INVERTER-driven
Split-ductless and ducted Comfort Systems
M–Series Full–Line Catalog
www.mitsubishicomfort.com
Mitsubishi Electric Cooling and Heating Solutions
Mitsubishi Electric HVAC products, available in the
U.S. for thirty years, have provided exceptional,
personalized comfort control while being very
energy efficient.
Mitsubishi Electric’s INVERTER-driven compressor systems
use refrigerant lines to connect an outdoor unit to one or
more indoor air handlers. A home's or building's energy
efficiency increases when only the amount of cooling or
heating needed for the space where the unit is installed.
Advanced technologies are used to control the precise
temperature in each room and have the capability to condition
only the rooms in use.
Using a wireless remote or wall-mounted controller for each
space, Mitsubishi Electric systems allow a truly personal
level of comfort. Environmentally friendly refrigerant (R410A),
advanced filtration systems, and high efficiency ratings are
standard on all Mitsubishi Electric HVAC systems.
This synergy of smart design and cutting-edge environmental
technology delivers an end result of true eco-comfort for any
conditioned space.
2
Table of Contents
Mitsubishi Electric is dedicated to providing
environmentally responsible systems that
minimize the environment and our customer’s
carbon footprint.
MS/MSY Air Conditioner Specifications . . . . . . . . 10
MSZ Heat Pump Specifications . . . . . . . . . . . . . . 12
SEZ Heat Pump Specifications and Curves . . . . . 14
SLZ Heat Pump Specifications. . . . . . . . . . . . . . . 16
MXZ-B Outdoor Unit Specifications . . . . . . . . . . . . 21
MXZ-8B48 Outdoor Unit Specifications . . . . . . . . 23
MSZ/MFZ/SEZ/SLZ Indoor Unit Specifications . . . 24
Multi-Zone
System Overview and Applications . . . . . . . . . . . . 18
20,000 - 48,000 Btu/h
2:1, 3:1, 4:1, 8:1
Mitsubishi Elelectric's environmental commitment is
evidenced by the fact that up to 83% of our system
components are recyclable. More of our systems are
ENERGY STAR® certified and qualify for the federal tax
credit of up to $300. Local and state government and
utility companies may provide tax credits and rebate
opportunities for energy-efficient systems. See what's
available in your area by visiting www.dsireusa.org.
System Lineup . . . . . . . . . . . . . . . . . . . . . . . . . . . . 08
Single-Zone
How environmentally friendly are
Mitsubishi Electric HVAC systems?
9,000-36,000 Btu/h
System Overview and Technology . . . . . . . . . . . . . 04
Rating Conditions, Refrigerant Tubing . . . . . . . . . . 26
Line Lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
MXZ Port Adaptors. . . . . . . . . . . . . . . . . . . . . . . . . 28
DIAMONDBACK® Ball Valves . . . . . . . . . . . . . . . . . 29
DIAMONDBACK® Platform Stands . . . . . . . . . . . . 29
DIAMONDBACK® Linesets . . . . . . . . . . . . . . . . . . . 30
Filter Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
How many ENERGY STAR rated systems qualify
for the federal tax credit?
20
LINE-HIDE™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
systems are ENERGY STAR rated.
14 systems qualify for the federal tax credit.
Qualified systems include the following products: coolingonly, heat pump, H2i® Hyper-Heating INVERTER heat-pump,
2-to-1, and 3-to-1 multi-zone heat pump systems.
For details on tax credit requirements, visit
www.mitsubishicomfort.com/taxcredit, and for information
on available local rebate opportunities from state or utility
companies, visit www.dsireusa.org, which is a
U.S. Department of Energy information service.
3
Mitsubishi Electric System
Technologies: user-friendly zoned residential
personalized comfort solutions
Mitsubishi Electric indoor units are easy to install–practically anywhere:
• High on the wall to blend into a room without taking up window space
• In the ceiling or below the floor out of sight
• Low on the wall to be unobtrusive
Our systems are the perfect way to cool or heat any single room or multiple
rooms in homes or office.
Heat-pump systems feature auto mode, which automatically switches
between cooling and heating in response to changing needs. Our systems
are nearly silent; their fans deliver air quietly and continuously with only
a gentle "whoosh" for constant circulation and filtration. For this reason,
Mitsubishi Electric split-zoning systems have long been the choice for
thousands of homes, churches, schools, and libraries across the U.S.
and the world.
Technology Benefits of Mitsubishi Systems
Features
Benefits
INVERTER-driven
compressors
Maximizes energy savings by making sure only the energy needed
to cool or heat an area perfectly is used.
Easy installation
Installs quickly and easily, having no need for major construction
and remodeling.
COmplete Zone
control
ealizes maximum control and energy efficiency by cooling
R
and heating only those spaces in use.
advanced
microprocessor
technology
Creates a comfortable environment no matter what conditions are
outside with our advanced, self-monitoring controls.
Personal comfort
control
Offers comfort control of temperature, fan speed, and air direction
in the specific zone with dedicated controller.
washable, long-life
anti-allergen filters
Improves air quality and saves money by washing
rather than replacing the filter.
auto cool/heat
changeover
Switches automatically from cooling to heating
(MUZ/SUZ systems) if desired.
environmentally
friendly refrigerant
Uses R410A, an environmentally friendly refrigerant.
Energy Efficiency Recognized
Mitsubishi Electric split-zoning, cooling-only and heat pump systems are so energy efficient
that currently 20 systems of our INVERTER-driven systems are ENERGY STAR® rated. This
can mean big savings.
Add in the federal tax credit and local government and utility rebates, and you have an
opportunity to enjoy comfort at substantial savings.
Get the free app for your smart
phone at http://gettag.mobi
4
For details on qualifying systems, go to www.mitsubishicomfort.com/taxcredit,
or use your smart phone to scan the tag to the left and go to the page.
Visit www.dsireusa.org for information on available local rebate opportunities
from state or utility companies.
Innovative Variable-speed Compressor Technology
MUZ-FE H2i Heating Capacity
at Low Temperatures*
100%
73%
MUZ-FE09NA
MUZ-FE09NA
Single-Zone System Overview and Technology
Sophisticated electronic control systems detect any changes in room or zone temperature and—like a car’s cruise control—automatically adjust the speed of the outdoor units
INVERTER-driven compressor and electronic linear expansion valve (LEV) position for
precise capacity control. The INVERTER-driven compressor is unlike those found in other
systems which only start and stop repetitively. Special components within the INVERTER
compressor such as high density windings in the motor that increase the magnetic flux,
and artificial magnets in the rotor to reduce its weight, allowi it to operate at higher energy
efficiencies with better performance than ever before, while producing low sound levels
both during start-up and operation.
Heat and Lots of It
In addition to the already innovative
INVERTER-driven compressor, the
MSZ-FE high-efficiency systems
are also ENERGY STAR® rated and
tax credit qualified up to 26 SEER
delivering exceptional heating performance.
MUZ-FE12NA
MUZ-FE12NA
MUZ-FE18NA
UNITARY
*Includes correction for defrost
These systems provide heating down to -13˚ F outdoor
ambient and produce up to 100% heating capacity at 5˚
F MSZ-FE09/18; 92% capacity at 5˚ F for MSZ-FE12. Our
systems provide year–round comfort in extreme climates while
being extremely energy efficient. There usually is no need for
resistance electric or other supplemental, energy–consuming
devices with this performance.
i-see™ Sensor
(MSZ-FE09/12NA models only)
The i-see Sensor detects temperature variations in hardto-control ceiling and floor areas, and controls the airflow
up to a wide lateral angle for ultimate comfort (90˚ angle
in cooling mode).
By scanning the room and adjusting airflow based on
ambient temperature readings, MSZ-FE systems achieve
superior cooling/heating performance with extremely
efficient operation.
*Low Ambien t temper atu r e con dition s may r equ ir e base pan h eader (GE and F E 1:1 s y s tem s )
5
Superior Operation
Advanced Control Technology
Through Mitsubishi Electric’s advanced controls technology,
the indoor unit is powered by the outdoor unit. Three
polarity sensitive wires plus a ground conductor run from
the outdoor to the indoor unit, providing both power and
data communication. An advanced wireless remote
control is available for all ductless models. An optional
wired on-the-wall controller is available for wallmounted/floor-standing indoor units on INVERTER
systems (also requires MAC-397 If adapter).
Quiet Operation
System Control
Do you hear that? No? Mitsubishi Electric systems
operate at low sound levels; our indoor units produce
decibels barely at a whisper level.
Compare to other common sounds:
Mitsubishi Electric offers a comprehensive remote
controller that can adjust temperature, fan speed, and
more. Choose from four modes: COOL, HEAT, AUTO,
and DRY. The controller also has a 12-hour ON/OFF
timer for one-button control of your personal comfort.
Police siren 118 decibels
Circular saw 107 decibels
Vacuum cleaner 74 decibels
Whisper-tone voice
35 decibels
Library reading room 33 decibels
Our Indoor Units
19 - 34 decibels
(at low speed)
Did you hear that? We hope you did.
Our hot-start heat-pump technology provides warmth
from the beginning. The fan increases in speed as
the coil is warmed, reducing drafts so when you want
warm air, you get it.
whisper quiet
6
With easily accessible filters, little or no ductwork
to clean, and simple wiring between the indoor and
outdoor units, Mitsubishi Electric systems require
minimal maintenance, providing another level of
convenience.
Auto Changeover on Heat-Pump Systems
Warm Air, No Drafts
comfort
Easy to Maintain
(MUZ/SUZ outdoor units)
Our heat-pump systems sense whether a space needs
cooling or heating, and automatically switch modes as
needed to maintain a consistent temperature. You can
set it and forget it.
healthier air
set it and forget it
Total Comfort
Smart Set, featured on MSZ-GE-06
to GE-18 systems provides the option
to program multiple settings into one
quick-press feature, providing an
additional level of comfort control.
Additional Air Circulation
With the WIDE VANE or SWING mode, available on the MSY(Z)-FE18/
GE24/D30/36NA, there is an option for seven horizontal airflow directions
that provide 150˚ of lateral airflow for greater conditioned air circulation.
The Powerful mode (found on select
systems) is available to cool or heat
any desired space quickly by lowering
the set temperature in cooling mode or
raising the set temperature in heating
mode, both by 7˚ F. In POWERFUL
Mode, the fan speed increases for 15
minutes, then the system resumes all
standard operations.
150˚
Standard filter system
Multiple Filters for Cleaner,
Healthier Air
Mitsubishi Electric indoor units use a
sophisticated multi-part filter system to
remove contaminants such as allergens,
viruses, and bacteria from the air.
(used in MSY/MSZ-GE/FE18/D Models)
Front Panel
Hybrid Catechin
pre-filters
A hybrid catechin pre-filter absorbs odorcausing gases. The hybrid-coating process
makes the catechin filter washable and—if
properly maintained with regular cleaning—
remains effective for up to 10 years.
A Blue-enzyme anti-allergen filter reduces
germs, bacteria, and viruses, and helps
trap dust, pollens, mites, and other
particles. The filter uses an enzyme catalyst
to help break down the sulfur atom bonds
in allergen proteins, transforming them into
non-allergen proteins, and, effectively
cleaning the air. The filter should be
cleaned regularly to maintain efficiency.
The high-efficiency MSZ-FE09/12NA
indoor units incorporate the standard
Catechin filter plus two more filters for
triple filtration. The second filter, a Blueenzyme filter made of a fibrous material,
renders allergens harmless by using
enzymes. The third filter, a Platinum
Catalyst Deodorizing filter, has a ceramic
surface absorption element and uses
nanotechnology for high-power odor
absorption. Periodic cleaning, following the
recommended procedures, will maintain
filter effectiveness for up to two years.
This combination of filters provides
a complete air-purifying system
within the ultimate comfort solution.
Blue Enzyme
anti-allergen filter
enhanced filter system
(used in MSZ-FE09/12NA Models)
Front Panel
Hybrid Catechin
pre-filters
Platinum Catalyst
Deodorizing filter
Blue Enzyme
anti-allergen filter
7
Single-Zone System Overview and Technology
Programmable Comfort
System Lineup
RESIDENTIAL AND LIGHT COMMERCIAL system models and controllers
S IN GL E - R OO M , WALL -M OU NT E D A / C
(cooling only)
MS Y /MU Y
A i r C ond i t i oners
3,800 t o 34,600 Bt u/h
C ap aci t y Range
15.1 - 21 S EER
MS/MU
Air Co ndit io ne r s
9,500 t o 12, 000 B t u /h
Ca pa c it y Ra ng e
13 S E E R
• Provides cooling-only system
• Non-INVERTER rotary compressor
• Ideal for spaces such as
bedrooms, garages, out-buildings,
video monitoring
• Cooling-only system
• INVERTER-driven compressor
• WIDE VANE for a wider angle of airflow, 150˚ from
left to right (on GE24/D30/D36/FE18 models)
• Ideal for spaces such as bedrooms, garages, large open rooms and bonus rooms
SI N GLE- R OO M , WALL - M OU N T E D H E AT PUM P S
MSZ/MUZ
He a t P u m p s
3, 800 t o 33, 2 0 0 B t u /h
Ca pa c it y R a n g e
14.5 - 21 SEER
8.2 - 10 HSPF
(cooling and heating)
Up to 26 SEER!
• Uses INVERTER-driven compressor
• Provides cooling and heating in a wide range
of capacities
•Offers a WIDE VANE for a wider angle of airflow, 150˚ from
left to right (on GE24/D30/D36 models)
• Ideal for applications in bedrooms, home offices, living rooms, dining rooms, bonus rooms, basements, kitchens, guard houses and more
MS Z/MU Z- FE09/12/18N A
H i gh- Eff i ci ency H eat P ump s
2,800 t o 25,200 Bt u/h C ap aci t y Range
20.2 - 26 S EER
10 - 10.6 HSPF
•
•
•
•
•
INVERTER-driven compressor
Quiet operation as low as 19dB(A)
i-see™ Sensor technology (only on 09/12 units)
Enhanced filtration system (only on 09/12 units)
H2i® high-heat capabilities (see page 12 &13)
MSZ-FE09 is 100 percent at 5˚ F
MSZ-FE12 is 92 percent at 5˚ F
MSZ-FE18 is 100 percent at 5˚ F
S INGLE- ROOM , LOW WALL o r F LOO R -S TA ND I NG U NI T
MFZ
(For u se w ith MXZ- B
Out door Unit s only )
•
•
•
8
Provides cooling and heating in a wide range of capacities
Two outlet air vents:
- Upper vent for cooling or heating
- Bottom vent for heating only
Flush or recessed installation
New to our lineup is a Low Wall or Floor-Standing
model that can fit into those once difficult installations.
