EEDDE08-204
technical data
FXAQ-MAVE
air conditioning systems
Wall Mounted Unit
2e
• Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE
TABLE OF CONTENTS
FXAQ-MAVE
1
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
3
2
Safety device settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4
Control systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5
Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Cooling capacity tables
Heating capacity tables
6
.............................................. 6
.............................................. 8
Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . 10
Dimensional drawing
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
7
Piping diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
8
Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Wiring diagram
9
10
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16
Service space
• VRV® Systems • Indoor Units
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1
• Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE
1
e t t i n s umUE oVe AMtr M so - lyo Q SdlVA nRaX WFVI
1-1
Specifications
TECHNICAL SPECIFICATIONS
FXAQ20MAVE
FXAQ25MAVE
FXAQ32MAVE
FXAQ40MAVE
FXAQ50MAVE
FXAQ63MAVE
7.10
Nominal
Capacity
Cooling
kW
2.20
2.80
3.60
4.50
5.60
Heating
kW
2.50
3.20
4.00
5.00
6.30
8.00
Power input
(Nominal)
Cooling
kW
0.016
0.022
0.027
0.020
0.027
0.050
Heating
kW
0.024
0.027
0.032
0.020
0.032
0.060
Casing
Colour
Dimensions
Unit
Weight
Unit
Heat
Exchanger
Dimensions
white (3.0Y8.5/0.5)
Height
mm
290
290
290
290
290
290
Width
mm
795
795
795
1050
1050
1050
Depth
mm
230
230
230
230
230
230
kg
11
11
11
14
14
14
2
2
2
2
2
2
Nr of Rows
Fin Pitch
mm
1.40
1.40
1.40
1.40
1.40
1.40
Face
Area
m²
0.161
0.161
0.161
0.213
0.213
0.213
14
14
14
14
14
14
Nr of Stages
Fan
Type
Cross flow fan
Quantity
Air Flow Rate
Fan
Cooling
Motor
1
1
1
1
High
m³/min
7.50
8.00
9.00
12.00
15.00
19.00
Low
m³/min
4.50
5.00
5.50
9.00
12.00
14.00
Quantity
Model
Output
(high)
W
1
1
1
1
1
1
QCL9661M
QCL9661M
QCL9661M
QCL9686M
QCL9686M
QCL9686M
40
40
40
43
43
43
Drive
Refrigerant
Name
Cooling
Sound
Pressure
Piping
connections
Liquid (OD)
Direct drive
R-410A
High
dBA
35.0
36.0
37.0
39.0
42.0
46.0
Low
dBA
29.0
29.0
29.0
34.0
36.0
39.0
mm
6.4
6.4
6.4
6.35
9.5
Type
Flare connection
Diameter
Gas
Drain
Type
Diameter
mm
12.7
12.7
12.7
12.7
12.7
15.9
Diameter
mm
18
18
18
18
18
18
Heat Insulation
Foamed polystyrene/polyethylene
Air Filter
Washable resin net
Refrigerant control
Electronic expansion valve
Temperature control
Microprocessor thermostat for cooling and heating
Safety devices
Standard
Accessories
6.4
Flare connection
PC board fuse
Standard Accessories
Installation and operation manual
Installation panel
Paper pattern for installation
Insulation tape
Clamps
Screws
Notes
Nominal cooling capacities are based on : indoor temperature : 27° CDB, 19° CWB, outdoor temperature : 35° CDB,
equivalent refrigerant piping : 5m (horizontal)
Nominal heating capacities are based on : indoor temperature : 20° CDB, outdoor temperature : 7° CDB, 6° CWB,
equivalent refrigerant piping : 5m (horizontal)
Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
2
• VRV® Systems • Indoor Units
• Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE
1
1-2
Specifications
ELECTRICAL SPECIFICATIONS
Power Supply
Voltage range
Notes
FXAQ25MAVE
FXAQ32MAVE
1
1
1
1
1
1
50
50
50
50
50
50
Name
FXAQ40MAVE
FXAQ50MAVE
FXAQ63MAVE
VE
Phase
Current
FXAQ20MAVE
Frequency
Hz
Voltage
V
Minimum circuit amps
(MCA)
A
0.30
0.40
0.40
0.40
0.40
0.60
Maximum fuse amps (MFA) A
15.00
15.00
15.00
15.00
15.00
15.00
Full load amps (FLA)
A
0.20
0.30
0.30
0.30
0.30
0.50
Minimum
V
Maximum
V
220-240
-10%
+10%
Voltage range : units are suitable for use on electrical systems where voltage supplied to unit terminals is not below
or above listed range limits.
