SPRAY GUN AZ3 HTE2, AZ3 HTE2 AV, AZ3 HTE2 HVLP

Instruction Manual
Contacts:
ANEST IWATA Europe S.r.l.
46, Corso Vigevano 10155, Torino • ITALY
Direct Tel. +39 011 - 22 74 402
Fax +39 011 - 22 74 406
info@anest-iwataeu.com
www.anest-iwataeu.com
ANEST IWATA USA, Inc.
9920 Windisch Road,
West Chester, OH 45069
Tel: +1 513.755.3100
Toll Free: 800.440.0282
inquiry@anestiwata.com
ANEST IWATA ITALIA S.r.l.
46, Corso Vigevano 10155, Torino
• ITALY
Tel. diretto +39 011 - 24 80 868 Fax: +39 011 - 85 19 44
info@anest-iwata.it
www.anest-iwata.it
Cormack ANEST IWATA
Unit 3, 10 Boden Road,
SEVEN HILLS NSW 2147
Tel: +61 2 9853 2000
Fax: +61 2 9853 2090
info@anest-iwata.com.au
ANEST IWATA Iberica
Calle de Les Teixidores, 3-5
08918 - Badalona (Barcelona)
Tel.:+34 933 20 59 93
info@anest-iwata.es
• USA
Fax: +1 513.755.0888
www.anestiwata.com
• AUSTRALIA
www.anest-iwata.com.au
www.anest-iwataeu.com/airgunsa
This AIR GUNSA spray guns kit complies to ATEX regulations 94/9/EC,
protection level:II 2 G X Suitable for using Zones 1 and 2.
X marking: Any static electricity discharge from the spray gun is to be diverted to the ground via the conductive air hose as stipulated.
Max. working air pressure:
Noise Level (LAeqT);
Max. Temperature range:
7.0 bar (100 PSI)
77.6 dB (A) *
5 ~ 40 °C
Air connection:
Fluid connection:
Weight g (lbs):
G 1/4”M
G 1/4”F
517 (1.14)
Model
Model
Test
Authority
Date
AZ2 HTE2
Transfer Efficiency according to EN 13966-1
IPA Fraunhofer Institut
28/03/2008
Transfer efficiencies achieved with the materials detailed in the test report were:
Air Gunsa S.r.l.
46, Corso Vigevano 10155 Torino • ITALY
Tel. +39 011 - 24 80 868
Fax +39 011 - 22 74 406
THREE COAT SYSTEM
PRIMER
BASECOAT
CLEARCOAT
87 %
83 %
74 %
Nozzle Aircap Air pressure Fluid
Air
Pattern
Orifice
set Mark at gun inlet output consumption
Width
Ø mm (in)
bar (PSI) ml/min Nl/min (cfm) mm (in)
AZ3 HTE2 / AZ3 HTE2 AV Gravity feed
AZ3 HTE2 1.0 1.0 (0.039)
80 200 (7.06) 180 (7.08)
10-15
AZ3 HTE2 1.3 1.3 (0.051) HTE
140 200 (7.06) 240 (9.44)
2.0 (29) 160 200 (7.06) 260 (10.23)
AZ3 HTE2 1.5 1.5 (0.059)
AZ3 HTE2 1.8 1.8 (0.070) 18-20
250 215 (7.59) 300 (11.81)
AZ3 HTE2 2.0 2.0 (0.079) HTE
300 215 (7.59) 340 (13.38)
AZ3 HTE2 2.5 2.5 (0.098) 25 HTE
450 280 (9.89) 360 (14.17)
AZ3 HTE2 2.8 2.8 (0.110) 28-30
540 300 (10.59) 380 (14.96)
3.0 (44)
HTE
AZ3 HTE2 3.0 3.0 (0.118)
560 300 (10.59) 400 (15.74)
AZ3 HTE2 3.5 3.5 (0.138) 35 HTE
600 300 (10.59) 420 (16.53)
AZ3 HTE2 HVLP **
AZ3 HTE2 HVLP 1.3 (0.051)
280 (11.0)
2.0 (30) 150
AZ3 HTE2 HVLP 1.5 (0.059)
185
290 (11.4)
340 (12.0)
HVLP
AZ3 HTE2 HVLP 1.8 (0.070)
215
340 (13.4)
Air cap press
0.7 bar (10psi) 240
AZ3 HTE2 HVLP 2.0 (0.079)
360 (14.2)
** Max gun inlet pressure 2.0bar (30psi) to achieve 10psi air cap
pressure for HVLP mandated areas
Certification available on www.airgunsa.com
2. Always wear protective gear (safety glasses, mask, gloves) to avoid
inflammation of eyes and skin.
