Fieldbus System
®
(Gateway Decentralized Type)
New
∗
∗ Except the SY, VQC
and S0700 valves
GW Unit which supports PROFINET added.
M12 connector type Input Unit added.
GW Unit (Gateway Unit)
Decentralized valve installation
Valves can be installed
near the actuators!
Reduced
piping space
and piping
materials
Reduced
wiring
space
Description
Compatible
protocol
Gateway
Decentralized
System 2
No need to set the
address for the
valve manifold and
Input Unit.
Number of Number of valve manifold Branch cable
inputs/outputs and Input Unit connections
length
New function
Web server function
Page 8
Gateway
Decentralized
System
Page 46
128 inputs/
128 outputs
Max. 16
Units
Max. 20 m
64 inputs/
64 outputs
Max. 8
Units
Max. 10 m
• Valve operation test
• Connection diagnostic
• Short-circuit diagnostic
Page 2
—
Input Unit
(M8 connector type)
Input Unit
(M12 connector type)
Valve manifold
Series EX500
CAT.E02-26A
Series EX500
Fieldbus System
Gateway Decentralized System 2 (128 Points)
Number of branch ports: 4
Number of inputs/outputs
128 inputs/128 outputs
Number of inputs/outputs per branch: Max. 32 inputs/32 outputs
Number of valve manifold connections
Max.
8 Units∗
Number of valve manifold connections per branch: Max. 2 Units∗
Total cable length per branch Max.
Number of Input Unit connections Max.
Number of Input Unit connections per branch: Max. 2 Units
8 Units
20 m
∗ When the number of outputs is set to "16 outputs" using a built-in setting switch of the SI Unit.
Maximum number of inputs:
<Wiring example>
Max. number of inputs: 32
Max. number of outputs: 32
Input Unit
128 points Maximum number of outputs: 128 points
Max. number of inputs: 32
Max. number of outputs: 32
Valve manifold
Max. number of inputs: 32
Max. number of outputs: 32
Valve manifold
Max. number of inputs: 32
Max. number of outputs: 32
Input Unit
PLC
Valve manifold
Input Unit
Valve manifold
Input Unit
Communication cable
(Industrial network)
Valve manifold
Valve manifold
Input Unit
Power
supply
GW Unit
Input Unit
Branch cable (Subnetwork)
Setting switch
Branch port
Two valve manifolds can be connected to
one branch port.
SI Unit has a built-in setting switch which switches the number of
outputs (32 points / 16 points) of the valve manifold connected to the
SI Unit. By setting the number of outputs to 16 points, two valve
manifolds can be installed to one branch port.
SI Unit
1
Web server function
Valve operation test (ON/OFF), connection diagnostic between valve manifold and Input Unit, and short-circuit
diagnostic of input device can be performed on a Web browser.
A password can be used for the valve operation test (ON/OFF) for security.
The location of the error can be identified. Details of
the error can be identified on a Web browser.
Green LED flashing
These ports are in error.
Red LED ON
∗ WEB display example
PC
RJ-45 connector
COM D
COM C
COM B
COM A
Open circuit
16 Inputs
32 Outputs
16 Inputs
Auto switch
Short circuit
16 Outputs
16 Inputs
16 Outputs
16 Inputs
No need to set the address
I/O mapping for the SI Unit and Input Unit is set by the Gateway Unit automatically.
The Unit installation order is not specified.
(The upper limit of the inputs / outputs is 32 points for one branch port.)
2
Series EX500
Fieldbus System
Gateway Decentralized System 2 (128 Points)
Reduced wiring
Flexibly copes with changes in the protocol.
The amount of communication and power supply wiring
for the I/O device can be reduced.
Previously, it was necessary to change the part number of the slave
unit, return the slave unit, and make arrangements once again to
obtain a new unit (additional quotation, delivery period control).
d
Only the GW Unit needs to be changed.
Reduction of number of communication nodes
By reducing the number of communication nodes, the
load on the network is reduced.
Accessories can be
ordered together.
Page 12
Page 54
Accessories including cables and connectors can be ordered together to SMC.
Time for selecting parts, ordering and managing lead time can be reduced.
Applicable to output devices
other than valve manifold.
Page 14
By using output block,
lights and buzzers can be operated.
Output block
Output device
Solenoid valve
Power supply
Others
Indicator light, Relay,
Buzzer
Specified valve manifold can be controlled by supplying power from a different system.
Page 13
By using a Y branch connector, power from a different system can be supplied to the SI Unit (valve manifold).
<Example of use>
Power
supply A
Work pieces
machined by
robots
Valve manifold for
holding a workpiece
when robots are
operating
Operator places work
pieces. (Parts supply)
Rotational
workbench
Power is off when
parts are being
positioned.
Valve manifold for
holding a workpiece
when supplying
parts
Y branch connector
Power
supply B
3
System Comparison Table
Gateway Decentralized System 2
Gateway Decentralized System
(Current model)
Protocol
128 inputs/128 outputs
(32 inputs/32 outputs)
64 inputs/64 outputs
(16 inputs/16 outputs)
Max. 8 Units∗
(Max. 2 Units)
Max. 4 Units
(1 Unit)
(Number of connections per branch)
Max. 8 Units
(Max. 2 Units)
Max. 4 Units
(1 Unit)
Branch cable length
Max. 20 m
Max. 10 m
Enclosure
GW Unit: IP65
SI Unit: IP67
Input Unit: IP67
GW Unit: IP65
SI Unit: IP67
Input Unit: IP65
Function
Web server function
(Valve operation test, Connection
diagnostic, Short-circuit diagnostic)
—
Page
8
46
Number of inputs/outputs
(Number of inputs/outputs per branch)
Number of valve manifold connections
(Number of connections per branch)
Number of Input Unit connections
∗ When the number of outputs is set to "16 outputs" using a built-in setting switch of the SI Unit.
Applicable Valve Series
Flow rate characteristics (4/2씮5/3) Maximum Power consumption
International
number of
Enclosure
Page
[W]
standard
C [dm3/(s·bar)]
b
solenoids
Series
SY3000
1.6
0.19
SY5000
3.6
0.17
SY7000
5.9
0.20
VQC1000
1.0 Note) 0.30 Note)
VQC2000
3.2 Note) 0.30 Note)
VQC4000
7.3 Note) 0.38 Note)
VQC5000
17.0 Note) 0.31 Note)
32
0.35 (Standard)
0.1 (With power
saving circuit)
[Inrush 0.4, Holding 0.1]
IP67
17
IP67
25
37
0.4 (Standard)
24
S0700
0.37
0.39
SV1000
1.1
0.35
SV2000
2.4
0.18
0.95 (Standard)
0.4 (Low-wattage type)
32
0.35
IP40
32
0.6
IP67
40
®
SV3000
4.3
0.21
Note) Values for 2-position single, rubber seal type
4
Series SY3000/5000/7000
Piping on the top or the bottom makes the footprint
smaller to realize dramatic space-saving.
Valve piping direction variations
Max. 24 stations connectable
Piping is possible from 3 directions.
It is possible to connect only the number of valves
required, from 1 to 24 stations, to suit the application.
(Maximum number of solenoids: 32)
Top ported
Side ported
Side ported
Mixed mounting of top ported
and side ported is possible.
Bottom ported
Mixed valve sizes manifold
It is also possible to install a combination of different-sized valves on the same manifold. (SY3000 and
SY5000, or SY5000 and SY7000)
This facilitates reduction in the installation space and number of units/cables.
Example: For SY5000 and SY3000
Overall length of manifold
Single manifold
Single manifold
Mixed manifold
SY5000 3 stations
SY3000 5 stations
SY5000 3 stations SY3000 5 stations
Installation
space
+
135.2 mm
136.7 mm
Number of
Fieldbus Units/
Unit cost
2 sets
Manifold
Fieldbus Unit
5
Approx. 31%
reduction
redu
186.9 mm
50%
reduction
1 set
2 pcs.
2 sets
Manifold
Fieldbus Unit
1 pc.
1 set
CONTENTS
Fieldbus System (Gateway Decentralized Type) Series EX500
Features (Gateway Decentralized System 2)
System Comparison Table/Applicable Valve Series
Introduction of the SY Series Valve
Series EX500
Gateway Decentralized System 2 (128 Points)
Page 1
Page 4
Page 5
Page 8
GW Unit
How to Order
Specifications
Dimensions/Parts Description
SI Unit
How to Order
Specifications
Dimensions/Parts Description
Input Unit
How to Order
Specifications
Dimensions/Parts Description
Accessories
• Power Supply Cable • Communication Cable/Connector
• Branch Cable • Y Branch Connector • Cable for Power Supply from a Different System
• Marker • Seal Cap • DIN Rail Bracket
• Output Block
• Power Block
• Connector for Output Block Wiring • Power Supply Cable for Power Block
• End Plate • Bracket Plate
SY3000/5000/7000
How to Order: Type 10/Type 11
Type 12
Dimensions: Type 10 SY3000
SY5000
SY7000
Page 9
Page 9
Page 9-1
Page 10
Page 10
Page 10
Page 11
Page 11
Page 11
Page 12
Page 13
Page 13-1
Page 14
Page 14
Page 15
Page 16
Page 17
Page 20
Page 22
Page 23
Page 24
For dimensions of Type 11 and Type 12, refer to the SY series catalog (CAT. ES11-103).
VQC1000
How to Order
Dimensions
VQC2000
How to Order
Dimensions
VQC4000
How to Order
Dimensions
VQC5000
How to Order
Dimensions
S0700
How to Order
Dimensions
SV1000/2000/3000
How to Order
Dimensions: Tie-rod Base SV1000
SV2000
SV3000
Precautions on Mixed Usage of Gateway Decentralized System 2 and Gateway Decentralized System
Page 25
Page 27
Page 28
Page 30
Page 31
Page 33
Page 34
Page 36
Page 37
Page 39
Page 40
Page 42
Page 43
Page 44
Page 45
6
CONTENTS
Series EX500
Gateway Decentralized System (64 Points)
GW Unit
How to Order
Specifications
Dimensions/Parts Description
SI Unit (for SV)
How to Order
Specifications
Dimensions/Parts Description
SI Unit (for SY/VQC/S0700)
How to Order
Specifications
Dimensions/Parts Description
Input Manifold
How to Order
Specifications
Dimensions/Parts Description
How to Add Input Block Stations
Accessories
• Power Supply Cable • Branch Cable
• Communication Cable
• Terminal Plug • Seal Cap
SY3000/5000/7000
How to Order: Type 10/Type 11
Type 12
Dimensions: Type 10 SY3000
SY5000
SY7000
Page 46
Page 47
Page 47
Page 47
Page 48
Page 48
Page 48
Page 49
Page 49
Page 49
Page 50
Page 51
Page 52
Page 53
Page 54
Page 55
Page 56
Page 57
Page 60
Page 62
Page 63
Page 64
For dimensions of Type 11 and Type 12, refer to the SY series catalog (CAT. ES11-103).
VQC1000
How to Order
Dimensions
VQC2000
How to Order
Dimensions
VQC4000
How to Order
Dimensions
VQC5000
How to Order
Dimensions
S0700
How to Order
Dimensions
SV1000/2000/3000/4000
How to Order
Dimensions: Cassette Base
M
R
CO
PW
Tie-rod Base
D
D
D
D
D
D
7
Page 65
Page 67
Page 68
Page 70
Page 71
Page 73
Page 74
Page 76
Page 77
Page 79
SV1000
SV2000
SV1000
SV2000
SV3000
SV4000
Page 80
Page 82
Page 83
Page 84
Page 85
Page 86
Page 87
Series EX500
Gateway Decentralized System 2 (128 Points)
Gateway Decentralized System 2
) Valve manifold and Input Unit can be connected around the GW (Gateway) Unit.
) Number of inputs/outputs = 128 points/128 points. The number of outputs (solenoids) per branch is 32 points.
) Number of valve manifold connections = Max. 8 Units, Number of Input Unit connections = Max.
8 Units, Branch cable length = Max. 20 m
) Web server function (Valve operation test, connection diagnostic of Units, short-circuit diagnostic
of input devices)
) No need to set the address for the valve manifold and Input Unit.
SY
VQC
S0700
SV
SY3000/5000/7000
Page 17
VQC1000/2000/4000/5000
Page 25
S0700
Page 37
SV1000/2000/3000
Page 40
8
Series EX500
Gateway Decentralized System 2 (128 Points)
GW Unit
®
RoHS
How to Order
EX500 G EN2
Communication protocol
EtherNet/IP™
EN2 (Input/Output = 128 points/128 points)
PROFINET
PN2 (Input/Output = 128 points/128 points)
Specifications
Model
Protocol
Version Note 2)
Media
Communication speed
Communication method
Number of inputs/
outputs
(I/O occupation area)
Communication
Configuration file Note 3)
EX500-GEN2
EX500-GPN2
EtherNet/IP TM Note 1)
PROFINET IO
Volume 1 (Edition 3.14)
Volume 2 (Edition 1.15)
PROFINET Specification
Version 2.2
100BASE-TX
100BASE-TX
10/100 Mbps (Automatic)
100 Mbps
Full duplex/Half duplex (Automatic)
Full duplex
128 inputs/128 outputs
(20 bytes/20 bytes)
128 inputs/128 outputs
(18 bytes/16 bytes)
EDS file
GSDML
Switch settings: 192.168.0.1 to 254 or
192.168.1.1 to 254,
Through DHCP server: Optional address
Optional address
Device information
Vendor ID: 7 (SMC Corporation)
Product type: 12 (Communication Adapter),
Product code: 198
—
Applicable function
DLR
QuickConnect TM
Web server
MRP
Fast Start Up
Web server
IP address setting range
Power supply
voltage
For input and control
Current
consumption
For input and control
24 VDC ±10%
For valve
For output (valve)
24 VDC +10%, –5%
6.2 A or less
(Max. 1.5 A per branch x 4 branches + GW Unit internal current consumption: 0.2 A or less)
4 A or less (Max. 1 A per branch x 4 branches)
Number of branch ports
Branch port
4 ports
Number of inputs and
outputs
32 inputs/32 outputs per branch
Branch cable length
20 m or less per branch
Enclosure
Environment
Standards
IP65
Operating
temperature range
Operating: –10 to 50°C, Stored: –20 to 60°C
(No condensation)
Operating humidity
range
Operating, Stored: 35 to 85%RH
(No condensation)
CE marking, UL (CSA), RoHS compliant
Weight
Enclosed parts
550 g
Seal cap (for M12 connector socket) 5 pcs.
Note 1) Use a CAT5 or higher communication cable.
Note 2) Please note that the version is subject to change.
Note 3) Each file can be downloaded from SMC website, http://www.smcworld.com
9
Gateway Decentralized System 2 (128 Points)
GW Unit
Series EX500
Dimensions/Parts Description
EX500-GEN2 (EtherNet/IPTM)
Mounting hole
4 x M5
148
28.9
Indicator LED
Ground terminal (FE)
M3
12
14
40
67.6
68
Communication connector (Port 1)
M12, 5 pins, D-coded, socket
Communication connector (Port 2)
M12, 5 pins, D-coded, socket
88
Power supply connector
7/8 inch, 4 pins, plug
Cover (Setting switch)
Gateway Decentralized System 2
Cover screw
4 x M3
Branch port
M12, 8 pins, A-coded, socket
28
60
3 x 23
SY
160
10
47.5
48.8
VQC
55.5
136
S0700
SV
EX500-GPN2 (PROFINET)
Cover screw
4 x M3
Power supply connector
7/8 inch, 5 pins, plug
Cover (Setting switch)
Mounting hole
4 x M5
148
28.9
Indicator LED
Ground terminal (FE)
M3
Communication connector (Port 1)
M12, 5 pins, D-coded, socket
Communication connector (Port 2)
M12, 5 pins, D-coded, socket
88
12
14
40
67.6
68
GATEWAY UNIT
Branch port
M12, 8 pins, A-coded, socket
28
60
3 x 23
160
10
47.5
48.8
55.5
136
9-1
Series EX500
Gateway Decentralized System 2 (128 Points)
SI Unit
®
Output Unit for valve manifold connection
How to Order
RoHS
EX500 S103
Specifications
EX500-S103
Model
Applicable valve
SY, VQC, S0700, SV
Number of outputs
16/32 outputs (Switched by built-in setting switch)
Output type
Output
Source/PNP (Negative common)
Rated voltage
24 VDC
Supply current
With power supplied to GW Unit: Max. 1.0 A
With external power∗ supplied: Max. 1.5 A
Internal current consumption
50 mA or less
Enclosure
Environment
IP67
Operating temperature range
Operating: –10 to 50°C, Stored: –20 to 60°C (No condensation)
Operating humidity range
Operating, Stored: 35 to 85%RH (No condensation)
Standards
CE, UL (CSA), RoHS compliant
Weight
200 g
Seal cap (for M12 connector socket) 1 pc.
Enclosed parts
Valve manifold mounting screw (M3 x 30) 2 pcs.
∗ When an accessory, Y branch connector, is used.
Dimensions/Parts Description
22.5
28.2
Indicator LED
Cover screw
M3
Branch connector (IN)
M12, 8 pins, A-coded, plug
Cover (Setting switch)
101.4
99.9
Branch connector (OUT)
M12, 8 pins, A-coded, socket
25.4
46
67
76.5
90.9
11.3
10
Ground terminal (FE)
M3
Series EX500
Gateway Decentralized System 2 (128 Points)
Input Unit
®
RoHS
How to Order
Input unit
Connector type
A
B
M8 connector type
M12 connector type
Specifications
EX500-DXPA
Model
Connector type
Number of inputs
Input type
Rated voltage
Input
EX500-DXPB
M8 connector
M12 connector
16 inputs
PNP
24 VDC
Max. 1.3 A/Unit
Total of 8 connectors of even number must be Max. 0.65 A,
8 connectors of odd number must be Max. 0.65 A
11 V or more/Typ. 7 mA (at 24 VDC)
5 V or less/1.5 mA or less
200 mA or less (when the input signal is ON)
IP67
Operating: –10 to 50°C, Stored: –20 to 60°C (No condensation)
Operating, Stored: 35 to 85%RH (No condensation)
CE, UL (CSA), RoHS compliant
250 g
450 g
Seal cap (for M8 connector socket) 16 pcs.
Seal cap (for M12 connector) 17 pcs.
Seal cap (for M12 connector socket) 1 pc.
S0700
Enclosed parts
VQC
Input ON voltage/Input ON current
Input OFF voltage/Input OFF current
Internal current consumption
Enclosure
Environment Operating temperature range
Operating humidity range
Standards
Weight
]
SY
[
Supply current
EX500-DXPB
SV
Dimensions/Parts Description
EX500-DXPA
12.9
Ground terminal (FE)
Branch connector (IN)
M12, 8 pins,
A-coded, plug
Branch connector (OUT)
M12, 8 pins,
A-coded, socket
49
37
24.5
Ground terminal (FE)
12
Indicator LED
Indicator LED
251
222.65
201.65
7 x 20
237.5
Branch connector (OUT)
M12, 8 pins,
A-coded, socket
Connector
M8, 3 pins,
socket
25.05
Indicator LED
6.75
2 x M4
24.5
15
30
45
60
(16)
41.3
40.3
13.2
12
(7.5)
35.2
34.3
Connector
M12, 5 pins,
socket
121.7
149
138
Branch connector (IN)
M12, 8 pins,
A-coded, plug
Gateway Decentralized System 2
EX500 DX P A
11
Series EX500
Gateway Decentralized System 2 (128 Points)
Accessories
q Power Supply Cable
w Communication Cable/Connector
Supplies power to the GW Unit.
Connects Fieldbus to the GW Unit.
For EtherNet/IPTM
Cable with connector
PCA 1416000
PCA 1446566
Connector specification, Cable length (L)
3
47.3
5000
50
L
7/8 inch
53
M12
SPEEDCON
D-coded
2
1
3
4
L
Yellow: TD +
White: RD +
Orange: TD –
Blue: RD –
1
2
3
4
Plug pin
arrangement
ø10.7
26.5
40.4
Socket pin
arrangement
5000 [mm]
(ø6.5)
4
1
1446566
ø10.7
49.9
36
2
Cable length
Straight 2 m
Straight 6 m
Angle 2 m
Angle 6 m
ø14.8
1415999
1415996
1416000
1415997
Connections
7/8 inch
3
2
1
Field wireable connector
PCA 1446553
Socket pin arrangement
3
4
Connections
PCA 1558810
1558810
1558823
1558836
1558849
Straight 2 m
Straight 6 m
Angle 2 m
Angle 6 m
49.9
Width across
flats 13
Cable O.D.
Wire gauge (Stranded wire cross section)
4.0 to 8.0 mm
0.14 to 0.34 mm2/AWG26 to 22
Cable with M12 ↔ RJ-45 connector
EX9 AC 020 EN PSRJ
010
020
030
050
100
ø12.58
ø7/8"
ø26
M12
1
2
5
4
1000 [mm]
2000 [mm]
3000 [mm]
5000 [mm]
10000 [mm]
Red/White: 0 V (for solenoid valve)
Red: 0 V (for control and input)
Green: FE
Red/Orange: 24 VDC (for solenoid valve)
Red/Black: 24 VDC (for solenoid valve)
3
4
5
Connections
RJ-45
L
47.3
2
1
3
4
Socket pin arrangement
1
M12 plug (Straight)
⇔ RJ-45 connector
PSRJ
45
D-coded
3
2
Connector specification
ø6.7
ø12.58
L
26.5
53
40.4
Width across
flats 16
Cable length (L)
Socket pin
arrangement
12
M12
L
ø7/8"
ø26
5
4
Note) The table above shows the specifications for the applicable cable. Adaptation for the
connector may vary on account of the conductor construction of the electric wire.
36
3
1
3
Applicable Cable
Connector specification, Cable length (L)
4
1
Plug pin
arrangement
For PROFINET
2
2
ø19
2
61
D-coded
Red: 24 VDC (for solenoid valve)
Green: 24 VDC (for control and input)
White: 0 V (for control and input)
Black: 0 V (for solenoid valve)
1
ø17.5
4
1
2
3
4
5
6
7
8
1
2
3
4
Plug pin
arrangement
White/Orange
Orange
White/Green
Green
Shield
Connections
1
2
3
4
5
6
7
8
Plug pin
arrangement
Gateway Decentralized System 2 (128 Points)
Accessories
Series EX500
r Y Branch Connector
<Example of use>
Supplies separate power to valve manifold when it is connected to the
SI Unit.
Gateway Decentralized System 2
; Y branch connector
EX500 ACY01 S
. Branch cable
M12
51.7
16.9
e Branch Cable
.2
ø4
Connects the GW Unit and SI Unit or Input Unit.
ø14.8
21
= Cable for power supply
from a different system
16
M12
21.2
EX500 AC 030
SSPS
A-coded
Pin Layout of the Cable for Power
Supply from a Different System
1
Cable length (L)
3
1
2
3
4
4
Plug pin
arrangement
24 VDC +10%, –5% (for solenoid valve)
0 VDC (for solenoid valve)
Unused
Unused
t Cable for Power Supply from a Different System
ø14.9
ø6
44.7
EX500 AP 050
S
Cable length (L)
M12
M12
A-coded
A-coded
Connector specification
S
A
1000 [mm]
5000 [mm]
Plug
M12
A-coded
M12
25.3
A-coded
5
30
25.3
50
L
Plug
PCA 1401804
Cable length (L)
1401804 1500 [mm]
1401805 3000 [mm]
1401806 5000 [mm]
44.5
M12
SPEEDCON
L
50
ø5
ø14.8
Socket
5
50
ø6
L
L
28.3
25.3
30
40.7
32.3
28.3
ø6
M12
ø14.9
Socket
ø6
M12
Straight
Angle
SV
010
050
A-coded
51
2
Brown: 24 VDC (+10%, –5%, Solenoid valve power supply)
White: 0 V (Solenoid valve power supply)
Blue: Not connected
Black: Not connected
Gray Note 1), Green/Yellow Note 2): Not connected
1
2
3
4
3
Socket pin
arrangement
4
5
Connections
S0700
40.7
Connect to Y branch connector to supply power.
VQC
Socket side: Straight,
SSPS Plug side: Straight
Socket side: Angle,
SAPA Plug side: Angle
L
ø14.9
2
Connector specification
300 [mm]
500 [mm]
1000 [mm]
3000 [mm]
5000 [mm]
10000 [mm]
SY
003
005
010
030
050
100
M12
12.9
39
ø14.8
Note 1) For EX500-AP;-;
Note 2) For PCA-;
13
Series EX500
y Marker (1 sheet, 88 pcs.)
Signal name of the input device such as a switch can be written on
the marker and installed to the Input Unit.
EX600-ZT1
u Seal Cap (10 pcs.)
Use with new connector. By using these waterproof caps, the new
connector maintains IP65/67 enclosure.
EX9-AWES
EX9-AWTS
For M8 connector socket For M12 connector socket
i DIN Rail Bracket (2 pcs.)
Bracket for mounting the Input Unit (EX500-DXPA, EX500-DXPB) to
DIN rail.
EX500 ZMA1
<Example of use>
13-1
Gateway Decentralized System 2 (128 Points)
Accessories
Series EX500
8 Output block
Output devices other than valve manifold can be
operated.
Power block
Output device
Solenoid valve
2 point outputs per output block (M12 connector)
Power supply
Others
Indicator light, Relay, Buzzer
o Output Block
You are requested to connect it to an SI Unit and a valve manifold.
For detailed specifications, refer to the Operation Manual that can
be downloaded from SMC website, http://www.smcworld.com
!0 Power Block
OE T 1
EX9
Possible to mount the output block and power
block additionally between the SI Unit and the
valve (The surplus I/O points are used).
EX9
PE1
SY
Output specification
1
Gateway Decentralized System 2
By using the power block and output block for
high watt load, operation up to 0.5 A/1 point can
be performed.
Source/PNP (Negative common)
VQC
Power supply type
S0700
T Internal power supply method (for low-wattage load)
P Integrated power supply method (for high-wattage load) Note)
Note) Required to connect with a power block.
