MM-10XP
DATASHEET
X-400C : Compact Cinema Subwoofer
Dimensions
31.00” w x 20.65” h x 20.79” d
(787 mm x 525 mm x 528 mm)
Weight 85 lbs (38.6 kg)
Enclosure Premium birch plywood
Finish Low-gloss, black textured
Protective Grille Optional grille frame with
black cloth
20.79
20.79
[528mm]
mm]
[528
10.10
10.10
[257mm]
mm]
[257
10.70
10.70
[272mm]
mm]
[272
31.00
31.00
[787mm]
mm]
[787
20.79
20.79
[528mm]
mm]
[528
20.65
20.65
[525mm]
mm]
[525
10.10
10.10
[257mm]
mm]
[257
10.70
10.70
[272mm]
mm]
[272
31.00
31.00
[787mm]
mm]
[787
Part of Meyer Sound’s EXP cinema series,
the X‑400C compact subwoofer boosts lowfrequency headroom in cinema applications
and other fixed installations. The linear,
self-powered X‑400C offers similar sonic
characteristics as the X‑800C subwoofer —
low-frequencies down to 20 Hz, clean, punchy
transients, and excellent phase coherence —
though in a more compact cabinet that can be
installed singly or as multiple units.
The X‑400C is comprised of a single 18-inch
low-frequency, long-excursion cone driver
housed in an optimally tuned, vented cabinet
and powered by a single-channel amplifier.
Onboard processing includes driver protection
circuitry, low-pass filtering, and correction
filters for flat phase and frequency responses.
The IntelligentAC™ power supply affords
automatic voltage selection, EMI filtering, soft
current turn-on, and surge suppression.
The X‑400C integrates seamlessly with other
EXP cinema loudspeakers, including the
Acheron screen channel loudspeakers and HMS
Features & Benefits
[525mm]
mm]
[525
Meyer Sound’s optional RMS™ remote monitoring
system provides comprehensive monitoring of
system parameters on a Mac® or Windows®based computer.
The X‑400C cabinet is constructed of premium
birch plywood and coated with a low-gloss,
black-textured finish. The cabinet includes
attachment points for an optional grille frame
with black cloth.
Applications
High peak power output with
excellent transient reproduction
Flat amplitude and phase responses
for tonal accuracy
Extended low frequency range down
to 20 Hz
Integrates with Acheron Studio and
Acheron Designer screen channel
loudspeakers
Extremely low distortion for
exceptional low-frequency clarity
surround
loudspeakers.
20.65
20.65
Integrates with HMS-5, HMS‑10, and
HMS‑12 surround loudspeakers
Sound design suites
Small theatres and custom, private
theatres
Screening rooms
Mixing for postproduction facilities
Immersive surround applications
X-400C Specifications
Notes:
Acoustical
Coverage
Operating Frequency Range1
Frequency Response2
Phase Response
Maximum Peak SPL3
Dynamic Range
Varies with number of units and configuration
Transducer
Audio Input
Low Frequency One 18” long-excursion cone driver
Nominal impedance: 4 Ω
Type
Maximum Common Mode Range
Connectors
Input Impedance
Wiring
DC Blocking
CMRR
RF Filter
TIM Filter
Nominal Input Sensitivity
Input Level
Amplifier
AC Power
20 Hz – 200 Hz
23 Hz – 160 Hz ±4 dB
32 Hz – 175 Hz ±30°
130 dB
>110 dB
Type
Output Power4
Total Output
THD, IM, TIM
Load
Cooling
Connector
Voltage Selection
Safety Agency Rated Operating Range
Turn-on and Turn-off Points
Current Draw: Idle Current
Maximum Long-Term Continuous Current (>10 sec)
Burst Current (<1 sec)5
Maximum Instantaneous Peak Current
Inrush Current
RMS Network (optional)
Differential, electronically balanced
±15 V DC, clamped to earth for voltage transient protection
XLR 3-pin female input with XLR 3-pin male loop output
10 kΩ differential between pins 2 and 3
Pin 1: Chassis/earth through 220 kΩ, 1000 pF, 15 V clamped network
to provide virtual ground lift at audio frequencies
Pin 2: Signal +
Pin 3: Signal –
Case: Earth ground and chassis
Differential DC blocking up to the maximum common mode voltage
>50 dB, typically 80 dB (50 Hz – 500 Hz)
Common mode: 425 kHz; Differential mode: 142 kHz
Integral to signal processing (<80 kHz)
0 dBV (1.0 V rms, 1.4 V peak) continuous is typically the onset of
limiting for noise and music
Audio source must be capable of producing +20 dBV (10 V rms,
14 V peak) into 600 Ω to produce the maximum peak SPL over the
operating bandwidth of the loudspeaker
Single channel
450 W
900 W peak
<.02%
4Ω
Convection
1. Recommended maximum operating
frequency range. Response depends
on loading conditions and room
acoustics.
2. Free field measured with 1/3-octave
frequency resolution at 4 meters.
3. Measured with music referred to
1 meter, half-space loading.
4. Amplifier wattage rating based on
the maximum unclipped burst sinewave rms voltage the amplifier
will produce into the nominal load
impedance: 42 V rms (60 V peak)
into 4 ohms.
5. AC power cabling must be of
sufficient gauge so that under
burst current rms conditions, cable
transmission losses do not cause the
loudspeaker’s voltage to drop below
the specified operating range.
C
US
N775
X-400C — 04.213.022.01 A
powerCON 20 with loop output
Automatic, continuous range from 90–265 V AC
100–240 V AC, 50/60 Hz
90 V AC on, no turn-off, only fuse-protect above 265 V AC
0.26 A rms (115 V AC); 0.16 A rms (230 V AC); 0.30 A rms (100 V AC)
1.4 A rms (115 V AC); 0.7 A rms (230 V AC); 1.6 A rms (100 V AC)
2.7 A rms (115 V AC); 1.1 A rms (230 V AC); 3.0 A rms (100 V AC)
9 A peak (115 V AC); 6 A peak (230 V AC); 10 A peak (100 V AC)
10 A peak (115 V AC); 8 A peak (230 V AC); 10 A peak (100 V AC)
Equipped with two-conductor twisted-pair network, reporting
amplifier operating parameters to host computer
Copyright © 2013
Meyer Sound Laboratories Inc.
