Malaga II / IIE Storage Water

Malaga II / IIE
Storage Water
Heater
All gas appliances must be installed and/or
commissioned by corgi registered persons.
Installation
&
Operation Instructions
PROPEX HEATSOURCE LTD
Unit 5, Second Avenue Business Park,
Millbrook, Southampton. SO15 0LP
Tel: 023 8052 8555
Fax: 023 8052 8800
Website: www.propexheatsource.co.uk
Email: info@propexheatsource.co.uk
E
FF O
EN
NG
G II N
NE
EE
ER
RE
ED
D
OR
R
C
&
R
CO
OM
M FF O
OR
R TT
&
RE
E LL II A
AB
B II LL II TT Y
Y
702 issue D
230VAC WIRING DIAGRAM
USER INSTRUCTIONS
- The Propex Malaga II is for use on L.P.Gas only
- The Propex Malaga IIE is for use on both L.P.Gas and mains electricity
Colour Key
O Orange
BK Black
W White
P Purple
BU Blue
R Red
G/Y Green / Yellow
On initial operation or when the system has been drained, refill the system with
water and flush out by turning on each hot tap until a steady flow of water is
obtained. If a water filter is fitted it should be changed at the recommended
intervals.
Check that the Gas and Electricity supplies are turned on.
OPERATION
Gas - Switch on the heater. Initially the red light will come on followed by the
green light which will stay lit as long as the burner is alight. If the gas does not
light and the red light comes back on - switch off - wait 10 seconds and switch
on again. Several attempts may initially be required for purging.
Note: When the water has reached the preset temperature no lights will show.
As the water cools or is drawn off the heater will automatically relight and the
green light will come on until the water has again reached temperature.
12VDC WIRING DIAGRAM
If at any time the light comes on indicating a fault condition, wait 3 minutes
before attempting to relight. If the fault persists, check that:
(i) The gas supply has not run out
(ii) The battery is fully charged
Electricity - The Malaga IIE has a 230v electric element which can be used
independently or in addition to the gas burner.
Note: A 12v D.C. supply must be connected at all times.
Water - This appliance must not be connected directly to the Mains Water
Supply.
Battery - The heater is designed to operate on a 12v D.C. supply. Should the
supply drop to 9 volts the heater will shut off for safety. Turn off the heater and
recharge the battery before reusing the heater.
When not in use the heater should be drained as follows:
To drain
Turn knob clockwise
and open hot water tap
SWITCH HARNESS
+ 12
Volts
Winter operation - When using the heater in Winter ensure that the flue is not
blocked by snow or fallen leaves etc.
12v CONNECTION
Blue = + (Positive)
White = - (Negative)
0
Volts
Drain port
-2-
-7-
CONNECTING THE WATER HEATER
FAULT FINDING - CHECK LIST
1 - WATER
1 - Check that the following supplies of gas, water and electricity are
available
Use half reinforced, food quality, opaque or similar pipework only. The “Hot”
and “Cold” connections are clearly marked and it is important that they are
connected correctly. If the plastic inlet connection supplied with the heater is
removed it is important that only a plastic replacement is used. The outlet
connection at the top of the tank must not be removed as this houses an
additional internal tube which provides the air space for expansion inside the
tank. The water pressure must not exceed 1.3 Bar.
DO NOT CONNECT THIS APPLIANCE TO THE A MAINS WATER SUPPLY
Drain / Pressure Relief Valve - Drill the appropriate sized hole in the floor
close to the heater. Fit a piece of hose from the drain through the floor and
seal the floor with silicon rubber or similar material.
Water Systems - The heater will operate satisfactorily on either system where
the pump is controlled by a tap, microswitches or a pressure switch.
2 - GAS
The gas connection is 8mm and suitable compression fitting is required. An
isolation tap should be fitted near to the heater and any unsupported pipework
secured. It is recommended that a gas drop hole is positioned near to the
heater. All gas connections should be carried out by a corgi registered person.