Dimensions/Parts Description
Dimensions/Parts Description
Position indicator LED
64.4
80.3
64.4
72.6
SV
Position indicator LED
PWR
Output type
Number of outputs
Output
Power supply
method
Output device supply voltage
43.2
21
21
26.7
Specifications
EX9-OET1
EX9-OEP1
40 mA or less
Enclosure
Operating humidity range
Standards
Weight
Model
Connection block
EX9-PE1
Output block for high wattage load
Source/PNP (Negative common)
Connection block stations
Output block: Max. 8 stations
2 outputs
Power supply for output Power supply voltage
and internal control
Internal current consumption
22.8 to 26.4 VDC
Internal power
supply method
Integrated power supply method
(Power block: supplied from EX9-PE1)
Supply current
24 VDC
Output device supply current Max. 42 mA/point (1.0 W/point) Max. 0.5 A/point (12 W/point)
Environment Operating temperature range
Power supply input connector
(M12, 5 pins, plug,
B-coded)
26.7
Specifications
Model
Internal current consumption
59.8
22.2
43.2
59.8
Power supply connector
(unused)
21.2
22.2
Connector for
output device connection
(M12, 5 pins, socket,
A-coded)
21.2
Enclosure
Environment Operating temperature range
IP67
–10 to 50°C
35 to 85%RH (No condensation)
CE marking, UL (CSA), RoHS compliant
120 g
Operating humidity range
Standards
Weight
Enclosed parts
20 mA or less
Max. 3.1 A Note)
IP67
–10 to 50°C
35 to 85%RH (No condensation)
CE marking, UL (CSA), RoHS
120 g
Seal cap (for M12 connector) 1 pc.
Note) When using with 3.0 to 3.1 A, the ambient temperature should not
exceed 40°C, and do not bundle the cable.
14
Series EX500
!1 Connector for Output Block Wiring
Field wireable connects the output device to the output block.
PCA 1557743
(55)
A-coded
1
ø14.8
ø16.3
2
2
4
3
M12
SPEEDCON
Width across flats 13
1
4
Plug pin
arrangement
Applicable Cable
Cable O.D.
Wire gauge (Stranded wire cross section)
3.5 to 6.0 mm
0.14 to 0.34 mm2/AWG26 to 22
Core wire diameter (Including insulating material)
0.7 to 1.3 mm
Brown: Not connected
White: Output 1
Blue: 0 V
Black: Output 0
3
Connections
PCA 1557756
(55)
A-coded
1
ø18.4
ø14.8
SW15
2
2
4
3
M12
SPEEDCON
Width across flats 15
1
4
Connections
Plug pin
arrangement
Applicable Cable
Cable O.D.
Wire gauge (Stranded wire cross section)
4.0 to 8.0 mm
0.34 to 0.75 mm2/AWG22 to 18
Core wire diameter (Including insulating material)
1.3 to 2.5 mm
Brown: Not connected
White: Output 1
Blue: 0 V
Black: Output 0
3
!2 Power Supply Cable for Power Block
Supplies power to the power block.
L
EX9 AC 050 1
48.1
1000 [mm]
3000 [mm]
5000 [mm]
PCA 1401807
M12
ø14.8
010
030
050
ø6.4
Cable length (L)
44.5
L
30
5
50
50
ø5
Cable length (L)
1401807 1500 [mm]
1401808 3000 [mm]
1401809 5000 [mm]
M12
SPEEDCON
B-coded
5 1
2
Brown: 24 VDC +10%, –5% (Power supply for output)
White: 0 V (Power supply for output)
1
2
3
4
4
3
Socket pin
arrangement
15
Gray Note 1), Green/Yellow Note 2): Ground
5
Connections
Note 1) For EX9-AC;-1
Note 2) For PCA-;
Gateway Decentralized System 2 (128 Points)
Accessories
Series EX500
!3 End Plate
Use when the output block is not used and the valve manifold is not connected.
EA03
Gateway Decentralized System 2
EX9
66
2 x M4 Mounting hole
12.5
<Example of use>
13.2
60
10
6
18
SY
75
VQC
!4 Bracket Plate
EX9
BP1
Dimensions
7.5
SV
4x
<Example of use>
(R
2x6
14
)
2 x 4.6
66
4.5
75
4
)
x
(R
29.5
1.2
5
17.5
45
3.05
34.6
2
45
15
3.
05
Accessory
Description
Hexagon socket head cap screw (M3 x 35)
S0700
A reinforcing brace used to mount output block or power block onto the SI Unit. To prevent connection failure between products due to
deflection, use this bracket plate whenever output block or power block is mounted.
Quantity
2
16
Gateway Decentralized System 2
Type 10
Side Ported
5 Port Solenoid Valve
Type 11
Bottom Ported
RoHS
Series SY3000/5000/7000
For detailed specifications, Common Precautions and Specific Product Precautions, refer to the WEB catalog or the SY series catalog (CAT. ES11-103).
How to Order Manifold
SS5Y 3
10 S A3N 05 U
q
w
q Series
u
Note 1) 16 outputs can be set by switching the
built-in setting switch.
Note 2) Ensure a match with the common specification of the valve.
Note 3) ( ): Maximum number of stations for
mixed single and double wiring.
Note 4) When using the SI Unit with 32 outputs,
use the GW Unit compatible with the
EX500 Gateway Decentralized System
2 (128 points).
w Type
Side ported
Bottom ported Note)
Note) The SY5000 manifold base is used for
the bottom ported of the SY3000. When
ordering, refer to the WEB catalog or the
SY series catalog (CAT. ES11-103).
∗ When mixing top ported configurations, select
from page 21.
In this case, use caution as there is also
output on the A and B port on base side.
Specify on a manifold specification sheet if
plugs are required on the A and B port on
base side.
How to Order Manifold Assembly
…
A3N
Stations
Note
02 2 stations
Double wiring Note 1)
16 16 stations
02 2 stations
…
Without SI Unit
32 outputs Note 1, 4), 1 to 16 stations (24
stations Note 3)), Negative common Note 2)
…
0
i
r Valve stations
Max. number of valve stations)
∗ For mixed mounting, refer to the WEB catalog
or the SY series catalog (CAT. ES11-103).
24 24 stations
Mixed wiring, Specified layout Note 2)
(Available up to 32 solenoids)
Note 1) Double wiring: 2-position single, double,
3-position and 4-position valves can be
used on all manifold stations.
Use of a 2-position single solenoid will
result in an unused control signal.
If this is not desired, order with a
specified layout.
Note 2) Specified layout: Indicate the wiring
specifications on the manifold
specification sheet. (Note that 2-position
double, 3-position and 4-position valves
cannot be used where single wiring has
been specified.)
Note 3) For the product without the SI Unit (S0),
note the maximum number of solenoids
of the SI Unit that will be mounted. If the
layout is specified, indicate it on the
manifold specification sheet.
∗ This also includes the number of blanking
plate assembly.
t P, E port entry
Example
Manifold base
t y
e SI Unit (Number of outputs, Output polarity,
SY3000
SY5000
SY7000
10
11
r
…
3
5
7
e
C6
U
D
B
2-position double
U side (2 to 10 stations)
D side (2 to 10 stations)
Both sides (2 to 24 stations)
y SUP/EXH block assembly
D
si
de
1
2
3
S
ta
t
io
ns
U
si
de
Nil
S
R
SS5Y3-10SA3N-05D-C6···1 set (Manifold base part number)
∗ SY3200-5U1···················5 sets (2-position double part number)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold base part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on the manifold specification sheet.
17
Internal pilot
Internal pilot, Built-in silencer Note 1) 2)
External pilot
Note 1) 3/5(E) port is plugged for the built-in
silencer type.
Note 2) When built-in silencer type is used,
keep the exhaust port from coming in
direct contact with water or other
liquids.
Gateway Decentralized System 2
5 Port Solenoid Valve
—
—
—
ø4
—
—
ø6
ø8
—
—
—
ø10
—
ø12
—
—
—
Mixed sizes
ø4
—
—
—
ø6
—
—
—
—
—
ø12
—
—
—
—
ø4
—
—
—
ø6
—
—
—
ø8
—
—
ø10
—
—
—
—
ø12
—
—
—
—
Mixed sizes
—
—
P, E port Note 3)
ø8
ø10
ø12
ø10
ø12
Downward
Elbow Note 2)
Upward
—
LM Note 1)
—
—
—
—
—
—
ø1/4"
—
ø5/16"
—
—
ø3/8"
—
Mixed sizes
—
—
—
—
—
—
—
—
—
—
—
—
ø5/32"
ø1/4"
ø5/16"
—
ø3/8"
—
—
ø5/32"
—
—
—
—
ø1/4"
—
—
—
ø5/16"
—
—
—
—
ø3/8"
—
—
—
—
—
—
ø1/2"
ø3/8"
ø1/2"
Mixed sizes
P, E port Note 3)
ø5/16" ø3/8"
SV
—
—
ø1/8"
ø5/32"
S0700
ø8
ø10
N1
N3
N7
N9
N11
CM Note 1)
LN3
LN7
LN9
LN11
BN3
BN7
BN9
BN11
Straight
—
—
Upward
—
—
Elbow Note 2)
—
Straight
Type 10/Side Ported Type 11/Bottom Ported
SY3000 SY5000 SY7000 SY5000 SY7000
VQC
ø2
ø3.2
—
LM Note 1)
A, B port
SY3000 SY5000 SY7000 SY5000 SY7000
SY
C2
C3
C4
C6
C8
C10
C12
CM Note 1)
L4
L6
L8
L10
L12
B4
B6
B8
B10
B12
A, B port size (Inch/One-touch fitting)
Type 10/Side Ported Type 11/Bottom Ported
Downward
A, B port
Gateway Decentralized System 2
u A, B port size (Metric/One-touch fitting)
Series SY3000/5000/7000
Note 1) Indicate the sizes on the manifold specification sheet.
Note 2) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly. For details, refer to the
WEB catalog or the SY series catalog (CAT. ES11-103).
Note 3) The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting
direction.
i Mounting and Option
Mounting
Nil
AA
BA
D Note 1)
A Note 1)
B Note 1)
Direct
mounting
DIN rail
mounting
Option
Name plate Station number
—
—
—
—
—
—
…
…
Note 1) Refer to “DIN Rail Option” below.
∗ Select the direct mounting type for Type 11 (Bottom ported).
DIN Rail Option
Nil With DIN bracket, DIN rail with standard length
With DIN bracket, without DIN rail
0
3 Note) With DIN bracket, DIN rail for 3 stations
24 Note) With DIN bracket, DIN rail for 24 stations
Note) Specify a longer rail than the length of valve stations.
∗ If the DIN rail must be mounted without an SI Unit, select “D0” and order the
DIN rail separately. Refer to L3 of the dimensions for the DIN rail length.
For the DIN rail part number, refer to the WEB catalog or the SY series
catalog (CAT. ES11-103).
∗ For the fixation of DIN rail mounting type manifold, refer to the WEB catalog
or the SY series catalog (CAT. ES11-103).
Protective class
class # (Mark:
)
18
Series SY3000/5000/7000
How to Order Valves (With mounting screw)
SY 3 1 0 0
q w
5
e r t y u
1
i o !0
!1
Side/Bottom ported
q Series
y Pilot valve option
3
5
7
SY3000
SY5000
SY7000
Nil
B
K Note)
!0 Manual override
Standard (0.7 MPa)
Quick response type (0.7 MPa)
High pressure type (1.0 MPa)
Nil
D
Non-locking
push
Note) Select the metal seal type for high pressure
type.
Push-turn
locking
(slotted)
w Type of actuation
1
2
3
4
5
2-position
3-position
A Note)
4-position dual
B Note) 3-port valve
C Note)
Single
Double
Closed center
Exhaust center
Pressure center
N.C./N.C.
N.O./N.O.
N.C./N.O.
Note) Select the rubber seal type for the 4-position
dual 3-port valve.
e Seal type
0
1
Rubber seal
Metal seal
r Pilot type
Nil
R
Internal pilot
External pilot
u Coil type
Nil
T
Standard
With power saving circuit
(Continuous duty type) Note 1) 2)
Note 1) Be sure to select the power saving circuit
type when the valve is continuously
energized for long periods of time.
Note 2) Be careful of the energizing time when
the power saving circuit is selected. For
details, refer to the WEB catalog or the
SY series catalog (CAT. ES11-103).
i Rated voltage
5
24 VDC
o Light/surge voltage suppressor
and common specification
With light
t Back pressure check valve
Nil
H Note)
None
Built-in
Note) Select the rubber seal type when the
back pressure check valve is built-in.
Manifold installed type is available if the
back pressure check valve is required for
a valve with metal seal. For ordering
example, refer to the WEB catalog or the
SY series catalog (CAT. ES11-103).
However, it is not recommended to use
the built-in valve type and the manifold
installed type at the same time because it
will reduce the flow.
∗ Select “Nil” for 3-position type and the SY7000.
E
R
U
NS
NZ
—
—
Surge voltage Common
suppressor specification
Non-polar
Negative
common
∗ Select “NZ” type for with the power saving
circuit.
Push-turn
locking
(manual)
F
Slide locking
(manual)
!1 Type of mounting screw
Nil
B
K
Round head combination screw
Hexagon socket head cap screw
Round head combination screw
(Falling-out-prevention type) Note)
H
Hexagon socket head cap screw
(Falling-out-prevention type) Note)
Note) For “K” and “H”, the valve body cover has
a drop prevention construction to stop the
mounting screws from falling out when
the valve is removed for maintenance
etc.
∗ When ordering a valve individually, the
base gasket is not included.
Since the base gasket is attached to the
manifold, please order the base gasket
separately if it is needed for maintenance
service.
For details, refer to the WEB catalog or the
SY series catalog (CAT. ES11-103).
∗ Select “Nil” or “K” for the optional individual
SUP/EXH spacer assembly, interface
regulator or double check spacer assembly
with residual pressure release valve.
Protective class
class # (Mark:
19
)
Gateway Decentralized System 2
5 Port Solenoid Valve
Type 12
Top Ported
RoHS
For detailed specifications, Common Precautions and Specific Product Precautions, refer to the WEB catalog or the SY series catalog (CAT. ES11-103).
How to Order Manifold
SS5Y 3 12S A3N 05 U
q
q Series
…
w SI Unit (Number of outputs, Output polarity,
24 24 stations
Note) For type “S”, supply /exhaust block
assembly with built-in silencer, choose
“U” or “D” for P, E port entry.
layout Note 2)
Specified
(Available up to 32 solenoids)
Without SI Unit
32 outputs Note 1, 4), 1 to 16 stations (24
stations Note 3)), Negative common Note 2)
How to Order Manifold Assembly
Nil
S Note 1)
R
Internal pilot
Internal pilot, Built-in silencer Note 2)
External pilot
Note 1) For type “S”, supply/exhaust block
assembly with built-in silencer, choose
“U” or “D” for P, E port entry. 3/5(E)
port is plugged. The silencer exhaust
port is located on the opposite side of
P, E port entry. (Example: When the P,
E port entry is D side, the silencer
exhaust port is U side.)
Note 2) When the built-in silencer type is used,
keep the exhaust port from coming in
direct contact with water or other
liquids.
y P, E port size (One-touch fittings)
2-position double
SY3000
SY5000
SY7000
Nil
ø8
ø10
ø12
N Note)
ø5/16"
ø3/8"
ø1/2"
Note) For “N”, sizes are in inches.
D
si
de
1
2
3
S
ta
Manifold base
SS5Y3-12SA3N-05D ········1 set (Manifold base part number)
∗ SY3230-5U1-C6 ·············5 sets (2-position double part number)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
Nil
D
D0
D3 Note)
Direct mounting
With DIN bracket, DIN rail with standard length
With DIN bracket, without DIN rail
With DIN bracket, DIN rail for 3 stations
…
…
tio
ns
U
si
d
e
u Mounting
D24 Note) With DIN bracket, DIN rail for 24 stations
Note) Specify a longer rail than the length of valve stations.
∗ If the DIN rail must be mounted without an SI Unit, select
“D0”. Then, refer to L3 of the dimensions for the DIN rail
length and order separately. For the DIN rail part number,
refer to the WEB catalog or the SY series catalog (CAT.
ES11-103).
∗ For the fixation of DIN rail mounting type manifold, refer to
the WEB catalog or the SY series catalog (CAT. ES11-103).
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold base part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on the manifold specification sheet.
20
SV
Note 1) 16 outputs can be set by switching the
built-in setting switch.
Note 2) Ensure a match with the common
specification of the valve.
Note 3) ( ): Maximum number of stations for
mixed single and double wiring.
Note 4) When using the SI Unit with 32 outputs,
use the GW Unit compatible with the
EX500 Gateway Decentralized System
2 (128 points).
t SUP/EXH block assembly
S0700
Note 1) Double wiring: 2-position single, double,
3-position and 4-position valves can be
used on all manifold stations. Use of a
2-position single solenoid will result in
an unused control signal. If this is not
desired, order with a specified layout.
Note 2) Specified layout: Indicate the wiring
specifications on the manifold specification
sheet. (Note that 2-position double, 3-position
and 4-position valves cannot be used where
single wiring has been specified.)
Note 3) For the product without the SI Unit (S0), note
the maximum number of solenoids of the SI Unit
that will be mounted. If the layout is specified,
indicate it on the manifold specification sheet.
∗ This also includes the number of blanking
plate assembly.
Max. number of valve stations)
U side (2 to 10 stations)
D side (2 to 10 stations)
Both sides (2 to 24 stations)
VQC
16 16 stations
02 2 stations
…
U Note)
D Note)
B
Double wiring Note 1)
∗ For mixed mounting, refer to the WEB catalog
or the SY series catalog (CAT. ES11-103).
Example
r P, E port entry
Note
…
…
Stations
02 2 stations
y u
SY
SY3000
SY5000
SY7000
A3N
r t
e Valve stations
3
5
7
0
e
w
Gateway Decentralized System 2
Series SY3000/5000/7000
Series SY3000/5000/7000
How to Order Valves (With mounting screw)
SY 3 1 3 0
q w
5
e r t y u
1 C6
i o !0
!1
!2
!3
Top ported
y Pilot valve option
q Series
3
5
7
SY3000
SY5000
SY7000
Nil
B
K Note)
!1 A, B port size
Standard (0.7 MPa)
Quick response type (0.7 MPa)
High pressure type (1.0 MPa)
Note) Select the metal seal type for high pressure
type.
w Type of actuation
1
2
3
4
5
2-position
3-position
A Note)
4-position dual
B Note) 3-port valve
C Note)
u Coil type
Nil
Standard
With power saving circuit
(Continuous duty type) Note 1) 2)
T
Note 1) Be sure to select the power saving circuit
type when the valve is continuously
energized for long periods of time.
Note 2) Be careful of the energizing time when
the power saving circuit is selected. For
details, refer to the SY series catalog
(CAT. ES11-103).
i Rated voltage
e Seal type
Rubber seal
Metal seal
5
24 VDC
o Light/surge voltage suppressor
and common specification
r Pilot type
Nil
R
Internal pilot
External pilot
t Back pressure check valve (Built-in valve type)
Nil
H Note)
M5
01
02
Port size
M5 x 0.8
1/8
1/4
SY3000 SY5000 SY7000
—
—
—
—
—
—
One-touch fitting (Metric)
Single
Double
Closed center
Exhaust center
Pressure center
N.C./N.C.
N.O./N.O.
N.C./N.O.
Note) Select the rubber seal type for the 4-position
dual 3-port valve.
0
1
Thread piping
None
Built-in
Note) Select the rubber seal type when the
back pressure check valve is built-in.
Manifold installed type is available if the
back pressure check valve is required for
a valve with metal seal. For ordering
example, refer to the SY series catalog
(CAT. ES11-103). However, it is not
recommended to use the built-in valve
type and the manifold installed type at
the same time because it will reduce the
flow.
∗ Select “Nil” for 3-position type and the SY7000.
With light
R
U
NS
NZ
Surge voltage Common
suppressor specification
—
—
Non-polar
Negative
common
∗ Select “NZ” type for with the power saving
circuit.
Nil
E
Push-turn
locking
(manual)
D
Push-turn
locking
(slotted)
F
Slide locking
(manual)
A, B port
ø2
ø3.2
ø4
ø6
ø8
ø10
ø12
SY3000 SY5000 SY7000
—
—
—
—
—
—
—
—
—
—
One-touch fitting (Inch)
N1
N3
N7
N9
N11
A, B port
ø1/8"
ø5/32"
ø1/4"
ø5/16"
ø3/8"
SY3000 SY5000 SY7000
—
—
—
—
—
—
!2 A, B port thread type
Nil
F
N
T
Rc
G
NPT
NPTF
∗ Select “Nil” for M5.
!3 Type of mounting screw
Nil
B
!0 Manual override
Non-locking
push
C2
C3
C4
C6
C8
C10
C12
K
Round head combination screw
Hexagon socket head cap screw
Round head combination screw
(Falling-out-prevention type Note))
H
Hexagon socket head cap screw
(Falling-out-prevention type Note))
Note) For “K” and “H”, the valve body cover has
a drop prevention construction to stop the
mounting screws from falling out when
the valve is removed for maintenance
etc.
∗ When ordering a valve individually, the
base gasket is not included.
Since the base gasket is attached to the
manifold, please order the base gasket
separately if it is needed for maintenance
service.
For details, refer to the SY series catalog
(CAT. ES11-103).
∗ Select “Nil” or “K” for the optional individual
SUP/EXH spacer assembly or interface
regulator.
Protective class
class # (Mark:
21
)
Gateway Decentralized System 2
5 Port Solenoid Valve
Series SY3000
Series SY3000
Type 10/Side Ported
Dimensions
D side
U side
Gateway Decentralized System 2
Light/surge voltage suppressor
Manual override
4(A) port side: Blue (for rubber seal)
: Gray (for metal seal)
2(B) port side: Yellow
L1
(5.5)
(L5)
(8)
12 B
12 B
12 B
12 B
12 B
(40.9)
1.7
4.6
(4.9)
)
21.2
C6: 3.6
N7: 7.4
(
4 x M4 Mounting hole
L2
(Fitting for the type with P/E ports on the U and/or D sides)
1.5
(L4)
(DIN rail mounting hole pitch: 12.5)
(5.3)
VQC
(L3)
(Station 1)
(Station n)
M12
S0700
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: ø8, ø5/16"
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
: ø6, ø1/4"
SV
B2
B
A4
A4
A
3/5
E
11.3
46.5
15.5
(Pitch)
P = 10.5
(7.5)
M12
(11.8)
B2
A4
63.1
B2
A4
21.6
B2
4
18
40.2
2
56.6
E
P
13.6
3/5
1
10.6
P
IN
25.6
76.7
67.2
46.2
OUT
1
(17.8)
Note) These figures show the “SS5Y3-10SA3N-05D-C6”.
L: Dimensions
n
L
L1
L2
L3
L4
L5
n
L
L1
L2
L3
L4
L5
n: Stations
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
103.7
114.2
124.7
135.2
145.7
156.2
166.7
177.2
187.7
198.2
208.7
219.2
229.7
240.2
250.7
63
73.5
84
94.5
105
115.5
126
136.5
147
157.5
168
178.5
189
199.5
210
135.5
148
148
160.5
173
185.5
198
210.5
223
223
235.5
248
260.5
273
285.5
125
137.5
137.5
150
162.5
175
187.5
200
212.5
212.5
225
237.5
250
262.5
275
16
17
11.5
17.5
12.5
12.5
13.5
14.5
15.5
SY
SI Unit
83
14 A
92.6
14 A
60.5
14 A
4.6
14 A
80.2
14 A
(35)
B A B A B A B A B A
16.5
17
18
19
20
21
22
23
24
261.2
271.7
282.2
292.7
303.2
313.7
324.2
334.7
220.5
231
241.5
252
262.5
273
283.5
294
285.5
298
310.5
323
335.5
348
348
360.5
275
287.5
300
312.5
325
337.5
337.5
350
12
13
14
15
16
17
12
13
13.5
14.5
15.5
16.5
17.5
For dimensions of Type 11/Bottom ported type
and Type 12/Top ported type, refer to the WEB
catalog or the SY series catalog (CAT. ES11103).
22
Series SY5000
Type 10/Side Ported
Dimensions
D side
Series SY5000
U side
Light/surge voltage suppressor
Manual override
4(A) port side: Blue (for rubber seal)
: Gray (for metal seal)
2(B) port side: Yellow
14 A
12 B
12 B
12 B
12 B
12 B
34.2
L2
1.5
(L4)
(DIN rail mounting hole pitch: 12.5)
(5.3)
(61.7)
4.7
5.5
(5.9)
SI Unit
(8.3)
0.4
101
14 A
B A
14 A
97.5
14 A
B A
14 A
81.2
B A
10.9
B A
(35)
(8)
B A
113.4
L1
(5.5)
(L5)
4 x M5 Mounting hole
(Fitting for the type with P/E ports on the U and/or D sides)
(L3)
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: ø10, ø3/8"
(Station 1)
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"
(Station n)
M12
8.7
48.2
18
A4
A4
A4
1
P
3/5
E
B
A
(Pitch)
P = 16
(11.8)
B2
73.2
B2
(7.5)
25.6
A4
11.3
M12
B2
E
4
12.4
46.2
3/5
B2
56.6
2
14.1
P
29.1
1
IN
33.4
76.7
67.2
OUT
(20.5)
Note) These figures show the “SS5Y5-10SA3N-05D-C8”.
L: Dimensions
n
L
L1
L2
L3
L4
L5
n
L
L1
L2
L3
L4
L5
23
n: Stations
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
120.7
136.7
152.7
168.7
184.7
200.7
216.7
232.7
248.7
264.7
280.7
296.7
312.7
328.7
344.7
80
96
112
128
144
160
176
192
208
224
240
256
272
288
304
148
160.5
185.5
198
210.5
235.5
248
260.5
273
298
310.5
323
348
360.5
373
137.5
150
175
187.5
200
225
237.5
250
262.5
287.5
300
312.5
337.5
350
362.5
13.5
12
14.5
13
15.5
14
12
16.5
15
13
17.5
16
14
16.5
17.5
17
18
19
20
21
22
23
24
360.7
376.7
392.7
408.7
424.7
440.7
456.7
472.7
320
336
352
368
384
400
416
432
385.5
410.5
423
435.5
448
473
485.5
498
375
400
412.5
425
437.5
462.5
475
487.5
17
15
11.5
16
12.5
13.5
14.5
12.5
For dimensions of Type 11/Bottom ported type
and Type 12/Top ported type, refer to the WEB
catalog or the SY series catalog (CAT. ES11103).