Maximum allowable voltage range variation between phases is 2%.
MCA/MFA : MCA = 1.25 x FLA
MFA<= 4 x FLA
next lower standard fuse rating minimum 15A
select wire size based on the MCA
instead of a fuse, use a circuit breaker
For more details concerning conditional connections, see http://extranet.daikineurope.com, select "E-Data Books”.
Finally, click on the document title of your choice.
21
• VRV® Systems • Indoor Units
3
• Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE
2
Safety device settings
FXAQ20MA
FXAQ25MA
PC BOARD FUSE
FXAQ32MA
FXAQ40MA
FXAQ50MA
FXAQ63MA
250V 3A
4D034906F
3
Options
FXAQ20MA
DRAIN PUMP KIT
FXAQ25MA
FXAQ32MA
FXAQ40MA
FXAQ50MA
FXAQ63MA
K-KDU572CVE
ED39-226B
4
• VRV® Systems • Indoor Units
• Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE
4
Control systems
Individual control systems
WIRED REMOTE CONTROL
INFRARED REMOTE CONTROL
FXAQ20MA
FXAQ25MA
FXAQ32MA
FXAQ40MA
BRC1D52
BRC7E618
BRC7E619
FXAQ50MA
FXAQ63MA
FXAQ20MA
FXAQ25MA
FXAQ32MA
FXAQ40MA
DCS302C51
DCS301B51
DST301B51
FXAQ50MA
FXAQ63MA
FXAQ20MA
FXAQ25MA
FXAQ32MA
FXAQ40MA
KRP2A51#
KRP4A51#
KRP4A93
KRCS01-1
KJB311A
KJB212A
FXAQ50MA
FXAQ63MA
Heat pump
Cooling only
Centralised control systems
CENTRALISED REMOTE CONTROL
UNIFIED ON/OFF CONTROL
SCHEDULE TIMER
Others
WIRING ADAPTER FOR ELECTRICAL APPENDICES (1)
WIRING ADAPTER FOR ELECTRICAL APPENDICES (2)
INSTALLATION BOX FOR ADAPTER PCB (2) (3)
REMOTE SENSOR
ELECTRICAL BOX WITH EARTH TERMINAL (3 BLOCKS)
ELECTRICAL BOX WITH EARTH TERMINAL (2 BLOCKS)
NOISE FILTER (FOR ELECTROMAGNETIC INTERFACE USE ONLY)
EXTERNAL CONTROL ADAPTER FOR OUTDOOR UNITS (INSTALLATION ON INDOOR UNIT)
KEK26-1A
DTA104A61#
PCV0320
NOTES
1
Installation box is necessary for each adapter marked with #.
2
Up to 2 adapters can be fixed per installation box.
3
Only 1 installation box can be installed per indoor unit.
• VRV® Systems • Indoor Units
5
• Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE
5
Capacity tables
5-1
Cooling capacity tables
FXAQ-MA
TC: Total capacity;kW – SHC: Sensible capacity;kW
6
Unit size
Nominal
capacity
20
2.2
25
2.8
32
3.6
40
4.5
Outdoor
air temp.
°CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
14.0WB
20.0DB
TC
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
16.0WB
23.0DB
SHC
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
TC
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
18.0WB
26.0DB
SHC
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
TC
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
SHC
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
• VRV® Systems • Indoor Units
Indoor air temperature
19.0WB
27.0DB
TC
SHC
2.2
1.9
2.2
1.9
2.2
1.9
2.2
1.9
2.2
1.9
2.2
1.9
2.2
1.9
2.2
1.9
2.2
1.9
2.2
1.9
2.2
1.9
2.2
1.9
2.2
1.9
2.2
1.9
2.2
1.9
2.2
1.9
2.8
2.2
2.8
2.2
2.8
2.2
2.8
2.2
2.8
2.2
2.8
2.2
2.8
2.2
2.8
2.2
2.8
2.2
2.8
2.2
2.8
2.2
2.8
2.2
2.8
2.2
2.8
2.2
2.8
2.2
2.8
2.2
3.6
2.7
3.6
2.7
3.6
2.7
3.6
2.7
3.6
2.7
3.6
2.7
3.6
2.7
3.6
2.7
3.6
2.7
3.6
2.7
3.6
2.7
3.6
2.7
3.6
2.7
3.6
2.7
3.6
2.7
3.6
2.7
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
20.0WB
28.0DB
TC
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.2
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
2.9
2.9
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.7
3.7
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.7
4.7
4.6
22.0WB
30.0DB
SHC
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.6
2.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.5
3.5
TC
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.5
2.5
2.4
2.4
2.4
2.3
2.3
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.3
3.3
3.2
3.2
3.1
3.1
3.0
3.0
2.9
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.2
4.2
4.1
4.1
4.0
3.9
3.9
3.8
3.8
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.3
5.2
5.2
5.1
5.0
4.9
4.9
4.8
4.7
24.0WB
32.0DB
SHC
2.0
2.0
2.0
2.0
2.0
2.0
2.0
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.8
1.8
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.2
2.2
2.2
2.2
2.2
2.2
2.1
2.1
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.7
2.7
2.7
2.6
2.6
2.6
2.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.5
3.5
3.4
3.4
3.4
3.3
3.3
TC
2.9
2.9
2.8
2.8
2.7
2.7
2.7
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.3
3.7
3.6
3.6
3.5
3.5
3.4
3.4
3.4
3.3
3.3
3.2
3.2
3.1
3.1
3.0
3.0
4.7
4.7
4.6
4.6
4.5
4.4
4.4
4.3
4.3
4.2
4.2
4.1
4.0
4.0
3.9
3.8
5.9
5.8
5.8
5.7
5.6
5.5
5.5
5.4
5.3
5.3
5.2
5.1
5.0
5.0
4.9
4.8
SHC
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.8
1.8
1.8
1.8
1.8
1.7
1.7
2.3
2.2
2.3
2.2
2.2
2.2
2.2
2.2
2.2
2.1
2.1
2.1
2.1
2.1
2.0
2.0
2.8
2.8
2.8
2.8
2.7
2.7
2.7
2.7
2.6
2.6
2.6
2.6
2.5
2.5
2.5
2.5
3.6
3.5
3.5
3.5
3.4
3.4
3.4
3.3
3.3
3.3
3.2
3.2
3.1
3.1
3.1
3.0
• Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE
5
Capacity tables
5-1
Cooling capacity tables
FXAQ-MA
TC: Total capacity;kW – SHC: Sensible capacity;kW
Unit size
Nominal
capacity
50
5.6
63
7.1
Outdoor
air temp.
°CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
14.0WB
20.0DB
TC
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
16.0WB
23.0DB
SHC
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
TC
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
18.0WB
26.0DB
SHC
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
TC
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
SHC
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
• VRV® Systems • Indoor Units
Indoor air temperature
19.0WB
27.0DB
TC
SHC
5.6
4.2
5.6
4.2
5.6
4.2
5.6
4.2
5.6
4.2
5.6
4.2
5.6
4.2
5.6
4.2
5.6
4.2
5.6
