RAIN MASTER TM EAGLE PLUS RAIN MASTER TM EAGLE PLUS

RAIN MASTER EAGLE PLUS
TM
User’s Guide
• Installation
• Setup
• Programming
• Operation
• Troubleshooting
RAIN MASTER EAGLE PLUS
TM
SU 08:20:15A WK1
VALID PGM:14
[MAIN]
ALARM
IRIGATION
RAIN MASTER TM EAGLE PLUS
Introduction
Thank you for choosing the Irritrol Rain Master Eagle Plus controller for your
landscape irrigation system. We at Irritrol take great pride in developing and
building the finest irrigation products in the world, and are confident that
your new Rain Master Eagle Plus will provide the control features, resource
management tools, ease of use and robust design for years of dependable
service.
Programming Features
• StationRunTimefrom1minuteto23hoursand59minutes,in1-minute
increments.
• Stationdelaysettingfrom1minuteto19minutesand59seconds.
• Cycleruntime,MaximumCycletime,andSoaktimeonaper-stationbasis
• Pumpactivationindependentofthemastervalveonaper-programbasis
• Programstackingorsingleprogramoperation
• Wateringdayroutineoptionsonaper-programbasisinclude:
14-Day,SkipDaysandOdd/Even-numbereddays.
• Definablewateringwindowfrom1minuteto24hours.
• Cycle-and-Soakorstandardruntimeprogrammingonaper-programbasis.
• Copyfunctionsforprogram-to-programandstationruntime.
• ProgrammableMasterValveandaPumpoutputcontrolcapabilities:
Automatic Watering Operations
• Evapotranspiration(ET)basedscheduling.
• Percentageadjustmentonaper-programbasistoallowanincreaseor
decreaseofallstationruntimeswithinthatprogramfrom0–300%
in1%increments.
• Calculatedstationruntimeexecutedtothenearestsecond.
• ProgrammableWaterOfftopostponeirrigationfrom1to9days.
• Automaticminimizationofthewaterwindowbydynamicallyscheduling
stationstartswhenotherstationsareintheSoakmode.
Evapotranspiration (ET) Features
• ETprocessingonaperprogrambasis.
• MultipleETsourcesasthebasisforitsETcalculations:
••HistoricalETdata
••ManuallyenteredETdata
••WeatherCenter IIweatherstation
••Internet(withiCentralcommunicationenabled).
ii
RAIN MASTER TM EAGLE PLUS
Control Module Features
• Non-volatilememoryretainsallcontrollersetupandprogramming
information during power outages or seasonal shutdowns.
• Areal-timeclockwithnon-volatilebackuptomaintainthecurrentdateand
time during power outages without the need of batteries.
• Automaticallymonitorsallcriticaloperatingvoltagesandresets
microprocessorduringpower“brown-out”orerrorconditions.
• Automaticelectronicfuseresetsautomatically-eliminatesfusesorcircuit
breakers.
• Automaticresumptionofwateringprogramsafterpoweroutagefromthe
point of interruption.
• Automaticallydetectsproblemsonalloutputandinputcircuits.
• Built-inself-testforinternalcircuitry.
• Robustsurgeprotectiononfieldoutputcircuits.
Input Monitoring Features
• Rainsensorready–acceptsrainsensororweatherstationinput.
• Connectivityandinputfortwoflow-sensingdevices.
• ProgrammableflowsensorpipesizesforstandardRainMasterflowsensors
andnon-standardpipesizes.
• Programmableflowmonitoringfor:
••Mainlineflowlimit
••Unscheduledflowlimit
••Single-stationflowlimit
••Sampledelay
••Measuredstationflow.
Two-Wire Decoder System Control Features
(Two-Wire Decoder System Models Only)
• Two-WireDecoderboardinstallsinplaceofstandardstationoutputboards
• FullyintegratedTwo-WireDecodercapabilities
• Providescontrolofupto100decodersforatotalof202fieldoutputs
• Autodetectionandconfigurationduringpower-up
• Decoderprogrammingandmonitoringcapabilitiesinclude:
••Decoderandstationnumberassociation
••Outputcurrent
••Stationshort/opencircuit
••Decoderpresencedetection.
iii
RAIN MASTER TM EAGLE PLUS
Table of Contents
v
Control Module Overview ..........................................................................2
v
Controller Interior Component Overview ...............................................4
v
Selecting the Controller Setup Options ...................................................6
w
SettingtheCurrentTimeandDate ..................................................................7
w
SettingaSecurityAccessCode ..........................................................................9
w
SettingtheProgramStackOption ..................................................................11
w
SettingtheStationDelayOption .................................................................. 12
w
SettingtheMasterValveOption .................................................................... 13
w
SettingtheRegionalOptions .......................................................................... 14
w
SettingtheOdd/EvenDayOption ................................................................. 15
w
SettingtheAudibleAlertOption ................................................................... 16
w
SettingtheTimedWater-OffMode ................................................................17
w
SettingtheWaterWindowDuration .............................................................18
v
Selecting the Program Setup Options ................................................. 19
w
SettingtheProgramTypeOption..................................................................20
w
SettingtheProgramOdd/EvenDaysOption .............................................21
w
SettingtheProgramMasterValve/PumpControlOptions .................. 22
w
SettingtheProgramWeatherOptions ........................................................ 23
v
Selecting the ET Setup Options ............................................................. 24
v
Selecting the Flow Sensor Setup and Operation Options ................ 25
w
SettingtheUsageOption ................................................................................. 26
w
SettingtheStandard/CustomSensorOptions ......................................... 26
w
SettingtheFlowLimitsOptions.....................................................................27
w
SettingtheDelayOption ..................................................................................28
w
SettingtheLearnedFlowOptions ................................................................28
w
ResettingtheFlowTotalizer.............................................................................29
v
Setting the Communications Options .................................................. 30
v
Two-Wire Decoder System Setup ............................................................31
w
ProgrammingtheDecoders .............................................................................31
w
Two-WireDecoderSystemSetup ...................................................................31
w
ProgrammingtheDecoders .............................................................................31
w
TestingtheTwo-WireDecoderSystem ........................................................ 33
w
SingleStationTest ............................................................................................... 33
w
FindDecodersTest .............................................................................................. 34
w
AllStationsTest .................................................................................................... 35
iv
RAIN MASTER TM EAGLE PLUS
v
Programming for Automatic Operation ..............................................36
w
CreatingaNewProgram ................................................................................. 36
w
SettingaTwo-WeekWateringSchedule .....................................................37
w
SettingaSkip-DayWateringSchedule .......................................................37
w
SettingProgramStartTimes .......................................................................... 38
w
AssigningtheStationRunTime.................................................................... 38
w
SettingaCycleandSoakStationRunTime .............................................. 39
v
Modifying a Program: ............................................................................. 41
w
AdjustingProgramPercentValue .................................................................42
w
DeletingaProgram ............................................................................................42
v
Copying a Program or Runtime .............................................................43
w
ToCopyaProgram ............................................................................................ 43
w
ToCopyaRunTime ........................................................................................... 44
v
Review Mode ........................................................................................... 45
w
Program Review ..................................................................................................45
w
AlarmReview........................................................................................................ 46
w
CommReview ..................................................................................................... 46
w
FlowReview ......................................................................................................... 46
w
Irrigation Review .................................................................................................47
w
ET Review ...............................................................................................................47
v
Manual Watering Operations ................................................................ 48
w
ManualStationOperation .............................................................................. 48
w
ManualProgramOperation ........................................................................... 49
w
ManualMulti-StationOperation .................................................................. 50
w
ManualTestFunctions........................................................................................51
v
Alarms Feature .........................................................................................52
w
AlarmCategories.................................................................................................52
w
FieldWireFaultDetection ................................................................................52
w
FlowDetection.....................................................................................................52
w
ClearingAlarms .................................................................................................. 53
w
AnalyzingAlarms ............................................................................................... 54
wGeneralAlarms ................................................................................................... 54
w
FlowSensorAlarms ....................................................................................... 56
w
RainSensororWeatherStationAlarms .................................................. 58
w
Two-WireDecoderSystemAlarms ........................................................... 59
v
Appendix A - General Specifications ....................................................62
v
Appendix B - Flow Sensor Specifications ............................................63
v
Appendix C - Error Code Reference Chart ...........................................64
v
Appendix D - FCC Rules-Electromagnetic Compatibility .................65
v
RAIN MASTER TM EAGLE PLUS
Control Module Overview
3
ALARM
IRIGATION
1
SU 08:20:15A WK1
VALID PGM:14
2
[MAIN]
4
5
6
7
1 - Large LCD Display
ThelargeformatLCDdisplaypresentsallsetup,programming,systemcontrol
andmonitoringfunctionsinaninteractivemenu-drivenformat.
Note: To conserve power, the LCD backlight dims automatically after five minutes of
inactivity. The backlight is restored automatically with any controller input.
TheHomescreenisdisplayedbydefaultwhenthecontrollerisinthestandby
mode to provide basic controller status information.
1
2
3
4
The top line of the Home screen provides the
current day (1), current time (2),andweek1or
week2ofthetwo-weekwateringschedule(3).
WhenequippedforiCentralcommunications,
an antenna symbol (4) with signal strength
indication bars will be shown.
The second line indicates the current number of
configuredautomaticprograms:Noneor1–8for
standardsystems,or1–16forTwo-Wiresystems.
WhenthecontrollerisintheWaterOffmode,
WATEROFF is displayed.
The bottom line of the Homescreenprovides:
Main menu access (5), the pending number of
alarms (6),anddisplaysequencearrow(s)(7).
6
7
5
2
ControlModuleOverview
RAIN MASTER TM EAGLE PLUS
2 - Screen Sequence Keys
screen sequence keys are associated with the
The NEXT and BACK
corresponding and arrow symbols when displayed. Pressing a sequence
keystepsforwardorbackwardthroughamultiple-screensequence.
3 - Irrigation and Alarm Monitors
TheIrrigationLEDmonitorilluminatestoindicatesystemwateringactivity.The
AlarmLEDmonitorilluminateswhenasystemAlarmorAlertisgenerated.The
AlarmmonitorLEDwillremainilluminateduntilclearedbytheuser.Anaudible
Alertoptioncanbeenabledthatwill“chirp”everysixsecondstoindicateoneor
moreAlarmandorAlertconditions.
4 - Selection Dial
The selection Dialisthemainuser-interfacecomponent,providingasingle
rotary/push-buttondialtoselectandinputallcontrollersetupandoperating
features.
5 - Direct Access Menu Keys
Directaccesstoeachprimarymenufunctionisprovidedbypressingthe
correspondingselectionkeyasfollows:
Key –SelectstheMAIN PROGRAMmenu.ProvidesprogramPROGRAM
relatedoptionsincluding:newprogramsetup,existingprogramreview,program
modification, deletion, and copy functions.
SETUP
Key –SelectstheMAIN SETUP menu. Provides access to all setup
optionmenusincluding:CONTROLLER operating options, FLOW monitor setup,
PROGRAMoperatingoptions,COMMsetup,ETsetup,andTWO-WIREsystem setup.
Key –SelectstheMANUALOPERATIONS menu enabling manual
MANUAL
controloperationsincluding:SINGLESTATIONandMULTI-STATION operation,
PROGRAMoperationandmultipleTESTfunctions.
Key–SelectstheREVIEW menu for quick access to all controller
REVIEW
PROGRAMdetails,historicaldatalogsforIRRIGATIONevents,ALARMevents,
FLOWresults,ETrates,iCentralcommunicationsandcontrollersoftwareversion.
Key – Returns directly to the HOME menu from any location within
HOME
the menu hierarchy.
Key – Terminates all automatic watering activity. When
6 - WATER OFF
selected,allcurrentautomaticcontrolleroperationshutsdownandremainsoff
until the WATEROFFmodeisreleased.TheWaterOffLEDmonitorilluminates
when the controller is in the WATEROFF mode.
7 - Pro Max Remote Control Receptacle – Provides easy access for connection
andremoteoperationwiththe(optional)ProMaxremotecontrolsystem.
ControlModuleOverview
3
RAIN MASTER TM EAGLE PLUS
Controller Interior Component Overview
5
2
Wall-mount
Enclosure
1
3
6
6
6
1
2
3
4
1
3
SPED Pedestal-mount Enclosure
4
InteriorControllerComponentOverview
Interior
Controller Component Overview
PSB Pedestal-mount Enclosure
RAIN MASTER TM EAGLE PLUS
1 - Master Valve/Pump/Sensor Module
1
This module provides connections for
allauxiliarycomponentsincluding:
pump(1),mastervalve(2),fieldcommon(3),twoflowsensors(3),aWeather
Weather
CenterII(5)orarain/freeze
sensor(6),anda24VACpowersource.
4
4
5
6
7
3
2
1
2 - Station Output Module
(standard configuration)
Each output module provides connec2
tionsforeightstationoutputs(1)and
2
twofieldcommons(2).Uptosixstation
output modules can be installed for a
totalof48stationoutputs.
1
3 - Main Power Connection
Terminalblock(wall-mountmodels)
orjunctionboxprovideconnectionsfor
for
Line,Neutral,andEquipmentGround
2
wiring.PedestalmodelsprovideOn/Off
switch and power outlet.
4
4 - Two-Wire Decoder Module (optional)
AsingleTwo-WireDecodermodule
replacesthe8-stationoutputboard(s)
2
and connects to the control module
viaatwo-wire,plug-incableassembly.
TheDecodermoduleprovidestwo
separatedecodercontrolwirepairs(1)
andaquick-disconnectterminalblock
tofacilitatedecoderprogramming(2).
5 - iCentral with GSM Communications
Modem (optional)
TheiCentralmodemmountsonthe
back of the control module to provide
wireless communications capability
1
1
withtheiCentralcontrolsystem.
6 - iCentral Antenna (optional)
Externalantenna(optional)providesunitygainand200wattpower-handling
capacityforloing-rangecommunication.(Pedestalantennalocationindicated
butnotshowninillustration.)
ControllerInternalComponentOverview
5
RAIN MASTER TM EAGLE PLUS
Selecting the Controller Setup Options
The controller setup options determine how the controller displays and manages
the various tasks required to control and monitor your irrigation system.
Asetofdefaultcontrollersetupandoperatingoptionsisestablishedoninitial
power-up.Thetablebelowliststhevariouscontrollersetupmenuitems,the
available options and the factory default settings.
Setup Menu
Current Time
Current Date
Clock Format
Access Code
Program Stacking
Stacking Limits
Station Delay
Master Valve Config.
Units Format
Date Format
Odd/Even Days Off
Rain Days Off
Water Window
Audible Alarm
Option
Numeric Value, AM/PM
Alpha/Numeric
12- or 24-Hour
4-Digit Numeric
Yes or No
1 to 8 Programs
0–19 min, 0–59 sec
NC or NO
U.S. Standard or Metric
mm/dd/yy or dd/mm/yy
Yes or No
1–9 or None
0–24 Hours
On or Off
Default
12:00:00 a.m.
Thursday, 01/ 01/2009
12-Hour
0000
Yes
3 Programs
0 min, 0 sec
NC (normally closed)
U.S. Standard
mm/dd/yy
No
None
24 (12:00 a.m.–11:59 p.m.)
Off
Note: Synchronizing the controller with the current date and time should be
accomplished first. The remaining settings can be changed at any time. Some of the
settings will influence corresponding programming and controller operations. These
features are explained in detail within the applicable section of the User’s Guide.
Uponinitialpower-upandafterthecontrollerhasbeenwithoutpowerforan
extendedperiodoftime,theSETUPDATE/TIMEscreenisdisplayedbydefault.
Entertheactualtimeanddateperthefollowingstep-by-stepprocedure.When
you have completed this initial procedure, you will be familiar with the Eagle Plus
menu structure and how the multifunctional Dial allows you to easily navigate to
select,change,adjustandenterthevariouscontrollerprogrammingandsetup
options.
IMPORTANT: All setup and programming selections must be entered
(saved to memory) by pressing the Dial before pressing any of the Direct
Access keys. The controller will disregard any selection that has not been
saved.
Note: An audible “chirp” tone is generated each time a valid Key or Dial entry is made.
An invalid action is indicated by the chirp tone four times in rapid succession.
6
SettingtheCurrentTimeandDate
RAIN MASTER TM EAGLE PLUS
Setting the Current Time and Date
Note: Menu items displayed between dashes can be selected. Turn the Dial in either
direction to choose (bracket) the menu item, then press the Dial to select.
1. ThecontrollerwilldisplaytheSETUPDATE/TIME
DATE/TIME SETUP DATE/TIME:
screen upon initial power up.
DATE:[01/01/09]
TIME:-12:00AMFORMAT:-12 HOUR2. PresstheSETUP
menu.
key to display the SETUP
SETUP:
[CONTROLLER] –FLOW–
–PROGRAM–
–COMM–
–ET–
–TWO–WIRE–
4. PresstheDial toselecttheCONTROLLERmenu. SETUP CONTROLLER:
[DATE/TIME] –ACCESS–
TheDATE/TIMEoptionischosenbydefault.
–STACK–
–DELAY–
–MVALVE–
–MORE–
5. PresstheDial to select and display the SETUP
DATE/TIME screen. The DATE option is chosen
by default.