Gateway Decentralized System 2
Series SY7000
5 Port Solenoid Valve
Series SY7000
Type 10/Side Ported
Dimensions
D side
U side
Gateway Decentralized System 2
Light/surge voltage suppressor
(L5)
Manual override
4(A) port side: Blue (for rubber seal)
: Gray (for metal seal)
2(B) port side: Yellow
L1
B A
B A
B A
14 A
14 A
14 A
12 B
12 B
12 B
12 B
12 B
115
96.7
(77.1)
(5.5)
5.5
34.4
(A, B port: ø12)
1.5
(L4)
(DIN rail mounting hole pitch: 12.5)
(5.3)
3.9
4 x M5 Mounting hole
L2
(Fitting for the type with P/E ports on the U and/or D sides)
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: ø12, ø1/2"
(Station 1)
S0700
(L3)
2
M12
SV
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
: ø10, ø3/8"
: ø12
(Station n)
B2
B2
B
A4
A4
A4
A
E
1
P
3/5
E
(14.3)
A4
B2
82.7
4
S
56.6
B2
11.3
M12
53.2
20.5
(Pitch)
P = 19
(10)
8.7
25.6
14.2
46.2
35.2
3/5
2
11.1
P
31.6
1
67.2
76.7
OUT
IN
21.7
Note) These figures show the “SS5Y7-10SA3N-05D-C10”.
L: Dimensions
n
L
L1
L2
L3
L4
L5
n
L
L1
L2
L3
L4
L5
n: Stations
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
134.9
153.9
172.9
191.9
210.9
229.9
248.9
267.9
286.9
305.9
324.9
343.9
362.9
381.9
400.9
94
113
132
151
170
189
208
227
246
265
284
303
322
341
360
160.5
185.5
198
223
235.5
260.5
273
298
310.5
335.5
348
373
398
410.5
435.5
150
175
187.5
212.5
225
250
262.5
287.5
300
325
337.5
362.5
387.5
400
425
13
16
12.5
15.5
12
15
12
15
11.5
14.5
17.5
12.5
15.5
17
18
19
20
21
22
23
24
419.9
438.9
457.9
476.9
495.9
514.9
533.9
552.9
379
398
417
436
455
474
493
512
448
473
485.5
510.5
523
548
560.5
585.5
437.5
462.5
475
500
512.5
537.5
550
575
14
17
14
17
13.5
16.5
13.5
16.5
14.5
VQC
(9.3)
(N13: 20.4)
(6)
(17.9)
SI Unit
SY
8.8
15
128.8
B A
14 A
101.4
B A
14 A
(35)
(8)
17.5
For dimensions of Type 11/Bottom ported type
and Type 12/Top ported type, refer to the WEB
catalog or the SY series catalog (CAT. ES11103).
24
Gateway Decentralized System 2
5 Port Solenoid Valve
Series VQC1000
For detailed specifications, Common Precautions and Specific Product Precautions, refer to the WEB catalog or the VQC1000/2000 series catalog (CAT. ES11-101).
How to Order Manifold
VV5QC 1 1 12 C6 SDA3 N
q
q Valve stations
…
…
12 12 stations
01 1 station
24 24 stations
e
r
t
e SI Unit (Number of outputs, Max. number of valve stations)
Note
…
…
Stations
01 1 station
w
Double wiring
Mixed wiring, Specified layout Note)
(Available up to 24 solenoids)
SD0
SDA3
Without SI Unit
32 outputs Note 1, 3), 1 to 12 stations (24 stations Note 2))
Note 1) Due to the internal wiring of the valve, the maximum number of outputs is 24 points.
16 outputs can be set by switching the built-in setting switch.
Note 2) ( ): Maximum number of stations for mixed single and double wiring.
Note 3) When using the SI Unit with 32 outputs, use the GW Unit compatible with the EX500 Gateway
Decentralized System 2 (128 points).
Note) Specified layout: Indicate the wiring
specifications on the manifold specification sheet. (Note that 2-position double,
3-position and 4-position valves cannot
be used where single wiring has been
specified.) In addition, select the option
“K”.
w A, B port size
Metric size
C3
C4
C6
M5
CM Note 1)
L3
L4
L6
L5
B3
B4
B6
B5
LM Note 1)
MM Note 2)
Straight piping: ø3.2 One-touch fitting
Straight piping: ø4 One-touch fitting
Straight piping: ø6 One-touch fitting
Straight piping: M5 thread
Straight piping: Mixed sizes and with port plug
Top ported elbow: ø3.2 One-touch fitting
Top ported elbow: ø4 One-touch fitting
Top ported elbow: ø6 One-touch fitting
Top ported elbow: M5 thread
Bottom ported elbow: ø3.2 One-touch fitting
Bottom ported elbow: ø4 One-touch fitting
Bottom ported elbow: ø6 One-touch fitting
Bottom ported elbow: M5 thread
Elbow piping: Mixed sizes and with port plug
Mixed size for different types of piping, option installed
Inch size
N1
N3
N7
NM Note1)
LN1
LN3
LN7
BN1
BN3
BN7
LNM Note1)
BNM Note 2)
Straight piping: ø1/8" One-touch fitting
Straight piping: ø5/32" One-touch fitting
Straight piping: ø1/4" One-touch fitting
Straight piping: Mixed sizes and with port plug
Top ported elbow: ø1/8" One-touch fitting
Top ported elbow: ø5/32" One-touch fitting
Top ported elbow: ø1/4" One-touch fitting
Bottom ported elbow: ø1/8" One-touch fitting
Bottom ported elbow: ø5/32" One-touch fitting
Bottom ported elbow: ø1/4" One-touch fitting
Elbow piping: Mixed sizes and with port plug
Mixed size for different types of piping, option installed
Note 1) Indicate the sizes on the manifold
specification sheet.
Note 2) When a combination of straight and
elbow piping is or when option such as
dual flow fitting assembly is mounted,
please mention the mounting conditions
in the Manifold Specification.
25
r SI Unit (Output polarity)
Nil
N
(Without SI Unit)
Negative common
∗ Ensure a match with the common
specification of the valve to be used.
t Option
Nil
B Note 1)
D
D0
D Note 2)
K Note 3)
N
R Note 4)
S Note 5)
None
With back pressure check valve (All stations)
With DIN bracket, DIN rail with standard length
With DIN bracket, without DIN rail
With DIN bracket, DIN rail for stations
Special wiring specification (Except double wiring)
With name plate
External pilot
Built-in silencer, Direct exhaust
∗ When multiple symbols are specified, indicate
them alphabetically. Example) -BRS
Note 1) When a back pressure check valve is
used only for specified station, specify
the back pressure check valve part
number, and specify the station number
to which the valve is mounted, on the
manifold specification sheet.
Note 2) : Specify a longer rail than the length
of valve stations.
Example) “-D08”
In this case, the valves will be mounted
on the DIN rail for 8 stations, regardless
of the number of manifold stations.
Note 3) When single wiring and double wiring
are mixed, specify wiring type of each
station on the manifold specification
sheet.
Note 4) For external pilot option “-R”, indicate
the external pilot specification “R” for
the applicable valves as well.
Note 5) Built-in silencer type does not satisfy
IP67.
Gateway Decentralized System 2
5 Port Solenoid Valve
Series VQC1000
How to Order Valves
A
B C
A Type of actuation
1
D E F
F Manual override
B Seal type
1
2-position single
A Note)
2
2-position double
B Note)
3
3-position closed center
C Note)
4
5
3-position exhaust center
3-position pressure center
0
1
4-position dual 3-port valve
(N.C./N.C.)
4-position dual 3-port valve
(N.O./N.O.)
4-position dual 3-port valve
(N.C./N.O.)
Gateway Decentralized System 2
VQC 1 1 0 0 N 5
Metal seal
Rubber seal
C Function
Negative common,
Standard (0.4 W)
Negative common, Quick
response type (0.95 W)
N
BN
Note) Only rubber seal type
Negative common, High pressure
KN Note 1) type (1.0 MPa, 0.95 W)
B
Locking
push
(tool required)
SY
Negative common,
Nil
Non-locking
push
(tool required)
NR Note 2) External pilot
Note 1) 2)
Negative common, High
KNR pressure type (1.0 MPa,
VQC
0.95 W), External pilot
C
Turn locking
(manual)
S0700
Note 1) For “KN” or “KNR” high
pressure type, select “0”
metal seal.
Note 2) For “NR” or “KNR” external
pilot, select “1” to “5”.
4-position dual 3-port
valve is unavailable.
D
Slide locking (manual)
SV
D Coil voltage
5
24 VDC
E Light/surge voltage
suppressor
Nil
With light/surge voltage suppressor
How to Order Manifold Assembly
Example
2-position single
2-position double
VV5QC11-04C6SDA3N ······1 set (Manifold base part number)
∗ VQC1100N-51··················2 sets (2-position single part number)
∗ VQC1200N-51··················2 sets (2-position double part number)
D
si
de
1
2
3
4
S
ta
tio
ns
U
si
de
Manifold base
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold base part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on the manifold specification sheet.
26
Series VQC1000
Dimensions
L2
L1
42.5
(Pitch)
P = 10.5
(12)
28
Indicator
light
1.5
4 x M4 Mounting hole
1.5
2
63.5
A B
A B
A
A
Manual override
(L3)
(DIN rail mounting hole pitch: 12.5)
SI Unit
66
(5.5)
(2)
(40)
90.9
75
A B
(35)
A B
101.4
93.5
(8)
(5.25)
(L4)
D side Station
1
2
3
4
5
6
n
7
U side
One-touch fitting
[1(P), 3(R) port]
Applicable tube O.D. C8: ø8
N9: ø5/16"
M12
OUT
B
B
B
B
12
P
A
A
A
A
A
1
13
7.5
A
18.5
P
M12
56.9
13.4
62.5
B
40.5
B
25
B
9.5
46.2
X
X
1 A
(7.5)
3
3
12
25.6
76.7
67.2
IN
58.7
R
R
20.5
M5 x 0.8
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø3.2, ø1/8"
ø4, ø5/32"
ø6, ø1/4"
L: Dimensions
n
L
L1
L2
L3
L4
n
L
L1
L2
L3
L4
27
1
n: Stations
2
3
4
5
55.5
66
76.5
87
97.5
104.2
114.7
125.2
135.7
125
137.5
150
162.5
135.5
148
160.5
173
16
17
18
19
6
7
8
9
10
11
12
13
14
15
108
118.5
129
139.5
150
160.5
171
181.5
192
202.5
146.2
156.7
167.2
177.7
188.2
198.7
209.2
219.7
230.2
240.7
251.2
175
187.5
187.5
200
212.5
225
237.5
250
250
262.5
275
185.5
198
198
210.5
223
235.5
248
260.5
260.5
273
285.5
20
21
22
23
24
213
223.5
234
244.5
255
265.5
276
286.5
297
261.7
272.2
282.7
293.2
303.7
314.2
324.7
335.2
345.7
287.5
300
312.5
325
325
337.5
350
362.5
375
298
310.5
323
335.5
335.5
348
360.5
373
385.5
Gateway Decentralized System 2
5 Port Solenoid Valve
For detailed specifications, Common Precautions and Specific Product Precautions, refer to the WEB catalog or the VQC1000/2000 series catalog (CAT. ES11-101).
How to Order Manifold
VV5QC 2 1 12 C8 SDA3 N
q
q Valve stations
…
t
e SI Unit (Number of outputs, Max. number of valve stations)
Note
…
…
24 24 stations
r
Double wiring
Mixed wiring, Specified layout Note)
(Available up to 24 solenoids)
SD0
SDA3
Without SI Unit
32 outputs Note 1, 3), 1 to 12 stations (24 stations Note 2))
Note 1) Due to the internal wiring of the valve, the maximum number of outputs is 24 points.
16 outputs can be set by switching the built-in setting switch.
Note 2) ( ): Maximum number of stations for mixed single and double wiring.
Note 3) When using the SI Unit with 32 outputs, use the GW Unit compatible with the EX500 Gateway
Decentralized System 2 (128 points).
Metric size
C4
C6
C8
CM Note1)
L4
L6
L8
B4
B6
B8
LM Note1)
MM Note2)
Straight piping: ø4 One-touch fitting
Straight piping: ø6 One-touch fitting
Straight piping: ø8 One-touch fitting
Straight piping: Mixed sizes and with port plug
Top ported elbow: ø4 One-touch fitting
Top ported elbow: ø6 One-touch fitting
Top ported elbow: ø8 One-touch fitting
Bottom ported elbow: ø4 One-touch fitting
Bottom ported elbow: ø6 One-touch fitting
Bottom ported elbow: ø8 One-touch fitting
Elbow piping: Mixed sizes and with port plug
Mixed size for different types of piping, option installed
Inch size
N1
N3
N7
NM Note1)
LN1
LN3
LN7
BN1
BN3
BN7
LNM Note1)
BNM Note 2)
Straight piping: ø1/8" One-touch fitting
Straight piping: ø5/32" One-touch fitting
Straight piping: ø1/4" One-touch fitting
Straight piping: Mixed sizes and with port plug
Top ported elbow: ø1/8" One-touch fitting
Top ported elbow: ø5/32" One-touch fitting
Top ported elbow: ø1/4" One-touch fitting
Bottom ported elbow: ø1/8" One-touch fitting
Bottom ported elbow: ø5/32" One-touch fitting
Bottom ported elbow: ø1/4" One-touch fitting
Elbow piping: Mixed sizes and with port plug
Mixed size for different types of piping, option installed
Note 1) Indicate the sizes on the manifold
specification sheet.
Note 2) When a combination of straight and
elbow piping is or when option such as
dual flow fitting assembly is mounted,
please mention the mounting conditions
in the Manifold Specification.
r SI Unit (Output polarity)
Nil
N
(Without SI Unit)
Negative common
∗ Ensure a match with the common
specification of the valve to be used.
SV
w A, B port size
S0700
Note) Specified layout: Indicate the wiring
specifications on the manifold specification sheet. (Note that 2-position double,
3-position and 4-position valves cannot
be used where single wiring has been
specified.) In addition, select the option
“K”.
VQC
…
12 12 stations
01 1 station
e
SY
Stations
01 1 station
w
Gateway Decentralized System 2
Series VQC2000
t Option
Nil
B Note 1)
D
D0
D Note 2)
K Note 3)
N
R Note 4)
S Note 5)
T Note 6)
None
With back pressure check valve (All stations)
With DIN bracket, DIN rail with standard length
With DIN bracket, without DIN rail
With DIN bracket, DIN rail for stations
Special wiring specification (Except double wiring)
With name plate
External pilot
Built-in silencer, Direct exhaust
P and R ports included on both sides of the U side
∗ When multiple symbols are specified, indicate
them alphabetically. Example) -BRS
Note 1) When a back pressure check valve is
used only for specified station, specify
the back pressure check valve part
number, and specify the station number
to which the valve is mounted, on the
manifold specification sheet.
Note 2) : Specify a longer rail than the length
of valve stations.
Example) “-D08”
In this case, the valves will be mounted
on the DIN rail for 8 stations, regardless
of the number of manifold stations.
Note 3) When single wiring and double wiring
are mixed, specify wiring type of each
station on the manifold specification
sheet.
Note 4) For external pilot option “-R”, indicate
the external pilot specification “R” for
the applicable valves as well.
Note 5) Built-in silencer type does not satisfy
IP67.
Note 6) P and R ports are included on both
sides of U side (cylinder port and coil
side) with ø12 One-touch fittings.
28
Series VQC2000
How to Order Valves
VQC 2 1 0 0 N 5
A
B C
A Type of actuation
1
D E F
F Manual override
B Seal type
1
2-position single
A Note)
2
2-position double
B Note)
3
3-position closed center
C Note)
4
5
3-position exhaust center
3-position pressure center
0
1
4-position dual 3-port valve
(N.C./N.C.)
4-position dual 3-port valve
(N.O./N.O.)
4-position dual 3-port valve
(N.C./N.O.)
Metal seal
Rubber seal
C Function
Negative common,
Standard (0.4 W)
Negative common, Quick
response type (0.95 W)
N
BN
Note) Only rubber seal type
Negative common, High pressure
KN Note 1) type (1.0 MPa, 0.95 W)
Nil
Non-locking
push
(tool required)
B
Locking push
(tool required)
Negative common,
NR Note 2) External pilot
Note 1) 2)
Negative common, High
KNR pressure type (1.0 MPa,
0.95 W), External pilot
Note 1) For “KN” or “KNR” high
pressure type, select “0”
metal seal.
Note 2) For “NR” or “KNR” external
pilot, select “1” to “5”.
4-position dual 3-port
valve is unavailable.
C
Turn locking
(manual)
D
Slide locking
(manual)
D Coil voltage
5
24 VDC
E Light/surge voltage
suppressor
Nil
With light/surge voltage suppressor
How to Order Manifold Assembly
Example
2-position single
2-position double
VV5QC21-04C6SDA3N ······1 set (Manifold base part number)
∗ VQC2100N-51··················2 sets (2-position solenoid part number)
∗ VQC2200N-51··················2 sets (2-position double part number)
1
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
D
si
de
2
3
4
S
ta
tio
ns
U
si
de
Manifold base
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold base part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on the manifold specification sheet.
29
Gateway Decentralized System 2
Series VQC2000
5 Port Solenoid Valve
Dimensions
L2
(Pitch)
P = 16
1
4 x M5 Mounting hole
1.3
(10.5)
Indicator
light
1
74
(Double sided type)
38.5
0.9
(12)
Gateway Decentralized System 2
L1
38.5
120
105.5
80
91.7
(35)
(53.5)
(5.5)
90.9
101.4
(8)
(5.5)
(3.5)
SY
SI Unit
Manual override
(L3)
(DIN rail mounting hole pitch: 12.5)
VQC
(5.25)
(L4)
M12
Station
1
2
3
4
5
6
n
7
U side
(
57.2
R
)
R
B
B
B
B
P
P
12
1
A
A
A
A
A
1
13
(7.5)
10
A
M12
21.5
13.5
A
30
B
49.5
X
B
76.5
3
B
25
25.6
12
72
3
X
IN
46.2
76.7
67.2
OUT
25
55
18
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
L: Dimensions
n
L
L1
L2
L3
L4
n
L
L1
L2
L3
L4
n: Stations
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
73
89
105
121
137
153
169
185
201
217
233
249
265
281
297
118
134
150
166
182
198
214
230
246
262
278
294
310
326
342
137.5
162.5
175
187.5
212.5
225
237.5
250
275
287.5
300
325
337.5
350
362.5
148
173
185.5
198
223
235.5
248
260.5
285.5
298
310.5
335.5
348
360.5
373
16
17
18
19
20
21
22
23
24
313
329
345
361
377
393
409
425
441
358
374
390
406
422
438
454
470
486
387.5
400
412.5
437.5
450
462.5
475
500
512.5
398
410.5
423
448
460.5
473
485.5
510.5
523
30
SV
One-touch fitting
[1(P), 3(R) port]
Applicable tube O.D. C10: ø10
N11: ø3/8"
C12: ø12
(Double sided type)
S0700
D side
Gateway Decentralized System 2
5 Port Solenoid Valve
Series VQC4000
For detailed specifications, Common Precautions and Specific Product Precautions, refer to the WEB catalog or the VQC4000/5000 series catalog (CAT. ES11-108).
How to Order Manifold
VV5QC 4 1 12 02
q
q Valve stations
Note
…
…
…
…
16 16 stations
e
r
t
y
r SI Unit (Number of outputs, Max. number of valve stations)
Stations
01 1 station
12 12 stations
01 1 station
w
SDA3 N
Double wiring
Mixed wiring, Specified layout Note)
(Available up to 24 solenoids)
SD0
SDA3
Without SI Unit
32 outputs Note 1, 3), 1 to 12 stations (16 stations Note 2))
Note 1) Due to the internal wiring of the valve, the maximum number of
outputs is 24 points.
Note 2) ( ): Maximum number of stations for mixed single and double wiring.
Note 3) When using the SI Unit with 32 outputs, use the GW Unit compatible
with the EX500 Gateway Decentralized System 2 (128 points).
Note) Specified layout: Indicate the wiring specifications on the manifold specification
sheet. (Note that 2-position double,
3-position and 4-position valves cannot
be used where single wiring has been
specified.) In addition, select the option
“K”.
w Cylinder port size
C6
C8
C10
C12
N7
N9
N11
02
03
B
CM
With ø6 One-touch fitting
With ø8 One-touch fitting
With ø10 One-touch fitting
With ø12 One-touch fitting
ø1/4" One-touch fitting
ø5/16" One-touch fitting
ø3/8" One-touch fitting
1/4 Note)
3/8 Note)
Bottom ported 1/4 Note)
Mixed sizes
Note) Compatible with Rc, G, NPT/NPTF.
Part number displayed is as shown below.
e Thread type
Nil
F
N
T
31
Rc
G
NPT
NPTF
t SI Unit (Output polarity)
Nil
N
(Without SI Unit)
Negative common
y Option
Nil None
K Note) Special wiring specification (Except double wiring)
Note) When single wiring and double wiring are
mixed, specify wiring type of each station
on the manifold specification sheet.
Gateway Decentralized System 2
5 Port Solenoid Valve
Series VQC4000
How to Order Valves
A
5
B C
A Type of actuation
1
2
3
2-position single
2-position double
3-position closed center
D E F
C Function
4
5
6 Note)
F Manual override
Nil Note 1) Standard (0.95 W)
Low wattage type (0.4 W)
Y
External pilot
R Note 2)
3-position exhaust center
3-position pressure center
3-position double check
B Seal type
Metal seal
Rubber seal
Nil
Non-locking
push
(tool required)
B
SY
Locking push
(tool required)
VQC
∗ When multiple symbols are specified, indicate them alphabetically.
Note 1) When the power is energized continuously, refer to
“Specific Product Precautions 1” in the WEB catalog
or the VQC4000/5000 series catalog (CAT. ES11108).
Note 2) For details about the external pilot type, refer to the
WEB catalog or the
VQ4000/5000 series catalog (CAT. ES11-104). In addition, an external pilot type
cannot be combined with
the double check spacer.
Note) For double check type, refer to the WEB catalog or the VQ4000/5000
series catalog (CAT. ES11-104).
0
1
1
Gateway Decentralized System 2
VQC 4 1 0 0
S0700
D Coil voltage
5
24 VDC
SV
E Light/surge voltage
C
Turn locking
(manual)
suppressor
Nil
E
With
Without light, with surge
voltage suppressor
How to Order Manifold Assembly
Example
2-position single
VV5QC41-04C8SDA3N······1 set (Manifold base part number)
∗ VQC4100-51····················4 sets (2-position single part number)
D
si
1
de
2
3
4
V
al
ve
st
at
io
ns
U
si
de
Manifold base
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold base part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on the manifold specification sheet.
32
Series VQC4000
Dimensions
Indicator light
D side
Manual override
U side
L2
L1
B
A
B
B
A
A
A
B
B
A
A
A
A
9
90.9
143
A
B
A
B
163
9
A
43.9
B
101.4
(6.5)
A
39.5
10
SI Unit
(Station 1)
3/4"
3(R) port
(Station n)
1/2"
1(P) port
M12
B 2
B 2
B 2
B 2
B 2
B
4
A 4
A 4
A 4
A 4
A 4
A 4
A
1
P
12
11.5
15.7
12 X
M12
1/8"
External pilot port
20.6
PE
PE
X 12
1/8"
PE port
95.5
B 2
101.2
2
IN
42.7
76.7
1
R
77.3
P
OUT
3
3
43.5
R
27.9
33.5
37.5
45.2
1/4",3/8"
C6, C8, C10, C12, N7, N9, N11
4(A),2(B) port
Formula: L1 = 25n + 106, L2 = 25n + 152 n: Stations (Maximum 16 stations)
n
L
L1
L2
33
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
131
156
181
206
231
256
281
306
331
356
381
406
431
456
481
506
177
202
227
252
277
302
327
352
377
402
427
452
477
502
527
552
Gateway Decentralized System 2
5 Port Solenoid Valve
For detailed specifications, Common Precautions and Specific Product Precautions, refer to the WEB catalog or the VQC4000/5000 series catalog (CAT. ES11-108).
How to Order Manifold
VV5QC 5 1 12 03
q
q Valve stations
Note
…
…
…
t
y
Double wiring
Mixed wiring, Specified layout Note)
(Available up to 24 solenoids)
SD0
SDA3
Without SI Unit
32 outputs Note 1, 3), 1 to 12 stations (16 stations Note 2))
Note 1) Due to the internal wiring of the valve, the maximum number of
outputs is 24 points.
Note 2) ( ): Maximum number of stations for mixed single and double wiring.
Note 3) When using the SI Unit with 32 outputs, use the GW Unit compatible
with the EX500 Gateway Decentralized System 2 (128 points).
VQC
…
r
SY
16 16 stations
e
r SI Unit (Number of outputs, Max. number of valve stations)
Stations
01 1 station
12 12 stations
01 1 station
w
SDA3 N
Gateway Decentralized System 2
Series VQC5000
S0700
Note) Specified layout: Indicate the wiring specifications on the manifold specification
sheet. (Note that 2-position double,
3-position and 4-position valves cannot
be used where single wiring has been
specified.) In addition, select the option
“K”.
SV
w Cylinder port size
03
04
B
CM
3/8 Note)
1/2 Note)
Bottom ported 1/4 Note)
Mixed sizes
Note) Compatible with Rc, G, NPT/NPTF.
Part number displayed is as shown below.
t SI Unit (Output polarity)
Nil
N
(Without SI Unit)
Negative common
y Option
Nil None
K Note) Special wiring specification (Except double wiring)
Note) When single wiring and double wiring are
mixed, specify wiring type of each station
on the manifold specification sheet.
e Thread type
Nil
F
N
T
Rc
G
NPT
NPTF
34
Series VQC5000
How to Order Valves
VQC 5 1 0 0
A
B C
A Type of actuation
1
2
3
2-position single
2-position double
3-position closed center
1
D E F
C Function
4
5
6 Note)
F Manual override
Nil Note 1) Standard (0.95 W)
Low wattage type (0.4 W)
Y
External pilot
R Note 2)
3-position exhaust center
3-position pressure center
3-position double check
∗ When multiple symbols are specified, indicate them alphabetically.
Note 1) When the power is energized continuously, refer to
“Specific Product Precautions 1” in the WEB catalog
or the VQC4000/5000 series catalog (CAT. ES11108).
Note 2) For details about the external pilot type, refer to the
WEB catalog or the
VQ4000/5000 series catalog (CAT. ES11-104). In addition, an external pilot type
cannot be combined with
the double check spacer.
Note) For double check type, refer to the WEB catalog or the VQ4000/5000
series catalog (CAT. ES11-104).