All rights reserved
meyer sound laboratories inc.
2832 San Pablo Avenue
Berkeley, CA 94702
T: +1 510 486.1166
F: +1 510 486.8356
techsupport@meyersound.com
www.meyersound.com
Architect Specifications
The loudspeaker shall be a self-powered, sub-bass
system with a single 18-inch low-frequency, longexcursion cone driver.
The loudspeaker shall incorporate internal processing
electronics and a single-channel amplifier. Burst power
shall be 450 watts (900 watts peak) with a nominal
4-ohm resistive load. Distortion (THD, IM, TIM) shall
not exceed 0.02 percent. The audio input shall be
electronically balanced with a 10 kOhm impedance and
accept a nominal 0 dBV (1 V rms) signal (20 dBV to
produce maximum SPL). Connectors shall be XLR 3-pin
male and female. RF filtering shall be provided, and
CMRR shall be greater than 50 dB (50 Hz – 500 Hz).
Performance specifications for a typical production unit
shall be as follows, measured at 1/3-octave resolution:
operating frequency range, 20 Hz to 200 Hz; phase
response, 32 Hz to 175 Hz ±30 degrees; maximum peak
SPL, 130 dB at 1 meter.
inrush during soft turn-on shall not exceed 10 A peak
at 115 V AC, 8 A peak at 230 V AC, and 10 A peak at
110 V AC. AC power connectors shall be powerCON 20
with loop output. The loudspeaker shall optionally
include an RMS remote monitoring system module.
The internal power supply shall perform automatic
voltage selection, EMI filtering, soft current turn-on,
and surge suppression. Power requirements shall be
nominal 100 V, 110 V or 230 V AC line current at 50
or 60 Hz. UL and CE operating voltage ranges shall be
200 to 240 V AC. The maximum long-term continuous
current draw (>10 sec) shall be 1.4 A rms at 115 V AC,
0.7 A rms at 230 V AC, and 1.6 A rms at 100 V AC. Current
Loudspeaker components shall be mounted in a premium
birch plywood enclosure with a low-gloss, blacktextured finish. Dimensions shall be 31.00 inches wide x
20.65 inches high x 20.79 inches deep (787 mm x 525 mm
x 528 mm). Weight shall be 85 lbs (38.6 kg).
The loudspeaker shall be the Meyer Sound X-400C.
DATASHEET
X-800C : High-Power Cinema Subwoofer
21.00
[533 mm]
28.17
[715 mm]
40.00
[1016 mm]
9.50
[241 mm]
31.00
[787 mm]
20.00
[508 mm]
0.62
[16 mm]
15.50
[394 mm]
Dimensions 31.00" w x 40.00" h x 21.00" d
(787 mm x 1016 mm x 533 mm)
Weight 221 lbs (100.24 kg)
Enclosure Premium birch plywood
Finish Low-gloss black textured finish
The Meyer Sound X-800 high-power
subwoofer is designed to provide very
low-frequencies with ample headroom in
critical applications. The X-800 Studio and
X-800C Cinema versions from the EXP line
of products excel in environments requiring
very low distortion, extended bandwidth
and extreme low frequency transients.
The X-800C is a linear, powerful selfpowered subwoofer offering excellent
phase coherence for smooth transitioning
from screen channels to low-frequency
effects (LFE), The X-800C delivers extended
low frequency output down to 20 Hz with
clear, punchy transients even at very high
levels.
The X-800C houses two Meyer Sound long
excursion, high efficiency 18-inch drivers
in an optimally tuned, vented cabinet. The
X-800C output rolls off well below 250 Hz,
avoiding any adverse comb filtering effects
that could be generated by the proximity
of other X-800C subwoofers when used in
arrays.
An integral two-channel class AB/H
amplifier with complementary MOSFET
output stages supplies a total output of
1240 Watts (2480 Watts peak), providing
the system with sufficient headroom to
accommodate lowest frequencies of the
most extreme digital soundtrack’s.
Each amplifier channel features TruPower®
limiting technology to maximize loudspeaker
reliability, minimize power compression and
extend component life. An Intelligent AC™
power supply affords automatic voltage
selection, EMI filtering, soft current turn-on
and surge suppression.
A laser-trimmed differential input with
high common-mode rejection enables long
line-level signal runs using shielded, twistedpair cable. As with all Meyer Sound selfpowered products, sophisticated onboard
features & benefits
processing includes phase and frequency
response correction filters. This selfpowered design not only assures consistent
results but also simplifies installation in
both new and existing rooms.
The X-800C subwoofer's premium birch
plywood cabinet is coated with a durable
textured low gloss finish. Meyer Sound’s
optional RMS™ remote monitoring system
provides comprehensive system monitoring
over a Windows-based network.
With a 30-year history of successful
solutions, Meyer Sound understands the
science of sound reproduction. Our selfpowered loudspeakers offer unsurpassed
intelligibility, power and clarity. And in
conjunction with a suite of powerful
integration tools, Meyer Sound is able to
offer a complete, dedicated cinema sound
solution that is designed to meet the
demands and opportunities of the next
generation of cinema sound.
applications
High peak power yields excellent transient
reproduction
Extremely low distortion for ultimate lowfrequency clarity
Extended low frequency range down to
20 Hz
Exceptionally reliable and durable
Motion picture theaters
Dub stages
Production and post production facilities
Soundtrack recording and mixing
X-800C specifications
Acoustical
Notes:
Operating Frequency Range1
Frequency Response2
Phase Response
Maximum Peak SPL3
Dynamic Range
20 Hz - 200 Hz
23 Hz - 160 Hz ±4 dB
32 Hz to 175 Hz ±30°
136 dB
>110 dB
1. Recommended maximum operating
frequency range. Response depends on
loading conditions and room acoustics.
2. Free field, measured with one-third
octave frequency resolution at 4
meters.
Coverage
360° (single unit); varies with number of units and configuration
Transducers
Low Frequency
3. Measured with music at 1 meter.
Two 18" cone drivers
Nominal impedance: 8 Ω
Voice coil size: 3"
Power-handling capability: 600 AES W4
4. Power handling is measured under
AES standard conditions: transducer
driven continuously for two hours with
band-limited noise signal having a 6
dB peak-average ratio.