These units provide comfort in spaces such as
finished attics with knee walls, basements with
low ceilings, and glass-walled sunrooms.
These models provide conditioned air two vents,
and provide direct front-panel access to the filter for
easy cleaning. The MFZ can even be recessed in a
wall during installation provided proper clearances are
maintained. (Currently there is no 1:1 system with MFZ)
(for use with MXZ-B)
SI N GLE - R OO M , HO R IZ O N TAL -DUC T E D H E AT PUM P S
(cooling and heating)
If your customer is looking for discrete zoned comfort, then a short-run ducted unit
is the right solution. As a stand-alone system or connected to a MXZ multi-room
system, the SEZ ducted units provide energy efficiency, quiet operation, and a
compact design for quick, easy installation hidden either in the ceiling or beneath
the floor.
All of the 1:1 systems are ENERGY STAR certified, and two systems qualify for
the federal tax credit. These systems provide customers with an environmentally
friendly indoor unit with a similar installation and familiar style.
These SEZ indoor units also connect to MXZ multi-zone systems, providing a wide
array of installation options to best fit any application.
SI N GLE- R OO M , C E IL IN G - R E C E S S E D CAS S E T T E U NI T
SLZ/SUZ
Heat Pumps
The SLZ-KA ceiling-recessed units casette offer a wide
3,100 to 22,200 Btu/h air-flow pattern for better air distribution in a less obtrusive
Ca pa c it y R a n g e
15 - 16 SEER
9.6 HSPF
style. These indoor units can be used in 1:1 heat pump
and multi-zone systems providing more options to your
customers. Install SLZs in a hard ceiling (with a access panel for
servicing) or in a 2x2 extra space drop ceiling. With a built-in drainlift mechanism for condensate removal and a 4" ventilation-air intake
knockout option, and multiple options for the 1:1 systems, the SLZ handles a variety of installation needs.
Two of the three 1:1 systems are ENERGY STAR qualified.
W IR E L E S S a nd W I R E D R E M O T E CONT R OLL E R S
Wireless remote controller
for wall-mounted and
floor-standing indoor units
Operation
Select
(Heat, Cool,
Auto, Dry)
Fan Speed
Timer
Vane
Control
HR./MIN.
(Time Set)
Econo
Cool
Set Temperature
PAR-21MAA
On/Off
Timer Menu
Fan Speed
Mode
Filter
Test Run
Set Time
Check
Airflow Up/Down
Timer On/Off
Louver
Smart Set
Button
Ventilation
Reset
Optional wired controller for the
SEZ, SLZ, MFZ and MSY/Z indoor units.
(Optional controller for wall-mounted is available:
and floor-standing indoor units.
Unit requires MAC-397 If adapter)
MHK1 WIRELESS REMOTE CONTROLLER
Exclusive for INVERTER-driven Mr. Slim® Systems*
TM
* SEZ and SLZ 1:1 systems with SUZ outdoor unit only
MR CH1
MIFH1
9
Single-Zone System Showcase
SEZ/SUZ
He a t P um p s
3, 800 t o 19, 0 0 0 B t u /h
Ca pa c it y R a n g e
15-17.5 SEER
10 HSPF
(MS-A12WA Model Shown)
ms COOLING-ONLY
Non-inverter
Indoor Unit
Outdoor Unit
Model Name
Cooling *1
Power Supply
Voltage
MS-A12WA
MU-A12WA
12,000
Rated Capacity
Btu/h
9,500
Capacity Range
Btu/h
-
-
Total Input
W
870
1,070
Energy Efficiency
Moisture Removal
Sensible Heat Factor
Phase, Cycle, Voltage
Indoor - Outdoor L1-N
Indoor - Outdoor N-2
Indoor - Remote Controller
MCA
Fan Motor
SEER
Pints/h
Airflow (Lo-Med-Hi
Powerful)
Indoor Unit
MS-A09WA
MU-A09WA
Sound Pressure Level
(Lo-Med-Hi)
External Finish Color
Dimension Unit
Weight Unit
Field Drainpipe Size O.D.
A
F.L.A.
DRY (CFM)
WET (CFM)
dB(A)
13
2.7
3.2
0.68
0.70
1 Phase, 60Hz, 115V *2
AC 115V
AC 115V
Wireless Type
1.2
0.95
183-261-335-367
222-286-406-446
162-233-300-328
198-254-363-399
26-32-40-42
W: In.
D: In.
H: In.
11-3/4
Lbs.
In.
23
5/8
MCA
A
14
MOCP
(Time Delay) A
15
20
Fan Motor
F.L.A.
0.63
0.93
Model (Type)
Compressor
Outdoor Unit
Airflow
Single Rotary
9.3
L.R.A.
47
56
CFM
1,083
1,327
Weight
dB(A)
47
Munsell No. 3Y 7.8/1.1
31-1/2
33-7/16
D: In.
11-1/4
11-7/16
H: In.
21-5/8
23-13/16
Lbs.
78
Type
Refrigerant
Type
Charge
Oil
Lbs., Oz.
Type (Fl. Oz.)
2, 5
Gas Side O.D.
In.
3/8
Connection Method
Height Difference (Max.)
52
W: In.
Remote Controller
Liquid Side O.D.
10.82
Capillary Tube
External Finish Color
Dimensions
16
R.L.A.
Refrigerant Control
Sound Pressure Level
(Cooling) *1
Refrigerant Pipe
33-38-45
Munsell No. 1.0Y 9.2/0.2
30-11/16
8-1/4
96
Wireless Remote
R410A
Ft.
3, 1
NE022 (10.8)
1/2
1/4
35
Length (Max.)
65
Indoor/Outdoor
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling) - Indoor D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts.
10
msy COOLING-ONLY (cont.)
Tax
C redit
Indoor Unit
Outdoor Unit
Model Name
Cooling *1
Power Supply
Voltage
9,000
12,000
14,000
17,200
22,500
30,700
34,600
3,800-12,200
3,800-13,600
8,200-31,400
1,800 (5703,580)
9,800-34,600
W
3,700-18,700
1,640 (2402,070)
9,800-30,700
Total Input
3,100-18,200
1,080 (1602,000)
Energy Efficiency
SEER
21
19.2
19
Moisture Removal
Sensible Heat Factor
Phase, Cycle, Voltage
Indoor - Outdoor S1 - S2
Indoor - Outdoor S2 - S3
Indoor - Remote Controller
MCA
Fan Motor
Pints/h
Sound Pressure Level at Cooling
(Quiet-Lo-Med-Hi-Super Hi) *1
External Finish Color
A
F.L.A.
DRY
(CFM)
WET
(CFM)
dB(A)
660 (205-1,200) 960 (205-1,300)
21
20.5
1.5
0.82
2.5
0.74
Charge
Oil
Connection
Method
Gas Side O.D.
Liquid Side O.D.
Height Difference (Max.)
Length (Max.)
2.7
4.6
0.75
0.71
1-phase, 60Hz, 208 / 230V *2
AC 208 / 230V
DC12-24V
Wireless Type (Optional Wired Controller: DC 12V)
1.0
0.76
205-272-335230-275-339388-469-628-738
420-533
420-533
170-237-300194-240-304347-420-562-661
385-498
385-498
109-134-201-286-364
19-22-30-37-43 19-22-30-37-45 26-32-38-44-49 28-33-38-44-49
16
15.1
9.9
0.64
11.9
0.62
389-639-848
350-576-763
34-41-49-53
32-42-49
Munsell No. 1.0Y 9.2 / 0.2
W: In.
D: In.
H: In.
Lbs.
In.
A
A
F.L.A.
Model
(Type)
R.L.A.
L.R.A.
CFM
Airflow (Cooling)
Refrigerant Control
Sound Pressure Level at Cooling *1 dB(A)
External Finish Color
W: In.
D: In.
Dimensions
Weight
Remote Controller Type
Type
3,380 (620-3,380) 4,240 (620-4,240)
2.7
0.80
145-170-237-321-399
31-7/16
9-1/8
11-5/8
22
Lbs.
Lbs.,
Oz.
Type
(fl. oz.)
In.
In.
Ft.
Ft.
43-5/16
9-3/8
12-13/16
37
46-1/16
11-5/8
14-3/8
40
17.1
20
21
25
5/8
14
12
15
0.50
0.93
DC INVERTER-driven
DC INVERTER-driven Twin Rotary
4.9
6.1
1,151
6.8
8.5
1,243
1,229
46
49
H: In.
Refrigerant Pipe
Length
MSY-D36NA
MUY-D36NA
Btu/h
Compressor
Refrigerant Pipe
MSY-D30NA
MUY-D30NA
MSY-GE24NA
MUY-GE24NA
Btu/h
Weight Unit
Field Drainpipe Size O.D.
MCA
MOCP
Fan Motor
Refrigerant
MSY-GE18NA
MUY-GE18NA
Rated Capacity
Dimension Unit
Outdoor Unit
MSY-GE09NA MSY-GE12NA MSY-GE15NA
MUY-GE09NA MUY-GE12NA MUY-GE15NA
Capacity Range
Airflow at Cooling
(Quiet-Lo-Med-Hi-Super Hi) *1
Indoor Unit
Tax
Credit
10.0
12.9
12.5
16.1
1,730
1,769
Linear Expansion Valve
54
Munsell No. 3Y 7.8 / 1.1
16
20
1,941
55
56
31-1/2
11-1/4
13
13
13
21-5/8
33-7/16
34-5/8
33-7/16
66
33-1/16
77
1, 12
80
119
Wireless Remote (Optional Wired Controller)
R410A
2, 9
3, 7
NEO22 (10.8)
NEO22 (15.2)
3/8
1/4
1/2
1/4
4, 3
4, 1
FV50S (0.40)
NE022 (29.5)
5/8
3/8
40
65
Indoor/Outdoor
126
50
100
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling) - Indoor D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts.
11
Single-Zone - MS and MSY Specifications
(MSY-GE17NA Model Shown)
MSZ heat pump
(MSZ-FE12NA Model Shown)
Tax
Credit
Indoor Unit
Outdoor Unit
Model Name
Cooling *1
Heating at 47° F *2
Heating at 17° F *3
Heating at 5° F
Power Supply
Voltage
Indoor Unit
MSZ-GE09NA
MUZ-GE09NA
MSZ-FE09NA
MUZ-FE09NA
Btu/h
9,000
9,000
12,000
12,000
14,000
Btu/h
3,800-12,200
2,800-9,000
3,800-13,600
2,800-12,000
3,100-18,200
Total Input
W
660 (205-1,200)
580 (160-650)
960 (205-1,300)
930 (160-960)
1,080 (160-2,000)
Energy Efficiency
SEER
21
26
20.5
23
21
Moisture Removal
Sensible Heat Factor
Rated Capacity
Capacity Range
Total Input
HSPF (IV)
Rated Capacity
Rated Total Input
Maximum Capacity
Maximum Capacity
Phase, Cycle, Voltage
Indoor - Outdoor S1 - S2
Indoor - Outdoor S2 - S3
Indoor - Remote Controller
MCA
Fan Motor
Pints/h
1.5
0.82
10,900
4,500-14,100
760 (255-1,200)
2.1
0.76
10,900
3,000-18,000
710 (150-2,250)
10
6,700
650
12,500
10,900
2.5
0.74
14,400
5,500-18,100
1,170 (340-1,660)
2.9
0.73
13,600
3,000-21,000
950 (150-2,250)
10.6
8,300
800
13,600
12,500
2.7
0.80
18,000
4,800-20,900
1,600 (270-2,010)
10
11,300
1,150
15,900
13,022
Btu/h
Btu/h
W
Btu/h/W
Btu/h
W
Btu/h
Btu/h
A
F.L.A.
Airflow at Cooling (Lo-Med-Hi-Super DRY (CFM)
HI-Powerful) *1
WET (CFM)
Airflow at Heating (Lo-Med-Hi-Super
WET (CFM)
HI-Powerful) *2
Sound Pressure Level at Cooling (LodB(A)
Med-Hi-Super HI-Powerful) *1
Sound Pressure Level at Heating
dB(A)
(Lo-Med-Hi-Super HI-Powerful) *2
6,600
700
8,700
7,061
145-170-237-321-399
109-134-201-286-364
8,800
900
11,200
9,194
1-phase, 60Hz, 208 / 230V *4
AC 208 / 230V
DC12-24V
Wireless Type (Optional Wired Controller: DC 12V)
1.0
0.76
162-226-339-381
145-170-237-321-399
162-226-381-410
144-202-307-343
109-134-201-286-364
144-202-350-367
145-170-237-321-406
166-240-367-381
145-170-237-321-406
166-240-399-420
205-247-304-367-463
19-22-30-37-43
22-31-39-42
19-22-30-37-45
22-33-43-45
26-32-38-44-49
19-22-30-37-43
22-31-40-42
19-22-30-37-43
22-33-43-44
26-30-35-40-46
31-7/16
9-1/8
31-3/8
10-1/8
31-3/8
10-1/8
31-7/16
9-1/8
22
27
27
22
0.50
0.56
0.50
Airflow (Cooling/Heating)
Refrigerant Control
Defrost Method
Sound Pressure Level at Cooling *1
Sound Pressure Level at Heating *2
External Finish Color
Dimensions
Weight
R.L.A.
L.R.A.
CFM
6.6
8.2
1,151 / 1,225
0.56
DC INVERTER-driven Twin
Rotary
8.6
10.8
1,102 / 1,187
dB(A)
dB(A)
46
50
48
49
W: In.
D: In.
H: In.
Lbs.
66
80
Refrigerant Pipe Length
Connection Method
DC INVERTER-driven
Type
Type
Charge
Oil
Gas Side O.D.
Liquid Side O.D.
Height Difference (Max.)
Length (Max.)
Indoor/Outdoor
205-272-335-420-533
170-237-300-385-498
Munsell No. 1.0Y 9.2 / 0.2
W: In.
D: In.