B Seal type
0
1
5
Metal seal
Rubber seal
Nil
Non-locking
push
(tool required)
B
Push-turn locking
(tool required)
D Coil voltage
5
24 VDC
E Light/surge voltage
C
Turn locking
(manual)
suppressor
Nil
With
Without light, with surge
voltage suppressor
E
How to Order Manifold Assembly
Example
2-position double
U
si
d
e
2-position single
VV5QC51-0603SDA3N······ 1 set
∗ VQC5100-51··················· 2 sets (2-position single part number)
∗ VQC5200-51··················· 2 sets (2-position double part number)
∗ VQC5300-51··················· 3 sets (3-position closed center part number)
1
D
si
de
2
3
4
5
6
V
al
ve
st
at
io
ns
Manifold base
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold base part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on the manifold specification sheet.
35
Gateway Decentralized System 2
Series VQC5000
5 Port Solenoid Valve
Dimensions
Indicator light
10
107.8
29.5 29.5
106
9
5 R1
B
1 P
B
179
A
A
A
A
A
B
3 R2
PE
9
61
A
B
12
19
SI Unit
SY
184.5 (3-position: Metal seal type)
A B
A B
B
179 (Single, Double, 3-position: Rubber seal type)
P = 41
A B
59.5
A B
35.2
Gateway Decentralized System 2
Manual override
L2
L1
21
47.5
VQC
3/4"
1(P), 5(R1), 3(R2) port
1/8"
PE. port
1
Station
2
3
4
5
n
6
B
2
B
2
B
4
A
4
A
4
A
4
A
4
A
4
17
12 X
A
34
34.5
69.5
41
3/8", 1/2"
4(A), 2(B) port
1/2"
1(P) port
69
2
51
B
55.5
2
22
B
15.5
2
1
19
60
53.7
B
SV
2
117
M5 x 0.8 Ground screw
3
Communication connector C2
(M12 Male thread)
U side
S0700
D side
1/2"
3(R) port
Communication connector C1
(M12 Female thread)
1/8"
External pilot port
48
68.5
Formula: L1 = 41n + 77, L2 = 41n + 122 n: Stations (Maximum 12 stations)
n
L
L1
L2
1
2
3
4
5
6
7
8
9
10
11
12
118
159
200
241
282
323
364
405
446
487
528
569
163.2
204.2
245.2
286.2
327.2
368.2
409.2
450.2
491.2
532.2
573.2
614.2
36
Gateway Decentralized System 2
5 Port Solenoid Valve
Series S0700
For detailed specifications, Common Precautions and Specific Product Precautions, refer to the WEB catalog or the S0700 series catalog (CAT. ES11-88).
How to Order Manifold
SS0750 08 C4 C8 SDA3 N B
q
q Valve stations
…
…
16 16 stations
01 1 station
24 24 stations
e
r
t
y
r SI Unit (Number of outputs, Max. number of valve stations)
Note
…
…
Stations
01 1 station
w
Double wiring
Mixed wiring, Specified layout Note)
(Available up to 32 solenoids)
0
SDA3
Without SI Unit
32 outputs Note 1, 3), 1 to 16 stations (24 stations Note 2))
Note 1) 16 outputs can be set by switching the built-in setting switch.
Note 2) ( ): Maximum number of stations for mixed single and double wiring.
Note 3) When using the SI Unit with 32 outputs, use the GW Unit compatible
with the EX500 Gateway Decentralized System 2 (128 points).
Note) Specified layout: Indicate the wiring
specifications on the manifold specification sheet. (Note that 2-position double,
3-position and 4-position valves cannot
be used where single wiring has been
specified.) In addition, select the option
“K”.
w A, B port size
Metric size
C2
C3
C4
CM Note)
ø2 One-touch fitting
ø3.2 One-touch fitting
ø4 One-touch fitting
Mixed sizes and with port plug
Inch size
N1
N3
NM Note)
ø1/8" One-touch fitting
ø5/32" One-touch fitting
Mixed sizes and with port plug
Note) Indicate the sizes on the manifold
specification sheet.
e P, R port size
Metric size
Nil
C6
C8
ø8 One-touch fitting Note)
ø6 One-touch fitting
ø8 One-touch fitting
Inch size
N7
N9
ø1/4" One-touch fitting
ø5/16" One-touch fitting
Note) When A and B ports are inch size, the
One-touch fitting will be changed to ø5/16".
37
t SI Unit (Output polarity)
Nil
N
(Without SI Unit)
Negative common
y Option
Nil
B Note 1)
D
D0
D Note 2)
K Note 3)
N
R Note 4)
S
None
With back pressure check valve (All stations)
With DIN bracket, DIN rail with standard length
With DIN bracket, without DIN rail
With DIN bracket, DIN rail for stations
Special wiring specification (Except double wiring)
With name plate
External pilot
Built-in silencer
∗ When multiple symbols are specified, indicate
them alphabetically. Example) “-BKN”
Note 1) When a back pressure check valve is
used only for specified station, specify
the back pressure check valve part
number, and specify the station number
to which the valve is mounted, on the
manifold specification sheet.
Note 2) : Specify a longer rail than the length
of valve stations.
Example) “-D08”
In this case, the valves will be mounted
on the DIN rail for 8 stations, regardless
of the number of manifold stations.
Note 3) When single wiring and double wiring
are mixed, specify wiring type of each
station on the manifold specification
sheet.
Note 4) For external pilot option “-R”, indicate
the external pilot specification “R” for
the applicable valves as well.
Gateway Decentralized System 2
5 Port Solenoid Valve
Series S0700
How to Order Valves
A
A Note)
B
C
B Function
A Type of actuation
1
2
5
C Rated voltage
Nil
R Note)
2-position single
2-position double
4-position dual 3-port (N.C. + N.C.)
[Exhaust center]
Gateway Decentralized System 2
S07 1 0
5
Internal pilot
External pilot
24 VDC
Note) For external pilot, select “1” 2-position
single or “2” 2-position double.
4-position dual 3-port (N.O. + N.O.)
B Note) [Pressure center]
C Note) 4-position dual 3-port (N.C. + N.O.)
Note) For 4-position dual 3-port, select “Nil”
internal pilot.
SY
VQC
S0700
SV
How to Order Manifold Assembly
Example
2-position double
4-position dual 3-port
D
si
de
1
2
3
St
at
io
ns
U
si
de
Manifold base
SS0750-04C4SDA3 ···1 set (Manifold base part number)
∗ S0720-5 ··················· 2 sets (2-position double part number)
∗ S07A0-5···················2 sets (4-position dual 3-port number)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold base part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on the manifold specification sheet.
38
Series S0700
Dimensions
L4
L3
L2
5.25
L1
38.8
(12)
4.4
(n – 1) x 8.5
1.5
(76.7)
Light
12.8
8.5
S0720-5
S07A0-5
S07A0-5
12
12
72
S0720-5
12
62
S0720-5
12
39
S0710-5
12
y4
5
S0710-5
101.4
14
14
14
14
14
14
14
14
S0710-5
(35)
(5.5)
Manual override
SI Unit
4 x M4 Mounting hole
D side
Station
1
2
3
4
5
6
7
n
8
U side
M12
B 2
B 2
B 2
B 2
B 2
B 2
B
4 A
4 A
4 A
4 A
4 A
4 A
4 A
4
6.5
(7.5)
M12
8.5
One-touch fitting
[1(P), 3(R) port]
Applicable tube O.D.: ø6, ø1/4"
ø8, ø5/16"
Dimensions
n
L
L1
L2
L3
L4
39.5
n
L
L1
L2
L3
L4
39
1
33.6
B 2
A
17.5
2
9.6
25.6
46.2
76.7
IN
(12)
67.2
OUT
17.2
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø2
ø3.2, ø1/8"
ø4, ø5/32"
Formula: L1 = 8.5n + 31, L2 = 8.5n + 74 n: Stations (Maximum 24 stations)
2
48
3
4
5
6
7
8
9
10
11
12
13
14
15
16
56.5
65
73.5
82
90.5
99
107.5
116
124.5
133
141.5
150
158.5
167
99.5
82.5
91
108
116.5
125
133.5
142
150.5
159
167.5
176
184.5
193
201.5
210
112.5
112.5
125
137.5
137.5
150
162.5
162.5
175
187.5
187.5
200
212.5
212.5
225
237.5
123
123
135.5
148
148
160.5
173
173
185.5
198
198
210.5
223
223
235.5
248
17
18
19
20
21
22
23
24
175.5
184
192.5
201
209.5
218
226.5
235
218.5
227
235.5
244
252.5
261
269.5
278
250
250
262.5
275
275
287.5
300
300
260.5
260.5
273
285.5
285.5
298
310.5
310.5
Gateway Decentralized System 2
5 Port Solenoid Valve
®
For detailed specifications, Common Precautions and Specific Product Precautions, refer to the WEB catalog or the SV series catalog (CAT. ES11-81).
How to Order Manifold
SS5V 1 W 10 S 1 A3N D 05 U
e r t
r P, E port entry
SV1000
SV2000
SV3000
U
D
B
u
u Mounting
U side (2 to 10 stations)
D side (2 to 10 stations)
Both sides (2 to 20 stations)
Nil
D
D0
D3 Note)
Direct mounting
With DIN bracket, DIN rail with standard length
With DIN bracket, without DIN rail
With DIN bracket, DIN rail for 3 stations
w SI Unit (Number of outputs, Output polarity,
Max. number of valve stations)
A3N
Without SI Unit
32 outputs Note 1, 3), Negative common,
1 to 16 stations (20 stations Note 2))
Internal pilot
Internal pilot, Built-in silencer Note)
External pilot
External pilot, Built-in silencer Note)
Note) When the built-in silencer type is used,
keep the exhaust port from coming in
direct contact with water or other liquids.
SV
Note 1) 16 outputs can be set by switching the
built-in setting switch.
Note 2) ( ): Maximum number of stations for
mixed single and double wiring.
Note 3) When using the SI Unit with 32 outputs,
use the GW Unit compatible with the
EX500 Gateway Decentralized System
2 (128 points).
Nil
S
R
RS
y A, B port size
Metric size
e Valve stations
…
…
Stations
02 2 stations
…
…
16 16 stations
02 2 stations
20 20 stations
Note
Double wiring Note 1)
Mixed wiring, Specified layout Note 2)
(Available up to 32 solenoids)
Note 1) Double wiring: single, double, 3-position
and 4-position valves can be used on all
manifold stations.
Use of a single solenoid will result in an
unused control signal. If this is not
desired, order with a specified layout.
Note 2) Specified layout: Indicate the wiring
specifications on the manifold specification sheet. (Note that double,
3-position and 4-position valves cannot
be used where single wiring has been
specified.)
C3
C4
C6
C4
C6
C8
C6
C8
C10
M Note)
A, B port
ø3.2 One-touch fitting
ø4 One-touch fitting
ø6 One-touch fitting
ø4 One-touch fitting
ø6 One-touch fitting
ø8 One-touch fitting
ø6 One-touch fitting
ø8 One-touch fitting
ø10 One-touch fitting
A, B port mixed
P, E port
ø8
One-touch
fitting
Applicable series
SV1000
ø10
One-touch
fitting
SV2000
ø12
One-touch
fitting
SV3000
Inch size
N1
N3
N7
N3
N7
N9
N7
N9
N11
M Note)
A, B port
ø1/8" One-touch fitting
ø5/32" One-touch fitting
ø1/4" One-touch fitting
ø5/32" One-touch fitting
ø1/4" One-touch fitting
ø5/16" One-touch fitting
ø1/4" One-touch fitting
ø5/16" One-touch fitting
ø3/8" One-touch fitting
A, B port mixed
P, E port
ø5/16"
One-touch
fitting
S0700
0
t SUP/EXH block assembly
VQC
D20 Note) With DIN bracket, DIN rail for 20 stations
Note) Specify a longer rail than the length of
valve stations.
∗ If the DIN rail must be mounted without an SI
Unit, select “D0” and order the DIN rail
separately. Refer to L3 of the dimensions for
the DIN rail length. For the DIN rail part
number, refer to the WEB catalog or the SV
series catalog (CAT. ES11-81).
SY
1
2
3
y
…
q Series
w
…
q
Gateway Decentralized System 2
Series SV1000/2000/3000
Applicable series
SV1000
ø3/8"
One-touch
fitting
SV2000
ø3/8"
One-touch
fitting
SV3000
Note) Indicate the sizes on the manifold specification sheet.
∗ The X and PE port size of external pilot type [R, RS] are ø4 (mm) or
ø5/32” (inch) for the SV1000/2000 series, and ø6 (mm) or ø1/4” (inch)
for the SV3000 series.
40
Series SV1000/2000/3000
How to Order Valves
SV 1 1 0 0
5 F
A B
1
2
3
Nil
K
SV1000
SV2000
SV3000
B Type of actuation
A Note)
B Note)
C Note)
E
F G
D Back pressure check valve
A Series
1
2
3
4
5
C D
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual 3-port valve (N.C./N.C.)
4-position dual 3-port valve (N.O./N.O.)
4-position dual 3-port valve (N.C./N.O.)
Note) Select the SV1000 or SV2000 series for
the 4-position dual 3-port valve.
∗ Select the internal pilot type for the 4-position
dual 3-port valve.
I
G Manual override
Nil
None
Built-in
Non-locking push
∗ Built-in back pressure check valve type is
applicable to the SV1000 series only.
∗ The product with a back pressure check valve
is not available for 3-position valves.
∗ Refer to the WEB catalog for built-in back
pressure check valve type.
D
E Rated voltage
5
Push-turn locking
(slotted)
24 VDC
F Light/surge voltage suppressor
U
R
With light/surge voltage suppressor
Without light, with surge voltage suppressor
C Pilot type
Nil
R
H
H Manifold block
Internal pilot
External pilot
If stations are to be added, order the product
with manifold block.
(For details, refer to the WEB catalog.)
I Made to Order
Nil
X90
—
Main valve fluororubber specification
(For details, refer to the WEB catalog.)
How to Order Manifold Assembly
Example
2-position double
2-position single
Manifold base
Us
ide
t
ta
S
SS5V1-W10S1A3ND-04B-C6······1 set (Manifold base part number)
∗ SV1100-5FU······························2 sets (2-position single part number)
∗ SV1200-5FU······························2 sets (2-position double part number)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
s
n
io
3
41
2
1
Ds
ide
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold base part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on the manifold specification sheet.
Gateway Decentralized System 2
5 Port Solenoid Valve
Series SV1000
Series SV1000
Tie-rod Base
Dimensions
4 x ø5.3
(For mounting)
B
A
A
A
A
B
90.9
4.6
40.4
92.6
B
B
(35)
A
B
101.4
A
A
B
83
(5.5)
29.6
1.9
Light/surge voltage suppressor
B
Gateway Decentralized System 2
(L2)
(DIN rail mounting hole pitch: 12.5)
(5)
Manual override
4(A) port side: Orange
2(B) port side: Green
U side
(L1)
(39.6)
D side
(8)
Silencer
SY
(4.9)
(C6: 3.2)
(N7: 7)
3-NC
3-NC
SI Unit
L5
33.7
(L4)
L3
(42.3)
(Station n)
(8.4)
One-touch fitting
[PE: Pilot EXH port]
Applicable tube O.D. C4: ø4 (SMC)
N3: ø5/32" (SMC)
S0700
One-touch fitting
[X: External pilot port] Note 1)
Applicable tube O.D. C4: ø4 (SMC)
N3: ø5/32" (SMC)
M12
VQC
(Station 1)
SV
A4
A4
A4
3/5
(11.8)
E
A
(7.5)
A4
10
4
1
58.7
3/5
P
45.5
E
2 B2 B2 B2 B2 B
24.6
1
9.2
P
22.2
IN
25.6
(43)
46.2
44.7
M12
8.6
(56.5)
(External pilot spec.)
76.7
67.2
OUT
One-touch fitting
[1(P), 3/5(E) port] Note 2)
Applicable tube O.D. C8: ø8 (SMC)
N9: ø5/16" (SMC)
(Pitch)
P = 10.5
46.5
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D. C3: ø3.2 (SMC)
C4: ø4 (SMC)
C6: ø6 (SMC)
N1: ø1/8" (SMC)
N3: ø5/32" (SMC)
N7: ø1/4" (SMC)
13.5
Note 1) External pilot port positions and silencer discharge port positions are the same as P, E port outlet positions.
Note 2) When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged.
L: DIN Rail Overall Length
n
L
L1
L2
L3
L4
L5
2
3
4
135.5 148
148
125
5
n: Stations
6
160.5 173
137.5 137.5 150
7
8
185.5 198
162.5 175
9
10
11
210.5 210.5 223
187.5 200
200
12
13
235.5 248
212.5 225
14
15
16
260.5 273
273
237.5 250
17
18
285.5 298
262.5 262.5 275
19
20
310.5 323
287.5 300
312.5
102.2 112.7 123.2 133.7 144.2 154.7 165.2 175.7 186.2 196.7 207.2 217.7 228.2 238.7 249.2 259.7 270.2 280.7 291.2
16.5
17.5
12.5
13.5
63
73.5
84
94.5 105
14.5
15.5
16.5
115.5 126
17.5
12
136.5 147
13
14
157.5 168
15
16
178.5 189
17
12
199.5 210
13
14
220.5 231
15
16
241.5 252
42
Series SV2000
Series SV2000
Tie-rod Base
Dimensions
D side
(L2)
(DIN rail mounting hole pitch: 12.5)
B
115.5
B
97.5
A
A
A
A
B
(53.4)
29.6
(5.5)
B
90.9
A
B
(35)
A
B
101.4
A
B
41.8
5.4
Light/surge voltage suppressor
109.4
(5)
5.9
Manual override
4(A) port side: Orange
2(B) port side: Green
U side
(L1)
(8)
(5.3)
Silencer
(4.9)
3-NC
3-NC
SI Unit
4 x ø5.3
(For mounting)
L5
34.2
(L4)
L3
(Station 1)
One-touch fitting
[X: External pilot port] Note 1)
Applicable tube O.D. C4: ø4 (SMC)
N3: ø5/32" (SMC)
(43.9)
(9.5)
(Station n)
One-touch fitting
[PE: Pilot EXH port]
Applicable tube O.D. C4: ø4 (SMC)
N3: ø5/32" (SMC)
2
A
4A
4A
4A
4A
4
1
E
3/5
12
3/5
P
(11.8)
2B
(7.5)
2B
63.5
2B
52.5
2B
30.6
E
B
11.9
1
25.2
P
IN
25.6
46.2
M12
9.2
OUT
(49.9)
(63.5)
(External pilot spec.)
76.7
67.2
M12
One-touch fitting
[1(P), 3/5(E) port] Note 2)
Applicable tube O.D. C10: ø10 (SMC)
N11: ø3/8" (SMC)
(Pitch)
P = 16
48.7
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D. C4: ø4 (SMC)
C6: ø6 (SMC)
C8: ø8 (SMC)
N3: ø5/32" (SMC)
N7: ø1/4" (SMC)
N9: ø5/16" (SMC)
17.5
Note 1) External pilot port positions and silencer discharge port positions are the same as P, E port outlet positions.
Note 2) When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged.
L: DIN Rail Overall Length
n
L
L1
L2
L3
L4
L5
43
2
148
3
4
5
160.5 185.5 198
137.5 150
175
n: Stations
6
7
8
210.5 235.5 248
187.5 200
225
9
10
11
260.5 273
298
237.5 250
12
13
310.5 323
262.5 287.5 300
14
15
16
335.5 360.5 373
312.5 325
350
17
18
19
385.5 410.5 423
362.5 375
400
20
435.5
412.5 425
120.2 136.2 152.2 168.2 184.2 200.2 216.2 232.2 248.2 264.2 280.2 296.2 312.2 328.2 344.2 360.2 376.2 392.2 408.2
14
12
80
96
16.5
112
15
13
128
144
17.5
160
16
14
176
192
12.5
208
17
15
224
240
13.5
256
11.5
272
16
288
14.5
304
12.5
320
17
336
15.5
352
13.5
368
Gateway Decentralized System 2
5 Port Solenoid Valve
Series SV3000
Series SV3000
Tie-rod Base
Dimensions
D side
U side
Gateway Decentralized System 2
(L1)
(DIN rail mounting hole pitch: 12.5)
(L2)
(5)
Light/surge voltage suppressor
(8)
128.8
B
104.1
B
(46.9)
B
83.8
A
A
A
A
B
43.9
29.6
B
(35)
A
B
90.9
A
101.4
(5.5)
5.4
5
Manual override
4(A) port side: Orange
2(B) port side: Green
4 x ø5.3
(For mounting)
SY
SI Unit
(5.3)
VQC
(5.1)
Silencer
L5
36.2
(L4)
L3
(47.7)
(Station n)
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D. C6 : ø6 (SMC)
C8 : ø8 (SMC)
C10: ø10 (SMC)
N7 : ø1/4" (SMC)
N9 : ø5/16" (SMC)
N11: ø3/8" (SMC)
(11)
One-touch fitting
[PE: Pilot EXH port]
Applicable tube O.D. C6: ø6 (SMC)
N7: ø1/4" (SMC)
(76.8)
(External pilot spec.)
M12
2
P
1
A
4 A
4 A
4 A
4 A
4 E
3/5
11.6
IN
12
(14.7)
2B
(10)
2B
82.7
2B
63.8
3/5
2B
37.6
E
B
13.5
1
36.1
P
25.6
M12
46.2
(60.3)
76.7
67.2
OUT
53.2
21.2
(Pitch)
P = 20.5
One-touch fitting
[1(P), 3/5(E) port] Note 2)
Applicable tube O.D. C12: ø12 (SMC)
N11: ø3/8" (SMC)
Note 1) External pilot port positions and silencer discharge port positions are the same as P, E port outlet positions.
Note 2) When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged.
L: DIN Rail Overall Length
n
L
L1
L2
L3
L4
L5
2
173
3
7
8
185.5 210.5 235.5 248
273
298
200
5
n: Stations
6
162.5 175
4
225
9
11
12
13
310.5 335.5 348
373
398
237.5 262.5 287.5 300
10
325
14
17
18
19
410.5 435.5 460.5 473
498
523
337.5 362.5 387.5 400
15
425
16
450
20
535.5
462.5 487.5 512.5 525
139.7 160.2 180.7 201.2 221.7 242.2 262.7 283.2 303.7 324.2 344.7 365.2 385.7 406.2 426.7 447.2 467.7 488.2 508.7
16.5
97
12.5
15
117.5 138
17
13
158.5 179
15.5
17.5
199.5 220
13.5
16
240.5 261
12
14
281.5 302
16.5
12.5
322.5 343
14.5
17
363.5 384
13
15
404.5 425
17.5
13.5
445.5 466
44
SV
One-touch fitting
[X: External pilot port] Note 1)
Applicable tube O.D. C6: ø6 (SMC)
N7: ø1/4" (SMC)
S0700
(Station 1)
Series EX500
Precautions on Mixed Usage of Gateway
Decentralized System 2 (128 Points) and
Gateway Decentralized System (64 Points)
GW Unit
Gateway Decentralized System 2
(128 points)
• EX500-S103
• EX500-DX
SI Unit
Input Unit
Gateway Decentralized System
(64 points)
• EX500-GEN2
• EX500-GPN2
• EX500-GDN1
• EX500-GPR1A
Usable
Usable
Same functions of Gateway
Decentralized System (64 points)
Usable
Same functions of Gateway
Decentralized System (64 points)
Usable
Gateway Decentralized System
(64 points)
• EX500-S001
• EX500-Q001/002
• EX500-Q101/102
• EEX500-IB1-
(EX500-IB1)
45
Gateway Decentralized System 2
(128 points)
Series EX500
Gateway Decentralized System (64 Points)
Valve manifold and Input Unit can be connected around the GW (Gateway) Unit.
Compatible with other protocols by replacing the GW Unit.
Number of inputs/outputs = 64 points/64 points. The number of outputs (solenoids) per branch is 16 points.
Number of valve manifold connections = Max. 4 Units, Number of Input Unit connections = Max.
4 Units, Cable length = Max. 10 m
No need to set the address for the valve manifold and Input Unit.
Gateway Decentralized System
SY
SY3000/5000/7000
………………………………………………………
Page 57
VQC
VQC1000/2000/4000/5000 ………………………………………… Page 65
S0700 ……………………………………………………………………………… Page 77
……………………………………………
S0700
SV1000/2000/3000/4000
Page 80
SV
46
Series EX500
Gateway Decentralized System (64 Points)
GW Unit
®
RoHS
How to Order
EX500 G DN1
Communication protocol
Dimensions/Parts Description
DeviceNet™
PROFIBUS DP
Release 2.0
DP-V0
Terminating
resistor
Not provided
Built into the Unit
For control
11 to 25 VDC
(Supplied by DeviceNet™
circuit, 50 mA or less)
24 VDC ±10%
3.0 A or less (Max. 0.75 A per branch x 4 branches)
Number of
branch ports
4 ports
Number of inputs
and outputs
16 inputs/16 outputs per branch
Branch cable
length
5 m or less between connected devices
(10 m or less per branch)
Enclosure
IP65
Standards
Weight
Enclosed parts
12
COM B
COM C
COM D
Branch port
M12, 8 pins, A-coded, socket
160
136
Operating: 5 to 45°C, Stored: –25 to 70°C
(No freezing and condensation)
Operating, Stored: 35 to 85%RH
(No condensation)
CE marking, UL (CSA), RoHS compliant
470 g
Seal cap
(for M12 connector)
4 pcs.
Seal cap
(for M12 connector)
5 pcs.
EX500-GPR1A (PROFIBUS DP)
Cover screw
4 x M3
Communication connector
(M12, 5 pins,
B-coded, plug)
Cover (Setting switch)
Mounting hole
4 x M5
Ground terminal (FE)
M3
148
Indicator LED
Communication connector
(M12, 5 pins,
B-coded, socket)
GATEWAY UNIT
EX500 SERIES
IN
RUN
SOL
BUS
BF
DIA
OUT
Power supply connector
(M12, 5 pins,
A-coded, plug)
24VDC
COM A
COM B
COM C
COM D
Branch port
M12, 8 pins, A-coded, socket
160
136
49.9
Note 1) Note that the version is subject to change.
