufficient airflow through the chassis. Also note that all power and data cables have been routed in such a way that they do not block the airflow generated by the fans. Keep this in mind when you reroute them after working on the system.

2-9

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

6. Supplying power to the system:

The last thing you must do is to provide input power to the system. Plug the power cord from the power supply unit into a high-quality power strip that offers protection from electrical noise and power surges. It is recommended that you use an uninterruptible power supply (UPS). Finally, depress the power on button on the front of the chassis.

Figure 2-5. Accessing the Inside of the System

(Rack Configuration shown)

2-10

Chapter 3: System Interface

Chapter 3

System Interface

3-1 Overview

There are several LEDs on the control panel as well as two for each SCSI drive carrier (7044A-82/7044A-8 only) and the Ethernet port(s). These LEDs are to keep you constantly informed of the overall status of the system and the activity and health of specific components. There are also two buttons on the chassis control panel.

3-2 Control Panel Buttons

There are two push-button buttons located on the front of the chassis. These are

(in order from left to right) a power on/off button and a reset button.

z

POWER: This is the main power button, which is used to apply or turn off the main system power. Turning off system power with this button removes the main power but keeps standby power supplied to the system.

z

RESET:

Use the reset button to reboot the system.

3-1

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

3-3 Control Panel LEDs

The control panel located on the front of the SC743S1-645/SC743i-645 chassis has six LEDs that provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take.

z

Power:

Indicates external power is being supplied to the system's power supply unit. This LED should normally be illuminated when the system is operating.

z

HDD: Indicates IDE channel activity. On the 7044A-82 and 7044A-8/

7044A-i2 and 7044A-i, this LED indicates SCSI/IDE drive activity when flashing.

z

NIC:

Indicates network activity on LAN1 when flashing.

z

NIC: Indicates network activity on LAN2 when flashing (7044A-82/7044Ai2 only).

z

Overheat: When this LED flashes, it indicates a fan failure. When on continuously it indicates an overheat condition, which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm. Check the routing of the cables and make sure all fans are present and operating normally. You should also check to make sure that the chassis covers are installed. Finally, verify that the heatsinks are installed properly (see Chapter

5). This LED will remain flashing or on as long as the indicated condition exists.

3-2

Chapter 3: System Interface z

Power Fail: Indicates a power supply module has failed. This LED is inended for use with systems that have redundant power supply modules and therefore is not used with the SuperWorkstation 7044A-82/7044A-8/7044A-i2/

7044A-i.

3-4 SCSI Drive LEDs (7044A-82/7044A-8 only)

Each SCSI drive carrier has two LEDs.

z

Green:

When illuminated, the green LED on the front of the SCSI drive carrier indicates drive activity. A connection to the SCSI SCA backplane enables this LED to blink on and off when that particular drive is being accessed.

z

Red: A SAF-TE compliant backplane is needed to activate the red

LEDs, which indicate a drive failure. Please refer to Chapter 6 for instructions on replacing failed SCSI drives.

3-5 LAN (Ethernet) Port LEDs

The LAN Ethernet port(s) (located beside the VGA port) each have a yellow and a green LED. The yellow (left) LED indicates activity while the other (right) LED may be green, orange or off to indicate the speed of the connection. See the tables below for the functions associated with these LEDs.

Note: the 7044A-82 and 7044A-i2 have two Ethernet ports. The 7044A-8 and the

7044A-i have a single Ethernet port.

Gb LAN Left LED

Indicator

LED

Color

Off

Yellow

Definition

Not Active

Active

Gb LAN Right LED

Indicator

LED

Color

Off

Green

Orange

Definition

No Connection

100 MHz

1 GHz

3-3

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Notes

3-4

Chapter 4

System Safety

4-1 Electrical Safety Precautions

Chapter 4: System Safety

!

Basic electrical safety precautions should be followed to protect yourself from harm and the SuperWorkstation 7044A-82/7044A-8/7044A-i2/7044A-i from damage: z Be aware of the locations of the power on/off switch on the chassis as well as the room's emergency power-off switch, disconnection switch or electrical outlet. If an electrical accident occurs, you can then quickly remove power from the system.

z Do not work alone when working with high voltage components.

z Power should always be disconnected from the system when removing or installing main system components, such as the serverboard, memory modules and the CD-ROM and floppy drives (not necessary for SCSI drives). When disconnecting power, you should first power down the system with the operating system and then unplug the power cord from the power supply unit.

z When working around exposed electrical circuits, another person who is familiar with the power-off controls should be nearby to switch off the power if necessary.

z Use only one hand when working with powered-on electrical equipment. This is to avoid making a complete circuit, which will cause electrical shock. Use extreme caution when using metal tools, which can easily damage any electrical components or circuit boards they come into contact with.

z Do not use mats designed to decrease electrostatic discharge as protection from electrical shock. Instead, use rubber mats that have been specifically designed as electrical insulators.

4-1

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual z The power supply power cord must include a grounding plug and must be plugged into grounded electrical outlets.

z Serverboard Battery: CAUTION - There is a danger of explosion if the onboard battery is installed backwards, which will reverse its polarities. The positive side of the battery should be facing up and the negative side should facing the serverboard. This battery must be replaced only with the same or an equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions. See Figure 4-1.

z CD-ROM Laser: CAUTION - this server may have come equipped with a CD-ROM drive. To prevent direct exposure to the laser beam and hazardous radiation exposure, do not open the enclosure or use the unit in any unconventional way.

4-2 General Safety Precautions

!

Follow these rules to ensure general safety: z Keep the area around the SuperWorkstation 7044A-82/7044A-8/

7044A-i2/7044A-i clean and free of clutter.

z The SuperWorkstation 7044A-82/7044A-8/7044A-i2/7044A-i weighs approximately 63 lbs. When lifting the system, two people at either end should lift slowly with their feet spread out to distribute the weight. Always keep your back straight and lift with your legs.

z Place the chassis top/side cover and any system components that have been removed away from the system or on a table so that they won't accidentally be stepped on.

z While working on the system, do not wear loose clothing such as neckties and unbuttoned shirt sleeves, which can come into contact with electrical circuits or be pulled into a cooling fan.

z Remove any jewelry or metal objects from your body, which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas

4-2

Chapter 4: System Safety where power is present.

z After accessing the inside of the system, close the system back up and (if rackmounted) secure it to the rack unit with the retention screws after ensuring that all connections have been made.

4-3 ESD Precautions

!

Electrostatic discharge (ESD) is generated by two objects with different electrical charges coming into contact with each other. An electrical discharge is created to neutralize this difference, which can damage electronic components and printed circuit boards. The following measures are generally sufficient to neutralize this difference before contact is made to protect your equipment from ESD: z Use a grounded wrist strap designed to prevent static discharge.

z Keep all components and printed circuit boards (PCBs) in their antistatic bags until ready for use.

z Touch a grounded metal object before removing the board from the antistatic bag.

z Do not let components or PCBs come into contact with your clothing, which may retain a charge even if you are wearing a wrist strap.

z Handle a board by its edges only; do not touch its components, peripheral chips, memory modules or contacts. z When handling chips or modules, avoid touching their pins.

z Put the serverboard and peripherals back into their antistatic bags when not in use.

4-3

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual z For grounding purposes, make sure your computer chassis provides excellent conductivity between the power supply, the case, the mounting fasteners and the serverboard.

4-4 Operating Precautions

!

Care must be taken to assure that all chassis covers are in place when the SuperWorkstation 7044A-82/7044A-8/7044A-i2/7044A-i is operating to ensure proper cooling. Out of warranty damage to the 7044A-82/7044A-8/

7044A-i2/7044A-i system can occur if this practice is not strictly followed.

LITHIUM BATTERY

BATTERY HOLDER

Figure 4-1. Installing the Onboard Battery

LITHIUM BATTERY

OR

BATTERY HOLDER

4-4

Chapter 5: Advanced Serverboard Setup

Chapter 5

Advanced Serverboard Setup

This chapter covers the steps required to install processors and heatsinks to the

X6DA8-G2/X6DA8-G/X6DAE-G2/X6DAE-G serverboard, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are described and a layout and quick reference chart are included in this chapter.

Remember to close the chassis completely when you have finished working on the serverboard to protect and cool the system sufficiently.

5-1 Handling the Serverboard

Static electrical discharge can damage electronic components. To prevent damage to printed circuit boards, it is important to handle them very carefully (see Chapter 4). Also note that the size and weight of the serverboard can cause it to bend if handled improperly, which may result in damage. To prevent the serverboard from bending, keep one hand under the center of the board to support it when handling. The following measures are generally sufficient to protect your equipment from static discharge.

Precautions

• Use a grounded wrist strap designed to prevent static discharge.

• Touch a grounded metal object before removing any board from its antistatic bag.

• Handle a board by its edges only; do not touch its components, peripheral chips, memory modules or gold contacts.

• When handling chips or modules, avoid touching their pins.

• Put the serverboard, add-on cards and peripherals back into their antistatic bags when not in use.

Unpacking

The serverboard is shipped in antistatic packaging to avoid static damage.

When unpacking the board, make sure the person handling it is static protected.

5-1

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

5-2 PGA Processor and Heatsink Installation

!

When handling the processor package, avoid placing direct pressure on the label area of the fan. Also, do not place the motherboard on a conductive surface, which can damage the

BIOS battery and prevent the system from booting up.

IMPORTANT: Always connect the power cord last and always remove it before adding, removing or changing any hardware components. Make sure that you install the processor into the CPU socket before you install the CPU heat sink.

CPU Installation

1. Lift the lever on the CPU socket: Lift

the lever completely as shown on the picture on the right; otherwise, you will damage the CPU socket when power

is applied. Install CPU1 first.

Socket lever

2. Insert the CPU in the socket, making sure that pin 1 of the CPU aligns with pin 1 of the socket (both corners are marked with a triangle).

When using only one CPU, install it into CPU socket #1. (Socket #2 is automatically disabled if only one

CPU is used.)

3. Press the lever down until you hear a *click*, which means the

CPU is securely installed in the

CPU socket.

Pin 1

Socket lever in the locking Position

5-2

Chapter 5: Advanced Serverboard Setup

Heatsink Installation*

1. Do not apply any thermal compound to the heatsink or the CPU die; the required amount has already been applied.

2. Place the heatsink on top of the

CPU so that the four mounting holes are aligned with those on the retention mechanism.

3. Screw in two diagonal screws until snug (do not fully tighten the screws to avoid possible damage to the CPU). The screw in the other two diagonal screws until snug.

4. Finish the installation by fully tightening all four screws.

*Note: This heatsink (SNK-P0010) is a passive heatink. It is an optional part that must be purchased separately.

Figure 5-1. 604-pin PGA Socket: Empty and with Processor Installed

!

Warning!

Make sure you lift the lever completely when installing the CPU. If the lever is only partly raised, damage to the socket or CPU may result.

Empty socket With processor installed

Lever

Triangle (pin 1)

5-3

Triangle locating pin 1

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Removing the Heatsink/CPU

!

IMPORTANT: Removal of the heatsink or the CPU is not recommended. However, if you do need to remove the heatsink, please follow the instructions below to prevent damaging the CPU or the

CPU socket.

1. Unscrew and remove the heatsink screws from the serverboard in the sequence as show in the picture on the right.

2. Hold the heatsink as show in the picture on the right and gently wriggle the heatsink to loosen it from the CPU. (Do not use excessive force when wriggling the heatsink!!)

3. Once the heatsink has been loosened from the CPU, remove the heatsink from the CPU socket.

4. Clean the surface of the CPU and the heatsink to get rid of the old thermal grease. Reapply the proper amount of thermal grease on the surface before you re-install the heatsink to the CPU.

5-4

Chapter 5: Advanced Serverboard Setup

5-3 Connecting Cables

Now that the processors are installed, the next step is to connect the cables to the serverboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables.

Connecting Data Cables

The ribbon cables used to transfer data from the peripheral devices have been carefully routed in preconfigured systems to prevent them from blocking the flow of cooling air that moves through the system from front to back.

If you need to disconnect any of these cables, you should take care to keep them routed as they were originally after reconnecting them (make sure the red wires connect to the pin 1 locations). If you are configuring the system, keep the airflow in mind when routing the cables. The following data cables (with their motherboard connector locations noted) should be connected. See the serverboard layout figure in this chapter for connector locations.

z Ultra320 LVD SCSI Cables (JA1, X6DA8-G2/X6DA8-G only) z IDE#1 Cable (J3, X6DAE-G2/X6DAE-G only) z Control Panel Cable (JF1, see next page) z Front Side USB Cable (JD2) z Floppy Drive Cable (JP8)

Connecting Power Cables

The X6DA8-G2/X6DA8-G/X6DAE-G2/X6DAE-G has a 24-pin primary power supply connector designated "ATX Power" for connection to the ATX power supply.

