TiR125, TiR110, TiR105 Building Diagnostic and the Ti100 General

TiR125, TiR110,
TiR105 Building
Diagnostic and the
Ti100 General Use
Thermal Imagers
Technical Data
The lightest, most-rugged,
easiest–to-use professional
thermal imagers around.
Whether you’re searching for air leaks, hidden moisture, construction
defects, or other building issues, a Fluke thermal imager delivers a
huge competitive advantage—it allows you to work faster and more
efficiently, and document your findings.
Ti100
TiR125
Made in
the U.S.A.
of U.S. and
non U.S.
parts
TiR110
™
TiR105
Fluke CNX™ enabled
Building problems, defects and
general maintenance
Energy audit, building inspection,
and weatherization
Restoration, water damage,
and roofing
Key features
•Exclusive IR-OptiFlex™ focus system—ensures that images are
in good focus from 1.2 m (4 ft) and beyond for optimum image
clarity and scanning convenience. For shorter distances change to
manual mode with the touch of a finger (TiR110 and TiR125).
•Always have references handy—IR-PhotoNotes™ annotation
system—Quickly identify and keep track of inspection locations by
adding digital images of important information and surrounding
areas (TiR110 and TiR125).
•Find problems faster and easier with Fluke IR-Fusion® technology
(TiR125, TiR110, TiR105). Accurately identify potential issues by
combining digital and IR images.
•Capture additional measurements fast and conveniently from
up to five wireless modules at once using your Fluke thermal
imager and CNX™ wireless modules.
•Get further clarification with AutoBlend™ mode - the blending
of a digital and partially transparent IR image into a single
information-filled image (TiR125 only).
•Multi-mode video recording—focus-free video in visible light and
infrared with full IR-Fusion (TiR110 and TiR125 only).
•Easily communicate the location of problems with the
Electronic 8-Point Cardinal Compass (TiR125 and TiR110 only).
Spend less time in the field and more time growing your
business with these new Fluke thermal imagers.
Patented Fluke IR-Fusion® Technology
Enjoy the industry’s only point-and-shoot IR-Fusion
camera. Fluke patented technology provides the user
with both a digital and an infrared image in one to
precisely document problem areas.
IR-OptiFlex™ focus system
Scan for issues significantly faster than before
with Fluke’s revolutionary, ultra-rugged focus system.
The IR-OptiFlex focus system gives you optimum
focus by combining focus-free, ease-of-use with
the flexibility of manual focus on the same camera.
Detailed specifications
TiR125
TiR110
TiR105
Ti100
Building diagnostics
IR resolution (FPA size)
General use
160 x 120 FPA Uncooled Microbolometer
Spectral band
7.5 μm to 14 μm (long wave)
Capture or refresh rate
9 Hz
NETD (Thermal sensitivity)
≤ 0.10 °C at 30 °C target temp
(100 mK)
≤ 0.08 °C at 30 °C target temp (80 mK)
FOV (Field of view)
22.5 °H x 31 °V
IFOV (Spatial resolution)
3.39 mRad
Temperature measurement range
(not calibrated below -10 °C)
-20 °C to +150 °C
(-4 °F to +302 °F)
Temperature measurement accuracy
-20 °C to + 250 °C
(-4 °F to 482 °F)
± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
IR-OptiFlex™ focus system
Focus mechanism
PIP, FULL IR, FULL VISIBLE,
AutoBlend™
IR-Fusion® technology
Focus-free 1.2 m (4 ft) and beyond
PIP, FULL IR, FULL VISIBLE
CNX™ Wireless enabled
Low temperature (dewpoint)
—
Blue-Red, Grayscale, Inverted Grayscale, High-contrast,
Hot Metal, Ironbow, Amber, Inverted Amber
Standard palettes
Ultra Contrast™ palettes
Hot/cold markers
Blue-Red, Grayscale, Inverted
Grayscale, High-contrast,
Hot Metal, Ironbow, Amber,
Inverted Amber
Blue-Red, Ironbow, Grayscale,
Amber
Blue-Red, Grayscale, Ironbow
—
Yes
User definable spot markers
No, full IR only
Yes
High termperature, low
temperature (dewpoint), and
isotherm
Color alarms
PIP (1.2 m (4 ft)
to 4.6 m (15 ft)), FULL IR,
FULL VISIBLE
—
Three on camera and in SmartView®
Centerpoint