Note 2) Each file can be downloaded from SMC website, http://www.smcworld.com
47
COM A
88
For valve
Operating
humidity range
24VDC
46
24 VDC +10%, –5%
3.0 A or less
(Max. 0.7 A per branch x 4 branches + GW Unit
internal current consumption: 0.2 A or less)
Operating
Environment temperature range
Power supply
connector
(M12, 5 pins,
A-coded, socket)
24 VDC ±10%
For input
and
Current
consumption control
Branch
port
EX500 SERIES
MS
NS
SOL
68
For valve
GATEWAY UNIT
BUS
12
For input device
Indicator LED
GSD file
64 inputs/64 outputs
(8 bytes/8 bytes)
Mounting hole
4 x M5
Ground terminal (FE)
M3
148
46
Power
supply
voltage
Communication
connector
(M12, 5 pins,
A-coded, plug)
10
Number of
inputs/outputs
(I/O occupation area)
EDS file
Cover (Setting switch)
Cover screw
4 x M3
10
Configuration
file Note 2)
9.6 k/19.2 k/45.45 k/
93.75 k/187.5 k/500 k/
1.5 M/3 M/6 M/12 Mbps
EX500-GDN1 (DeviceNet™)
88
EX500-GPR1A
68
EX500-GDN1
Communication
125 k/250 k/500 kbps
speed
Communication
PROFIBUS DP
(Input/Output = 64 points/64 points)
PE
Version Note 1)
PR1A
48.8
Model
Protocol
DeviceNet™
(Input/Output = 64 points/64 points)
PE
Specifications
DN1
Series EX500
Gateway Decentralized System (64 Points)
SI Unit
®
Output Unit for valve manifold connection
How to Order
For SV1000/2000/3000/4000
EX500
RoHS
S001
Applicable valve:
Series SV
Specifications
EX500-S001
Model
Number of outputs
Output
16 outputs
Output type
Sink/NPN (Positive common)
Supply current
Max. 0.65 A
Rated voltage
24 V
Internal current consumption
100 mA or less
Enclosure
Environment
IP67
Operating temperature range
Operating: 5 to 45°C, Stored: –25 to 70°C (No freezing and condensation)
Operating humidity range
Operating, Stored: 35 to 85%RH (No condensation)
Standards
CE marking, UL (CSA), RoHS compliant
Weight
115 g
Gateway Decentralized System
Enclosed parts
Seal cap (for M12 connector socket) 1 pc.
Dimensions/Parts Description
EX500-S001
Position indicator LED
79.4
Branch connector (C1)
(M12, 8 pins, A-coded, socket)
Branch connector (C2)
(M12, 8 pins, A-coded, plug)
15.5
39
VQC
54.5
SY
28.6
68.5
S0700
SV
48
Series EX500
How to Order
For SY3000/5000/7000,
VQC1000/2000/4000/5000,
S0700
EX500 Q 0 0 1
Applicable valve:
Series SY/VQC/S0700
E
X
se 50
rie 0
s
Output specification
SI Unit type
0 NPN (Positive common)
1 PNP (Negative common)
1
2
For without EX9 output block
For EX9 output block mounting
Specifications
EX500-Q001
Model
Number of outputs
EX500-Q002
Rated voltage
24 VDC
Supply current
Max. 0.75 A
Internal current consumption
100 mA or less
Enclosure
Environment
EX500-Q102
16 outputs
Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common)
Output type
Output
EX500-Q101
IP67
Operating temperature range
Operating: 5 to 45°C, Stored: –25 to 70°C (No freezing and condensation)
Operating humidity range
Operating, Stored: 35 to 85%RH (No condensation)
Standards
CE marking, RoHS compliant
Weight
105 g
Enclosed parts
Seal cap (for M12 connector socket) 1 pc.
Dimensions/Parts Description
EX500-Q01
EX500-Q02
Position indicator LED
series
EX500
COM
PWR
SI UNIT
COM
PWR
Position indicator LED
2 x M4 Mounting hole
66
28
64.4
Branch connector (0)
(M12, 8 pins, A-coded, socket)
80.3
36
64.4
Branch connector (1)
Branch connector (1)
(M12, 8 pins, A-coded, plug)
0
22.2
43.2
85.7
49
(M12, 8 pins, A-coded, plug)
1
60
1
22.2
60
0
44
43.2
Branch connector (0)
(M12, 8 pins, A-coded, socket)
80.3
Series EX500
Gateway Decentralized System (64 Points)
Input Manifold
®
RoHS
How to Order Input Manifold
EEX500 IB1
How to Order Input Block
E 8
EX500 IE 1
Block type
1 1 station
…
E M8 connector
T M12 connector
M M8, M12 mixed
1
2
3
4
5
6
Stations
…
Connector type
8 8 stations
M8 connector, 2 inputs, PNP specification
M8 connector, 2 inputs, NPN specification
M12 connector, 2 inputs, PNP specification
M12 connector, 2 inputs, NPN specification
M8 connector, 8 points integrated type, PNP specification
M8 connector, 8 points integrated type, NPN specification
Input Manifold
Input Unit
Input block (M8 connector)
Input block (M12 connector)
End block
DIN rail
Input block (M8 connector) 8 points integrated type
Gateway Decentralized System
How to Order Input Manifold [Ordering Example]
When ordering an Input Unit manifold, enter the Input manifold part number + Input block part number .
Please mention the connected input block part numbers in order from the Input Unit side under the input manifold part number.
When an input block layout becomes complicated, indicate in the Input Unit manifold specification sheet.
∗ The Input Unit , End block and DIN rail are included in the input manifold.
Example 1) M8 Input block only
Example 2) M12 Input block only
EEX500-IB1-T4 ········· 1 set
∗ EX500-IE4 ·············· 4 sets
VQC
Example 3) M8, M12 mixed
EEX500-IB1-M6········· 1 set
∗ EX500-IE1··············· 4 sets
∗ EX500-IE3··············· 2 sets
S0700
EEX500-IB1-E8 ········· 1 set
∗ EX500-IE1 ·············· 8 sets
SV
EEX500-IB1-E6 ········· 1 set
∗ EX500-IE5 ·············· 1 set Note)
∗ EX500-IE1 ·············· 2 sets
SY
EEX500-IB1-E8 ········· 1 set
∗ EX500-IE5 ·············· 2 sets Note)
Note) 8-point integrated type input block (EX500-IE5/6) is equivalent
to 4 stations of 2-point input block (EX500-IE1/2).
50
Series EX500
Specifications (Input Unit)
EX500-IB1
Model
Number of inputs
Input
16 inputs
Connection block
EX500-IE (Mixed combination is possible.)
Connection block
stations
2-input, input block: Max. 8 stations
8-input, input block: Max. 2 stations
Internal current consumption
100 mA or less
Enclosure
Environment
IP65
Operating temperature range
Operating: 5 to 45°C, Stored: –25 to 70°C (No freezing and condensation)
Operating humidity range
Operating, Stored: 35 to 85%RH (No condensation)
Standards
CE marking, UL (CSA), RoHS
Weight
100 g (Input Unit + End block)
Specifications (Input Block)
Model
Connector type
Input type
Input
EX500-IE1
EX500-IE2
PNP
NPN
Number of inputs
Enclosed parts
51
EX500-IE5
PNP
EX500-IE6
M8 (3 pins)
NPN
PNP
2 inputs
NPN
8 inputs
Input device supply voltage
24 VDC
Input device supply current
Max. 480 mA/Input Unit manifold
Rated input current
Approx. 5 mA
IP65
Operating temperature range
Operating: 5 to 45°C, Stored: −25 to 70°C (No freezing and condensation)
Operating humidity range
Operating, Stored: 35 to 85%RH (No condensation)
Standards
Weight
EX500-IE4
M12 (4 pins)
Enclosure
Environment
EX500-IE3
M8 (3 pins)
CE marking, UL (CSA), RoHS compliant
20 g
40 g
55 g
Seal cap (for M8 connector) 2 pcs.
Seal cap (for M12 connector) 2 pcs.
Seal cap (for M8 connector) 8 pcs.
Gateway Decentralized System (64 Points)
Input Manifold
Series EX500
Dimensions/Parts Description
Input block (M8) only
Sensor connector
(M8, 3 pins, socket)
47
(Pitch)
P = 12
31
8
DIN rail
21
49
35
5.5
Branch connector
(M12, 8 pins, A-coded, plug)
(L4)
L3
L2
Position indicator LED
5
(Rail mounting pitch: 12.5)
39.7
32.2
(7.5)
44.2
L1
[mm]
1
Stations
Rail length L1
2
3
98
110.5 123
100
Mounting pitch L2
87.5
Manifold length L3
74
86
98
L4
12
12
12.5
4
5
135.5 148
112.5 125
110
12.5
6
7
160.5 173
8
185.5
137.5 150
162.5 175
122
134
146
13
13
13.5
158
13.5
Gateway Decentralized System
Input block (M12) only
Branch connector
(M12, 8 pins, A-coded, plug)
47
(Pitch)
P = 20
Sensor connector
(M12, 4 pins, socket)
31
DIN rail
25
(L4)
L3
L2
Position indicator LED
60
35
31
5.5
8
5
SY
(Rail mounting pitch: 12.5)
32.2
46.9
S0700
(7.5)
VQC
44.2
L1
[mm]
Stations
2
3
4
110.5 123
148
173
5
6
7
8
185.5 210.5 223
248
Mounting pitch L2
100
112.5 137.5 162.5 175
200
212.5 237.5
Manifold length L3
82
102
162
182
202
L4
12
12
13
13
122
12.5
142
12.5
13.5
SV
Rail length L1
1
222
13.5
52
Series EX500
How to Add Input Block Stations
How to add input block stations
1. Loosen the round head combination screws (2 places) that hold the end block.
2. Separate the blocks at the locations where stations are to be added.
3. Attach the additional blocks to the DIN rail, and connect the blocks so that they fit together securely.
4. While holding the blocks together so that there are no gaps between them, secure them to the DIN rail by tightening the round head combination screws.
Note: Be sure to tighten the round head combination screw with the prescribed tightening torque. (0.6 N·m)
@
Round head
combination screw
.
:
;
Round head
combination screw
=
B
Parts List
No.
Part number
For standard
Description
Note
q
Input Unit
EX500-IB1
w
Input block (M8 connector)
EX500-IE
e
Input block (M12 connector)
EX500-IE
PNP Specification…: 1, NPN Specification…: 2
PNP Specification…: 3, NPN Specification…: 4
r
Input block (M8 connector) 8 points integrated type
EX500-IE
PNP Specification…: 5, NPN Specification…: 6
t
End block
EX500-EB1
y
DIN rail
: Number based on L dimension (Refer to the table below.)
VZ1000-11-1-
DIN Rail L Dimensions [mm]
Stations
1
0
2
1
1
1
2
2
2
3
3
4
4
5
5
6
6
7
3
4
5
6
7
8
9
4
6
7
8
9
10
5
7
8
9
10
6
9
10
11
7
10
11
8
12
M12 input block (n)
0
Connector type
For T (n = 1 to 8)
53
M8 input block (m)
3
4
5
2
3
4
0
6
5
7
6
7
8
8
Connector type
For M (m + n = 2 to 8)
8
Connector type
For E (m = 1 to 8)
7
L dimensions
No.
L
L
No.
dimension
dimension
0
98
7
185.5
1
110.5
8
198
2
123
9
210.5
3
135.5
10
223
4
148
11
235.5
5
160.5
12
248
6
173
Series EX500
Gateway Decentralized System (64 Points)
Accessories
EX500 AP 050
w Branch Cable
S
Cable length (L)
010
050
EX500 AC 030
Connector specification
S
A
1000 [mm]
5000 [mm]
Cable length (L)
Straight
Angle
003
005
010
030
050
ø6
M12
30
ø14.9
40.7
Connector specification
300 [mm]
500 [mm]
1000 [mm]
3000 [mm]
5000 [mm]
Socket side: Straight
SSPS Plug side: Straight
Socket side: Angle
SAPA Plug side: Angle
L
5
44.7
40.7
50
ø6
L
SSPS
ø14.9
q Power Supply Cable
M12
ø14.9
M12
M12
M12
30
25.3
L
5
25.3
50
2
A-coded
Brown: 0 V (for solenoid valve)
White: 24 VDC (for solenoid valve)
Blue: 0 V (for control and input)
Black: 24 VDC (for control and input)
Gray: Ground
1
2
4
3
Socket pin
arrangement
3
4
5
Connections
8
1
7
3
6
A-coded
8
2
4
5
Socket pin
arrangement
2
1
3
7
4
6
5
Plug pin
arrangement
Gateway Decentralized System
1
25.3
L
A-coded
5
32.3
ø6
28.3
28.3
ø6
M12
SY
VQC
S0700
SV
54
Series EX500
e Communication Cable
For DeviceNetTM
For PROFIBUS DP
EX500 AC 050
PCA-1557688
DN
44.5
5000
50
1000 [mm]
5000 [mm]
M12
SPEEDCON
ø7
M12
ø7.8
010
050
ø14.8
Cable length (L)
B-coded
ø14.9
5
4
40.7
4
4
4
: DRAIN
Red: V+
Black: V–
White: CAN H
Blue: CAN L
1
2
3
5
3
PCA-1557691
Connections
47.3
PCA-1557633
44.5
5000
5000
50
M12
SPEEDCON
50
ø14.8
B-coded
5
ø6.7
M12
SPEEDCON
1
5
2
1
2
4
4
Red: V+
3
: DRAIN
Black: V–
White: CAN H
Blue: CAN L
5
3
Socket pin
arrangement
1
4
A-coded
1
2
2
4
55
Shield line is connected to the knurl.
Connections
ø14.8
Socket pin
arrangement
5
ø7.8
2
:—
Green: A Line
:—
Red: B Line
:—
3
3
Socket pin
arrangement
A-coded
1
1
2
50
L
5
2
1
Connections
3
5
:—
Green: A Line
:—
Red: B Line
:—
3
Plug pin
arrangement
Shield line is connected to the knurl.
Connections
Gateway Decentralized System (64 Points)
Accessories
Series EX500
r Terminal Plug
y Seal Cap (10 pcs.)
Use this where an input unit manifold is not being used. (If a terminal
plug is not used, the GW unit’s COM LED will not light up.)
Use with new connector. By using these waterproof caps, the new
connector maintains IP65/67 enclosure.
EX500 AC000 S
EX9-AWES
M12
A-coded
2
1
3
7
4
ø16
8
EX9-AWTS
For M8 connector socket For M12 connector socket
6
5
Plug pin
arrangement
44.7
t Seal Cap (1 pc.)
Use with new connector (plug). By using these waterproof caps, the
connector maintains IP65/67 enclosure.
EX500 AWTP
ø14.9
9.4
Refer to page 14 for details about output block and power block.
Gateway Decentralized System
SY
VQC
S0700
SV
56
Gateway Decentralized System
Type 10
Side Ported
5 Port Solenoid Valve
Type 11
Bottom Ported
RoHS
Series SY3000/5000/7000
For detailed specifications, Common Precautions and Specific Product Precautions, refer to the WEB catalog or the SY series catalog (CAT. ES11-103).
How to Order Manifold
SS5Y 3
10 S A2
q
q Series
r
e SI Unit (Number of outputs, Output polarity,
t y
∗ For mixed mounting, refer to the WEB catalog
or the SY series catalog (CAT. ES11-103).
A2N
Note 1) Ensure a match with the common specification of the valve to be used.
Note 2) ( ): Maximum number of stations for
single wiring.
w Type
Side ported
Bottom ported Note)
Note) The SY5000 manifold base is used for
the bottom ported of the SY3000. When
ordering, refer to the WEB catalog or the
SY series catalog (CAT. ES11-103).
∗ When mixing top ported configurations, select
from page 61.
In this case, use caution as there is also
output on the A and B port on base side.
Specify on a manifold specification sheet if
plugs are required on the A and B port on
base side.
How to Order Manifold Assembly
Example
Stations
Note
…
Double wiring Note 1)
08 8 stations
02 2 stations
…
A2
i
02 2 stations
…
16 outputs, Positive common Note 1),
1 to 8 stations (16 stations) Note 2)
16 outputs, Negative common Note 1),
1 to 8 stations (16 stations) Note 2)
u
r Valve stations
Max. number of valve stations)
SY3000
SY5000
SY7000
10
11
e
C6
…
3
5
7
w
05 U
16 16 stations
Mixed wiring, Specified layout Note 2)
(Available up to 16 solenoids)
Note 1) Double wiring: 2-position single, double,
3-position and 4-position valves can be
used on all manifold stations.
Use of a 2-position single solenoid will
result in an unused control signal.
If this is not desired, order with a
specified layout.
Note 2) Specified layout: Indicate the wiring
specifications on the manifold
specification sheet. (Note that 2-position
double, 3-position and 4-position valves
cannot be used where single wiring has
been specified.)
Note 3) For the product without the SI Unit (S0),
note the maximum number of solenoids
of the SI Unit that will be mounted. If the
layout is specified, indicate it on the
manifold specification sheet.
∗ This also includes the number of blanking
plate assembly.
2-position double
2-position single
3-position closed center
t P, E port entry
U
D
B
U side (2 to 10 stations)
D side (2 to 10 stations)
Both sides (2 to 16 stations)
y SUP/EXH block assembly
D
si
de
1
2
3
S
ta
tio
ns
U
si
de
500
EX ries
se
Manifold base
SS5Y3-10SA2-05D-C6 ······1 set (Manifold base part number)
∗ SY3100-5U1····················3 sets (2-position single part number)
∗ SY3200-5U1····················1 set (2-position double part number)
∗ SY3300-5U1····················1 set (3-position closed center part number)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold base part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on the manifold specification sheet.
57
Nil
S
R
Internal pilot
Internal pilot, Built-in silencer Note 1) 2)
External pilot
Note 1) 3/5(E) port is plugged for the built-in
silencer type.
Note 2) When built-in silencer type is used,
keep the exhaust port from coming in
direct contact with water or other
liquids.
Gateway Decentralized System
5 Port Solenoid Valve
u A, B port size (Metric/One-touch fitting)
—
—
—
—
—
ø4
—
—
ø6
ø8
—
—
—
ø10
—
ø12
—
—
—
Mixed sizes
ø4
—
—
—
ø6
—
—
—
—
—
—
ø12
—
—
—
—
ø4
—
—
—
ø6
—
—
—
ø8
—
—
ø10
—
—
—
—
ø12
—
—
—
—
Mixed sizes
—
—
P, E port Note 3)
ø8
ø10
ø12
ø10
ø12
Downward
Upward
—
—
LM Note 1)
Type 10/Side Ported Type 11/Bottom Ported
SY3000 SY5000 SY7000 SY5000 SY7000
ø1/8"
—
—
—
—
ø5/32"
—
—
ø1/4"
—
ø5/16"
—
—
ø3/8"
—
Mixed sizes
—
—
—
—
—
—
—
—
—
—
—
—
ø5/32"
ø1/4"
ø5/16"
—
ø3/8"
—
—
ø5/32"
—
—
—
—
ø1/4"
—
—
—
ø5/16"
—
—
—
—
ø3/8"
—
—
—
—
—
—
ø1/2"
ø3/8"
ø1/2"
Mixed sizes
P, E port Note 3)
ø5/16" ø3/8"
Note 1) Indicate the sizes on the manifold specification sheet.
Note 2) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly. For details, refer to the
WEB catalog or the SY series catalog (CAT. ES11-103).
Note 3) The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting
direction.
i Mounting and Option
Mounting
Direct
mounting
DIN rail
mounting
SY
Nil
AA
BA
D Note 1)
A Note 1)
B Note 1)
Option
Name plate Station number
—
—
—
—
—
—
S0700
…
VQC
Note 1) Refer to “DIN Rail Option” below.
∗ Select the direct mounting type for Type 11 (Bottom ported).
DIN Rail Option
Nil With DIN bracket, DIN rail with standard length
With DIN bracket, without DIN rail
0
3 Note) With DIN bracket, DIN rail for 3 stations
…
Gateway Decentralized System
ø8
N1
N3
N7
N9
N11
CM Note 1)
LN3
LN7
LN9
LN11
BN3
BN7
BN9
BN11
Straight
—
—
Upward
—
Elbow Note 2)
Straight
ø2
ø3.2
ø10
LM Note 1)
A, B port
SY3000 SY5000 SY7000 SY5000 SY7000
—
Elbow Note 2)
C2
C3
C4
C6
C8
C10
C12
CM Note 1)
L4
L6
L8
L10
L12
B4
B6
B8
B10
B12
A, B port size (Inch/One-touch fitting)
Type 10/Side Ported Type 11/Bottom Ported
Downward
A, B port
Series SY3000/5000/7000
16 Note) With DIN bracket, DIN rail for 16 stations
SV
Note) Specify a longer rail than the length of valve stations.
∗ If the DIN rail must be mounted without an SI Unit, select “D0” and order the
DIN rail separately. Refer to L3 of the dimensions for the DIN rail length.
For the DIN rail part number, refer to the WEB catalog or the SY series
catalog (CAT. ES11-103).
∗ For the fixation of DIN rail mounting type manifold, refer to the WEB catalog
or the SY series catalog (CAT. ES11-103).
Protective class
class # (Mark:
)
58
Series SY3000/5000/7000
How to Order Valves (With mounting screw)
SY 3 1 0 0
q w
5
e r t y u
1
i o !0
!1
Side/Bottom ported
q Series
y Pilot valve option
3
5
7
SY3000
SY5000
SY7000
Nil
B
K Note)
!0 Manual override
Standard (0.7 MPa)
Quick response type (0.7 MPa)
High pressure type (1.0 MPa)
Nil
D
Non-locking
push
Note) Select the metal seal type for high pressure
type.
Push-turn
locking
(slotted)
w Type of actuation
1
2
3
4
5
2-position
3-position
A Note)
4-position dual
B Note) 3-port valve
C Note)
Single
Double
Closed center
Exhaust center
Pressure center
N.C./N.C.
N.O./N.O.
N.C./N.O.
Note) Select the rubber seal type for the 4-position
dual 3-port valve.
e Seal type
0
1
Rubber seal
Metal seal
r Pilot type
Nil
R
Internal pilot
External pilot
u Coil type
Nil
T
Standard
With power saving circuit
(Continuous duty type) Note 1) 2)
Note 1) Be sure to select the power saving circuit
type when the valve is continuously
energized for long periods of time.
Note 2) Be careful of the energizing time when
the power saving circuit is selected. For
details, refer to the WEB catalog or the
SY series catalog (CAT. ES11-103).
i Rated voltage
5
24 VDC
o Light/surge voltage suppressor
and common specification
With light
t Back pressure check valve
Nil
H Note)
None
Built-in
Note) Select the rubber seal type when the
back pressure check valve is built-in.
Manifold installed type is available if the
back pressure check valve is required for
a valve with metal seal. For ordering
example, refer to the WEB catalog or the
SY series catalog (CAT. ES11-103).
However, it is not recommended to use
the built-in valve type and the manifold
installed type at the same time because it
will reduce the flow.
∗ Select “Nil” for 3-position type and the SY7000.
E
R
U
S
Z
NS
NZ
—
—
—
Surge voltage Common
suppressor specification
Non-polar
Positive
common
Negative
common
∗ Only “Z” and “NZ” types are available for with
the power saving circuit. Select a valve from
“R, U, S or Z” when the SI Unit specification is
“A2” (positive common). Select a valve from
“R,U, NS or NZ” when the SI Unit specification
is “A2N” (negative common).
Push-turn
locking
(manual)
F
Slide locking
(manual)
!1 Type of mounting screw
Nil
B
K
Round head combination screw
Hexagon socket head cap screw
Round head combination screw
(Falling-out-prevention type) Note)
H
Hexagon socket head cap screw
(Falling-out-prevention type) Note)
Note) For “K” and “H”, the valve body cover has
a drop prevention construction to stop the
mounting screws from falling out when
the valve is removed for maintenance
etc.
∗ When ordering a valve individually, the
base gasket is not included.
Since the base gasket is attached to the
manifold, please order the base gasket
separately if it is needed for maintenance
service.
For details, refer to the WEB catalog or the
SY series catalog (CAT. ES11-103).
∗ Select “Nil” or “K” for the optional individual
SUP/EXH spacer assembly, interface
regulator or double check spacer assembly
with residual pressure release valve.
Protective class
class # (Mark:
59
)
Gateway Decentralized System
5 Port Solenoid Valve
Type 12
Top Ported
RoHS
Series SY3000/5000/7000
For detailed specifications, Common Precautions and Specific Product Precautions, refer to the WEB catalog or the SY series catalog (CAT. ES11-103).
How to Order Manifold
SS5Y 3 12S A2 05 U
q
q Series
…
Stations
02 2 stations
w SI Unit (Number of outputs, Output polarity,
16 16 stations
r t
common Note 1),
16 outputs, Positive
1 to 8 stations (16 stations) Note 2)
16 outputs, Negative common Note 1),
1 to 8 stations (16 stations) Note 2)
Note 1) Ensure a match with the common specification of the valve to be used.
Note 2) ( ): Maximum number of stations for
single wiring.
y u
r P, E port entry
U Note)
D Note)
B
Note
Double wiring Note 1)
Specified
(Available up to 16 solenoids)
t SUP/EXH block assembly
Nil
S Note 1)
R
Internal pilot
Internal pilot, Built-in silencer Note 2)
External pilot
Note 1) For type “S”, supply/exhaust block
assembly with built-in silencer, choose
“U” or “D” for P, E port entry. 3/5(E)
port is plugged. The silencer exhaust
port is located on the opposite side of
P, E port entry. (Example: When the P,
E port entry is D side, the silencer
exhaust port is U side.)
Note 2) When the built-in silencer type is used,
keep the exhaust port from coming in
direct contact with water or other
liquids.
y P, E port size (One-touch fittings)
Example
2-position double
3-position closed center
2-position single
SY3000
SY5000
SY7000
Nil
ø8
ø10
ø12
N Note)
ø5/16"
ø3/8"
ø1/2"
Note) For “N”, sizes are in inches.
…
de
si
U
ns
tio
ta
S
3
1
de
si
D
Manifold base
SV
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
S0700
SS5Y3-12SA2-05D······1 set (Manifold base part number)
∗ SY3130-5U1-C6········3 sets (2-position single part number)
∗ SY3230-5U1-C6········1 set (2-position double part number)
∗ SY3330-5U1-C6········1 set (3-position closed center part number)
D16 Note) With DIN bracket, DIN rail for 16 stations
Note) Specify a longer rail than the length of valve stations.
∗ If the DIN rail must be mounted without an SI Unit, select
“D0”. Then, refer to L3 of the dimensions for the DIN rail
length and order separately. For the DIN rail part number,
refer to the WEB catalog or the SY series catalog (CAT.
ES11-103).
∗ For the fixation of DIN rail mounting type manifold, refer to
the WEB catalog or the SY series catalog (CAT. ES11-103).
