Find Quality Products Online at:
Limited Warranty & Limitation of Liability
®
Each Fluke product is warranted to be free from defects in material and workmanship under normal use
and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs
and services are warranted for 90 days. This warranty extends only to the original buyer or end-user
customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product
which, in Fluke's opinion, has been misused, altered, neglected or damaged by accident or abnormal
conditions of operation or handling. Fluke warrants that software will operate substantially in accordance
with its functional specifications for 90 days and that it has been properly recorded on non-defective media.
Fluke does not warrant that software will be error free or operate without interruption.
GPS 430
GPS Synchronization Module
Instruction Sheet
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only
but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available
if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international
price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when product
purchased in one country is submitted for repair in another country.
www.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or
replacement of a defective product which is returned to a Fluke authorized service center within the warranty
period.
GlobalTestSupply.com
To obtain warranty service, contact your nearest Fluke authorized service center or send the product, with a
description of the difficulty, postage and insurance prepaid (FOB Destination), to the nearest Fluke authorized
service center. Fluke assumes no risk for damage in transit. Following warranty repair, the product will be
returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that the failure was caused by
misuse, alteration, accident or abnormal condition of operation or handling, Fluke will provide an estimate of
repair costs and obtain authorization before commencing the work. Following repair, the product will be
returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation
charges (FOB Shipping Point).
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR
ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING
LOSS OF DATA, WHETHER ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT,
TORT, RELIANCE OR ANY OTHER THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or
limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply
to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court of competent
jurisdiction, such holding will not affect the validity or enforceability of any other provision.
Fluke Corporation
P.O. Box 9090
Everett WA 98206-9090
USA.
Fluke Industrial B.V.
P.O. Box 90
7600 AB Almelo
The Netherlands
Introducing the GPS 430
The GPS 430 GPS Synchronization Module guarantees that the time clock uncertainty of the
Fluke 430 series Power Quality Analyzers does not exceed ±20 ms for 50 Hz signals,
according to IEC 61000-4-30.
This performance is necessary to ensure that Class A instruments produce the same 10
minutes aggregation results when connected to the same signal.
The GPS 430 can only be used on the Fluke 430 series Power Quality Analyzers.
Note:
The GPS system is operated by the government of the United States, which is solely
responsible for its accuracy and maintenance.
Unpacking
The following items should be included in the package:
• PM9080 Optically Isolated Interface Cable (Fig. 1)
• PM8907/808 Power Adapter (Fig. 2)
• GPS 430 Unit (Fig. 3)
• Instruction Sheet GPS 430 (this paper)
Check the contents of the shipping box for completeness. If something in the box has been
damaged or missing, contact your distributor or the nearest FLUKE sales or service office
immediately.
sales@GlobalTestSupply.com
Service Centers
To locate an authorized service center, visit us on the World Wide Web:
http://www.fluke.com
or call Fluke using any of the phone numbers listed below:
+1-888-993-5853
in USA and Canada
+31-40-2675-200
in Europe
+1-425-446-5500
from other countries
Fig. 1. PM9080
Fig. 2. PM8907
April 2006
© 2006 Fluke Corporation. All rights reserved.
Printed in the EU. All product names are trademarks
of their respective companies
Fig. 3. GPS 430
Find Quality Products Online at:
Using the GPS 430
PM8907/808 Specifications
Connect the PM8907 power adapter output to the GPS 430 power input.
• Universal switchable adapter 115V ±10% or 230V ±15%, with plug EN60320-2.2G
Check the preselected voltage setting on the PM8907/808, see the PM8907/808
Instructions below.
• Line frequency: 50, 60, and 400 Hz ±10%.
3.
Connect the PM8907 to the line voltage.
• Output current: 300 mA.
4.
Connect the PM9080 Optical Interface Cable to the GPS 430 and to the Power Quality
Analyzer.
• Power consumption: 7W maximum.
5.
Verify that the GPS 430 data are received by the Power Quality Analyzer:
select SETUP – TIME – GPS TEST. See also the Power Quality Analyzer Users Manual.
• Plus (+) voltage connected to outer contact of the 5-mm power jack.
1.
2.
Note: For proper reception, the GPS antenna should not be covered by metal.
• Output voltage: 15V.
• Output plug: 5-mm power jack per DIN 45232.
Symbols
International electrical symbols used are explained below.
www.
PM8907/808 Instructions
See explanation on Instruction Sheet
DOUBLE INSULATION (Protection Class)
GlobalTestSupply.com
Please read these instructions carefully before using the Power Adapter.
Caution
Before you connect the PM8907/808 to the local line, first check the preselected voltage
setting on this unit. You can find the voltage selector switch on the bottom of the
PM8907/808. If necessary, select the corresponding line voltage with the slide switch
and ensure that the proper voltage is visible in the window of the slide selector. (see
Fig. 2.)
For connection to the mains outlet, use a power cord that complies with national
standards.
• Observe the polarity 5-mm power jack; the outer contact is plus (+) polarity.
• Do not open the PM8907, it is not serviceable.
Conforms to relevant European standards.
UL Listed
sales@GlobalTestSupply.com