Differential, electronically balanced
±15 V DC, clamped to earth for voltage transient protection
Female XLR input and male XLR loop output (integrates AC, audio
and network)
10 kΩ differential between pin 2 and 3
Pin 1: Chassis/earth through 220 kΩ, 1000 pF, 15 V clamp
network to provide virtual ground lift at audio frequencies
Pin 2: Signal +
Pin 3: Signal Case: Earth ground and chassis
None on input; DC blocked through signal processing
>50 dB, typically 80 dB (50 Hz - 500 Hz)
Common mode 425 kHz; Differential mode 142 kHz
Integral to signal processing (< 80 kHz)
Audio source must be capable of producing a minimum of +20 dB V
(10 V rms, 14 V pk) into 600 Ω inorder to produce maximum peak SPL
over the operating bandwidth of the loudspeaker
0 dB V (1 V rms, 1.4 V pk) continuous is typically the onset of limiting
for noise and music
5. Amplifier wattage rating is based
on the maximum unclipped burst
sine-wave rms voltage the amplifier
will produce into the nominal load
impedance. Both Channels 70 V rms
(100 V pk) into 8 ohms.
Audio Input
Type
Maximum Common Mode Range
Connectors
Input Impedance
Wiring
DC Blocking
CMRR
RF Filter
TIM Filter
Input Level
Nominal Input Sensitivity
Amplifier
Type
Output Power5
THD, IM, TIM
Load Capacity
Cooling
Complementary power MOSFET output stages (class AB/H)
1240 W (2480 Watts peak)
<0.02 %
8 Ω minimum impedance each channel
Forced air cooling, 2 internal fans (one low-speed and one reserve fan)
AC Power
Connector
Automatic Voltage Selection
Safety Agency Rated Operating Range
Turn-on and Turn-off Points
Current Draw:
Idle Current
Max Long-Term Continuous Current (>10 sec)
Burst Current (<1 sec)
Ultimate Short-Term Peak Current Draw
Inrush Current
RMS Network
(optional)
250 V AC NEMA L6-20 inlet or IEC 309 male inlet
Automatic, two ranges, each with high-low voltage tap
(uninterrupted)
95 V AC - 125 V AC; 208 V AC - 235 V AC; 50/60 Hz
85 V AC - 134 V AC; 165 V AC - 264 V AC; 50/60 Hz
X-800C — 04.087.010.02 B
0.640 A rms (115 V AC); 0.320 A rms (230 V AC); 0.850 A rms (100 V AC)
8 A rms (115 V AC); 4 A rms (230 V AC); 10 A rms (100 V AC)
15 A rms (115 V AC); 8 A rms (230 V AC); 18 A rms (100 V AC)
22 A pk (115 V AC); 11 A pk (230 V AC); 25 A pk (100 V AC)
<7 A (115 V AC & 230 V AC); 10 A pk (100 V AC)
Equipped for two-conductor twisted-pair network, reporting
all operating parameters ofamplifiers to system operator’s host
computer.
The loudspeaker shall incorporate internal processing
electronics and a two-channel amplifier. Each amplifier
channel shall be class AB/H with complementary MOSFET output
stages. Burst capability shall be 1240 watts total with nominal
8-ohm resistive load. Distortion (THD, IM, TIM) shall not exceed
0.02%. Protection circuits shall include TruPower limiting. The
audio input shall be electronically balanced with a 10 kOhm
impedance and accept a nominal 0 dBV (1 V rms) signal (20 dBV
to produce maximum SPL). Connectors shall be XLR type male
and female or VEAM all-in-one. RF filtering shall be provided,
and CMRR shall be greater than 50 dB (50 - 500 Hz).
meyer sound laboratories inc.
2832 San Pablo Avenue
Berkeley, CA 94702
T: +1 510 486.1166
F: +1 510 486.8356
techsupport@meyersound.com
www.meyersound.com
CE APPROVAL LABEL SMALL
30.050.035.04_E
KMK 2/25/08 ECO#11253
architect specifications
The loudspeaker shall be a self-powered, sub-bass system. The
transducers shall consist of two 18-inch cone drivers (3-inch
voice coil) each rated to handle 600 AES* watts.
Copyright ©2010
Meyer Sound Laboratories, Inc.
All rights reserved
Performance specifications for a typical production unit shall
be as follows, measured at 1/3-octave resolution: Operating
frequency range shall be 20 Hz to 200 Hz. Phase response shall
be ±30° from 35 Hz to 120 Hz. Maximum peak SPL shall be 136
dB at 1 meter.
The internal power supply shall perform automatic voltage
selection, EMI filtering, soft current turn-on and surge
suppression. Powering requirements shall be nominal 100 V,
110 V or 230 V AC line current at 50 Hz or 60 Hz. UL and CE
operating voltage ranges shall be 95 to 125 V AC and 208 to 235
V AC. Current draw during burst shall be 15 A rms at 115 V AC,
8 A rms at 230 V AC and 18 A rms at 100 V AC. Current inrush
during soft turn-on shall not exceed 7 A at 115 V AC. AC power
connectors shall be L6-20, IEC 309 male or VEAM all-in-one.
The loudspeaker shall optionally incorporate the electronics
module for Meyer Sound’s RMS remote monitoring system.
Loudspeaker components shall be mounted in a premium birch
plywood enclosure with a durable textured finish (optional
smooth medium-gloss black finish available). Dimensions shall
be 31.00" wide x 40.00" high x 21.33" deep (787 mm x 1016 mm
x 542 mm). Weight shall be 221 lbs (100.24 kg).
The loudspeaker shall be the Meyer Sound X-800C high-power
cinema subwoofer.
*Driven continuously for two hours with band-limited noise
signal having a 6 dB peak-average ratio.
DATASHEET
LF
900-LFC Compact Low-Frequency Control Element
Meyer Sound’s 900-LFC compact low-frequency
control element reproduces low frequencies at
high, continuous output levels with extremely
low distortion. The 900‑LFC offers the same
sonic linearity as Meyer Sound’s 1100-LFC
low-frequency control element in a smaller,
lighter cabinet, making it ideal for building
scalable systems to suit touring applications or
fixed installations of any size.
A newly-designed class D amplifier affords
unprecedented efficiency to the 900-LFC,
significantly lowering distortion while reducing
power consumption and operating temperature.