Note: In this procedure example, the date and
time will be changed from the default settings to
June 15, 2011, 2:45.
6. PresstheDial – theMonthdigits(01)willbegin
flashing.
7. Turn the Dial to display the current month
(06=June),thenpresstheDial to enter the
change.TheDaydigits(01)willbeginflashing.
SETUP DATE/TIME:
DATE:[01/01/09]
/01/09]
TIME:-12:00AMFORMAT:-12 HOUR-
SETUP DATE/TIME:
DATE:[01/01/09]
01/01/09]
TIME:-12:00AMFORMAT:-12 HOURSETUP DATE/TIME:
DATE:[06/01/09]
/01/09]
TIME:-12:00AMFORMAT:-12 HOUR-
8. TurntheDial to display the current day
(15),thenpresstheDial to enter the change.
TheYeardigits(09)willbeginflashing.
SETUP DATE/TIME:
DATE:[06/15/09]
09]
TIME:-12:00AMFORMAT:-12 HOUR-
9. TurntheDialtodisplaythecurrentyear(11),
then press the Dial to enter the change.
SETUP DATE/TIME:
E:
DATE:[06/15/11]
]
TIME:-12:00AMFORMAT:-12 HOUR-
SettingtheCurrentTimeandDate
7
RAIN MASTER TM EAGLE PLUS
10.TurntheDial right one step to choose
Time, then press the Dial to select. The
currenthourdigitswillbeginflashing.
SETUP DATE/TIME:
DATE:-06/15/11TIME:[12:00AM]
FORMAT:–12 HOUR–
11.TurntheDial to display the current hour
(02:),thenpresstheDial to enter the change.
Theminutesdigitswillbeginflashing.
SETUP DATE/TIME:
DATE:-06/15/11TIME:[02:00AM]
FORMAT:–12 HOUR–
12.TurntheDialtodisplaythecurrentminute(:45),
(:45), SETUP DATE/TIME:
DATE:-06/15/1115/11then press the Dial to enter the change. The
TIME:[02:45AM]
AMdesignatorwillbeginflashing.
FORMAT:–12 HOUR–
13.TurntheDial to display PM, then press the
Dial to enter the change.
SETUP DATE/TIME:
DATE:-06/15/11TIME:[02:45PM]
FORMAT:–12 HOUR–
14.PresstheHOME
keytoexittheSETUP menu.
Note: The initial Alarms shown on the Home screen are generated by default
during the power-up process and not indicative of a problem. Clear the Alarms as
follows:
•TurntheDial right one step to choose ALARMS.. TH 02:45:39P WK1
VALID PGM:NONE
•PresstheDial to select ALARMS.
•Thecauseofthealarmwillbedisplayed.
-MAIN- [ALARMS( 1)]
Press the Dial as needed to clear the alarms.
TH 02:45:39P WK1
POWER RESTORED
[CLEAR]
8
SettingtheCurrentTimeandDate
RAIN MASTER TM EAGLE PLUS
Setting a Security Access Code
This feature enables the user to establish an access code that must be entered to
gain access to various controller functions.
Theaccesscodecanbeanyfour-digitnumberbetween0001and9999.Afterthe
code has been established, a security level is applied that determines which of
the controller functions can remain accessible without entering the code.
• All–Disablesaccesscoderequirement–enablesunrestrictedcontrolleruse.
• Restricted–RequiresaccesscodetounlockProgramandSetupfunctions.
Manual,ReviewandWaterOfffunctionsremainunrestricted.
• No Access – Requires access code to unlock all controller functions.
key to display the SETUP
1. PresstheSETUP
menu. The CONTROLLER option is chosen by
default. Press the DialtoselectCONTROLLER.
SETUP:
[CONTROLLER] –FLOW–PROGRAM–
–COMM–
–ET–
–TWO–WIRE–
TheSETUPCONTROLLERmenuisdisplayed
SETUP CONTROLLER:
withtheDATE/TIMEoptionchosenbydefault. [DATE/TIME] –ACCESS–
–STACK–
–DELAY–
–MVALVE–
–MORE–
2. TurntheDial right one step to choose the
ACCESSoption.
SETUP CONTROLLER:
-DATE/TIME- [ACCESS]
–STACK–
–DELAY–
–MVALVE–
–MORE–
3. PresstheDial to select and display the
SETUPACCESS screen.
SETUP ACCESS
ENTER EXISTING CODE:
[XXXX]
Note: Select an access code that’s easy to recall,
then keep a copy of it written down for reference
if needed. If you forget or misplace your code,
contact Technical Support at 1-800-777-1477.
4. PresstheDialtobegin.Fourzeroswillbe
SETUP ACCESS
displayedwiththefirstdigitflashing.Either
ENTER EXISTING CODE:
[0000
[0000]
turn the Dial to change this digit, or press the
Dialtoselectthenextdigitinsequence.Repeat
Repeat
for all four digits.
Note: All four digits of the access code must be
selected and saved to retain the code in memory.
Exiting this procedure before entering the last
digit restores the default or previous access code.
SETUP ACCESS
ENTER EXISTING CODE:
[0123]
0123]
SettingaSecurityAccessCode
9
RAIN MASTER TM EAGLE PLUS
5. Enteringthefourthaccesscodedigitprompts
thenextscreeninthe access setup sequence.
Turn the Dial to choose the LEVELoption, then
press the Dial to select.
6. TurntheDial to display the preferred security
level:RESTRICTED,NOACCESSor ALL,then
Press the Dial to enter the selection.
SETUP ACCESS
LEVEL[
ALL
NEW CODE–0123–
–CLEAR CODE–
]
SETUP ACCESS
LEVEL[RESTRICTED]
NEW CODE–0123–
–CLEAR CODE–
Note: Once the access code has been entered, the
!
ACCESS DENIED!
controller functions will remain accessible until
ENTER CODE:[XXXX]
TO CONTINUE.
midnight. The access code must be entered each
time once the restrictions have been applied to gain
controller access. If attempting to enter an incorrect
access code, the ACCESS DENIED screen will be displayed.
7. When finished, press the HOME
returntotheHOMEscreen.
key to
To Clear and Reset the Current Access Code:
1. StartingfromtheSETUPACCESSscreen
(shownatright),turntheDial to choose
CLEARCODE, then press the Dial to select.
SETUP ACCESS
LEVEL–RESTRICTED–
NEW CODE–0123–
[CLEAR CODE]
2. Asafetyscreenisprompted.TurntheDial to
choose the Yes option, then press the Dial to
delete the access code.
ARE YOU SURE YOU
WANT TO CLEAR THE
ACCESS CODE?
[YES] –NO–
3. Toresettheaccesscode,repeataccesscode
setupprocedure,beginningatstep4.
4. When finished, press the HOME
return to the HOME screen.
10
SettingaSecurityAccessCode
key to
SETUP ACCESS
LEVEL[RESTRICTED]
NEW CODE[XXXX]
–CLEAR CODE–
RAIN MASTER TM EAGLE PLUS
Setting the Program Stack Option
This controller setup option enables you to specify whether multiple irrigation
programscanrunsimultaneously,ormustbe“stacked”orconstrainedtorunone
at a time in chronological order.
Bydefault,ProgramStackisaglobaloption,establishedforallprograms,but
canbedisabledforindividualprogramsaspreferred.TheProgramStackrange
isadjustablefrom1–8programs.WhentheStackoptionisdisabledforaspecific
program, that program is allowed to run simultaneously with other programs.
Caution: Before disabling the Stack option, it is very important to consider
the total current load and flow demand imposed on the system during
simultaneous multiple-program operations.
key to display the SETUP
1. PresstheSETUP
menu. The CONTROLLER menu item is chosen
by default. Press the Dial to select.
SETUP:
[CONTROLLER] –FLOW–PROGRAM–
–COMM–
–ET–
–TWO–WIRE–
2. TheSETUPCONTROLLERmenu is displayed.
SETUP CONTROLLER:
Turn the Dial right two steps to choose STACK. –DATE/TIME– –ACCESS–
[STACK]
–DELAY–
–MVALVE–
–MORE–
3. PresstheDial to display the SETUPPROGRAM
STACK screen. The Program option is chosen
by default. Press the Dial to select. The
programnumberwillbeginflashing.
SETUP PROGRAM STACK:
PROGRAM[ 1]
]
STACK-YESSTACKING LIMIT-1-
4. TurntheDial to display the preferred program
number(1–8forstandardsystems,or1–16for
two-wiredecodersystems).PresstheDial to
enter the number.
SETUP PROGRAM STACK:
PROGRAM[ 4]
]
STACK-YESSTACKING LIMIT-1-
5. TurntheDial right one step to choose the STACK
option, then press the Dial to select. The current
optionwillbeginflashing.TurntheDial to display
the preference, then press the Dial to enter.
Note: The Stacking Limit option is applicable
only with the Yes option selected.
6. TurntheDial right one step to choose
STAKINGLIMIT, then press the Dial to select.
Thecurrentnumberwillbeginflashing.Turn
the Dial to display the preferred number from
1–8,thenpresstheDial to enter the selection.
SETUP PROGRAM STACK:
PROGRAM– 4
4–
STACK[YES]
]
STACKING LIMIT-1-
7. When finished, press the HOME
SETUP PROGRAM STACK:
PROGRAM- 4STACK-YESSTACKING LIMIT[2]
]
key to return to the HOME screen.
SettingtheProgramStackOption
11
RAIN MASTER TM EAGLE PLUS
Setting the Station Delay Option
Irrigationsystemsthatutilizeapumpstationand/orslow-closingvalvesmay
require a delay or dwell time to occur between the station operating sequence.
TheStationDelayfeatureenablesyoutoenteradelayperiodfrom1secondto
19minutes.NotethattheStationDelayperiodisappliedgloballytoallstation
operating sequences.
key to display the SETUP
1. PresstheSETUP
menu. The CONTROLLER menu item is chosen
by default. Press the Dial to select.
SETUP:
[CONTROLLER] –FLOW–PROGRAM–
–COMM–
–ET–
–TWO–WIRE–
2. TheSETUPCONTROLLERmenu is displayed.
Turn the Dialright3stepstochooseDELAY.
SETUP CONTROLLER:
–DATE/TIME– –ACCESS–
-STACK[DELAY]
–MVALVE–
–MORE–
3. PresstheDial to display the SETUPSTATION
DELAY screen. The MINUTESoption is chosen
by default. If the preferred delay period is less
than1minute,turntheDial right one step to
choose Seconds.
4. PresstheDial to select. The current value
(0bydefault)willbeginflashing.
SETUP STATION DELAY:
MINUTES[ 0] (0-19)
SECONDS- 0- (0-59)
5. TurntheDial to display the SECONDS value.
Press the Dial to enter.
6. Whenfinished,presstheHOME
return to the HOME screen.
12
SettingtheStationDelayOption
key to
SETUP STATION DELAY:
MINUTES- 0- (0-19)
SECONDS[ 0]
] (0-59)
SETUP STATION DELAY:
MINUTES- 0- (0-19)
SECONDS[10] (0-59)
RAIN MASTER TM EAGLE PLUS
Setting the Master Valve Option
Whenamastervalveisutilizedintheirrigationsystemtocontrolthemain
linewatersupply,itisimperativethattheMasterValveconfigurationoption
correspondscorrectlytoeitheraNormallyOpenoraNormallyClosedvalve.The
defaultMasterValveconfigurationoptionisNormallyClosed.
Forexample,ifasystemflowlimitisexceeded,thecontrollerwillturnoffpower
tothemastervalve,causingittoclose,whenconfiguredforNormallyClosed
operation,WhenconfiguredforaNormallyOpenmastervalve,thecontrollerwill
apply constant power to the valve, causing it to remain closed.
key to display the SETUP
1. PresstheSETUP
menu. The CONTROLLER menu item is chosen
by default. Press the Dial to select.
SETUP:
[CONTROLLER] –FLOW–PROGRAM–
–COMM–
–ET–
–TWO–WIRE–
2. TheSETUPCONTROLLERmenu is displayed.
Turn the Dialright4stepstochooseMVALVE,
then press the Dial to select.
SETUP CONTROLLER:
-DATE/TIME- -ACCESS–STACK–
–DELAY–
[MVALVE]
–MORE–
3. TheSETUPMASTERVALVE screen is
displayed. The NORMALCLOSE option is
chosen by default. Press the Dial to select.
Theoptionwillbeginflashing.
SETUP MASTER VALVE:
TYPE[NORMAL CLOSE]
4. TurntheDial to display the NORMALOPEN
option, then press the Dial to enter.
5. Whenfinished,presstheHOME
return to the HOME screen.
SETUP MASTER VALVE:
TYPE[NORMAL OPEN ]
key to
SettingtheMasterValveOption
13
RAIN MASTER TM EAGLE PLUS
Setting the Regional Options
Regional options enable you to configure the display information for various
regionaloptionsincluding:unitsofmeasure,displaylanguageanddateformat.
The chart below provides the Regional options and the default settings.
Units
English
Metric
Language
- English (default)
- Spanish
- French
- German
- Italian
Date Format
MM/DD/YY
(month, day, year
- default)
DD/MM/YY
(day, month, year)
Note: Regional option availability differs for Domestic and International controller
models. Domestic models provide optional selection of the Date Format only.
key to display the SETUP
1. PresstheSETUP
menu. The CONTROLLER menu item is chosen
by default. Press the Dial to select.
2. TheSETUPCONTROLLERmenu is displayed.
Turn the Dialright5stepstochooseMORE,
then press the Dial to select.
key will also access
Note: Pressing the NEXT
the next screen in sequence (indicated by the
down arrow symbol).
3. TheSETUPMORE screen is displayed with the
REGION option chosen by default. Press the
Dial to select.
4. TheSETUPREGIONmenuscreenisdisplayed
withtheDATEFORMATchosenbydefault.
SETUP:
[CONTROLLER] –FLOW–PROGRAM–
–COMM–
–ET–
–TWO–WIRE–
SETUP CONTROLLER:
-DATE/TIME- -ACCESS–STACK–
–DELAY–
-MVALVE[MORE]
SETUP MORE:
[REGION] -ODD/EVEN–SOUND– -WATER OFF–
-WATER WINDOWSETUP REGION:
UNITS-ENGL. LANGUAGE-ENGLISHDATE FORMAT[MM/DD]
5. PresstheDialtoselect.TurntheDial to display SETUP REGION:
UNITS-METRICthe preferred option, then press the Dial to
LANGUAGE-ENGLISHenter the selection.
DATE FORMAT[MM/DD]
6. Whenfinished,presstheHOME
14
SettingtheRegionalOptions
key to return to the HOME screen.
RAIN MASTER TM EAGLE PLUS
Setting the Odd/Even Day Option
Bydefault,theOdd/Evencalendardayschedulingoptionisdisabled.Inorderto
utilizethiscontrolfeatureintheProgramSetupoptions,itmustfirstbeenabledinthe
ControllerSetupoptions.
Note: For additional information regarding the function and implementation of the
Odd/Even feature, refer to Program Setup Options on page 21.
1. PresstheSETUP
key to display the SETUP
menu. The CONTROLLER menu item is chosen
by default. Press the Dial to select.
2. TheSETUPCONTROLLERmenu is displayed.
Turn the Dialright5stepstochooseMORE,
then press the Dial to select.
SETUP:
[CONTROLLER] –FLOW–PROGRAM–
–COMM–
–ET–
–TWO–WIRE–
SETUP CONTROLLER:
-DATE/TIME- -ACCESS–STACK–
–DELAY–
-MVALVE[MORE]
key will also access
Note: Pressing the NEXT
the next screen in sequence (indicated by the down
arrow symbol).
3. TheSETUPMORE screen is displayed with the SETUP MORE:
–REGION– [ODD/EVEN]
REGION option chosen by default.
–SOUND– -WATER OFF–
Turn the Dial right one step to choose the
-WATER WINDOWODD/EVENoption,thenpresstheDialtoselect.
select.
5. TheSETUPODD/EVENscreenisdisplayedwith SETUP ODD/EVEN:
WATERING-NO chosen by default.
WATERING[NO ]
TYPE-ODD Note: For this option, it is preferable to set TYPE
first, and then set the WATERING - YES/NO option.
(See step 6 below.)
6. TurntheDial to choose TYPE, then press the
Dial to select. Turn the Dial to display EVEN or
ODD, then press the Dial to enter.
SETUP ODD/EVEN:
WATERING -NO TYPE[EVEN]
7. Turn the Dial left one step to choose WATERING, SETUP ODD/EVEN:
WATERING[YES]
then press the Dial to select. Turn the Dial to
TYPE[EVEN]
display YES, then press the Dial to select.
AWARNING screen will be displayed. Press
the DialtoselectOK,orturnDial to choose
CANCEL,thenpresstheDial to return to the
previous screen.
8. Whenfinished,presstheHOME
WARNING: YOU HAVE
ELECTED TO WATER ON
EVEN CALENDAR DAYS
ONLY. [OK] -CANCEL-
key to return to the HOME screen.