Gas
Water
Battery /
Transformer
Malaga IIE only
Butane - 28/30 mbar or Propane 37mbar
Turn on a hot tap and check for a steady supply of water
12V d.c. supply
Colour code - Blue 12v - White OV
Mains electricity 230v - A.C. 50Hz (fused 5A)
2 - Heater not working - No L.E.D. lit
(i) Disconnect 9 way plug from heater and remove controls cover.
(ii) Check for continuity between contacts 1 & 2 on 9 way socket
If no continuity check:
a) Manual reset button.
b) Fuse.
c) Wiring Contacts.
d) Continuity across thermostats.
3 - Replace 9 way plug and switch heater on
(i) Check for 12v at 1
(ii) Check for supply at solenoid 10 - 12V
If yes change solenoid, if no change PCB
4 - No spark at burner
3 - ELECTRICITY
(i) Check ignition lead, electrode and burner
(ii) If items above correct - change PCB
Fit the wall switch in the chosen position and route the wiring to the heater.
Connect the 12v supply to the switch and plug into the heater.
5 - Mains element - Malaga IIE only
Note: Check that the polarity is correct.
Malaga IIE only - The appliance should be connected to a 230v AC - 5 amp
fused spur.
(I) Check continuity terminal block to printed circuit board
(ii) Check continuity printed circuit board to element - if no replace PCB
(iii) Check element resistance (70 OHMS)
Note: This appliance must be earthed.
Note: There is an element overheat cut-out switch in the element base
-4-
-5-
TECHNICAL DATA
INSTALLATION
Dimensions
Height - 250mm
Width - 285mm
Depth - 520mm
Installation and servicing of this appliance must only be carried out by corgi
registered persons.
Weight empty
9.3kg
Prior to installation check that the gas supply pressures & type are compatible.
(see data plate on appliance)
Inward protrusion from wall
480mm
This appliance must be installed in accordance with the current regulations. In
the United Kingdom the installation must be in accordance with BS6501 Pt 1
1978, BS5482 Pts 1 & 2 1977 and BS5440 Pt 2 1990.
Clearances required for installation and servicing, as seen from the inside.
Left Hand Side
Right Hand Side
Top
240mm
100mm
5mm
The Malaga II Water Heater is designed to be floor mounted and flues through
a vertical section on external wall. Normally the heater would be fitted in a
bedbox or locker . Structural sections within the vehicle should not be
damaged (see technical information for details).
Water
Maximum Supply Pressure
Pressure Relief Valve Setting
Working Pressure
1.3 BAR
3.0 BAR
2.0 BAR
Flue - Using masking tape, fix the template to the inside of the vehicle and drill
a pilot hole at position X. Remove the template and tape it to the outside of the
vehicle ensuring that the template is square and that the centre lines up with
the hole drilled from the inside.
Gas
Heat Input
Pressure Setting
CAT I3+
Injector
Gas Connection
1.15kw / 80g/h
Propane 37 mbar
Butane 28 mbar
BRAY 960 / 40
8mm O.D.
Drill a 10mm hole at positions A and, using a jigsaw, cut out the hole. The hole
in the wall must be battened to secure the inner and outer skins.
Malaga II
Malaga IIE
12v D.C.
12v D.C.
230v 50hz 5a fuse
Electricity
ELECTRODE SETTING
Note: When battening the finished hole must be 240mm x 135mm. Run a
bead of silicon rubber or similar seal around the edge of the ear side of the flue
cover, position into cut-out in wall and secure with screws.
Water Heater - Remove the floor
covering (e.g. carpet etc) from the area
where the eater heater will stand 450mm inward from the wall and
320mm wide. Draw a line on the floor
from the centre of the flue 600mm into
the vehicle.
Slide through the flue seals until the
stop position is reached. Make sure
both flue and air intake pass through
the lip seals.
Line up the marker on the rear of the
heater with the line on the floor and
screw the heater to the floor.
-6-
-3-