In case of any physical discomfort, immediately seek medical advice.
3. Wear earplugs if necessary.
Noise level can exceed 85dB(A), depending on operating conditions and
painting site.
4. Pulling the trigger many times during operation, may cause carpal
tunnel syndrome. Always rest, in case of tiredness.
IMPROPER USE
1. Never point gun towards people or animals.
2. Never exceed maximum working pressure or maximum operating
Temperature
4. Tip of fluid needle set has a sharp point.
Do not touch the tip during maintenance to avoid accidents.
5. Never use this gun to spray foods or chemicals.
Otherwise, foreign substance, could cause corrosion of fluid passages
which could adversely affect health.
HOW TO USE
CAUTION
- Use clean air filtered through air dryer and air filter.
- When using this gun for the first time after purchase, adjust fluid needle packing set, spray cleaner to clean fluid passages and remove rust
preventive oil.
1. Firmly connect an air hose to air nipple 1/4”.
2. Firmly connect a suitable cup to fluid nipple.
FIRE AND EXPLOSION
4. Pour paint into container, test spray, adjust fluid output and pattern width.
1. Never use the following HALGOGENATED HYDROCARBON SOLVENTS:
which can cause cracks or dissolution of gun body (aluminium) due to
chemical reaction. UNSUITABLE SOLVENTS: methyl chloride, dichloromethane, 1.2-dichloroethane, carbon tetrachloride, trichloroethylene,
1.1.1-trichloroethane
HOW TO OPERATE
2. Sparks and open flames are strictly prohibited. Paints can be highly
flammable and can cause fire.Do not expose to open flames, electrical
goods, cigarettes etc.
ANEST IWATA Group
3. Always release air and fluid pressure before cleaning, disassembling
or servicing.
Otherwise, remaining pressure can cause bodily injury due
to improper operation or scattering of cleaning liquid.
SAFETY WARNING
3. Securely ground spray gun using conductive air hose. (Less than 1M Ù )
Always ensure that the spray gun is earthed correctly.
Manufactured by: AIR GUNSA s.r.l, 46 Corso Vigevano 10155 Torino - Italy
W5AZ3HTE2_Rev.00
PROTECTION OF HUMAN BODY
1. Use in a well-ventilated site, using a spray booth.
Poor ventilation can cause organic solvent poisoning and fire.
* Measuring point: 1m backwards from gun, 1.6m height
ANEST IWATA U.K.
Unit 10 Little End Road - Eaton Socon
St. Neots - CAMBRIDGESHIRE
• U.K.
PE19 8JH
Tel.: +44 (0) 1480 405419
Fax: +44 (0) 1480 217610
enquiries@anest-iwata.co.uk www.anest-iwata.co.uk
Quality Air Spray Guns Since 1944
Before use, adjustment or maintenance, it is important
to read this instruction manual very carefully. This manual
must be stored in a safe place for any future reference.
TECHNICAL SPECIFICATIONS
ANEST IWATA Scandinavia
Ögärdesvägen 6C, 433 30 PARTILLE
• SWEDEN
Tel. +46 (0)31 - 340 28 60
Fax +46 (0)31 - 340 28 69
info@anest-iwata.se
www.anest-iwata.se
• FRANCE
Fax +33 (0)4 - 74 94 34 39
www.anest-iwata.fr
GB
ALWAYS observe WARNINGS and CAUTIONS in this
instruction manual.