SettingtheOdd/EvenDayOption
15
RAIN MASTER TM EAGLE PLUS
Setting the Audible Alert Option
TheAudibleAlertoptionisOffbydefault.Whenenabled,anAlarmconditionwill
triggeranAlert“chirp”toneeverysixsecondsuntiltheAlarmconditioniscleared.
key to display the SETUP
1. PresstheSETUP
menu. The CONTROLLER menu item is chosen
by default. Press the Dial to select.
2. TheSETUPCONTROLLERmenu is displayed.
Turn the Dialright5stepstochooseMORE,
then press the Dial to select.
key will also access
Note: Pressing the NEXT
the next screen in sequence (indicated by the
down arrow symbol).
3. TheSETUPMORE screen is displayed with the
REGION option chosen by default. Turn the
Dial right two steps to choose SOUND,then
press the Dial to select.
4. TheSETUPSOUND screen is displayed with
theOFFoptionselectedbydefault.
SETUP:
[CONTROLLER] –FLOW–PROGRAM–
–COMM–
–ET–
–TWO–WIRE–
SETUP CONTROLLER:
-DATE/TIME- -ACCESS–STACK–
–DELAY–
-MVALVE[MORE]
SETUP MORE:
-REGION- -ODD/EVEN[SOUND] -WATER OFF–
-WATER WINDOW-
SETUP SOUND:
AUDIBLE ALARM[OFF]
5. PresstheDial to select, then turn the Dial
to display ON. Press the Dial to enter the
selection.
6. Whenfinished,presstheHOME
16
SettingtheAudibleAlertOption
key to return to the HOME screen.
RAIN MASTER TM EAGLE PLUS
Setting the Timed Water-Off Mode
ThisfeatureprovidesameansofplacingthecontrollerintheWaterOffmodefor
atimeddurationfrom1to9days.
Note: The Water Off mode can be terminated at any time by any one of the following
methods:
• Press the WATER OFF key.
• ResettheWaterOffdaydurationtoNONE.
• ChooseTURNWATERONfromtheMAINmenu,thenpresstheDial to select
TURNWATEROFF.
key to display the SETUP SETUP:
1. PresstheSETUP
menu. The CONTROLLER menu item is chosen [CONTROLLER] –FLOW–PROGRAM–
–COMM–
by default. Press the Dial to select.
–ET–
–TWO–WIRE–
2. TheSETUPCONTROLLERmenu is displayed.
Turn the Dialright5stepstochooseMORE,
then press the Dial to select.
key will also access
Note: Pressing the NEXT
the next screen in sequence (indicated by the
down arrow symbol).
3. TheSETUPMORE screen is displayed with the
REGION option chosen by default. Turn the
Dial right three steps to choose WATEROFF,
then press the Dial to select.
4. TheSETUPWATEROFFscreenisdisplayed.
Press the Dialtoselect[None],thenturnthe
Dialtodisplay1to9days.
SETUP CONTROLLER:
-DATE/TIME- -ACCESS–STACK–
–DELAY–
-MVALVE[MORE]
SETUP MORE:
-REGION- -ODD/EVEN-SOUND- [WATER OFF]
-WATER WINDOWSETUP WATER OFF:
NUMBER OF DAYS
CONTROLLER REMAINS
IN WATER OFF [ 4]
5. PresstheDial to enter. The controller will switch
to the WATEROFFmodeandtheLEDindicator
will illuminate.
Note: If a 1-day duration is selected, the WATER OFF mode will be automatically
released at the day change (Midnight).
6. Whenfinished,presstheHOME
key to return to the HOME screen.
SettingtheTimedWater-OffMode
17
RAIN MASTER TM EAGLE PLUS
Setting the Water Window Duration
Thisoptionenablesyoutodefineaspecificperiod(orwindow)oftimewithinthe
24-hourdaytocompleteallscheduledwateringactivity.Onceestablished,any
scheduled watering activity that would either start or continue running outside of
thewindowwillbeignored.Built-inprogrammingalertswillbedisplayedifawater
windowschedulingconflictoccurs.Bydefault,theWaterWindowsettingis24hours.
Note: When decreasing the Water Window, it is important to consider that an increase
in station run time through the use of the Percent Adjust and/or ET control features, can
extend program watering duration beyond the Water Window limit,resulting in an
Alarm condition.
key to display the SETUP
1. PresstheSETUP
menu. The CONTROLLER menu item is chosen
by default. Press the Dial to select.
2. TheSETUPCONTROLLERmenu is displayed.
Turn the Dialright5stepstochooseMORE,
then press the Dial to select.
key will also access
Note: Pressing the NEXT
the next screen in sequence (indicated by the
down arrow symbol).
3. TheSETUPMORE screen is displayed with the
REGION option chosen by default. Turn the
Dial right four steps to choose WATER
WINDOW,then press the Dial to select.
4. TheSETUPWATERWINDOW screen will be
displayed. Press the Dial to select START time.
Turn the Dial to display the preferred start time
hour, then press the Dial to enter. The minutes
digitswillbeginflashing.
5. TurntheDial to display the preferred start time
minutes. Press the Dialtoenter.TheAM/PM
indicatorwillbeginflashing(12-hourmode
only).TurntheDialtodisplaytheAM/PM
preference, then press the Dial to enter.
6. TurntheDial right one step to choose the
ENDtime.SettheEND time using the same
procedure as the START time.
7. When finished, press the HOME
return to the HOME screen.
18
SettingtheWaterWindowDuration
key to
SETUP:
[CONTROLLER] –FLOW–PROGRAM–
–COMM–
–ET–
–TWO–WIRE–
SETUP CONTROLLER:
-DATE/TIME- -ACCESS–STACK–
–DELAY–
-MVALVE[MORE]
SETUP MORE:
-REGION- -ODD/EVEN-SOUND- –WATER OFF–
[WATER WINDOW]
SETUP WATER WINDOW:
START[05:00AM]
END-11:59PM-
SETUP WATER WINDOW:
START[05:30AM]
END–11:59PM–
SETUP WATER WINDOW:
START-05:30PMEND[11:59PM]
RAIN MASTER TM EAGLE PLUS
Selecting the Program Setup Options
WithintheControllerSetupmenuoptions,theselectionsmadeapplied
universallytoallactiveprograms.WithintheProgramSetupoptions,operating
parameters specific to each program are established.
The table below lists the various available Program Setup options and the factory
default settings.
Setup Program Menu
Type
Option
Default
- Water Days: 14-Day/Skip Day 14-Day
- Irrigation/Non-Irrigation
Irrigation
- Cycle and Soak: Yes/No
No
Odd/Even Days
- Enabled/Disabled
Disabled
Weather
- ET: Enabled/Disabled
- Rain Sensor: Yes/No
Disabled
No
Program Type
•WaterDays–A14-dayscheduleisthedefaultoptionthatenablesindividual
daysofarecurrent,two-weekscheduletobeassigned.TheSkip-Dayoption
constrainsactivedaystoaspecifiedinterval,rangingfromeveryday(skip0
days),toonceevery31days(skip30days).
•Irrigation/Non-Irrigation– Programs can be defined for either irrigation control
ornon-irrigationcontrol;e.g.,outdoorlightingorfilterpumpsaspreferred.
•Cycle/Soak–TheCycleandSoakoptionenablesadelayperiodtobe
interspersedwiththestationruntimetohelpreducerunoffduetoalow
absorption rate or to prevent furrowing and seed loss during an initial turf
grow-inperiod.
Odd/Even Days
Whenenabled,eitherOdd-orEven-daywateringisspecified.Withinthe
individualProgramSetupoptions,thespecifiedoption(OddorEven)is
displayedwithaYES/NOoption.SelectingYESassignsthescheduletothe
program;selectingNO ignores the schedule.
Note: The Odd/Even day scheduling option must be enabled within the Controller
Setup options to be selectable within the Program Setup options.
Master Valve /Pump:
Thisoptionenables/disablesconcurrentoperationoftheMasterValve(MV)and/
orPumponaper-programbasis.Bydefault,bothMasterValveandPumpoutput
controlsareassignedtoallirrigationprogramsanddisabledforallnon-irrigation
programs.
SelectingtheProgramSetupOptions
19
RAIN MASTER TM EAGLE PLUS
Setting the Program Type Option
key to display the SETUP
1. PresstheSETUP
menu. The CONTROLLER menu item is chosen
by default. Press the Dial to select.
2. TurntheDial right two steps to choose
PROGRAM, then press the Dial to select.
SETUP:
[CONTROLLER] –FLOW–PROGRAM–
–COMM–
–ET–
–TWO–WIRE–
SETUP:
-CONTROLLER- -FLOW[PROGRAM]
–COMM–
–ET–
–TWO–WIRE–
3. TheSETUPPROGRAM menu screen is displayed SETUP PROGRAM:
with TYPE chosen by default.
[TYPE]
-ODD/EVEN-MV/PUMP- -ET SETUP
Press the Dial to select.
4. The nextSETUPPROGRAM screen in sequence
is displayed with the program number chosen
by default. Press the Dial to select. Turn the Dial
to display the preferred program number, then
press the Dial to enter.
5. TurntheDial right one step to choose the
WATERDAYS. The 14DAY option is displayed
by default. Press the Dial to select.
SETUP PROGRAM: - 2WATER DAYS[ 14 DAY ]
TYPE- IRRIGATION CYCLE/SOAK- NO-
6. TurntheDial to display SKIPDAYor14DAY
option as preferred, then press the Dial to enter
the selection.
SETUP PROGRAM: - 2WATER DAYS[SKIP DAY]
TYPE- IRRIGATION CYCLE/SOAK- NO-
7. Turn the Dial right one step to choose the
Program TYPE option, then press the Dial to
select.
SETUP PROGRAM: - 2WATER DAYS-SKIP DAYTYPE[ IRRIGATION ]
CYCLE/SOAK- NO-
8. TurntheDial to display NONIRRIGATION
(i.e.foroutdoorlighting)orIRRIGATION option,
then press the Dial to enter the selection.
SETUP PROGRAM: - 2WATER DAYS-SKIP DAYTYPE[NON-IRRIGATION]
CYCLE/SOAK- NO-
9. TurntheDial right one step to choose the
CYCLE/SOAK option.
10.TurntheDial to display the YES or NOoption,
then press the Dial to enter the selection.
11.Whenfinished,presstheHOME
to return to the HOME screen.
20
SettingtheProgramTypeOption
key
SETUP PROGRAM: [ 1]
WATER DAYS- 14 DAYTYPE- IRRIGATION CYCLE/SOAK- NO-
SETUP PROGRAM: - 2WATER DAYS-SKIP DAYTYPE- IRRIGATION CYCLE/SOAK[ NO]
SETUP PROGRAM: - 2WATER DAYS-SKIP DAYTYPE- IRRIGATION CYCLE/SOAK[YES]
-
RAIN MASTER TM EAGLE PLUS
Setting the Program Odd/Even Calendar Days Option
Note: To assign program(s) to an Odd or Even numbered calendar day schedule,
the Odd /Even schedule option must be established first within the Controller setup
parameters. Refer to page 15 for Controller Odd/Even setup procedures.
Note: Programs can only be assigned to an Odd OR Even schedule, as specified
within Controller setup parameters. In other words, one program can not be assigned
to an Even schedule and another program assigned to an Odd schedule.
Note: When the Odd/Even program option is enabled, watering will NOT occur on
the 31st day of the month or Leap Day (February 24).
key to display the SETUP
1. PresstheSETUP
menu. The CONTROLLER menu item is chosen
by default. Press the Dial to select.
2. TurntheDial right two steps to choose
PROGRAM, then press the Dial to select.
SETUP:
[CONTROLLER] –FLOW–PROGRAM–
–COMM–
–ET–
–TWO–WIRE–
SETUP:
-CONTROLLER- -FLOW[PROGRAM]
–COMM–
–ET–
–TWO–WIRE–
3. TheSETUPPROGRAM menu screen is displayed
SETUP PROGRAM:
with the TYPE option chosen by default. Turn
-TYPE[ODD/EVEN]
the DialrightonestoptochoosetheODD/EVEN -MV/PUMP- -ET SETUP
option, then press the Dial to select.
4. Theprogramnumberischosenbydefault.
Press the Dial to select, then turn the Dial to
display the preferred program number. Press
the Dial to enter the selection.
SETUP PROGRAM:[ 1]
ODD/EVEN:ENABLED
EVEN–YES
5. TurntheDial right one step to choose the
YES/NO option.BydefaulttheOddorEven
option is not selected for programs.
SETUP PROGRAM:- 1ODD/EVEN:ENABLED
EVEN[NO ]
6. ToassigntheEVEN day option to this program, SETUP PROGRAM:- 1press the Dial to select NO. The option will
ODD/EVEN:ENABLED
EVEN[NO ]
beginflashing.TurntheDial to display YES,
then press the Dial to enter the selection.
7. Repeat this procedure for each program number as required, beginning at
step4.
8. Whenfinished,presstheHOME
key to return to the HOME screen.
SettingtheProgramOdd/EvenDaysOption
21
RAIN MASTER TM EAGLE PLUS
Setting the Program Master Valve/Pump Control Options
Note: By default, the master valve and pump control options are enabled for all
programs. Disabling these functions may be required for non-irrigation programs.
See page 13 for Master Valve/Pump configuration and setup procedures.
key to display the SETUP
1. PresstheSETUP
menu. The CONTROLLER menu item is chosen
by default. Press the Dial to select.
2. TurntheDial right two steps to choose
PROGRAM, then press the Dial to select.
3. PresstheDial to display the SETUPPROGRAM
menu screen. TYPE is chosen by default.
4. TurntheDial right two steps to choose
MV/PUMP.
SETUP:
[CONTROLLER] –FLOW–PROGRAM–
–COMM–
–ET–
–TWO–WIRE–
SETUP:
-CONTROLLER- -FLOW[PROGRAM]
–COMM–
–ET–
–TWO–WIRE–
SETUP PROGRAM:
[TYPE]
-ODD/EVEN-MV/PUMP- -ET SETUP
SETUP PROGRAM:
-TYPE-ODD/EVEN[MV/PUMP] -ET SETUP-
5. PresstheDial to display the MASTERVALVE
and PUMP screen. The program number is
chosen by default.
SETUP PROGRAM:[ 1]
MASTER VALVE-YESPUMP-YES-
6. PresstheDial to select the program number.
Turn the Dial to display the preferred program
number, then press the Dial to enter.
SETUP PROGRAM:- 1MASTER VALVE[YES]
PUMP-YES-
7. Turn the Dial right one step to choose the
SETUP PROGRAM:- 1MASTERVALVE option. YES is selected by default. MASTER
VALVE[NO ]
To disable MASTERVALVE operation for this
PUMP-YESprogram, press the Dial to select, turn the Dial to
display NO, then press the Dial to select.
8. TurntheDial right one step to choose the
SETUP PROGRAM:- 1MASTER VALVE-NO PUMP option. YES is selected by default.
PUMP[NO ]
To disable PUMPoperation for this program,
turn the Dial to display NO, then press the Dial
to select.
9. Repeatthisprocedureforeachprogramaspreferred,beginningatstep5.
10.Whenfinished,presstheHOME
22
key to return to the HOME screen.
SettingtheProgramMasterValve/PumpControlOptions
RAIN MASTER TM EAGLE PLUS
Setting the Program Weather Options
TheoptionalET(Evapotranspiration)and/orRainSensorcontrolfeaturesare
disabledbydefaultforallprograms.Inordertoutilizeeitherofthesefeatures,
they must first be enabled within the Weather option screen.
Note: When ET is enabled for a program, a Percent Adjustment applied to that program
will be ignored. Refer to Modify Program options, page 41 for additional information.
key to display the SETUP
1. PresstheSETUP
menu. The CONTROLLER menu item is chosen
by default. Press the Dial to select.
2. TurntheDial right two steps to choose
PROGRAM, then press the Dial to select.
SETUP:
[CONTROLLER] –FLOW–PROGRAM–
–COMM–
–ET–
–TWO–WIRE–
SETUP:
-CONTROLLER- -FLOW[PROGRAM]
–COMM–
–ET–
–TWO–WIRE–
3. TurntheDial right two steps to choose the
WEATHER option. Press the Dial to display
the ET and RAINSENSOR option screen. The
program number is chosen by default.
4. PresstheDial to select. The program number
willbeginflashing.TurntheDial to display the
preferred program number, then press the
Dial to enter the selection.
5. TurntheDial right one step to choose the ET
option. DISABLED is selected by default.
SETUP PROGRAM:
-TYPE-ODD/EVEN-MV/PUMP- [WEATHER]
SETUP PROGRAM:[ 2]
ET-DISABLEDRAIN SENSOR- NO SETUP PROGRAM:- 2ET[DISABLED]
RAIN SENSOR- NO -
6. PresstheDial to select. Turn the Dial to display SETUP PROGRAM:- 2ET[ENABLED ]
the ENABLED option. Press the Dial to enter
RAIN SENSOR- NO the selection.
7.
Turn the Dial right one step to choose the
RAINSENSOR option. NO is selected by
default.
8. PresstheDial to select. Turn the Dial to
display the YES option to enable the option
for this program.
9. Repeatthisprocedureforeachprogram
numberaspreferred,beginningatstep4.