The onboard amplifier and control circuitry are
contained in a single, field-replaceable module.
In addition to pairing with LEOPARD™ systems,
the 900-LFC integrates easily with other Meyer
Sound loudspeaker systems, including LEO-M™,
LYON™, and ULTRA Series loudspeakers.
LEOPARD and 900-LFC can be driven by Meyer
Sound’s Galileo Callisto™ 616 array processor,
which
provides
matrix
routing,
alignment, and processing for array
components. To guarantee optimum
performance, systems with the 900‑LFC
should be designed with Meyer Sound’s
MAPP™ software. LEOPARD and 900‑LFC
loudspeakers work with Meyer Sound’s
RMS™ remote monitoring system, which
provides comprehensive monitoring
of system parameters from a Mac® or
Windows®-based computer.
The 900-LFC is available with or without
Meyer Sound’s QuickFly® rigging. When
equipped with the optional MRK‑900
rigging kit, the 900-LFC’s captive
GuideALinks™ allow it to be flown from
the MG‑LEOPARD/900 multipurpose
grid in LEOPARD arrays without a
transition frame. 900-LFCs can also be
flown separately as a subwoofer array with
variable splay angles from 0 to 5 degrees. The
MG‑LEOPARD/900 grid can also be used for
groundstacks with uptilt or downtilt.
Both versions of the 900-LFC can be
transported in stacks with the optional
MCF‑900 caster frame.
solutions
features & benefits
°° Compact cabinet with small footprint and
°° Self-powered for simplified setup and
°° Scalable low-frequency control for touring
°° High peak power output with extremely low
distortion
°° Stackable and flyable in regular and
cardioid arrays, with tilt and splay options
°° Clubs, theatres, houses of worship, corporate
°° Exceptional linearity, transient reproduction,
°° Integral pole-mount receptacle easily pairs the
°° Low-frequency complement for LEO-M,
extraordinary power-to-size ratio
and low-frequency clarity
increased reliability
subwoofer with ULTRA Series loudspeakers
applications or fixed installations of any size
AV, and theme parks
LYON, and LEOPARD systems
900-lfc accessories
MG-LEOPARD/900 Multipurpose Grid Flies
LEOPARDs, 900-LFCs, and mixed arrays. Also supports
LEOPARD and 900-LFC groundstack configurations.
PBF-LEOPARD Pull-Back Frame Provides pull-back
for extreme downtilt of flown LEOPARD and 900-LFC arrays,
and allows additional downtilt in groundstacked arrays.
Callisto 616 Array Processor Drives and aligns
Meyer Sound array systems with 6 x 16 matrix processing, delay integration, and EQ, using Compass software.
MVP Motor Vee Plate Attaches to MG-LEOPARD/900
grid and fine tunes horizontal aim of LEOPARD and
900‑LFC arrays.
MCF-900 Caster Frame Safely transports up to two
900-LFCs, making it easy to assemble and disassemble arrays
in blocks of two cabinets.
MDM-5000 Distribution Module Integrates
routing of audio, power, and RMS to loudspeaker arrays.
900-lfc specifications
Acoustical1
Operating Frequency Range2
Phase Response
31 Hz – 125 Hz
40 Hz – 110 Hz ±30 degrees
Transducer
Low Frequency
One 18-inch dual-coil, long-excursion cone driver
Audio I/O
Connectors3
XLR 3-pin or 5-pin female input with male loop output
Amplifier
Type
2-channel, open-loop, class D
AC Power
Connectors
Safety Rated Voltage Range
Turn-on/off Points
Max. Long-Term Cont. Current
powerCON 20 input with loop output
100–240 V AC, 50–60 Hz
90 V AC turn-on, no turn-off; internal fuse-protection above 265 V AC
4.9 A rms (115 V AC); 2.5 A rms (230 V AC); 5.2 A rms (100 V AC)
RMS Network
Equipped with 2‑conductor, twisted‑pair network, reporting
all amplifier operating parameters to host computer
Physical
Dimensions
Dimensions w/Rigging
Weight
Weight w/Rigging
Enclosure
27.47
Protective
Grille
[698
mm]
Rigging
24.47
[622 mm]
Load Ratings
27.43 in W x 24.43 in H x 24.89 in D (697 mm x 621 mm x 632 mm)
27.47 in W x 24.43 in H x 24.89 in D (698 mm x 621 mm x 632 mm)
136 lbs (61.7 kg)
159 lbs (72.1 kg)
Multi-ply hardwood with black textured finish
Hex-stamped steel with acoustical black mesh
Endframes with captive GuideALinks (0 to 5-degree splay angles), quick-release pins, and detachable
side handles
24.89
MG-LEOPARD/900 multipurpose
[632 mm]grid flies 16 900-LFCs (5:1 safety factor) or 11 900-LFCs (7:1 safety factor), with some restrictions
Notes
1 Loudspeaker system predictions
for coverage and SPL available in
Meyer Sound’s MAPP software.
2 Recommended maximum operating
frequency range. Response depends on
loading conditions and room acoustics.
3 XLR 5-pin connectors accommodate both
balanced audio and RMS signals.
900-LFC — 04.246.004.02 C3
Copyright © 2015, 2016
Meyer Sound Laboratories Inc.
All rights reserved
meyer sound laboratories inc.
2832 San Pablo Avenue
Berkeley, CA 94702
+1 510 486.1166
techsupport@meyersound.com
www.meyersound.com
24.43
[621 mm]
12.82
[326 mm]
27.47
[698 mm]
13.33
[339 mm]
24.47
[622 mm]
24.89
[632 mm]
24.43
[621 mm]
Ø1.50 [Ø38 mm] U.S.
Ø1.38 [Ø35 mm] E.U.
12.82
[326 mm]
13.33
[339 mm]
27.47
[698 mm]
architect specifications
24.47
[622 mm]
The loudspeaker shall be a compact, self-powered,
linear, low-distortion, low-frequency control element
and shall be capable of flown, groundstacked, and
cardioid configurations. Its transducer shall be one
18-inch dual-coil, long-excursion cone driver.
The loudspeaker shall incorporate internal
processing and a 2-channel, open-loop, class D
amplifier. Processing shall include equalization,
phase correction, and driver protection. Performance
specifications for a typical production unit shall
be as follows, measured at 1/3-octave resolution:
operating frequency range, 31 Hz to 125 Hz; phase
response, 40 Hz – 110 Hz ±30 degrees.