• SPAIN
Fax.:+34 933 20 59 65
www.anest-iwata.es
ANEST IWATA Europe S.r.l.
NIEDERLASSUNG DEUTSCHLAND
Dorfäckerstr. 23/1, 74248 Ellhofen
• GERMANY
Telefon: +49 (0) 7134- 917368 Fax: +49 (0) 7134 - 917378
Handy: +49 (0) 172 - 62 74 542
info@anest-iwata.de
www.anest-iwata.de
ANEST IWATA France
25 rue de Madrid
38070 St Quentin Fallavier
Tél. +33 (0)4 - 74 94 59 69
info@anest-iwata.fr
SPRAY GUN AZ3 HTE2, AZ3 HTE2 AV, AZ3 HTE2 HVLP
HEADQUARTERS: ANEST IWATA Corporation
3176, Shinyoshida-cho, Kohoku-ku - Yokohama, 223-8501 JAPAN
3. Flush fluid passages with a compatible solvent.
Suggested atomizing air pressure is 2.0 to 3.0 bar (29 to 44 PSI) at gun
inlet.
Recommended paint viscosity differs according to paint property and
painting conditions. 12 to 23 sec. / Ford cup#4 is recommended.
Set the spray distance from the gun to the work piece, as near as possible within the range of 100-200 mm (3.9-7.9 in).
MAINTENANCE & INSPECTION TROUBLESHOOTING
CAUTION
-
1. Pour remaining paint into another container. Clean fluid passages and
air cap set. Place a small amount of cleaner into the cup and flush out the
fluid passages. NOTE: DISCONNECT ATOMIZING AIR
DO NOT ATOMIZE CLEANING SOLUTION.
- INCOMPLETE CLEANING CAN CAUSE PATTERN SHAPE DEFECTS.
ESPECIALLY CLEAN FULLY AND PROMPTLY AFTER USE WITH TWOCOMPONENT PAINT.
DESCRIPTION
GUN DOES NOT SPRAY
- Make sure you do not damage tip of fluid nozzle or seat section.
- Never use spare parts that are not Air Gunsa originals.
Fluid adj. knob closed.
Tip hole of nozzle obstructed.
Paint filter obstructed.
Non drip obstructed.
Check and adjust.
Check and clean.
Check and clean.
Check and clean.
INTERMITTENT SPRAY PATTERN
- Air escapes from fluid nozzle.
Check , clean & replace if
necessary.
- Air escapes from fluid needle
packing.
Tighten.
- Air escapes from cup joint or
Tighten.
fluid hose joint .
- Dirt inside air cap.
Clean.
DEFECTIVE SPRAY PATTERN
2. Clean each section with brush soaked with cleaner and wipe out with
waste cloth.
- Dirty nozzle or air cap.
Clean carefully.
Nozzle or air cap has been
damaged.
- NEVER IMMERSE THE SPRAY GUN COMPLETELY IN SOLVENT, AS IT
CAN DAMAGE PARTS.
Replace If damaged.
- Fluid nozzle is loose
Tighten.
- Paint viscosity too high or
too low.
Dilute paint or increase
viscosity
- Fluid output too high or
too low.
Adjust fluid adj. knob to
reduce or increase.
- Fluid nozzle seat or needle set
dirty, damaged or worn.
Clean or replace if necessary.
- Loose fluid needle adj. knob.
Adjust.
LEAKING
3. Before disassembly, clean fluid passages.
a. Disassemble fluid nozzle, while keeping fluid needle pulled (triggering) in order to protect its seat section.
b. Disassemble fluid needle set. (only when strictly necessary)
c. Remove the fluid adj. knob and needle spring, extracting the spring
and fluid needle set, from the back of fluid adj. guide set still assembled on the gun body.
- Fluid needle spring is worn.
Replace.