Connect the appropriate connector from the power supply to the "ATX Power" connector to supply power to the serverboard. The 12V 8-pin power connector at J1D1 and the 12V 4-pin power connector at J32 must also both be connected to your power supply. See the Connector Definitions section in this chapter for power connector pin definitions.

5-5

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Connecting the Control Panel

JF1 contains header pins for various front control panel connectors. See

Figure 5-2 for the pin locations of the various front control panel buttons and

LED indicators. Please note that even and odd numbered pins are on opposite sides of each header.

All JF1 wires have been bundled into single ribbon cable to simplify their connection. Make sure the red wire plugs into pin 1 as marked on the board. The other end connects to the Control Panel printed circuit board, located just behind the system status LEDs in the chassis.

See the Connector Definitions section in this chapter for details and pin descriptions of JF1.

Figure 5-2. JF1 Header Pins

Ground

X

Power LED

HDD LED

NIC1 LED

NIC2 LED*

Overheat LED

Power Fail LED

Ground

Ground

20 19

Vcc

Vcc

Vcc

NMI

X

Vcc

Vcc

Vcc

Reset

Reset Button

Pwr

Power Button

2 1

*NIC2 applies only to the X6DA8-G2 and the X6DAE-G2

5-6

Chapter 5: Advanced Serverboard Setup

5-4 I/O Ports

The I/O ports are color coded in conformance with the PC 99 specification. See

Figure 5-3 below for the colors and locations of the various I/O ports.

USB#0-3

Figure 5-3. I/O Ports

Parallel Port

Line-out

KB/Mouse COM1 COM2 LAN1/2* Line-In

Mic

*Note: The X6DA8-G and X6DAE-G have only a single LAN (Ethernet) port.

5-5 Installing Memory

Note: Check the Supermicro web site for recommended memory modules: http://www.supermicro.com/support/resources/

CAUTION

Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Also note that the memory is interleaved to improve performance (see step 1).

DIMM Installation (See Figures 5-4 and 5-5)

1. Insert the desired number of DIMMs into the memory slots, starting with

Bank #1A. The memory scheme is interleaved so you must install two modules at a time, beginning with DIMM #1A, then DIMM #1B, and so on.

2. Insert each DIMM module vertically into its slot. Pay attention to the notch along the bottom of the module to prevent inserting the DIMM module incorrectly.

3. Gently press down on the DIMM module until it snaps into place in the slot. Repeat for all modules (see step 1 above).

5-7

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Memory Support

The X6DA8-G2/X6DAE-G2 has eight 240-pin DIMMs that support up to 16 GB of registered ECC DDR2-400 (PC3200) SDRAM memory. The X6DA8-G2/X6DAE-

G2 was designed to support 4 GB modules in each slot, but has only been verified for up to 2 GB modules.

The X6DA8-G/X6DAE-G has eight 184-pin DIMMs that support up to 16 GB of registered ECC DDR333 (PC2700) or 32 GB of registered ECC DDR266 (PC2100)

SDRAM memory.

The memory is an interleaved configuration, which requires modules of the same size and speed to be installed in pairs. You should not mix modules of different sizes and/or speeds.

Figure 5-4. Side View of DIMM Installation into Slot

To Install: Insert module vertically and press down until it snaps into place. Pay attention to the bottom notch.

To Remove: Use your thumbs to gently push each release tab outward to free the DIMM from the slot.

Figure 5-5. Top View of DIMM Slot

5-8

Chapter 5: Advanced Serverboard Setup

5-6 Adding PCI Cards

1. PCI slots:

The X6DA8-G2/X6DA8-G/X6DAE-G2/X6DAE-G has has six PCI expansion slots, which includes one x16@4GB/sec PCI-Express slot, one x4@2GB/ sec PCI-Express slot, three 64-bit PCI-X slots (one 64-bit PCI-X 133 slot, one

PCI-X 100 slot, one PCI-X 100MHz ZCR slot) and one 32-bit 33MHz PCI slot

(w/PCI graphics card support).

2. PCI card installation:

Before installing a PCI add-on card, make sure you install it into a slot that supports the speed of the card (see step 1, above). Begin by removing the screw from the PCI slot shield that corresponds to the slot you wish to populate. Insert the PCI card into the slot on the serverboard, pushing down with your thumbs evenly on both sides of the card. Finish by securing the card to the chassis with the same screw you removed from the PCI slot shield. Follow this procedure when adding a card to other slots.

5-9

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

5-7 Serverboard Details

Figure 5-6. SUPER X6DA8-G2/X6DA8-G/X6DAE-G2/X6DAE-G Layout*

(not drawn to scale)

J9

COM1

J 2 3

FAN6

J 4 0

U S B 0 / 1 /

2 / 3

COM2

LAN1/2

J C 2

Line In/Line Out

J C 1 Mic

J P C 1

SI/O

FAN5

J 3 2

ATX PWR

J 1 B 4

DIMM 1B Bank 1

DIMM 1A Bank 1

DIMM 2B Bank 2

DIMM 2A Bank 2

DIMM 3B Bank 3

DIMM 3A Bank 3

DIMM 4B Bank 4

DIMM 4A Bank 4

J P F

P W

Force On

Tumwater

(North Bridge)

Slot #6: x16 PCI-Express

C D 2 C D 1

GLAN

CTRL

J P L 1

Slot #5: PCI (33MHz)

J D 3

Slot #4: x4 PCI-Express

Slot #3: PCI-X (133MHz)

South

Bridge

JBT1

J 2 7

Slot #2: PCI-X (100MHz)

Battery

Slot #4: PCI-X (100MHz ZCR)

JWOR1

JWOL

S P K R

J 2 2

J W D

P X H

FAN7

J 2 4 J 1 D 1

J P 1 2

FAN1

J F 1

CPU1

CPU2

J P 1 5

J D 1

FAN2

JOH1

J L 1

BIOS

J P A 1

J K 1

Keylock

J 2 0

IPMI 2.0

FAN3

FAN8

J P 8

J4 J3

J A 1

AIC-7902

J D 2

J A 2

J P A 2

J P A 3

SCSI Ch B

FAN4

Notes:

Jumpers not noted are for test purposes only.

" " indicates the location of Pin 1.

Only the X6DA8-G2 and X6DA8-G include an onboard SCSI controller.

The X6DA8-G2 and the X6DAE-G2 have two GB LAN ports.

The X6DA8-G and the X6DAE-G have a single GB LAN port.

5-10

Chapter 5: Advanced Serverboard Setup

X6DA8-G2/X6DA8-G/X6DAE-G2/X6DAE-G

Quick Reference

Jumper Description

Default Setting

JBT1

JP13

CMOS Clear See Section 5-9

3rd Pwr Supply Alarm Enable/Disable Open (Disabled)

JPA1* SCSI Controller Enable/Disable Pins 1-2 (Enabled)

JPA2/JPA3* SCSI Ch. A/B Term. Enable/Disable Open(Enabled)

JPC1

JPF

JPL1

JWD

Audio Enable/Disable

Power Force On

Giga-bit LAN Enable/Disable

Watch Dog Enable

Pins 1-2 (Enabled)

Open (Disabled)

Pins 1-2 (Enabled)

Pins 1-2 (Reset)

Connector Description

J1B4

J1D1

COM1, COM2

DIMM1A-4B

FAN1-8

J3/J4

J9

J20

J22

J23

J24

J32

J40

JA1, JA2*

JC1

JC2

Primary 24-pin ATX PWR Connector

12V 8-pin PWR Connector

COM1 and COM2 Serial Port Connectors

Memory (SDRAM) Slots

CPU FAN1/CPU FAN2/Chassis Fans Headers

IDE#1/#2 Disk Drive Connectors

Keyboard/Mouse

IPMI 2.0 Connector

System Management Bus Connector

Parallel (Printer) Port

PWR System Management Bus

12V 4-pin CPU PWR Connector

Universal Serial Bus Ports 0-3 (backpanel ports)

Ultra320 SCSI Channel A, Channel B

Microphone Jack

Line In/Out Jacks

JD1

JD2, JD3

JF1

JK1

JL1

JOH1

JP8

JP12

PWR LED (Pins1-3), Speaker (Pins 4-7)

USB Ports 6/7, 4/5 (front access ports)

Front Panel Control

Keylock

Chassis Intrusion Header

Overheat LED

Floppy Disk Drive Connector

Power Fault Connector

JP14

JWOL

JWOR1

LAN1/2**

*X6DA8-G2/X6DA8-G only

Power Supply Fail Alarm Reset

Wake-on-LAN Header

Wake-on-Ring Header

Gigabit Ethernet Ports

**LAN2 is on the X6DA8-G2/X6DAE-G2 only

5-11

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

5-8 Connector Definitions

ATX Power Connector

The serverboard includes a 24-pin main power supply connector (J1B4) and a 4-pin CPU PWR connector

(J32). These power connectors meet the SSI EPS 12V specification. You can use a 20-pin connector, but connecting J3 is also required to ensure sufficient power. See the table on the right for pin definitions. For CPU power, please see the item below.

ATX Power Supply 24-pin Connector

Pin Definitions (J1B4)

Pin Number Definition Pin Number Definition

13

14

15

16

17

18

19

20

21

22

23

24

+3.3V

-12V

COM

PS_ON#

COM

COM

COM

Res(NC)

+5V

+5V

1 +3.3V

2 +3.3V

3 COM

4 +5V

5 COM

6 +5V

7 COM

8 PWR_OK

9

10

5VSB

+12V

+5V

11

COM 12

+12V

+3.3V

+12V 4-pin Connector

(J32)

Required

Connection

Pins #

1 & 2

3 & 4

Definition

Ground

+12 V

Processor Power

Connector

In addition to the Primary ATX power connector (above), the 12v 8-pin processor power connector at J1D1 must also be connected to your power supply. (If an 8-pin cable is not available, please use two 4-pin cables.) See the table on the right for pin definitions.

Required

Connection

CPU 8-pin PWR

Connector (J1D1)

Pins

1 thru 4

5 thru 8

Definition

Ground

+12v

NMI Button

The non-maskable interrupt button header is located on pins 19 and 20 of JF1. Refer to the table on the right for pin definitions.

Power LED

The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table on the right for pin definitions.

5-12

NMI Button Pin

Definitions (JF1)

Pin

Number

19

20

Definition

Control

Ground

PWR_LED Pin Definitions

(JF1)

Pin

Number

15

16

Definition

Vcc

Control

HDD LED

The HDD LED (for IDE and SCSI Disk

Drives) connection is located on pins

13 and 14 of JF1. Attach the hard drive LED cable to these pins to display disk activity. Refer to the table on the right for pin definitions.

Chapter 5: Advanced Serverboard Setup

HDD LED Pin

Definitions

(JF1)

Pin

Number

13

14

Definition

Vcc

HD Active

NIC LEDs

The NIC (Network Interface Controller) LED connections for the GLAN port1 is located on pins 11 and 12 of

JF1 and the NIC LED connections for

GLAN port 2 are located on pins 9 and 10 of JF1. Attach the NIC1 LED cable to display network activity.

Refer to the table on the right for pin definitions.

Overheat LED (OH)

Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide warning of a processor overheating.

The LED will blink as long as an overheat condition exists. Refer to the table on the right for pin definitions.

Power Fail LED

The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin definitions.

5-13

NIC LED Pin

Definitions

(JF1)

Pin

Number

9/11

10/12

Definition

Vcc

GND

Overheat (OH) LED

Pin Definitions

(JF1)

Pin

Number

7

8

Definition

Vcc

GND

Power Fail LED Pin

Definitions

(JF1)

Pin

Number

5

6

Definition

Vcc

GND

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Reset Button

The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to the hardware reset switch on the computer case. Refer to the table on the right for pin definitions.

Reset Pin

Definitions

(JF1)

Pin

Number

3

4

Definition

Reset

Ground

Power Button

The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins will power on/off the system. This button can also be configured to function as a suspend button (see the appropriate setting in BIOS). To turn off the power when set to suspend mode, depress the button for at least 4 seconds. Refer to the table on the right for pin definitions.

Power Button

Connector

Pin Definitions

(JF1)

Pin

Number

1

2

Definition

PW_ON

Ground

Chassis Intrusion

A Chassis Intrusion header is located at JL1. Attach the appropriate cable to inform you of a chassis intrusion.