VQC
2
Direct mounting
With DIN bracket, DIN rail with standard length
With DIN bracket, without DIN rail
With DIN bracket, DIN rail for 3 stations
SY
Nil
D
D0
D3 Note)
…
u Mounting
500
EX ries
se
Gateway Decentralized System
How to Order Manifold Assembly
U side (2 to 10 stations)
D side (2 to 10 stations)
Both sides (2 to 16 stations)
Note) For type “S”, supply/exhaust block
assembly with built-in silencer, choose
“U” or “D” for P, E port entry.
layout Note 2)
Note 1) Double wiring: 2-position single, double,
3-position and 4-position valves can be
used on all manifold stations. Use of a
2-position single solenoid will result in
an unused control signal. If this is not
desired, order with a specified layout.
Note 2) Specified layout: Indicate the wiring
specifications on the manifold specification
sheet. (Note that 2-position double, 3-position
and 4-position valves cannot be used where
single wiring has been specified.)
Note 3) For the product without the SI Unit (S0), note
the maximum number of solenoids of the SI Unit
that will be mounted. If the layout is specified,
indicate it on the manifold specification sheet.
∗ This also includes the number of blanking plate assembly.
Max. number of valve stations)
A2N
…
08 8 stations
02 2 stations
…
∗ For mixed mounting, refer to the WEB catalog
or the SY series catalog (CAT. ES11-103).
A2
e
e Valve stations
SY3000
SY5000
SY7000
…
3
5
7
w
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold base part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on the manifold specification sheet.
60
Series SY3000/5000/7000
How to Order Valves (With mounting screw)
SY 3 1 3 0
q w
5
e r t y u
1 C6
i o !0
!1
!2
!3
Top ported
y Pilot valve option
q Series
3
5
7
SY3000
SY5000
SY7000
Nil
B
K Note)
!1 A, B port size
Standard (0.7 MPa)
Quick response type (0.7 MPa)
High pressure type (1.0 MPa)
Note) Select the metal seal type for high pressure
type.
w Type of actuation
1
2
3
4
5
2-position
3-position
A Note)
4-position dual
B Note) 3-port valve
C Note)
e Seal type
Rubber seal
Metal seal
r Pilot type
Nil
R
Internal pilot
External pilot
u Coil type
Nil
Standard
With power saving circuit
(Continuous duty type) Note 1) 2)
T
Note 1) Be sure to select the power saving circuit
type when the valve is continuously
energized for long periods of time.
Note 2) Be careful of the energizing time when
the power saving circuit is selected. For
details, refer to the SY series catalog
(CAT. ES11-103).
i Rated voltage
5
Port size
M5 x 0.8
1/8
1/4
SY3000 SY5000 SY7000
—
—
—
—
—
—
t Back pressure check valve (Built-in valve type)
None
Built-in
Note) Select the rubber seal type when the
back pressure check valve is built-in.
Manifold installed type is available if the
back pressure check valve is required for
a valve with metal seal. For ordering
example, refer to the SY series catalog
(CAT. ES11-103). However, it is not
recommended to use the built-in valve
type and the manifold installed type at
the same time because it will reduce the
flow.
∗ Select “Nil” for 3-position type and the SY7000.
C2
C3
C4
C6
C8
C10
C12
A, B port
ø2
ø3.2
ø4
ø6
ø8
ø10
ø12
SY3000 SY5000 SY7000
—
—
—
—
—
—
—
—
—
—
One-touch fitting (Inch)
N1
N3
N7
N9
N11
A, B port
ø1/8"
ø5/32"
ø1/4"
ø5/16"
ø3/8"
SY3000 SY5000 SY7000
—
—
—
—
—
—
24 VDC
o Light/surge voltage suppressor
and common specification
With light
Nil
H Note)
M5
01
02
One-touch fitting (Metric)
Single
Double
Closed center
Exhaust center
Pressure center
N.C./N.C.
N.O./N.O.
N.C./N.O.
Note) Select the rubber seal type for the 4-position
dual 3-port valve.
0
1
Thread piping
R
U
S
Z
NS
NZ
Surge voltage Common
suppressor specification
—
—
—
Non-polar
Positive
common
Negative
common
∗ Only “Z” and “NZ” types are available for with
the power saving circuit. Select a valve from
“R, U, S or Z” when the SI Unit specification is
“A2” (positive common). Select a valve from
“R,U, NS or NZ” when the SI Unit specification is “A2N” (negative common).
!0 Manual override
Nil
Non-locking
push
E
Push-turn
locking
(manual)
D
Push-turn
locking
(slotted)
F
Slide locking
(manual)
!2 A, B port thread type
Nil
F
N
T
Rc
G
NPT
NPTF
∗ Select “Nil” for M5.
!3 Type of mounting screw
Nil
B
K
Round head combination screw
Hexagon socket head cap screw
Round head combination screw
(Falling-out-prevention type) Note)
H
Hexagon socket head cap screw
(Falling-out-prevention type) Note)
Note) For “K” and “H”, the valve body cover has
a drop prevention construction to stop the
mounting screws from falling out when
the valve is removed for maintenance
etc.
∗ When ordering a valve individually, the
base gasket is not included.
Since the base gasket is attached to the
manifold, please order the base gasket
separately if it is needed for maintenance
service. For details, refer to the SY series
catalog (CAT. ES11-103).
∗ Select “Nil” or “K” for the optional individual
SUP/EXH spacer assembly or interface
regulator.
Protective class
class # (Mark:
61
)
Gateway Decentralized System
5 Port Solenoid Valve
Series SY3000
Type 10/Side Ported
Dimensions
D side
Series SY3000
U side
(8)
14 A
14 A
12 B
12 B
12 B
12 B
12 B
83
14 A
4.6
(40.9)
4.6
1.7
)
C6: 3.6
N7: 7.4
(4.9)
4 x M4 Mounting hole
(Fitting for the type with P/E ports on the U and/or D sides)
(
12.1
SI Unit
60.5
14 A
67.8
14 A
(35)
B A B A B A B A B A
92.6
(5.5)
Manual override
4(A) port side: Blue (for rubber seal)
: Gray (for metal seal)
2(B) port side: Yellow
Light/surge voltage suppressor
(L5)
L1
L2
34.5
1.5
(L4)
(DIN rail mounting hole pitch: 12.5)
(5.3)
(L3)
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: ø8, ø5/16"
E
P
B2
B2
B
A4
A4
A4
A
3/5
E
21.6
B2
A4
M12
17.5
46.3
15.5
(7.5)
18
40.2
22.2
B2
4
(Pitch)
P = 10.5
(17.8)
Gateway Decentralized System
2
(11.8)
3/5
1
10.6
P
13.6
1
1
43.2
60
0
63.1
(Station n)
M12
56.6
(Station 1)
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
: ø6, ø1/4"
Note) These figures show the “SS5Y3-10SA2-05D-C6”.
SY
103.5
63
3
114
73.5
4
124.5
5
135
6
7
8
9
10
11
12
13
14
15
16
145.5
156
166.5
177
187.5
198
208.5
219
229.5
240
250.5
210
84
94.5
105
115.5
126
136.5
147
157.5
168
178.5
189
199.5
135.5
148
148
160.5
173
185.5
198
210.5
223
223
235.5
248
260.5
273
285.5
125
137.5
137.5
150
162.5
175
187.5
200
212.5
212.5
225
237.5
250
262.5
275
16
17
12
13
14
15
16
17
18
12.5
13.5
14.5
15.5
16.5
S0700
2
L1
L2
L3
L4
L5
VQC
n: Stations
17.5
62
SV
For dimensions of Type 11/Bottom ported type
and Type 12/Top ported type, refer to the WEB
catalog or the SY series catalog (CAT. ES11103).
Series SY5000
Series SY5000
Type 10/Side Ported
Dimensions
D side
U side
BA
14 A
12 B
12 B
12 B
12 B
12 B
97.5
BA
14 A
(61.7)
4.7
5.5
(5.9)
(8.3)
8.7
81.2
BA
14 A
79.9
BA
14 A
(35)
(8)
BA
14 A
113.4
L1
10.9
(L5)
(5.5)
Manual override
4(A) port side: Blue (for rubber seal)
: Gray (for metal seal)
2(B) port side: Yellow
Light/surge voltage suppressor
4 x M5 Mounting hole
SI Unit
L2
34
(Fitting for the type with P/E ports on the U and/or D sides)
1.5
(L4)
(DIN rail mounting hole pitch: 12.5)
(5.3)
(L3)
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: ø10, ø3/8"
(Station 1)
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"
(Station n)
M12
A4
A4
A4
P
3/5
E
A
(7.5)
8.7
A4
1
B
17.5
M12
48
18
(Pitch)
P = 16
73.2
B2
56.6
B2
29.1
B2
E
4
12.4
33.4
B2
(11.8)
P
2
3/5
22.2
43.2
60
1
1
14.1
0
(20.5)
Note) These figures show the “SS5Y5-10SA2-05D-C8”.
n: Stations
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
L1
L2
L3
L4
L5
120.5
136.5
152.5
168.5
184.5
200.5
216.5
232.5
248.5
264.5
280.5
296.5
312.5
328.5
344.5
80
96
112
128
144
160
176
192
208
224
240
256
272
288
304
148
160.5
185.5
198
210.5
235.5
248
260.5
273
298
310.5
323
348
360.5
373
137.5
150
175
187.5
200
225
237.5
250
262.5
287.5
300
312.5
337.5
350
362.5
14
12
15
13
16
14
12.5
17
15
13.5
18
16
14.5
16.5
17.5
For dimensions of Type 11/Bottom ported type
and Type 12/Top ported type, refer to the WEB
catalog or the SY series catalog (CAT. ES11103).
63
Gateway Decentralized System
5 Port Solenoid Valve
Series SY7000
Series SY7000
Type 10/Side Ported
Dimensions
D side
U side
Manual override
4(A) port side: Blue (for rubber seal)
: Gray (for metal seal)
2(B) port side: Yellow
Light/surge voltage suppressor
(L5)
L1
12 B
12 B
12 B
12 B
12 B
96.7
(77.1)
(5.5)
5.5
24.1
(17.9)
(9.3)
(6)
SI Unit
34.2
115
B A
14 A
128.8
B A
14 A
3.9
B A
14 A
8.8
B A
14 A
79.9
B A
14 A
(35)
(8)
4 x M5 Mounting hole
(A, B port: ø12)
L2
(Fitting for the type with P/E ports on the U and/or D sides)
1.5
(L4)
(DIN rail mounting hole pitch: 12.5)
(L3)
(5.3)
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: ø12, ø1/2"
(Station 1)
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
: ø10, ø3/8"
: ø12
(Station n)
2
M12
B2
B2
B2
B
4
A4
A4
A4
A4
A
1
P
3/5
E
31.6
8.7
11.1
E
17.5
53
20.5
(21.7)
(Pitch)
P = 19
(10)
M12
82.7
B2
(14.3)
2
14.2
35.2
3/5
22.2
43.2
60
P
1
Note) These figures show the “SS5Y7-10SA2-05D-C10”.
Gateway Decentralized System
1
56.6
0
SY
3
4
5
6
7
8
9
10
11
12
13
14
15
16
134.7
153.7
172.7
191.7
210.7
229.7
248.7
267.7
286.7
305.7
324.7
343.7
362.7
381.7
400.7
113
132
151
170
189
208
227
246
265
284
303
322
341
360
160.5
94
185.5
198
223
235.5
260.5
273
298
310.5
335.5
348
373
398
410.5
435.5
150
175
187.5
212.5
225
250
262.5
287.5
300
325
337.5
362.5
387.5
400
425
13
16
12.5
15.5
12
15
12
15
11.5
14.5
17.5
12.5
15.5
14.5
S0700
2
L1
L2
L3
L4
L5
VQC
n: Stations
17.5
64
SV
For dimensions of Type 11/Bottom ported type
and Type 12/Top ported type, refer to the WEB
catalog or the SY series catalog (CAT. ES11103).
Gateway Decentralized System
5 Port Solenoid Valve
Series VQC1000
For detailed specifications, Common Precautions and Specific Product Precautions, refer to the WEB catalog or the VQC1000/2000 series catalog (CAT. ES11-101).
How to Order Manifold
VV5QC 1 1 08 C6 SDA2 N
q
q Valve stations
…
…
08 8 stations
01 1 station
16 16 stations
e
r
t
e SI Unit (Number of outputs, Max. number of valve stations)
Note
…
…
Stations
01 1 station
w
Double wiring
SD0
SDA2
Without SI Unit
16 outputs, 1 to 8 stations (16 stations Note))
Note) ( ): Maximum number of stations for mixed single and double wiring.
Mixed wiring, Specified layout Note)
(Available up to 16 solenoids)
Note) Specified layout: Indicate the wiring specifications on the manifold specification
sheet. (Note that 2-position double,
3-position and 4-position valves cannot
be used where single wiring has been
specified.) In addition, select the option
“K”.
w A, B port size
Metric size
C3
C4
C6
M5
CM Note 1)
L3
L4
L6
L5
B3
B4
B6
B5
LM Note 1)
MM Note 2)
Straight piping: ø3.2 One-touch fitting
Straight piping: ø4 One-touch fitting
Straight piping: ø6 One-touch fitting
Straight piping: M5 thread
Straight piping: Mixed sizes and with port plug
Top ported elbow: ø3.2 One-touch fitting
Top ported elbow: ø4 One-touch fitting
Top ported elbow: ø6 One-touch fitting
Top ported elbow: M5 thread
Bottom ported elbow: ø3.2 One-touch fitting
Bottom ported elbow: ø4 One-touch fitting
Bottom ported elbow: ø6 One-touch fitting
Bottom ported elbow: M5 thread
Elbow piping: Mixed sizes and with port plug
Mixed size for different types of piping, option installed
Inch size
N1
N3
N7
NM Note1)
LN1
LN3
LN7
BN1
BN3
BN7
LNM Note1)
BNM Note 2)
Straight piping: ø1/8" One-touch fitting
Straight piping: ø5/32" One-touch fitting
Straight piping: ø1/4" One-touch fitting
Straight piping: Mixed sizes and with port plug
Top ported elbow: ø1/8" One-touch fitting
Top ported elbow: ø5/32" One-touch fitting
Top ported elbow: ø1/4" One-touch fitting
Bottom ported elbow: ø1/8" One-touch fitting
Bottom ported elbow: ø5/32" One-touch fitting
Bottom ported elbow: ø1/4" One-touch fitting
Elbow piping: Mixed sizes and with port plug
Mixed size for different types of piping, option installed
Note 1) Indicate the sizes on the manifold specification sheet.
Note 2) When a combination of straight and
elbow piping is or when option such as
dual flow fitting assembly is mounted,
please mention the mounting conditions
in the Manifold Specification.
65
r SI Unit (Output polarity)
Nil
N
Positive common
Negative common
∗ Ensure a match with the common specification of
the valve to be used.
∗ Select “Nil” for without SI Unit.
t Option
Nil
B Note 1)
D
D0
D Note 2)
K Note 3)
N
R Note 4)
S Note 5)
None
With back pressure check valve (All stations)
With DIN bracket, DIN rail with standard length
With DIN bracket, without DIN rail
With DIN bracket, DIN rail for stations
Special wiring specification (Except double wiring)
With name plate
External pilot
Built-in silencer, Direct exhaust
∗ When multiple symbols are specified, indicate
them alphabetically. Example) -BRS
Note 1) When a back pressure check valve is
used only for specified station, specify
the back pressure check valve part
number, and specify the station number
to which the valve is mounted, on the
manifold specification sheet.
Note 2) : Specify a longer rail than the length
of valve stations.
Example) “-D08”
In this case, the valves will be mounted
on the DIN rail for 8 stations, regardless
of the number of manifold stations.
Note 3) When single wiring and double wiring
are mixed, specify wiring type of each
station on the manifold specification
sheet.
Note 4) For external pilot option “-R”, indicate
the external pilot specification “R” for
the applicable valves as well.
Note 5) Built-in silencer type does not satisfy
IP67.
Gateway Decentralized System
5 Port Solenoid Valve
Series VQC1000
How to Order Valves
VQC 1 1 0 0 N 5
A
B C
A Type of actuation
1
D E F
F Manual override
B Seal type
1
2-position single
A Note)
2
2-position double
B Note)
3
3-position closed center
C Note)
4
5
3-position exhaust center
3-position pressure center
0
1
4-position dual 3-port valve
(N.C./N.C.)
4-position dual 3-port valve
(N.O./N.O.)
4-position dual 3-port valve
(N.C./N.O.)
Metal seal
Rubber seal
Nil
Non-locking push
(tool required)
C Function
Nil
B
K Note 2)
N Note 3)
R Note 4)
Note) Only rubber seal type
A
Standard (0.4 W)
Quick response type (0.95 W)
High pressure type (1.0 MPa, 0.95 W)
Negative common
External pilot
Note 1) When multiple symbols are
specified, indicate them alphabetically. However,
combination of “B” and “K”
is not possible.
Note 2) Metal seal type only
Note 3) When the negative common
is specified for the SI Unit,
select and mount the valve
of negative common.
Note 4) Dual 3-port is not applicable.
D Coil voltage
5
24 VDC
B
B
Push-turn locking
(tool required)
A
B
C
Turn locking
(manual)
A
B
D
Slide locking
(manual)
E Light/surge voltage
suppressor
Gateway Decentralized System
Nil
With light/surge voltage suppressor
How to Order Manifold Assembly
Example
2-position single
2-position double
SY
U
si
de
Manifold base
ve
st
at
io
ns
VQC
VV5QC11-08C6SDA2N ···1 set (Manifold base part number)
∗ VQC1100N-51··············· 2 sets (2-position single part number)
∗ VQC1200N-51··············· 6 sets (2-position double part number)
D
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold base part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on the manifold specification sheet.
66
SV
si
de
1
2
3
4
5
6
7
8
V
S0700
al
500
EX ries
se
Series VQC1000
Dimensions
(L4)
(L3)
(5.25)
L2
L1
42.5
7
21
1.5
28
P = 10.5
63.5
(12)
1.5
Indicator
light
(5.5)
13
A B
A B
A B
A B
A
A
(40)
EX500
y2
series
SI Unit
Manual override
D side Station
4 x M4 Mounting hole
n
1 2 3 4 5 6 7 8
U side
R
R
3
3
X
X
B
B
B
B
B
B
B
B 12
A
A
A
A
A
A
A
25
1
7.5
1A
P
18.5
P
9.5
12
22.2
60
43.2
1
(7.5)
62.5
0
40.5
One-touch fitting
[1(P), 3(R) port]
Applicable tube O.D. C8: ø8
N9: ø5/16"
M12
(12)
75
66
(35)
64.4
COM
y9
93.5
A B
PWR
M12
M5 x 0.8
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø3.2, ø1/8"
ø4, ø5/32"
ø6, ø1/4"
20.5
34
P = 10.5
Formula: L1 = 10.5n + 45, L2 = 10.5n + 93.5 n: Stations (Maximum 16 stations)
n
L
L1
L2
L3
L4
67
1
55.5
2
66
3
76.5
4
87
5
97.5
6
7
8
9
10
11
12
13
14
15
16
108
118.5
129
139.5
150
160.5
171
181.5
192
202.5
213
261.5
104
114.5
125
135.5
146
156.5
167
177.5
188
198.5
209
219.5
230
240.5
251
125
137.5
150
162.5
175
187.5
187.5
200
212.5
225
237.5
250
250
262.5
275
287.5
135.5
148
160.5
173
185.5
198
198
210.5
223
235.5
248
260.5
260.5
273
285.5
298
Gateway Decentralized System
5 Port Solenoid Valve
Series VQC2000
For detailed specifications, Common Precautions and Specific Product Precautions, refer to the WEB catalog or the VQC1000/2000 series catalog (CAT. ES11-101).
How to Order Manifold
VV5QC 2 1 08 C8 SDA2 N
q
q Valve stations
…
…
08 8 stations
01 1 station
16 16 stations
e
r
t
e SI Unit (Number of outputs, Max. number of valve stations)
Note
…
…
Stations
01 1 station
w
Double wiring
SD0
SDA2
Without SI Unit
16 outputs, 1 to 8 stations (16 stations Note))
Note) ( ): Maximum number of stations for mixed single and double wiring.
Mixed wiring, Specified layout Note)
(Available up to 16 solenoids)
Note) Specified layout: Indicate the wiring specifications on the manifold specification
sheet. (Note that 2-position double,
3-position and 4-position valves cannot
be used where single wiring has been
specified.) In addition, select the option
“K”.
w A, B port size
C4
C6
C8
CM Note 1)
L4
L6
L8
B4
B6
B8
LM Note 1)
MM Note 2)
Straight piping: ø4 One-touch fitting
Straight piping: ø6 One-touch fitting
Straight piping: ø8 One-touch fitting
Straight piping: Mixed sizes and with port plug
Top ported elbow: ø4 One-touch fitting
Top ported elbow: ø6 One-touch fitting
Top ported elbow: ø8 One-touch fitting
Bottom ported elbow: ø4 One-touch fitting
Bottom ported elbow: ø6 One-touch fitting
Bottom ported elbow: ø8 One-touch fitting
Elbow piping: Mixed sizes and with port plug
Mixed size for different types of piping, option installed
Inch size
t Option
Nil
B Note 1)
D
D0
D Note 2)
K Note 3)
N
R Note 4)
S Note 5)
T Note 6)
None
With back pressure check valve (All stations)
With DIN bracket, DIN rail with standard length
With DIN bracket, without DIN rail
With DIN bracket, DIN rail for stations
Special wiring specification (Except double wiring)
With name plate
External pilot
Built-in silencer, Direct exhaust
P and R ports included on both sides of the U side
68
SV
∗ When multiple symbols are specified, indicate
them alphabetically. Example) -BRS
Note 1) When a back pressure check valve is
used only for specified station, specify
the back pressure check valve part
number, and specify the station number
to which the valve is mounted, on the
manifold specification sheet.
Note 2) : Specify a longer rail than the length
of valve stations.
Example) “-D08”
In this case, the valves will be mounted
on the DIN rail for 8 stations, regardless
of the number of manifold stations.
Note 3) When single wiring and double wiring
are mixed, specify wiring type of each
station on the manifold specification
sheet.
Note 4) For external pilot option “-R”, indicate
the external pilot specification “R” for
the applicable valves as well.
Note 5) Built-in silencer type does not satisfy
IP67.
Note 6) P and R ports are included on both
sides of U side (cylinder port and coil
side) with ø12 One-touch fittings.
S0700
Note 1) Indicate the sizes on the manifold
specification sheet.
Note 2) When a combination of straight and
elbow piping is or when option such as
dual flow fitting assembly is mounted,
please mention the mounting conditions
in the Manifold Specification.
Positive common
Negative common
∗ Ensure a match with the common specification
of the valve to be used.
∗ Select “Nil” for without SI Unit.
VQC
Straight piping: ø1/8" One-touch fitting
Straight piping: ø5/32" One-touch fitting
Straight piping: ø1/4" One-touch fitting
Straight piping: Mixed sizes and with port plug
Top ported elbow: ø1/8" One-touch fitting
Top ported elbow: ø5/32" One-touch fitting
Top ported elbow: ø1/4" One-touch fitting
Bottom ported elbow: ø1/8" One-touch fitting
Bottom ported elbow: ø5/32" One-touch fitting
Bottom ported elbow: ø1/4" One-touch fitting
Elbow piping: Mixed sizes and with port plug
Mixed size for different types of piping, option installed
Nil
N
SY
N1
N3
N7
NM Note 1)
LN1
LN3
LN7
BN1
BN3
BN7
LNM Note 1)
BNM Note 2)
r SI Unit (Output polarity)
Gateway Decentralized System
Metric size
Series VQC2000
How to Order Valves
VQC 2 1 0 0 N 5
A
B C
A Type of actuation
1
D E F
F Manual override
B Seal type
1
2-position single
A Note)
2
2-position double
B Note)
3
3-position closed center
C Note)
4
5
3-position exhaust center
3-position pressure center
0
1
4-position dual 3-port valve
(N.C./N.C.)
4-position dual 3-port valve
(N.O./N.O.)
4-position dual 3-port valve
(N.C./N.O.)
Metal seal
Rubber seal
Nil
Non-locking push
(tool required)
C Function
Nil
B
K Note 2)
N Note 3)
R Note 4)
Note) Only rubber seal type
Standard (0.4 W)
Quick response type (0.95 W)
High pressure type (1.0 MPa, 0.95 W)
Negative common
External pilot
Note 1) When multiple symbols are
specified, indicate them alphabetically. However,
combination of “B” and “K”
is not possible.
Note 2) Metal seal type only
Note 3) When the negative common is specified for the SI
Unit, select and mount the
valve of negative common.
Note 4) Dual 3-port is not applicable.
D Coil voltage
5
B
Push-turn locking
(tool required)
C
Turn locking
(manual)
D
Slide locking
(manual)
24 VDC
E Light/surge voltage
suppressor
Nil
With light/surge voltage
suppressor
How to Order Manifold Assembly
Example
2-position single
2-position double
V
al
ve
st
at
io
ns
U
si
de
Manifold base
VV5QC21-08C6SDA2N······1 set (Manifold base part number)
∗ VQC2100-51····················2 sets (2-position single part number)
∗ VQC2200-51····················6 sets (2-position double part number)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
D
si
de
1
2
3
4
5
6
7
8
500
EX ries
se
69
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold base part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on the manifold specification sheet.
Gateway Decentralized System
5 Port Solenoid Valve
Series VQC2000
Dimensions
(L4)
(L3)
(5.25)
L2
L1
38.5
74
38.5
0.9
1
Double sided type
13
Indicator light
y10.5
1
(5.5)
(53.5)
80
(35)
COM
105.5
120
PWR
y3.5
EX500
series
SI Unit
D side
Manual override
1
Station
2
3
y5.5
(12)
P = 16
34.5
4 x M5 Mounting hole
4
5
6
7
U side
n
8
M12
One-touch fitting
[1(P), 3(R) port]
Applicable tube O.D. C10: ø10
N11: ø3/8"
C12: ø12
(Double sided type)
M12
R
(
R
)
Gateway Decentralized System
10
X
B
B
B
B
B
B
B
B
P
P
12
30
22.2
12
A
A
A
A
A
A
A
1
(7.5)
13.5
A
49.5
3
X
1
1
(12)
25
43.2
3
60
76.5
0
25
P = 16
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
45
SY
VQC
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
73
89
105
121
137
153
169
185
201
217
233
249
265
281
297
313
118
134
150
166
182
198
214
230
246
262
278
294
310
326
342
358
137.5
162.5
175
187.5
212.5
225
237.5
250
275
287.5
300
325
337.5
350
362.5
387.5
148
173
185.5
198
223
235.5
248
260.5
285.5
298
310.5
335.5
348
360.5
373
398
70
SV
L1
L2
L3
L4
1
S0700
Formula: L1 = 16n + 57, L2 = 16n + 102 n: Stations (Maximum 16 stations)
n
L
Gateway Decentralized System
5 Port Solenoid Valve
Series VQC4000
For detailed specifications, Common Precautions and Specific Product Precautions, refer to the WEB catalog or the VQC4000/5000 series catalog (CAT. ES11-108).