4.2
5.6
4.2
5.6
4.2
5.6
4.2
5.6
4.2
5.6
4.2
5.6
4.2
7.1
5.3
7.1
5.3
7.1
5.3
7.1
5.3
7.1
5.3
7.1
5.3
7.1
5.3
7.1
5.3
7.1
5.3
7.1
5.3
7.1
5.3
7.1
5.3
7.1
5.3
7.1
5.3
7.1
5.3
7.1
5.3
20.0WB
28.0DB
TC
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
5.9
5.8
5.7
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.5
7.4
7.2
22.0WB
30.0DB
SHC
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.2
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.3
5.3
TC
6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.6
6.5
6.4
6.3
6.2
6.1
6.0
5.9
5.8
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.4
8.3
8.1
8.0
7.9
7.8
7.7
7.5
7.4
24.0WB
32.0DB
SHC
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.3
4.3
4.2
4.2
4.2
4.1
4.1
4.0
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.5
5.5
5.4
5.4
5.3
5.2
5.2
5.1
5.1
TC
7.4
7.3
7.2
7.1
7.0
6.9
6.8
6.7
6.6
6.6
6.5
6.4
6.3
6.2
6.1
6.0
9.3
9.2
9.1
9.0
8.8
8.7
8.7
8.5
8.4
8.3
8.2
8.1
7.9
7.8
7.7
7.6
SHC
4.4
4.3
4.3
4.3
4.2
4.2
4.2
4.1
4.1
4.0
4.0
3.9
3.9
3.8
3.8
3.8
5.3
5.3
5.2
5.2
5.2
5.1
5.1
5.0
5.0
4.9
4.9
4.8
4.8
4.7
4.7
4.6
7
• Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE
5
Capacity tables
5-2
Heating capacity tables
FXAQ-MA
8
Unit Size
Nominal capacity
20
2.5
25
3.2
32
4.0
40
5.0
°CDB
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
Outdoor
air temperature
°CWB
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7
16.0
kW
1.5
1.5
1.6
1.7
1.8
1.9
1.9
2.0
2.0
2.1
2.2
2.3
2.5
2.5
2.6
2.7
2.8
2.8
2.8
1.9
1.9
2.1
2.2
2.3
2.4
2.5
2.5
2.6
2.7
2.8
3.0
3.1
3.3
3.4
3.5
3.6
3.6
3.6
2.4
2.4
2.6
2.7
2.9
3.0
3.1
3.1
3.2
3.4
3.5
3.7
3.9
4.1
4.2
4.3
4.5
4.5
4.5
3.0
3.0
3.2
3.4
3.6
3.7
3.8
3.9
4.0
4.2
4.4
4.7
4.9
5.1
5.2
5.4
5.6
5.6
5.6
• VRV® Systems • Indoor Units
18.0
kW
1.5
1.5
1.6
1.7
1.8
1.9
1.9
2.0
2.0
2.1
2.2
2.3
2.5
2.5
2.6
2.7
2.7
2.7
2.7
1.9
1.9
2.1
2.2
2.3
2.4
2.4
2.5
2.6
2.7
2.8
3.0
3.1
3.2
3.4
3.4
3.4
3.4
3.4
2.4
2.4
2.6
2.7
2.8
3.0
3.1
3.1
3.2
3.4
3.5
3.7
3.9
4.1
4.2
4.3
4.3
4.3
4.3
2.9
3.0
3.2
3.4
3.6
3.7
3.8
3.9
4.0
4.2
4.4
4.6
4.9
5.1
5.2
5.3
5.3
5.3
5.3
Indoor air temperature °CDB
20.0
21.0
kW
kW
1.5
1.5
1.5
1.5
1.6
1.6
1.7
1.7
1.8
1.8
1.9
1.9
1.9
1.9
1.9
1.9
2.0
2.0
2.1
2.1
2.2
2.2
2.3
2.3
2.4
2.4
2.5
2.4
2.5
2.4
2.5
2.4
2.5
2.4
2.5
2.4
2.5
2.4
1.9
1.9
1.9
1.9
2.0
2.0
2.2
2.2
2.3
2.3
2.4
2.4
2.4
2.4
2.5
2.5
2.6
2.6
2.7
2.7
2.8
2.8
3.0
3.0
3.1
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
2.3
2.3
2.4
2.4
2.6
2.6
2.7
2.7
2.8
2.8
3.0
3.0
3.1
3.1
3.1
3.1
3.2
3.2
3.4
3.4
3.5
3.5
3.7
3.7
3.9
3.9
4.0
3.9
4.0
3.9
4.0
3.9
4.0
3.9
4.0
3.9
4.0
3.9
2.9
2.9
3.0
3.0
3.2
3.2
3.4
3.4
3.6
3.5
3.7
3.7
3.8
3.8
3.9
3.9
4.0
4.0
4.2
4.2
4.4
4.4
4.6
4.6
4.9
4.8
5.0
4.8
5.0
4.8
5.0
4.8
5.0
4.8
5.0
4.8
5.0
4.8
22.0
kW
1.5
1.5
1.6
1.7
1.8
1.9
1.9
1.9
2.0
2.1
2.2
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
1.9
1.9
2.0
2.2
2.3
2.4
2.4
2.5
2.6
2.7
2.8
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
2.3
2.4
2.6
2.7
2.8
3.0
3.0
3.1
3.2
3.4
3.5
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
2.9
3.0
3.2
3.4
3.5
3.7
3.8
3.9
4.0
4.2
4.4
4.6
4.7
4.7
4.7
4.7
4.7
4.7
4.7
24.0
kW
1.5
1.5
1.6
1.7
1.8
1.9
1.9
1.9
2.0
2.1
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
1.9
1.9
2.0
2.1
2.3
2.4
2.4
2.5
2.6
2.7
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.3
2.4
2.5
2.7
2.8
3.0
3.0
3.1
3.2
3.4
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
2.9
3.0
3.2
3.4
3.5
3.7
3.8
3.9
