Gasket Locations
CABLE SHROUD
SUPPLIED ONLY
ON 435VFS15.
ENSURE THIS IS
SECURED AFTER
435VFS15 CABLE
CONNECTIONS.
BACK OF 415VF OR
435VFS15 SHOWN
WITHOUT GASKET.
NOTE: If using 435VFSM mounting
Caravan Inlet & Outlets
BLACK
RUBBER
GASKET
INSERTED
IN PLACE.
Instruction Manual
415VF Series - Flush socket outlet with weatherproof Flap IP34
435VFS15
- Flush inlet with weatherproof Flap IP34
435VFSM
- Mounting flange to suit 415VF and 435VFS15
FOAM GASKET
MOUNTING FLANGE
Supplied separate.
Mounting Flange
may be required
when mounting
415VF or 435VFS15
on to narrow walls.
(See notes on back
page for Gasket
Locations.)
MOUNTING FLANGE
flange, the black rubber gasket
supplied with the 435VFSM
mounting flange must be inserted
into the back recess of the 415VF or
435VFS15 product as shown. The
foam gasket supplied with 415VF
or 435VFS15 product should be
mounted on wall surface regardless
STEP 1:
Mark and cut out hole in wall
where 415VF, 435VFS15 or
435VFSM is to be located (use
foam gasket as a template).
STEP 2:
Fix foam gasket over hole.
STEP 3:
If required place 435VFSM
Mounting Flange on gasket.
STEP 4:
Connect cables to socket and
screw fix socket to product housing
(fix shroud for 435VFS15)and screw
fix product to wall.
Recommended screws see NOTE below
if mounting flange is used.
NOTE: Silicon may be required on
some surfaces to achieve IP34 rating.
FOAM GASKET
Clipsal Australia Pty Ltd reserves the right to change specifications or
designs described in this manual without notice and without obligation.
Product of Clipsal Australia Pty Ltd
ABN 27 007 873 529
12 Park Terrace, Bowden, South Australia 5007
Telephone (08) 8269 0511
Facsimile
(08) 8340 1724
Internet
clipsal.com
E-Mail
plugin@clipsal.com.au
F1832
NOTE: Recommended Clipsal mounting screws
CLIPADV/8782
• 357P30 6 Gauge x 30mm Pan head self drilling screw
or when used with a 435VFSM mounting spacer
• 357P50 6 Gauge x 50mm Pan head self drilling screw
Wiring Instructions - 435VFS15
Wiring Instructions - 415VF Series
CORD CLAMP
CORD CLAMP
8.5
Recommended for use with
0.75mm2 to 1.5mm2 PVC
insulated ordinary duty 3 core
circular flexible cords.
Recommended for use with 0.75mm2
to 1.5mm2 PVC insulated ordinary
duty 3 core circular flexible cords.
WIRING INSTRUCTIONS
Note: All wires are clamped between the moving nut and the fixed contact.
DO NOT wrap wires under head of screw.
WIRING INSTRUCTIONS
1.
Strip insulation (as illustrated) and twist bare conductor strands.
Note: All wires are clamped between the moving nut and the fixed contact.
DO NOT wrap wires under head of screw.
2.
Slide the connector cover over the flex.
1.
Strip insulation (as illustrated) and twist bare conductor strands.
3.
Connect the Earth wire (Green/Yellow or Green) to the terminal
marked ‘E’.
2.
Slide the plug cover over the flex.
4.
Connect the Active (Live) wire (Brown or Red) to the terminal marked ‘A’.
3.
Connect the Earth wire (Green/Yellow or Green) to the terminal marked ‘
5.
Connect the Neutral wire (Blue or Black) to the terminal marked ‘N’.
4.
Connect the Active (Live) wire (Brown or Red) to the terminal marked ‘L’.
6.
Place the Earth wire into the slot as illustrated and tighten cord clamp
around outer sheath of flexible cord.
5.
Connect the Neutral wire (Blue or Black) to the terminal marked ‘N’.
6.
Tighten cord clamp around outer sheath of flexible cord.
NOTE: 5mm of sheath minimum must be beyond the end of the
cord clamp.
NOTE: 5mm of sheath minimum must be beyond the end of the
cord clamp.
7.
Check the wires are in their correct position (as illustrated) and
the terminal screws are tight.
7.
Check the wires are in their correct position (as illustrated) and
the terminal screws are tight.
8.
Locate the outlet into position and ensure the fixing
screws are fully tightened.
8.
Locate the inlet into position and ensure the fixing
screws are fully tightened.
9.
Secure product to the wall.
9.
Secure product to the wall.
’.
Open as PDF