Castle Euro 76 Series WebWay Alarm Panel Integration
WebWayOne Alarm System integration improves security
and reduces costs
WebWayOne and Castle have integrated the EuroOne with the WebWay
IP/GPRS and WebWay GPRS/PSTN to provide the six essential
elements of a fully managed Alarm System.






Automatic Commissioning
ATS Monitoring and Fault Reporting
Alarm and Fault reporting
Remote Support
Upload/Download
Remote Maintenance
Castle Alarm Systems
The following Castle panels are supported:


EuroOne
EuroOne Plus
Connection is via a serial link or modem capture with the following
required:



WebWayOne Castle cable (05-5031)
EuroOne G2 – MSX-5 Expander card
WebWay Modem Capture Module (22- 5059) required modem
capture for communications
Simple installation and commissioning
The WebWay solution is quick and easy to install and commission with
your chosen ARC. A WebWay modem capture board with a two wire
connection to the Alarm System, (or a WebWay provided cable serial
emulation), a two-wire connection for power, an Ethernet cable to the
Router and locate the aerial.
EuroOne and WebWay SPT
Serial Connectivity
WebWay SPT
RS232 T
RS232 R
RTN
Cable
BLUE
RED
GREEN
Castle Cable
If you are using a Castle supplied cable (Part Ref Euro-055 Loom) and
cutting to fit the cable wiring will be as follows,
WebWay SPT
RS232 T
RS232 R
RTN
Cable
BLUE
YELLOW
BLACK
IMPORTANT – Ensure that the cable is plugged into the expansion
card on the castle panel and not the RS232 port on the main PCB.
Our Auto Take On process completes the WebWay installation. The
WebWay servers automatically programme the WebWay to work
seamlessly with the Castle to enable SIA alarms, Upload Download and
secure remote access using the Castle software.
Automatic SIA 3 with text enriched messages
All alarms generated by the Alarm System are automatically sent to the
AMS using SIA. SIA messages provide a full audit trail of an event which detector, location, time and date, and a permanent record of every
alarm. Messages for set and unset include who, where, time, and date,
all recorded. No need to check that each PIN is correctly wired; the
Castle and the WebWay take care of everything automatically.
1
www.webwayone.co.uk
sales@webwayone.co.uk
01635 231500
Castle Euro 76 Series WebWay Alarm Panel Integration
Serial Panel Programming
1.
Go to Engineering Mode
2.
Go to programme Digi/SMS calls
3.
Select Disable Digi/SMS <0>
4.
Select ARC Details <1>
5.
Select Active <Yes>
6.
Select format <WebWayOne IP> (Option 141)
7.
Select SIA Ack Char <006>
8.
Select SIA Nack Char <021>
9.
Select valid areas <select areas to be reported>
Settings for Remote Management
1.
Go to ‘set up downloading’
2.
Select download by <WebWayOne>
3.
Select poll timeout <10>
4.
Select modem init timeout <060>
5.
Select rings to answer <1>
6.
Select comm. Tx timeout <030>
7.
Select ARMPC telephone number <not required>
8.
Select program PCs <1>
9.
Select modem telephone number <not required>
10. Select stop on success <yes>
10. Select signal alarms <No>
11. Select ARC account <No>
11. Select signal faults <No>
12. Select content 1-16 <Trigger events> (recommend 1-5, & 7-13)
12. Select signal set/unset <No>
13. Select content 17-32 <Trigger events> (recommend 21-25, 27-30, & 32)
14. Select redials <03>
15. Select time out <15>
16. Select test calls <No>
13. Select signal access code <No>
14. Select password <optional UDL password>
15. Select redials <03>
16. Select time out <00>
17. Select stop on success <No>
18. Select dial mode <retry same>
19. Exit engineering mode and save the configuration
2
www.webwayone.co.uk
sales@webwayone.co.uk
01635 231500
Castle Euro 76 Series WebWay Alarm Panel Integration
Modem Capture Connectivity
Connect the A and B ‘PSTN’ terminals and ground on the WebWay to
the A and B telephone connections on the Euro ONE alarm panel.
Connect the WebWay PWR + and - to any relevant Power and Ground
terminals.
Panel Programming
1.
Go to Engineering Mode
2.
Go to programme Digi/SMS calls
3.
Select Disable Digi/SMS <0>
4.
Select ARC Details <1>
5.
Select Active <Yes>
6.
Select format SIA <SIA 3> (Option 129)
7.
Select first number <01666111>
8.
Select first number <01666222>
9.
Select valid areas <select areas to be reported>
Settings for Remote Management
10. Select stop on success <yes>
11.
Select ARC account <No>
12. Select content 1-16 <Trigger events> (recommend 1-5 & 7-13)
13. Select content 17-32 <Trigger events> (recommend 21-25, 27-30 & 32)
14.
Select redials <03>
15.
Select time out <15>
16. Select test calls <No>
1.
Go to ‘set up downloading’
2.
Select download by <modem>
3.
Select security mode <auto-answer>
4.
Select telecom line <dedicated>
5.
Select number of rings <3>
6.
Select modem speed <high>
7.
Select ARMPC telephone number <123456>
8.
Select program PCs <1>
9.
Select modem telephone number <not required>
10. Select signal alarms <No>
11. Select signal faults <No>
12. Select signal set/unset <No>
13. Select signal access code <No>
14. Select password <optional UDL password>
15.
Select redials <03>
16. Select time out <00>
17. Select stop on success <No>
18. Select dial mode <retry same>
19. Exit engineering mode and save the configuration
20. Go to Site Options
21. Select ATE inputs <STU>