4.0
4.2
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
• Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE
5
Capacity tables
5-2
Heating capacity tables
FXAQ-MA
Unit Size
Nominal capacity
50
6.3
63
8.0
°CDB
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
Outdoor
air temperature
°CWB
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7
16.0
kW
3.7
3.8
4.1
4.3
4.5
4.7
4.8
4.9
5.1
5.3
5.5
5.9
6.2
6.4
6.6
6.8
7.0
7.1
7.1
4.7
4.9
5.1
5.4
5.7
6.0
6.1
6.3
6.5
6.8
7.0
7.5
7.9
8.1
8.4
8.7
8.9
9.0
9.0
• VRV® Systems • Indoor Units
18.0
kW
3.7
3.8
4.0
4.3
4.5
4.7
4.8
4.9
5.1
5.3
5.5
5.9
6.2
6.4
6.6
6.7
6.7
6.7
6.7
4.7
4.9
5.1
5.4
5.7
6.0
6.1
6.3
6.5
6.7
7.0
7.4
7.8
8.1
8.4
8.5
8.5
8.5
8.5
Indoor air temperature °CDB
20.0
21.0
kW
kW
3.7
3.7
3.8
3.8
4.0
4.0
4.3
4.2
4.5
4.5
4.7
4.7
4.8
4.8
4.9
4.9
5.1
5.1
5.3
5.3
5.5
5.5
5.8
5.8
6.2
6.1
6.3
6.1
6.3
6.1
6.3
6.1
6.3
6.1
6.3
6.1
6.3
6.1
4.7
4.7
4.8
4.8
5.1
5.1
5.4
5.4
5.7
5.7
6.0
6.0
6.1
6.1
6.2
6.2
6.4
6.4
6.7
6.7
7.0
7.0
7.4
7.4
7.8
7.7
8.0
7.7
8.0
7.7
8.0
7.7
8.0
7.7
8.0
7.7
8.0
7.7
22.0
kW
3.7
3.8
4.0
4.2
4.5
4.7
4.8
4.9
5.1
5.3
5.5
5.8
5.9
5.9
5.9
5.9
5.9
5.9
5.9
4.7
4.8
5.1
5.4
5.7
6.0
6.1
6.2
6.4
6.7
7.0
7.4
7.5
7.5
7.5
7.5
7.5
7.5
7.5
24.0
kW
3.7
3.8
4.0
4.2
4.5
4.7
4.8
4.9
5.1
5.3
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
4.7
4.8
5.1
5.4
5.7
5.9
6.1
6.2
6.4
6.7
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
9
• Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE
6
Dimensional drawing & centre of gravity
6-1
Dimensional drawing
FXAQ20,25,32MA
90 or more
(required space)
Piping direction
Nr
1
2
3
4
5
6
7
8
9
30 or more
(required space)
290
Approx. 400
232
230
Dimensions for
full open front panel
Piping direction
14.5
50 or more
(Required space)
Name plate Note 2
795
Piping direction
50 or more
(Required space)
626
107
Outside line
120 or less
62
Approx. 475
Approx. 460
Description
ø 12.7 Flare connection
ø 6.4 Flare connection
VP13 (External dia. ø18)
M4
105
155
(Filter part)
2500 or more
For installation
in high places
Part name
Front panel
Front grill
Air outlet
Gas pipe
Liquid pipe
Drain hose
Grounding terminal
Right side pipe connection hole
Left side pipe connection hole
60
Approx. 415
NOTES
44
Approx. 290
(Flexible tube part)
125
(Filter part)
44
ø 80 hole
98
ø 80 hole
(Piping and wiring intake)
Mounting location
1
Name plate location: right side surface of casing
2
In case of using an infrared remote control, this position will be
a signal receiver. Refer to the drawing of an infrared remote
control in detail.
3D034903C
FXAQ40,50MA
90 or more
(required space)
Piping direction
Dimensions for
full open front panel
Name plate Note 2
Piping direction
14.5
50 or more
(Required space)
104
Piping direction
1,050
125
(Filter part)
Description
ø 12.7 Flare connection
ø 6.4 Flare connection
VP13 (External dia. ø 18)
M4
NOTES
Approx. 290
(Flexible tube part)
Approx. 415
44
44
60
120 or less
Part name
Front panel
Front grill
Air outlet
Gas pipe
Liquid pipe
Drain hose
Grounding terminal
Right side pipe connection hole
Left side pipe connection hole
Approx. 475
Approx. 460
105
155
(Filter part)
2,500 or more
For installation
50 or more
(Required space) in high places
52
894
Outside line
ø 80 hole
Nr
1
2
3
4
5
6
7
8
9
30 or more
(required space)
290
Approx. 400
232
230
98
ø 80 hole
(Piping and wiring intake)
Mounting location
1
Name plate location: right side surface of casing.