10. Whenfinished,presstheHOME
SETUP PROGRAM:- 2ET-ENABLED RAIN SENSOR[ NO ]
SETUP PROGRAM:- 2ET-ENABLED RAIN SENSOR[YES ]
key to return to the HOME screen.
SettingtheProgramWeatherOptions
23
RAIN MASTER TM EAGLE PLUS
Selecting the ET Setup Options
AllrequiredETconfigurationparametersareprovidedwithintheETSetupMenu
screen. The table below lists the available ET setup options and default settings.
ET Setup Menu
Manual Adjust
Reference ET
Reference Month
ET
Source
Option
No or .010 – .490
.00–.50
Jan–Dec
.00–.50
Historic, Internet
or Weather Station
key to display the SETUP
1. PresstheSETUP
menu. The CONTROLLER menu item is chosen
by default.
2. TurntheDial right four steps to choose ET,
then press the Dial to select.
Default
No
.10
Jan
.10
Historic
SETUP:
[CONTROLLER] –FLOW–PROGRAM–
–COMM–
–ET–
–TWO–WIRE–
SETUP:
-CONTROLLER- -FLOW-PROGRAM–COMM–
[ET]
–TWO–WIRE–
3. PresstheDial to display the SETUPET menu
screen. The MANUAL option is chosen by
default.
SETUP ET:MANUAL[NO ]
REFERENCE-.10MONTH-JAN- ET-.10SOURCE- HISTORIC -
4. PresstheDial to select. The default value will
beginflashing.TurntheDial to change the
value to the preferred setting. Press the Dial
to save.
SETUP ET:MANUAL-NO REFERENCE[.20]
MONTH-JAN- ET-.10SOURCE- HISTORIC -
5. TurntheDial tochoosethenextoptiontobeadjusted. Repeat the procedure
beginningatStep3.
6. Whenfinished,presstheHOME
24
SelectingtheETSetupPreferences
key to return to the HOME screen.
RAIN MASTER TM EAGLE PLUS
Selecting the Flow Sensor Setup and Operation Options
TheEaglePluscansupporttwoseparateflowsensorstocontinuouslymonitor
mainlineandindividualstationflowrates.Ifaflowrateisdetectedoutsidethe
specifiedparameter,anAlarmconditionistriggered.
ThecontrollersupportsStandardandCustomflowsensorconfigurations.The
Standardoptionappliesfactory-defaultKandOffsetvaluesforRainMasterflow
sensors.TheCustomoptionenablesKandOffsetvaluestobesetaspreferred.
Thetablebelowliststheflowsensorsetupoptions,anddefaultsettings.
Flow Setup Menu
Sensors
(Material/Size)
Usage
Type
Delay
Flow Limits
Learned Flow
Limit Adjust
Totalizer
Option
Bronze: 1.0”, 1.25”, 1.5”, 2.0” & 2.5“
PVC: 1.5”, 2.0”, 3.0“ & 4.0”
None, Flow 1, Flow 2, Flow 1 & Flow 2
Standard or Custom
1–6 Minutes
Station: 0–999 GPM
Main: 1–5000 GPM
Unscheduled: 0–999 GPM
1–All
5–80%
0–999,999 Gallons
Set the Sensor Enable/Disable Option
key to display the SETUP
1. PresstheSETUP
menu. The CONTROLLER menu item is chosen
by default.
2. TurntheDial right one step to choose FLOW,
then press the Dial to select and display the
SETUPFLOW screen.
3. TheSENSORS option is chosen by default.
Press the Dial to select.
4. TurntheDial to display ENABLED, then press
the Dial to enter the selection.
Note: SENSORS ENABLED must be selected to
access the remaining Flow setup features.
Default
1.5” PVC
Flow 1
Standard
2 Minutes
200 GPM
500 GPM
200 GPM
1
20%
0 Gallons
SETUP:
[CONTROLLER] –FLOW–PROGRAM–
–COMM–
–ET–
–TWO–WIRE–
SETUP:
-CONTROLLER- [FLOW]
–PROGRAM–
–COMM–
–ET–
–TWO–WIRE–
SETUP FLOW:
SENSORS [DISABLED]
USAGE-FLOW1 ONLY -MORESETUP FLOW:
SENSORS [ENABLED ]
USAGE-FLOW1 ONLY -MORE-
SelectingtheFlowSensorSetupandOperationPreferences
25
RAIN MASTER TM EAGLE PLUS
Setting the Usage Option
1. Turn the Dial to choose the USAGE option. The SETUP FLOW:
SENSORS -ENABLED FLOW 1 ONLY option is selected by default.
USAGE[FLOW1 ONLY ]
Press the Dial to select.
-MORE2. Turn the Dial to display the preferred option
(FLOW 1, FLOW 2, FLOW 1 & 2 or NONE).
Press the Dial to enter the selection.
SETUP FLOW:
SENSORS -ENABLED USAGE[FLOW2 ONLY]
-MORE-
3. Turn the Dial to choose the MORE option or
key.
press the Next
SETUP FLOW:
SENSORS -ENABLED USAGE-FLOW2 ONLY[MORE]
Setting the Standard/Custom Sensor Options
1. TheSETUPFLOW menu is displayed with the
SENSORS option chosen by default. Press the
Dial to select SENSORS.
2. TheSETUPFLOWSENSOR screen is displayed,
with the sensor number option chosen by
default. Press the Dial to select, then turn the
Dial to display SENSOR1or2. Press the Dial to
enter the selection.
3. TurntheDial to choose the STANDARD for
RainMasterflowsensororCUSTOM for alternate
flowsensormakes.PresstheDial to select.
SETUP FLOW:
[SENSOR] -DELAY–LIMITS– –LEARN–
–TOTALIZER–
SETUP FLOW SENSOR[2]
TYPE:
–STANDARD- -CUSTOM-
SETUP FLOW SENSOR-2TYPE:
[STANDARD] -CUSTOM-
•For Rain Master Flow Sensors:
4. ThesensorSIZEoption is chosen. Press the Dial SETUP FLOW SENSOR 2
to select, then turn the Dial to display the actual SIZE[ 2.00 INCH ]
sensorsize.PresstheDial to enter the selection.
•For Alternate Flow Sensors:
4. ThesensorOFFSET value option is chosen by
default. Press the Dial to select, then turn the
Dial todisplaythepreferredvalue(0–999).
Press the Dial to enter the selection.
SETUP FLOW SENSOR 2
OFFSET=[109]
K=0-
5. TurntheDial to choose the K value. Press the
Dial to select, then turn the Dial to display the
preferredvalue(0–32767).PresstheDial to
enter the selection.
SETUP FLOW SENSOR 2
OFFSET=-109K=[ 779]
26
SelectingFlowSensorSetupandOperationPreferences
RAIN MASTER TM EAGLE PLUS
Setting the Flow Limits Options
FlowratealarmcriteriaarebasedontheflowratevaluesspecifiedintheLIMITS
screen. In most cases, the factory default values can serve as a starting point
untiltheactualflowratevaluesareknown.UsingtheLearnedFlowprocedure
provided on Page 28,willenabletheactualflowratevaluestobeautomatically
acquiredandenteredinFlowLimitsscreeninlieuofsettingthevaluesmanually.
key to step back to the
1. PresstheBack
SETUPFLOWmenu.TurntheDial to choose
LIMITS.
SETUP FLOW:
-SENSOR- -DELAY[LIMITS] –LEARN–
–TOTALIZER–
2. TheStation number option is chosen by
default. Press the Dial to select, then turn the
Dial to display the preferred station number.
Press the Dial to enter.
SETUP LIMITS: (GPM)
STATION[ 2] -200MAIN LINE-500UNSCHEDULED-200-
3. TurntheDial to choose the STATIONflow
SETUP LIMITS: (GPM)
STATION- 2- [175]
limit. Press the Dial to select, then turn the
MAIN LINE-500Dial to display the preferred value from
UNSCHEDULED-2000 to 999. Press the Dial to enter the selection.
IMPORTANT: When the PROGRAM STACKING option is not used, multiple
programs/stations are allowed to operate simultaneously. The MAIN LINE
flow limit must be set to correspond with the maximum cumulative flow
rate during multi- program operation.
4. TurntheDial to choose the Main Lineflow
SETUP LIMITS: (GPM)
STATION- 2- -175limit. Press the Dial to select, then turn the
MAIN LINE[450]
Dial to display the preferred value from
UNSCHEDULED-2000 to 9999. Press the Dial to enter.
Note: Setting the Unscheduled flow limit establishes the maximum allowable
flow through the main line while the irrigation system is static. If the flow rate
exceeds the limit, an Alarm is triggered and the system will shut down until
the cause is resolved. A small or zero value for unscheduled flow is generally
sufficient unless supplemental irrigation is used; i.e., via a quick-coupler or gate
valve. In this case, the Unscheduled flow limit must be set at the maximum
supplemental flow rate.
5. TurntheDial to choose the UNSCHEDULED
flowlimit.PresstheDial to select, then turn
the Dial to display the preferred value from
0 to 999. Press the Dial to enter the selection.
SETUP LIMITS: (GPM)
STATION- 2- -175MAIN LINE- 450UNSCHEDULED[ 0]
SelectingFlowSensorSetupandOperationPreferences
27
RAIN MASTER TM EAGLE PLUS
Setting the Delay Option
TheDelaytimeenteredinthissetupscreendetermineshowlongastationwill
runbeforetheflowdataissampled.
Note: An extra 10 seconds will be added to the selected Delay time.
key to step back through the SETUP FLOW:
1. PresstheBACK
[SENSOR] -DELAYmenu sequence to the SETUPFLOW menu.
–LIMITS– –LEARN–
–TOTALIZER–
2. TurntheDial right one step to choose the
DELAY option. Press the Dial to select.
3. TheSETUPFLOWDELAYscreenisdisplayed
with the delay time chosen by default. Press
the Dial to select, then turn the Dial to display
the preference from 1 to 6 minutes. Press the
Dial to enter the selection.
SETUP FLOW:
-SENSOR- [DELAY]
–LIMITS– –LEARN–
–TOTALIZER–
SETUP FLOW DELAY
DELAY[2] MINUTES
BEFORE LIMIT CHECKS
ARE PERFORMED
Setting the Learned Flow Options
DuringtheLearnedFlowprocedure,eachstationassignedtoaselectedprogram
isoperatedinsequencefortheruntimespecifiedintheDelayoptionscreen.
Anadditional10secondsisaddedattheendofthedelayperiodinwhichthe
nominalflowrateisacquired.TohelppreventfalsethresholdAlarmsduetotypical
variationsinflowrate,thecontrollerestablishesthemaximumflowratevalueby
increasingthenominalflowratebyaspecifiedpercentagefactorfrom5to80%.
Note: To utilize the learned flow feature, at least one valid automatic watering
program must be defined.
key to step back to the
1. PresstheBACK
SETUPFLOW menu. Turn the Dial to choose the
Learn option, then press the Dial to enter the
selection.
SETUP FLOW:
-SENSOR- -DELAY–LIMITS– [LEARN]
–TOTALIZER–
Note: Established programs can be selected by number, or when more than one
valid program exists, the ALL option will be displayed. When the ALL option is
selected, all valid programs will run one at a time in numeric sequence.
2. TheSETUPLEARNEDFLOW menu is displayed,
with the program number option chosen by
default. Press the Dial to select, then turn the
Dial to display a specific program number,
or select All to run all programs in sequence.
28
SelectingFlowSensorSetupandOperationPreferences
SETUP LEARNED FLOW:
LEARN PROGRAM[ALL]
ADJUST LIMIT BY-20-%
-START-
RAIN MASTER TM EAGLE PLUS
3. TurntheDial to choose the ADJUSTLIMIT value. SETUP LEARNED FLOW:
Press the Dial to select, then turn the Dial to
LEARN PROGRAM-ALLADJUST LIMIT BY[20]%
display the preferred increase from 5 to 80%.
-STARTTurn the Dial to choose START, then press the
Dial to select.
4. AWARNINGscreenisdisplayed.Thestationrun WARNING: EACH
time(DELAY)timeplus10secondsisindicated, STATION WILL TURN ON
FOR:130
and the STARToption is chosen by default.
[START] -CANCELNote: Choosing and selecting the CANCEL option
discontinues the procedure and reverts to the
SETUP LEARNED FLOW screen.
5. PresstheDialtostarttheoperation.Astatus
SETUP LEARNED FLOW:
screen will be displayed identifying the station ADJUST LIMIT BY 20%
STATION: 1 154 GPM
numberbeingtested,thecurrentflowrate,
TIME:01:05 [ABORT]
and the run time remaining.
Note: Choosing and selecting the ABORT option discontinues the procedure and
reverts to the SETUP LEARNED FLOW screen.
Resetting the Flow Totalizer
Allflowsensordataisstoredinthecontrollermemoryandcanbereviewedat
anytime.Theflowtotalizerfeaturemonitorstheflowdataregisteredbyeach
flowsensoranddisplaysthecombinedtotalvolume.Thetotalizercanbesetto
displayflowdatainGAL(gallons),CCF(100cubicfeet),orACRE-FEET(ACF)as
preferred. TheRESETfeatureenablesthetotalizertoberesettozeroandbegin
compilingtotalflowdatafromthatpointforward.
key to step back to the
1. PresstheBACK
SETUP FLOW:
SENSORFLOWmenu. Turn the Dial to choose -SENSOR- -DELAY–LIMITS– -LEARNthe TOTALIZER option. Press the Dial
[TOTALIZER]
to select.
2. TheGAL(gallons)displayunitsoptionischosen SETUP TOTALIZER:
FROM02/18/10 01:00PM
by default. To select an alternate unit of mea[GAL]
sure, press the Dial to select, then turn the Dial TOTAL=21440
-RESET TOTALto display the preferred option. Press the Dial to
enter the selection.
Note: The TOTAL will be automatically converted to the equivalent unit measure.
3. TurntheDial to choose RESETTOTAL.
Press the Dialtoresetthetotalizerto0.
The previous date and time will is updated
tothecurrentdateandtime.Alldatawillbe
logged beginning at this time and date.
SETUP TOTALIZER:
FROM04/08/11 02:33PM
TOTAL=0
-CCF[RESET TOTAL]
SelectingFlowSensorSetupandOperationPreferences
29
RAIN MASTER TM EAGLE PLUS
Setting the Communications Options
Note: The iCentral TM interface board and external antenna must be installed to
access and utilize the following controller functions.
TheEaglePluscantakefulladvantageoftheiCentralcapabilitieswhenequipped
withtheoptionaliCentralinterfaceboardandantenna.Additionalfunctions
include,remoteprogramming,ZipETTM evapotranspiration data, and the
SmartAlertsTM , comprehensive alert messaging.
Thestraight-forwardcommunicationsetupoptionsinclude:Enable,Disable,
andTest.Thecommunicationstestcheckssignalstrengthandtwo-way
communicationswiththeiCentral.The60-secondtestismonitoredasit
progresses.Whentestinghasconcluded,therelativesignalstrengthisratedas:
Excellent,Good,Fair,Poor,orNone.Inaddition,aCSQvaluefrom0–32isprovided.
key to display the SETUP
1. PresstheSETUP
menu. Turn the Dial to choose COMM.
2. PresstheDial to display the SETUPCOMMUNICATION screen. The ENABLED option is chosen
by default.
3. TurntheDial to select START, then press the
Dial to initiate the test.
4. Thecount-downscreenwillbedisplayed.
•Toterminate the test, press the BACK
•Theresultswillbedisplayedatthe
conclusion.
key.
SETUP:
-CONTROLLER- -FLOW–PROGRAM–
[COMM]
–ET–
–TWO–WIRE–
SETUP COMMUNICATION:
COMM[ENABLED ]
COMM CARD: PRESENT
COMM TEST-STARTSETUP COMMUNICATION:
COMM-ENABLED COMM CARD: PRESENT
COMM TEST[START]
COMMUNICATION TEST:
TIME REMAINING: 53
COMMUNICATION TEST
SIG STRENGTH: GOOD
ICENTRAL TEST:PASS
CSQ: 10
Note: If the signal strength is NONE or POOR,
and/the or the CSQ number is low, and/or FAIL
is indicated, contact Rain Master technical
support at 1-800-777-1477 for recommended
troubleshooting procedures.
30
SettingtheCommunicationsOptions
COMMUNICATION TEST
SIG STRENGTH: POOR
ICENTRAL TEST:FAIL
CSQ: 1
RAIN MASTER TM EAGLE PLUS
Two-Wire Decoder System Setup
WhentheEaglePlusisequippedwiththeTwo-WireDecoderinterfaceboard,
accesstotheTwo-Wiresetupmenuoptionsbecomeavailable.Thesetup
functionsfortheTwo-WireDecodersysteminclude:
• Program Decoder –ProvidesDecoderprogrammingandsetupoptions.
• Show Stations – Retrieves and displays current station address information.
• Test–ProvidesmultipletestfunctionsforDecoderstationaddressverification.
Note: If the decoder board is not installed or a
SETUP TWO-WIRE
TWO-WIRE BOARD NOT
hardware malfunction has occurred, the prompt
FUNCTIONING OR NOT
screen shown at right will be displayed.
PRESENT.