Chassis Intrusion

Pin Definitions (JL1)

Pin

Number

1

2

Definition

Intrusion Input

Ground

Universal Serial Bus

(USB0/1)

USB Pin Definitions

J40 (Back Panel USB)

There are eight USB 2.0 (Universal

Serial Bus) ports/headers on the motherboard. Four of them are back panel USB ports (USB0-3 at J40), and the other four are front panel

USB headers (USB4/5:JD3 and

USB6/7: JD2). See the tables on the right for pin definitions.

5-14

Pin# Definition

1 +5V

2 P0-

3 P0+

4 Ground

Pin

Number

5

7

1

3

JD2 & JD3 (FP USB)

Definition

+5V

PO-

PO+

Ground

Pin

Number

2

4

6

8

10

Definition

+5V

PO-

PO+

Ground

Ground

Fan Headers

There are eight fan headers (FAN1-

FAN8) on the X6DA8-G2/X6DAE-G2.

See the table on the right for pin definitions. (Note: These fan headers are

4-pin fans. Pins 1-3 are backward compatible with traditional 3-pin fans.)

Chapter 5: Advanced Serverboard Setup

Fan Header Pin Definitions

Pin #

1

2

3

4

Definition

Ground (black)

+12V (red)

Tachometer

PWR_Control

Caution: These fan headers

use DC power.

Serial Ports

The COM1 (J3) and COM2 (J4) serial ports are located under the parallel port (see Figure 2-3). See the table on the right for pin definitions.

Serial Port Pin Definitions

(COM1, COM2)

Pin Number Definition

1 CD

2

3

RD

TD

4

5

DTR

Ground

Pin Number Definition

6

7

8

9

10

DSR

RTS

CTS

RI

NC

Note: Pin 10 is included on the header but not on the port.

GLAN1/2 (Ethernet Ports)

Two Gigabit Ethernet ports (designated LAN1 and LAN2) are located on the I/O backplane. These ports accept RJF1 type cables.

ATX PS/2 Keyboard and

PS/2 Mouse Ports

The ATX PS/2 keyboard and PS/2 mouse are located on J9. See the table at right for pin definitions.

(See Figure 5-3 for the locations of each.)

5-15

PS/2 Keyboard and Mouse Port

Pin Definitions

(J9)

Pin

Number

1

2

3

4

5

6

Definition

Data

NC

Ground

VCC

Clock

NC

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Power LED/Speaker/NMI

On the JDI header, pins 1-3 are for a power LED and pins 4-7 are for the speaker. See the table on the right for speaker pin definitions.

Note: The speaker connector pins are for use with an external speaker.

If you wish to use the onboard speaker, you should close pins 6-7 with a jumper.

Wake-On-Ring

The Wake-On-Ring header is designated JWOR1. This function allows your computer to receive and "wakeup" by an incoming call to the modem when in suspend state. See the table on the right for pin definitions. You must have a Wake-On-

Ring card and cable to use this feature.

Speaker Connector Pin

Definitions (JD1)

Pin

Number

4

5

6

7

Function

+

Key

Definition

Red wire, Speaker data

No connection

Key

Speaker data

Wake-on-Ring

Pin Definitions

(JWOR1)

Pin

Number

1

2

Definition

Ground

W ake-up

Wake-On-LAN

The Wake-On-LAN header is located at JWOL on the motherboard. See the table on the right for pin definitions. You must enable the LAN

Wake-Up setting in BIOS to use this function. (You must also have a LAN card with a Wake-On-LAN connector and cable to use this feature.)

Wake-On-LAN Pin

Definitions (JWOL)

Pin

Number

1

2

3

Definition

+5V Standby

Ground

Wake-up

SMB

A System Management Bus header is located at J22. Connect the appropriate cable here to utilize SMB on your system.

5-16

SMB Header

Pin Definitions (J22)

Pin

Number

1

2

3

4

Definition

Data

Ground

Clock

No Connection

Power Fault

Connect a cable from your power supply to the Power Fail header

(JP12) to provide warning of power supply failure. This warning signal is passed through the PWR_LED pin to indicate of a power failure on the chassis. See the table on the right for pin definitions.

Chapter 5: Advanced Serverboard Setup

Power Fail

Pin Definitions (JP12)

Pin

Number

1

2

3

4

Definition

P/S 1 Fail Signal

P/S 2 Fail Signal

P/S 3 Fail Signal

Reset (from MB)

Note: This feature is only available when using redundant Supermicro power supplies.

Keylock

The keyboard lock connection is located on JK1. Utilizing this header allows you to inhibit any actions made on the keyboard, effectively "locking" it.

Power Supply Fail Alarm

Reset

If three power supplies are installed and JP14 is enabled, the system will notify you if any of the three power modules fail. Connect jumper JP13 to a microswitch to enable you to turn off the alarm that sounds when a power module fails. See the table on the right for pin definitions.

Power Supply Fail

Alarm Reset

Pin Definitions

(JP13)

Pin

Number

2

1

Definition

+5V

Ground

5-17

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

5-9 Jumper Settings

Explanation of

Jumpers

To modify the operation of the serverboard, jumpers can be u s e d t o c h o o s e b e t w e e n o p t i o n a l s e t t i n g s . J u m p e r s create shorts between two pins to change the function of the connector. Pin 1 is identified w i t h a s q u a r e s o l d e r p a d o n the printed circuit board. See the serverboard layout pages for jumper locations.

N o t e : O n t w o p i n j u m p e r s ,

"Closed" means the jumper is on and "Open" means the jumper is off the pins.

Connector

Pins

Jumper

Cap

Setting

3 2 1

3 2 1

Pin 1-2 short

CMOS Clear

JBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins, this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS.

To clear CMOS,

1) First unplug the power cord(s)

2) With the power disconnected, short the CMOS pads with a metal object such as a small screwdriver

3) Remove the screwdriver (or shorting device)

4) Reconnect the power cord(s) and power on the system.

Note: Do not use the PW_ON connector to clear CMOS.

5-18

GLAN Enable/Disable

Change the setting of jumper JPL1 to enable or disable the onboard GLAN ports (GLAN1 and GLAN2) on the serverboard. See the table on the right for jumper settings. The default setting is enabled

Chapter 5: Advanced Serverboard Setup

GLAN

Enable/Disable

Jumper Settings

(JPL1)

Jumper

Position

Pins 1-2

Pins 2-3

Definition

Enabled

Disabled

SCSI Controller Enable/

Disable (X6DA8-G2/X6DA8-G only)

Jumper JPA1 allows you to enable or disable the SCSI headers. The default setting is pins 1-2 to enable all four headers. See the table on the right for jumper settings.

SCSI Enable/Disable

Jumper Settings

(JPA1)

Jumper

Position

Pins 1-2

Pins 2-3

Definition

Enabled

Disabled

SCSI Termination Enable/

Disable (X6DA8-G2/X6DA8-G only)

Jumpers JPA2 and JPA3 allow you to enable or disable termination for the

SCSI connectors. Jumper JPA2 controls SCSI channel A and JPA3 is for channel B. The default setting is open to enable (terminate) both SCSI channels.

Note: In order for the SCSI drives to function properly, please do not change the default setting set by the manufacturer. See the table on the right for jumper settings.

5-19

SCSI Channel Termination

Enable/Disable

Jumper Settings

(JPA2, JPA3)

Jumper

Position

Open

Closed

Definition

Enabled

Disabled

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Watch Dog Enable/Disable

JWD enables the Watch Dog function. Watch Dog is a system monitor that can reboot the system when a software application is "hung up".

Pins 1-2 will cause WD to reset the system if an application is hung up.

P i n s 2 - 3 w i l l g e n e r a t e a n o n maskable interrupt signal for the application that is hung up. See the table on the right for jumper settings.

Watch Dog can also be enabled via

BIOS.

Note: When enabled, the user needs to write his own application software in order to disable the Watch Dog

Timer.

Watch Dog

Jumper Settings (JWD)

Jumper

Position

Pins 1-2

Pins 2-3

Open

Definition

WD to Reset

WD to NMI

Disabled

AC'97 Audio Enable/Disable

AC'97 provides high quality onboard audio. The serverboard features 6-channel sound for front L&R, rear L&R, center and subwoofer speakers. This feature is activated with the Advanced software on t h e C D - R O M i n c l u d e d w i t h y o u r motherboard. The Line In, Line Out and

MIC jacks (see at right) may then be used. Activate AC 97 with the "AC 97

Audio" setting in the Advanced Chipset

Features section of BIOS. To activate the Onboard Audio, please enable the

Jumper JPC1. See the table on right for pin definitions.

AC97 Enable/Disable

Jumper Settings (JPC1)

Jumper

Position

1-2

2-3

Definition

Enabled

Disabled

Blue: Line In (surround sound L/R)

Green: Line Out

(front L/R)

Pink: MIC In (center/ subwoofer)

5-20

3rd Power Supply Alarm

Enable/Disable

The system can notify you in the event of a power supply failure. This feature assumes that three power supply units are installed in the c h a s s i s w i t h o n e a c t i n g a s a backup. If you only have one or two power supply units installed, you should disable this (the default setting) with JP14 to prevent false alarms. See the table on right for pin definitions.

Chapter 5: Advanced Serverboard Setup

Power Supply

Alarm Enable/Disable

Jumper Settings (JP14)

Jumper

Position

Open

Closed

Definition

Disabled

Enabled

Power Force On Enable/

Disable

Jumper JPF allows you to enable or disable the Power Force On function.

If enabled, the power will always stay on automatically. If this function disabled, the user needs to press the power button to power on the system.

Force Power On

(JPF)

Jumper

Position

Open

Closed

Definition

Normal

Force On

5-21

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

5-10 Onboard Indicators

GLAN1/GLAN2 LEDs

Each of the Ethernet ports (located beside the VGA port) have two

LEDs. The yellow LED indicates activity while the other LED may be green, orange or off to indicate the speed of the connection. See the table on the right for the functions associated with this second

LED.

1 Gb LAN Right LED

Indicator

LED

Color

Off

Green

Orange

Definition

No Connection

100 MHz

1 GHz

5-11 Parallel Port, Floppy/Hard Disk Drive and SCSI

Connections

Note the following when connecting the floppy and hard disk drive cables:

• The floppy disk drive cable has seven twisted wires.

• A red mark on a wire typically designates the location of pin 1.

• A single floppy disk drive ribbon cable has 34 wires and two connectors to provide for two floppy disk drives. The connector with twisted wires always connects to drive A, and the connector that does not have twisted wires always connects to drive B.

Parallel (Printer) Port

Connector

The parallel (printer) port is located on J23. See the table on the right for pin definitions.

Parallel (Printer) Port Pin Definitions

(J23)

Pin Number Function

1 Strobe-

3

5

7

9

Data Bit 0

Data Bit 1

Data Bit 2

Data Bit 3

Pin Number

2

4

6

8

10

Function

Auto Feed-

Error-

Init-

SLCT IN-

GND

11

13

15

17

19

Data Bit 4

Data Bit 5

12

14

Data Bit 6

Data Bit 7

ACK

16

18

20

GND

GND

GND

GND

GND

21

23

25

BUSY

PE

SLCT

22

24

26

GND

GND

NC

5-22

Chapter 5: Advanced Serverboard Setup

Floppy Connector

The floppy connector is located on

JP8. See the table below for pin definitions.

Floppy Connector Pin Definitions (JP8)

Pin Number Function

1 GND

3

5

GND

Key

7

9

11

13

15

17

19

21

23

GND

GND

GND

GND

GND

GND

GND

GND

GND

25

27

29

31

33

GND

GND

GND

GND

GND

Pin Number

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

Function

FDHDIN

Reserved

FDEDIN

Index-

Motor Enable

Drive Select B-

Drive Select A-

Motor Enable

DIR-

STEP-

Write Data-

Write Gate-

Track 00-

Write Protect-

Read Data-

Side 1 Select-

Diskette

IDE Connectors

T h e r e a r e n o j u m p e r s t o configure the onboard IDE#1 and #2 connectors. See the table on the right for pin definitions.

