TM
Intelligent Central Systems
iCentral 10.2 Premium Video Intercom System
Installation & Operation Manual
REV2
www.icentralsystems.com.au
Sales, Service, Spares consumer enquiries
1300 050 333
iCentral Trade & Dealer Enquiries
Head Office
Ness Corporation Pty Ltd
ABN 28 069 984 372
Ph +61 2 8825 9222 Fax +61 2 9674 2520
ness@ness.com.au
www.ness.com.au
Copyright Notice
All rights reserved. No part of this publication may be reproduced, transmitted or stored in a retrieval system in any form or by any means,
electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Ness.
Ness reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing
product development and improvement.
© 2012 Ness Corporation ABN 28 069 984 372
Contents
Features / Specifications / Cable Specifications . . . . . . . . . . . . . . . . . . . . 4
Room Station Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Monitor Rear Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Monitor Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
System Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Connection Diagram 1 Door Station / 1 Room Station . . . . . . . . . . . . . . . 9
Connection Diagram 2 Door Stations / 1 Room Station . . . . . . . . . . . . . 10
Connection Diagram 2 Door Stations / 2 Room Stations . . . . . . . . . . . . 11
Switch Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Room Station Installation Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Door Station Installation Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-19
Features
Door Station
■■
■■
■■
■■
■■
■■
■■
■■
Zinc Alloy, surface mount
1/4 inch colour CCD camera
Resolution: 420TV Lines
Waterproof Vandal Resistant alloy housing
Built-in automatic 3 x LED lighting for night vision / Minimum illumination 1.0 lux
68 degree wide angle field of view
Compatible with Four Plus & 10.2 intercom systems
Part No. 100-958
■■
■■
■■
■■
■■
■■
■■
■■
■■
■■
■■
■■
■■
Slimline surface mounted Monitor/Room Station
10 inch colour LCD display
Touch sensitive glass buttons
Supports up to two video Door Stations and up to two video Room Stations
Make intercom calls between two Room Stations
Transfer door calls between Room Stations
Monitor up to two optional CCTV cameras or other audio/video inputs
Do Not Disturb function
Electric door lock release from Room Stations
Adjustable Colour/Contrast/Brightness/Ring Volume
Choice of 12 door bell chimes
Master/Slave selectable
Part No. 100-974
Room Station
Specifications
Room Station Display Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.2” TFT
Horizontal Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 420TVL
Input Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.8VDC
Video Channel Qty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Room Stations Supported Qty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5W ~ 16W
Wiring Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 core screened cable + RG59 coax*
Operating Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -10°C ~ 50°C
Room Station Dimensions (W x H x D). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334 x 210 x 25mm
Door Station Dimensions (W x H x D). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 x 173 x 25mm
In some installations the 100-958 Video Door Station may have audio feedback when used with a weathershield.
A simple modification to the microphone gain is available - please ask when ordering.
Cable Specifications
*Minimum wiring Requirements between Door and Room Stations
Up to 15m distance
Over 15m distance
4 core screened cable for
PWR, GND, AD and VD.
4 core screened cable for PWR & AD (only 1 pair required)
RG59 coax for GND & VD.
Maximum cable distance.
Master Station to Slave Station: 60m
Door Station/s to Master Station: 80m
Recommended cable
100-960 4 Core Screened cable 100m reel
100-353 RG59 Coax cable 100m reel
NOTE - 4 Core Screened cable
Connect outer screen to GND at the
master station end only.
4
Room Station Description
5
1
6
2
7
3
9
4
8
1
Monitor button
2
Answer / Call / Transfer / Intercommunication button
3
Door release button
4
Off / Save button
5
Adjust Left/Right buttons
6
Menu: Brightness/Contrast/Colour button
7
Chime Select button
8
Microphone
9
10” Colour Screen
5
Room Station Rear Description
DESCRIPTIONS OF MONITOR-REAR: (10.2 inch TFT Power voltage:DC 13.8V)
12
Speaker
13
Door Station 1 connection
14
Door Station 2 connection
15
Slave Room Station connection
16
Optional Audio/Video Input 1 connection
17
Optional Audio/Video Input 2 connection
18
Master/Slave selector dipswitches
DIMENSION: 19
20
Door 1 lock release output, 12VDC
Power input 13.8VDC
6
6
Room Station Connections
DESCRIPTIONS OF MONITOR CONNECTIONS:
Slave Station
(10.2 inch TFF, Power voltage:DC 13.8V)
Power Input
13.8VDC
VD: Video Input
AD: Audio Input
GND: Ground
DATA: Data
Door Lock Output
13.8VDC
A/V Input 1
VD3: Video Input
PWR3: 13.8VDC Output
GND: Ground
AD3: Audio Input
Door Station 1
PWR1: Power
GND: Ground
AD1: Audio
VD1: Video
A/V Input 2
VD4: Video Input
PWR4: 13.8VDC Output
GND: Ground
AD4: Audio Input
Door Station 2
PWR2: Power
GND: Ground
AD2: Audio
VD2: Video
9
7
System Schematic
100-958 Door Station (max. 2)
100-974 Room Station (max. 2)
13.8VDC supply
Selected as
Master
Optional
electric locks
Optional CCTV cameras,
TV tuner or other A/V
inputs. Max 2.