Programming the Decoders
RainMasterdecodersareavailablein1-,2-,and4-stationoutputmodels,and
asshippedfromthefactory,havenopre-definedstationassignments.Tobe
recognizedbytheEaglePluscontroller,eachstationmustbeaddressedaseither
astationnumberfrom0–200,aMasterValve,oraPumpcontrol.Tofacilitate
decoderprogramming,aquick-connectterminalblockisprovidedonthe
Two-WireDecoderboard.
Note: The Eagle Plus enables the decoders to be temporarily connected and
programmed without disconnecting power. Confirm the Power LED on the Decoder
board is illuminated before continuing. If it is not illuminated, confirm that power is on
and the Decoder board is properly connected to Control Module.
CAUTION: Red and Black decoder wires must be connected to the decoder
board terminal block in the correct orientation. Damage to the decoder and/
or controller may result from crossing the wire connection.
1. Inserttheredandblackdecoderleadsintothecorrespondingquick-release
terminal connectors as indicated below.
Cable to Control
Module
Red Wire Lead
Black Wire Lead
Power LED
Status LED
Status LED
Decoder Board
Decoder
Two-WireDecoderSystemSetup
31
RAIN MASTER TM EAGLE PLUS
2. PresstheSETUP
key to display the SETUP
SETUP:
-CONTROLLER- -FLOWmenu. The CONTROLLERmenu item is chosen
–PROGRAM–
–COMM–
by default. Turn the Dial right five steps to
–ET–
[TWO–WIRE]
choose the TWO-WIRE menu option, then press
the Dial to select.
3. TheSETUPTWO-WIRE menu screen is
SETUP TWO-WIRE
displayed with PROGRAMDECODERoption
[PROGRAM DECODER]
chosen by default. Press the Dial to select.
-SHOW STATIONS-TESTStatusLEDsontheDecoderBoardand
Decodershouldbeginblinkingtoconfirm
communication.
Note: If the Decoder Status LED does not illuminate periodically, confirm the
red and black lead wires are properly connected to the terminal block. A faulty
decoder is indicated if the Status LED does not illuminate.
4. ThePROGRAMDECODER screen is displayed
PROGRAM DECODER:
with the NEWADDRESS option chosen.
CURRENT ADDRESS:NONE
Note: In this example, NONE indicates that
NEW ADDRESS[NONE]
-1- OF 4 -PROGRAMdecoder station slot 1 (of 4 available slots)
has no programmed address.
5. Toselectadifferentdecoderstationslot
PROGRAM DECODER:
number, turn the Dial to choose the slot
CURRENT ADDRESS:NONE
NEW ADDRESS[NONE]
number, then press the Dial to select. Turn
the Dial to display the preferred number, then [2] OF 4 -PROGRAMpress the Dial to enter the selection.
6. PresstheDialtochooseNEWADDRESS.Turn
PROGRAM DECODER:
CURRENT ADDRESS:NONE
the Dial to display the preferred address
NEW ADDRESS[012]
(001–200,MV,PMPorNONE),thenpressthe
-2- OF 4 -PROGRAMDial to enter. In this example, station number 12
will be assigned to decoder station slot 2 of 4.
7. Turn the Dial to choose PROGRAM, then
PROGRAM DECODER:
press the Dial to begin the procedure. Within
CURRENT ADDRESS:NONE
NEW ADDRESS-012a few moments the results will be displayed.
-2- OF 4 [PROGRAM]
If programming was successful, OK will be
momentarily displayed in the upper right
PROGRAM DECODER: OK
corner,andthenextdecoderstationnumber
CURRENT ADDRESS:FAIL
in sequence will be displayed. If programming NEW ADDRESS-012-3- OF 4 [PROGRAM]
wasnotsuccessful,FAILwillbedisplayedand
anAlarmwillbegenerated.
Note: To clear the Alarm, refer to Resolving Alarms, page 52.
8. Repeattheprogrammingprocedureforalldecoderstationsasrequired.
32
Two-WireDecoderSystemSetup
RAIN MASTER TM EAGLE PLUS
Testing the Two-Wire Decoder System
The Two-Wire Decoder system test feature provides methods of testing the
decoder installation to easily verify communication, station assignment and
operating status and log the results. The following test options are available:
• Single Station: Tests a selected Decoder station number.
• Find Decoders: Searches communication path for all responding Decoders.
• All Programmed: Tests all decoder stations (1–200, Master Valve or Pump) that
have been defined within a program.
• All Stations: Tests all decoder stations, Master Valve and Pump controls.
• Alarm Logging Options: Test results can be logged as Alarms indicating Pass
and/or Fail as selected.
••Log Fail Alarm: When selected, a decoder station that fails the test criteria
will be logged.
••Log Pass Alarm: When selected, a decoder station that passes the test
criteria will be logged
Single Station Test
1. Press the SETUP
key to display the SETUP
menu. Turn the Dial to choose the TWO-WIRE
option, then press the Dial to select.
SETUP:
-CONTROLLER- -FLOW–PROGRAM–
–COMM–
–ET–
[TWO–WIRE]
2. The SETUP TWO-WIRE menu screen is displayed
with the PROGRAM DECODER option chosen by
default. Turn the Dial to choose the TEST option,
then press the Dial to select.
SETUP TWO-WIRE
-PROGRAM DECODER-SHOW STATIONS[TEST]
3. The SETUP TWO-WIRE TEST screen is displayed
with SINGLE STATION test type chosen by
default.
SETUP TWO-WIRE TEST
TYPE[SINGLE STATION]
LOG FAILURES-YESLOG PASS-YES- -GO-
4. Turn the Dial to choose the LOG FAILURES
option. To change the current setting, press the
Dial to select, then turn the Dial to display the
preference. Repeat this procedure for the LOG
PASS option as preferred.
SETUP TWO-WIRE TEST
TYPE-SINGLE STATIONLOG FAILURES[NO ]
LOG PASS-YES- -GO-
5. TurntheDial to choose GO, then press the Dial SETUP TWO-WIRE TEST
TYPE-SINGLE STATIONto continue.
LOG FAILURES-NO LOG PASS-YES- [GO]
Two-WireDecoderSystemSetup
33
RAIN MASTER TM EAGLE PLUS
6. TheSINGLESTATIONTESTscreenwillbedisplayed
displayed SINGLE STATION TEST
STATION[ 1]
with STATION 1 chosen by default.
To change the station selection, press the Dial
-GOto select, turn the Dial to display the preferred
station number, then press the Dial to enter.
7. Turn the Dial to choose GO, then press the Dial SINGLE STATION TEST
to start the test.
STATION- 1Note: The test will take approximately 3 minutes.
8. The test results will be displayed. Based on the
AlarmLogoptionsselected,analarmmaybe
generated.
[GO]
SETUP TWO-WIRE TEST:
TESTING STATION: 12
TESTING CURRENT: .18
VERSION: 0
[STOP]
Note: To pause or stop the test, turn the Dial to
choose STOP, then press the Dial to pause the test.
To resume the test, press the Dial again.
To terminate the test, press the BACK
key.
9. Press the HOME
key to return to the Home
WE 02:47:41P WK1
screen. Turn the Dial to choose ALARMS, then
VALID PGM:NONE
press the Dial to review the Alarm screen.
-MAIN-[ALARMS( 1)]
10. Turn the Dial to choose CLEAR, then press the
Dial to clear the alarm.
Note: Clearing alarms removes the screen
prompts and turns off the Alarm LED indicator.
Logged alarm information is accessed from the
REVIEW menu screen.
06/16 WE 02:48:01P
STATION 12
DECODER FOUND
[CLEAR]
Find Decoders Test
1. Press the SETUP
key to display the SETUP
menu. Turn the Dial to choose the TWO-WIRE
option, then press the Dial to select.
SETUP:
-CONTROLLER- -FLOW–PROGRAM–
–COMM–
–ET–
[TWO–WIRE]
2. The SETUP TWO-WIRE menu screen is displayed
with the PROGRAM DECODER option chosen by
default. Turn the Dial to choose TEST, then press
the Dial to select.
SETUP TWO-WIRE
-PROGRAM DECODER[SHOW STATIONS]
-TEST-
3. The SETUP TWO-WIRE TEST screen is displayed
with SINGLE STATION test type chosen by
default. Press the Dial to select, then turn the
Dial to display FIND DECODERS.
SETUP TWO-WIRE TEST
TYPE[FIND DECODERS ]
LOG FAILURES-YESLOG PASS-YES- -GO-
34
Two-WireDecoderSystemSetup
RAIN MASTER TM EAGLE PLUS
4. Turn the Dial to choose the LOG FAILURES
option. To change the current setting, press the
Dial to select, then turn the Dial to display the
preference. Repeat this procedure for the LOG
PASS option as preferred.
SETUP TWO-WIRE TEST
TYPE-SINGLE STATIONLOG FAILURES[NO ]
LOG PASS-YES- -GO-
5. TurntheDial to choose GO, then press the Dial SETUP TWO-WIRE TEST
TYPE-SINGLE STATIONto begin the test.
LOG FAILURES-NO Note: The test will take approximately 3 minutes. LOG PASS-YES- [GO]
6. Thetestresultswillbedisplayed.Basedonthe
Alarm Log options selected, an alarm may be
generated.
SETUP TWO-WIRE TEST:
TESTING STATION: 12
TESTING CURRENT: .18
VERSION: 0
[STOP]
Note: To pause or stop the test, turn the Dial to
WE 02:47:41P WK1
choose STOP, then press the Dial to pause the test. VALID PGM:NONE
To resume the test, press the Dial again.
-MAIN-[ALARMS( 1)]
To terminate the test, press the BACK
key.
7. Press the HOME
key to return to the Home screen. Turn the Dial to choose
ALARMS, then press the Dial toreviewtheAlarmscreen.
All Stations Test
Note: To run the ALL STATIONS test, refer to the FIND DECODERS test procedure on the
previous page. Select the ALL STATIONS option in lieu of FIND DECODERS in step 3.
Show Stations
1. PresstheSETUP
key to display the SETUP
menu. Turn the Dial to choose the TWO-WIRE
option, then press the Dial to select.
2. TheSETUPTWO-WIRE menu screen is displayed
with the PROGRAMDECODER option chosen
by default. Turn the Dial to choose SHOW
STATIONS, then press the Dial to begin.
Note: The test will take approximately 3 minutes.
3. Thecontrollerwillsearchforallstationsassigned
toanyofthe16wateringprograms.Theresults
will be display on one or more sequential
screens Press the NEXT
and BACK
keys
to access and review the screens.
SETUP:
-CONTROLLER- -FLOW–PROGRAM–
–COMM–
–ET–
[TWO–WIRE]
SETUP TWO-WIRE
-PROGRAM DECODER[SHOW STATIONS]
-TESTCALCULATING
SHOW PROGRAMMED
TWO-WIRE STATIONS:
1,3,5,7,10-37,40,44
49-57,59-83,87-108
Two-WireDecoderSystemSetup
35
RAIN MASTER TM EAGLE PLUS
Programming for Automatic Operation
The Eagle Plus enables you to define up to 8 automatic programs for a
conventional control system, or up to 16 programs for a decoder system.
A program is comprised of the following three primary operating parameters
that must be established to create a valid program:
• An active day schedule
• A program start time
• A station run time.
The operating options selected within the various Setup menus are applied to
the programs to further define and regulate controller operations.
IMPORTANT: A program becomes valid only after all three primary
operating parameters have been entered. Once a valid program is entered,
all user-defined program values will remain intact. Failing to enter all three
parameters correctly, or prior to the display timing-out, will invalidate that
program. It is recommended to always confirm the valid program status
whenever creating or modifying programs.
Creating a New Program
Setting a Two-Week Watering Schedule
key to display the
1. PressthePROGRAM
PROGRAM menu. The MODIFY menu item is
chosen by default. Turn the Dial to choose
the NEW option, then press the Dial to select.
2. TheNEWPROGRAM screen is displayed with
the program number chosen by default.
To change the program number assignment,
press the Dial to select, then turn the Dial to
change the program number. Press the Dial to
enter the selection.
3. TurntheDial to choose CREATEPROGRAM,
then press the Dial to select.
PROGRAM:
-MODIFY-REVIEW-COPY-
[NEW]
-DELETE-
NEW PROGRAM
VALID PGM:1-3
[ 3]
-CREATE PROGRAM-
NEW PROGRAM
VALID PGM:1-3
- 3-
[CREATE PROGRAM]
Note: If the program number selected is already
an established (valid) program, a prompt screen
will be displayed. Selecting YES will overwrite
the existing program; selecting NO will leave
the program unchanged. Repeat Step 2 and 3 to
select an available program number, then
continue to Step 4.
36
CreatingaNewProgram
ARE YOU SURE YOU
WANT TO DELETE
EXISTING PROGRAM
-YES- [NO]
3?
RAIN MASTER TM EAGLE PLUS
4. Thetwo-weekschedulescreenisdisplayed
with S (Sunday) of W1 (Week1) chosen by
default.
NEW PROGRAM:1
S M T W T F S
[ ]
W1*
W2
5. Toselecttheday,presstheDial(anX will
NEW PROGRAM:1
appear),ortoskiptheday,turntheDial to the
S M T W T F S
[ ]
preferred day, then press the Dial to select.
Note: Pressing the Dial repeatedly toggles the
selection ON and OFF.
6. Continuetodefinetheremainingdaysofthe NEW PROGRAM:1
S M T W T F S
two-weekscheduleinthismanner.
Note: The asterisk next to W1 or W2 indicates
the current week of the two-week watering cycle
and is not pertinent to the programming
procedure.
NEW PROGRAM:1
S M T W T F S
7. Whenthetwo-weekscheduleisset,select
key to display the
OK, or press the NEXT
STARTTIME setup screen.
-OKW1*
W2
[OK]
W1*
W2
[OK]
W1*
W2
Setting a Skip-Day Watering Schedule
Note: The Skip Days scheduling option will not be available for the selected program
unless it is initially assigned to the program within the Program Setup menu>Type
options. See page 20 for Skip Day information and setup procedures.
1. TurntheDial to choose the SKIPDAYS value. NEW PROGRAM: 1 -OKPress the Dial to select, then turn the Dial to
SKIP [03] DAYS
BETWEEN WATERING.
display the number of days between active
START IN -00- DAYS
wateringdays(0–30).PresstheDial to enter.
Note: To water every day, select 0. To water
every-other-day, select 1, etc.
2. TurntheDial to choose theSTART delay
NEW PROGRAM: 1 -OKSKIP -03- DAYS
value. Press the Dial to select, then turn the
BETWEEN WATERING.
Dial to display the number of days before
START IN [02] DAYS
startingtheskipdaycycle(0–30).Pressthe
Dial to enter.
Note: To start the watering day cycle today
select 0; to start tomorrow select 1, etc.
NEW PROGRAM: 1 [OK]
SKIP -03- DAYS
3. WhentheSKIPDAY setup values are set,
BETWEEN WATERING.
key to
select OK, or press the NEXT
START IN -02- DAYS
display the STARTTIME setup screen.
SettingaSkip-DayWateringSchedule
37
RAIN MASTER TM EAGLE PLUS
Setting Program Start Times
1. Eachprogramcanhaveupto8starttime
assignments. STARTTIME1 is selected by
default.
2. TurntheDial to choose HH:MM. The start time
will default to 12:00AM with the hour digits
selected(blinking).
3. TurntheDial to set the start time hour, then
press the Dial to enter. The minutes digits will
beginblinking.Setthestarttimeminutesand
AM/PMdesignatorinthesamemanner.
NEW PROGRAM: 1
TOTAL START TIMES:1
START TIME[1]
-HH:MM - -DELETENEW PROGRAM: 1
TOTAL START TIMES:0
START TIME-1[12:00AM] -DELETENEW PROGRAM: 1 -OKTOTAL START TIMES:0
START TIME-1[ 6:15AM] -DELETE-
4. STARTTIME2 is prompted as STARTTIME1 is NEW PROGRAM: 1 -OKentered.Continuetoassignupto8starttimes TOTAL START TIMES:1
START TIME-2for this program as preferred.
[HH:MM ] -DELETE5. Whenfinished,chooseandselectOK,
key to display the
or press the NEXT
STATIONRUNTIME setup screen.
Note: To clear the displayed start time, choose and select the DELETE option.
Assigning the Station Run Time
Note: If the CYCLE AND SOAK option was selected for the program, continue at
Setting a Cycle and Soak Station Run Time on the next page.
1. STATION1 is selected by default. To change the NEW PROGRAM: 1
STATION [ 1]
station number, press the Dial to select. Turn
the Dial to display the preferred station number, RUNTIME-00:00then press the Dial to enter the selection.
2. TurntheDial to choose the station run time
NEW PROGRAM: 1
STATION - 1value, then press the Dial to select. The hours
RUNTIME[ 0:00]
digit is selected and will begin blinking.
3. TurntheDial to display the preferred run time
hours(0–23),thenpresstheDial to enter. The
minutes digits will be selected. Turn the Dial
toselecttheruntimeminutes(0–59),then
press the Dial to enter.
4. Thenextstationnumberinsequencewillbe
prompted.Continuetoassignadditional
stations to this program as preferred.