25

27

29

31

33

35

37

39

Pin Number

1

3

5

7

9

11

13

15

17

19

21

23

IDE Connector Pin Definitions

(J3, J4)

Function

Reset IDE

Host Data 7

Host Data 6

Host Data 5

Host Data 4

Host Data 3

Host Data 2

Host Data 1

Host Data 0

GND

DRQ3

I/O Write-

I/O Read-

IOCHRDY

DACK3-

IRQ14

Addr 1

Addr 0

Chip Select 0

Activity

Pin Number

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

Function

GND

Host Data 8

Host Data 9

Host Data 10

Host Data 11

Host Data 12

Host Data 13

Host Data 14

Host Data 15

Key

GND

GND

GND

BALE

GND

IOCS16-

GND

Addr 2

Chip Select 1-

GND

5-23

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Ultra320 SCSI Connectors

(X6DA8-G2/X6DA8-G only)

Refer to the table below for the pin definitions of the Ultra320 SCSI connectors located at JA1 and JA2.

Connector

Contact

Number

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

11

12

13

14

15

16

17

18

19

7

8

9

10

3

4

5

6

1

2

Ultra320 SCSI Connectors (JA1, JA2)

Signal Names

Connector

Contact

Number Signal Names

GROUND

+ATN

GROUND

+BSY

+ACK

+RST

+MSG

+SEL

+C/D

+REQ

+I/O

+DB(8)

+DB(9)

+DB(10)

+DB(11)

+DB(12)

+DB(13)

+DB(14)

+DB(15)

+DB(P1)

+DB(0)

+DB(1)

+DB(2)

+DB(3)

+DB(4)

+DB(5)

+DB(6)

+DB(7)

+DB(P)

GROUND

DIFFSENS

TERMPWR

TERMPWR

RESERVED

GROUND

-ATN

GROUND

-BSY

-ACK

-RST

-MSG

-SEL

-C/D

-REQ

-I/O

-DB(8)

-DB(9)

-DB(10)

-DB(11)

-DB(12)

-DB(13)

-DB(14)

-DB(15)

-DB(P1)

-DB(0)

-DB(1)

-DB(2)

-DB(3)

-DB(4)

-DB(5)

-DB(6)

-DB(7)

-DB(P)

GROUND

GROUND

TERMPWR

TERMPWR

RESERVED

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

45

46

47

48

49

50

51

52

53

41

42

43

44

35

36

37

38

39

40

5-24

Chapter 6: Advanced Chassis Setup

Chapter 6

Advanced Chassis Setup

This chapter covers the steps required to install components and perform simple maintenance on the SC743S1-645/SC743i-645 chassis. Following the component installation steps in the order given will eliminate most common problems.

If some steps are unnecessary, skip ahead to the step that follows. Refer to

Chapter 2 for instructions on installing the system as a 4U rackmount.

Tools Required

The only tool you will need is a Philips screwdriver.

6-1 Static-Sensitive Devices

Static electrical discharge can damage electronic components. To prevent damage to any printed circuit boards (PCBs), it is important to handle them very carefully. The following measures are generally sufficient to protect your equipment from static discharge.

Precautions

• Use a grounded wrist strap designed to prevent static discharge.

• Touch a grounded metal object before removing any board from its antistatic bag.

• Handle a board by its edges only; do not touch its components, peripheral chips, memory modules or gold contacts.

• When handling chips or modules, avoid touching their pins.

• Put the serverboard, add-on cards and peripherals back into their antistatic bags when not in use.

• For grounding purposes, make sure your computer chassis provides excellent conductivity between the power supply, the case, the mounting fasteners and the serverboard.

Unpacking

The serverboard is shipped in antistatic packaging. When unpacking the board, make sure the person handling it is static protected.

6-1

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Figure 6-1. Chassis Front View

Main Power System Reset

System LEDs USB Ports

5.25" Drive Bays (2)

Floppy Drive

8 SCSI Drive Bays (7044A-

82/7044A-8 only)

2 IDE Drive Carriers, 4 hard drives each (7044Ai2/7044A-i only)

6-2

Chapter 6: Advanced Chassis Setup

6-2 Front Control Panel

The front control panel must be connected to the JF1 connector on the serverboard to provide you with system status and alarm indications. A ribbon cable has bundled these wires together to simplify this connection.

Connect the cable from JF1 on the serverboard (making sure the red wire plugs into pin 1) to the appropriate comnnector on the front control panel

PCB (printed circuit board). Pull all excess cabling over to the control panel side of the chassis. The LEDs on the control panel inform you of system status - see Figure 6-2 for details. See Chapter 5 for details on JF1.

Power

Figure 6-2. Front Control Panel LEDs

Indicates power is being supplied to the system.

HDD

NIC

NIC

Overheat

Power Fail

Indicates IDE device and hard drive activity. On the

7044A-82/7044A-8, this LED indicates SCSI hard drive activity when flashing. On the 7044A-i2/7044A-i, this

LED indicates IDE hard drive activity when flashing.

Indicates network activity on GLAN port 1.

Indicates network activity on GLAN port 2 (7044A-82/

7044A-i2 only).

When this LED flashes, it indicates a fan failure. When on continuously it indicates an overheat condition (see

Chapter 3 for details).

Non-applicable (for redundant power supply systems only).

6-3

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

6-3 System Fans

Four 8-cm chassis cooling fans (located in the center of the chassis) provide cooling airflow. The chassis is fitted with an air shroud to concentrate the flow of cooling air over the areas of highest generated heat. The fans should all be connected to headers on the serverboard (see Chapter 5). The power supply module also has a cooling fan.

Fan Failure

Under normal operation, all four chassis fans and the power supply fan run continuously. The four chassis cooling fans (not the power supply fan) are hotswappable and can be replaced without powering down the system.

Replacing System Fans

1.

Identifying the failed fan:

To locate and replace a failed chassis fan, begin by removing the top/left chassis cover (see Chapter 2 for details on removing the cover).

2.

Removing a hot-plug fan housing:

Depress the locking tab on a chassis cooling fan and pull the unit straight out by the handle (see Figure 6-3). The fan wiring for these fans has been designed to detach automatically.

3.

Installing a new system fan:

Replace the failed fan with an identical one (available from Supermicro).

Install and reassemble it in the fan housing then plug the housing back into its slot; it should click into place when fully inserted. Check that the fan is working properly and replace the top/left side chassis panel.

Removing the air shroud:

Under most circumstances you will not need to remove the air shroud to perform any service on the system. However, if you wish to temporarily remove it (the air shroud sould always be in place when the system is operating), please follow this procedure. Begin by depressing the tabs at the front and rear of the shroud to unlock it, then lift it up and out of the chassis

(see Figure 6-4). To reinstall, simply position the air shroud in its proper place and push it in until you hear it click.

6-4

Chapter 6: Advanced Chassis Setup

Figure 6-3. Removing a Chassis Fan

Figure 6-4. Removing the Air Shroud

6-5

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

6-4 Drive Bay Installation

SCSI Drives (7044A-82/7044A-8 only)

Eight SCSI drives may be housed in the SC743S1-645chassis. The SCSI drive IDs are preconfigured as 0 through 7 in order from right to left (or from bottom to top if rackmounted).

Note: You must use standard 1" high, 80-pin SCA SCSI drives in the

SuperWorkstation 7044A-82/7044A-8.

!

Use extreme caution when working around the SCSI backplane.

Do not touch the backplane with any metal objects and make sure no ribbon cables touch the backplane or obstruct the airflow.

1.

Installing/removing hot-plug SCSI drives:

The eight SCSI drive carriers are all easily accessible at the front of the chassis. The SCSI drives are hot-pluggable, meaning they can be removed and installed without powering down the system. To remove a carrier, first push the release button located beside the drive LEDs. Swing the colored handle fully out and use it to pull the unit straight out (see Figure 6-5).

Note: Your operating system must have RAID support to enable the hot-plug capability of the SCSI drives.

2.

Mounting a SCSI drive in a drive carrier:

The SCSI drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also work to promote proper airflow for the system. For this reason, even carriers without

SCSI drives must remain in the server. If you need to add a new SCSI drive, insert the drive into the carrier with the printed circuit board side facing down so that the mounting holes align with those in the carrier.

Secure the drive to the carrier with four screws. (See Figure 6-6.)

6-6

Chapter 6: Advanced Chassis Setup

Figure 6-5. Removing a SCSI Drive Carrier

Figure 6-6. Mounting a SCSI Drive in a Carrier

!

Important: Regardless of how many SCSI hard drives are installed, all SCSI drive carriers must remain in the drive bays to promote proper airflow.

3.

SCSI backplane:

All eight SCSI drives plug into a single SCSI backplane, which provides

Ultra320 single channel operation for all eight SCSI drives. A ribbon cable from JA1 on the serverboard should be connected to the IN connector on the

SCSI backplane. There is also a power connector on the backplane that must be connected. See Figure 6-7 for the locations of backplane connectors - the reverse side of the backplane has five connectors that the SCSI drives plug into when inserted with a SCSI drive carrier or mobile rack.

6-7

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Figure 6-7. SCSI Backplane

Power Connector

SCSI LVD Connector

Jumper Settings

JP19: Buzzer Enable, Closed (On) Enabled (default), Open (Off): Disabled

LEDs

Drive Fail LEDs: Fail1, Fail2, Fail3, Fail4, Fail5, Fail6, Fail7, Fail8

Activity LEDs: ACT1, ACT2, ACT3, ACT4, ACT5, ACT6, ACT7, ACT8

6-8

Chapter 6: Advanced Chassis Setup

Installing Components in the 5.25" Drive Bays

1.

Drive bay configuration

The 7044A-82/7044A-i2 has two 5.25" drive bays. Components such as an extra floppy drive, IDE hard drives or CD-ROM drives can be installed in these

5.25" drive bays.

2.

Mounting components in the drive bays

First power down the system and then remove the top/left chassis cover to access the drive components. With the cover off, remove the two or four screws that secure the drive carrier to the chassis (one side only) then push the entire empty drive carrier out from the back.

Adding a CD-ROM drive: remove the guide plate from right side of the empty drive carrier and screw it into the right side of the CD-ROM drive using the holes provided (see Figure 6-8). Then slide the CD-ROM into the bay and secure it to the chassis with the drive carrier screws you first removed. Attach the power and data cables to the drive. Replace the top/left chassis cover before restoring power to the system.

Adding an IDE or floppy drive: to add one of these drives, install it into one of the removed empty drive carriers with the printed circuit board side toward the carrier so that the drive's mounting holes align with those in the carrier.

Secure the drive to the carrier with four screws then slide the assembly into the bay and secure it to the chassis with the drive carrier screws you first removed. Attach the power and data cables to the drive. Replace the top/left chassis cover before restoring power to the system.

Note: A red wire typically designates the location of pin 1. You should keep the drive carriers inserted in any unused drive bays to reduce EMI and noise and to facilitate the airflow inside the chassis.

Figure 6-8. Adding a Component Without a Drive Carrier

6-9

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

6-5 Power Supply

The SuperWorkstation 7044A-82/7044A-8/7044A-i2/7044A-i has a single 645 watt power supply. This power unit is equipped with low-noise technology, making the system ideal for workstation environments.

The power supply has an auto-switching capability that enable it to automatically sense and operate with 100 or 240 volt inputs. The power module is

PFC (Power Factor Correction) compliant.

Power Supply Failure

If the power supply unit fails, the system will shut down and you will need to replace the unit. Replacement units can be ordered directly from Supermicro

(see contact information in the Preface). As there is only one power supply unit in the 7044A-82/7044A-8/7044A-i2/7044A-i, power must be completely removed from the server before removing and replacing the power supply unit for whatever reason.

Replacing the Power Supply

1.

Accessing the power supply:

For safety reasons, you will need to remove power from the system when replacing the power supply on the 7044A-82/7044A-8/7044A-i2/7044A-i. The power supply can be removed from the back of the chassis; access to the inside is unnecessary.

2.

Removing the power supply:

First, unplug the power cord from the failed power supply. Then press the locking tab on the module and pull the unit completely out.

3.

Installing a new power supply module:

Replace the failed unit with another unit of the same input voltage, output voltage and wattage. It is highly recommended to replace it with exactly the same model power supply (PWS-0060). Gently but firmly push the new unit all the way into the open bay. Secure it to the chassis using the locking tab. Plug the power cord back into the new power supply. Finish by depressing the power button on the chassis front control panel.

6-10

Chapter 7: BIOS

Chapter 7

BIOS

7-1 Introduction

This chapter describes the Phoenix BIOS™ Setup utility for the X6DA8-G2/

X6DA8-G/X6DAE-G2/X6DAE-G. The Phoenix ROM BIOS is stored in a flash chip and can be easily upgraded using a floppy disk-based program.

Note: Due to periodic changes to the BIOS, some settings may have been added or deleted and might not yet be recorded in this manual. Please refer to the

Manual Download area of the Supermicro web site (http://www.supermicro.com) for any changes to the BIOS that may not be reflected in this manual.

