Southbend R24-3 - Electric Steamer - 3 Pan Capacity

Electric Counter
Convection Steamer
Auto Fill, Auto Drain
Job
Compartment Pan Capacity
Model
PanDepth
1”
2-1/2”
4”
6”
R24-3
6
3
2
1
R24-5
10
5
3
2
Electrically heated steam generator operating at 0 psi (0 kPa)
with field replaceable elements rated at:
 7.5 kW for Model R24-3
 15.0 kW for Model R24-5
The steam generator shall be equipped for operation on:
 208 VAC, 3 Phase, 50/60 Hz. *
 240 VAC, 3 Phase, 50/60 Hz. *
* UNIT SHALL BE FIELD CONVERTIBLE TO SINGLE PHASE
OPTIONAL ITEMS AT EXTRA COST:
(R24-3 shown on optional stand)
SPECIFICATIONS:
Shall be a Southbend model R24-3 (3 pan) or R24-5 (5 pan) counter
convection steamer with electric steam generator, c-CSA-us and NSF
certified. Unit shall be constructed of satin finish 304 stainless steel with
a one piece welded 316 stainless steel cooking chamber with coved
corners. The door shall have a removable inner liner of stainless steel
with full perimeter gasket seal, an outer liner of one-piece all welded
stainless steel, and a positive lock and seal mechanism. The steamer
shall have removable stainless steel pan supports, a stainless steel drip
trough integrally connected to the drain in order to collect condensate
when the door is opened and adjustable leveling feet.
The control housing shall be constructed of stainless steel with a full
access removable panel. The controls shall include an illuminated three
way power switch (On/Off/De-lime), a pilot ready light, a pilot cook light,
60 minute electric timer with audible alarm at the end of the cooking
cycle. Steam flow to the cooking chamber shall be interrupted when the
door is opened and shall be reactivated when door is closed. Standard
features include a de-liming port located at the rear of the unit for easy
access to allow cleaning of the generator tank, de-lime mode power
setting, automatic blowdown valve, solid state liquid level controls and
split water connections for simple hook up to a water treatment system.
The steamer is constructed so that it may be mounted flush to the
counter top or on 4” (102 mm) legs. The steamer may also be stacked
using a stacking kit. The steamer comes standard with Southbend’s
water treatment system, model 1190861 for a single steamer or model
1190862 for double stacked steamers.
Form R24 Rev 0 (February/2011)









220 VAC, 3 Phase, 50/60 Hz.
380 VAC, 3 phase, 50/60 Hz.
415 VAC, 3 phase, 50/60 Hz.
480 VAC, 3 phase, 50/60 Hz.
600 VAC, 3 phase, 50/60 Hz.
380/220 VAC, 3 Phase, 50/60 Hz 4 wire.
415/240 VAC, 3 Phase, 50/60 Hz 4 wire.
Increase 7.5 kW to 10 kW (R24-3 only)
Correctional package.
ACCESSORIES:






4” (102 mm) adjustable legs
Stacking kit
Interconnect plumbing for 2 units
18” stainless steel stand
28” stainless steel stand
34” stainless steel stand
www.yatesgd.com www.yatesgraphicdesign.com
Item#
OPERATION SHALL BE BY:
 R24-3
 R24-5
Model
Shipping Weight
R24-3
141 lbs. [64 kg]
Minimum Clearance
SIDES
0
R24-5
169 lbs. [77 kg]
BACK
0
R24-3
R24-5
R24-3
R24-5
Models: SERVICE CONNECTIONS
– ELECTRICAL CONNECTION: Rating to be as specified on data plate.
– COLD WATER: 3/8” (10 mm) O.D. tubing at 25-50 psi (170-345 kPa).
– DRAIN: 2” (51 mm) IPS piped to open floor drain. No solid connection.
– GENERATOR WATER: 3/8” (10 mm) O.D. tubing at 25-50 psi (170-345 kPa).
ELECTRICAL CHARACTERISTICS
Model
R24-3
R24-5
kW
208V
3 PH
21
1 PH
34
220V
3 PH
20
AMPS/PHASE
240V
1 PH
3 PH
31
18
380V
3 PH
12
415V
3 PH
11
480 V
3 PH
9
600V
3 PH
8
7.5 Standard
1 PH
36
10 Optional
48
28
46
26
42
24
16
14
12
10
15 Standard
72
42
69
39
63
36
23
21
18
15
WATER QUALITY STATEMENT
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a local water
treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Total dissolved solids .....................Less than 60 PPM
Total alkalinity . ...............................Less than 20 PPM
Silica................................................Less than 13 PPM
Chlorine . ........................................Less than 30 PPM
pH Factor .......................................7.0 - 8.5
Water which fails to meet these standards should be treated by installation of water conditioner.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY. THE
STEAMER COMES STANDARD WITH SOUTHBEND’S WATER TREATMENT SYSTEM, MODEL 1190861 FOR A SINGLE STEAMER
OR MODEL 1190862 FOR DOUBLE STACKED STEAMERS.
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com