13.8VDC supply
Selected as
Slave
8
Connection Diagram 1 Door Station / 1 Room Station
Door Lock Connection, Method 1
Notes
1. The Room Station provides power for the electric door strike.
2. One extra pair of wires is required between the door and the Room Station.
This method eliminates the need to provide a dedicated power supply for the electric
door strike.
100-974
10.2 Room Station
100-958
Door Station
Master Setting
Both switches ON
PW
GND
AD
VD
GND
Lock1
PWR1
GND
AD1
VD1
Key1
Key2
VD3
PWR3
GND
AD3
PWR2
GND
AD2
VD2
Not
used
840-003
Power Supply
13.8VDC
13.8V13.8V+
VD
AD
GND
Data
VD4
PWR4
GND
AD4
12VDC Electric
Door Strike
Door Lock Connection, Method 2
Notes
1. The electric door strike is unlocked by a pair of dry relay contacts at the Door Station.
2. A dedicated power supply is required for the electric door strike.
3. If the door strike power supply is located near the front door then only 4 wires are
required between the door and the Room Station.
4. This method provides lower security as the door strike can be operated by shortcircuiting the KEY1 & KEY2 wires at the back of the door station.
100-974
10.2 Room Station
100-958
Door Station
VD
AD
GND
Data
Master Setting
Both switches ON
PW
GND
AD
VD
PWR1
GND
AD1
VD1
Key1
Key2
PWR2
GND
AD2
VD2
13.8V13.8V+
Power Supply
840-003
GND
Lock1
VD3
PWR3
GND
AD3
VD4
PWR4
GND
AD4
Up to 15m cable length use 4 core screened cable for audio,
video and power. Over 15m cable length, use RG59 coax cable
for VD and GND.
Door Strike
Power Supply
840-003 or equivalent
Max. cable distance: Master-Slave: 60m / Door-Master: 80m
12VDC Electric
Door Strike
See page 4 for further detail.
9
Connection Diagram
2 Door Stations / 1 Room Station
100-974
10.2 Room Station
PW
GND
AD
VD
13.8V13.8V+
GND
Lock1
PWR1
GND
AD1
VD1
Key1
Key2
100-958
Door Station 1
VD
AD
GND
Data
PW
GND
AD
VD
PWR2
GND
AD2
VD2
VD3
PWR3
GND
AD3
VD4
PWR4
GND
AD4
24/020 FIG8 Cable
Master Setting
Both switches ON
Key1
Key2
100-958
Door Station 2
840-003
Power Supply
13.8VDC
12VDC Electric
Door Strike
Door Strike
Power Supply
840-003 or equivalent
12VDC Electric
Door Strike
Door Strike
Power Supply
840-003 or equivalent
Up to 15m cable length use 4 core screened cable for audio,
video and power. Over 15m cable length, use RG59 coax cable
for VD and GND.
Max. cable distance: Master-Slave: 60m / Door-Master: 80m
See page 4 for further detail.
10
Connection Diagram
2 Door Stations / 2 Room Stations
100-974
10.2 Room Station 1
selected as master
Master Setting
Both switches ON
PW
GND
AD
VD
VD
AD
GND
Data
PWR1
GND
AD1
VD1
Key1
Key2
PW
GND
AD
VD
100-958
Door Station 1
PWR2
GND
AD2
VD2
13.8V13.8V+
GND
Lock1
VD3
PWR3
GND
AD3
VD4
PWR4
GND
AD4
Key1
Key2
100-958
Door Station 2
100-974
10.2 Room Station 2
selected as Slave
Door Strike
Power Supply
840-003 or equivalent
12VDC Electric
Door Strike
Slave Setting
Both switches OFF
Door Strike
Power Supply
VD
AD
GND
Data
PWR1
GND
AD1
VD1
840-003 or equivalent
PWR2
GND
AD2
VD2
13.8V13.8V+
GND
Lock1
VD3
PWR3
GND
AD3
24/020 FIG8 Cable
12VDC Electric
Door Strike
VD4
PWR4
GND
AD4
840-003
Power Supply
13.8VDC
Note:
A single 840-003 13.8VDC power supply can be used to
power both room stations.
If the distance between room stations is over 30m install
one power supply at each room station.
Up to 15m cable length use 4 core screened cable for audio,
video and power. Over 15m cable length, use RG59 coax cable
for VD and GND.
Max. cable distance: Master-Slave: 60m / Door-Master: 80m
See page 4 for further detail.
11
Switch Settings
When connecting two room stations to the system, set the dipswitches on the rear
panel of each station as follows.
Switch 1. Enables video load impedance
Switch 2. Master/Slave setup
Please disconnect power to each station before changing switch settings.