H: In.
Lbs.
In.
A
A
F.L.A.
Model (Type)
Compressor
Refrigerant Pipe
MSZ-GE15NA
MUZ-GE15NA
Capacity Range
Weight Unit
Field Drainpipe Size O.D.
MCA
MOCP
Fan Motor
Refrigerant
MSZ-FE12NA
MUZ-FE12NA
Rated Capacity
Dimension Unit
Remote Controller
Tax
Credit
Tax
Credit
MSZ-GE12NA
MUZ-GE12NA
External Finish Color
Outdoor Unit
Tax
Credit
Tax
Credit
31-7/16
9-1/8
11-5/8
22
5/8
12
15
0.50
DC INVERTER-driven
DC INVERTER-driven Twin Rotary
6.6
8.2
1,229 / 1,172
Linear Expansion Valve
Reverse Cycle
8.6
10.8
1,102 / 1,187
7.4
9.3
1,243 / 1,229
49
51
Munsell No. 3Y 7.8 / 1.1
31-1/2
11-1/4
21-5/8
77
48
49
49
51
80
Wireless Remote (Optional Wired Controller)
R410A
Lbs., Oz.
Type (fl. oz.)
In.
In.
Ft.
Ft.
1, 12
2, 9
NEO22 (10.8)
3/8
1/4
NE022 (15.2)
1/2
1/4
40
65
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
*4. Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts.
12
MSZ heat pump
(cont.)
Tax
Credit
Indoor Unit
Outdoor Unit
Model Name
Cooling *1
MSZ-GE18NA
MUZ-GE18NA
Power Supply
Voltage
17,200
18,000
22,500
30,700
33,200
3,700-18,700
8,200-25,200
8,200-31,400
9,800-30,700
9,800-33,200
Total Input
W
1,640 (240-2,070)
1,270 (570-2,280)
1,800 (570- 3,580)
Energy Efficiency
SEER
19.2
20.2
19.0
Moisture Removal
Pints/h
4.6
2.7
2.7
9.9
11.3
0.71
0.84
0.75
0.64
0.62
Btu/h
21,600
21,600
27,600
32,600
35,200
Btu/h
3,500-25,200
7,500-29,700
7,500-36,900
8,700-34,000
8,700-36,000
1,900 (230-2,680)
1,540 (520-2,240)
2,340 (520- 3,650)
10
10.3
10
Total Input
W
HSPF (Region IV)
Btu/h/W
Rated Capacity
Btu/h
13,400
11,700
16,000
19,500
W
1,450
1,240
3,290
2,400
2,820
Maximum Capacity
Btu/h
17,200
19,300
24,600
20,800
22,800
Maximum Capacity
Btu/h
13,562
21,600
21,160
16,305
19,090
Phase, Cycle, Voltage
Indoor - Outdoor S1-S2
Indoor - Outdoor S2-S3
Indoor - Remote Controller
MCA
Fan Motor
3,360 (520-3,600) 3,840 (520-4,100)
8.2
21,800
1 Phase, 60Hz, 208/230V *4
AC 208 / 230V
DC12-24
Wireless Type (Optional Wired Controller: DC12V)
1.0
0.76
A
F.L.A.
DRY (CFM)
230-275-339-420-533
388-469-628-738
388-469-628-738
389-639-848
WET (CFM)
194-240-304-385-498
347-420-562-661
347-420-562-661
350-576-763
Airflow (Heat) (Lo-Med-Hi-Super HI-Powerful) *2
DRY (CFM)
Sound Pressure Level (Cooling) (Lo-Med-Hi-Super
HI-Powerful) *1
dB(A)
Sound Pressure Level (Heating) (Lo-Med-Hi-Super
HI-Powerful) *2
External Finish Color
230-275-339-431-512
388-469-628-738
388-469-628-738
445-639-848
28-33-38-44-49
34-41-49-53
34-41-49-53
32-42-49
28-33-38-43-48
32-41-49-52
32-41-49-52
34-42-49-49
Munsell No. 1.0Y 9.2/0.2
W: In.
31-7/16
43-5/16
46-1/16
D: In.
9-1/8
9-3/8
11-5/8
H: In.
11-5/8
12-13/16
14-3/8
Weight Unit
Field Drainpipe Size O.D.
MCA
Lbs.
In.
A
22
37
14
17.1
21
MOCP
Fan Motor
A
F.L.A.
Model (Type)
15
20
25
Compressor
R.L.A.
10.0
12.9
L.R.A.
12.5
16.1
20
CFM
1,730 / 1,659
1,769 / 1,701
1,941
Refrigerant Control
Defrost Method
Sound Pressure Level at Cooling *1
Sound Pressure Level at Heating *2
External Finish Color
dB(A)
dB(A)
0.93
DC INVERTER-driven Twin Rotary
Weight
54
56
Lbs.
34-5/8
141
Wireless Remote (Optional Wired Controller)
R410A
Charge
Lbs., Oz.
Oil
Type (Fl. Oz.)
Height Difference (Max.)
Length (Max.)
Indoor/Outdoor
33-7/16
119
Type
Liquid Side O.D.
56
57
13
33-7/16
Remote Controller Type
Gas Side O.D.
16
Linear Expansion Valve
Reverse Cycle
55
55
Munsell No. 3Y 7.8/1.1
33-1/16
D: In.
H: In.
40
5/8
W: In.
Connection
Method
14.5
Rated Capacity
Dimensions
Refrigerant Pipe
3,850 (620-3,850) 4,360 (620-4,360)
Capacity Range
Airflow
Refrigerant
MSZ-D36NA
MUZ-D36NA
Btu/h
Dimension Unit
Outdoor Unit
MSZ-D30NA
MUZ-D30NA
Btu/h
Airflow (Cool) (Lo-Med-Hi-Super HI-Powerful) *1
Indoor Unit
MSZ-GE24NA
MUZ-GE24NA
Rated Capacity
Heating at 17º F *3 Total Input
Heating at 5º F
MSZ-FE18NA
MUZ-FE18NA
Capacity Range
Sensible Heat Factor
Heating at 47º F *2
Tax
Credit
In.
Ft.
3, 7
4, 3
4, 10
NE022 (15.2)
FV50S (13.5)
NE022 (29)
1/2
5/8
1/4
3/8
50
100
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
*4. Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts.
13
Single-Zone - MSZ Specifications
(MSY(Z)-D30NA Model Shown)
(SEZ-KD12NA Model Shown)
SEZ heat pump
Tax
Credit
Indoor Unit
Outdoor Unit
Model Name
Cooling *1
8,100
11,500
14,100
17,200
Btu/h
3,800-10,900
3,800-13,300
3,800-17,000
3,800-19,000
670
920
1,170
1,380
Total Input
External Static Pressure *3
Sound Pressure Level
External Finish
Weight Unit
Field Drainpipe Size O.D.
MCA
MOCP
Fan Motor
Compressor
Airflow (Cooling/Heating)
Refrigerant Control
Defrost Method
Sound Pressure Level at Cooling *1
Sound Pressure Level at Heating *2
External Finish Color
Dimensions
W
SEER
Pints/h
Btu/h
Btu/h
W
Btu/h/W
Btu/h
W
Btu/h
A
F.L.A.
DRY (CFM)
WET (CFM)
In. W.G.
dB(A)
W: In.
D: In.
H: In.
Lbs.
In.
A
A
F.L.A.
Model
(Type)
R.L.A.
L.R.A.
CFM
dB(A)
dB(A)
15
1.5
0.80
10,900
4,800-14,100
1,020
16
15.5
17.5
2.4
2.6
3.4
0.76
0.80
0.79
13,600
18,000
21,600
4,800-16,400
4,800-21,100
4,800-24,900
1,140
1,500
1,700
10.0
6,700
9,000
11,900
13,100
810
920
1,200
1,350
7,300
9,800
13,700
15,000
1 Phase, 60Hz, 208 / 230V *4
AC 208-230V
DC 12-24V
See optional accessories chart (pg 26 and 27)
1
0.51
0.57
0.74
194-247-317
247-317-388
353-441-529
423-529-635
174-222-285
222-285-349
317-396-476
381-476-572
0.02-0.06-0.14-0.20
23-26-30
23-28-33
30-34-37
30-34-38
Galvanized-Steel Sheets
31-1/8
39
46-7/8
27-9/16
7-7/8
42
50
54
62
1-1/4
12
14
15
0.50
0.93
DC Inverter
6.6
8.2
1,151/1,225
46
50
W: In.
D: In.
H: In.
Weight
Remote Controller Type
Type
Charge
Refrigerant
Oil
Refrigerant Pipe
Length
Connection
Method
Gas Side O.D.
Liquid Side O.D.
Height Difference (Max.)
Length (Max.)
Lbs.
Lbs., Oz.
Type (fl.
oz.)
In.
In.
Ft.
Ft.
DC Inverter Twin Rotary
7.4
9.3
1,229/1,172
1,243/1,229
Linear Expansion Valve
Reverse Cycle
49
51
Munsell No. 3Y 7.8/1.1
31-1/2
11-1/4
10
12.5
1,730/1,659
54
56
33-1/6
13
21-5/8
33-7/16
66
77
80
119
See optional accessories chart (pg 26 and 27)
R410A
1, 16
2, 9
3, 16
Indoor/Outdoor
NEO22 (10.8)
NEO22 (15.2)
3/8
1/2
1/4
40
65
50
100
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
*4. Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts.
14
SEZ-KD18NA4
SUZ-KA18NA
Btu/h
Dimension Unit
Refrigerant Pipe
SEZ-KD15NA4
SUZ-KA15NA
Capacity Range
Airflow (Lo-Med-Hi)
Outdoor Unit
SEZ-KD12NA4
SUZ-KA12NA
Rated Capacity
Energy Efficiency
Moisture Removal
Sensible Heat Factor
Rated Capacity
Capacity Range
Heating at 47° F *2
Total Input
HSPF (IV)
Rated Capacity
Heating at 17° F *3 Rated Total Input
Maximum Capacity
Power Supply
Phase, Cycle, Voltage
Indoor - Outdoor S1 - S2
Voltage
Indoor - Outdoor S2 - S3
Indoor - Remote Controller
MCA
Fan Motor
Indoor Unit
SEZ-KD09NA4
SUZ-KA09NA
Tax
Credit
Middle
[0.04] [0.04]
Low Low
RatedRated
point point
0
0
[141] [141] [176] [176] [212] [212] [247] [247] [282] [282] [318] [318] [353] [353]
rate [CFM]
AirflowAirflow
rate [CFM]
Limit
Rated point
[212]
[247]
[282]
Airflow rate [CFM]
[318]
SEZ-KD15NA4
SEZ-KD15NA4
(External
(External
static static
pressure
pressure
0.02[in.WG])
0.02[in.WG])
208/230V
208/230V
60Hz 60Hz
SEZ-KD12NA4
SEZ-KD12NA4
208/230V 60Hz
Rated point
High
Middle
Middle
Rated point
Low
[0.08]
[0.04]
0
0
[212]
[141]
[318]
[353]
[282]
[212] Airflow[247]
rate [CFM][282]
Airflow rate [CFM]
[247]
[176]
[388]
[318]
[0.16]
[0.28]
[0.24]
[0.12]
High
[0.20]
Rated point
Middle
Low
[0.12]
0
[212]
[424]
V 60Hz
V 60Hz
[318]
[353]
[388]
[424]
[459]
Airflow rate [CFM]
[247]
ted point
Rated point
65] [600] [636] [671]
[494]
[530]
[565]
0V 60Hz
[494]
[282]
[318]
[353]
Airflow rate [CFM]
[530]
[388]
208/230V 60Hz
(External
50 static pressure 0.20[in.WG]) 208/230V 60Hz
High
High
Rated point
Middle
Middle
Low
Low
2010
[0.08]
[0.04]
Low
Rated point
Rated point
Low
Low
Low
[0.04]
[0.04]0
0
[282] [282]
[318] [318]
[353] [353]
[388] [388]
[424] [424]
[459] [459]
[494] [494]
[530] [530]
[565] [565]
0
0
Airflow Airflow
rate [CFM]
rate [CFM]
[212]
[247]
[282]
[318]
[353]
[388]
[424]
[318]
[353]
[388]
[424]
[212]
[247]
[282]
Airflow rateAirflow
[CFM]rate [CFM]
SEZ-KD18NA4
SEZ-KD18NA4
SEZ-KD15NA4
SEZ-KD15NA4
(External
(External
staticstatic
pressure
pressure
0.06[in.WG])
0.06[in.WG])
208/230V
208/230V
60Hz60Hz
(External
(External
static static
pressure
pressure
0.20[in.WG])
0.20[in.WG])
208/230V
208/230V
60Hz 60Hz
50 50
Limit
Limit Limit
Limit
70
70
[0.28]
40 [0.28]
40
[0.16][0.16]
High High
High High
Low
30
5030 50
[0.20]
[0.20]
[0.12][0.12]
40
40
[0.16] [0.16]
20 20
[0.08][0.08]
30
30
[0.12] [0.12]
2010 20
10
[0.08]
[0.08]
[0.04][0.04]
Low
RatedRated
pointpoint
Rated point
Rated point
Middle
Middle
Middle
Middle
Low Low
Low Low
RatedRated
pointpoint
10
10
[0.04] [0.04]
0
0
0 [318] [318]
0 [353] [353]
[388] [388]
[424] [424]
[459] [459]
[494] [494]
[530] [530]
[565] [565]
[600] [600]
[636] [636]
[671] [671]
[282] [282]
[318] [318]
[353] [353]
[388]
[388]
[424]
[424]
[459]
[459]
[494] [494]
[530] [530]
[565] [565]
Airflow
Airflow
rate [CFM]
rate
[CFM]
Airflow Airflow
rate [CFM]
rate [CFM]
[565]
[0.12]
[0.04] [0.04]
[0.08]
[0.08]
0
0
0 [318] 0
[318]
[353] [353]
[388] [388]
[424] [424]
[459] [459]
[494] [494]
[530] [530]
[565] [565]
[600] [600]
[636] [636]
[671] [671]
[282] [282]
[318] [318]
[353] [353]
[388]
[388]
[424]
[424]
[459]
[459]
[494] [494]
[530] [530]
[565] [565]
Airflow
Airflow
rate [CFM]
rate
[CFM]
Airflow Airflow
rate [CFM]
rate [CFM]
[424]
SEZ-KD18NA4
SEZ-KD18NA4
SEZ-KD18NA4
SEZ-KD18NA4
(External
(External
staticstatic
pressure
pressure
0.14[in.WG])
0.14[in.WG])
208/230V
208/230V
60Hz60Hz
(External
(External
staticstatic
pressure
pressure
0.20[in.WG])
0.20[in.WG])
208/230V
208/230V
60Hz60Hz
[0.32][0.32]
LimitLimit
LimitLimit
[0.28][0.28]
5030
[0.12]
[0.20]
[353] [388] [424] [459] [494] [530] [565] [600] [636] [671]
[318]
[353]
[388]
[459]
[494]
[530]
[565]
Airflow[424]
rate [CFM]
Airflow rate [CFM]
[0.28][0.28]
[0.24][0.24]
High High
[0.20][0.20]
[0.16][0.16]
Middle
Middle
RatedRated
pointpoint
[0.12][0.12]
Rated point
10
[0.04]
0
0 [318]
[282]
Middle
Middle
LimitLimit
70
[0.28]
40
[0.16]
40
[0.16]
20
[0.08]
30
[0.12]
[0.12]
Low Low
[0.20][0.20]
Middle
Middle
RatedRated
pointpoint
[0.16][0.16]
[0.12][0.12]
[0.08][0.08]
[0.08][0.08]
[0.04][0.04]
[0.04][0.04]
0
0
[318] [318]
[353] [353]
[388] [388]
[424] [424]
[459] [459]
[494] [494]
[530] [530]
[565] [565]
[600] [600]
[636] [636]
[671] [671]
High High
[0.24][0.24]
Low Low
0
0
[318] [318]
[353] [353]
[388] [388]
[424] [424]
[459] [459]
[494] [494]
[530] [530]
[565] [565]
[600] [600]
[636] [636]
[671] [671]
Airflow
Airflow
rate [CFM]
rate [CFM]
Airflow
Airflow
rate [CFM]
rate [CFM]
Note: ESP @ 208/230V, 60 Hz. See manual for Static Performance Curve, including @ 0.02 in W.G.