2
In case of using an infrared remote control, this position will be
a signal receiver. Refer to the drawing of the infrared remote
control in detail.
3D038539B
10
• VRV® Systems • Indoor Units
• Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE
6
Dimensional drawing & centre of gravity
6-1
Dimensional drawing
FXAQ63MA
90 or more
(required space)
Piping direction
Dimensions for
full open front
panel
Piping direction
14.5
50 or more
(Required space)
Name plate Note 2
Piping direction
50 or more
(Required space)
1,050
104
Description
ø 15.9 Flare connection
ø 9.5 Flare connection
VP13
M4
NOTES
125
(Filter part) Approx. 415
44
44
60
120 or less
Part name
Front panel
Front grill
Air outlet
Gas pipe
Liquid pipe
Drain hose
Grounding terminal
Right side pipe connection hole
Left side pipe connection hole
Approx. 475
Approx. 460
105
155
(Filter part)
2,500 or more
For installation
in high places
52
894
Outside line
ø 80 hole
Nr
1
2
3
4
5
6
7
8
9
30 or more
(required space)
Approx. 400
232
230
98
ø 80 hole
(Piping and wiring intake)
Mounting location
1
Name plate location: right side surface of casing.
2
In case of using an infrared remote control, this position will be
a signal receiver. Refer to the drawing of the infrared remote
control in detail.
3D038541B
• VRV® Systems • Indoor Units
11
• Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE
7
Piping diagram
FXAQ-MA
Heat exchanger
Fan
Liquid pipe connection port
Filter
Electronic
expansion valve
Filter
Gas pipe connection port
Refrigerant flow
Cooling
Heating
Piping connection diameters
Model
Gas
Liquid
FXAQ20,25,32,40,50MA
ø12.7
ø6.4
FXAQ63MA
ø15.9
ø9.5
DU220-602J
12
• VRV® Systems • Indoor Units
• Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE
8
Wiring diagram
8-1
Wiring diagram
FXAQ-MA
Power supply
220-240V
220V
~
~
50Hz
60Hz
Note 5
Receiver/display unit
(Infrared remote control)
Note 2
Input from outside
Note 5
Transmission wiring
Central remote control
Note 1
Wired remote control
Side
Front
Control Box
(Indoor unit)
Indoor Unit
A1P
F1U
HAP
M1F
M1S
R1T
R2T
R3T
X1M
X2M
,
Printed circuit board
Fuse (훾 , 3A, 250V)
Light emitting diode (Service monitor-green)
Motor (Indoor fan)
Motor (Swing flap)
Thermistor (Air)
Thermistor (Coil liquid pipe)
Thermistor (Coil gas pipe)
Terminal block (Control)
Terminal block (Power)
: Terminal
: Connector
: Shows short circuit connector
: Field wiring
Y1E
Electronic expansion valve
PC
Power Circuit
Receiver/display unit (Attached to infrared remote control)
A2P
Printed circuit board
A3P
Printed circuit board
BS1
Push button (On/off)
H1P
Light emitting dide (On-red)
H2P
Light emitting diode (Timer green)
H3P
Light emitting diode (Filter sign-red)
H4P
Light emitting diode (Defrost-orange)
COLORS : BLK : Black
BLU : Blue
BRN : Brown
GRN : Green
ORG : Orange
SS1
SS2
Selector switch (Main/sub)
Selector switch (Wireless adress set)
Wired remote control
R1T
Thermistor (Air)
SS1
Selector switch (Main/sub)
Connector for optional parts
X15A
Connector (Float switch)
X35A
Connector (Group control adapter)
PNK : Pink
RED : Red
WHT : White
YLW : Yellow
NOTES
1
In case of using central remote control, connect it to the unit in accordance with the attached installation manual.
2
When connecting the input wires from outside, forced off or on/off control operation can be selected by remote control. In details, refer to the installation manual atached the unit..
3
Remote control model varies according to the combination system. Confirm engineering data and catalogs, etc.. before connecting.
4
Confirm the method of setting the selector switch (SS1, SS2) of wired remote control and infrared remote control by installation manual and engineering data, etc.
5
X24A is connected when the infrared remote control kit is being used.