Audio connectors shall be XLR 3-pin, female and
24.89
[632 mm]
male, accommodating balanced audio, or XLR 5-pin, with a black textured finish. Optional rigging for
the enclosure shall include endframes with captive
accommodating both balanced audio and RMS.
Ø1.50 [Ø38 mm] U.S.
GuideALinks for linking units in vertical arrays at splay
Ø1.38 [Ø35 mm] E.U.
The internal power supply shall perform EMI filtering, angles from 0 to 5 degrees. The front protective grille
soft current turn-on,
and surge suppression. Power shall be powder-coated, hex-stamped steel with
24.43
mm]
requirements shall[621
be nominal
100, 110, or 230 V AC black mesh.
line current at 50–60 Hz. UL and CE operating
12.82
shall be 27.43 inches wide x
voltage range shall be 100–240 V AC at 50–60 Hz. Dimensions
[326 mm]
AC power connectors for input and loop output shall 24.43 inches high x 24.89 inches deep (697 mm x
be powerCON 20. Maximum long-term continuous 621 mm x 632 mm). Dimensions with optional rigging
current draw shall be 4.9 A rms at 115 V AC, 2.5 A rms at shall be 27.47 inches wide x 24.43 inches high x
24.89 inches deep (698 mm x 621 mm x 632 mm).
230 V AC, and 5.2 A rms at 100 V AC. The loudspeaker13.33
[339 mm]
Weight shall be 136 lbs (61.7 kg). Weight with optional
shall include an RMS remote monitoring system module.
rigging shall be 159 lbs (72.1 kg).
Components shall be mounted in an optimally tuned,
vented enclosure constructed of multi-ply hardwood The loudspeaker shall be the Meyer Sound 900-LFC.
Ø1.50 [Ø38 mm] U.S.
PRELIMINARY PRODUCT INFORMATION
CINE-STUDIO
Amie-SUB Compact Cinema Subwoofer
The Amie-Sub compact subwoofer is the
perfect complement for Amie Precision Studio
monitor. The linear, self-powered Amie-Sub
offers outstanding sonic characteristics such
as clean, punchy transients and excellent phase
coherence with impressive low-frequencies
down to 25 Hz in a compact cabinet. The AmieSub can be installed in stereo systems and has
ample headroom to be used in multichannel
LCR, 5.1, and 7.1 systems.
The Amie-Sub includes a single 15-inch lowfrequency, long-excursion cone driver. The
driver is housed in an optimally tuned, vented
cabinet and powered by a single-channel
amplifier. The cabinet’s shape provides easy
access to all connectors while being placed
directly in front of a wall. On-board processing
includes driver protection circuitry, low-pass
filtering, and correction filters for phase and
frequency responses.
The Amie-Sub has been optimized for use
with Amie but can also be used with other
Meyer Sound cinema loudspeakers, including
Acheron Designer screen channel loudspeakers
and the HMS-5, HMS-10, and HMS-12
surround loudspeakers in immersive surround
applications.
low-gloss, black-textured finish. A protective
hex-stamped grille is standard and an optional
grille frame with black cloth is available.
The Amie-Sub cabinet is constructed of
premium birch plywood and coated with a
Options include the MUB-Amie-Sub U-bracket
for mounting the subwoofer from ceilings.
solutions
features & benefits
peak power output with excellent
°° High
transient reproduction
amplitude and phase responses for
°° Flat
tonal accuracy
low frequency range down to
°° Extended
25 Hz
with Amie and Acheron
°° Integrates
Designer screen channel loudspeakers
low distortion for exceptional
°° Extremely
low-frequency clarity
with HMS-5, HMS-10 and
°° Integrates
HMS-12 surround loudspeakers
°° Small- to medium-sized editing rooms
and surround mixing for film and
°° Stereo
video postproduction
°° Broadcast monitoring
preliminary specifications
Notes
Acoustical
Operating Frequency Range1
Frequency Response2
Phase Response
Transducer
22 Hz – 160 Hz
25 Hz – 145 Hz ±4 dB
33 Hz – 145 Hz ±30 degrees
Low Frequency
Audio Input
One 15-inch long-excursion cone driver
Connectors
Input Impedance
Nominal Input Sensitivity
Amplifier
XLR 3-pin female input with XLR 3-pin male loop output
10 kΩ differential between pins 2 and 3
6.0 dBV (2.0 V rms) continuous average is typically the onset of limiting
for noise and music
Type
Load
Cooling
AC Power
Single channel
3 ohms
Convection
Connectors
Voltage Selection
Safety Rated Voltage Range
Physical
powerCON 20 inlet (with loop outlet to feed Amie loudspeakers)
Automatic, continuous range from 90 V AC to 265 V AC
100–240 V AC, 50–60 Hz
Dimensions
Weight
Enclosure
Mounting
1. Recommended maximum operating
frequency range. Response depends on
loading conditions and room acoustics.
2. Free field, measured with 1/3-octave
frequency resolution at 4 meters.
Amie-Sub
04.251.004.01 A
Copyright © 2016
Meyer Sound Laboratories Inc.
All rights reserved
meyer sound laboratories inc.
2832 San Pablo Avenue
Berkeley, CA 94702
+1 510 486.1166
24.00 inches W x 17.5 inches H x 19.00 inches D
(609 mm x 444 mm x 482 mm)
74 lbs (33.5 kg)
Premium birch plywood with low-gloss, textured black finish
Side nut-plates with 3/8” threads for optional MUB-Amie-Sub U-bracket
techsupport@meyersound.com
www.meyersound.com
DATASHEET
LF
MM-10™ Miniature Subwoofer
The MM‑10 miniature subwoofer delivers
expanded low frequency for applications
that require excellent audio quality from
a compact system. Designed primarily as
a companion to Meyer Sound's MM‑4XP
miniature loudspeaker, as well as the
UP‑4XP ultracompact loudspeaker, both with
IntelligentDC technology, the MM‑10 allows
system designers to create full-range systems
where space limitations are a concern.