SEZ-KD18NA4
(External static pressure 0.20[in.WG]) 208/230V 60Hz
LIMITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts.
[0.32]
High
MiddleMiddle
Middle Middle
[0.16]
[0.16]
[0.08] [0.08]
[0.32][0.32]
60
[0.24]
High
Rated point
Rated point
MiddleMiddle
Low Low
SEZ-KD18NA4
SEZ-KD15NA4
(External static pressure 0.06[in.WG])
External static pressure [in.WG]
External static pressure [in.WG]
Limit
High High
[0.04] [0.04]
[0.20]
80
[0.32]
Limit
High High
[0.04][0.04]
[0.08] [0.08]
[0.04]
High High
Rated point
Rated point
High
60
60
[0.24] [0.24]
[0.12] [0.12]
Rated point
[0.24]
[0.12] [0.12]
[0.20]
[0.20]
Limit Limit
[0.08][0.08]
[0.16] [0.16]
High
Middle
[0.08]
[0.16]
0
[0.04]
[282]
[0.24]
[0.20]
80 [0.20]
80
[0.32] [0.32]
[0.20] [0.20]
External static pressure [in.WG]
[388]
[565]
Rated point
Rated point
Low
[0.12][0.12]
[0.24] [0.24]
External static pressure [in.WG]
[530]
Low
Limit
[0.28]
[0.16] [0.16]
[0.28]
LimitLimit
Low
494]
Low
Middle
[0.28] [0.28]
External static pressure [in.WG]
External static pressure [in.WG]
External
static pressure
[in.WG]
External
static pressure
[in.WG]
[0.08]
Middle
High
[0.16][0.16]
[0.32] [0.32]
Limit
[0.08]
ed point
Rated point
High
Rated point
MiddleMiddle
(External
(External
static static
pressure
pressure
0.14[in.WG])
0.14[in.WG])
208/230V
208/230V
60Hz 60Hz
Limit
High
point
High High
[0.16]
[0.12]
[0.12]
[0.04] [0.04]
[0.32]
High
[0.20]
SEZ-KD18NA4
SEZ-KD18NA4
SEZ-KD15NA4
SEZ-KD15NA4
(External
(External
staticstatic
pressure
pressure
0.02[in.WG])
0.02[in.WG])
208/230V
208/230V
60Hz60Hz
[0.20]
(External
static pressure 0.20[in.WG]) 208/230V 60Hz
Limit
Limit
[0.08] [0.08]
[0.16]
SEZ-KD12NA4
Limit
Limit
[0.04] 0 [0.04]
0
[282] [282]
[318] [318]
[353] [353]
[388] [388]
[424] [424]
[459] [459]
[494] [494]
[530] [530]
[565] [565]
0
0
Airflow Airflow
rate [CFM]
rate [CFM]
[424]
[212]
[247]
[282]
[318]
[353]
[388]
[424]
[212]
[247]
[282]
[318]
[353]
[388]
[424]
[353]
Airflow rateAirflow
[CFM]rate [CFM]
(External static pressure 0.06[in.WG]) 208/230V 60Hz
60Hz
[0.24]
Low
SEZ-KD15NA4
60Hz
[0.20]
[0.08]
[0.04]
[424]
[353]
[0.24]
Low
oint
[388]
[318]
[0.28]
[0.12] [0.12]
External static pressure [in.WG]
External static pressure [in.WG]
Limit
[0.12]
Limit
External
Externalstatic
staticpressure
pressure[in.WG]
[in.WG]
High
[0.16]
[0.08]
Low
Low
[0.32]
[0.32]
External static pressure [in.WG]
External static pressure [in.WG]
oint
High
Rated point
Rated point
Limit Limit
[0.32]
[0.28]
[0.24]
[0.12]
[0.20]
Middle
Low Low
[0.04] 0
[0.04]
0
[212]
[247]
[282]
[318]
[353]
[388]
[424]
[212]
[247]
[282]
[318]
[353]
[388]
[424]
0
0
Airflow rateAirflow
[CFM]rate [CFM]
[141] [141] [176] [176] [212] [212] [247] [247] [282] [282] [318] [318] [353] [353]
rate [CFM]
AirflowAirflow
rate [CFM]
External static pressure [in.WG]
High
Limit
External static pressure [in.WG]
External
static
pressure
[in.WG]
External
static
pressure
[in.WG]
Limit
Middle
[0.12] [0.12]
Limit Limit
[0.28]
[0.16]
High
High
Middle
Middle
[0.16] [0.16]
[0.08]
[0.08]
External static pressure [in.WG]
[0.32]
RatedRated
point point
[0.20] [0.20]
[0.04]
[0.04]
[0.08] [0.08]
Limit
Limit
(External
static pressure
0.20[in.WG])
208/230V
(External
static pressure
0.20[in.WG])
208/230V
60Hz 60Hz
[0.20] [0.20]
[0.16] [0.16]
[0.32]
High High
[0.24] [0.24]
[0.12]
[0.12]
SEZ-KD15NA4
SEZ-KD15NA4
(External
(External
static static
pressure
pressure
0.06[in.WG])
0.06[in.WG])
208/230V
208/230V
60Hz 60Hz
SEZ-KD12NA4
SEZ-KD12NA4
static pressure
0.14[in.WG])
208/230V
(External(External
static pressure
0.14[in.WG])
208/230V
60Hz 60Hz
(External
[0.20] static pressure 0.20[in.WG]) 208/230V 60Hz
External
Externalstatic
staticpressure
pressure[in.WG]
[in.WG]
60Hz
60Hz
RatedRated
point pointHigh
High
Middle
Middle
Middle Middle
Limit Limit
[0.16]
[0.16]
[0.28] [0.28]
External static pressure [in.WG]
External static pressure [in.WG]
SEZ-KD12NA4
(External static pressure 0.06[in.WG])
SEZ-KD09NA4
40
40
[0.16] [0.16]
External
static
pressure
[in.WG]
External
static
pressure
[in.WG]
[176]
Limit
Limit
High High
Rated point
Rated point
LowLow Low
Low
10
10
[0.04]
0
0[0.04]
[212]
[247]
[282]
[318]
[353]
[388]
[424]
[212]
[247]
[282]
[318]
[353]
[388]
[424]
0
0
Airflow rateAirflow
[CFM]rate [CFM]
[353]
[141] [141] [176] [176] [212] [212] [247] [247] [282] [282] [318] [318] [353] [353]
rate [CFM]
AirflowAirflow
rate [CFM]
point
0
[141]
60
60
[0.24] [0.24]
30
30
[0.12] [0.12]
[0.04]
[0.04]
20
20
[0.08] [0.08]
Middle
Low
External static pressure [in.WG]
External static pressure [in.WG]
External static pressure [in.WG]
External static pressure [in.WG]
[0.08]
[353]
[0.32] [0.32]
Limit Limit
50
50
[0.20] [0.20]
[0.08]
[0.08]
High
[0.12]
[0.04]
[318]
[0.20]
(External
pressure
0.20[in.WG])
208/230V
(External
staticstatic
pressure
0.20[in.WG])
208/230V
60Hz60Hz
70
70
[0.28] [0.28]
[0.12]
[0.12]
[0.16]
External static pressure [in.WG]
igh
80
80
[0.32] [0.32]
External static pressure [in.WG]
Limit
[0.16]
(External
pressure
0.14[in.WG])
208/230V
(External
staticstatic
pressure
0.14[in.WG])
208/230V
60Hz60Hz
External static pressure [in.WG]
[0.20]
SEZ-KD09NA4
SEZ-KD09NA4
[0.20]
External static pressure [in.WG]
(External static pressure 0.06[in.WG]) 208/230V 60Hz
(SEZ-KD12NA4 Model Shown)
static pressure
0.06[in.WG])
208/230V
(External(External
static pressure
0.06[in.WG])
208/230V
60Hz 60Hz
SEZ-KD09NA4
SEZ-KD09NA4
[0.16]
External
static pressure
[in.WG]
External
static pressure
[in.WG]
SEZ-KD09NA4
0Hz
SEZ-KD12NA4
SEZ-KD12NA4
static pressure
0.02[in.WG])
208/230V
(External(External
static pressure
0.02[in.WG])
208/230V
60Hz 60Hz
Single-Zone - SEZ Specifications
SEZ STATIC Performance
SEZ-KD12NA4 Curves
SEZ-KD12NA4
AND CORRECTED AIR FLOW
0
0
[141] [141] [176] [176] [212] [212] [247] [247] [282] [282] [318] [318] [353] [353]
rate [CFM]
AirflowAirflow
rate [CFM]
15
SLZ heat pump
(SLZ-KA12NA Model Shown)
Indoor Unit
Outdoor Unit
Model Name
Rated Capacity
Capacity Range
Cooling *1
Heating at 47° F *2
Heating at 17° F *3
Power Supply
Voltage
Total Input
W
Energy Efficiency
Moisture Removal
Sensible Heat Factor
Rated Capacity
Capacity Range
Total Input
HSPF (IV)
Rated Capacity
Rated Total Input
Maximum Capacity
Phase, Cycle, Voltage
Indoor - Outdoor S1 - S2
Indoor - Outdoor S2 - S3
Indoor - Remote Controller
MCA
Fan Motor
SEER
Pints/h
Airflow (Lo-Med-Hi)
Indoor Unit
Btu/h
Btu/h
Sound Pressure Level
External Finish
Dimension Unit (Grille)
Weight Unit (Grille)
Field Drainpipe Size O.D.
MCA
MOCP
Fan Motor
Btu/h
Btu/h
W
Btu/h/W
Btu/h
W
Btu/h
A
F.L.A.
DRY (CFM)
WET (CFM)
dB(A)
W: In.
D: In.
H: In.
Lbs.
In.
A
A
F.L.A.
Model (Type)
Compressor
Outdoor Unit
Airflow (Cooling/Heating)
Refrigerant Control
Defrost Method
Sound Pressure Level at Cooling *1
Sound Pressure Level at Heating *2
External Finish Color
Dimensions
R.L.A.
L.R.A.
CFM
dB(A)
dB(A)
W: In.
D: In.
SLZ-KA09NA
SUZ-KA09NA
SLZ-KA12NA
SUZ-KA12NA
SLZ-KA15NA
SUZ-KA15NA
8,400
3,100-10,900
11,100
3,100-13,300
15,000
3,100-22,200
700
920
1,460
15
1.2
0.80
10,900
3,100-14,100
930
15.4
16
2.3
4.5
0.76
0.80
13,600
18,000
3,100-17,100
3,100-17,100
1,180
1,950
9.6
6,200
8,300
10,200
740
930
1,310
8,300
10,200
12,000
1 Phase, 60Hz, 208 / 230V *4
AC 208-230V
DC 12-24V
See optional accessories chart (pg 26 and 27)
1
0.23
0.28
0.28
280-320-350
280-320-390
280-320-390
250-290-320
250-290-350
250-290-350
29-32-38
30-34-39
31-35-40
Galvanized-Steel Sheets; Grille: Munsell 6.4Y 8.9/0.4
22-7/16 (25-5/8)
22-7/16 (25-5/8)
8-3/16 (13/16)
36 (7)
1-1/4
12
15
0.50
DC INVERTER-driven
DC INVERTER-driven
Twin Rotary
6.6
7.4
8.2
9.3
1,151/1,225
1,229/1,172
1,243/1,229
Linear Expansion Valve
Reverse Cycle
46
49
50
51
Munsell No. 3Y 7.8/1.1
31-1/2
11-1/4
H: In.
Refrigerant
Refrigerant Pipe
Refrigerant Pipe Length
Connection Method
Weight
Type
Charge
Oil
Gas Side O.D.
Liquid Side O.D.
Height Difference (Max.)
Length (Max.)
Indoor/Outdoor
Lbs.
Lbs., Oz.
Type (fl. oz.)
In.
In.
Ft.
Ft.
21-5/8
66
77
R410A
1, 16
2, 9
NEO22 (10.8)
3/8
1/4
40
65
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
*4. Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts.