38
SettingProgramStartTimesandStationRunTime
NEW PROGRAM: 1
STATION- 1RUNTIME[ 1:15]
NEW PROGRAM: 1
STATION- 2RUNTIME-00:00-
[OK]
RAIN MASTER TM EAGLE PLUS
5. PresstheNEXT
key to display the
PROGRAMsummary screen.
Note: If the program is not valid, press the
BACK
key to recall, correct, and/or adjust
the various program setup parameters as
necessary. When the summary screen indicates
that the program is valid, choose and select OK.
PROGRAM: 1 NOT VALID
TOTAL RUNTIME:00:00
[OK]
PROGRAM: 1 IS VALID
TOTAL RUNTIME:06:45
[OK]
Setting a Cycle and Soak Station Run Time
Note: The Cycle and Soak scheduling option will not be available for the selected
program unless it is initially assigned to the program within the PROGRAM SETUP>
TYPE menu. See page 20 for the Cycle and Soak setup procedure.
1. Station1 is selected by default. To change the
station number, press the Dial to select. Turn
the Dial to display the preferred station number, then press the Dial to select.
NEW PROGRAM: 1
STATION[ 1]
MAX-0:00-SOAK-0:00RUNTIME-00:00-
Important: Any station assigned to the program with a 0:00 MAX or
SOAK time value will not operate during the program watering cycle.
2. TurntheDial to choose the MAX run time value,
then press the Dial to select. The hour digit is
selected and will begin blinking. Turn the Dial
todisplaytheruntime(0–9hours),thenpress
the Dial to select.
NEW PROGRAM: 1
STATION- 1MAX[1:00]SOAK-0:00RUNTIME-00:00-
3. Theminutesdigitswillbeselected(blinking).
Turn the Dial to select the run time minutes
(0–59),thenpresstheDial to enter.
NEW PROGRAM: 1
STATION- 1MAX[1:05]SOAK-0:00RUNTIME-00:00-
4. TurntheDial to choose the SOAKtime value,
then press the Dial to select. The hour digit
is selected and will begin blinking. Turn the
Dialtodisplaythesoaktime(0–9 hours),then
press the Dial to select.
NEW PROGRAM: 1
STATION- 1MAX-1:05-SOAK[2:00]
RUNTIME-00:00-
5. Theminutesdigitswillbeselected.Turnthe
Dial to select the RUNTIMEminutes(0–59),
then press the Dial to enter.
NEW PROGRAM: 1
STATION- 1MAX-1:05-SOAK[2:30]
RUNTIME-00:00-
SettingaCycleandSoakStationRunTime
39
RAIN MASTER TM EAGLE PLUS
6. TurntheDial to choose the RUNTIMEvalue,
then press the Dial to select. The hours digits are
selected and will begin blinking. Turn the Dial to
displaytheruntime(0–23 hours),thenpressthe
Dial to enter. The minutes digits will be selected.
7.
NEW PROGRAM: 1
STATION- 1MAX-1:05-SOAK-2:30RUNTIME[00:00]
Turn the Dial to select the RUNTIME minutes
NEW PROGRAM: 1
(0–59),thenpresstheDial to enter the selection. STATION- 1MAX-1:05-SOAK-2:30RUNTIME[04:50]
8. Thenextstationnumberinsequencewillbe
prompted.Continuetoassignadditional
stations to this program as preferred.
When finished, choose and select OK, or press
the NEXT
key to display the PROGRAM
summary screen.
Note: The Program summary screen enables you
to quickly verify the status and total run time of
the program. If the program is not valid, press the
BACK
key to recall, correct and/or adjust the
various program setup parameters as necessary.
NEW PROGRAM: 1 -OKSTATION- 2MAX-0:00-SOAK-0:00RUNTIME[00:00]
PROGRAM: 1 NOT VALID
TOTAL RUNTIME:00:00
[OK]
PROGRAM: 1 IS VALID
TOTAL RUNTIME:06:45
[OK]
9. Whenfinished,chooseandselectOK to complete the setup requirements for
the selected program.
40
SettingaCycleandSoakStationRunTime(continued)
RAIN MASTER TM EAGLE PLUS
Modifying a Program
TheModifyProgramfeatureprovidesaconvenientwaytoaccessandadjustany
parameterofanestablishedprogramincluding:
•Days–Two-WeekandSkipDaysschedules
•Runtime–Stationruntimeassignment
•Start–Starttimeassignments
•Percent–RunTimeadjustmentbypercentageforallassignedstations.
key to display the
1. PressthePROGRAM
PROGRAM menu. The MODIFY menu item is
chosen by default. Press the Dial to select.
2. Theprogramnumberischosenbydefault.
To change the program number assignment,
press the Dial to select, then turn the Dial to
display the preferred number. Press the Dial
to enter the selection.
3. TurntheDial to choose a portion of the
program to be modified. Press the Dial to
display the initial modification screen.
PROGRAM:
[MODIFY]
-REVIEW-COPY-
-NEW-DELETE-
MODIFY PROGRAM[1]
-DAYS-RUNTIME-START-PERCENTMODIFY PROGRAM-1[DAYS]
-RUNTIME-START-PERCENT-
Note: The PROGRAM setup options defined for DAYS, STATION RUN TIMES and
START TIMES are utilized for the modification procedures. To assist in the modification process, refer to the corresponding PROGRAM SETUP procedures, beginning
on page 36
Modifying a Program
41
RAIN MASTER TM EAGLE PLUS
Adjusting Program Percent Value
To account for changes in season or weather, the total operating duration for any
established program cycle time can be easily increased or decreased by a percentage factor from 0%–300%, in 1% increments. The run time for each station
assigned to the program will be modified by the percentage change.
IMPORTANT: Increasing the program cycle duration can result in a conflict
with other scheduled watering programs and/or the defined Water Window
duration. The recommended method of increasing run time by percentage
is to make small, incremental changes while monitoring the results over a
period of time.
1. FromtheMODIFYPROGRAM menu screen,
turn the Dial to choose PERCENT, then press
the Dial to select.
MODIFY PROGRAM-1-DAYS-RUNTIME-START[PERCENT]
2. TurntheDial to choose the PERCENTvalue.
Press the Dial to select, then turn the Dial to
displaythepreferredpercentvalue(0–300).
Press the Dial to enter the selection.
MODIFY PROGRAM- 1PERCENT[100]
3. Repeatprocedureforeachprogramasneeded.
Deleting a Program
TheDeleteProgramfeatureprovidesaconvenientmethodofaccessingand
clearing all established operating parameters from a specified program.
key to display the
1. Pressthe PROGRAM
PROGRAM menu. Turn the Dial to choose the
DELETE option, then press the Dial to select.
2. TurntheDial to choose the PROGRAM number.
Press the Dial to select, then turn the Dial to
display the PROGRAM number to delete. Press
the Dial to enter the selection.
3. Adecisionscreenwillbepromptedwiththe
YES option chosen. TocompletetheDelete
function, press the DialtoenterYES.Toabort
theDeletefunctionandreturntotheprevious
screen,chooseandselecttheNOoption.
42
AdjustingandDeletingaPrograms
PROGRAM:
-MODIFY-REVIEW-COPY-
-NEW[DELETE]
DELETE PROGRAM[ 1]?
TOTAL STATIONS: 6
TOTAL START TIMES:3
-YES- -NOARE YOU SURE YOU
WANT TO DELETE
PROGRAM 1?
[YES] -NO-
RAIN MASTER TM EAGLE PLUS
Copying a Program or Runtime
TheCopyfunctionprovidesaconvenientmethodoftransferringallprogram
setup parameters* from one program to another, or to apply a specific station
run time to multiple stations. When setting up multiple programs with
similar attributes, the copy functions will not only reduce the setup time by
eliminating redundant tasks, but will help ensure consistency throughout the
overall watering program setup structure.
*Note: Program attributes include: watering day schedule, station run time, cycle
and soak time, start times and percent adjust factor.
To Copy a Program:
key to display the
1. PressthePROGRAM
PROGRAMmenu. Turn the Dial to choose
the COPY option, then press the Dial to select.
PROGRAM:
-MODIFY-REVIEW[COPY]
2. TurntheDial to choose the Copy Program
option, then press the Dial to select.
COPY FUNCTION:
[COPY PROGRAM]
-COPY RUNTIME-
-NEW-DELETE-
3. PresstheDial to choose the COPYPROGRAM COPY PROGRAM[ 1]
TO
number. Press to select, then turn the Dial
PROGRAM- 1to display the PROGRAM number to be copied
-OKfrom. Press the Dial to enter the selection.
4. TurntheDial to choose the TOPROGRAM
COPY PROGRAM- 1TO
number. Press to select, then turn the Dial
PROGRAM[ 2]
to display the recipient program number.
-OKPress the Dial to enter the selection.
COPY PROGRAM- 15. TurntheDial to choose OK, then press
TO
the Dial to enter the selection.
PROGRAM[ 2]
[OK]
Note: A decision screen will be prompted with
WARNING:PROGRAM
2
the OK option chosen by default.
WILL BE OVERWRITTEN
To complete the Copy function, press the Dial
[OK] -CANCELto begin the Copy function. To abort the Copy
function and return to the previous screen, choose
and select the CANCEL option.
6. Uponcompletionofthecopyfunction,the
COPY FUNCTION:
initialCOPYFUNCTIONscreenwillbedisplayed. [COPY PROGRAM]
Repeat the procedure for additional programs [COPY RUNTIME]
as preferred.
CopyFunctions
43
RAIN MASTER TM EAGLE PLUS
To Copy a Run Time:
key to display the
1. PressthePROGRAM
PROGRAM menu. Turn the Dial to choose the
COPY option, then press the Dial to select.
PROGRAM:
-MODIFY-REVIEW[COPY]
2. TurntheDial to choose the COPYRUNTIME
option, then press the Dial to select.
COPY FUNCTION:
[COPY PROGRAM]
[COPY RUNTIME]
3. TheCOPYRUNTIMEscreen is displayed with
the run time value chosen. Press the Dial
to select, then turn the Dial to display the
preferredruntimehours(0–23).Repeatto
selecttheruntimeminutes(0–59).
4. TurntheDial to choose TOPROGRAM. Press
the Dial to select, then turn the Dial to display
the recipient program number. Press the Dial
to enter the selection.
-NEW-DELETE-
COPY RUNTIME[00:15]
TO PROGRAM- 1BEGIN STATION- 1END STATION- 1-OK-
COPY RUNTIME-00:15TO PROGRAM[ 1]
BEGIN STATION- 1END STATION- 1-OK-
Note: All station numbers, inclusive from the
BEGIN and END station numbers entered, will
receive the specified run time assignment.
5. TurntheDial to choose BEGINSTATION. Press
the Dial to select, then turn the Dial to display
the preferred beginning station number. Press
the Dial to enter the selection.
COPY RUNTIME-00:15TO PROGRAM- 1BEGIN STATION[ 9]
END STATION- 1-OK-
6. TurntheDial to choose ENDSTATION. Press
the Dial to select, then turn the Dial to display
the preferred station number. Press the Dial to
enter the selection.
COPY RUNTIME-00:15TO PROGRAM- 1BEGIN STATION- 9END STATION[ 18]OK-
7.
Turn the Dial to choose OK, then press Dial to
begintheCopyfunction.
COPY RUNTIME-00:15TO PROGRAM- 1BEGIN STATION- 9END STATION- 18[OK]
[OK]
8. Uponcompletionofthecopyfunction,
COPY FUNCTION:
[COPY PROGRAM]
theinitialCOPYFUNCTIONscreenwillbe
displayed. Repeat the procedure for additional [COPY RUNTIME]
programs as preferred.
44
CopyFunctions
RAIN MASTER TM EAGLE PLUS
Review Mode
The Review mode feature provides a convenient method of accessing all current
controller program structure information, as well as historical records of prior irrigation activity, flow rates and ET values and wireless communications activity.
The REVIEW menu options include direct Program setup parameters, historical
data logs for Irrigation activity, Alarm events, Flow rates, ET values, iCentral Communication protocol data and S/W (controller configuration).
Note: All information displayed on the Review screens is provided for reference and
evaluation only. No changes or deletions to programming, operating, configuration
or Alarm events can be made while the controller is in the Review mode.
Program Review
The Program review screens, accessible from both the PROGRAM and REVIEW
menus, access the following information for each irrigation program:
• Total program run time duration
• Program run time Adjust % factor
• Active watering day schedule
• Total assigned start times
• Total assigned station numbers
• Individual station run time assignment
• Cycle and Soak duration time (when applicable)
key to display the
1. PresstheREVIEW
PROGRAM:
REVIEWmenu.ThePROGRAMoptionischosen -MODIFY[REVIEW]
by default.
-COPY-
-NEW-DELETE-
2. PresstheDial toselect.TheREVIEWPROGRAM
screenisdisplayedwiththePROGRAMnumber
chosen. Press the Dial to select, then turn the
Dial to display the preferred program number.
Press the Dial to enter the selection.
REVIEW:
[PROGRAM]
-ALARM-IRRIGATION- -FLOW-COMM- -ET- -S/W-
3. PresstheNEXT
and Back
keys to
navigatethroughthesequenceofPROGRAM
REVIEWscreens.
REVIEW PROGRAM[ 1]
TOTAL STATIONS: 7
TOTAL RUNTIME:
2 HRS 24 MINUTES
Note: The PROGRAM number option is provided
on the top line of each review screen to access
information for any program as preferred.
Review Functions
45
RAIN MASTER TM EAGLE PLUS
Alarm Review
Thealarmeventarchivewillretainamaximumof220records.Allalarmevents
arestoredinchronologicalfirst-in,first-outorder.Whenthearchivereaches
capacity,theoldesteventrecorddropsoffasanewrecordenters.
1. PresstheREVIEW
key to display the
REVIEW:
[ALARM]
REVIEWmenu.ThePROGRAMoptionischosen -PROGRAM-IRRIGATION- -FLOWby default. Turn the DialtochooseALARM,
-COMM- -ET- -S/Wthen press the Dial to select.
2. Thealarmarchivescreenwillbedisplayed
01/02 FR 10:23:37AM
withasummarythelastAlarmevent.Press
STATION 147
DECODER NOT FOUND
the NEXT
and BACK
keys to navigate
through the sequence of review screens.
Communication Review Screens
Note: COMM review information (listed on four consecutive screens) provides comprehensive technical data pertaining to wireless communications configuration and
activity.
REVIEW:
1. PresstheREVIEW
key to display the
-PROGRAM-ALARMREVIEWmenu.ThePROGRAMoptionischosen -IRRIGATION- -FLOW[COMM] -ET- -S/Wby default. Turn the DialtochooseCOMM,
then press the Dial to select.
REVIEW COMM
2. PresstheNEXT
key to access the remaining S8901260580015370817
MDM S/N:50399736
review screen sequence.
[MORE]
Flow Review
TheFlowdataarchiveretainsupto12monthsofdatarecordsandcompiled
for review by month. The first of two review screens provides the selections for
monthanddisplayunits,withthetotalflowrepresentedforeachoftwoflowsensors.Thesecondscreendisplaysthesumtotalforbothflowsensors.
1. PresstheREVIEW
key to display the
REVIEWmenu.ThePROGRAMoptionischosen
by default. Turn the DialtochooseFLOW,then
press the Dial to enter the selection.
2. TheinitialREVIEWFLOWscreenisdisplayed
withflowdataforthecurrentmonth.To
change the month, press the Dial to select,
then turn the Dial to display the preferred
month. Press the Dial to enter the selection.
3. TousealternatedisplayUNITS,turntheDial
tochooseUNITS.PresstheDial to select, then
turn the Dial to display the preference. Press
the Dial to enter the selection.
46
ReviewFunctions
REVIEW:
-PROGRAM-ALARM-IRRIGATION- [FLOW]
-COMM- -ET- -S/WREVIEW FLOW:[JUN]
UNITS-GALLONS FLOW1=XXXXXXXX
FLOW2=XXXXXXXX
REVIEW FLOW:-JUNUNITS[GALLONS ]
FLOW1=XXXXXXXX
FLOW2=XXXXXXXX
RAIN MASTER TM EAGLE PLUS
4. Press the NEXT key access the second review
screen displaying the flow data total for both
sensors (if applicable). The same preference
options for MONTH and UNITS are provided.
REVIEW FLOW:[JUN]
UNITS-GALLONS TOTAL F1+F2=XXXXXXXX
Irrigation Review
A record of the last 25 automatic irrigation programs are stored in chronological
order with the latest event displayed first. When the archive reaches capacity, the
earliest event record is deleted as a new event is recorded.
key to display the
1. PresstheREVIEW
REVIEWmenu.ThePROGRAMoptionischosen
by default. Turn the Dial tochooseIRRIGATION,
then press the Dial to select.
2. Asummaryofthemostrecentoperationis
displayed. Press the NEXT
and BACK
keys to navigate through the review screens.
Configuration Review
key. Turn the Dial to
1. PresstheREVIEW
chooseS/W,thenpresstheDial to select.
Asummaryofthecurrentconfigurationis
provided.