The MM‑10 features an operating frequency
range of 33 Hz to 228 Hz with a conservatively
rated maximum peak SPL of 123 dB. The
MM‑10 bass reflex cabinet houses a single
10-inch driver and a single-channel power
amplifier complete with onboard processing,
including a crossover, driver protection, and
frequency and phase correction. The builtin crossover accepts full-range signals,
facilitating basic daisy-chaining for signal
distribution, eliminating the need for external
crossovers in small setups.
The MM‑10 subwoofer is available from the
factory in three models — the MM‑10XP,
with IntelligentDC technology, MM‑10AC,
and MM‑10ACX — each offering different
internal configurations and audio and power
connectors (which cannot be upgraded).
The MM‑10XP model is powered by an
external power supply, eliminating the need
for wiring conduits while still preserving the
advantages of self-powered loudspeaker
systems. The unit's onboard amplifier and
signal-processing circuits were designed to
store DC power and tolerate voltage drops,
thereby accommodating light-gauge cables
and lengthy cable runs. The MM‑10XP is
available with either a Phoenix™ 5-pin male
or sealed SwitchCraft® EN3™ male connector
for receiving balanced audio and DC power.
The EN3 connector is ideal for outdoor, allweather use.
MM‑10XPs require an external MPS‑488HP
IntelligentDC power supply. The single-space
19-inch rack unit receives balanced audio
from its XLR female inputs and routes the
audio, along with DC power, to its channel
outputs. The channel outputs — equipped
with either Phoenix 5-pin male connectors or
EN3 5-pin female connectors — can deliver
DC power to up to eight MM‑10XP subwoofers
at cable lengths of up to 150 feet with just
1 dB of loss in peak SPL using 18 AWG wire.
The use of composite multiconductor cables
(such as Belden® 1502) allows a single cable
to carry both DC power and balanced audio
to the MM‑10XPs. Longer cable runs are
possible for moderate applications that don't
drive the subwoofers to maximum output, or
for installations with heavier wire gauges.
The MM‑10AC model is ideal for fixed
installations and portable applications where
The MM‑10ACX model includes onboard DC
power and audio routing for driving a pair
of MM‑4XP miniature loudspeakers, or a
single UP‑4XP ultracompact loudspeaker,
effectively placing the MM‑10ACX at the heart
of an extremely capable compact, full-range
loudspeaker system. Three XLR female inputs
are included for receiving audio independitely
for the subwoofer and satellite loudspeakers.
The two output connectors for the satellite
loudspeakers are available with Phoenix
5-Pin male or EN3 5-pin female connectors. In
addition, a two-channel signal can be patched
to the satellite inputs and summed and routed
to the subwoofer with the input select switch.
Other options for all MM‑10 models include
the MUB‑MM10 U-bracket for mounting the
subwoofer on ceilings and walls; weather
protection, complete with rain hoods, for
outdoor, all-weather use; and custom color
finishes for installations and applications with
specific cosmetic requirements.
solutions
features & benefits
°° Powerful low-frequency response from a
to complement MM‑4XP and
°° Adaptable
UP‑4XP loudspeakers
distortion affords exceptionally clean
°° Low
bass
include external IntelligentDC
°° Versions
power supply or built-in AC power for
very small cabinet
AC power is readily available to power the
unit. The MM‑10AC includes an internal power
supply and locking powerCon® 20 connectors
for AC input and AC loop output (for powering
additional MM‑10AC subwoofers). The
MM‑10AC receives audio from an XLR female
input, and also includes an XLR male loop
output for daisy-chaining audio signals.
driving satellite loudspeakers
°° Background music
°° Small theatres
°° Portable AV systems
°° Compact voice reinforcement systems
MM-10 architect specifications (all models)
The loudspeaker shall be a self-powered, sub-bass system
with one 10-inch cone driver (with a 2-inch voice coil) rated
to handle 400 watts. The loudspeaker shall incorporate internal
processing electronics and a single-channel class D amplifier.
Processing functions shall include equalization, phase
correction, signal division, and driver protection. Amplifier
output power shall be 220 W (440 W peak). Distortion
(THD, IM, TIM) shall not exceed 0.02%.
Performance specifications for a typical production unit shall
be as follows, measured at 1/3-octave resolution: operating
frequency range, 33 Hz to 228 Hz; phase response, ±45°
from 38 Hz to 138 Hz; maximum peak SPL, 123 dB at 1 meter,
measured free field. Coverage shall be 360 degrees.
Loudspeaker components shall be mounted in a cabinet
constructed of multi-ply hardwood with a black textured finish.
Its front protective grille shall be hex-stamped steel with black
mesh screen.
The loudspeakers shall be the Meyer Sound MM‑10XP,
MM‑10AC, or MM‑10ACX.
MM-10XP
MM-10XP Rear Panel, EN3 Connector
Loudspeaker Input,
IntelligentDC power
and Balanced Audio
(Phoenix Connector
also Available)
Subwoofer
Polarity Switch
The loudspeaker shall be equipped with either a Phoenix 5-pin
male or EN3 5-pin male connector (three pins for balanced
audio and two pins for DC power). The audio input shall be
electronically balanced with a 10-kOhm impedance and accept
a nominal –2.0 dBV (0.8 V rms, 1.1 V peak) input signal. DC
blocking and RF filtering shall be provided, and CMRR shall be
greater than 50 dB and typically 80 dB (50 Hz to 500 Hz).
Power requirements for the loudspeaker shall be an external
Meyer Sound MPS-488HP IntelligentDC power supply capable
of delivering 48 V DC. Current draw during burst (< 1 sec) shall
be 2.5 A rms at 48 V DC; current inrush during turn-on shall not
exceed 7.0 A peak at 48 V DC.
Dimensions shall be 19 inches wide x 11 inches high x 12 inches
deep (482 mm x 279 mm x 305 mm). Weight shall be 26.7 lbs
(12.11 kg).
The loudspeaker shall be the Meyer Sound MM‑10XP.
MM-10AC
MM-10AC Rear Panel
The audio input shall be electronically balanced with a 10-kOhm
impedance and accept a nominal –2.0 dBV (0.8 V rms, 1.1 V
peak) input signal. Connectors shall be XLR female for input and
XLR male for loop output. DC blocking and RF filtering shall be
provided, and CMRR shall be greater than 50 dB and typically
80 dB (50 Hz to 500 Hz).