How to Order Manifold
VV5QC 4 1 08 02
q
q Valve stations
Note
…
…
…
…
16 16 stations
e
r
t
y
r SI Unit (Number of outputs, Max. number of valve stations)
Stations
01 1 station
08 8 stations
01 1 station
w
SDA2 N
Double wiring
SD0
SDA2
Without SI Unit
16 outputs, 1 to 8 stations (16 stations Note))
Note) ( ): Maximum number of stations for mixed single and double wiring.
Mixed wiring, Specified layout Note)
(Available up to 16 solenoids)
Note) Specified layout: Indicate the wiring specifications on the manifold specification
sheet. (Note that 2-position double,
3-position and 4-position valves cannot
be used where single wiring has been
specified.) In addition, select the option
“K”.
w Cylinder port size
C6
C8
C10
C12
N7
N9
N11
02
03
B
CM
With ø6 One-touch fitting
With ø8 One-touch fitting
With ø10 One-touch fitting
With ø12 One-touch fitting
ø1/4" One-touch fitting
ø5/16" One-touch fitting
ø3/8" One-touch fitting
1/4 Note)
3/8 Note)
Bottom ported 1/4 Note)
Mixed sizes
Note) Compatible with Rc, G, NPT/NPTF.
Part number displayed is as shown below.
e Thread type
Nil
F
N
T
71
Rc
G
NPT
NPTF
t SI Unit (Output polarity)
Nil
N
Positive common
Negative common
∗ Select “Nil” for without SI Unit.
y Option
Nil None
K Note) Special wiring specification (Except double wiring)
Note) When single wiring and double wiring are
mixed, specify wiring type of each station
on the manifold specification sheet.
Gateway Decentralized System
5 Port Solenoid Valve
Series VQC4000
How to Order Valves
VQC 4 1 0 0
A
5
B C
A Type of actuation
1
2
3
2-position single
2-position double
3-position closed center
D E F
C Function
4
5
6 Note)
F Manual override
Nil Note 1) Standard (0.95 W)
Low wattage type (0.4 W)
Y
External pilot
R Note 2)
3-position exhaust center
3-position pressure center
3-position double check
∗ When multiple symbols are specified, indicate them alphabetically.
Note 1) When the power is energized continuously, refer to
“Specific Product Precautions 1” in the WEB catalog
or the VQC4000/5000 series catalog (CAT. ES11108).
Note 2) For details about the external pilot type, refer to the
WEB catalog or the
VQ4000/5000 series catalog (CAT. ES11-104). In addition, an external pilot type
cannot be combined with
the double check spacer.
Note) For double check type, refer to the WEB catalog or the VQC4000/5000
series catalog (CAT. ES11-108).
B Seal type
0
1
1
Metal seal
Rubber seal
Nil
Non-locking
push
(tool required)
B
Push-turn
locking
(tool required)
D Coil voltage
5
24 VDC
E Light/surge voltage
C
Turn locking
(manual)
suppressor
Nil
Gateway Decentralized System
E
With
Without light, with surge
voltage suppressor
How to Order Manifold Assembly
Example
2-position single
2-position double
de
SY
U
si
Manifold base
1
D
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold base part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on the manifold specification sheet.
72
SV
si
de
2
3
4
5
6
7
8
V
al
S0700
ve
st
at
io
ns
VQC
VV5QC41-0802SDA2N·········1 set (Manifold base part number)
∗ VQC4100-51 ······················4 sets (2-position single part number)
∗ VQC4200-51 ······················4 sets (2-position double part number)
Series VQC4000
Dimensions
L2
(6.5)
L1
39.5
P = 25
Indicator light Manual override
65.5
AB AB AB AB AB A
A
9
A
A
A
A
B
A
B
B
B
B
5
6
7
A
A
143
163
PWR
COM
9
EX500
series
10
SI Unit
D side
1
Station
2
3
4
8
U side
n
3/4"
3(R) port
1/2"
1(P) port
M12
SMC
SMC
SMC
SMC
1/8"
External pilot port
11.5
1/8"
PE. port
M12
43.5
12
20.6
1
15.7
60
42.7
0
95.5
SMC
101.2
SMC
77.3
SMC
27.9
33.5
37.5
1/4", 3/8"
C6, C8, C10, C12, N7, N9, N11
4(A), 2(B) port
45.2
Formula: L1 = 25n + 106, L2 = 25n + 152 n: Stations (Maximum 16 stations)
n
L
L1
L2
73
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
131
156
181
206
231
256
281
306
331
356
381
406
431
456
481
506
177
202
227
252
277
302
327
352
377
402
427
452
477
502
527
552
Gateway Decentralized System
5 Port Solenoid Valve
Series VQC5000
For detailed specifications, Common Precautions and Specific Product Precautions, refer to the WEB catalog or the VQC4000/5000 series catalog (CAT. ES11-108).
How to Order Manifold
VV5QC 5 1 08 03
q
q Valve stations
Note
…
…
…
…
12 12 stations
e
r
t
y
r SI Unit (Number of outputs, Max. number of valve stations)
Stations
01 1 station
08 8 stations
01 1 station
w
SDA2 N
Double wiring
SD0
SDA2
Without SI Unit
16 outputs, 1 to 8 stations (12 stations Note))
Note) ( ): Maximum number of stations for mixed single and double wiring.
Mixed wiring, Specified layout Note)
(Available up to 12 solenoids)
Note) Specified layout: Indicate the wiring specifications on the manifold specification
sheet. (Note that 2-position double,
3-position and 4-position valves cannot
be used where single wiring has been
specified.) In addition, select the option
“K”.
w Cylinder port size
3/8 Note)
1/2 Note)
Bottom ported 1/4 Note)
Mixed sizes
Note) Compatible with Rc, G, NPT/NPTF.
Part number displayed is as shown below.
t SI Unit (Output polarity)
Nil
N
Positive common
Negative common
∗ Select “Nil” for without SI Unit.
y Option
Nil None
K Note) Special wiring specification (Except double wiring)
Note) When single wiring and double wiring are
mixed, specify wiring type of each station
on the manifold specification sheet.
e Thread type
Nil
F
N
T
Rc
G
NPT
NPTF
Gateway Decentralized System
03
04
B
CM
SY
VQC
S0700
SV
74
Series VQC5000
How to Order Valves
VQC 5 1 0 0
A
5
B C
A Type of actuation
1
2
3
2-position single
2-position double
3-position closed center
D E F
C Function
4
5
6 Note)
F Manual override
Nil Note 1) Standard (0.95 W)
Y Note 1) Low wattage type (0.4 W)
External pilot
R Note 2)
3-position exhaust center
3-position pressure center
3-position double check
∗ When multiple symbols are specified, indicate them alphabetically.
Note 1) When the power is energized continuously, refer to
“Specific Product Precautions 1” in the WEB catalog
or the VQC4000/5000 series catalog (CAT. ES11108).
Note 2) For details about the external pilot type, refer to the
WEB catalog or the
VQ4000/5000 series catalog (CAT. ES11-104). In addition, an external pilot type
cannot be combined with
the double check spacer.
Note) For double check type, refer to the WEB catalog or the VQC4000/5000
series catalog (CAT. ES11-108).
B Seal type
0
1
1
Metal seal
Rubber seal
Nil
Non-locking push
(tool required)
B
Push-turn locking
(tool required)
D Coil voltage
5
24 VDC
E Light/surge voltage
C
Turn locking
(manual)
suppressor
Nil
E
With
Without light, with surge
voltage suppressor
How to Order Manifold Assembly
Example
2-position single
si
d
e
2-position double
1
D
si
2
de
3
4
5
6
V
al
ve
st
at
io
ns
U
Manifold base
VV5QC51-0603SDA2N ······1 set (Manifold base part number)
∗ VQC5100-51····················2 sets (2-position single part number)
∗ VQC5200-51····················2 sets (2-position double part number)
∗ VQC5300-51····················2 sets (3-position closed center part number)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold base part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on the manifold specification sheet.
75
Gateway Decentralized System
Series VQC5000
5 Port Solenoid Valve
Dimensions
L2
L1
10
Indicator light
P = 41
B
179
106
9
107.8
B
29.5 29.5
B
5 R1
B
SI Unit
1 P
A
A
A
A
A
B
EX500
3 R2
PE
61
9
COM
179 (Single, Double, 3-position: Rubber seal type)
A
A B
A B
A B
PWR
184.5 (3-position: Metal seal type)
Manual override
A B
59.5
35
3/4"
1(P), 5(R1)
3(R2) port
12
21
1/8"
PE. port
47.5
2
1
Station
3
4
5
U side
n
6
M5 x 0.8 Ground screw
2
B 2
B 2
B 2
B 2
B 2
117
D side
1/2"
3(R) port
M12
B
4
A 4
A 4
A 4
M12
1/2"
1(P) port
A 4
A 4
A
3/8", 1/2"
4(A), 2(B) port
34
34.5
48
69
51
55.5
X
22
12
17
1
15.5
3
19
60
53.7
0
1
1/8"
External pilot port
68.5
69.5
Gateway Decentralized System
Formula: L1 = 41n + 77, L2 = 41n + 122 n: Stations (Maximum 12 stations)
n
L
L1
L2
1
2
3
4
5
6
7
8
9
10
11
12
118
159
200
241
282
323
364
405
446
487
528
569
163
204
245
286
327
368
409
450
491
532
573
614
SY
VQC
S0700
SV
76
Gateway Decentralized System
5 Port Solenoid Valve
Series S0700
For detailed specifications, Common Precautions and Specific Product Precautions, refer to the WEB catalog or the S0700 series catalog (CAT. ES11-88).
How to Order Manifold
SS0750 08 C4 C8 SDA2 N B
q
q Valve stations
…
…
08 8 stations
01 1 station
16 16 stations
e
r
t
y
r SI Unit (Number of outputs, Max. number of valve stations)
Note
…
…
Stations
01 1 station
w
Double wiring
SD0
SDA2
Without SI Unit
16 outputs, 1 to 8 stations (16 stations) Note)
Note) ( ): Maximum number of stations for mixed single and double wiring.
Mixed wiring, Specified layout Note)
(Available up to 16 solenoids)
Note) Specified layout: Indicate the wiring specifications on the manifold specification
sheet. (Note that 2-position double,
3-position and 4-position valves cannot
be used where single wiring has been
specified.) In addition, select the option
“K”.
w A, B port size
Metric size
C2
C3
C4
CM Note)
ø2 One-touch fitting
ø3.2 One-touch fitting
ø4 One-touch fitting
Mixed sizes and with port plug
Inch size
N1
N3
NM Note)
ø1/8" One-touch fitting
ø5/32" One-touch fitting
Mixed sizes and with port plug
Note) Indicate the sizes on the manifold
specification sheet.
e P, R port size
Metric size
Nil
C6
C8
ø8 One-touch fitting Note)
ø6 One-touch fitting
ø8 One-touch fitting
Inch size
N7
N9
ø1/4" One-touch fitting
ø5/16" One-touch fitting
Note) When A and B ports are inch size, the
One-touch fitting will be changed to
ø5/16".
77
t SI Unit (Output polarity)
Nil
N
Positive common
Negative common
∗ Ensure a match with the common specification
of the valve to be used.
∗ Select “Nil” for without SI Unit.
y Option
Nil
B Note 1)
D
D0
D Note 2)
K Note 3)
N
R Note 4)
S
None
With back pressure check valve (All stations)
With DIN bracket, DIN rail with standard length
With DIN bracket, without DIN rail
With DIN bracket, DIN rail for stations
Special wiring specification (Except double wiring)
With name plate
External pilot
Built-in silencer
∗ When multiple symbols are specified, indicate
them alphabetically. Example) “-BKN”
Note 1) When a back pressure check valve is
used only for specified station, specify
the back pressure check valve part
number, and specify the station number
to which the valve is mounted, on the
manifold specification sheet.
Note 2) : Specify a longer rail than the length
of valve stations.
Example) “-D08”
In this case, the valves will be mounted
on the DIN rail for 8 stations, regardless
of the number of manifold stations.
Note 3) When single wiring and double wiring
are mixed, specify wiring type of each
station on the manifold specification
sheet.
Note 4) For external pilot option “-R”, indicate
the external pilot specification “R” for
the applicable valves as well.
Gateway Decentralized System
5 Port Solenoid Valve
Series S0700
How to Order Valves
S07 1 0
A
A Note)
B
C
B Function
A Type of actuation
1
2
5
2-position single
2-position double
4-position dual 3-port (N.C. + N.C.)
[Exhaust center]
C Rated voltage
Nil
R Note)
5
Internal pilot
External pilot
24 VDC
Note) For external pilot, select “1” 2-position
single or “2” 2-position double.
4-position dual 3-port (N.O. + N.O.)
B Note) [Pressure center]
C Note) 4-position dual 3-port (N.C. + N.O.)
Note) For 4-position dual 3-port, select “Nil”
internal pilot.
Gateway Decentralized System
How to Order Manifold Assembly
Example
2-position single
Blanking plate
io
ns
U
si
de
Manifold base
0
50
2
1
de
si
D
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold base part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on the manifold specification sheet.
VQC
2-position double
SS0750-08C4SDA2·········1 set (Manifold base part number)
∗ S0710-5 ························3 sets (2-position single part number)
∗ S0720-5 ························4 sets (2-position double part number)
∗ SS0700-10A-1 ··············1 set (Blanking plate part number)
SY
3
St
at
EX
S0700
SV
78
Series S0700
Dimensions
L4
L3
5.25
L2
L1
(12)
4.4
(n – 1) × 8.5
1.5
12.8
8.5
60
Light
13
(5.5)
Manual override
PWR
14
14
14
14
14
14
14
14
S0710-5
S0710-5
S0710-5
S0720-5
S0720-5
S0720-5
S07A0-5
S07A0-5
12
12
12
12
12
72
62
39
(35)
COM
y4
5
EX500
series
SI Unit
4 x M4 Mounting hole
D side
2
3
4
5
6
7
8
n
U side
n
L1
L2
L3
L4
79
2
48
91
17.5
9.6
6.5
(7.5)
Dimensions
L
17.2
8.5
One-touch fitting
[1(P), 3(R) port]
Applicable tube O.D.: ø6, ø1/4"
ø8, ø5/16"
33.6
M12
22.2
60
1
(12)
43.2
M12
Station
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø2
ø3.2, ø1/8"
ø4, ø5/32"
Formula: L1 = 8.5n + 31, L2 = 8.5n + 74 n: Stations (Maximum 16 stations)
3
4
5
6
7
8
9
10
11
12
13
14
15
16
56.5
65
73.5
82
90.5
99
107.5
116
124.5
133
141.5
150
158.5
167
99.5
108
116.5
125
133.5
142
150.5
159
167.5
176
184.5
193
201.5
210
112.5
125
137.5
137.5
150
162.5
162.5
175
187.5
187.5
200
212.5
212.5
225
237.5
123
135.5
148
148
160.5
173
173
185.5
198
198
210.5
223
223
235.5
248
Gateway Decentralized System
5 Port Solenoid Valve
®
Series SV1000/2000/3000/4000
For detailed specifications, Common Precautions and Specific Product Precautions, refer to the WEB catalog or the SV series catalog (CAT. ES11-81).
How to Order Manifold
q
Tie-rod base
o
SS5V 1 W10S A2W D 05 U
Cassette base
SS5V 1 W16S A2W D 05 U
q Series
y SUP/EXH block assembly
1
2
3
4
Nil
S
R
RS
SV1000
SV2000
SV3000
SV4000
SV1000
SV2000
i DIN rail length specified
Without SI Unit
16 outputs, Positive common,
1 to 8 stations (16 stations) Note)
A2W
Note) ( ): Maximum number of stations for mixed
single and double wiring.
r Valve stations
Stations
…
…
…
…
16 16 stations
Double wiring Note 1)
Direct mounting
With DIN bracket, DIN rail with standard length
With DIN bracket, without DIN rail
With DIN bracket, DIN rail for 3 stations
D16 Note) With DIN bracket, DIN rail for 16 stations
Note) Specify a longer rail than the length of
valve stations.
∗ If the DIN rail must be mounted without an SI
Unit, select “D0” and order the DIN rail
separately. Refer to L3 of the dimensions for
the DIN rail length. For the DIN rail part
number, refer to the WEB catalog or the SV
series catalog (CAT. ES11-81).
Note) Specify a longer rail than the length of
valve stations.
∗ If the DIN rail must be mounted without an SI
Unit, select “D0” and order the DIN rail
separately. Refer to L3 of the dimensions for
the DIN rail length. For the DIN rail part
number, refer to the WEB catalog or the SY
series catalog (CAT. ES11-103).
u A, B port size
Metric size
layout Note 2)
Mixed wiring, Specified
(Available up to 16 solenoids)
Inch size
P, E port
Applicable series
ø8
One-touch fitting
SV1000
ø10
One-touch fitting
SV2000
ø12
One-touch fitting
SV3000
ø12
One-touch fitting
Rc3/8
G3/8
SV4000
Symbol
N1
N3
N7
N3
N7
N9
N7
N9
N11
N9
N11
02N
03N
02T
03T
M Note)
A, B port
ø1/8" One-touch fitting
ø5/32" One-touch fitting
ø1/4" One-touch fitting
ø5/32" One-touch fitting
ø1/4" One-touch fitting
ø5/16" One-touch fitting
ø1/4" One-touch fitting
ø5/16" One-touch fitting
ø3/8" One-touch fitting
ø5/16" One-touch fitting
ø3/8" One-touch fitting
NPT1/4
NPT3/8
NPTF1/4
NPTF3/8
A, B port mixed
P, E port
Applicable series
ø5/16"
One-touch fitting
SV1000
ø3/8"
One-touch fitting
SV2000
ø3/8"
One-touch fitting
SV3000
ø3/8"
One-touch fitting
NPT3/8
SV4000
NPTF3/8
80
SV
Note) Indicate the sizes on the manifold specification sheet.
∗ The X and PE port size of external pilot type [R, RS] are ø4 (mm) or ø5/32" (inch) for the
SV1000/2000 series, and ø6 (mm) or ø1/4" (inch) for the SV3000/4000 series.
S0700
U side (2 to 10 stations)
D side (2 to 10 stations)
Both sides (2 to 16 stations)
A, B port
C3 ø3.2 One-touch fitting
C4 ø4 One-touch fitting
C6 ø6 One-touch fitting
C4 ø4 One-touch fitting
C6 ø6 One-touch fitting
C8 ø8 One-touch fitting
C6 ø6 One-touch fitting
C8 ø8 One-touch fitting
C10 ø10 One-touch fitting
C8 ø8 One-touch fitting
C10 ø10 One-touch fitting
C12 ø12 One-touch fitting
02 Rc1/4
03 Rc3/8
02F G1/4
03F G3/8
M Note) A, B port mixed
VQC
t P, E port entry
Symbol
SY
Note 1) Double wiring: single, double, 3-position
and 4-position valves can be used on all
manifold stations.
Use of a single solenoid will result in an
unused control signal. If this is not
desired, order with a specified layout.
Note 2) Specified layout: Indicate the wiring
specifications on the manifold specification sheet. (Note that double,
3-position and 4-position valves cannot
be used where single wiring has been
specified.)
U
D
B
16 Note) With DIN bracket, DIN rail for 16 stations
Nil
D
D0
D3 Note)
Note
02 2 stations
08 8 stations
02 2 stations
i
Gateway Decentralized System
Max. number of valve stations)
Nil With DIN bracket, DIN rail with standard length
3 Note) With DIN bracket, DIN rail for 3 stations
…
e SI Unit (Number of outputs, Output polarity,
…
1
2
u
o Mounting
Internal pilot
Internal pilot, Built-in silencer Note)
External pilot
External pilot, Built-in silencer Note)
Note) When the built-in silencer type is used,
keep the exhaust port from coming in
direct contact with water or other liquids.
w Series
0
r t y
…
e
…
w
Series SV1000/2000/3000/4000
How to Order Valves
SV 1 1 0 0
A B
1
2
3
4
SV1000
SV2000
SV3000
SV4000
B Type of actuation
A Note)
B Note)
C Note)
C D
E
F G
D Back pressure check valve
A Series
1
2
3
4
5
5 F
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual 3-port valve (N.C./N.C.)
4-position dual 3-port valve (N.O./N.O.)
4-position dual 3-port valve (N.C./N.O.)
Note) Select the SV1000 or SV2000 series for
the 4-position dual 3-port valve.
∗ Select the internal pilot type for the 4-position
dual 3-port valve.
Nil
K
I
G Manual override
Nil
None
Built-in
Non-locking push
∗ Built-in back pressure check valve type is
applicable to the SV1000 series only.
∗ The product with a back pressure check valve
is not available for 3-position valves.
∗ Refer to the WEB catalog for built-in back
pressure check valve type.
D
E Rated voltage
5
Push-turn locking
(slotted)
24 VDC
F Light/surge voltage suppressor
U
R
With light/surge voltage suppressor
Without light, with surge voltage suppressor
C Pilot type
Nil
R
H
H Manifold block
If stations are to be added, order the product
with manifold block.
(For details, refer to the WEB catalog.)
Internal pilot
External pilot
I Made to Order
Nil
X90
—
Main valve fluororubber specification
(For details, refer to the WEB catalog.)
How to Order Manifold Assembly
Example
2-position double
2-position single
Us
ide
M
R
CO
PW
SS5V1-W16SA2WD-06B-C6 ·····1 set (Manifold base part number)
∗ SV1100-5FU ····························4 sets (2-position single part number)
∗ SV1200-5FU ····························2 sets (2-position double part number)
ns
tio
ta
S
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
3
2
1
81
Ds
ide
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold base part number, state the valves to be mounted in
order from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on the manifold specification sheet.
Gateway Decentralized System
Series SV1000
5 Port Solenoid Valve
Series SV1000
Cassette Base
Dimensions
With External Pilot Specification
C2
PE
4A
10
4
E
2B
59
45.5
4A
2B
35
2
P
29.2
52.7
4A
2B
1
PE
A
35
E
1
P
4A
C2
4A
4A
4A
4
E
B
2B
2B
2B
28.6
23
12.6
1
P
4A
2B
35
2
P
1
X
2B
One-touch fitting
[1(P), 3/5(E) port] Note 1)
Applicable tube O.D.: ø8
ø5/16"
8.4
A
18.1
B
46.7
11.8
35
13.5
E
P = 10.5
22.3
X
C1
C1
2 x M12
U side
(C6: 3.2)
(N7: 7)
SI Unit
9.5
(4.9)
D side
(L4)
L3
One-touch fitting
[PE: Pilot EXH port]
Applicable tube O.D.: ø4
ø5/32"
One-touch fitting
[X: External pilot port] Note 2)
Applicable tube O.D.: ø4
ø5/32"
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø3.2, ø1/8"
ø4, ø5/32"
ø6, ø1/4"
35
26.2
36.9
Manual override
4(A) port side: Orange
2(B) port side: Green
42.3
58.4
A
PWR COM
A
B
A
B
A
A
A
A
92.2
83.7
28.8
18
B
B
B
B
B
5.5
8
Silencer
L2
5
64.2
77.5
4A
4A
4
3/5
E
2B
2B
2B
2
P
P 1
41
1
P
4A
B
78
A
3/5
1
E 3
(Station 1)
E
(Station n)
42
L1
Individual EXH spacer
Light/surge voltage suppressor
Interface regulator
SV1:00-:-05
B
91.9
100.4
102.9
111.4
109.5
118
B
A
B
A
A
B
A
A
A
A
B
B
B
A
VQC
Note 1) When P, E port outlets are indicated on the U side or D side, the P, E ports on the
opposite side are plugged.
Note 2) External pilot port positions and silencer discharge port positions are the same as P, E
port outlet positions.
Dimensions for the SV1300--
n
L
3
n: Stations
4
5
6
7
8
9
10
11
12
13
14
15
16
135.5 148
160.5 173
173
185.5 198
210.5 223
235.5 235.5 248
260.5 273
285.5
125
137.5 150
162.5 162.5 175
187.5 200
212.5 225
225
237.5 250
262.5 275
106.5 117
127.5 138
148.5 159
169.5 180
190.5 201
211.5 222
232.5 243
253.5
14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12
13
14
15
16
SV
L1
L2
L3
L4
2
S0700
L: Dimensions
SY
B
19.7
7.5
63
48
68.2
Interface regulator
SV1:00-:-06
Max.14
Individual SUP spacer
Gateway Decentralized System
With Option
(Rail mounting pitch: 12.5)
82
Series SV2000
Series SV2000
Cassette Base
Dimensions
With External Pilot Specification
P
X
C1
4A
2B
4A
2B
4
2B
2
1
E
3/5
1
P
PE
PE
67.5
53.9
4A
29.2
52.7
2B
E
C2
P
3/5
1
4A
A
2B
B
4A
4A
2B
4A
2B
4
2B
E
12.5
34.6
31.5
15.9
4A
B
X
A
3/5
2
P
1
C1
One-touch fitting
[1(P), 3/5(E) port] Note 1)
Applicable tube O.D.: ø10
ø3/8"
9.5
3/5
18.8
E
48
11.8
C2
P = 16 17.5
23.5
2 x M12
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
One-touch fitting
[PE: Pilot EXH port] Note 2)
Applicable tube O.D.: ø4
ø5/32"
One-touch fitting
[X: External pilot port]
Applicable tube O.D.: ø4
ø5/32"
D side
U side
(L4)
SI Unit
B
B
B
B
B
A
A
A
A
Manual override
4(A) port side: Orange
2(B) port side: Green
42.3
B
A
A
PWRCOM
115.5
102.9
39.5
27.3
35
5.5
B
A
69.1
26.2
8
43.1
44.5
9.5
(5.3)
(4.9)
L3
Silencer
L2
5
(Rail mounting pitch: 12.5)
L1
4A
4A
2B
4
V
5
2B
V
3
E
2
E
P
3/5
1
1
P
A
A
A
B
A
B
A
B
A
B
A
A
19.7
n: Stations
4
5
6
7
8
9
10
11
12
13
14
15
16
148
173
185.5 198
210.5 235.5 248
260.5 285.5 298
310.5 323
348
360.5 373
137.5 162.5 175
187.5 200
225
237.5 250
275
287.5 300
312.5 337.5 350
362.5
122.5 138.5 154.5 170.5 186.5 202.5 218.5 234.5 250.5 266.5 282.5 298.5 314.5 330.5 346.5
13
17.5 15.5 14
12
16.5 15
13
17.5 16
14
12.5 17
15
13.5
Max. 21
7.5
B
83
3
B
L1
L2
L3
L4
2
B
L: Dimensions
n
Interface regulator
SV2000-:-00
B
Note 1) When P, E port outlets are indicated on the U side or D side, the P, E ports on
the opposite side are plugged.