REVIEW:
-PROGRAM-ALARM[IRRIGATION] -FLOW-COMM- -ET- -S/WPROGRAM 1 START
06/03 TH 01:45AM
END
06/03 TH 03:15AM
REVIEW:
-PROGRAM-ALARM-IRRIGATION- -FLOW-COMM- -ET- [S/W]
REVIEW CONFIGURATION
TYPE: CONVENTIONAL
FIRMWARE:V0.0.0
MAX STATION:48
ET Review
AllETdataprovidedtothecontrollerviatheInternetoraWeatherCenterII
weatherstationisretainedforarolling14-dayperiod.
TheETdatareceivedviatheInternet(HISTORIC)isdisplayedininchesandsent
to the controller at midnight of the current day. ET data received from the weatherstation(WXSTATION)isdisplayedasanumberofpulsesaccumulatedbythe
weather station since midnight.
key to display the
1. PresstheREVIEW
REVIEWmenu.ThePROGRAMoptionischosen
by default. Turn the Dial to choose ET, then
press the Dial to select.
REVIEW:
-PROGRAM-ALARM-IRRIGATION- -FLOW-COMM- [ET] -S/W-
2. PresstheDial to advance or press the BACK
key to retract the review screen sequence.
ET: SOURCE=HISTORIC
01/06 ET=.10
01/05 ET=.10
01/04 ET=.10[MORE]
ReviewFunctions
47
RAIN MASTER TM EAGLE PLUS
Manual Watering Operations
The Eagle Plus features a full complement of manual control options enabling
the irrigation system to be operated whenever and however supplemental
watering is preferred.
The manual control options enable you to operate the system by:
•STATION – Operate an individual station for a specified run time.
•PROGRAM – Operate specified watering program(s).
• MULTI-STATION – Operate up to six stations simultaneously for a specified run
time.
• TEST – Operate a specified group of stations in numeric sequence for a
specified run time.
Note: When stations or programs are selected for manual operation, the controller
determines if there is an association with the Master Valve and/or Pump output.
If an association exists with any selected station or program, the Master Valve and/
or Pump output will be activated during the manual operation. In Multi-Station
manual mode, the Master Valve and/or Pump output can be selected independently
as preferred.
Manual Station Operation
key to display the
1. PresstheMANUAL
MANUALOPERATIONSmenu screen. The
STATION option is selected by default.
MANUAL OPERATIONS:
[STATION] -PROGRAM-MULTI STATION-TEST-
2. PresstheDial to select. The STATION number
option is chosen by default. Press the Dial to
select, then turn the Dial to display the
preferred number. Press the Dial to select.
MANUAL OPERATIONS:
STATION- 1RUNTIME[01:25]
-START-
3. TurntheDial to choose the RUNTIME value.
Press the Dial to select, then turn the Dial to
displaythehourdigits(00–23).PresstheDial to
select, then turn the Dial to display the
minutesdigits(00–59).PresstheDial to enter
the selection.
4. TurntheDial to choose START, then press
the Dial to begin the manual operation.
The MANUALOPERATIONS status screen will
be displayed.
48
ManualStationOperation
MANUAL OPERATIONS:
STATION- 1RUNTIME[01:25]
-START-
MANUAL OPERATIONS:
STATION- 1RUNTIME-01:25[START]
RAIN MASTER TM EAGLE PLUS
5. Threemanualcontroloptionsareprovidedon STATION: 1 01:24:58
the statusscreen:
MVALVE:ON PUMP:OFF
[STOP]
•STOP- Toggles station operation OFF and ON.
-NEXT- -PREVIOUS •NEXT-Turnsoffthecurrentstation,resets
theruntime,andturnsonthenextstationin
numeric sequence.
•PREVIOUS-Turnsoffthecurrentstationandturnsonthepreviousstationin
numeric sequence.
Turn the Dial to choose the control option, then press the Dial to select.
key to return to the HOME screen.
6. Whenfinished,presstheHOME
Manual Program Operation
key to display the
1. PresstheMANUAL
MANUALOPERATIONSmenu screen.
The STATION option is selected by default.
MANUAL OPERATIONS:
[STATION] -PROGRAM-MULTI STATION-TEST-
2. TurntheDial right one step to choose
PROGRAM. Press the Dialtoselect.Thenext
MANUALOPERATIONS screen in sequence
will be displayed
MANUAL OPERATIONS:
-STATION- [PROGRAM]
-MULTI STATION-TEST-
3. ThePROGRAM number option is chosen by
default. Press the Dial to select, then turn
the Dial to display the preferred number.
Press the Dial to select.
MANUAL OPERATIONS:
PROGRAM[ 1]
-START-
4. TurntheDial to choose START, then press
the Dial to begin the manual operation.
The MANUALOPERATIONS status screen will
be displayed.
PROGRAM 1
STATION: 1 00:58:01
MVALVE:ON PUMP:OFF
[STOP]
Note: Selecting STOP displays a decision screen. Manual operation will not be
terminated unless the YES option is selected. Selecting YES will terminate any additional programs in the queue. Selecting NO steps back to the status screen.
5. Whenfinished,presstheHOME
return to the HOME screen.
key to
ARE YOU SURE YOU
WANT TO ABORT THE
CURRENT PROGRAMS?
[YES] -NO-
ManualProgramOperations
49
RAIN MASTER TM EAGLE PLUS
Manual Multi-Station Operation
key to display the
1. PresstheMANUAL
MANUALOPERATIONSmenu screen. The
STATION option is selected by default.
2. TurntheDial right two steps to choose
MULTI-STATION. Press the Dial to select.
Thenextscreeninsequencewillbedisplayed.
3. TheMANUALSTATION number is chosen by
default. Press the Dial to select, then turn the
Dial to display a STATIONnumber,MVorPMP
to be included in the operation. Press the Dial
to enter the selection.
4. Repeatthisproceduretoincludeuptofive
additional outputs. The selections are displayed
as they are entered.
MANUAL OPERATIONS:
[STATION] -PROGRAM-MULTI STATION-TESTMANUAL OPERATIONS:
-STATION- -PROGRAM[MULTI STATION]
-TESTMANUAL STATION:[ 1]
RUNTIME-00:00STATIONS:1
-START-
MANUAL STATION:[ 11]
RUNTIME-00:00STATIONS:1-3,6,9,11
-START-
Note: To clear the current station list, select CLR
MANUAL STATION:[CLR]
(located between PMP and 1) , then press the Dial RUNTIME-00:00STATIONS:NONE
to refresh the screen.
-START5. TurntheDial to choose the RUNTIME value.
Press the Dial to select, then turn the Dial to
displaythehourdigits(00–23).PresstheDial to
select, then turn the Dial to display the
minutesdigits(00–59).PresstheDial to enter
the selection.
6. TurntheDial to choose START, then press
the Dial to begin the manual operation.
The status screen will be displayed indicating the
station list and the remaining run time.
To terminate the operation, press the Dial to
selectSTOP.
Note: If flow sensing is operational, the indicated
total flow will be displayed in the status screen.
7. When finished, press the HOME
50
ManualMulti-StationOperation
MANUAL STATION:- 11RUNTIME[00:20]
STATIONS:1-3,6,9,11
-START-
MANUAL STATION:- 11RUNTIME-00:20STATIONS:1-3,6,9,11
[START]
STATIONS:1-3,6,9,11
00:20:07
FLOW=1747 GPM [STOP]
key to return to the HOME screen.
RAIN MASTER TM EAGLE PLUS
Manual Test Functions
The manual Test function enables a group of stations to be selected and
operated in numeric order for a specified run time.
key to display the
1. PresstheMANUAL
MANUALOPERATIONSmenu screen. The
STATION option is selected by default.
MANUAL OPERATIONS:
[STATION] -PROGRAM-MULTI STATION-TEST-
2. TurntheDial right three steps to choose TEST.
Press the Dial toselect.Thenextscreenin
sequence will be displayed.
MANUAL OPERATIONS:
-STATION- -PROGRAM-MULTI STATION[TEST]
3. Thebeginningstationnumberofthetestgroup MANUAL TEST OF
is chosen by default. Press the Dial to select, then STATION[ 9] TO- 48RUN TIME-01-MINS
turn the Dial to display the preferred station
-STARTnumber. Press the Dial to enter the selection.
4. TurntheDial to choose the group ending
MANUAL TEST OF
station number*. Press the Dial to select, then
STATION- 9- TO[ 18]
RUN TIME-01-MINS
turn the Dial to display the preferred station
-STARTnumber. Press the Dial to enter the selection.
*Note: The ending station number will be limited
to the controller station count configuration.
5. TurntheDialtochoosetheRUNTIMEvalue.
MANUAL TEST OF
Press the Dial to select, then turn the Dial to
STATION- 9- TO- 18RUN TIME[05]MINS
display the preferred run time duration from
-START01–59minutes.PresstheDial to enter the
selection.
6. TurntheDialtochooseSTART,thenpressthe
MANUAL TEST OF
Dial to begin the manual operation.
STATION- 9- TO[ 18]
RUN TIME-05-MINS
7. Three manual control options are provided on
[START]
the statusscreen:
•STOP- Toggles station operation OFF and ON.
STATION: 1 01:24:58
•NEXT-Turnsoffthecurrentstation,resets
MVALVE:ON PUMP:OFF
theruntime,andturnsonthenextstationin
[STOP]
numeric sequence.
-NEXT- -PREVIOUS •PREVIOUS-Turnsoffthecurrentstationand
turns on the previous station in numeric sequence.
Turn the Dial to choose the control option, then press the Dial to select.
key to return to the HOME screen.
8. Whenfinished,presstheHOME
ManualTestFunctions
51
RAIN MASTER TM EAGLE PLUS
Alarms Feature
The Alarms feature provides important, timely information regarding a condition
or event that requires user attention. Whenever one or more alarm conditions
occur, the Alarm LED indicator illuminates and is accompanied by a brief
description of the root cause. An optional “chirp” tone can be enabled that will
sound once every six seconds until the alarm notices have been cleared. Clearing
alarm notices is important since a pending alarm condition may affect future
automatic irrigation.
IMPORTANT: Depending on the cause of the alarm, clearing the alarm
notification does not necessarily resolve or eliminate the root cause.
Allalarmeventsarearchivedinaread-onlybufferastheyoccur.Thearchive
storesupto220Alarmeventsandcannotbeemptied.Alarmsarecompiledin
chronologicalorderwiththemostrecenteventdisplayedfirst.Oncethebufferis
full,theoldesteventdropsoffasanewoneenters.TheAlarmarchiveisaccessed
from REVIEW menu screen.
About Field Wire and Flow Alarms
Field Wire Fault Detection: The Eagle Plus can detect a short in the field wire
andinstantlyturnoffthatstation.Thecontrollerwillautomaticallyadvancefrom
thefaultystationtothenextprogrammedstationduringawateringcycle.
The display will report the fault condition any time a field wire fault occurs.
Additionally,theAlarmLEDindicatorwillilluminateandtheaudiblealert(when
enabled)willsounduntilallAlarmsarecleared.
Flow Detection: Whenoperatinginconjunctionwithoneortwosystemflow
sensors,thecontrollerwillprovidethefollowingwatchdogfunctions:
vUpondetectionofcatastrophic high-flow, the controller will trigger an alarm
andrespondautomaticallyasfollows:
wShutdownallactivestations.
wShutdownanormally-openmastervalve.
w Prohibit all program cycle starts until the alarm is cleared.
vUpondetectionofunscheduled flow, the controller will trigger an alarm and
respondautomaticallyasfollows:
wShutdownanormally-openmastervalve.
w Prohibit all program cycle starts until the alarm is cleared.
vUpondetectionofflowoutsidetheestablishedupper or lower flow limits, the
controllerwilltriggeranalarmandrespondautomaticallyasfollows:
wShutdownthedefectivestationandprohibititsoperationuntilthealarmis
cleared.
wAdvancetothenextstationintheprogramsequence.
52
AlarmsFeatureOverview
RAIN MASTER TM EAGLE PLUS
Clearing Alarms
ClearinganalarmnoticewillremoveitfromtheHOMEscreen,turnoffthealarm
LEDindicatorandsilencetheaudiblealerttone.Arecordofthealarmeventwillbe
stored in alarm archive until automatically deleted.
Note: The procedure for clearing alarms is slightly different if more than 10 alarm
conditions are indicated. Use the following procedures to clear alarms as applicable.
To clear 10 Alarms or less:
1. FromtheHomescreen,turntheDial to choose TU 07:56:14P WK1
VALID PGM:4
ALARMS,thenpresstheDial to select.
-MAIN- [ALARMS(
2)]
2. ThefirstAlarmconditionisdisplayed.Pressthe 06/03 TU 07:56:10PM
DialtocleartheAlarm.ThenextAlarmcondition SERVICE ESTABLISHED
will be displayed. Press the Dial to clear each
[CLEAR]
remainingAlarm.
To clear more than 10 Alarms:
1. FromtheHomescreen,turntheDial to choose TU 07:56:14P WK1
ALARMS,thenpresstheDial to select.
VALID PGM:4
-MAIN- [ALARMS( 12)]
2. ThefirstAlarmconditionisdisplayed.Pressthe 06/03 TU 07:56:10PM
DialtocleartheAlarm.
SERVICE ESTABLISHED
[CLEAR]
3. Thenextscreenprovidestheoptiontoclear
oneorallremainingAlarms.Toclearall
remainingAlarms,turntheDial to choose
CLEARALLALARMS,thenpresstheDial to
cleartheAlarms.
YOU HAVE 011 ACTIVE
ALARMS.
-CLEAR THIS ALARM[CLEAR ALL ALARMS]
ClearingAlarms
53
RAIN MASTER TM EAGLE PLUS
Analyzing Alarms
The table below represents a variety of alarm notices that may be encountered
for various controller input and output hardware configurations.
Flow Sensor
 Generic
1 – Power Restored
2 – Configuration Error
3 – Configuration Change
4 – MV Sensor Board Failure
5 – Program (#) Start Time Falls
Outside Water Window
6 – Electrical Short
7 – Wireless Service Disruption
8 – Output Board: (#) Failure
1 – Main Line Flow
2 – Station Flow (over)
3 – Station Flow (under)
4 – Unscheduled Flow
Rain/Weather Sensor
1 – Rain Sensor: Wet
2 – Hourly Rain Limit Exceeded
3 – Daily Rain Limit Exceeded
4 – Weather Station Out of Range
 Two-Wire Decoder
1 – Two-Wire Board Failure
2 – Two-Wire Field Wire Overcurrent
Detected
3 – Station (#) Decoder Not Found
4 – Station (#) Open Circuit At Solenoid
5 – Station (#) Short Circuit at Solenoid
6 – Station (#) Decoder Comm Error
7 – Two-Wire Decoder Programming
Failure
8 – Two-Wire Decoder Failure
Toassistinquicklylocatingaparticularcondition,thealarmsarecategorized
bycontrollerhardwareconfiguration.Usethelistednumberanddescriptionto
locate the specific condition and accompanying relevant information from the
followingexamples.
w Generic
1 – Power Restored
06/03 TU 07:56:14PM
POWER RESTORED
[CLEAR]
ThisAlarmoccurswheneverpowertothecontrollerhasbeenlostandrestored,
and is provided for reference only.
2 – Configuration Error
RAIN MASTER
EAGLE PLUS
CONFIGURATION ERROR
WWW.RAINMASTER.COM
This alarm notice occurs if the controller has failed to detect if the controller is
configuredforconventionaloutputoratwo-wiredecodersystem.
• Thecontrollerwillmakemultipleattemptstodetecttheoutputconfiguration.
• Ifavalidconfigurationisnotdetected,thecontrollerwillremaininoperable.
• ContactRainMastertechnicalserviceat1-800-777-1477.
54
AnalyzingAlarms–Generic
RAIN MASTER TM EAGLE PLUS
3 – Configuration Change
11/03 FR 11:32:05AM
MAX STATION IS: 48
MAX STATION WAS: 40
[CLEAR]
Thisalarmoccurseachtimeacontrollerconfigurationchangeisdetectedincluding:
• Achangeinthestationcountisdetectedsuchasadding/removinganoutput
board.
•4 – Master Valve, Pump or Sensor Error
11/03 SU 16:06:39
MV SENSOR BOARD
FAILURE EC=###
[CLEAR]
ThisAlarmindicatestheMasterValveboardhaseitherfailedorhasdatainitthat
isoutorrangeornon-existent.
Note: See Appendix C - Error Code Reference Chart on page 64 for additional EC
information. Contact Rain Master technical service at 1-800-777-1477.
5 – Program Start Time Falls Outside Water Window
10/19 FR 09:20:13AM
PROGRAM 05 STARTTIME
FALLS OUTSIDE WATER
WINDOW.
[CLEAR]
ThisAlarmindicatesthatastarttimeforaspecifiedprogramwillfalloutsidethe
established limits of the Water Window.
• ThecontrollerwillnotstartaprogramoutsideofWaterWindowandwill
terminate programs when the end of the Water Window is reached.
6 – Electrical Short
07/15 MO 10:00:00AM
STATION 26
ELECTRICAL SHORT
[CLEAR]
ThisAlarmindicatesashortcircuitorexcessivecurrentdrawhasbeendetected
on a specific station output.
• Thestationwillbeturnedoffandwillnotoperateinanysubsequentprogram
watering cycles until the alarm is cleared.