3D034206C
• VRV® Systems • Indoor Units
13
• Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE
9
Sound data
9-1
Sound pressure spectrum
4D037087D
4D037088D
FXAQ25MA
Ocatve band sound pressure level dB (0dB=0.0002μ bar)
Ocatve band sound pressure level dB (0dB=0.0002μ bar)
FXAQ20MA
HI
LOW
Approximate
treshold hearing for
continuous noise
HI
LOW
Approximate
treshold hearing for
continuous noise
Ocatve band center frequency (Hz)
Ocatve band center frequency (Hz)
NOTES
1
2
3
4
NOTES
Over all (dB):
(B, G, N is already rectified)
Scale
Hi
35.0
39.5
Mode
1
Low
29.0
34.5
A
C
Operating conditons:
• Power source: 220-240V 50Hz / 220V 60Hz
• Cooling: Return air temperature: 27C DB, 19C WB; Outdoor temperature: 35C DB, 24C WB
• Heating: Return air temperature: 20C DB, 15C WB; Outdoor temperature: 7C DB, 6C WB
Measuring place: Anechoic chamber
Location of microphone
2
3
4
Over all (dB):
(B, G, N is already rectified)
Scale
1m
1m
1m
Mike
5
Mode
Low
A
29.0
C
34.0
Operating conditons:
• Power source: 220-240V 50Hz / 220V 60Hz
• Cooling: Return air temperature: 27C DB, 19C WB; Outdoor temperature: 35C DB, 24C WB
• Heating: Return air temperature: 20C DB, 15C WB; Outdoor temperature: 7C DB, 6C WB
Measuring place: Anechoic chamber
Location of microphone
1m
Hi
36.0
40.5
Mike
Operating noise differs with operation and ambient conditions.
5
4D037089D
4D038513A
FXAQ40MA
Ocatve band sound pressure level dB (0dB=0.0002μ bar)
Ocatve band sound pressure level dB (0dB=0.0002μ bar)
FXAQ32MA
Operating noise differs with operation and ambient conditions.
HI
HI
LOW
Approximate
treshold hearing for
continuous noise
LOW
Approximate
treshold hearing for
continuous noise
Ocatve band center frequency (Hz)
Ocatve band center frequency (Hz)
NOTES
1
2
3
4
NOTES
Over all (dB):
(B, G, N is already rectified)
Scale
Hi
37.0
41.5
Mode
1
Low
29.0
34.5
A
C
Operating conditons:
• Power source: 220-240V 50Hz / 220V 60Hz
• Cooling: Return air temperature: 27C DB, 19C WB; Outdoor temperature: 35C DB, 24C WB
• Heating: Return air temperature: 20C DB, 15C WB; Outdoor temperature: 7C DB, 6C WB
Measuring place: Anechoic chamber
Location of microphone
2
3
4
Over all (dB):
(B, G, N is already rectified)
Scale
Mode
Hi
Low
A
39.0
34.0
C
41.0
39.0
Operating conditons:
• Power source: 220-240V 50Hz / 220V 60Hz
• Cooling: Return air temperature: 27C DB, 19C WB; Outdoor temperature: 35C DB, 24C WB
• Heating: Return air temperature: 20C DB, 15C WB; Outdoor temperature: 7C DB, 6C WB
Measuring place: Anechoic chamber
Location of microphone
1m
1m
1m
1m
Mike
Mike
5
14
Operating noise differs with operation and ambient conditions.
• VRV® Systems • Indoor Units
5
Operating noise differs with operation and ambient conditions.
• Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE
9
Sound data
9-1
Sound pressure spectrum
4D038514A
4D038515A
FXAQ63MA
Ocatve band sound pressure level dB (0dB=0.0002μ bar)
Ocatve band sound pressure level dB (0dB=0.0002μ bar)
FXAQ50MA
HI
HI
LOW
LOW
Approximate
treshold hearing for
continuous noise
Approximate
treshold hearing for
continuous noise
Ocatve band center frequency (Hz)
Ocatve band center frequency (Hz)
NOTES
1
2
3
4
NOTES
Over all (dB):
(B, G, N is already rectified)
Scale
Hi
42.0
44.0
Mode
1
Low
36.0
39.0
A
C
Operating conditons:
• Power source: 220-240V 50Hz / 220V 60Hz
• Cooling: Return air temperature: 27C DB, 19C WB; Outdoor temperature: 35C DB, 24C WB
• Heating: Return air temperature: 20C DB, 15C WB; Outdoor temperature: 7C DB, 6C WB
Measuring place: Anechoic chamber
Location of microphone
2
3
4
Over all (dB):
(B, G, N is already rectified)
Scale
1m
1m
1m
Mike
5
Mode
Low
A
39.0
C
42.0
Operating conditons:
• Power source: 220-240V 50Hz / 220V 60Hz
• Cooling: Return air temperature: 27C DB, 19C WB; Outdoor temperature: 35C DB, 24C WB
• Heating: Return air temperature: 20C DB, 15C WB; Outdoor temperature: 7C DB, 6C WB
Measuring place: Anechoic chamber
Location of microphone
1m
Hi
46.0
48.0
Mike
Operating noise differs with operation and ambient conditions.