- Loose fluid nozzle.
Tighten.
- Needle packing set loose, too
tight, dirty or worn.
Adjust, clean or replace.
AIR ESCAPES FROM AIR CAP
- Air valve, air valve seat or air Clean or replace if necesvalve spring dirty or damaged. sary.
DECLARATION OF CONFORMITY
We AIR GUNSA s.r.l. - Corso Vigevano, 46 - 10155 Torino - Italy declare, under our
sole responsibility, that the product:
Leakage from fluid nozzle set and fluid needle set seat sections.
Replace fluid nozzle set and fluid needle set, if leakage does not stop
after cleaning them. If you replace fluid nozzle or fluid needle only, match
them carefully and make sure there is no further leakage.
AZ3 HTE2 SPRAY GUN series
to which this declaration relates, is in conformity with European ATEX Directive
94/9/CE for use in zone 1 and zone 2 and Machinery Directive 98/37/CE.
According with the following international requirements: EN 1127-1, EN 292-2 and
EN 1953.
Name and position of issuer: Mr. Marco G. VICENTINI, Managing Director
Firma:
data: 04/04/2008
This is an original CE declaration of conformity issued by AIR GUNSA s.r.l.
Other copies are considered not valid
2
SPARE
InstructionPARTS
Manual LIST
Air cap
Fluid Nozzle
Nozzle holder
Pattern adjustment set
Fluid needle adjustment knob
Needle guide
Needle spring
Fluid needle
Needle packing nut
Air valve set
Air valve spring
GB
Ref. 1
Ref. 2
Ref. 3
Ref. 5
Ref. 6
Ref. 7
Ref. 8
Ref. 9
Ref. 10
Ref. 11
Ref. 11-1
Air valve shaft
Ref. 11-2
Air valve seat
Ref. 11-3
Trigger stud
Ref. 12
Trigger
Ref. 13
Air flow control valve (AZ3HTE2 AV) Ref. 14-1
Plug
Ref. 14-2
Threaded bushing
Ref. 15
Screw
Ref. 16-1
Plug
Ref. 16-2
Air nipple
Ref. 17
MAINTENANCE & INSPECTION TROUBLESHOOTING
CAUTION
-
1. Pour remaining paint into another container. Clean fluid passages and
air cap set.Spray a small amount of cleaner to clean fluid passages.
- INCOMPLETE CLEANING CAN CAUSE PATTERN SHAPE DEFECTS.
ESPECIALLY CLEAN FULLY AND PROMPTLY AFTER USE WITH TWOCOMPONENT PAINT.
DESCRIPTION
GUN DOES NOT SPRAY
- Make sure you do not damage tip of fluid nozzle or seat section.
- Never use spare parts that are not Air Gunsa originals.
Fluid adj. knob closed.
Tip hole of nozzle obstructed.
Paint filter obstructed.
Non drip obstructed.
Check and adjust.
Check and clean.
Check and clean.
Check and clean.
INTERMITTENT SPRAY PATTERN
- Air escapes from fluid nozzle.
Check , clean & replace if
necessary.
- Air escapes from fluid needle
packing.
Tighten.
- Air escapes from cup joint or
Tighten.
fluid hose joint .
- Dirt inside air cap.
Clean.
DEFECTIVE SPRAY PATTERN
2. Clean each section with brush soaked with cleaner and wipe out with
waste cloth.
- Dirty nozzle or air cap.
Clean carefully.
Nozzle or air cap has been
damaged.
- NEVER IMMERSE THE SPRAY GUN COMPLETELY IN SOLVENT, AS IT
CAN DAMAGE PARTS.
Replace If damaged.
- Fluid nozzle is loose
Tighten.
- Paint viscosity too high or
too low.
Dilute paint or increase
viscosity
- Fluid output too high or
too low.
Adjust fluid adj. knob to
reduce or increase.
- Fluid nozzle seat or needle set
dirty, damaged or worn.
Clean or replace if necessary.