16
80
NEO22 (15.2)
1/2
MHK1 WIRELESS REMOTE CONTROLLER KIT
MRCH1 WIRELESS REMOTE CONTROLLER
•
•
•
•
Backlit, easy–to–read display
Dual setpoint control with system changeover
Enabled with RedLINK™ reliability
Compatible with MCCH1
Portable Central Controller
• Installs Anywhere
MIFH1 WIRELESS RECEIVER
Wireless Remote Controller
• Required for MRCH1 Wireless
Remote Controller
• Enabled with RedLINK reliability
Wireless Receiver
Function
Description
ON/OFF
On/Off operation for a single indoor unit
Operation Mode
Cool / Drying / Auto / Heat / Fan only
Available operation modes dependant on connected system.
Temperature Setting
Set temperature from 50°F – 87°F depending on operation mode and
connected system
System Changeover Deadband Value
2-8°F
Schedule Operation
5-2, 5-1-1
Fan Speed Setting
Hi/Mid-2/Mid-1/Low/Auto
Available fan speed settings dependant on connected system.
Air Flow Direction Setting
Air flow angles: 100o - 80o - 60o - 40o and oscilate
Available air flow direction settings dependant on connected system.
Permit/Prohibit Function
Individual prohibit operations for each remote controller function (ON/
OFF, Set Temperature, and Operation Mode).
Space Temperature
Displays the measured space temperature.
Error Indication
Displays error code.
Display Outside Temperature and
Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - (W x D x H)
Remote Controller: 5-3/16" x 1-1/2" x 3-9/16"
Receiver: 3-1/4" x 1-5/16" x 6-7/16"
Operating Ambient Temperature
Remote Controller: 32 - 120°F
Receiver: -40 – 165°F
Operating Ambient Humidity
Remote Controller: 5% - 90% RH (non-condensing)
Receiver: 5% - 90% RH (non-condensing)
Power Supply
2 AA batteries
MHK1 Kit includes
MRCH1
Wireless Wall-Mounted Remote Controllers
MIFH1
Wireless Receiver
MRC1
Cable
Accessories
MCCH1
MOS1
* SEZ-4 and SLZ 1:1 systems with SUZ outdoor unit
Portable Central Controllers
Outside Air Sensor
17
Single-Zone - SEZ / SLZ Specifications
Exclusive for INVERTER-driven Mr. Slim® Systems*
multiple rooms with individual control from a single system
Enjoy ideal levels of comfort in the rooms you use most with our multi–room system. Each room (zone)
operates independently. People in different rooms – the kitchen, master bedroom, or living room – can enjoy
temperature settings that make each of them most comfortable.
If you’re looking for a complete comfort solution for several different rooms, the MXZ multi-room
system is the right choice. The system is flexible enough to conform to a particular cooling and heating
need and offers numerous different indoor unit combinations. In addition, up to eight indoor units
can be connected to one outdoor unit. Now with a SEZ horizontal ducted unit and a MFZ floorstanding unit homeowners can enjoy an even greater range of zoning options provided
by an MXZ system.
An MXZ multi-room system is an excellent choice for supplementing capacity
to a current system, conditioning newly furnished spaces, or new additions
and replacing a system within a home. Homeowners can also benefit
from lower energy costs year-round while staying comfortable thanks
to Mitsubishi Electric’s energy-efficient technologies that are a part
of every system that we make.
To add to the level of energy efficiency, the MXZ-2B20NA
and MXZ-3B24NA systems qualify for both
ENERGY STAR® and the federal tax credit
(See details on page 21 for applicable indoor
unit combinations).
At right: a single level home with
several system types represented.
SEZ Indoor Unit
(For illustrative purposes only)
MFZ Floor-Standing Indoor Units
for MXZ Heat Pump Systems
Floor-standing indoor unit mounts on floor or on wall up
to 5" above floor and has front panel access to the filter
for ease of cleaning.
The MFZ units provide energy–efficient solutions to
provide personalized comfort for difficult areas that may
be smaller or don’t have usable space on the walls.
MFZ units on MXZ systems include
the following features:
• Top and bottom discharge vanes
• Hot-start technology
• Quiet operation
• Wireless remote control
(optional wall-mounted controller)
18
MXZ Out door Unit
MSZ Wall-Mounted Indoor Units for
MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities, each
wall-mounted indoor unit mounts high on a wall and connects to
a branch box or the outdoor unit by a refrigerant line run via a 3”
hole. The MSZ units provide highly efficient solutions to cooling
and heating needs and provide personalized comfort for the
individual zones in which they are installed.
Multi-Zone Overview
MSZ units on MXZ systems include the following features:
• Sleek, flat panel design
• Hot-start technology
• Quiet operation
• i-see™ sensor technology (MSZ-FE09/12NA models only)
• Enhanced filtration system (MSZ-FE09/12NA models only)
• Wireless remote control
(optional wired wall-mounted controller)
MSZ Indoor Unit
M UZ O utdoor Unit
SLZ Ceiling-Recessed Indoor
Units for MXZ Heat Pump
Systems
The new SLZ-KA ceiling casette systems offer
a wide air-flow pattern for better air distribution
offered to your customers. Installation can be
done in a hard ceiling (with a access panel for
servicing) or placed into a 2x2' drop ceiling. With
a built-in drain lift mechanism for condensate
removal and a 4" ventilation air intake knockout
option the SLZ is ready to handle a variety of
installation needs.
SLZ units on MXZ systems include the
following features:
• Wide air-flow pattern for better air distibution
• 4" ventillation air intake knockout
• Built-in condensate lift mechanism
SEZ Horizontal Ducted Indoor Units
for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the
added benefit of being concealed to provide virtually no visual footprint within
the conditioned space other than a register and grille for the air to flow. With the
use of short run ductwork, these units can provide comfort to a single room that
needs air dispersed evenly throughout the space,
unusually shaped rooms, and adjacent rooms.
The SEZ unit on MXZ systems include the following features:
• Concealed design for short-run ductwork
• Quiet operation
• Built-in condensate lift mechanism
19
Diamond Comfort MXZ Multi-zone systems
MXZ-B Series multi-zone systems provide personalized comfort control and energy
efficiency in up to eight rooms with only a single outdoor unit. The MXZ-B Series system
features include:
•
•
•
•
•
•
Individual zone control
Mix and match flexibility of indoor unit styles and combinations
A wide range of indoor unit capacities that match the room size and requirements
Flexible design options to tackle the most challenging multi-room installations
Efficient systems, including three systems [mxz series] that meet energy star® and
federal tax credit requirements
Simple, quick, and cost-effective installation keeps install costs down on new construction,
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number, style, and capacity of the indoor units installed
with each Multi-Zone System.
MX Z- 2 B 2 0 N A - 1 (2 :1 )
O u t d o o r U n i t
M XZ- 3B 24N A ( 2: 1, 3: 1)
O u t door Un i t
SEZ-K D 1 2 NA
In d oor Un it
M SZ -GE09NA
I n d oor Units
MSZ-GE06NA
Indoor Unit
MSZ-GE06NA
Indoor Unit
(At least two indoor units
must be installed.)
(Two indoor units must be installed.)
M X Z -3 B 3 0 N A (2 :1 , 3 :1 )
O u t d o o r U n i t
MX Z - 4 B 3 6 N A
( 2 :1 - 4 :1 )
O u td o o r U n i t
M F Z - KD0 9 NA
In d o o r Un i ts
S E Z -K D 1 2 N A
I n d o or U n i t
M S Z - GE 0 9 NA
In d o o r Un i ts
(At least two indoor units
must be installed.)
M S Z- G E 0 6 N A
I nd o o r U n it
(At least two indoor units
must be installed.)
M F Z- KD12NA
I n do or Unit
S E Z - KD1 2 NA
In d o o r Un i t
M X Z- 8 B 4 8 N A ( 2 :1 - 8:1)
O u t d oor U n i t *
Branch Box; Minimum of
one required with MXZ8B
(At least two
indoor units
must be
installed)
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD Horizontal-DUCTED
INDOOR UNIT
PEAD-A24AA
SEZ Horizontal-DUCTED
INDOOR UNIT
SEZ-KD18NA
20
MSZ INDOOR UNIT
MFZ FLOOR-STANDING
Indoor unit
MFZ-KA12NA
MSZ-FE18NA
* Illustra tion Only. N o t an appro ved s y s tem .
Multi-room MXZ-B INVERTER heat pump
Model Name
Outdoor Unit
Compressor
Airflow (Cooling/Heating)
Refrigerant Control
Defrost Method
Sound Pressure Level at
Cooling *1
Sound Pressure Level at
Heating *2
External Finish Color
Outdoor Unit *4
Dimensions
Weight
No. of Units
Type
Type
Charge
Indoor Unit
Remote Controller
Refrigerant
Oil
MXZ-2B20NA-1 *5
MXZ-3B24NA *6
MXZ-3B30NA
Btu/h
18,000/20,000
22,000/23,600
28,400/27,400
35,400/34,400
Btu/h
W
Btu/h
Btu/h
7,800-20,000
2,190 (630-2,190)
22,000/22,000
8,500-25,500
12,600-25,500
2,460 (1,000-2,950)
25,000/24,600
11,400-30,600
12,600-28,400
3,330 (1,000-3,330)
28,600/27,600
11,400-36,000
12,600-36,400
3,940 (1,000-4,020)
36,000/34,400
11,400-43,000
W
2,620 (520-2,620)
1,900 (740-2,600)
2,220 (740-2,820)
3,100 (740-3,940)
Btu/h
W
Btu/h
W
Refrigerant Pipe Length
Connection Method
14,000/14,000
16,000/15,100
1,380/1,570
2,120/2,140
18,800/17,000
18,800/18,000
2,120/2,230
2,120/2,140
1-phase, 60Hz, 208 / 230V *8
AC 208 / 230V
DC12-24V
15
20
0.93
22,200/20,300
2,430/2,340
24,600/25,400
3,340/3,450
A
A
F.L.A.
Model
(Type)
R.L.A.
L.R.A.
CFM
10.1
11
15
14.4
1,485/1,640
2,068/1,605
1,365/1,605
Linear Expansion Valve
Reverse Cycle
2,068/2,068
dB(A)
49
dB(A)
51
W: In.
D: In.
H: In.
Lbs.
33-1/16
13
27-15/16
130
2
Lbs., Oz.
Type (fl.
oz.)
In.
In.
Ft.
Gas Side O.D.
Liquid Side O.D.
Height Difference (Max.)
Lineset length for each inFt.
dividual indoor unit (Max.)
Length (Max.)
Ft.
Indoor/Outdoor
Refrigerant Pipe
12,500/12,500
1,350/1,430
14,500/14,500
1,500/1,590
MXZ-4B36NA *7
0.96
Multi-Zone Specifications
Rated Capacity
Cooling *1
Non-ducted/ Capacity Range
Ducted
Total Input
Heating at
Rated Capacity
47° F *2
Capacity Range
Indoor Unit
Non-ducted/
Total Input
Ducted
Rated Capacity
Heating at
Rated Total Input
17° F *3
Non-ducted/ Maximum Capacity
Ducted
Maximum Total Input
Power Supply
Phase, Cycle, Voltage
Indoor - Outdoor S1 - S2
Voltage
Indoor - Outdoor S2 - S3
MCA
MOCP
Fan Motor
19
DC INVERTER-driven Twin Rotary
54
49
54
49
57
Munsell No. 3.0Y 7.8 / 1.1
35-7/16
12-5/8
35-7/16
150
2, 3
2, 3
Associated with the Indoor Unit
R410A
7, 11
5, 15
NEO22 (23.7)
153
2, 3, 4
8, 13
NEO22 (29.4)
A,B: 3/8
A: 1/2; B,C: 3/8
1/4
49/33 *9
164 (A+B)
230 (A+B+C)
Flared/Flared
A: 1/2; B,C,D: 3/8
82
230 (A+B+C+D)
*Compatible with the MSZ-A, MSZ-GA, MSZ-FD, MSZ-FE, MSZ-GE, MFZ-KA and SEZ-KD series indoor units (PLA-18 & PCA-24 on the MXZ-MXZ-3B / PLA-24 & PCA-24 on the MXZ-4B)
NOTES: Test conditions are based on AHRI 210/240. One indoor unit is turned off during low-speed testing under the new test conditions. Systems actually exhibit higher energy efficiencies
during normal operation.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
*4. Refer to pages 12 and 13 for Indoor Unit specifications.
*5. Data from combination of two Indoor Units 9,000 Btu/h (non-ducted) or one 9,000 Btu/h and one 12,000 Btu/h (ducted).
*6. Data from combination of two Indoor Units 6,000 Btu/h and one 9,000 Btu/h (non-ducted) or three 9,000 Btu/h (ducted).
*7. Data from combination of four Indoor Units 9,000 Btu/h (non-ducted and ducted).
*8. Indoor units receive power from outdoor units through field-supplied interconnected wiring.
*9. 49’ Applies to installations where the outdoor unit is installed below the indoor unit.
Power factor equals 97 percent.
Specifications are subject to change without notice.
Multi- zone EN E R GY S TA R
and Tax C redit S ystems
Mode l
Indoor Unit Combi n ati o n s
SE E R
HSPF
MXZ-2B 20NA-1
2 x MSZ-GE09 N A
18
8.9
MXZ-3B 24NA
2 x MSZ-GE06N A
1 x MSZ-GE09N A
17.5
9.3
MXZ-3B 24NA
2 x MSZ-GE06 N A
1 x MSZ-GE12 N A
17.5
9.3
For more details on all ENERGY STAR
and tax credit systems go to
www.mitsubishicomfort.com/taxcredit
See page 25 for additional info on efficiency.
LIMITED WARRANTY | Seven-year warranty on compressor. Five-year warranty on parts.
21
mxz-8b48na: the ultimate zoning solution
The Mitsubishi Electric MXZ-8B48NA eight-zone unit. As a
member of the expanding MXZ-B Series of multi-zone systems,
the MXZ-8B outdoor unit incorporates branch boxes to connect
up to eight indoor units.
The INVERTER-driven compressor at the heart of the MXZ-8B
outdoor unit provides variable capacity control, allowing the
system to adjust to the specific demands of the interior space
as needed, not the hard start and stop of a traditional system
installed in most U.S. homes.
M XZ- 8B 48N A ( 2: 1 - 8: 1)
O ut door Un i t
The MXZ-8B48NA has only one port on the outdoor unit for two
insulated refrigerant lines, which run into the home or business
to connect to a branch box or boxes. From the, branch box(es),
gas, and liquid refrigerant piping run to each of the indoor units.