• Thenextprogrammedstationinsequencewillstart.
AnalyzingAlarms–Generic
55
RAIN MASTER TM EAGLE PLUS
7 – Wireless Service Disruption
01/23 SU 06:06:39AM
SERVICE ESTABLISHED
[CLEAR]
This alarm occurs whenever wireless service is established or re-established with
the network carrier.
• A counter is associated with this Alarm that determines how many times this
event must occur during the current day before the alarm is sent. The default
value is 1, with a maximum value of 100 (established in the iCentral).
Note: If the value is set to 100, this Alarm will never be sent to iCentral again.
8 – Output Board Failure
10/19 FR 03:30:05PM
OUTPUT BOARD:6
FAILURE EC=###
[CLEAR]
ThisAlarmindicatesthecontrollerhasdetectedanoutputboardfailurewhile
attempting to activate one or more station outputs on the board.
• Theoffendingoutputboardnumberisindicated.
Note: A two- or three-digit Failure EC code number is provided for use by customer
service personnel only.
wFlow Sensor Alarms
1 – Main Line Flow
05/18 SU 02:09:06PM
MAIN LINE
MEASURED=764 GPM
LIMIT:350 [CLEAR]
Thisalarmindicatesthemainlineflowhasexceededtheestablishedupperflow
limit.
Oncethecontrollerdetectsthisalarm:
• Allcurrentlyoperatingstationswillbeshutdown.
• Noirrigationprograms/stationswillirrigateuntilthisalarmiscleared.
Allnon-irrigationprogramsshallremainoperational.
• ShutsdownaNormally-OpenMasterValve.
56
AnalyzingAlarms–GenericandFlowSensor
RAIN MASTER TM EAGLE PLUS
2 –Station High-Flow
04/05 FR 22:19:26
STATION ### HI FLOW
MEASURED=364 GPM
LIMIT:346 [CLEAR]
This alarm indicates that
flow
Thisalarmindicatesthatastationflowhasexceededtheestablishedupperflow
limit.
Oncethecontrollerdetectsthiscondition:
• Thestationwillbeturnedoffandrestrictedfromrunninginanysubsequent
program watering cycles until the alarm is cleared.
• Thenextstationinsequenceassignedtotheprogramwilloperate.
3 – Station No-Flow
05/18 SU 02:09:15PM
STATION 169 NO FLOW
MEASURED=0 GPM
[CLEAR]
This
alarm indicates
flow that
Thisalarmindicatesastationflowthatislessthantheestablishedflowrange.
Oncethecontrollerdetectsthiscondition:
• Thestationwillbeturnedoff.
• Thenextstation(ifany)ofthisprogramwilloperated.
• Thestationwillberestrictedfromrunninginanysubsequentprogramwatering
cycles until the alarm is cleared.
4 – Unscheduled Flow
08/27 TH 11:47:13AM
UNSCHEDULED FLOW
MEASURED=36 GPM
LIMIT:32
[CLEAR]
Thisalarmindicatesthatflowinthemainlinehasbeendetectedatanunscheduled time.
Oncethecontrollerdetectsthisevent:
• Alloperatingprogramsareterminated.
• Noscheduledprogramswillstartuntilthisalarmiscleared.
• Thecontrollerwillnotgenerateaanotheralarmforthiseventuntilthecurrent
Alarmiscleared.
• ShutsdownaNormally-OpenMasterValve.
AnalyzingAlarms–FlowSensor
57
RAIN MASTER TM EAGLE PLUS
wRain Sensor or Weather Station Alarms
1 – Rain Sensor Status Change
02/07 SU 16:06:39PM
RAIN SENSOR:WET
[CLEAR]
ThisalarmoccurswhentherainsensorstatushaschangedfromDrytoWet,or
WettoDry.
• WhenaWETconditionisdetectedduringaprogramwateringcycle,theprogram will continue running, but all field outputs associated with the program
willbeturnedoff.
• Thecontrollerwillcontinuerunningallscheduledwateringprograms,butno
fieldoutputswillbeenergizedwhiletheWETconditionisdetected.
• IfthesensorstatuschangestoDRYwhiletheprogramisrunning,stationoutput will be reinstated enabling any current station operation to resume for the
duration of the remaining run time.
2 – Hourly Rain Limit Exceeded
12/24 TH 10:09:58AM
HOURLY RAIN LIMIT
EXCEEDED. 0.20 INCH
[CLEAR]
This alarm occurs when the weather station determines that the established
hourlyrainfalllimithasbeenexceeded.
• AllwateringprogramswillbesuspendeduntiltheRainHoldmodehasbeen
released.
• Thecontrollerwillnotgenerateanotheralarmforthiseventuntilthecurrent
alarm is cleared.
3 – Daily Rain Limit Exceeded
11/07 FR 11:00:46PM
DAILY RAIN LIMIT
EXCEEDED, 0.50 INCH
[CLEAR]
This alarm occurs when the weather station determines that the established
dailyrainfalllimithasbeenexceeded.
• AllwateringprogramswillbesuspendeduntiltheRainHoldmodehasbeen
released.
• Thecontrollerwillnotgenerateanotheralarmforthiseventuntilthecurrent
alarm is cleared.
58
AnalyzingAlarms–Rain/WeatherSensor
RAIN MASTER TM EAGLE PLUS
4 – Weather Station Out of Range
10/13 FR 04:30:05AM
WX STATION OUT OF
RANGE ET=.50
[CLEAR]
ThisalarmindicatestheWeatherStationisreportingthemaximumETratehas
beenexceededandattentionisrequired.
• ThisAlarm condition will not be reported more than once per day.
• Themaximumvaluereportedfromaweatherstationis0.50maximum.
• TheAlarmeventoccursiftheweatherstationreadsmorethanthemaximum
50rateofpulsesper24-hourperiod.
• ThehistoricETvalueforthecurrentmonthwillbeusedforETcomputationin
lieu of the indicated value.
wTwo-Wire Decoder System Alarms
1 – Two-Wire Board Failure
03/09 FR 13:30:05
TWO WIRE BOARD
FAILURE EC=###
[CLEAR]
ThisalarmindicatesanerrorhasoccurredpertainingtotheTwo-WireDecoder
output board.
Note: See Appendix C - Error Code Reference Chart on page 64 for additional EC information. Contact Rain Master technical service at 1-800-777-1477.
2 – Two-Wire Field Wiring Over-current Detected
07/15 MO 10:00:35AM
TWO WIRE FIELD
WIRING OVERCURRENT
DETECTED. [CLEAR]
This alarm indicates higher than normal current load is detected on the decoder
communication/powertwo-wirecable.
• Allstationswillbeturnedoff.
• Allsubsequentwateringprogramswillbecanceled.
Note: Wait two minutes before clearing alarm and retrying the two-wire system.
AnalyzingAlarms–Two-WireDecoderSystem
59
RAIN MASTER TM EAGLE PLUS
3 – Station (#) Decoder Not Found
07/15 MO 10:00:21AM
STATION 153
DECODER NOT FOUND
[CLEAR]
This alarm event occurs if the controller attempts to operate a decoder station
numberthateitherdoesnotexistorisnotrecognizedbythecontroller.
• ThisalarmoccursexclusivelyduringTestmodeoperations.
4 – Station (#) Open Circuit at Solenoid
07/15 MO 10:00:00AM
STATION 109
OPEN CIRCUIT AT
SOLENOID
[CLEAR]
Thisalarmindicatesanopen-circuitconditionexistsonthespecifieddecoderstation solenoid connection.
• Thestationwillbeturnedoff,andthenextstationinsequencewillstart.
• Thecontrollerwillnotattempttooperatethestationuntilthealarmiscleared.
5 – Station (#) Short Circuit at Solenoid
07/15 MO 10:00:05AM
STATION 109
SHORT CIRCUIT AT
SOLENOID
[CLEAR]
Thisalarmindicatesashort-circuitconditionexistsonthespecifieddecoderstation solenoid connection.
• Thestationwillbeturnedoff,andthenextstationinsequencewillstart.
• Thecontrollerwillnotattempttooperatethestationuntilthealarmiscleared.
6 – Station (#) Decoder Comm Error
07/15 MO 10:02:25AM
STATION 99
DECODER COMM ERROR
[CLEAR]
This alarm indicates the controller cannot communicate successfully with the
specified decoder station.
• Thealarmwillbereportedeachtimethecontrollerattemptstooperatethestation.
• ThisalarmconditionisnotindicatedduringTestmodeoperations.
60
AnalyzingAlarms–Two-WireDecoderSystem
RAIN MASTER TM EAGLE PLUS
7 – Station (#) Decoder Programming Failure
07/15 MO 10:04:13AM
TWO-WIRE DECODER
PROGRAMMING FAILURE
[CLEAR]
This alarm is recorded during the decoder programming process indicating an
error occurred, preventing the decoder from being successfully programmed.
• Thealarmwillbereportedeachtimeprogrammingthedecoderisattempted.
8 – Station (#) Decoder Failure
07/15 MO 10:07:08AM
TWO-WIRE DECODER
FAILURE EC=###
[CLEAR]
Thisalarmindicatesthetwo-wiredecodersystemisinoperable.
• Thealarmwillbereportedeachtimeprogrammingthedecoderisattempted.
Note: See Appendix C - Error Code Reference Chart on page 64 for additional EC information. Contact Rain Master technical service at 1-800-777-1477.
AnalyzingAlarms–Two-WireDecoderSystem
61
RAIN MASTER TM EAGLE PLUS
Appendix A - General Specifications
Cabinet Dimensions:
•WallMount:11”Wx16”Hx5.625”D(27,9cmWx40,6cmHx14,29cmD)
•PedestalMount:
PSB:16.5”Wx38”Hx17.25”D(41,9cmWx96,5cmHx43,8cmD)
SPED:16”Wx34”Hx16”D(40,6cmWx86,4cmHx40,6cmD)
Temperature Range:
•Operating:+14°Fto+140°F(-10°Cto+60°C)
•Storage:-22°Fto+149°F(-30°Cto+65°C).
Power Specifications:
•InternalTransformer,Class2,ULListed,CSACertified(orequivalent)
Input:120VAC±10%,50/60Hz
Output:24VAC±10%,50/60Hz
•MaximumLoadPerStation:0.5A@24VAC@77°(25°C)
•MaximumLoadPerMasterValve:0.5A@24VAC@77°F(25°C)
•MaximumLoadPerPumpOutput:0.5A@24VAC@77°F(25°C)
•TotalMaximumLoad:1.5A@24VAC.
Output Surge Protection(excluding2-wiredecodermodels):
6KVcommon,1KVnormal.
Controller Memory:
TheEaglePlusutilizesNVRAM(Non-volatileRandomAccessMemory)
technologytoprotectalluser-definedprogramandsetupdatafromlossin
the event of a power failure. Time and date settings will be maintained without
powerforapproximately30days.
62
AppendixA–GeneralSpecifications
RAIN MASTER TM EAGLE PLUS
Appendix B - Flow Sensor Specifications
TheEaglePluscontrollersupportsthecompletelineofIrritrolflowsensormodels
listed in the following tables.
PVC Sensor Body Material
FS-150
Sensor Model #
Pipe Size
1½”
Operating Range 5-100 GPM
Max. Water Press.* 100 psi
K-Value
457
Offset Value
0
Connection Type
Slip
FS-200
FS-300
FS-400
2”
3”
4”
10-200 GPM 20-300 GPM 40-500 GPM
100 psi
100 psi
100 psi
776
2268
3752
104
483
834
Slip
Slip
Slip
*Maximum water pressure @ 68° F (20°C).
Bronze Sensor Body Material
Sensor Model #
Pipe Size
Operating Range
Max. Water Press.
K-Value
Offset Value
Connection Type
FS-8100
FS-8125
FS-8150
FS-8200
FS-8250
1”
1¼”
1½”
2”
2½”
2-40 GPM
3-60 GPM 4-80 GPM 10-100 GPM 16-160 GPM
400 psi
400 psi
400 psi
200 psi
200 psi
109
209
291
750
1021
27
32
24
0
370
NPT Female NPT Female NPT Female NPT Female* NPT Female
*Includes copper male adapter.
Note: In addition to the standard models listed above, an impeller-type flow sensor
adapter, Model # FS-INSERT-B, is available to accommodate pipe sizes from 3 to 40”
(7.6 to 102cm). Requires pipe saddle with 2” female NPT inlet.
AppendixB–FlowSensorSpecifications
63
RAIN MASTER TM EAGLE PLUS
Appendix C -Error Code Reference Chart
ThechartbelowprovidesacrossreferenceofECerrorcodenumbers,includedin
various alarm screens, to the root cause of the alarm. This information is primarily
used for system troubleshooting to help Rain Master service personnel quickly
identify and resolve most controller operating issues that may be encountered.
2-Wire Base Error Codes
EC #
Cause
2-Wire Decoder Error Codes
EC #
Cause
2. . . . . . . . .
4. . . . . . . . .
5. . . . . . . . .
6. . . . . . . . .
8. . . . . . . . .
11 . . . . . . . .
12 . . . . . . . .
15 . . . . . . . .
16 . . . . . . . .
223 . . . . . . . .
224 . . . . . . . .
230 . . . . . . . .
231 . . . . . . . .
3 ........
7 ........
64 . . . . . . . .
65 . . . . . . . .
66 . . . . . . . .
67 . . . . . . . .
68 . . . . . . . .
69 . . . . . . . .
70 . . . . . . . .
71 . . . . . . . .
72 . . . . . . . .
73 . . . . . . . .
74 . . . . . . . .
75 . . . . . . . .
76 . . . . . . . .
77 . . . . . . . .
78 . . . . . . . .
220 . . . . . . . .
221 . . . . . . . .
222 . . . . . . . .
232 . . . . . . . .
233 . . . . . . . .
234 . . . . . . . .
OVER CURRENT
I2C ERROR
ILLEGAL COMMAND
COMMAND REJECTED
MORE DATA READY
FRAME ERROR
TWO WIRE MODE FAULT
UNIT BUSY
REMOTE LOGIN
CHKSUM CALC ERROR
ADDRESS ERROR
UNIT EXISTS
COMM ERROR
2-Wire Bridge Error Codes
EC #
Cause
9. . . . . . . . . .
10 . . . . . . . . .
13 . . . . . . . . .
14. . . . . . . . .
SLOW POWERUP
OVER CURRENT
CHECKSUM
NO RESPONSE
MV Sensor Board Error Codes
EC #
Cause
40
41
42
43
44
45
46
47
64
........
........
........
........
........
........
........
........
SHORT
ET
READ ET
RAIN
TRIAC
FLOW1
FLOW2
MV/PUMP
AppendixC–ErrorCodeReferenceChart
NO RESPONSE
CHECKSUM ERROR
OVER CURRENT
SHORT CIRCUIT
OPEN CIRCUIT
I2C ERROR
ILLEGAL COMMAND
COMMAND REJECTED
PARTIAL READING
FRAMING ERROR
LIMIT EXCEEDED
PORTS EXCEEDED
LOW STARTUP VOLTAGE
DATA READY
BELOW LOWER LIMIT
DATA OVERFLOW
NO AC VOLTAGE
QTY SENT ERROR
QTY RECEIVED ERROR
CHKSUM CALC ERROR
FOUND
NOT FOUND
PROG ERROR
Output Board Error Codes
EC #
Cause
4 . . . . . . . . . COMMUNICATION ERROR
255. . . . . . . . . LOST COMMUNICATION
EC #
iCentral Error Codes
Cause
100. . . . . . . . . COMMUNICATION ERROR
RAIN MASTER TM EAGLE PLUS
Appendix D - FCC Rules - Electromagnetic Compatibility
This equipment generates and uses radio frequency energy and if not installed and
used properly, that is, in strict accordance with the manufacturer’s instructions, may
cause interference to radio and television reception. It has been type tested and
foundtocomplywiththelimitsforaFCCClassBcomputingdeviceinaccordance
withthespecificationsinSubpartJofPart15ofFCCRules,whicharedesignedto
provide reasonable protection against such interference in a residential installation.
However,thereisnoguaranteethatinterferencewillnotoccurinaparticular
installation. If this equipment does cause interference to radio or television
reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following
measures:
• Reorientthereceivingantenna.
• Relocatetheirrigationcontrollerwithrespecttothereceiver.
• Movetheirrigationcontrollerawayfromthereceiver.
• Plugtheirrigationcontrollerintoadifferentoutletsotheirrigationcontroller
and receiver are on different branch circuits.
Ifnecessary,theusershouldconsultthedealeroranexperiencedradio/television
technician for additional suggestions. The user may find the following booklet
preparedbytheFederalCommunicationsCommissionhelpful:
“HowtoIdentifyandResolveRadio-TVInterferenceProblems”.Thisbookletis
availablefromtheU.S.GovernmentPrintingOffice,Washington,DC20402.Stock
No.004-000-00345-4.
AppendixD–FCCRules-ElectromagneticCompatibility
65
RAIN MASTER TM EAGLE PLUS
Notes:
66
NotesPage
RAIN MASTER TM EAGLE PLUS
Notes:
NotesPage
67
www.irritrol.com•www.rainmaster.com
©2013Irritrol
FormNumber373-0550Rev.C