in SmartView® only
Yes
Centerbox (MIN/AVG/MAX)
Yes
—
Level and span control
Manual and auto
Minimum span in auto mode
2.5 °C
5 °C
Minimum span in manual mode
2.0 °C
2.5 °C
Minimum IR focus distance
15.25 cm (6 in)
122 cm (48 in)
Weight
0.726 kg (1.6 lb)
Size
28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
LCD display
3.5 inch diagonal (portrait format)
Visible camera
2 megapixel industrial-grade
Minimum parallax
~45.7 – 55.9 cm (~ 18 in – 22 in)
IR-PhotoNotes™ annotation system
Yes (3 images)
N/A
—
Laser pointer
Yes
Torch
Yes
Electronic (cardinal) compass
—
Yes
Emissivity correction
—
Yes
Transmission correction
Yes
Background (reflected) compensation
Multi-mode video recording
(standard AVI with MPEG encoding)
Multi-mode video recording
(radiometric .is3)
—
Yes
Voice annotation (audio)
Multi-mode video output
Yes (60 seconds) per image
—
Streaming USB video output
—
Yes (AVI with MPEG encoding)
—
Yes, radiometric .is3 for
approx. 2.5 to 5 minutes depending upon thermal scene
Memory review
—
thumbnail review
Battery (field-replaceable,
rechargeable)
Two
Battery life
One
4+ hours (each)*
External battery charging base
Charging power supply
Included
Optional (accessory)
Yes
*Assumes 50 % brightness of LCD
2 Fluke Corporation
N/A
~122 cm (48 in)
TiR125, TiR110, TiR105 Building Diagnostic and Ti100 General Use Thermal Imagers
TiR125
TiR110
TiR105
Buidling diagnostics
Drop test
Ti100
General use
2 meter (6.5 feet)
Ingress protection (IP) rating
(IEC 60529)
IP 54
Est. calibration cycle
Two-years
Multifunction card reader
Included
—
Memory storage
2 GB SD memory card
Direct download capability
mini USB direct download
Operating temperature range
-10 °C to +50 °C (14 °F to 122 °F)
Storage temperature range
-20 °C to +50 °C (-4 °F to 122 °F)
Operating humidity
Operating and storage 10 % to 95 %, non-condensing
Vibration and shock
2G, IEC 68-2-26 and 25G, IEC 68-2-29
Safety standards
CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
C Tick
IEC/EN 61326-1
EMI, RFI, EMC
EN61326-1; FCC Part 5
User manuals
Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian,
Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian
Standard warranty period
Two-years
Extended warranty and service plans
Yes
Ordering information
FLK-TiR125 9HZ
FLK-TiR110 9HZ
FLK-TiR105 9HZ FLK-TI100 9HZ
Building Diagnostics Thermal Imager
Building Diagnostics Thermal Imager
Building Diagnostics Thermal Imager
General Use Thermal Imager
Included with product
Thermal imagers are shipped with ac power adapter, lithium ion
smart battery (TiR125 includes two each—other models one each),
USB cable, SD memory card, hard carrying case, soft transport
bag, adjustable hand strap (left- or right-handed use), printed
users manual in English, Spanish, French, German and Simplified
Chinese, others on CD, SmartView software and warranty
registration card. TiR125 model also includes a two-bay charging
base and a multi-format USB memory card reader.
CNX wireless modules
FLK-CNX i3000 iFlex™ AC Current Clamp Module
FLK-CNX a3000 AC Current Clamp Module
FLK-CNX v3000 AC Voltage Module
FLK-CNX t3000 K-Type Temperature Module
®
Optional:
FLK-TI-VISOR2
FLK-TI-TRIPOD2
BOOK-ITP
FLK-TI-SBC3
FLK-TI-SBP3
TI-CAR CHARGER
™
Sun visor
Tripod mounting accessory
Introduction to Thermography Principles Book
External charging base and power supply
Extra lithium-ion rechargeable smart battery
Thermal imager vehicle charger
Not available in all countries.
For more information on CNX™ wireless thermal imagers
and other CNX™ solutions go to www.fluke.com/cnx
3 Fluke Corporation
TiR125, TiR110, TiR105 Building Diagnostic and Ti100 General Use Thermal Imagers
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2012-2013 Fluke Corporation. Specifications subject to
change without notice. Printed in U.S.A. 3/2013 4026536E_EN
Modification of this document is not permitted without
written permission from Fluke Corporation.
Open as PDF