The LEV in the branch box(es) controls the refrigerant flow as the
load of each zone changes.
Through the branch box(es) (the PAC-AKA31BC three-port and/or
the PAC-AKA51BC five-port), the system can connect from two
indoor units up to eight indoor units, depending on application
requirements.
The flexibility of the system doesn’t stop there. The MXZ-8B48NA
has rated capacities of 48,000 Btu/h for cooling and 54,000
Btu/h for heating. System operation, however, can range from a
minimum 12,000 Btu/h to a maximum 54,000 Btu/h in cooling and
a maximum of 60,000 Btu/h in heating. This type of performance
supports a large variety of applications.
The MXZ-8B48NA allows for further flexibility because it supports
a connected indoor unit capacity from 22% to 130% or 12,000
Btu/h to a maximum 70,200 Btu/h, depending on diversity.
Connectable Indoor Units:
General Features:
• Four-ton outdoor unit can support up to
eight indoor units using branch boxes
• Wide variety of indoor unit styles,
including wall-mounted, floor-standing, MSZ-FE09, 12, 18NA
MSZ-GE06, 09, 12, 15, 18, 24NA
ceiling-cassette, ducted
• Individual control up to eight (8) zones
using wired or wireless controls
• Advanced microprocessor control
• Auto restart following a power outage
PEAD-A24AA
• Self-check function offering
SEZ-KD09, 12, 15, 18NA
integrated diagnostics
• Limited warranty: five years on parts and
defects and seven years on compressors
SLZ-KA09, 12, 15NA
22
LIMITED WARRANTY | Seven-year warranty on compressor. Five-year warranty on parts.
MFZ-KA09, 12, 18NA
Multi-room MXZ-B INVERTER heat pump
Model Name
Cooling *1
Non-ducted/
Ducted
Indoor Unit
Heating at
47° F *2 Nonducted/Ducted
Heating at
17° F *3 Nonducted/Ducted
MXZ-8B48NA
Btu/h
Rated Total Input
W
Maximum Capacity
Btu/h
54,000
Rated Capacity
Btu/h
54,000 / 54,000
Rated Total Input
W
Maximum Capacity
Btu/h
60,000
Rated Capacity
Btu/h
33,000 / 34,700
Rated Total Input
W
Maximum Capacity
Btu/h
5,780 / 6,470
2,950 / 3,390
36,600 / 36,550
1 Phase, 60Hz, 208 / 230V
Indoor - Outdoor S1 - S2
AC 208-230V
Indoor - Outdoor S2 - S3
MCA
Recommended Fuse/Breaker
Size
Fan Motor
Compressor
Airflow (Cooling/Heating)
Refrigerant Control
Sound Pressure Level at
Cooling *1
Outdoor Unit
Sound Pressure Level at
Heating *2
DC12-24V
A
32
50
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
2.9
3,530
54
dB(A)
55
Munsell No. 3Y 7.8 / 1.1
37-7/16
13+1-3/16
Weight
Total Capacity 22-130%
H: In.
Lbs.
Btu/h
53-3/16
278
12,000 - 70,200
6,00 - 24,000 / 2-8
Associated with
Indoor Unit Model
R410A
Type
Refrigerant
Refrigerant Pipe
Refrigerant Pipe Length
Charge
Lbs., Oz.
Oil
Type (fl. oz.)
Gas Side O.D.
In.
5/8
In.
3/8
Height Difference (Max.)
Ft.
66/98 *4
Ft.
230
Ft.
49
Ft.
197*
Ft.
180
Total Length (Max.)
Connection Method
18, 11.2
FV50S (73)
Liquid Side O.D.
Maximum Distance between
(Outdoor unit and farthest
indoor unit)
Maximum Pipe Length Branch box to Indoor Unit
Total Maximum line length
between Branch Box and All
Connected Indoor Units
Length from outdoor unit
to branch box (Max.)
Note: Maximum installed capacity is the maximum total
of all connected indoor units, NOT the maximum capacity
produced.
Linear Expansion Valve
dB(A)
D: In.
Type
Specifications are subject to change without notice.
0.086 + 0.086
W: In.
Model / Quantity
Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C),
W.B. 75º F (24º C).
Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C),
W.B. 43º F (6º C).
Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8º C),
W.B. 15º F (-9º C).
66' applies to installations when the outdoor unit is
installed below the indoor unit.
Power factor equals 97 percent.
DC INVERTER-driven Scroll
Dimensions
Remote Controller
*1.
*2.
*3.
*4.
Propeller x 2
External Finish Color
Indoor Unit
NOTES: Test conditions are based on AHRI 210/240. One
indoor unit is turned off during low-speed testing under the
new test conditions.
Systems actually exhibit higher energy efficiencies
during normal operation.
4,820 / 5,270
Phase, Cycle, Voltage
Voltage
*Compatible with the MSZ-A, MSZ-FD, MSZ-FE, MSZ-GE,
MFZ-KA, SEZ-KD, PLA, and PEAD series indoor units
48,000 / 48,000
Multi-Zone Specifications
Power Supply
Outdoor Unit
Rated Capacity
Only a single Lineset is needed
from the outdoor unit to branch box.
See page 25 for MXZ-B information on efficiency
Ft.
377
Indoor/Outdoor
Flared/Flared
*Includes both branch boxes if there are two.
Branch Boxes:
(At least one branch box required)
Required Branch Boxes for MXZ-8B48NA (Maximum of 2 branch boxes can
be connected to one outdoor unit; requires joint MSDD-50AR-E or MSDD-50BR-E.)
Model Name
Connectable No. of Indoor Units
Power Supply
Phase, Cycle, Voltage
PAC-AKA51BC
3
5
1 Phase, 60Hz, 208 / 230V
Power Input
W
3
Current
A
0.05
External Finish
PAC-AKA51BC Branch Box
PAC-AKA31BC
Dimensions
Galvanized-Steel Sheets
Width
In.
Depth
In.
11
Height
In.
7-3/4
Net Weight
Refrigerant Pipe
Dimensions
Lbs.
17-3/4
19
Outdoor Unit to Gas (In.)
Branch Box
Liquid (In.)
Branch Box to
Indoor Units
Drainpipe Size (O.D.)
21
5/8
3/8
Gas (In.)
A,B,C: 3/8
Liquid (In.)
A,B,C: 1/4
In.
A,B,C,D: 3/8; E: 1/2
A,B,C,D,E: 1/4
3/4
PAC-AKA31BC Branch Box
LIMITED WARRANTY | Seven-year warranty on compressor. Five-year warranty on parts.
23
MSZ WALL-MOUNTED INDOOR UNITS
( FOR M XZ-B O UTDO OR UNI TS )
(MSZ-GE12NA Model Shown)
Model Name
Indoor Unit
MSZ-GE06NA MSZ-GE09NA MSZ-FE09NA MSZ-GE12NA MSZ-FE12NA MSZ-GE15NA MSZ-GE18NA MSZ-FE18NA MSZ-GE24NA
Cooling *1
Rated Capacity
Btu/h
Heating at 47°
Rated Capacity
Btu/h
F *2
Power Supply Phase, Cycle, Voltage
Indoor - Outdoor S1 - S2
Indoor - Outdoor S2 - S3
Voltage
Indoor - Remote Controller
MCA
A
Fan Motor
F.L.A.
Airflow at Cooling
(Quiet-Lo-Med-HiSuper Hi or Lo-MedHi-Powerful)*1
Fan
Airflow at Heating
(Quiet-Lo-Med-HiSuper Hi or Lo-MedHi-Powerful) *2
Sound Pressure Level at Cooling
(Quiet-Lo-Med-Hi-Super Hi or LoMed-Hi-Powerful) *1
Sound Pressure Level at Heating
(Quiet-Lo-Med-Hi-Super Hi or LoMed-Hi-Powerful) *2
External Finish Color
Dimension Unit
Weight Unit
Field Drainpipe Size O.D.
Remote ConType
troller
Refrigerant
Type
Gas Side O.D.
Refrigerant
Pipe
Liquid Side O.D.
Connection
Method
6,000
9,000
9,000
12,000
12,000
14,000
17,200
18,000
22,500
7,200
10,900
10,900
14,400
13,600
18,000
21,600
21,600
27,600
388-469628-738
388-469628-738
347-420562-661
347-420562-661
388-469628-738
388-469628-738
DRY
(CFM)
145-170-237-321-399
WET
(CFM)
109-134-201-286-364
WET
(CFM)
145-170233-321406
145-170237-321406
1-phase, 60Hz, 208 / 230V *3
AC 208 / 230V
DC12-24V
Wireless Type (Optional Wired Controller: DC 12V)
1.0
0.76
205-272230-275145-170162-226162-226335-420339-420237-321339-381
381-410
399
533
533
170-237194-240109-134144-202144-202300-385304-385201-286307-343
350-367
364
498
498
166-240367-381
145-170237-321406
166-240399-420
205-247304-367463
230-275339-431512
dB(A)
19-22-30-37-43
22-31-39-42
19-22-3037-45
22-33-43-45
26-32-3844-49
28-33-3844-49
34-41-49-53 34-41-49-53
dB(A)
19-22-30-37-43
22-31-40-42
19-22-3037-43
22-23-43-44
26-30-3540-46
28-33-3843-48
32-41-49-52 32-41-49-52
W: In.
D: In.
H: In.
Lbs.
In.
9-1/8
10-1/8
22
27
Munsell No. 1.0Y 9.2 / 0.2
31-7/16
9-1/8
10-1/8
11-5/8
22
27
5/8
9-1/8
22
43-5/16
9-3/8
12-13/16
37
Wireless Remote (Optional Wired Controller)
R410A
In.
In.
3/8
1/2
1/4
Indoor/Outdoor
5/8
3/8
Flared/Flared
*MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units.
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3. Indoor units receive power from outdoor units through field-supplied wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts. For data on specific indoor unit combinations, see page 21.
SEZ DUCTED INDOOR UNIT
( FOR M XZ-B O UTDOOR UNI TS )
Indoor Unit
Outdoor Unit
Model Name
Cooling *1
Rated Capacity
Heating at 47˚ F *2
Power Supply
Rated Capacity
Phase, Cycle, Voltage
Indoor - Outdoor S1-S2
Voltage
Indoor - Outdoor S2-S3
MCA *4
Fan Motor Output
Fan
Airflow (Lo-Med-Hi)
External Static Pressure *3
Sound Pressure Levels (Lo-Med-Hi)
External Finish
Dimension
Weight
Drain Lift Mechanism (Included)
Field Drainpipe Size
Remote Controller
Type
Refrigerant
Type
Gas Side O.D.
Refrigerant Pipe
Liquid Side O.D.
Connection Method
24
SEZ-KD09NA4 SEZ-KD12NA4 SEZ-KD15NA4
For use with all MXZ-Series
Btu/h
9,000
Btu/h
10,900
A
W
CFM
In. W.G.
dB(A)
W: In.
D: In.
H: In.
Lbs.
H: In.
In.
In.
12,000
15,000
17,200
13,600
18,000
1-Phase, 60Hz, 208 / 230V *4
AC 208-230V
DC24V
1.0
96
247-317-388
353-441-529
0.02-0.06-0.14-0.20
23-28-33
30-34-37
Galvanized-steel Sheets
39
27-9/16
7-7/8
46
51
21-11/16
O.D.: 1-1/4
Wired Controller (PAR-21MAA)
R410A
194-247-317
23-26-30
31-1/8
40
3/8
21,600
Notes:
*1. Cooling-Indoor: D.B. 80º F (26.7º C),
W.B. 67º F (19.4º C); Outdoor: D.B. 95º F
(35º C), W.B. 75º F (23.9º C).
*2. Heating-Indoor: D.B. 70º F (21.1º C),
W.B. 60º F (15.6º C); Outdoor: D.B. 47º F
(8.3º C), W.B. 43º F (6.1º C).
423-529-635
30-34-38
46-7/8
*3. External static pressure is factory
set to 0.06" W.G. Adjustable via the
PAR-21MAA.
*4. Indoor units receive power
from outdoor units through field
supplied interconnected wiring.
Specifications are subject to change
without notice.
60
LIMITED WARRANTY Seven-year
warranty on compressor. Five-year
warranty on parts.
**For data on specific indoor unit
combinations, see page 21 - 23.
1/2
1/4
Flared/Flared
SEZ-KD18NA4
- Reference page 17 for SEZ static
performance curves.
MFZ Floor /low wall INDOOR UNIT
( FO R M XZ-B OUTDOOR UNI TS )
Indoor Unit
Outdoor Unit
Model Name
MFZ-KA09NA
MFZ-KA12NA
MFZ-KA18NA
12,000
18,000
Cooling *1
Rated Capacity
Btu/h
9,000
Heating at 47° F *2
Power Supply
Rated Capacity
Phase, Cycle, Voltage
Indoor - Outdoor S1 - S2
Indoor - Outdoor S2 - S3
Indoor - Remote Controller
MCA
Btu/h
10,900
Voltage
Fan
Airflow at Heating
(Lo-Med-Hi-Super Hi) *2
Sound Pressure Level at Cooling
(Lo-Med-Hi-Super Hi) *1
Sound Pressure Level at Heating
(Lo-Med-Hi-Super Hi) *2
External Finish Color
Weight Unit
Field Drainpipe Size O.D.
Remote Controller
Type
Refrigerant
Type
Gas Side O.D.
Refrigerant Pipe
Liquid Side O.D.
Connection Method Indoor/Outdoor
177-215-261-321
251-279-325-394
163-197-241-303
170-207-252-309
241-269-313-379
(CFM)
177-198-219-332
184-201-219-335
261-275-297-434
dB(A)
25-30-35-40
26-31-36-41
35-38-42-46
dB(A)
25-30-35-40
28-31-36-41
35-38-42-47
In.
In.
sLZ Ceiling-recessed
INDOOR UNIT
Cooling *1
Heating at 47°
F *2
Power Supply
Indoor Unit
SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA
Rated Capacity
Btu/h
8,400
11,100
15,000
Rated Capacity
Btu/h
10,900
13,600
18,000
Phase, Cycle, Voltage
1-phase, 60Hz, 208 / 230V *3
Indoor - Outdoor S1
AC 208 / 230V
- S2
Indoor - Outdoor S2
Voltage
DC12-24V
- S3
MCA
A
1
Fan Motor
F.L.A.