System BIOS

The BIOS is the Basic Input Output System used in all IBM

®

PC, XT™, AT

®

, and

PS/2

®

compatible computers. The Phoenix BIOS flash chip stores the system parameters, such type of disk drives, video displays, etc. in the CMOS. The

CMOS memory requires very little electrical power. When the computer is turned off, a back-up battery provides power to the BIOS flash chip, enabling it to retain system parameters. Each time the computer is powered-on the computer is configured with the values stored in the BIOS ROM by the system BIOS, which gains control at boot-up.

How To Change the Configuration Data

The CMOS information that determines the system parameters may be changed by entering the BIOS Setup utility. This Setup utility can be accessed by pressing the <Delete> key at the appropriate time during system boot, see below.

Starting the Setup Utility

Normally, the only visible POST (Power On Self Test) routine is the memory test.

As the memory is being tested, press the <Delete> key to enter the main menu of the BIOS Setup utility. From the main menu, you can access the other setup screens, such as the Security and Power menus. Beginning with Section 7-3, detailed descriptions are given for each parameter setting in the Setup utility.

7-1

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

7-2 Running Setup

*Default settings are in bold text unless otherwise noted.

The BIOS setup options described in this section are selected by choosing the appropriate text from the main BIOS Setup screen. All displayed text is described in this section, although the screen display is often all you need to understand how to set the options (see on next page).

When you first power on the computer, the Phoenix BIOS™ is immediately activated.

While the BIOS is in control, the Setup program can be activated in one of two w a y s :

1.

By pressing <Delete> immediately after turning the system on, or

2.

When the message shown below appears briefly at the bottom of the screen during the POST (Power On Self-Test), press the <Delete> key to activate the main Setup menu:

Press the <Delete> key to enter Setup

7-3 Main BIOS Setup

All main Setup options are described in this section. The main BIOS Setup screen is displayed below.

Use the Up/Down arrow keys to move among the different settings in each menu.

Use the Left/Right arrow keys to change the options for each setting.

Press the <Esc> key to exit the CMOS Setup Menu. The next section describes in detail how to navigate through the menus.

Items that use submenus are indicated with the icon. With the item highlighted, press the <Enter> key to access the submenu.

7-2

Main BIOS Setup Menu

Chapter 7: BIOS

Main Setup Features

System Time

To set the system date and time, key in the correct information in the appropriate fields. Then press the <Enter> key to save the data.

System Date

Using the arrow keys, highlight the month, day and year fields and enter the correct data. Press the <Enter> key to save the data.

BIOS Date

This feature allows the BIOS to automatically display the BIOS date.

7-3

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Legacy Diskette A

This setting allows the user to set the type of floppy disk drive installed as diskette A. The options are Disabled, 360Kb 5.25 in, 1.2MB 5.25 in, 720Kb

3.5 in, 1.44/1.25MB, 3.5 in and 2.88MB 3.5 in.

Parallel ATA

This setting allows the user to enable or disable the funciton of Parallel

ATA. The options are Disabled, Channel 0, Channel 1 and Both.

Serial ATA

This setting allows the user to enable or disable the funciton of Serial ATA.

The options are Disabled and Enabled.

Serial ATA RAID Enable

Select Enable to enable Serial ATA RAID Functions. (*For the Windows OS environment, use the RAID driver if this feature is set to Enabled. If

Disabled, use the "Non-RAID" driver.)

Native Mode Operation

This option allows the user to select the Native Mode for ATA. Some

Operating Systems are not supported by the Native Mode. The options are:

Serial ATA, Parallel ATA, Auto, and Both.

IDE Channel 0 Master/Slave, IDE Channel 1 Master/Slave, IDE

Channel 2 Master, IDE Channel 3 Master

These settings allow the user to set the parameters of IDE Channel 0

Master/Slave, IDE Channel 1 Master/Slave, IDE Channel 2 Master, IDE

Channel 3 Master slots. Hit <Enter> to activate the following sub-menu screen for detailed options of these items. Set the correct configurations accordingly. The items included in the sub-menu are:

7-4

Chapter 7: BIOS

Type

Selects the type of IDE hard drive. The options are Auto (allows the

BIOS to automatically determine the hard drive's capacity, number of heads, etc.), a number from 1-39 to select a predetermined type of hard drive, CD-ROM and ATAPI Removable. The option- "User" will allow the user to enter the parameters of the HDD installed at this connection. The o p t i o n - " A u t o " w i l l a l l o w t h e B I O S t o a u t o m a t i c a l l y c o n f i g u r e t h e parameters of the HDD installed at the connection. Choose the option"1-

39" to select a pre-determined HDD type. Select CD-ROM if a CD-ROM drive is installed. Select ATAPI if a removable disk drive is installed.

Multi-Sector Transfers

Select the number of transfer sectors. The options are Disabled, 2, 4, 6,

8 and 16 Sectors.

7-5

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

LBA Mode Control

T h i s i t e m d e t e r m i n e s w h e t h e r T h e P h o e n i x B I O S w i l l a c c e s s t h e

IDEChannel 0 Master Device via the LBA mode. The options are Disabled and Enabled.

32 Bit I/O

This option allows the user to enable or disable the function of 32-bit datea transfer. The options are Enabled and Disabled.

Transfer Mode

Selects the transfer mode. The options are Standard, Fast PIO1, Fast

PIO2, Fast PIO3, Fast PIO4, FPIO3/DMA1 and FPIO4/DMA2.

Ultra DMA Mode

Selects Ultra DM A Mode. The options are Disabled, Mode 0, Mode 1,

Mode 2, Mode 3, Mode 4 and Mode 5.

System Memory

This display informs you how much system memory is recognized as being present in the system.

Extended Memory

This display informs you how much extended memory is recognized as being present in the system.

7-6

Chapter 7: BIOS

7-4 Advanced Setup

Choose Advanced from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. The items with a triangle beside them have sub menus that can be accessed by highlighting the item and pressing

<Enter>. Options for PIR settings are displayed by highlighting the setting option using the arrow keys and pressing <Enter>. All Advanced BIOS Setup options are described in this section.

Boot Features

Access the submenu to make changes to the following settings.

Quick Boot Mode

If enabled, this feature will speed up the POST (Power On Self Test) routine by skipping certain tests after the computer is turned on. The settings are Enabled and Disabled. If Disabled, the POST routine will run at normal speed.

Quiet Boot

This setting allows you to Enable or Disable the diagnostic screen during boot-up.

7-7

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

ACPI Mode

Use the setting to determine if you want to employ ACPI (Advanced

Configuration and Power Interface) power management on your system.

The options are Yes and No.

ACPI Sleep Mode

Selects the sleep mode for ACPI. The options are S1(-Stanby) and S3

(-Suspend to RAM).

Power Loss Control

This setting allows you to choose how the system will react when power returns after an unexpected loss of power. The options are Stay Off,

Power On and Last State.

Watch Dog

This setting is for enabling the Watch Dog feature. The The options are

Enabled and Disabled.

Summary Screen

This setting allows you to Enable or Disable the summary screen which displays the system configuration during bootup.

Memory Cache

Cache System BIOS Area

This setting allows you to designate a reserve area in the system memory to be used as a System BIOS buffer to allow the BIOS write

(cache) its data into this reserved memory area. Select "Write Protect" to enable this function, and this area will be reserved for the BIOS ROM access only. Select "Uncached" to disable this function and make this area available for other devices.

Cache Video BIOS Area

This setting allows you to designate a reserve area in the system memory to be used as a Video BIOS buffer to allow the BIOS write

(cache) its data into this reserved memory area. Select "Write Protect"

7-8

Chapter 7: BIOS to enable the function and this area will be reserved for the BIOS ROM access only. Select "Uncached" to disable this function and make this area available for other devices.

Cache Base 0-512K

If enabled, this feature will allow the data stored in the base memory area: block 0-512K to be cached (written) into a buffer, a storage area in the Static DRM (SDROM) or written into L1, L2, L3 cache inside the

CPU to speed up CPU operations . Select "Uncached" to disable this funciton. Select "Write Through" to allow data to be cached into the buffer and written into the system memory at the same time. Select

"Write Protect" to prevent data from being written into the base memory area of Block 0-512K. Select "Write Back" to allow CPU to write data back directly from the buffer without writing data to the System Memory f o r f a s t C P U d a t a p r o c e s s i n g a n d o p e r a t i o n . T h e o p t i o n s a r e

"Uncached", "Write Through", "Write Protect", and "Write Back".

Cache Base 512K-640K

If enabled, this feature will allow the data stored in the memory area:

512K-640K to be cached (written) into a buffer, a storage area in the

Static DRM (SDROM) or written into L1, L2, L3 cache inside the CPU to speed up CPU operations . Select "Uncached" to disable this funciton.

Select "Write Through" to allow data to be cached into the buffer and written into the system memory at the same time. Select "Write Protect" to prevent data from being written into the base memory area of Block

0-512K. Select "Write Back" to allow CPU to write data back directly from the buffer without writing data to the System Memory for fast CPU data processing and operation. The options are "Uncached", "Write Through",

"Write Protect", and "Write Back".

Cache Extended Memory

If enabled, this feature will allow the data stored in the extended memory area to be cached (written) into a buffer, a storage area in the Static

DRM (SDROM) or written into L1, L2, L3 cache inside the CPU to speed up CPU operations . Select "Uncached" to disable this funciton. Select

"Write Through" to allow data to be cached into the buffer and written into the system memory at the same time. Select "Write Protect" to prevent data from being written into the base memory area of Block 0-

7-9

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

512K. Select "Write Back" to allow CPU to write data back directly from the buffer without writing data to the System Memory for fast CPU data processing and operation. The options are "Uncached", "Write Through",

"Write Protect", and "Write Back".

PCI Configuration

Access the submenu to make changes to the following settings for PCI devices.

Onboard GLAN (Gigabit- LAN) OPROM Configure

Enabling this option provides the capability to boot from GLAN. The options are Enabled and Disabled.

Onboard SCSI OPROM Configure

Enabling this option provides the caability to boot from SCSI HDD. The options are Disabled and Enabled.

Reset Configuration Data

If set to Yes, this setting clears the Extended System Configuration Data-

(ESCD) area. The options are Yes and No.

Frequency for PCIX#1-#2/SCSI

This option allows the user to change the bus frequency for the devices installed in the slot indicated. The options are Auto, PCI 66 MHz, PCI-X

66 MHz, PCI-X 100 MHz, and PCI-X 133 MHz.

Frequency for PCIX#1/G-LAN

This option allows the user to change the bus frequency of the devices installed in the slot indicated. The options are Auto, PCI 66 MHz, PCI-X

66 MHz, PCI-X 100 MHz, and PCI-X 133 MHz.

PCI Devices, Slot #1 - Slot#6

Access the submenu for each of the settings above to make changes to the following:

7-10

Chapter 7: BIOS

Option ROM Scan

When enabled, this setting will initialize the device expansion ROM.

The options are Enabled and Disabled.

Enable Master

This setting allows you to enable the selected device as the PCI bus master. The options are Enabled and Disabled.

Latency Timer

This setting allows you to set the clock rate for Bus Master.A highprioity, high-throughout device may benefit from a greater Clock rate.

The options are Default, 0020h, 0040h, 0060h, 0080h, 00A0h, 00C0h, and 00E0h. For Unix, Novell and other Operating Systems, please select the option:"other". If a drive fails after the installation of a new software , you might want to change this settiing and try again.

Different OS requires different Bus Master clock rate.

Large Disk Access Mode

This setting determines how large hard drives are to be accessed. The options are DOS or Other (for Unix, Novellle NetWare and other operating systems).

Advanced Chipset Control

Access the submenu to make changes to the following settings.

Force Compliance Mode

If enabled, this feature sets the device specified to comply with the PCI-

Express Compliance 1.0 Mode. The options are: Disabled and

Enabled.

7-11

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

PCI-E Express Jitter Tolerance

This feature allows the user to set the PCI-E Jitter Tolerance Level. The options are: 4 to 12.

PCI-E Port A Device 2/PCI-E Port B Device 4

If enabled, the feature allows you to set the device selected to be compliant with the PCI-Express Compliance 1.0 Mode. The options are:

Disabled, Enabled and Auto.

Clock Spectrum Feature

I f " E n a b l e d " , t h e B I O S w i l l s e n s o r a n d a t t e m p t t o r e d u c e t h e

Electromagnetic Interference caused by the components. The options are

Enabled and Disabled.