Subwoofer
Polarity Switch
Audio Input and
Loop Output
Power requirements shall be nominal 100 V, 110 V, or 230 V
AC line current at 50–60 Hz. UL and CE operating voltage
ranges shall be 100 to 240 V AC. AC power connectors shall be
powerCon 20 with looping output. Current draw during burst
(< 1 sec) shall be 0.9 A rms at 115 V, 0.4 A rms at 230 V AC, and
1.1 A peak at 100 V AC; current inrush during turn-on shall not
exceed 4.0 A rms at 115 V AC, 2.4 A rms at 230 V AC, and 4.0 A
peak at 100 V AC.
Dimensions shall be 19 inches wide x 11 inches high x 12 inches
deep (482 mm x 279 mm x 305 mm). Weight shall be 28.2 lbs
(12.79 kg).
AC Input
AC Loop
Output
The loudspeaker shall be the Meyer Sound MM‑10AC.
MM-10ACX
MM-10ACX Rear Panel, Phoenix Connectors
Subwoofer Input
Select Switch and
Gain Knob
Satellite Outputs,
48 V DC Power and
Balanced Audio
(EN3 Connectors
also Available)
Subwoofer
Polarity Switch
Subwoofer
Audio Input
Satellite
Audio Inputs
AC Input
AC Loop
Output
The audio input shall be electronically balanced with a 10-kOhm
impedance and accept a nominal –2.0 dBV (0.8 V rms, 1.1 V
peak) input signal. Three XLR female input connectors shall
be provided, one for the subwoofer and two for satellite
loudspeakers. DC blocking and RF filtering shall be provided,
and CMRR shall be greater than 50 dB and typically 80 dB
(50 Hz to 500 Hz). Two output connectors shall be provided for
routing balanced audio and 48 V of DC power to the satellite
loudspeakers.
Satellite output connectors shall be either Phoenix 5-pin male
or EN3 5-pin female (three pins for balanced audio, two pins
for DC power). An input select switch shall determine whether
the subwoofer receives its source from the subwoofer input or
from the satellite inputs (summed). The subwoofer output shall
be adjusted with a gain control.
Power requirements shall be nominal 100 V, 110 V, or 230 V
AC line current at 50–60 Hz. UL and CE operating voltage
range shall be 100 to 240 V AC. AC power connectors shall be
powerCon 20 with looping output. Current draw during burst
(< 1 sec) shall be 1.1 A rms at 115 V, 0.6 A rms at 230 V AC, and
1.3 A peak at 100 V AC; current inrush during turn-on shall not
exceed 6.6 A rms at 115 V AC, 3.7 A rms at 230 V AC, and 7.2 A
peak at 100 V AC.
Dimensions shall be 19 inches wide x 11 inches high x 12 inches
deep (482 mm x 279 mm x 305 mm). Weight shall be 30.8 lbs
(13.97 kg).
The loudspeaker shall be the Meyer Sound MM-10ACX.
6.50
6.50
6.50
6.50
[165
[165
mm]
mm]
[165
[165mm]
mm]
5.00
5.00
5.00
5.00
[127
[127
mm]
mm]
[127
[127mm]
mm]
12.00
12.00
12.00
12.00
[305
[305
mm]
mm]
[305
[305mm]
mm]
19.00
19.00
19.00
19.00
[483
mm]
[483
mm]
[483
[483mm]
mm]
MM-10ACX with EN3 connectors shown
11.00
11.00
11.00
11.00
[279
[279
mm]
mm]
[279
[279mm]
mm]
Dimensions 19 inches W x 11 inches H x 12 inches D
(483 mm x 279 mm x 305 mm)
Weight MM-10XP: 26.7 lbs (12.11 kg)
MM-10AC: 28.2 lbs (12.79 kg)
MM-10ACX: 30.8 lbs (13.97 kg)
Enclosure Multi-ply hardwood
Finish Black textured
Protective Grille Hex-stamped steel with black
mesh screen
MM-10 rigging
Top and side nut plates
available with 3/8"
or M10 threads. The
MUB‑MM10 U-bracket
mounts the MM-10 on
walls and ceilings at
adjustable angles.
MM-10 specifications (all models)
Acoustical
Operating Frequency Range1
Frequency Response2
Phase Response
Maximum Peak SPL3
Dynamic Range
Notes
33 Hz – 228 Hz
35 Hz – 208 Hz ±4 dB
38 Hz – 138 Hz ±45 degrees
123 dB
< 100 dB
Coverage
360 degrees
Transducer
Type
Nominal Impedance
Voice Coil Size
Power Handling
10-inch cone driver
4 ohms
2 inches
400 W (AES) 4
Audio Input
Type
Maximum Common Mode Range
Input Impedance
DC Blocking
CMRR
RF Filter
Nominal Input Sensitivity
Input Level
Differential, electronically balanced
±5 V DC
10 kOhms electronically balanced
4.8 Hz high pass
< –60 dB, typically < –72 dB (200 Hz – 3 kHz)
Common mode: 616 kHz
Differential mode: 616 kHz
–2.0 dBV (0.8 V rms) continuous is typically the onset of limiting
for noise and music
Audio source must be capable of producing +16 dBV (6.3 V rms,
9.0 V peak) into 600 ohms to produce the maximum peak SPL
over the operating bandwidth of the loudspeaker
Amplifier
Type
Output Power5
Total Output
THD, IM, TIM
Load Capacity
Cooling
Class D
220 W
440 W peak
< .02%
4 ohms
Convection
1.
2.
3.
4.
5.
Recommended maximum operating frequency range. Response
depends on loading conditions
and room acoustics.
Free field, measured with 1/3octave frequency resolution at
4 meters.
Measured with music referred to
1 meter.
Power handling measured under
AES standards: transducer driven
continuously for two hours with a
band-limited noise signal having
a 6 dB peak-average ratio.
Amplifier wattage rating based
on the maximum unclipped burst
sine-wave rms voltage the
amplifier will produce into the
nominal load impedance: 30 V
rms (42 V peak) into 4 ohms.