0.23
0.28
0.28
DRY
280-320-350 280-320-390 280-320-390
Fan
Airflow (Lo-Med- (CFM)
Hi)
WET
250-290-320 250-290-350 250-290-350
(CFM)
Sound Pressure Level
dB(A) 25-30-35-40 26-31-36-41 35-38-42-46
Sound Pressure Level at Heating
dB(A)
29-32-38
30-34-39
31-35-40
(Quiet-Lo-Med-Hi-Super Hi) *2
Unit/ Galvanized-steel Sheets/Munsell 6.4Y 8.9
External Finish Color
Grille
/ 0.4
W: In.
22-7/16
Dimension Unit
D: In.
22-7/16
H: In.
8-3/16
Weight Unit
Lbs.
36
Field Drainpipe Size O.D.
In.
1-1/4
Refrigerant
Type
R410
Gas Side O.D.
In.
3/8
1/2
Refrigerant Pipe
Liquid Side O.D. In.
1/4
Connection
Indoor/Outdoor
Flared/Flared
Method
Notes:
*1. Cooling-Indoor: D.B. 80º F (26.7º C), W.B. 67º F (19.4º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (23.9º C).
*2. Heating-Indoor: D.B. 70º F (21.1º C), W.B. 60º F (15.6º C); Outdoor: D.B. 47º F (8.3º C), W.B. 43º F (6.1º C).
*3. Indoor units receive power from outdoor units through field supplied interconnected wiring.
Specifications are subject to change without notice.
*3. Indoor units receive power
from outdoor units through field
supplied interconnected wiring.
Specifications are subject to change
without notice.
LIMITED WARRANTY Seven-year
warranty on compressor. Five-year
warranty on parts.
Presently there is no 1:1 system with
the MFZ indoor unit.
Munsell No. 1.0Y 9.2/0.2
27-9/16
7-7/8
23-5/8
32
5/8
Wireless Remote (optional wired controller)
R410A
3/8
1/2
1/4
Flared/Flared
Efficiency Ratings
( F OR MXZ- B O UTDO OR UNI TS)
Model Name
Notes:
*1. Cooling-Indoor: D.B. 80º F (26.7º C),
W.B. 67º F (19.4º C); Outdoor: D.B. 95º F
(35º C), W.B. 75º F (23.9º C).
*2. Heating-Indoor: D.B. 70º F (21.1º C),
W.B. 60º F (15.6º C); Outdoor: D.B. 47º F
(8.3º C), W.B. 43º F (6.1º C).
169-205-251-314
W: In.
D: In.
H: In.
Lbs.
In.
Dimension Unit
21,600
Mode l
Indoor Unit Ty pe
SEER
HS P F
M XZ-2B20N A-1
N o n-ducted
18
8.9
Ducted and N o n-duc ted
16.75
8.7
Ducted
15.5
8.5
2 x M SZ-GE09N A
18
8.9
N o n-ducted
17.5
9.3
Ducted and N o n-ducted
16.25
8.9
Ducted
15.0
8.5
M XZ-3B24N A
EN ERGY STAR &
TAX C REDIT
2 x M SZ-GE06N A
1 x M SZ-GE09N A
17.5
9.3
M XZ-3B24N A
EN ERGY STAR &
TAX C REDIT
2 x M SZ-GE06N A
1 x M SZ-GE12N A
17.5
9.3
N o n-ducted
17.5
10.5
M XZ-3B30N A
Ducted and N o n-duc ted
16
10.0
Ducted
14.5
9.5
M XZ-2B20N A-1
EN ERGY STAR &
TAX C REDIT
M XZ-3B24N A
M XZ-4B36N A
M XZ-8B48N A
N o n-ducted
18
9.3
Ducted and N o n-ducted
16.5
9.2
Ducted
15.0
9.0
N o n-ducted
15
8.7
Ducted and N o n-duc ted
14.8
8.8
Ducted
14.7
8.9
LIMITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts.
25
Multi-Zone Specifications
Airflow at Cooling
(Lo-Med-Hi-Super Hi)*1
A
DRY
(CFM)
WET
(CFM)
14,400
1-phase, 60Hz, 208 / 230V *3
AC 208 / 230V
DC12-24V
Wireless Type
1
M-Series RATING CONDITIONS
REFRIGERANT LINE LENGTH FLARE/FLARE
Indoor Intake
Air Temperature
Outdoor Intake
Air Temperature
Indoor Unit
Maximum
95°F D.B., 71°F W.B. (MU, SUZ,
MXZ-2B20-1,3B24,3B30,4B36)
90°F D.B., 73°F W.B. (MUZ/Y-GE,
MUZ-FE, MUZ/Y-D)
115°F D.B. (MU, MUZ/Y-GE,
MUZ/Y-D, MUZ-FE, SUZ; MXZ-2B20-1,
3B24, 3B30,4B36,8B48)
Minimum
67°F D.B., 57°F W.B. (MU, MUZ/Y-GE,
MUZ/Y-D, MUZ-FE, SUZ;
MXZ-2B201,3B24,3B30,4B36)
14°F D.B. (MUZ/Y-GE, MUZ/Y-D, MUZ-FE,
SUZ; MXZ-2B20-1,3B24, 3B30,4B36)
23°F D.B. (MXZ-8B48)
67°F D.B. (MU)
Maximum
80°F D.B., 67°F W.B. (MU, MUZ/Y-GE,
MUZ/Y-D, MUZ-FE, SUZ; MXZ-2B20-1,
3B24,3B30,4B36)
75°F D.B., 65°F W.B. (MUZ/Y-GE,
MUZ-FE, SUZ; MXZ-2B20-1,3B24,3B30,4B36)
70°F D.B. (MXZ-8B48)
70°F D.B., 60°F W.B. (MUZ-GE,
MUZ-D, MUZ-FE, SUZ; MXZ-2B201,3B24,3B30,4B36)
-13°F D.B., -15°F W.B. (MUZ-FE)
-4°F D.B., -5°F W.B. (SUZ, MUZ-GE)
5°F D.B., 4°F W.B. (MXZ-8B48NA)
6°F D.B., 5°F W.B. (MXZ-2B20-1,3B24,
3B30,4B36)
14°F D.B., 13°F W.B. (MUZ-D)
Cooling
Heating
Minimum
* MU units operate at intake air temperature down to 10º F with the addition of an ICM-326HM-1 low temperature control.
REFRIGERANT TUBING SETS
Lineset
Model Number
Tube Length
Insul.
Size (In.) Ft.
Use With Mitsubishi
Electric Models
MLS143812T-15
1/4 x 3/8
15
1/2"
MLS143812T-30
1/4 x 3/8
30
1/2"
MLS143812T-50
1/4 x 3/8
50
1/2"
MLS143812T-65
1/4 x 3/8
65
1/2"
MLS141212T-15
1/4 x 1/2
15
1/2"
MLS141212T-30
1/4 x 1/2
30
1/2"
MLS141212T-50
1/4 x 1/2
50
1/2"
MLS141212T-65
1/4 x 1/2
65
1/2"
MLS141212-100
1/4 x 1/2
100
1/2"
MPLS385812T-10
3/8 x 5/8
10
1/2"
MPLS385812T-15
3/8 x 5/8
15
1/2"
MPLS385812T-30
3/8 x 5/8
30
1/2"
MPLS385812T-50
3/8 x 5/8
50
MSY/Z-GE24NA,
MSY/Z-D30,36NA; MXZ-8B48NA,
1/2"
MSZ-FE18NA
MPLS385812T-65
3/8 x 5/8
65
1/2"
MPLS385812T-100
3/8 x 5/8
100
1/2"
MS-A09WA; MSZ-GE06NA;
MSY/Z-GE09,12NA;
MSZ-FE09,12NA;
SEZ-KD09,12NA;
MFZ-KA09,12NA
SLZ-KA09, 12
MS-A12WA; MSY/Z-GE15,18NA;
SEZ-KD15,18NA;
MFZ-KA18NA; SLZ-KA15NA
MS-A09WA
MS-A12WA
MSY-GE09NA
MSY-GE12NA
MSY-GE15NA
MSY-GE18NA
MSZ-GE09NA
MSZ-GE12NA
MSZ-GE15NA
MSZ-GE18NA
MSY-GE24NA
MSZ-GE24NA
MSY-D30NA
MSZ-D30NA
MSY-D36NA
MSZ-D36NA
MSZ-FE09NA
MSZ-FE12NA
MSZ-GE06,09,12,15NA;
MSZ-FE09,12NA;
MFZ-KA09,12NA;
SEZ-KD09,12,15NA
MSZ-GE06,09,12,15,18NA;
MSZ-FE09,12, 18N;
MFZ-KA09,12,18NA;
SEZ-KD09,12,15,18NA
SLZ-KA09, 12, 15NA
Outdoor Unit
Length Height
in feet in feet
MU-A09WA
MU-A12WA
MUY-GE09NA
MUY-GE12NA
MUY-GE15NA
MUY-GE18NA
MUZ-GE09NA
MUZ-GE12NA
MUZ-GE15NA
MUZ-GE18NA
MUY-GE24NA
MUZ-GE24NA
MUY-D30NA
MUZ-D30NA
MUY-D36NA
MUZ-D36NA
MUZ-FE09NA
MUZ-FE12NA
65
65
65
65
65
100
65
65
65
100
100
100
100
100
100
100
65
65
35
35
40
40
40
50
40
40
40
50
50
50
50
50
50
50
40
40
MXZ-2B20NA-1
164
49*/33
MXZ-3B24NA
230
49*/33
MSZ-GE06,09,12,15,18NA;
MSZ-GA24NA,
MSZ-FE09,12, 18NA;
MFZ-KA09,12,18NA;
SEZ-KD09,12,15,18NA
SLZ-KA09, 12, 15NA
MXZ-3B30NA
230
49*/33
MSZ-GE06,09,12,15,18NA;
MSZ-GE24NA,
MSZ-FE09,12, 18NA;
MFZ-KA09,12,18NA;
SEZ-KD09,12,15,18NA
SLZ-KA09, 12, 15NA
MXZ-4B36NA
230
49*/33
MSZ-GE06,09,12,15,18NA;
MSZ-GE24NA,
MSZ-FE09,12, 18NA;
MFZ-KA09,12,18NA;
SEZ-KD09,12,15,18NA
SLZ-KA09, 12, 15NA
MXZ-8B48NA
377
66*/98
OPTIONAL ACCESSORIES
RCMKP1CB
ULTRILITE1
PART NUMBER
M-Series Wireless
All M-Series
MAC-A454JP-E
MAC-A455JP-E
MAC-A456JP-E
MSDD-50AR-E
MSDD-50BR-E
PAC-493PI
PAC-SG76RJ-E
MXZ-Series
MXZ-Series
MXZ-Series
MXZ-Series Branch Box
MXZ-Series Branch Box
MXZ-Series
MXZ-Series
USE WITH
Lockdown bracket for remote controller
Condensing unit mounting pad: 16" x 36" x 3"
DESCRIPTION
Port Adapters and Connection Pipes
Adapter: 3/8" X 1/2"
Adapter: 1/2" X 3/8"
Adapter: 1/2" X 5/8"
Tee Distribution Pipe - Flare Connection between two branch boxes
Tee Distribution Pipe - Braze Connection between two branch boxes
Adapter: 1/4" X 3/8"
Adapter: 3/8" X 5/8"
OPTIONAL ACCESSORIES Continued on next page
26
*49' & 66' applies to installations in which the outdoor unit is installed below indoor unit.
OPTIONAL ACCESSORIES (continued)
PART NUMBER
USE WITH
DESCRIPTION
Control Options and Accessories
Remote temperature sensor for M-Series indoor units
MA and contact terminal interface - Required to use PAR-21MAA wired, wall mount controller
with M-Series Systems
M21 JKO 307
M-Series Indoor Units
MAC-397IF-E
M-Series INVERTER Units
MAC-399IF-E
M-Series INVERTER Units
CMCN M-NET control adapter / Interface for Mr. Slim M-Series MSY/Z, SEZ / MFZ
PAC-YU25HT
SEZ-KD Indoor Units
Use with P-Series, SLZ, SEZ and for wired
M-Series Controller
External Fan / Heater control relay adapter
PAR-FL32MA
SEZ
Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)
PAR-SA9CA-E
SEZ
Wireless signal receiver for SEZ
TAZ-MS303
M-Series
3-pole disconnect switch; 30A, 600V; turns off power between indoor and outdoor units mounts in 2 X 4 utility box and requires standard single gang switch plate/cover
DPLS1
All Indoor Units
Drain Pan Level Sensor/Control
ICM-326HM-2
MAC-641BH-U
M-Series Non-INVERTER units
MUZ-GE09/12/15, MUZ-FE09/12, SUZ-KD09/12/15
outdoor unit
MUZ-GE18, SUZ-KD18 outdoor unit
MAC-1415FT-E
MAC-2300FT-E
MAC-308FT
MAC-408FT-E
MAC-415FT-E
MAC-418FT
MSZ/MSY-D30/36
MSY/MSZ-GA24
MSZ-FD9/12 / FE09/12
M-Series Indoor Unit - GE09/GE12/GE15/GE18
MFZ-KA
MSZ- FD9/12 / FE09/12
FBL1-1
FB Series Filter Box for SEZ-KD09NA
FB Series Filter Box for SEZ-KD12/15NA,
and PEA-A12AA
PAR-21MAA-G
MAC-640BH-U
FBL1-2
FBL1-3
FB Series Filter Box for SEZ-KD18NA
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSY/Z, MFZ)
Low Ambient
Low ambient head pressure controller
Drain pan heater
Drain pan heater
Filters
Anti-allergy enzyme filter
Anti-allergy enzyme filter
Platinum deodorizing filter
Anti-allergy enzyme filter
Air Cleaning Filter/Anti-Allergy Enzyme Filter
Anti-allergy enzyme filter
Filter Boxes
Optional filter box with MERV 8 filters
Optional filter box with MERV 8 filters
Optional filter box with MERV 8 filters
Pumps
SI1730-230
MSY/Z - 30,000 Btu/h or greater
Sauermann mini condensation pump: 230V
SI3100-115
MS-Series - non-INVERTER
Sauermann mini condensation pump: 115V
SI3100-230
MSY/Z - Less than 30,000 Btu/h
Sauermann mini condensation pump: 230V
BRP-1
Bottom Return Plate for SEZ-KD09NA
Miscellaneous
Converts low profile ducted indoor unit from rear return to bottom return
BRP-2
Bottom Return Plate for SEZ-KD12,KD15-NA
Converts low profile ducted indoor unit from rear return to bottom return
BRP-3
BV12FSI
BV14FSI
BV38FSI
BV58FSI
Bottom Return Plate for SEZ-KD18NA
Use with any Mr. Slim multi-zone product
Use with any Mr. Slim multi-zone product
Use with any Mr. Slim multi-zone product
Use with any Mr. Slim multi-zone product
Converts low profile ducted indoor unit from rear return to bottom return
Refrigeration Ball Valve-Flare/Schrader®/Insulated - 1/2"
Refrigeration Ball Valve-Flare/Schrader/Insulated - 1/4"
Refrigeration Ball Valve-Flare/Schrader/Insulated - 3/8"
Refrigeration Ball Valve-Flare/Schrader/Insulated - 5/8"
CWMB1
MU and PU outdoor units
Condensing unit wall mounting brackets (set of 2) - 440 lb. capacity: painted steel NOTE:
Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N
DiamondBack™ Platform Stands
MAC-851DS
MAC-855SG
MAC-856SG
MAC-860DS
MAC-889SG
MAC-899SG
M-Series
MUZ-GE18 / MUZ(Y)-D30/36 /
SUZ-KA18
MUZ-FD09/12
M-Series
M-Series
MUZ-GE09/12/15 / MUZ-FE09/12
M-Series
M-Series
PAC-SG59SG-E
MXZ-8B48NA
Air outlet guide (1 piece) / MXZ-8B48NA (Requires 2 pieces)
PAC-SG61DS-E
PAC-SG64DP-E
MXZ-8B48NA
MXZ-8B48NA
Drain socket - connector
Drain pan
MAC-811DS
Drain socket assembly
Drain socket
Air outlet guide
Air outlet guide - MXZ-3B24 / 3B30 / 4B36 NA
Drain socket
Air outlet guide- MXZ-2B20NA
Air outlet guide
27
MXZ-B Series Port Adapter chart
Port Adapter
Required
Unit Port
Size
2-zone combinations w/
both units ≤12K
N/A
A: 3/8" x
1/4"
6+15
1-MAC-A454JP-E
B: 3/8" x
1/4"
9+15
1-MAC-A454JP-E
Combinations
MXZ-2B20NA-1
Combinations
Qty.