DRAM Data Integrity Mode

If enabled, this feature allows the data stored in the DRMA memory to be integrated for faster data processing. The options are 72-bit ECC,

144-bit ECC, Auto, Algorithms and Disabled.

ECC Error Type

This setting lets you select which type of interrupt to be activated as a result of an ECC error. The options are None, NMI (Non-Maskable

Interrupt), SMI (System Management Interrupt) and SCI (System Control

Interrupt.)

SERR Signal Condition

This setting specifies the conditions required to be qualified as an ECC error. The options are None, Single Bit, Multiple Bit and Both.

7-12

Chapter 7: BIOS

USB Device 29, Function 0 & 1 & 2 & 3

This setting allows you to Enable or Disable all functions for the USB devices specified.

Legacy USB Support

This setting allows you to enable support for Legacy USB devices. The settings are Enabled and Disabled.

Advanced Processor Options

Access the submenu to make changes to the following settings.

CPU Speed

This is a display that indicates the speed of the installed processor.

Hyper-threading

This setting allows you to Enable or Disable the function of hypert h r e a d i n g . E n a b l i n g h y p e r - t h r e a d i n g r e s u l t s i n i n c r e a s e d C P U performance. (Applicable for the XP systems.)

Thermal Manager 2 (*X6DA8-G2/X6DAE-G2 only)

If enabled, this feature allows you to select between Thermal Manager 1 and Thermal Manager 2. The options are Disable or Enable.

Set Maximum Extended CPUID=3

If enabled, this feature allows you to set the value of Maximum CPUID

Extended function to 3. The options are Disabled or Enabled.

7-13

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

I/O Device Configuration

Access the submenu to make changes to the following settings.

Serial Port A

This setting allows you to assign control of serial port A. The options are Enabled (user defined), Disabled, Auto (BIOS controlled) and OS

Controlled.

Base I/O Address

Select the base I/O address for serial port A. The options are 3F8,

2F8, 3E8 and 2E8.

Interrupt

Select the IRQ (interrupt request) for the parallel port. The options are IRQ3 and IRQ4.

Serial Port B

This setting allows you to assign control of serial port B. The options are Enabled (user defined), Disabled, Auto (BIOS controlled) and OS

Controlled.

Mode

Specify the type of device that will be connected to serial port B. The options are Normal, IR (for an infrared device) and ASK-IR.

Base I/O Address

Select the base I/O address for serial port B. The options are 3F8,

2F8, 3E8 and 2E8.

Interrupt

Select the IRQ (interrupt request) for the parallel port. The options are IRQ3 and IRQ4.

Parallel Port

This setting allows you to assign control of the parallel port. The options are Enabled (user defined), Disabled and Auto (BIOS controlled).

Base I/O Address

Select the base I/O address for the parallel port. The options are 378,

278 and 3BC.

7-14

Chapter 7: BIOS

Interrupt

Select the IRQ (interrupt request) for the parallel port. The options are IRQ5 and IRQ7.

Mode

Specify the parallel port mode. The options are Output, Bi-directional,

ECP and EPP.

DMA Channel

Specify the DMA channel. The options are DMA1 and DMA3.

Floppy Disk Controller

This setting allows you to assign control of the floppy disk controller.

The options are Enabled (user defined), Disabled, Auto (BIOS controlled) and OS Controlled.

Base I/O Address

Select the base I/O address for the Floppy port. The options are

Primary and Secondary.

7-15

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

DMI Event Logging

Access the submenu to make changes to the following settings.

Event Log Validity

This is a display, not a setting, informing you of the event log validity.

Event Log Capacity

This is a display, not a setting, informing you of the event log capacity.

View DMI Event Log

Highlight this item and press <Enter> to view the contents of the event log.

Event Logging

This setting allows you to Enable or Disable event logging.

ECC Event Logging

This setting allows you to Enable or Disable ECC event logging.

Mark DMI Events as Read

Highlight this item and press <Enter> to mark the DMI events as read.

Clear All DMI Event Logs

Select Yes and press <Enter> to clear all DMI event logs.

7-16

Chapter 7: BIOS

Console Redirection

Access the submenu to make changes to the following settings.

COM Port Address

Specifies to redirect the console to On-board COM A or On-board COM

B. This setting can also be Disabled.

BAUD Rate

Select the BAUD rate for console redirection. The options are 300, 1200,

2400, 9600, 19.2K, 38.4K, 57.6K and 115.2K.

Console Type

Choose from the available options to select the console type for console redirection. The options are VT100, VT100,8bit, PC-ANSI, 7bit, PC ANSI,

VT100+,

VT-UTF8.

Flow Control

Choose from the available options to select the flow control for console redirection. The options are: None, XON/XOFF, and CTS/RTS.

Console Connection

Select the console connection: either Direct or Via Modem.

Continue CR after POST

Choose whether to continue with console redirection after the POST routine. The options are On and Off.

7-17

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Hardware Monitor Logic

CPU Temperature Threshold

This option allows the user to set a CPU temperature threshold that will activate the alarm system when the CPU temperature reaches this pre-set temperature threshold. The options are 70 o C, 75

o

C, 80 o C and

85 o C.

Highlight this and hit <Enter> to see monitor data for the following items:

CPU1 Temperature: This item displays CPU1 Temperature.

CPU2 Temperature: This item displays CPU2 Temperature.

System Temperature: This item displays the system Temperature.

Auto Fan Control [4-wire, 3-wire]

Note: the fan control setting for the SuperWorkstation 7044A-82/7044A-8/

7044A-i2/7044A-i is defaulted to "4-wire". This is the recommended setting. The default setting for the motherboard is "disabled".

Fan1=

Fan2=

Fan3=

Fan4=

Fan5=

Fan6=

Fan7 (CPU Fan1)=

Fan 8 (CPU Fan2)=

Vcore A

Vcore B

P3V3

P5V

N12V

P12V

VDD

P5Vsb

P3P3Vsb

7-18

Chapter 7: BIOS

7-5 Security

Choose Security from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. Security setting options are displayed by highlighting the setting using the arrow keys and pressing <Enter>.

All Security BIOS settings are described in this section.

Supervisor Password Is:

This displays whether a supervisor password has been entered for the system. Clear means such a password has not been used and Set means a supervisor password has been entered for the system.

User Password Is:

This displays whether a user password has been entered for the system.

Clear means such a password has not been used and Set means a user password has been entered for the system.

7-19

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Set Supervisor Password

When the item "Set Supervisor Password" is highlighted, hit the <Enter> key.

When prompted, type the Supervisor's password in the dialogue box to set or to change supervisor's password, which allows access to the BIOS.

Set User Password

When the item "Set User Password" is highlighted, hit the <Enter> key.

When prompted, type the user's password in the dialogue box to set or to change the user's password, which allows access to the system at bootup.

Fixed Disk Boot Sector

This setting may offer some protection against viruses when set to Write

Protect, which protects the boot sector on the hard drive from having a virus written to it. The other option is Normal.

Password on Boot

This setting allows you to require a password to be entered when the system boots up. The options are Enabled (password required) and

Disabled (password not required).

7-20

Chapter 7: BIOS

7-6 Boot

Choose Boot from the Phoenix BIOS Setup Utility main menu with the arrow keys.

You should see the following display. Highlighting a setting with a + or - will expand or collapse that entry. See details on how to change the order and specs of boot devices in the Item Specific Help window. All Boot BIOS settings are described in this section.

+Removable Devices

Highlight and press <Enter> to expand the field. See details on how to change the order and specs of devices in the Item Specific Help window.

CD-ROM Drive

See details on how to change the order and specs of the CD-ROM drive in the Item Specific Help window.

+Hard Drive

Highlight and press <Enter> to expand the field. See details on how to change the order and specs of hard drives in the Item Specific Help w i n d o w .

7-21

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

7-7 Exit

Choose Exit from the Phoenix BIOS Setup Utility main menu with the arrow keys.

You should see the following display. All Exit BIOS settings are described in this section.

Exit Saving Changes

Highlight this item and hit <Enter> to save any changes you made and to exit the BIOS Setup utility.

Exit Discarding Changes

Highlight this item and hit <Enter> to exit the BIOS Setup utility without saving any changes you may have made.

Load Setup Defaults

Highlight this item and hit <Enter> to load the default settings for all items in the BIOS Setup. These are the safest settings to use.

7-22

Chapter 7: BIOS

Discard Changes

Highlight this item and hit <Enter> to discard (cancel) any changes you made. You will remain in the Setup utility.

Save Changes

Highlight this item and hit <Enter> to save any changes you made. You will remain in the Setup utility.

7-23

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Notes

7-24

Appendix A: BIOS POST Codes

Appendix A

BIOS POST Codes

This section lists the POST (Power On Self Test) codes for the PhoenixBIOS. POST codes are divided into two categories: recoverable and terminal.

Recoverable POST Errors

When a recoverable type of error occurs during POST, the BIOS will display an

POST code that describes the problem. BIOS may also issue one of the following beep codes:

1 long and two short beeps - video configuration error

1 continuous long beep - no memory detected

Terminal POST Errors

If a terminal type of error occurs, BIOS will shut down the system. Before doing so, BIOS will write the error to port 80h, attempt to initialize video and write the error in the top left corner of the screen.

The following is a list of codes that may be written to port 80h.

13h

14h

16h

17h

0Ah

0Bh

0Ch

0Eh

0Fh

10h

11h

12h

06h

07h

08h

09h

POST Code Description

02h Verify Real Mode

03h

04h

Disable Non-Maskable Interrupt (NMI)

Get CPU type

Initialize system hardware

Disable shadow and execute code from the ROM.

Initialize chipset with initial POST values

Set IN POST flag

Initialize CPU registers

Enable CPU cache

Initialize caches to initial POST values

Initialize I/O component

Initialize the local bus IDE

Initialize Power Management

Load alternate registers with initial POST values

Restore CPU control word during warm boot

Initialize PCI Bus Mastering devices

Initialize keyboard controller

1-2-2-3 BIOS ROM checksum

Initialize cache before memory Auto size

A-1

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

47h

48h

49h

4Ah

4Bh

4Ch

4Eh

4Fh

41h

42h

45h

46h

38h

3Ah

3Ch

3Dh

50h

51h

52h

54h

55h

58h

59h

5Ah

5Bh

29h

2Ah

2Ch

2Eh

2Fh

32h

33h

36h

20h

22h

24h

28h

POST Code Description

18h 8254 timer initialization

1Ah

1Ch

8237 DMA controller initialization

Reset Programmable Interrupt Controller

1-3-1-1 Test DRAM refresh

1-3-1-3 Test 8742 Keyboard Controller

Set ES segment register to 4 GB

Auto size DRAM

Initialize POST Memory Manager

Clear 512 kB base RAM

1-3-4-1 RAM failure on address line xxxx*

1-3-4-3 RAM failure on data bits xxxx* of low byte of memory bus

Enable cache before system BIOS shadow

Test CPU bus-clock frequency

Initialize Phoenix Dispatch Manager

Warm start shut down

Shadow system BIOS ROM

Auto size cache

Advanced configuration of chipset registers

Load alternate registers with CMOS values

Initialize extended memory for RomPilot

Initialize interrupt vectors

POST device initialization

2-1-2-3 Check ROM copyright notice

Initialize I20 support

Check video configuration against CMOS

Initialize PCI bus and devices

Initialize all video adapters in system

QuietBoot start (optional)

Shadow video BIOS ROM

Display BIOS copyright notice

Initialize MultiBoot

Display CPU type and speed

Initialize EISA board

Test keyboard

Set key click if enabled

Enable USB devices

2-2-3-1 Test for unexpected interrupts

Initialize POST display service

Display prompt “Press F2 to enter SETUP”

Disable CPU cache

A-2

Appendix A: BIOS POST Codes

85h

86h

87h

88h

89h

8Ah

8Bh

8Ch

81h

82h

83h

84h

7Ch

7Dh

7Eh

80h

93h

95h

96h

97h

98h

8Fh

90h

91h

92h

69h

6Ah

6Bh

6Ch

6Eh

70h

72h

76h

64h

66h

67h

68h

POST Code Description

5Ch Test RAM between 512 and 640 kB

60h

62h

Test extended memory

Test extended memory address lines

Jump to UserPatch1

Configure advanced cache registers

Initialize Multi Processor APIC

Enable external and CPU caches

Setup System Management Mode (SMM) area

Display external L2 cache size

Load custom defaults (optional)

Display shadow-area message

Display possible high address for UMB recovery

Display error messages

Check for configuration errors

Check for keyboard errors

Set up hardware interrupt vectors

Initialize Intelligent System Monitoring

Initialize coprocessor if present

Disable onboard Super I/O ports and IRQs

Late POST device initialization

Detect and install external RS232 ports

Configure non-MCD IDE controllers

Detect and install external parallel ports

Initialize PC-compatible PnP ISA devices

Re-initialize onboard I/O ports.