- Loose fluid needle adj. knob.
Adjust.
LEAKING
3. Before disassembly, clean fluid passages.
a. Disassemble fluid nozzle, while keeping fluid needle pulled (triggering) in order to protect its seat section.
b. Disassemble fluid needle set. (only when strictly necessary)
c. Remove the fluid adj. knob and needle spring, extracting the spring
and fluid needle set, from the back of fluid adj. guide set still assembled on the gun body.
- Fluid needle spring is worn.
Replace.
- Loose fluid nozzle.
Tighten.
- Needle packing set loose, too
tight, dirty or worn.
Adjust, clean or replace.
AIR ESCAPES FROM AIR CAP
- Air valve, air valve seat or air Clean or replace if necesvalve spring dirty or damaged. sary.
DECLARATION OF CONFORMITY
We AIR GUNSA s.r.l. - Corso Vigevano, 46 - 10155 Torino - Italy declare, under our
sole responsibility, that the product:
Leakage from fluid nozzle set and fluid needle set seat sections.
Replace fluid nozzle set and fluid needle set, if leakage does not stop
after cleaning them. If you replace fluid nozzle or fluid needle only, match
them carefully and make sure there is no further leakage.
AZ3 HTE2 SPRAY GUN series
to which this declaration relates, is in conformity with European ATEX Directive
94/9/CE for use in zone 1 and zone 2 and Machinery Directive 98/37/CE.
According with the following international requirements: EN 1127-1, EN 292-2 and
EN 1953.
Name and position of issuer: Mr. Marco G. VICENTINI, Managing Director
Firma:
data: 04/04/2008
This is an original CE declaration of conformity issued by AIR GUNSA s.r.l.
Other copies are considered not valid
2
SPARE
InstructionPARTS
Manual LIST
Air cap
Fluid Nozzle
Nozzle holder
Pattern adjustment set
Fluid needle adjustment knob
Needle guide
Needle spring
Fluid needle
Needle packing nut
Air valve set
Air valve spring
GB
Ref. 1
Ref. 2
Ref. 3
Ref. 5
Ref. 6
Ref. 7
Ref. 8
Ref. 9
Ref. 10
Ref. 11
Ref. 11-1
Air valve shaft
Ref. 11-2
Air valve seat
Ref. 11-3
Trigger stud
Ref. 12
Trigger
Ref. 13
Air flow control valve (AZ3HTE2 AV) Ref. 14-1
Plug
Ref. 14-2
Threaded bushing
Ref. 15
Screw
Ref. 16-1
Plug
Ref. 16-2
Air nipple
Ref. 17
Instruction Manual
Contacts:
ANEST IWATA Europe S.r.l.
46, Corso Vigevano 10155, Torino • ITALY
Direct Tel. +39 011 - 22 74 402
Fax +39 011 - 22 74 406
info@anest-iwataeu.com
www.anest-iwataeu.com
ANEST IWATA USA, Inc.
9920 Windisch Road,
West Chester, OH 45069
Tel: +1 513.755.3100
Toll Free: 800.440.0282
inquiry@anestiwata.com
ANEST IWATA ITALIA S.r.l.
46, Corso Vigevano 10155, Torino
• ITALY
Tel. diretto +39 011 - 24 80 868 Fax: +39 011 - 85 19 44
info@anest-iwata.it
www.anest-iwata.it
Cormack ANEST IWATA
Unit 3, 10 Boden Road,
SEVEN HILLS NSW 2147
Tel: +61 2 9853 2000
Fax: +61 2 9853 2090
info@anest-iwata.com.au
ANEST IWATA Iberica
Calle de Les Teixidores, 3-5
08918 - Badalona (Barcelona)
Tel.:+34 933 20 59 93
info@anest-iwata.es
• USA
Fax: +1 513.755.0888
www.anestiwata.com
• AUSTRALIA
www.anest-iwata.com.au
www.anest-iwataeu.com/airgunsa
This AIR GUNSA spray guns kit complies to ATEX regulations 94/9/EC,
protection level:II 2 G X Suitable for using Zones 1 and 2.