With 3-Port
Branch Box
Qty.
With 5-Port
Branch Box
2-zone combinations w/ both units ≤12K
-
N/A
-
N/A
2-zone combinations w/ one unit ≥15K
1
1-MAC-A454JP-E
-
N/A
2-zone combinations w/ both units ≥12K
2
1-MAC-A454JP-E
1
1-MAC-A454JP-E
6+24, 9+24 or 12+24
1
1-PAC-SG76RJ-E
1
1-PAC-SG76RJ-E
1
1-PAC-SG76RJ-E
2
1-PAC-SG76RJ-E
MXZ-8B48NA
MXZ-3B24NA
All rated 2-zone combinations
N/A
A: 1/2" x
1/4"
15+24 or 18+24
All rated 3-zone combinations
N/A
B: 3/8" x
1/4"
24+24
C: 3/8" x
1/4"
MXZ-3B30NA
2-zone combinations w/ at
least one unit ≤12K
N/A
A: 1/2" x
1/4"
2-zone combinations w/
both units ≥15K
1-MAC-A454JP-E
B: 3/8" x
1/4"
9 + 24
1-MAC-A456JP-E
C: 3/8" x
1/4"
3-zone combinations w/
all units ≤12K
1-MAC-A455JP-E
All other rated 3-zone
comb.
N/A
A: 1/2" x
1/4"
2-zone combinations w/
both units ≥15K
1-MAC-A454JP-E
B: 3/8" x
1/4"
6 + 24
1-MAC-A456JP-E
C: 3/8" x
1/4"
9 + 24
1-MAC-A456JP-E
D: 3/8" x
1/4"
3-zone combinations w/ at
least two units ≤12K
N/A
3-zone combinations w/
two units ≥15K
1-MAC-A454JP-E
6+6+24 or 6+9+24
1-MAC-A456JP-E
9+9+24
1-MAC-A456JP-E
4-zone combinations w/ at
least three units ≤12K
1-MAC-A455JP-E
6+6+15+15
1-MAC-A454JP-E
6+6+15+15
1-MAC-A454JP-E
Note: When using the PLA-A24BA, PCA-A24KA, or PEAD-A24AA two port
adapter will be needed: 1-MAC-A456JP-E (1/2" x 5/8") A port or 1-PACSG76RJ-E (3/8" x 5/8") B, C, and D ports, and 1-PAC493PI (1/4" x 3/8")
1-PAC-SG76RJ-E
2
1-PAC-SG76RJ-E
-
N/A
1
N/A
1
1-MAC-A454JP-E
1
N/A
3-zone combinations w/ two units ≥15K
2
1-MAC-A454JP-E
1
1-MAC-A454JP-E
3-zone combinations w/ all units ≥15K
3
1-MAC-A454JP-E
2
1-MAC-A454JP-E
6+6+24, 6+9+24, 6+12+24, 9+9+24,
9+12+24 or 12+12+24
1
1-PAC-SG76RJ-E
1
1-PAC-SG76RJ-E
1
1-MAC-A454JP-E
1
1-PAC-SG76RJ-E
1
1-PAC-SG76RJ-E
2
1-MAC-A454JP-E
1
1-MAC-A454JP-E
1
1-PAC-SG76RJ-E
1
1-PAC-SG76RJ-E
2
1-PAC-SG76RJ-E
2
1-PAC-SG76RJ-E
1
1-MAC-A454JP-E
2
1-PAC-SG76RJ-E
2
1-PAC-SG76RJ-E
1
See notes for
application below
1
See notes for
application below
6+15+24, 6+18+24, 9+15+24, 9+18+24,
12+15+24 or 12+18+24
15+24+24 or 18+24+24
2-zone combinations w/ at
least one unit ≤12K
1-MAC-A454JP-E
3-zone combinations w/ two units ≤12K
6+24+24, 9+24+24 or 12+24+24
N/A
1
1
3-zone combinations w/ all units ≤12K
15+15+24, 15+18+24 or 18+18+24
MXZ-4B36NA
28
Port Adapter Required
Combinations of 4 or more zones
Available Indoor Units
MXZ-8B48NA
Branch Box
Branch Box
PAC-AKA31BC
PAC-AKA51BC
PORT A = 3/8" gas x
1/4" liquid
PORT A = 3/8" gas x
1/4" liquid
PORT B = 3/8" gas x
1/4" liquid
PORT B = 3/8" gas x
1/4" liquid
PORT C = 3/8" gas x
1/4" liquid
PORT C = 3/8" gas x
1/4" liquid
Line set size
Wall-Mounted
MSZ-GE06/09/12NA
3/8" gas x 1/4" liquid
MSZ-GE15/18NA
1/2" gas x 1/4" liquid
MSZ-GE-24NA
5/8" gas x 3/8" liquid
MSZ-FE09/12
3/8" gas x 1/4" liquid
MSZ-FE18NA
5/8" gas x 3/8" liquid
Floor-Standing
PORT D = 3/8" gas x
1/4" liquid
MFZ-KA09/12NA
3/8" gas x 1/4" liquid
PORT E = 1/2" gas x
1/4" liquid
MFZ-KA18NA
1/2" gas x 1/4" liquid
PLA Ceiling-Cassette
PLA-A12/18BA
Notes for application:
• Check the lineset sizes for your indoor
PLA-A24BA
selected models.
• Select the branch box or boxes needed
Horizontal Ducted
for your application.
SEZ-KD09/12NA
• Compare indoor unit lineset sizes as
compared to branch box sizes.
SEZ-KD15/18NA
• Connect 15K + indoor units to the larger port
on the (PAC-AKA51BC).
PEAD-A24AA
• Adapt lineset size with appropriate port adapter
from ‑above list.
• When using the PLA-A24BA or PEAD-A24AA, two port
adapter will be needed: 1-MAC-A456JP-E
(1/2" x 5/8") or 1-PAC-SG76RJ-E (3/8" x 5/8") and 1-PAC493PI (1/4" x 3/8").
1/2" gas x 1/4" liquid
5/8" gas x 3/8" liquid
3/8" gas x 1/4" liquid
1/2" gas x 1/4" liquid
5/8" gas x 3/8" liquid
BV-Series Ball Valves
Model numbers:
BV14FFSI
BV38FFSI
BV12FFSI
BV58FFSI
•
•
•
•
•
•
•
•
•
•
•
C
US
LISTED 891N
REFRIGERANT
VALVE
Size available: 1/4”; 3/8”; 1/2”; 5/8”
Fully factory assembled
Furnace brazed and pressure tested
Each ball valve is equipped with Schrader® Valve
for refrigerant service
Design working pressure: 700 PSIG
Temperature range:
-40˚ F to +325˚ F (-40˚ C to +149˚ C)
Forged brass body and seal cap
Teflon® seals and gaskets (no synthetic O-rings)
Seal cap design permits valve operation without removal of seal cap
Suitable for use with R-11, R-22, R-123, R-125, R-134A, R-236FA, R-4202A, R-402B, R-404A, R-407C, R-410A, R-500, R-502, and R-507
One year limited materials and workmanship
warranty on Ball Valves
• Engineered for Mini-split and
Multi-split HVAC Units
• Full Port Design
• 700 PSIG Rated
• R-410A Compatible
• Flare Connections
Part Number
SAE
Flare
A
B
C
D
E
F
BV14FFSI
1/4”
6.19
2.60
1.80
1.22
1.42
1.10
BV38FFSI
3/8”
6.30
2.67
1.80
1.22
1.42
1.10
BV12FFSI
1/2”
6.51
2.67
1.80
1.22
1.42
1.10
BV58FFSI
5/8”
6.64
2.67
1.80
1.28
1.42
1.10
*Ball valves come with an insulation piece.
Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our
Diamondback Platform Stands.
• Easy to install
• Available for all sizes of Mr. Slim outdoor units
• Color matched to the outdoor units
Model Number: DSD-400N
L: 15-3/4” x W: 3-1/4” x H: 3-1/4”
29
Linesets
Caps on
Caps off with
flared ends
exposed
Lineset
Model Number
Tube
Size (In.)
Length
Ft.
Insul.
MLS143812T-15
MLS143812T-30
MLS143812T-50
MLS143812T-65
MLS141212T-15
MLS141212T-30
MLS141212T-50
MLS141212T-65
MLS141212T-100
1/4 x 3/8
1/4 x 3/8
1/4 x 3/8
1/4 x 3/8
1/4 x 1/2
1/4 x 1/2
1/4 x 1/2
1/4 x 1/2
1/4 x 1/2
15
30
50
65
15
30
50
65
100
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
MLS145812T-15
MLS145812T-30
MLS145812T-50
MLS145812T-65
MLS145812T-100
MPLS385812T-10
MPLS385812T-15
MPLS385812T-30
MPLS385812T-50
1/4 x 5/8
1/4 x 5/8
1/4 x 5/8
1/4 x 5/8
1/4 x 5/8
3/8 x 5/8
3/8 x 5/8
3/8 x 5/8
3/8 x 5/8
15
30
50
65
100
10
15
30
50
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
MPLS385812T-65
3/8 x 5/8
65
1/2"
MPLS385812T-100
3/8 x 5/8
100
1/2"
“Twin-Tube” Lineset Insulation Design
•Balanced outside diameter for uniform coil/uncoil
position stability.
•Minimum 1/2” insulation thickness on both tubes
Diamondback Advantages include the following features:
• Quick, efficient, and economical field installation using factory applied
Twin Tube insulation and flare connections with flare nuts mounted
• Correct lengths for reducing waste and time
• Quality, consistency, and economy
• All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all
Mr. Slim horizontal ducted indoor units.
FBL1-1
FB Series Filter Box for SEZ-KD09NA
FBL1-2
FB Series Filter Box for SEZ-KD12, KD15NA
FBL1 filter boxes include 1" thick pleated MERV 8 filter(s) installed.
Filters are tested in accordance with ANSI/ASHRAE Standard 52.2
and Rated Class 2 under U.L. Standard 900.
FBL1-3
FB Series Filter Box for SEZ-KD18NA
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
steel with foam gasket and provides an air-tight connection to indoor unit and access door. Gasket material
complies with UL 723 requirements.
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily
field-converted to bottom return.
30
Line - Hide
Lineset Cover System
TM
Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets, drainlines, and wiring.
• Can be use it indoors, too! Meets UL94v-0 for
interior applications.
• Has snap-on covers and a full selection of
couplings, elbows, T-joints, caps, and more for any
application, complex or simple.
• Offers high-quality PVC with UV inhibitors for
outdoor service in all weather conditions.
• Can be painted with most house paints to match
exterior decors.
• Is not just for HVAC. Hide any exterior cabling,
piping, or wiring.
• Available in four sizes: 2-1/4”, 3”, 4”, and 6” tubes.
Download a brochure at www.line-hide.com to find
out more information.
For more information on
our CITY MULTI VRF product
line visit our website at
www.mitsubishipro.com
Variable Refrigerant Flow
Zoning Systems: 3-30 Tons
31
Mitsubishi Electric Advanced Products Division
3400 Lawrenceville Suwanee Road, Suwanee, GA 30024
Phone: 888-467-7546 Fax: 800-658-1458
©2011 Mitsubishi Electric & Electronics USA, Inc. Mr Slim and H2i are
registered trademarks of Mitsubishi Electric. The three-diamond logo is a
registered logo of Mitsubishi Electric Corporation.
*Hyper-Heating technology Patent Pending.
See complete warranty for terms, conditions and limitations.
A copy is available from Mitsubishi Electric.
Form No. MSERIES 5-11 50K OA (reprint)
For more information visit www.mitsubishicomfort.com
facebook.com/mehvac
twitter.com/mitsubishihvac
youtube.com/mitsubishihvac
Please Recycle