Configure Motherboard Configurable Devices (optional)

Initialize BIOS Data Area

Enable Non-Maskable Interrupts (NMIs)

Initialize Extended BIOS Data Area

Test and initialize PS/2 mouse

Initialize floppy controller

Determine number of ATA drives (optional)

Initialize hard-disk controllers

Initialize local-bus hard-disk controllers

Jump to UserPatch2

Build MPTABLE for multi-processor boards

Install CD ROM for boot

Clear huge ES segment register

Fix up Multi Processor table

1-2 Search for option ROMs. One long, two short beeps on checksum failure

A-3

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

BCh

BDh

BEh

BFh

C0h

C1h

C2h

C3h

B2h

B4h

B5h

B6h

B7h

B9h

BAh

BBh

C4h

C5h

C6h

C7h

C8h

C9h

CAh

CBh

A2h

A4h

A8h

AAh

ACh

AEh

B0h

B1h

POST Code Description

99h Check for SMART Drive (optional)

9Ah

9Ch

Shadow option ROMs

Set up Power Management

9Dh

9Eh

9Fh

A0h

Initialize security engine (optional)

Enable hardware interrupts

Determine number of ATA and SCSI drives

Set time of day

Check key lock

Initialize typematic rate

Erase F2 prompt

Scan for F2 key stroke

Enter SETUP

Clear Boot flag

Check for errors

Inform RomPilot about the end of POST.

CCh

POST done - prepare to boot operating system

1 One short beep before boot

Terminate QuietBoot (optional)

Check password (optional)

Initialize ACPI BIOS

Prepare Boot

Initialize SMBIOS

Initialize PnP Option ROMs

Clear parity checkers

Display MultiBoot menu

Clear screen (optional)

Check virus and backup reminders

Try to boot with INT 19

Initialize POST Error Manager (PEM)

Initialize error logging

Initialize error display function

Initialize system error handler

PnPnd dual CMOS (optional)

Initialize note dock (optional)

Initialize note dock late

Force check (optional)

Extended checksum (optional)

Redirect Int 15h to enable remote keyboard

Redirect Int 13h to Memory Technologies

Devices such as ROM, RAM, PCMCIA, and serial disk

Redirect Int 10h to enable remote serial video

A-4

Appendix A: BIOS POST Codes

POST Code Description

CDh Re-map I/O and memory for PCMCIA

CEh

D2h

Initialize digitizer and display message

Unknown interrupt

The following are for boot block in Flash ROM

EFh

F0h

F1h

F2h

F3h

F4h

F5h

F6h

F7h

E7h

E8h

E9h

EAh

EBh

ECh

EDh

EEh

POST Code Description

E0h Initialize the chipset

E1h

E2h

Initialize the bridge

Initialize the CPU

E3h

E4h

E5h

E6h

Initialize system timer

Initialize system I/O

Check force recovery boot

Checksum BIOS ROM

Go to BIOS

Set Huge Segment

Initialize Multi Processor

Initialize OEM special code

Initialize PIC and DMA

Initialize Memory type

Initialize Memory size

Shadow Boot Block

System memory test

Initialize interrupt vectors

Initialize Run Time Clock

Initialize video

Initialize System Management Manager

Output one beep

Clear Huge Segment

Boot to Mini DOS

Boot to Full DOS

* If the BIOS detects error 2C, 2E, or 30 (base 512K RAM error), it displays an additional word-bitmap (xxxx) indicating the address line or bits that failed. For example, “2C

0002” means address line 1 (bit one set) has failed. “2E 1020" means data bits 12 and 5 (bits 12 and 5 set) have failed in the lower 16 bits. The BIOS also sends the bitmap to the port-80 LED display. It first displays the checkpoint code, followed by a delay, the high-order byte, another delay, and then the loworder byte of the error.

It repeats this sequence continuously.

A-5

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Notes

A-6

Appendix B: Software Installation

Appendix B

Software Installation

After all the hardware has been installed, you must first configure the Adaptec

Embedded Serial ATA RAID Driver before you install the Windows operating system. The necessary drivers are all included on the Supermicro bootable CDs that came packaged with your motherboard.

B-1 Adaptec Embedded SATA RAID Controller Driver

Serial ATA (SATA)

Serial ATA (SATA) is a physical storage interface. It uses a single cable with a minimum of four wires to create a point-to-point connection between devices. It is a serial link which supports SATA transfer rates from 150MBps. Because the serial cables used in SATA are thinner than the traditional cables used in Parallel

ATA (PATA), SATA systems have better airflow and can be installed in smaller chassis than PATA. In addition, the cables used in PATA can only extend to

40cm long, while SATA cables can extend up to one meter. Overall, SATA provides better functionality than PATA.

Intel ICH5R Controller Hub

Located in the South Bridge of the Intel E7525 (Tumwater) Chipset, the ICH5R I/O

Controller Hub provides the I/O subsystem with access to the rest of the system.

It supports 2-channel Ultra ATA/100 Bus Master IDE controller (PATA) and two channel SATA Host Controllers, which support up to two Serial ATA ports and up to two RAID drives.

B-1

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Configuring BIOS for SATA RAID Functions

1. Press the <Del> key during system bootup to enter the BIOS Setup Utility.

Note: If it is the first time to power on the system, we recommend that you load the Optimized Default Settings. If you have already done so, please skip to Step

3.

2. Use the arrow keys to select the "Exit" Menu. Once in the "Exit" Menu, scroll down the menu to select the item- "Load Optimized Default settings" and press the <Enter> key. Select "OK" to confirm the selection. Press the <Enter> key to load the default settings to the BIOS.

3. Use the arrow keys to select the "Main" Menu in the BIOS.

4. Scroll down to the next item-"SATA RAID Enable", select "Enabled" and press

<Enter>.

5. Tap the <Esc> key and scroll down to "Exit". Select "Save and Exit" from the "Exit" menu. Press the <Enter> key to save the changes and exit the BIOS.

6. Once you've exited the BIOS Utility, the system will re-boot.

7. During the system startup, press the <Ctrl> and the <A> keys simultaneously to run the Adaptec RAID Configuration Utility when prompted by the following message:

Press <Ctrl><A> for Adaptec RAID Configuration Utility

B-2

Appendix B: Software Installation

Adaptec Embedded SATA with HostRAID Controller Driver

Adaptec's Embedded Serial ATA RAID with HostRAID controller adds RAID functionality to the Serial ATA I/O controller by supporting RAID 0 (Striping) or RAID

1 (Mirroring) to enhance the industry's pioneer PCI-to-e host controller products.

RAID striping (RAID 0) can greatly improve hard disk I/O performance because of its capability in striping data across multiple drives. RAID mirroring (RAID 1) allows the data to be simultaneously written to two drives, so critical data is always available even if a single hard disk fails. Due to the built-in functionality, the X6DA8-G2 is specially designed to keep pace with the increasing performance demands of computer systems by improving disk I/O throughput and providing data accessibility regardless of a single disk failure. By incorporating the Adaptec Embedded Serial ATA into the motherboard design, Supermicro's

X6DA8-G2 offers the user with the benefits of SATARAID without the high costs associated with hardware RAID applications.

Note: For Adaptec's RAID Driver Installation Instructions, please refer to the

Adaptec RAID Controller User's Guide: "Emb_SA_RAID_UG.pdf" in the CD that came with this motherboard. You can also download a copy of Adaptec's User's

Guide from our web site at www.supermicro.com.

The Adaptec RAID Configuration Utility is an embedded BIOS Utility, including:

*Array Configuration Utility: Use this utility when you want to create, configure and manage arrays.

* Disk Utilities: Use this option to format or verify disks.

To run the Adaptec RAID Configuration Utility, you will need to enable the

RAID function in the system BIOS (refer to Chapter 4 for System BIOS

Configurations), and then, press the <Ctrl> and <A> keys simultaneously when prompted to do so during the system startup. (Refer to the previous page for detailed instructions.)

Note: To select an option, use the arrow keys to highlight the item and then press the <Enter> key to select it. To return to the previous menu, press the

<ESC> key.

Using the Adaptec RAID Configuration Utility (ARC)

The Array Configuration Utility (ACU) enables you to create, manage, and delete arrays from the controller’s BIOS, add and delete spare drives, and initialize drives. During the system startup, press <Ctrl> and <A> key simultaneously, and the main menu will appear.

B-3

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Managing Arrays

Select this option to view array properties, and delete arrays. The following sections describe the operations Of "Managing Arrays".

To select this option, use the arrow keys and the <enter> key to select

"Managing Arrays" from the main menu (as shown above).

B-4

Appendix B: Software Installation

Viewing Array Properties

To view the properties of an existing array:

1. At the BIOS prompt, press Ctrl+A.

2. From the ARC menu, select Array Configuration Utility (ACU).

3. From the ACU menu, select Manage Arrays (as shown on the previous screen.)

4. From the List of Arrays dialog box, select the array you want to view and press Enter.

The Array Properties dialog box appears, showing detailed information on the array. The physical disks associated with the array are displayed here.

5. Press Esc to return to the previous menu.

Deleting Arrays

*Warning: Back up the data on an array before you delete it to prevent the loss of data. Deleted arrays cannot be restored.

To delete an existing array:

1. Turn on your computer and press Ctrl+A when prompted to access the ARC utility.

2. From the ARC main menu, select Array Configuration Utility

(ACU).

3. From the ACU menu, select Manage Arrays.

4. Select the array you wish to delete and press Delete.

5. In the Array Properties dialog box, select Delete and press

Enter. The following prompt is displayed:

*Warning!! Deleting the array will render array unusable. Do you want to delete the array?(Yes/No):

RAID 1 only—the following prompt is also displayed:

Deleting the partition will result in data loss! Do you also want to delete the partition? (Yes/No):

6. Press Yes to delete the array or partition or No to return to the previous menu.

7. Press Esc to return to the previous menu.

B-5

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Creating Arrays

Before creating arrays, make sure the disks for the array are connected and installed in your system. Note that disks with no usable space, or disks that are un-initialized are shown in gray and cannot be used. See

Initializing Disk Drives

.

To create an array:

1 Turn on your computer and press Ctrl+A when prompted to access the ARC utility.

2 From the ARC menu, select Array Configuration Utility Main Menu

(ACU) (as shown on the first screen on page B-5).

3 From the ACU menu, select Create Array.

4 Select the disks for the new array and press Insert (as the screen shown below).

(*Note: To deselect any disk, highlight the disk and press Delete.)

5 Press Enter when both disks for the new array are selected. The

Array Properties menu displays (as the screen shown on the next page).

B-6

Appendix B: Software Installation

Assigning Array Properties

Once you've create a new array, you are ready to assign the properties to the array.

*Caution: Once the array is created and its properties are assigned, you cannot change the array properties using the ACU. You will need to use the Adaptec Storage Manager - Browser Edition. (Refer to Adaptec's

User's Guide in the enclosed CD.)

To assign properties to the new array:

1. In the Array Properties menu (as shown in the following screen), select an array type and press Enter.

Note that only the available array types: RAID 0, and RAID1, are displayed on the screen. (*RAID 0 or RAID 1 requires two drives.)

B-7

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

2. Under the item "Arrays Label", type in an label and press Enter.

(*Note: The label shall not be more than 15 characters.)

3. For RAID 0, select the desired stripe size. (*Note: Available stripe sizes are 16, 32, and 64 KB-default. It is recommended that you do not change the default setting.)

4. The item: "Create RAID via" allows you to select between the different creating methods for RAID 0 and RAID 1.

The following table gives examples of when each is appropriate.

Raid Level Create Via When Appropriate

RAID 0

RAID 0

No Init

Migrate

(*Note)

Creating a RAID 0 on new drives

Creating a RAID 0 from one new drive and one drive with data you wish to preserve

RAID 1

RAID 1

RAID 1

RAID 1

Build1

Clear

Quick

Init

Any time you wish to create a RAID 1, but especially if you have data on one drive that you wish to preserve

Creating a RAID 1 on new drives, or when you want to ensure that the array contains no data after creation.

Fastest way to create a RAID 1.

Appropriate when using new drives

(*Note:

If you select Migrate for RAID 0, or Build for RAID 1, you will be asked to select the source drive. The contents of the source drive will be preserved. However, the data on the new drive will be lost.)