X marking: Any static electricity discharge from the spray gun is to be diverted to the ground via the conductive air hose as stipulated.
Max. working air pressure:
Noise Level (LAeqT);
Max. Temperature range:
7.0 bar (100 PSI)
77.6 dB (A) *
5 ~ 40 °C
Air connection:
Fluid connection:
Weight g (lbs):
G 1/4”M
G 1/4”F
517 (1.14)
Model
Model
Test
Authority
Date
AZ2 HTE2
Transfer Efficiency according to EN 13966-1
IPA Fraunhofer Institut
28/03/2008
Transfer efficiencies achieved with the materials detailed in the test report were:
Air Gunsa S.r.l.
46, Corso Vigevano 10155 Torino • ITALY
Tel. +39 011 - 24 80 868
Fax +39 011 - 22 74 406
THREE COAT SYSTEM
PRIMER
BASECOAT
CLEARCOAT
87 %
83 %
74 %
Nozzle Aircap Air pressure Fluid
Air
Pattern
Orifice
set Mark at gun inlet output consumption
Width
Ø mm (in)
bar (PSI) ml/min Nl/min (cfm) mm (in)
AZ3 HTE2 / AZ3 HTE2 AV Gravity feed
AZ3 HTE2 1.0 1.0 (0.039)
80 200 (7.06) 180 (7.08)
10-15
AZ3 HTE2 1.3 1.3 (0.051) HTE
140 200 (7.06) 240 (9.44)
2.0 (29) 160 200 (7.06) 260 (10.23)
AZ3 HTE2 1.5 1.5 (0.059)
AZ3 HTE2 1.8 1.8 (0.070) 18-20
250 215 (7.59) 300 (11.81)
AZ3 HTE2 2.0 2.0 (0.079) HTE
300 215 (7.59) 340 (13.38)
AZ3 HTE2 2.5 2.5 (0.098) 25 HTE
450 280 (9.89) 360 (14.17)
AZ3 HTE2 2.8 2.8 (0.110) 28-30
540 300 (10.59) 380 (14.96)
3.0 (44)
HTE
AZ3 HTE2 3.0 3.0 (0.118)
560 300 (10.59) 400 (15.74)
AZ3 HTE2 3.5 3.5 (0.138) 35 HTE
600 300 (10.59) 420 (16.53)
AZ3 HTE2 HVLP **
AZ3 HTE2 HVLP 1.3 (0.051)
280 (11.0)
2.0 (30) 150
AZ3 HTE2 HVLP 1.5 (0.059)
185
290 (11.4)
340 (12.0)
HVLP
AZ3 HTE2 HVLP 1.8 (0.070)
215
340 (13.4)
Air cap press
0.7 bar (10psi) 240
AZ3 HTE2 HVLP 2.0 (0.079)
360 (14.2)
** Max gun inlet pressure 2.0bar (30psi) to achieve 10psi air cap
pressure for HVLP mandated areas
Certification available on www.airgunsa.com
2. Always wear protective gear (safety glasses, mask, gloves) to avoid
inflammation of eyes and skin.
In case of any physical discomfort, immediately seek medical advice.
3. Wear earplugs if necessary.
Noise level can exceed 85dB(A), depending on operating conditions and
painting site.
4. Pulling the trigger many times during operation, may cause carpal
tunnel syndrome. Always rest, in case of tiredness.
IMPROPER USE
1. Never point gun towards people or animals.
2. Never exceed maximum working pressure or maximum operating
Temperature
4. Tip of fluid needle set has a sharp point.
Do not touch the tip during maintenance to avoid accidents.
5. Never use this gun to spray foods or chemicals.
Otherwise, foreign substance, could cause corrosion of fluid passages
which could adversely affect health.
HOW TO USE
CAUTION
- Use clean air filtered through air dryer and air filter.