Note 2) External pilot port positions and silencer discharge port positions are the same
as P, E port outlet positions.
L
Interface regulator
SV2000-:-M1
127.6
145.6
Individual EXH spacer
68.2
71.5
56.5
Individual SUP spacer
92.3
94.5
54.5
79
2B
86.5
1
P
4A
A
B
(Station 1)
3/5
(Station n)
Light/surge voltage suppressor
E
50.5
With Option
Gateway Decentralized System
Series SV1000
5 Port Solenoid Valve
Series SV1000
Tie-rod Base
Dimensions
With External Pilot Specification
P = 10.5
13.5
46.9
18.3
14.1
8.4
8.6
10
11.8
PE
A4
A
B2
B2
B2
B2
35
B
P
1
PE
1
4
19.7
24.6
43.2
A4
56.5
43
P
A4
E
2
C2
A4
A4
A4
A4
A4
A
23
4
E
E
35
2
C2
P
B2
B2
B2
B2
35
B
P
1
1
C1
C1
L3
(L4)
L5
X
2 x M12
One-touch fitting
[PE: Pilot EXH port]
Applicable tube O.D.: ø4
ø5/32"
One-touch fitting
[X: External pilot port] Note 2)
Applicable tube O.D.: ø4
ø5/32"
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø3.2, ø1/8"
ø4, ø5/32"
ø6, ø1/4"
U side
35
X
E
One-touch fitting
[1(P), 3/5(E) port] Note 1)
Applicable tube O.D.: ø8
ø5/16"
D side
(4.9)
(C6: 3.2)
(N7: 7)
34.1
5.5
35
68.5
92.6
A
8
L2
5
With Option
74
B2
3/5
1
P
E3
(C6: 3.2)
(N7: 7)
Interface regulator
SV1:00-:-06
B
B
A
A
91.9
100.4
102.9
111.4
109.5
118
VQC
Note 1) When P, E port outlets are indicated on the U side or D side, the P, E ports on the
opposite side are plugged.
Note 2) External pilot port positions and silencer discharge port positions are the same as P, E
port outlet positions.
B
A
A
A
B
A
A
B
B
B
B
A
Dimensions for the SV1300--
n
L
3
n: Stations
4
5
6
7
8
135.5 148
148
160.5 173
185.5 198
125
137.5 137.5 150
162.5 175
187.5
102.6 113.1 123.6 134.1 144.6 155.1 165.6
16.5 17.5 12
13
14
15
16
63
73.5 84
94.5 105
115.5 126
9
10
11
12
13
14
15
16
210.5
200
176.1
17
136.5
210.5
200
186.6
12
147
223
212.5
197.1
13
157.5
235.5
225
207.6
14
168
248
237.5
218.1
15
178.5
260.5
250
228.6
16
189
273
262.5
239.1
17
199.5
273
262.5
249.6
11.5
210
SV
L1
L2
L3
L4
L5
2
S0700
L: Dimensions
SY
90
(7.5)
Interface regulator
SV1:00-:-05
Max. 14
P1
B
11.8
38.5
60.7
B2
74.5
B2
58.7
E
2
37.5
A
59.5
45.5
10
1
P
A4
Individual EXH spacer
Individual SUP spacer
A4
(Station 1)
A4
(Station n)
Light/surge voltage suppressor
4
L1
Gateway Decentralized System
(Rail mounting pitch: 12.5)
3/5
4 x ø4.3
Silencer
E
4.6
Manual override
4(A) port side: Orange
2(B) port side: Green
9.6
29.6
39.6
PWR COM
A
B
A
B
A
A
A
A
B
B
B
B
B
92.2
83
83.7
10.8
9.5
SI Unit
84
Series SV2000
Series SV2000
Tie-rod Base
Dimensions
With External Pilot Specification
P = 16 17.5
46.5
15.8
11.8
9.5
4A
4
E
P
2B
2B
63.5
49.9
4A
2B
3/5
2
1
P
PE
X
1
A
3/5
E
1
P
C2
4A
4A
4A
4A
4
E
B
2B
2B
2B
2B
3/5
2
P
1
C1
PE
One-touch fitting
[PE: Pilot EXH port] Note 2)
Applicable tube O.D.: ø4
ø5/32"
C1
4A
2B
20.6
44.1
4A
X
One-touch fitting
[X: External pilot port]
Applicable tube O.D.: ø4
ø5/32"
D side
(5.3)
32
SI Unit
9.5
(4.9)
4 x ø5.3
(For mounting)
B
(L4)
L3
L5
A
U side
3/5
2 x M12
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
E
One-touch fitting
[1(P), 3/5(E) port] Note 1)
Applicable tube O.D.: ø10
ø3/8"
C2
30.6
25.2
11.9
9.2
20.5
B
Manual override
4(A) port side: Orange
2(B) port side: Green
35
68.5
102.9
109.4
A
5.5
A
A
Silencer
10.7
B
A
53.4
29.6 12.2
A
PWRCOM
B
115.5
97.5
B
5.4
B
A
B
A
B
8
L2
5
(Rail mounting pitch: 12.5)
L1
12
84.3
86.5
Interface regulator
SV2000-:-00
3
B
B
A
A
2
B
n: Stations
4
148
160.5 185.5
137.5 150
175
118
134
150
15
13.5 18
80
96
112
5
6
7
8
9
10
11
12
13
14
15
16
198
187.5
166
16
128
210.5
200
182
14.5
144
223
212.5
198
12.5
160
248
237.5
214
17
176
260.5
250
230
15.5
192
273
262.5
246
13.5
208
285.5
275
262
12
224
310.5
300
278
16.5
240
323
312.5
294
14.5
256
335.5
325
310
13
272
360.5
350
326
17.5
288
373
362.5
342
15.5
304
145.6
A
A
A
B
A
A
B
B
B
B
A
127.6
(7.5)
Interface regulator
SV2000-:-M1
Max. 21
59.6
46.5
1
1
63.5
52.5
V
3 P
E
P
2
5
V
3/5
E
42.5
4
2B
78.5
4A
2B
11.8
1
P
4A
2B
85
4A
L1
L2
L3
L4
L5
B
Individual EXH spacer
L: Dimensions
n
A
Individual SUP spacer
Note 1) When P, E port outlets are indicated on the U side or D side, the P, E ports on the
opposite side are plugged.
Note 2) External pilot port positions and silencer discharge port positions are the same as P, E
port outlet positions.
L
3/5
(Station 1)
E
(Station n)
Light/surge voltage suppressor
71
With Option
Gateway Decentralized System
Series SV3000
5 Port Solenoid Valve
Series SV3000
Tie-rod Base
Dimensions
With External Pilot Specification
(Pitch)
P = 20.5
21.3
48.6
11.8
18 11
2B
2
2B
2B
76.8
60.3
2B
B
1
35
P
1
E
P
C2
PE X
C1
4A
35 A
2B
B
1
4A
4A
2B
4 E
4A
2B
2B
2
P
35
1
PE X
C1
L3
L5
One-touch fitting
[PE: Pilot EXH port]
Applicable tube O.D.: ø6
ø1/4"
One-touch fitting
[X: External pilot port] Note 2)
Applicable tube O.D.: ø6
ø1/4"
(L4)
31.6
(5.1)
(5.3)
6.5
P
4 E
4A
4A
2 x M12
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
ø8, ø5/16"
ø10, ø3/8"
D side
U side
C2
4A
36
37.6
59.5
4A
35 A
One-touch fitting
[1(P), 3/5(E) port] Note 1)
Applicable tube O.D.: ø12
ø3/8"
E
36.1
13.5
11.6
23.5
9.5
35
68.5
10.1
5
Manual override
4(A) port side: Orange
2(B) port side: Green
4 x ø5.3
5.5
A
8
PWR COM
A
B
A
A
A
B
A
A
46.9
29.6 14.3
B
B
B
B
B
128.8
115.8
83.8
SI Unit
Silencer
L2
5
(Rail mounting pitch: 12.5)
L1
98.7
105.7
60.9
2
2B
5
3
P
1
1
P
A
A
(10)
B
B
B
B
A
A
A
A
157.9
A
139.9
B
B
B
A
VQC
B
14.7
Max. 21
75
E
Interface regulator
SV3000-:-00
SY
S0700
L: Dimensions
n: Stations
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
160.5
150
135.1
12.5
97
185.5
175
155.6
15
117.5
210.5
200
176.1
17
138
223
212.5
196.6
13
158.5
248
237.5
217.1
15.5
179
273
262.5
237.6
17.5
199.5
285.5
275
258.1
13.5
220
310.5
300
278.6
16
240.5
323
312.5
299.1
12
261
348
337.5
319.6
14
281.5
373
362.5
340.1
16.5
302
385.5
375
360.6
12.5
322.5
410.5
400
381.1
14.5
343
435.5
425
401.6
17
363.5
448
437.5
422.1
13
384
SV
L1
L2
L3
L4
L5
85.4
4 E 3/5
4A
101.2
2B
1
Interface regulator
SV3000-:-M1
Note 1) When P, E port outlets are indicated on the U side or D side, the P, E ports on the
opposite side are plugged.
Note 2) External pilot port positions and silencer discharge port positions are the same as P, E
port outlet positions.
n
1
4A
82.7
63.8
12
2B
B
1
Individual SUP spacer
Individual EXH spacer
L
P
4A
3/5 A
58.4
(Station 1)
E
(Station n)
Light/surge voltage suppressor
Gateway Decentralized System
With Option
86
Series SV4000
Series SV4000
Tie-rod Base
Dimensions
P = 24 24
With External Pilot Specification
48.6
11.8
20
11
2 B
2 B
4 E
3/5
2 P
74.8
58.3
2 B
4 A
4 A
40.4
63.9
4 A
1
3 A
E
1 B
P
4 A
4 A
4 A
2 B
2 B
4 A
3/5
4 E
1
2 P
35.8
2 B
1 B
P
4 A
3 A
35
E
14.5
13.7
25
C2
2 B
2 B
C2
PE X
One-touch fitting
[1(P), 3/5(E) port] Note 1)
Applicable tube O.D.: ø12
ø3/8"
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø8, ø5/16"
ø10, ø3/8"
ø12
PE X
C1
C1
2 x M12
Rc3/8
[1(P), 3(E) port]
Rc1/4, 3/8
[4(A), 2(B) port]
One-touch fitting
[PE: Pilot EXH port]
Applicable tube O.D.: ø6
ø1/4"
One-touch fitting
[X: External pilot port] Note 2)
Applicable tube O.D.: ø6
ø1/4"
D side
(L4)
U side
L3
L5
B
5.5
35
A
B
A
PWR COM
A
A
B
98.2
56.3
29.6 17.5
A
75
B
A
9.5
B
164.7
148.2
B
A
8
Manual override
4(A) port side: Orange
2(B) port side: Green
Silencer
68.5
81.7
13.3
[For Rc1/4, 3/8]
(5.4)
30.1
B
4 x ø6.2
SI Unit
L2
With Option
5
1
P
4 A
4 A
2 B
2 B
4 E
A
2 P
5
2 B
1
3 P
3/5
63
1
1
(Station 1)
E
(Station n)
Light/surge voltage suppressor
105.5
58.5
3/5 A
E
L1
88.5
107.5
114.5
(Rail mounting pitch: 12.5)
Individual SUP spacer
1
Interface regulator
SV4000-:-M1
1
Interface regulator
SV4000-:-00
(10)
14.7
16.2
Max.20
79.4
85.5
61.8
Individual EXH spacer
87
A
A
A
A
B
B
B
A
A
B
A
A
172.9
202.9
B
L1
L2
L3
L4
L5
B
n
B
L: Dimensions
L
B
Note 1) When P, E port outlets are indicated on the U side or D side, the P, E ports on the
opposite side are plugged.
Note 2) External pilot port positions and silencer discharge port positions are the same as P, E
port outlet positions.
n: Stations
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
173
162.5
145.6
13.5
109
198
187.5
169.6
14
133
223
212.5
193.6
14.5
157
248
237.5
217.6
15
181
273
262.5
241.6
15.5
205
298
287.5
265.6
16
229
323
312.5
289.6
16.5
253
348
337.5
313.6
17
277
373
362.5
337.6
17.5
301
385.5
375
361.6
12
325
410.5
400
385.6
12.5
349
435.5
425
409.6
13
373
460.5
450
433.6
13.5
397
485.5
475
457.6
14
421
510.5
500
481.6
14.5
445
Series EX500
Specific Product Precautions 1
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to “Handling Precautions for SMC
Products” and the Operation Manual on the SMC website, http://www.smcworld.com
Design / Selection
Warning
Mounting
Caution
1. Do not use beyond the specification range.
Using beyond the specification range can cause a fire, malfunction, or damage to the system.
Check the specifications before operation.
2. When using for an interlock circuit:
• Provide a multiple interlock system which is operated by another system (such as mechanical protection function).
• Perform an inspection to confirm that it is working
properly.
4. When lifting a large size valve manifold, take care to
avoid causing stress to the valve connection joint.
The connection joint of the product may be damaged.
Because the product may be heavy, carrying and installation
should be performed by more than one operator to avoid
strain or injury.
5. When placing a manifold, mount it on a flat surface.
Torsion in the whole manifold can lead to trouble such as air
leakage or contact failure.
Otherwise, this may cause possible injuries due to malfunction.
Wiring
Caution
1. When applicable to UL, use a Class 2 power supply
unit conforming to UL1310 for direct current power
supply.
2. Use within the specified voltage range.
Using beyond the specified voltage range is likely to cause the
product to be damaged or to malfunction.
Caution
1. Provide the grounding to maintain the safety of the
product and to improve the noise immunity.
Provide a specific grounding as close to the product as possible to minimize the distance to grounding.
3. Do not install in places where it can be used as a
foothold.
2. Avoid repeatedly bending or stretching the cable
and applying a heavy object or force to it.
Applying any excessive load such as stepping on the product
by mistake or placing a foot on it, will cause it to break.
Wiring applying repeated bending and tensile stress to the
cable can break the circuit.
4. Keep the surrounding space free for maintenance.
When designing a system, take into consideration the amount
of free space needed for performing maintenance.
5. Do not remove the name plate.
Improper maintenance or incorrect use of Operation Manual
can cause equipment failure or malfunction. Also, there is a
risk of losing conformity with safety standards.
Mounting
Caution
1. When removing from / attaching to the valve manifold,
• Do not apply excessive force to the Unit.
The connecting portions are firmly joined with seals.
3. Avoid miswiring.
If miswired, there is a danger of malfunction or damage to the
product.
4. Do not wire while energizing the product.
There is a danger of malfunction or damage to the product or
input/output device.
5. Avoid wiring the power line and high pressure line
in parallel.
Noise or surge produced by signal line resulting from the power line or high pressure line could cause a malfunction.
Wiring of the product or input/output device and the power line
or high pressure line should be separated from each other.
6. Check for the wiring insulation.
Defective insulation (contact with other circuits, improper insulation between terminals, etc.) may cause damage to the
product or input/output device due to excessive voltage or current.
• Take care not to get fingers caught.
Injury can result.
2. Do not drop, bump, or apply excessive impact.
Otherwise, this can cause damage, equipment failure or malfunction.
3. Observe the tightening torque range.
Tightening outside of the allowable torque range will likely
damage the screw.
IP65/IP67 cannot be guaranteed if the screws are not tightened to the specified torque.
88
Series EX500
Specific Product Precautions 2
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to “Handling Precautions for SMC
Products” and the Operation Manual on the SMC website, http://www.smcworld.com
Wiring
Caution
7. When the product is installed in machinery/equipment, provide adequate protection against noise by
using noise filters etc.
Noise in signal lines may cause a malfunction.
8. When connecting wires, prevent water, solvent or
oil from entering inside from the connecter section.
Otherwise, this can cause damage, equipment failure or malfunction.
9. Avoid wiring patterns in which excessive stress is
applied to the connector.
This may cause equipment failure or malfunction due to contact failure.
Operating Environment
Warning
1. Do not use in an atmosphere containing an inflammable gas or explosive gas.
Use in such an atmosphere is likely to cause a fire or explosion. This system is not explosion-proof.
Caution
1. Select the proper type of enclosure according to
the environment of operation.
IP65/67 is achieved when the following conditions are met.
1) Provide appropriate wiring between the products using
electrical wiring cables, communication connectors and cables with M12 connectors.
2) Suitable mounting of the product and valve manifold.
3) Be sure to mount a seal cap on any unused connectors.
If using in an environment that is exposed to water splashes,
please take measures such as using a cover.
When the enclosure is IP40, do not use in an operating environment or atmosphere where it may come in contact with
corrosive gas, chemical agents, seawater, water, or water vapor.
2. Provide adequate protection when operating in locations such as the following.
Failure to do so may cause a malfunction or equipment failure.
The effect of countermeasures should be checked in individual equipment and machine.
1) Where noise is generated by static electricity etc.
2) Where there is a strong electric field
3) Where there is a danger of exposure to radiation
4) When in close proximity to power supply lines
3. Do not use in an environment where oil and chemicals are used.
Operating in environments with coolants, cleaning solvents,
various oils or chemicals may cause adverse effects (damage,
malfunction) to the product even in a short period of time.
89
Operating Environment
Caution
4. Do not use in an environment where the product
could be exposed to corrosive gas or liquid.
This may damage the product and cause it to malfunction.
5. Do not use in locations with sources of surge generation.
Installation of the product in an area around the equipment
(electromagnetic lifters, high frequency induction furnaces,
welding machine, motors, etc.), which generates the large
surge voltage could cause to deteriorate an internal circuitry
element of the product or result in damage. Implement countermeasures against the surge from the generating source,
and avoid touching the lines with each other.
6. When directly driving a load (output device) which
generates surge voltage by relay, solenoid valves
or lamp, use a load that has an integrated surge absorption element.
When a surge generating load is directly driven, the product
may be damaged.
7. The product is CE marked, but not immune to lightning strikes. Take measures against lightning
strikes in your system.
8. Keep dust, wire scraps and other foreign matter
from entering inside the product.
This may cause equipment failure or malfunction.
9. Mount the product in such locations, where no vibration or shock is affected.
This may cause equipment failure or malfunction.
10. Do not use in places where there are cyclic temperature changes.
In case that the cyclic temperature is beyond normal temperature changes, the internal product is likely to be adversely affected.
11. Do not use in direct sunlight.
This may cause equipment failure or malfunction.
12. Observe the ambient temperature range.
This may cause a malfunction.
13. Do not use in places where there is radiated heat
around it.
Such places are likely to cause a malfunction.
Series EX500
Specific Product Precautions 3
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to “Handling Precautions for SMC
Products” and the Operation Manual on the SMC website, http://www.smcworld.com
Adjustment / Operation
Warning
1. Do not perform operation or setting with wet hands.
There is a risk of electrical shock.
<Web server function>
2. The valve operation test is a function which forcibly
changes the signal status Please check safety of
the ambient environment and the device before
using this function.
This may cause injuries or equipment damage.
3. If the communication line and PC are shut down
during a valve operation test, the valve output status will be held (It remains in the output status before the communication line and/or PC was shut
down). Please check safety of the ambient environment and the device when performing this function.
This may cause injuries or equipment damage.
Caution
1. Use a watchmaker’s screwdriver with thin blade for
the setting switch.
When setting the switch, do not touch other unrelated parts.
This may cause parts damage or malfunction due to a short circuit.
2. Provide adequate setting for the operating conditions.
Failure to do so could result in malfunction.
Refer to the Operation Manual for the setting switch.
Maintenance
Warning
1. Do not disassemble, modify (including circuit board
replacement) or repair this product.
Such actions are likely to cause injuries or equipment failure.
2. When an inspection is performed,
• Turn off the power supply.
• Stop the air supply, exhaust the residual pressure
in piping and verify that the air is released before
performing maintenance work.
Unexpected malfunction of system components and injury
can result.
Caution
1. When removing from / attaching to the valve manifold,
• Do not apply excessive force to the Unit.
The connecting portions are firmly joined with seals.
• Take care not to get fingers caught.
Injury can result.
2. Perform periodic inspection.
Unexpected malfunction in the system composition devices is
likely to occur due to malfunction of machinery or equipment.
3. After maintenance, make sure to perform an appropriate functionality inspection.
In cases of abnormality such as faulty operation, stop operation. Unexpected malfunction in the system composition
devices is likely to occur.
3. For details on programming and address setting,
refer to the manual from the PLC manufacturer.
4. Do not use benzine and thinner for cleaning the
product.
The content of programming related to protocol is designed by
the manufacturer of the PLC used.
Damage to the surface or erasure of the display can result.
Wipe off any stains with a soft cloth.
If the stain is persistent, wipe off with a cloth soaked in a dilute
solution of neutral detergent and wring out tightly, and then
finish with a dry cloth.
Other
Caution
1. Refer to the catalog of each series for Common
Precautions and Specific Product Precautions on
valve manifolds.
Trademark
DeviceNet™ is a trademark of ODVA.
EtherNet/IP™ is a trademark of ODVA.
90
Safety Instructions
These safety instructions are intended to prevent hazardous situations and/or
equipment damage. These instructions indicate the level of potential hazard with
the labels of “Caution,” “Warning” or “Danger.” They are all important notes for
safety and must be followed in addition to International Standards (ISO/IEC)
1),
and other safety regulations.
Caution indicates a hazard with a low level of risk which,
Caution:
if not avoided, could result in minor or moderate injury.
Warning:
Warning indicates a hazard with a medium level of risk which,
if not avoided, could result in death or serious injury.
Danger :
Danger indicates a hazard with a high level of risk which,
1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
ISO 4413: Hydraulic fluid power – General rules relating to systems.
IEC 60204-1: Safety of machinery – Electrical equipment of machines.
(Part 1: General requirements)
ISO 10218-1: Manipulating industrial robots – Safety.
etc.
if not avoided, will result in death or serious injury.
Caution
Warning
1. The compatibility of the product is the responsibility of the
person who designs the equipment or decides its
specifications.
Since the product specified here is used under various operating conditions,
its compatibility with specific equipment must be decided by the person who
designs the equipment or decides its specifications based on necessary
analysis and test results. The expected performance and safety assurance
of the equipment will be the responsibility of the person who has determined
its compatibility with the product. This person should also continuously
review all specifications of the product referring to its latest catalog
information, with a view to giving due consideration to any possibility of
equipment failure when configuring the equipment.
2. Only personnel with appropriate training should operate
machinery and equipment.
The product specified here may become unsafe if handled incorrectly. The
assembly, operation and maintenance of machines or equipment including
our products must be performed by an operator who is appropriately trained
and experienced.
3. Do not service or attempt to remove product and machinery/
equipment until safety is confirmed.
1. The inspection and maintenance of machinery/equipment should only be
performed after measures to prevent falling or runaway of the driven
objects have been confirmed.
2. When the product is to be removed, confirm that the safety measures as
mentioned above are implemented and the power from any appropriate
source is cut, and read and understand the specific product precautions
of all relevant products carefully.
3. Before machinery/equipment is restarted, take measures to prevent
unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of
safety measures if the product is to be used in any of the
following conditions.
1. Conditions and environments outside of the given specifications, or use
outdoors or in a place exposed to direct sunlight.
2. Installation on equipment in conjunction with atomic energy, railways, air
navigation, space, shipping, vehicles, military, medical treatment,
combustion and recreation, or equipment in contact with food and
beverages, emergency stop circuits, clutch and brake circuits in press
applications, safety equipment or other applications unsuitable for the
standard specifications described in the product catalog.
3. An application which could have negative effects on people, property, or
animals requiring special safety analysis.
4. Use in an interlock circuit, which requires the provision of double interlock
for possible failure by using a mechanical protective function, and
periodical checks to confirm proper operation.
1. The product is provided for use in manufacturing industries.
The product herein described is basically provided for peaceful use in
manufacturing industries.
If considering using the product in other industries, consult SMC beforehand
and exchange specifications or a contract if necessary.
If anything is unclear, contact your nearest sales branch.
Limited warranty and Disclaimer/
Compliance Requirements
The product used is subject to the following “Limited warranty and Disclaimer” and
“Compliance Requirements”.
Read and accept them before using the product.
Limited warranty and Disclaimer
1. The warranty period of the product is 1 year in service or 1.5 years after
the product is delivered, whichever is first.
2)
Also, the product may have specified durability, running distance or
replacement parts. Please consult your nearest sales branch.
2. For any failure or damage reported within the warranty period which is clearly our
responsibility, a replacement product or necessary parts will be provided.
This limited warranty applies only to our product independently, and not to any
other damage incurred due to the failure of the product.
3. Prior to using SMC products, please read and understand the warranty terms
and disclaimers noted in the specified catalog for the particular products.
2) Vacuum pads are excluded from this 1 year warranty.
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
Also, even within the warranty period, the wear of a product due to the use of the vacuum pad
or failure due to the deterioration of rubber material are not covered by the limited warranty.
Compliance Requirements
1. The use of SMC products with production equipment for the manufacture of
weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
2. The exports of SMC products or technology from one country to another are
governed by the relevant security laws and regulations of the countries involved
in the transaction. Prior to the shipment of a SMC product to another country,
assure that all local rules governing that export are known and followed.
Caution
SMC products are not intended for use as instruments for legal
metrology.
Measurement instruments that SMC manufactures or sells have not been
qualified by type approval tests relevant to the metrology (measurement) laws
of each country. Therefore, SMC products cannot be used for business or
certification ordained by the metrology (measurement) laws of each country.
Safety Instructions Be sure to read the “Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” before use.
Akihabara UDX 15F,
4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN
Phone: 03-5207-8249 Fax: 03-5298-5362
http://www.smcworld.com
© 2015 SMC Corporation All Rights Reserved
Specifications are subject to change without prior notice
and any obligation on the part of the manufacturer.
D-G
1st printing TZ printing TZ 11130SZ Printed in Japan.
Open as PDF
Similar pages