Wire Color Code
Pair
1
2
3
4
Polarity
Identification
(Classical)
Wire Color
USOC
Tip
White/Blue
5
5
5
Ring
Blue or Blue/White
4
4
4
Tip
White/Orange
3
3
1
Ring
Orange or Orange/White
6
6
2
Tip
White/Green
2
1
3
Ring
Green or Green/White
7
2
6
Tip
White/Brown
8
7
7
Ring
Brown or Brown/White
1
8
8
1
USOC
PR2
PR2
PR1
+ +
-
+
PR3
- -
+
1 2 3 4 5 6 7 8
+
-
-
+
4
Push up
on tab
Figure 5
PR3
PR1
+
2
T568B
T568A
PR4
PR3
-
T568A
T568B
Pin
Pin
Number Number
PR4
-
+
-
1 2 3 4 5 6 7 8
PR2
+
-
PR1
+
-
+
PR4
-
+
-
1 2 3 4 5 6 7 8
Figure 6
OEM Systems Company, Inc., Sparks, NV www.oemsystems.com
Installation of RJ-45 and Cat 5 Jack
Tools Required:
•
•
•
110 Punch Down Tool or inexpensive 110 Push Tool (Available from OEM Systems Co.)
Diagonal wire cutters
Wire striper
Procedure:
Protective
Covers
Figure 2
1
2
4
Push Down
to insert
wire.
Figure 3
Push up
on tab
6
Figure 1
5
•
•
3
•
•
6
•
5
•
•
•
Remove the jack module(s) from the Decora plate by pushing up on the tab with your
thumb or blunt object. The plastic handle of 110 push tool works well for this. The jack
will pop out the back of the plate. (Figure 1)
Remove the two strain relief covers that protect the connecting block. (Figure 2)
Strip off about 1-1/2 inches of the outer jacket from the wire.
The label of the jack has a row of numbers that correspond to the pin numbers. There is
also an upper and lower row of color codes labeled A and B that correspond to the
T568A and T568B standards respectively. For USOC connections, use the color code
table to determine the wire color for each pin number. (Figure 6 and Color Code Table)
Being careful no to completely un-twist the colored pairs, separate the ends of the conductor pairs so that they can be laid into the appropriate slots of the jack’s connecting
block. (Figure 3)
On a firm surface, punch the conductors into their slots using a 110 tool. (Figure 4)
Cut off excess wire. This will not be necessary if you use a 110 punch tool with integral
cutting edge.
Replace the two protective strain relief covers.
Snap the module back into the Decora plate while pushing up on the tab. (Figure 5)
3
•
Figure 4
IMPORTANT INSTRUCTIONS & PRECAUTIONS
PERTAINING TO INSTALLATION & USE OF
RJ-11 & RJ-45 category 5 Jack Products
When using your telephone equipment, basic precautions should always be followed to reduce
the risk of fire, electric shock and injury to persons, including the following:
•
Read and understand all instructions.
•
Follow all warnings and instructions marked on the product.
•
Do not use this product near water, for example, near a bathtub, wash bowl, kitchen sink, or
laundry tub, in a wet basement, or near a swimming pool.
•
Never push objects of any kind into this product through cabinet slots as they may touch
dangerous voltages.
•
Never install telephone wiring during a lightning storm.
•
Never install telephone jacks in wet locations unless the jack is specifically designed for use
in wet locations.
•
Never touch un-insulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
•
Use caution when installing or modifying telephone lines.