HOME GENERATOR SYSTEMS
STANDBY
SOLUTI
NS
8-10kW Air-Cooled
Home Comfort | Home Generator Systems
SEREGEN® SERIES home Generator systems
8-10kW Air-cooled Generators
Rheem automatic standby generators provide
permanent, backup protection from power outages
for your home and family. Find the right generator
with flexible power solution options that allow you to
select the level of backup power protection needed
for your household.
Fully Automatic – Advanced electronics will detect a utility
power outage and automatically start the generator whether you
are home or away.
Flexible Placement* – Tested against the tough NFPA 37
standard, Rheem 8-10kW† standby generators can be placed as
close as 18" from the home providing more placement options in
your yard — perfect for tight lot lines.
Reliable Engine Power – Powered by a premium Briggs &
Stratton engine, our 8-10kW standby generators feature a newly
designed engine for standby applications for improved reliability,
performance and durability. They are powered by Briggs &
Stratton engines that are design-engineered to dependably take
on the most demanding jobs.
Durable Enclosure – Rust-resistant, Galvanneal steel
enclosures are made from the same materials used in the
automotive industry.
Quick Response – Automatically powers your home in
seconds after sensing a power outage.
3-Year Limited Parts Warranty ‡ – We stand behind our
warranty and make it easy for our customers to work with us.
Note: Refer to the installation manual for product specifications and installation check list.
*Installation must strictly comply with all applicable codes, industry standards, laws and
regulations. Running engines give off carbon monoxide, an odorless, colorless, poison gas
so it is important to keep exhaust gas away from any windows, doors, ventilation intakes or
crawl spaces. Carbon monoxide detectors must be installed and maintained in your home.
‡Refer to owner’s manual for warranty information.
AVAILABLE ACCESSORIES
MAINTENANCE KITs - PN 6261/6035
Rheem maintenance kits help you complete scheduled maintenance
and prevent costly repairs on your standby generator. Maintenance kits
are designed specifically for your generator’s needs. Each kit contains
air and oil filters, synthetic oil, and spark plug(s) for your model.
cold weather KITs - PN 6262/6030A
AHelp ensure smooth starting and reliable operation in the winter
months. The thermostatically controlled battery warmer and oil
heater(s) activate as the temperature drops.
BASIC WIRELESS MONITOR - PN 6264
Easy, trouble-free monitoring is a reality with the new Rheem Basic
Wireless Monitor. Place the wireless monitor in your home and know
your generator is working without ever having to go outside.
part number
GEN8AD-V
GEN10AD-V
Model Series
SEREGEN 50
SEREGEN 100
Nominal Output Capacity †
(LP/NG)
8/6kW
10/9kW
Surge Output Capacity
(LP/NG)
10/7.5kW
12.5/11.25kW
Briggs & Stratton Model
Equivalent
040351
040375
Fuel Type
Propane (LP Vapor)
Natural Gas (NG)
Propane (LP Vapor)
Natural Gas (NG)
Voltage
120/240V AC, Single Phase, 1.0 pf
120/240V AC, Single Phase, 1.0 pf
Frequency
60Hz
60Hz
Nominal Output Current
(LP/NG)
33/25A
42/38A
Fuel Consumption ‡ (½ Load)
1.04 gal/hr (LP Vapor)
94 ft3/hr (NG)
1.18 gal/hr (LP Vapor)
111 ft3/hr (NG)
Fuel Consumption ‡ (Full Load)
1.57 gal/hr (LP Vapor)
121 ft3/hr (NG)
1.82 gal/hr (LP Vapor)
169 ft3/hr (NG)
Alternator
Brushed, Computer Friendly
Brushed, Computer Friendly
Voltage Regulation
Fully Automatic
Fully Automatic
Engine
Briggs & Stratton Single-Cylinder
Briggs & Stratton Vanguard V-Twin
Engine Cooling
Air-Cooled
Air-Cooled
Full Pressure Lubrication
Yes
Yes
Overcrank Protection
Yes
Yes
Dimensions (L x W x H)
28" x 24.4" x 35.1"
28” x 24.4” x 35.1”
Weight (generator only)
252 lbs.
272 lbs.
Transfer Switch Part Options
TS509C
TS100AD, TS100A16, TS150AD,
TS200A, TS200AD
Transfer Switch Options
50A/10 Circuit
100A/16 Circuit, 100A, 150A, 200A
Maintenance Kit
6261
6035
Cold Weather Kit
6262
6030A
Limited Warranty*
3 Year
3 Year
Turn-Key Extras Included
Battery Charger, Hour Meter,
Installation Base
Battery Charger, Hour Meter,
Installation Base
† These generators are rated in accordance with UL 2200 and CSA Standard C22.2 No. 100-04
‡ Fuel consumption rates are estimated based on normal operating conditions. Generator operation may be
greatly affected by elevation and the cycling operation of multiple electrical appliances – fuel flow rates may
vary depending on these factors.
Tested against the tough NFPA 37 Standard.
AUTOMATIC TRANSFER SWITCH (Sold separately)
Part Number
TS509C
TS100AD
TS100A16
TS150AD
TS200A
TS200AD
Series Compatibility
SEREGEN
50
SEREGEN
100/300
SEREGEN
100/300
SEREGEN
100/300
SEREGEN
100/300
SEREGEN
100/300
Current Capacity
50A
100A
100A
150A
200A
200A
Service Entrance Disconnect*
—
Yes
—
Yes
—
—
Panelboard
10 Position
Not Included
16 Position
Not Included
Not Included
Not Included
ACCM
—
Included
Included
Included
Included
Included
Dimensions (L x W x H)
14-1/4 x 6 x 21
14 x 6 x 24
14 x 6 x 24
16 x 7 x 30
16 x 7 x 22
16 x 7 x 30
Weight
30 lbs.
43 lbs.
37 lbs.
58 lbs.
48 lbs.
59 lbs.
Limited Warranty
3 Year
3 Year
v 3 Year
3 Year
3 Year
3 Year
*Review local codes to determine if a transfer switch with separate service entrance disconnect is required.
These transfer switches are rated in accordance with UL 1008 and CSA Standard C22.2 No. 178-1978.
In keeping with its policy of continuous progress and improvement, Rheem reserves the right to make changes without notice.
Rheem Replacement Parts • 4744 Island Ford Road
Randleman, NC 27317 • 336.495.6800 • 336.495.6867 fax • 877.369.9400 technical support
www.rheemparts.com
Rheem.com
PRINTED IN USA 06/13 PRO-8221
Open as PDF