7-2. Setting of address switch Indoor unit do not run without address

7-2. Setting of address switch
Make sure that power source is turning off.
Indoor unit control board
SW2
SW4
SW3
< At delivery (All models)> SW1
ON
OFF
ON
OFF
1 2 3 4 5 6 7 8 9 10
SW5
SW14
< At delivery (P72·96)>
12
9 10
6
10 8 CN82 1
ON
SW12
SW11
901
901
CN62 1
1
2
3
F012
1 2 3 45
< At delivery (P15~54)>
SW7
3
JP2
W254665G06
A B C D E F
1
O
F
F
8
78
7
78
6
BCDE
5
789A
240V 220V
4
456
3
23
SWC
2
23
SWA
1
3456
3
2
1
1
JP1
456
0 1 2 3 4 5 6 7 8 9
ON
G 1 2 3 SW1 ON
FP-AD-R
1 2 3 45
SW 4
ASSY
ON
OFF
SW 4
1)In case using M-NET remote controller, address is set by rotary switches.(SW11,SW12)
* It is not necessary setting address in case of using unit remote controller.
Indoor unit do not run without address setting in field.
2) Indoor unit address setting rule is different by each field work.
Refer to install manual of outdoor unit , operate the address setting.
3)Setting the address is combination of SW11(1st digit address setting) and SW12(2nd digit address setting).
Address " 3 " setting is composed SW11 " 3 " and SW12 " 0 " .
Address " 25 " setting is composed SW11 " 5 " and SW12 " 2 " .
14
7-3. Setting of Dip-switch (at delivery)
Models
Dip-SW
PEFY-P15
NMHU-E
ON
OFF
PEFY-P18
NMHU-E
ON
OFF
PEFY-P24
NMHU-E
ON
OFF
PEFY-P27
NMHU-E
ON
OFF
PEFY-P30
NMHU-E
ON
OFF
PEFY-P36
NMHU-E
ON
OFF
PEFY-P48
NMHU-E
ON
OFF
PEFY-P54
NMHU-E
ON
OFF
PEFY-P72
NMHU-E
ON
OFF
PEFY-P96
NMHU-E
ON
OFF
SW1
1 2 3 4 5 6 7 8 910
SW1
1 2 3 4 5 6 7 8 910
SW1
1 2 3 4 5 6 7 8 910
SW1
1 2 3 4 5 6 7 8 910
SW1
1 2 3 4 5 6 7 8 910
SW1
1 2 3 4 5 6 7 8 910
SW1
1 2 3 4 5 6 7 8 910
SW1
1 2 3 4 5 6 7 8 910
SW1
1 2 3 4 5 6 7 8 910
SW1
1 2 3 4 5 6 7 8 910
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
SW2
123456
SW2
123456
SW2
123456
SW2
123456
SW2
123456
SW2
123456
SW2
123456
SW2
123456
SW2
123456
SW2
123456
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
SW3
1 2 3 4 5 6 7 8 910
SW3
1 2 3 4 5 6 7 8 910
SW3
1 2 3 4 5 6 7 8 910
SW3
1 2 3 4 5 6 7 8 910
SW3
1 2 3 4 5 6 7 8 910
SW3
1 2 3 4 5 6 7 8 910
SW3
1 2 3 4 5 6 7 8 910
SW3
1 2 3 4 5 6 7 8 910
SW3
1 2 3 4 5 6 7 8 910
SW3
1 2 3 4 5 6 7 8 910
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
SW4
1 2 345
SW4
1 2 345
SW4
1 2 345
SW4
1 2 345
SW4
1 2 345
SW4
1 2 345
SW4
1 2 345
SW4
1 2 345
SW4
1 2 345
SW4
1 2 345
ON
OFF
SW5
220V
240V
ON
OFF
ON
OFF
SW5
220V
240V
ON
OFF
ON
OFF
SW5
220V
240V
ON
OFF
ON
OFF
SW5
220V
240V
ON
OFF
ON
OFF
SW5
220V
240V
ON
OFF
ON
OFF
SW5
220V
240V
ON
OFF
ON
OFF
SW5
220V
240V
ON
OFF
ON
OFF
SW5
220V
240V
ON
OFF
ON
OFF
SW5
220V
240V
ON
OFF
ON
OFF
SW5
220V
240V
ON
OFF
SW7
123
SW7
123
SW7
123
SW7
123
SW7
123
SW7
SWC
SWA Standard
1
Indicate
123
SW7
123
SW7
123
SW7
123
SW7
123
7-4. Attention for test run
Equipment which is attached drain water lift up kit can be tested
pump out test when power supplied.(connect the connector(A))
< Drain-up machine >
Test run Connector (red)(A)
After pump out test, remove the connector
and put in the dummy connector.
After test run,remove the connector (A)(Fig .1)
7-5. Function the LED of the indoor unit service board
Symbol
LED1
LED2
15
LED operation under normal state
At applying main power source
At receiving MA transmission power source
Lighting
Lighting