• VRV® Systems • Indoor Units
5
Operating noise differs with operation and ambient conditions.
15
• Indoor Units • WALL MOUNTED UNIT • FXAQ-MAVE
10
Installation
10 - 1 Service space
1
Select an installation site where the following conditions are fulfilled and that meets with your customer’s approval.
•
•
•
•
•
•
•
•
•
•
•
In the upper space (including the back of the ceiling) of the indoor unit where there is no possible dripping of water from the refrigerant pipe, drain pipe,
water pipe, etc.
Where the wall is strong enough to bear the indoor unit weight.
Where sufficient clearance for installation and maintenance can be ensured.
Where optimum air distribution can be ensured.
Where nothing blocks the air passage.
Where condensation can be properly drained.
Where the wall is not significantly tilted.
Where not exposed to combustible gases.
Where piping between indoor and outdoor units is possible within the allowable limit. (Refer to the installation manual of the outdoor unit.)
Keep the indoor and outdoor units, power cable and transmission wiring, at least 1 m from TVs and radios, to prevent distorted pictures and static.
(Depending on the type and source of the electrical waves, static may be heard even when more than 1 m away.)
Install the indoor unit no less than 2.5 m above the floor. Where unavoidably lower, take what measures are necessary to keep hands out of the air inlet.
Space required for installation (mm)
≥ 50
≥ 30
≥ 90
≥ 50
Obstruction
≤ 120
≥ 2500 (from floor)
for installation
in high place.
Floor
16
2
Consider whether the location where the unit will be installed can support the full weight of the unit, and reinforce it with
boards and beams, etc. if needed before proceeding with the installation. Also, reinforce the location to prevent vibration
and noise before installing.
3
The indoor unit may not be directly installed on the wall. Use the attached installation panel before installing the unit.
• VRV® Systems • Indoor Units
Daikin Europe N.V. is approved by LRQA for its
Quality Management System in accordance with the
ISO9001 standard. ISO9001 pertains to quality
assurance
regarding
design,
development,
manufacturing as well as to services related to the
product.
ISO14001 assures an effective environmental
management system in order to help protect human
health and the environment from the potential
impact of our activities, products and services and to
assist in maintaining and improving the quality of the
environment.
The present publication is drawn up by way of information only and
does not constitute an offer binding upon Daikin Europe N.V.. Daikin
Europe N.V. has compiled the content of this publication to the best
of its knowledge. No express or implied warranty is given for the
completeness, accuracy, reliability or fitness for particular purpose of
its content and the products and services presented therein.
Specifications are subject to change without prior notice. Daikin
Europe N.V. explicitly rejects any liability for any direct or indirect
damage, In the broadest sense, arising from or related to the use
and/or interpretation of this publication. All content is copyrighted
by Daikin Europe N.V..
EEDEN08-204 • 01/2008 • Copyright © Daikin
Daikin’s unique position as a manufacturer of air
conditioning equipment, compressors and
refrigerants has led to its close involvement in
environmental issues. For several years Daikin
has had the intension to become a leader in the
provision of products that have limited impact
on the environment. This challenge demands
the eco design and development of a wide
range of products and an energy management
system, resulting in energy conservation and a
reduction of waste.
Daikin units comply with the European
regulations that guarantee the safety of
the product.
Naamloze Vennootschap
Zandvoordestraat 300
B-8400 Oostende, Belgium
www.daikin.eu
BTW: BE 0412 120 336
RPR Oostende
VRV® products are not within the scope of the
Eurovent certification programme.
ÈEEDEN08-204aËÍ
The present publication supersedes EEDEN07-200
Prepared in Belgium by Lannoo (www.lannooprint.be), a company whose concern for
the environmont is set in the EMAS and ISO 14001 systems.
Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B- 8400 Oostende
2e
Open as PDF