Master station
Or single station
Set both switches ON
Slave station
Set both switches OFF
ON
ON
OFF
OFF
12
MONITOR INSTALLATION GUIDE:
Installation Instructions:
Room Station Installation Guide


Please select relevant wire diagram for your chosen
Make sure you use correct cable for system required
Single Monitor Installations:
 Select correct height of indoor monitor , usua
1. Use the recommended cable between all stations.
NSTALLATION GUIDE:
2. Determine the correct height for the Room Station/s. Typical installation height is
150~160CM(See below Figure 1)
between 150-160cm. See figure 1.
structions:
elevant wire diagram for your chosen system
u use correct cable for system
required.
3. Run
the cable
tallations:
t height of indoor
through the bracket and mount
the After
bracket
to the wall
screws.
determine
theusing
monitor
bracket position and
4. Terminate the cable at the monitor following the relevant
wiring
diagram
in this
locating
screws
in bracket.
manual.
monitor , usually installation height is between
(See below Figure 1)5.
 2.Finally, install the indoor monitor on the wall as belo
Fit the Room Station on the bracket. See Figure
ne the monitor bracket position and run cable through the bracket, fix
s in bracket.
the indoor monitor on the wall as below Figure 2.
Fig. 1
Fig. 2
19
19
13
Door Station Installation Guide
DOOR BELL INSTALLATION GUIDE:
1. Please take care to select the most suitable position for the Door Station.
Doorbell
Installation:
2.
Consider
all factors which may affect audio and video performance such as likely
sun position in daytime, shadows, blindspots, avoid backlighting, and the likely
 Please take some time to select the most suitable position for doorbell.
weather impact.
 Please consider the factors of day time, night time and likely weather condition impact.
3.Direct
on the
the camera
cameraand
anddirect
expose
to rain
should
be avoided.
 Direct Sunlight
sunlight on
contact
with
rain should
be avoided.
 Determine the
Camera
Position:
we height
recommend
thepremises.
door bell Typical
and theinstallation
camera should
4.Determine
best Door
Station
for your
heightbe at
the
same
height
(
Average
Height
from
1.5
to
1.6
meters
)
is 150 - 160cm.
20
14
Operating Instructions
15
Operating Instructions
How to answer the Door Station and release the door lock
When a visitor presses the call button at the front door/s the room station/s will chime and the
monitor will display the video from the front door which called.
Press
Answer
Intercom
to answer. You have 60 seconds to talk with the visitor
Press
to hang up.
Press
to release the door lock (if fitted).
If the system has two door stations, the door lock which made the call is released.
How to Transfer a call (If two room stations are installed)
To transfer a call from the door station to the other room station.
Answer
Press the Intercom button again. The call will be transferred to the other room station. Your
room station will hang up once the call has been transferred. Conversation time is 60
seconds.
16
Operating Instructions
How To Monitor Audio & Video Inputs
Your 10.2 Intercom System has four Audio/Video inputs that can be viewed at any room
station.
Inputs 1 & 2 provide audio and video signals from Door1 and Door2.
Inputs 3 & 4 provide audio and video signals from two optional A/V sources such as CCTV
cameras, TV tuners, MP3 players and many other types of devices for surveillance or
entertainment.
Press
Monitor
to display video from Door1. The image will display for 30 seconds.
Press
Monitor
again to display video from Door2. The image will display for 30 seconds.
Press
Monitor
again to display video and audio from A/V Input 1.
Press
Monitor
again to display video and audio from A/V Input 2.
Note 1. The image and audio (if connected) from A/V1 & A/V2 will remain on until another
input is activated or
is pressed.
Note 2. If a call is made from a door station while an A/V input is being monitored, the display
will switch to allow the call from the front door. When the call is completed the display will
return to the previous A/V input.
17
Operating Instructions
How to Make an intercom call between two room stations
In standby mode press
Answer
Intercom
at your room station.
The other room station will chime.
Press
Answer
Intercom
on the other room station to take the call.
How to Adjust Brightness/Contrast/Colour
At any time with an image on the display:
RGB
Press Video/set The monitor will display the “Brightness” level.
Use the < or > button to adjust the image brightness.
RGB
Press Video/set again. The monitor will display “Contrast” level.
Use the < or > button to adjust the image contrast.
RGB
Press Video/set to save the settings and return to the main menu.
Press
to exit.
18
Operating Instructions
How to Choose the call Chime Tune
To choose one of the 12 available chime tunes.
Have one person press the call button on the door station.
At a room station press Chime/set to change the tune.
Press repeatedly to play each tune in turn.
Press Off/Save to save the selected chime tune.
How to Adjust Room Station Volume
During a front door call or when listening to an optional audio source from A/V1 or A/V2:
Use the < or > buttons to adjust speaker volume at the room station.
How to use the “Do Not Disturb” Function
The “Do Not Disturb” function can be activated when you don’t want to be disturbed by calls from the front door or another room station.
To activate Do Not Disturb mode
In standby mode press
Chime/set
for 2 seconds. The button will light up red.
In Do Not Disturb mode you will still see video from a front door call and you can answer the call, but the chime will be silent. Intercom calls from another room station will be ignored.
To Cancel Do Not Disturb mode
Press
Chime/set
for 2 seconds. The red lit button will turn off.
19
Open as PDF