B-8

Appendix B: Software Installation

5. When you are finished, press Done (as the screen shown below).

Notes:

1. Before adding a new drive to an array, back up any data contained on the new drive. Otherwise, all data will be lost.

2. If you stop the Build or Clear process on a RAID 1 from ACU, you can restart it by pressing Ctrl+R.

3. A RAID 1 created using the Quick Init option may return some data miscompares if you later run a consistency check. This is normal and is not a cause for concern.

4. The ACU allows you to use drives of different sizes in a

RAID . However, during a build operation, only the smaller drive can be selected as the source or first drive.

5. When migrating from single volume to RAID 0, migrating from a larger drive to a smaller drive is allowed. However, the destination drive must be at least half the capacity of the source drive.

6. Adaptec does not recommend that you migrate or build an array on

Windows dynamic disks (volumes), as it will result in data loss.

Warning: Do not interrupt the creation of a RAID 0 using the Migrate option. If you do, you will not be able to restart, or to recover the data that was on the source drive.

B-9

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Adding a Bootable Array

To make an array bootable:

1. From the Main menu, select Manage Arrays.

2. From the List of Arrays, select the array you want to make bootable, and press Ctrl+B.

3. Enter Y to create a bootable array when the following message is displayed: "This will make all other existing bootable array non-bootable. Do you want to make this array bootable? (Yes/No):" Then, a bootable array will be created. An asterisk will appear next to the bootable array (as shown in the picture below:)

Deleting a Bootable Array

To delete a bootable array:

1. From the Main menu, select Manage Arrays.

2. From the List of Arrays, select the bootable array (*) you want to delete, and press Ctrl+B. (* a bootable array is the array marked with an asterisk

(as shown in the picture above.)

3. Enter Y to delete a bootable array when the following message is displayed: "The array is already marked bootable. Do you want to make this array as not bootable? (Yes/No):" Then, the bootable array will be deleted and the asterisk will disappear.

(*Note: do not use the delete key to delete the bootable array.)

B-10

Appendix B: Software Installation

Adding/Deleting Hotspares

(*Note: In order to rebuild a RAID (RAID 0 or RAID 1), you would need to add a new HDD as a hotspare.)

1. Turn on your computer and press Ctrl+A as prompted to access the ARC

Utility.

2. From the ARC menu, select Array Configuration Utility (ACU).

3. From the ACU menu, select Add/Delete Hotspares.

4. Use the up and down arrow keys to highlight and select the disk you want to designate as a hotspare, and press <Insert>, and then, press

<Enter>.

5. Press yes when the following prompt is displayed:

"Do you want to create spare?" (Yes/No?)

The spare you have selected will appear in the Select Drive Menu.

B-11

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Initializing Disk Drives

If an installed disk does not appear in the disk selection list for creating a new array, or if it appears grayed out, you may have to initialize it before you can use it as part of an array. Drives attached to the controller must be initialized before they can be used in an array.

Caution: Initializing a disk overwrites the partition table on the disk and makes any data on the disk inaccessible. If the drive is used in an array, you may not be able to use the array again.

Do not initialize a disk that is part of a boot array. To determine which disks are associated with a particular array, please refer to

Viewing Array Properties.

To initialize drives:

1. Turn on your computer and press Ctrl+A when prompted to access the ARC utility.

2. From the ARC menu, select Array Configuration Utility (ACU) (as shown in the screen below).

3. Select Initialize Drives (as shown in the screen below).

B-12

Appendix B: Software Installation

4. Use the up and down arrow keys to highlight the disk you wish to initialize and press Insert (as shown in the screen below).

B-13

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

5. Repeat Step 4 so that both drives to be initialized are selected (as shown in the screen below).

6. Press Enter.

7. Read the warning message as shown in the screen.

8. Make sure that you have selected the correct disk drives to initialize.

If correct, type Y to continue.

B-14

Appendix B: Software Installation

Rebuilding Arrays

*Note 1: Rebuilding applies to Fault Tolerant array (RAID 1) only.

If an array Build process (or initialization) is interrupted or critical with one member missing, you must perform a Rebuild to optimized its functionality. For a critical array Rebuild operation, the optimal drive is the source drive.

*Note 2: If no spare array exists and a hard disk drive fails, you need to create a spare before you can rebuild an array.

To Rebuild an array:

1 From the Main Menu, select Manage Arrays (as shown in the screen below). From the List of Arrays, select the array you want to Rebuild.

2 Press Ctrl+R to Rebuild.

B-15

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Using the Disk Utilities

The Disk Utilities enable you to format or verify the media of your Serial

ATA hard disks.

To access the disk utilities:

1. Turn on your computer and press Ctrl+A when prompted to access the ARC utility (as shown in the screen below.)

B-16

Appendix B: Software Installation

2. From the ARC menu, select Disk Utilities as shown in the screen below.

3 Select the desired disk and press Enter (as shown in the screen below.)

B-17

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

You can choose from the following options:

1. Format Disk—Simulates a low-level format of the hard drive by writing zeros to the entire disk. Serial ATA drives are low-level formatted at the factory and do not need to be low-level formatted again.

(*Caution: Formatting destroys all data on the drive. Be sure to back up your data before performing this operation.)

2. Verify Disk Media—Scans the media of a disk drive for defects.

To Exit Adaptec RAID Configuration Utility

1. Once you have completed RAID array configurations, press ESC to exit. The following screen will appear.

2. Press Yes to exit the Utility.

(*For more information regarding Adaptec RAID Utility, please refer to Adaptec's User's Guide in the CD included in your shipping package. You can also download a copy of Adaptec

User's Guide from our web site at: www. supermicro.com.)

B-18

Appendix B: Software Installation

B-2 Installing Intel's ICH5R Driver w/ Adaptec and

Windows OS

a. Insert Supermicro's bootable CD that came with the package into the

CD Drive during the system reboot, and the screen:"Super Micro Driver

Diskette Maker" will appear.

b. Choose from the list the item: "Intel ICH5R Driver by 3rd Party

(Adaptec)" and press <ENTER>.

c. From the next screen displayed, choose the OS driver you want to install and press <Enter>.

d. Insert a formatted diskette into drive A: and press <Enter> as prompted.

e. Exit the program after the process is completed. Then, reboot the system.

f. Insert Microsoft Windows OS Setup CD in the CD Driver, and the system will start to boot up from CD.

g. Press the <F6> key when the message-"Press F6 if you need to install a third party SCSI or RAID driver" displays.

h. When the Windows OS Setup screen appears, press "S" to specify additional device(s).

i. Insert the driver diskette-"Adaptec Embedded Serial ATA Raid Controller

Driver" into Drive A: and press the <Enter> key.

j. Choose Adaptec Embedded Host Serial ATA Raid Controller from the list indicated in the Windows OS Setup Screen, and press the <Enter> key.

k. Press the <Enter> key to continue the installation process. (If you need to specify any additional devices to be installed, do it at this time.) Once all devices are specified, press the <Enter> key to continue with the installation.

l. From the Windows OS Setup screen, press the <Enter> key. The OS

Setup will automatically load all device files, and, then, continue the

Windows OS installation.

m. After Windows OS Installation is completed, the system will automatically reboot.

B-19

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

B-3 Installing Other Software Programs and Drivers

A. Installing Drivers other than Adaptec Embedded Serial

ATA RAID Controller Driver

After you've installed Windows Operating System, a screen as shown below will appear. You are ready to install software programs and drivers that have not yet been installed. To install these software programs and drivers, click the icons to the right of these items.

Driver/Tool Installation Display Screen

(*Note: Click the icons showing a hand writing on paper to view the readme files for each item. Click the computer icons to the right of these items to install each item (from top to the bottom) one at a time. After installing

each item, you must re-boot the system before moving on to the

next item on the list. You should install everything here except for the

SUPER Doctor utility, Intel LDCM and the LAN/SCSI driver diskettes, which are optional. The bottom icon with a CD on it allows you to view the entire contents of the CD. )

(*Please refer to the Adaptec User's Guide for the installation of

Adaptec's Serial ATA RAID Controller Driver. Adaptec's User's

Guide is included in the CD. You can also download a copy of the user's guide from our web site.)

B-20

Appendix B: Software Installation

Supero Doctor III

The Supero Doctor III program is a Web base management tool that supports remote management capability. It includes Remote and Local

Management tools. The local management is called SD III Client. The

Supero Doctor III program included on the CDROM that came with your motherboard allows you to monitor the environment and operations of your system. Supero Doctor III displays crucial system information such as CPU temperature, system voltages and fan status. See the Figure below for a display of the Supero Doctor III interface.

Supero Doctor III Interface Display Screen-I (Health Information)

B-21

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Supero Doctor III Interface Display Screen-II (Remote Control)

(*Note: SD III Software Revision 1.0 can be downloaded from our Web site at: ftp://ftp.supermicro.com/utility/Supero_Doctor_III/. You can also download SDIII User's Guide at: http://www.supermicro.com/PRODUCT/

Manuals/SDIII/UserGuide.pdf. For Linux, we will still recommend Supero

Doctor II.)

B-22

Appendix C: System Specifications

Appendix C

System Specifications

Processors

Single or dual 604-pin Intel

®

Xeon TM processors at a front side (system) bus speed of 800 MHz. (Please refer to the support section of our web site for a complete listing of supported processors:

(http://www.supermicro.com).

Chipset

Intel E7525 chipset

BIOS

8 MB Phoenix

®

Flash ROM

Memory Capacity

X6DA8-G2/X6DAE-G2: Eight 240-pin DIMM sockets supporting up to 16

GB of registered ECC DDR2-400 (PC3200) SDRAM

X6DA8-G/X6DAE-G: Eight 184-pin DIMM sockets supporting up to 16 GB of registered ECC DDR333 or 32 GB of registered ECC DDR266 SDRAM

Note: Interleaved memory - requires memory to be installed two at a time. See the memory section in Chapter 5 for details.

SCSI Controller (7044A-82/7044A-8 only)

Adaptec AIC-7902 for dual channel Ultra320 onboard SCSI

SCSI Backplane Controller (7044A-82/7044A-8 only)

CSE-SCA-743S1: SAF-TE compliant backplane supports eight (8) SCA hot-swap SCSI drives

Peripheral Drives/Bays

One (1) 3.5" floppy drive

Two (2) 5.25" drive bays

Eight (8) SCSI drive bays (7044A-82/7044A-8 only)

Expansion Slots

Chassis: Seven (7) I/O chassis slots

Motherboard: total of six (6) PCI-Express/PCI-X slots

C-1

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Serverboard

Model: X6DA8-G2 (7044A-82), X6DA8-G (7044A-8), X6DAE-G2 (7044A-i2),

X6DAE-G (7044A-i)

Form Factor: Extended ATX

Dimensions: 12 x 13.05 in (304.8 x 331.5 mm)

Chassis

Model: SC743S1-645 (7044A-82 and 7044A-8), SC743i-645 (7044A-i2 and

7044A-i)

Form Factor: 4U rackmount/tower

Dimensions: (WxHxD as 4U) 6.94" x 17.125 x 24.125 in. (17.6 x 435 x

612.8 mm)

Weight

Gross (Bare Bone): 63 lbs. (28.6 kg.)

System Cooling

Four (4) hot-swap 8-cm chassis PWM cooling fans

System Input Requirements

AC Input Voltage: 100-240 VAC

Rated Input Current: 11A @ 90V

Rated Input Frequency: 50 to 60 Hz

Power Supply

Rated Output Power: 645W (Model# SP645-PS, Part# PWS-0060)

Rated Output Voltages: +12Vtotal (46A), +5V (30A), +3.3V (30A), +5Vsb

(4.0A)

Operating Environment

Operating Temperature: 10º to 35º C (50º to 95º F)

Non-operating Temperature: -40º to 70º C (-40º to 158º F)

Operating Relative Humidity: 8% to 90% (non-condensing)

Non-operating Relative Humidity: 5 to 95% (non-condensing)

Regulatory Compliance

Electromagnetic Emissions:

FCC Class B, EN 55022 Class B, EN 61000-3-2/-3-3, CISPR 22 Class B

C-2

Appendix C: System Specifications

Electromagnetic Immunity:

EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,

EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)

Safety:

EN 60950/IEC 60950-Compliant

UL Listed (USA)

CUL Listed (Canada)

TUV Certified (Germany)

CE Marking (Europe)

C-3

S

UPER

W

ORKSTATION 7044A-82/7044A-8/7044A-i2/7044A-i Manual

Notes

C-4

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement

Table of contents