- When using this gun for the first time after purchase, adjust fluid needle packing set, spray cleaner to clean fluid passages and remove rust
preventive oil.
1. Firmly connect an air hose to air nipple 1/4”.
2. Firmly connect a suitable cup to fluid nipple.
FIRE AND EXPLOSION
4. Pour paint into container, test spray, adjust fluid output and pattern width.
1. Never use the following HALGOGENATED HYDROCARBON SOLVENTS:
which can cause cracks or dissolution of gun body (aluminium) due to
chemical reaction. UNSUITABLE SOLVENTS: methyl chloride, dichloromethane, 1.2-dichloroethane, carbon tetrachloride, trichloroethylene,
1.1.1-trichloroethane
HOW TO OPERATE
2. Sparks and open flames are strictly prohibited. Paints can be highly
flammable and can cause fire.Do not expose to open flames, electrical
goods, cigarettes etc.
ANEST IWATA Group
3. Always release air and fluid pressure before cleaning, disassembling
or servicing.
Otherwise, remaining pressure can cause bodily injury due
to improper operation or scattering of cleaning liquid.
SAFETY WARNING
3. Securely ground spray gun using conductive air hose. (Less than 1M Ù )
Always ensure that the spray gun is earthed correctly.
Manufactured by: AIR GUNSA s.r.l, 46 Corso Vigevano 10155 Torino - Italy
W5AZ3HTE2_Rev.00
PROTECTION OF HUMAN BODY
1. Use in a well-ventilated site, using a spray booth.
Poor ventilation can cause organic solvent poisoning and fire.
* Measuring point: 1m backwards from gun, 1.6m height
ANEST IWATA U.K.
Unit 10 Little End Road - Eaton Socon
St. Neots - CAMBRIDGESHIRE
• U.K.
PE19 8JH
Tel.: +44 (0) 1480 405419
Fax: +44 (0) 1480 217610
enquiries@anest-iwata.co.uk www.anest-iwata.co.uk
Quality Air Spray Guns Since 1944
Before use, adjustment or maintenance, it is important
to read this instruction manual very carefully. This manual
must be stored in a safe place for any future reference.
TECHNICAL SPECIFICATIONS
ANEST IWATA Scandinavia
Ögärdesvägen 6C, 433 30 PARTILLE
• SWEDEN
Tel. +46 (0)31 - 340 28 60
Fax +46 (0)31 - 340 28 69
info@anest-iwata.se
www.anest-iwata.se
• FRANCE
Fax +33 (0)4 - 74 94 34 39
www.anest-iwata.fr
GB
ALWAYS observe WARNINGS and CAUTIONS in this
instruction manual.
• SPAIN
Fax.:+34 933 20 59 65
www.anest-iwata.es
ANEST IWATA Europe S.r.l.
NIEDERLASSUNG DEUTSCHLAND
Dorfäckerstr. 23/1, 74248 Ellhofen
• GERMANY
Telefon: +49 (0) 7134- 917368 Fax: +49 (0) 7134 - 917378
Handy: +49 (0) 172 - 62 74 542
info@anest-iwata.de
www.anest-iwata.de
ANEST IWATA France
25 rue de Madrid
38070 St Quentin Fallavier
Tél. +33 (0)4 - 74 94 59 69
info@anest-iwata.fr
SPRAY GUN AZ3 HTE2, AZ3 HTE2 AV, AZ3 HTE2 HVLP
HEADQUARTERS: ANEST IWATA Corporation
3176, Shinyoshida-cho, Kohoku-ku - Yokohama, 223-8501 JAPAN
3. Flush fluid passages with a compatible solvent.
Suggested atomizing air pressure is 2.0 to 3.0 bar (29 to 44 PSI) at gun
inlet.
Recommended paint viscosity differs according to paint property and
painting conditions. 12 to 23 sec. / Ford cup#4 is recommended.
Set the spray distance from the gun to the work piece, as near as possible within the range of 100-200 mm (3.9-7.9 in).