MM-10XP specifications
Notes
MM-10XP Rear Panel
Audio/Power Connector
Wiring
Input Polarity Switch
LED
MM-10XP DC Power
Safety Agency Rated Operating Range6
Current Draw:
Idle Current
Max. Long-Term Continuous Current (>10 sec)
Burst Current (<1 sec)
Ultimate Short-Term Peak Current
Inrush Current
MPS-488HP IntelligentDC Power Supply Required
Phoenix 5-pin male or EN3 5-pin male
(two pins for DC power, three pins for balanced audio)
Pin 1: DC power negative (–)
Pin 2: DC power positive (+)
Pin 3: Balanced audio shield, chassis/earth
Pin 4: Balanced audio (–)
Pin 5: Balanced audio (+)
Reverses audio input polarity between pins 4 and 5
Displays loudspeaker status
48 V DC
0.16 A rms
0.90 A rms
2.5 A rms
3.0 A peak
< 7.0 A peak
For information and specifications for the Meyer Sound MPS-488HP
IntelligentDC external power supply, refer to its datasheet.
MM-10AC specifications
MM-10AC Rear Panel
Audio Connectors
Input Polarity Switch
AC Power Connectors
LED
6. Tolerates voltage drops up to 30%
with long cable runs.
7. Audio loop output only included on
the MM-10AC model.
8. No automatic turn-off voltages.
Voltages above 265 V AC are fuse
protected but may cause permanent
damage to the power supply. Voltages below 90 V AC may result in
intermittent operation.
9. Current draw values for a single
MM‑10AC. AC Loop output not used.
10. Input Select switch only included on
the MM-10ACX model.
11. Gain knob only included on the
MM-10ACX model.
12. Satellite loudspeaker connectors only
included on the MM-10ACX model.
13. No automatic turn-off voltages.
Voltages above 265 V AC are fuse
protected but may cause permanent
damage to the power supply. Voltages below 90 V AC may result in
intermittent operation.
14. Current draw values for one
MM‑10ACX with no satellite loudspeakers connected. AC Loop output
not used.
15. Current draw values for one
MM-10ACX with two MM-4XP
satellite loudspeakers connected. AC Loop output not used.
XLR female input with XLR male loop output7
Pin 1: Chassis/earth through 220 kOhms, 1000 pF, 15 V clamp network
to provide virtual ground lift at audio frequencies
Pin 2: Signal +
Pin 3: Signal –
Case: Earth ground and chassis
Reverses audio input polarity between pins 2 and 3
powerCon 20 with loop output
Displays loudspeaker status
MM-10AC AC Power
Voltage Selection
Safety Agency Rated Operating Range
Turn-on and Turn-off Points8
Current Draw:9
Idle Current
Max. Long-Term Continuous Current (>10 sec)
Burst Current (<1 sec)
Ultimate Short-Term Peak Current
Inrush Current
Automatic
100–240 V AC, 50–60 Hz
90–264 V AC, 50–60 Hz
0.13 A rms (115 V AC); 0.13 A rms (230 V AC); 0.14 A rms (100 V AC)
0.40 A rms (115 V AC); 0.25 A rms (230 V AC); 0.46 A rms (100 V AC)
0.9 A rms (115 V AC); 0.4 A rms (230 V AC); 1.1 A rms (100 V AC)
2.0 A peak (115 V AC); 1.4 A peak (230 V AC); 2.3 A peak (100 V AC)
4.0 A peak (115 V AC); 2.4 A peak (230 V AC); 4.0 A peak (100 V AC)
MM-10ACX specifications
MM-10ACX Rear Panel
Subwoofer Audio Connector
Input Polarity Switch
Input Select Switch10
Gain Knob11
AC Power Connectors
Satellite Loudspeaker Connectors12
LED
XLR female input
Pin 1: Chassis/earth through 220 kOhms, 1000 pF, 15 V clamp network
to provide virtual ground lift at audio frequencies
Pin 2: Signal +
Pin 3: Signal –
Case: Earth ground and chassis
Reverses audio input polarity between pins 2 and 3 (subwoofer only)
Determines whether the subwoofer receives it source signal from the
subwoofer input or satellite inputs (summed)
Adjusts the subwoofer signal from completely attenuated to +10 dB
powerCon 20 with loop output
Two XLR female inputs
Two Phoenix 5-pin male or EN3 5-pin female outputs
(two pins for DC power, three pins for balanced audio)
Displays loudspeaker status
MM-10ACX AC Power
Voltage Selection
Safety Agency Rated Operating Range
Turn-on and Turn-off Points13
Automatic
100–240 V AC, 50–60 Hz
90–264 V AC, 50–60 Hz
Current Draw (Subwoofer Only):14
Idle Current
Max. Long-Term Continuous Current (>10 sec)
Burst Current (<1 sec)
Ultimate Short-Term Peak Current
Inrush Current
0.21 A rms (115 V AC); 0.20 A rms (230 V AC); 0.23 A rms (100 V AC)
0.48 A rms (115 V AC); 0.31 A rms (230 V AC); 0.55 A rms (100 V AC)
1.1 A rms (115 V AC); 0.6 A rms (230 V AC); 1.3 A rms (100 V AC)
2.2 A peak (115 V AC); 1.6 A peak (230 V AC); 2.5 A peak (100 V AC)
6.6 A peak (115 V AC); 3.7 A peak (230 V AC); 7.2 A peak (100 V AC)
Current Draw (with Two MM-4XPs):15
Idle Current
Max. Long-Term Continuous Current (>10 sec)
Burst Current (<1 sec)
Ultimate Short-Term Peak Current
Inrush Current
0.32 A rms (115 V AC); 0.26 A rms (230 V AC); 0.36 A rms (100 V AC)
0.90 A rms (115 V AC); 0.51 A rms (230 V AC); 1.02 A rms (100 V AC)
2.5 A rms (115 V AC); 1.3 A rms (230 V AC); 3.0 A rms (100 V AC)
4.5 A peak (115 V AC); 2.8 A peak (230 V AC); 5.0 A peak (100 V AC)
7.6 A peak (115 V AC); 4.4 A peak (230 V AC); 8.4 A peak (100 V AC)
MM-10 — 04.199.004.02 D
Copyright © 2014, 2015
Meyer Sound Laboratories Inc.
All rights reserved
meyer sound laboratories inc.
2832 San Pablo Avenue
Berkeley, CA 94702
+1 510 486.1166
techsupport@meyersound.com
www.meyersound.com
Open as PDF
Similar pages