Contents
BRIEF INTRODUCTION
03
KIT
09
OUTDOOR STATION
22
INDOOR STATION
28
ACCESSORIES
44
SYSTEM DIAGRAM
52
ACCESS CONTROL SYSTEM
66
BRIEF INTRODUCTION
A BRIEF OUTLINE OF THE CATALOGUE
03 Brief Introduction
Brief Introduction 04
General Catalogue
Brief introduction
Basic elements in audio/video door entry system installation
Which system to use
Outdoor Stations
Genway offers you the following recommendation table:
Choose the style of panel you want...
Depending on the type of building in which you are going to install the system,
GENWAY offers you different styles of outdoor stations...
D5 SHELL
S2 SHELL
S5 SHELL
S6 SHELL
S7 SHELL
For
you can choose……
2-wire system (Video, up to 2 outdoor stations and 4 indoor
stations; Audio, up to 1 outdoor station and 1 indoor station)
E SHELL
E2 SHELL
G9 SHELL
Single family houses
4-wire system (Video only, up to 2 outdoor stations and 4
indoor stations)
5-wire system (Audio only, up to 1 outdoor station and 4
indoor stations)
Small buildings (up to 26 apartments)
Indoor Stations
Choose the indoor stations you want...
H4 SHELL
V12 SHELL
V20 SHELL
V1 SHELL
V3 SHELL
V13 SHELL
Low-rised or high-rised building
05 Brief Introduction
1+N Audio system or 5+N Video system,
up to 26 apartments, 2 out door stations
Classic direct call system
C-5 system (Video, up to 800 apartments,8 outdoor stations, 9
gate stations and 9 guard units)
One cable system
Brief Introduction 06
General Catalogue
Brief introduction
Types Of Systems
2-WIRE SYSTEM
5+N SYSTEM
VIDEO
AUDIO
1+N SYSTEM
VIDEO
AUDIO
5+1
7+1
2
1
1
202
201
7+4
2
2
5+1
1+2
7+1
7+4
1
12V
1
102
2
Power Supply
101
2
2
1+4
2
2
2
2
~AC~
TRANSFORMER
Model:PS-5E
Input:230V 50~60Hz
Output:18V 800mA
2
~AC~
TRANSFORMER
Model:PS-2E
Input:230V 50~60Hz
Output:13.5V 800mA
Notes:Used in indoor
Notes:Used in indoor
+DC-
+DC-
4-WIRE SYSTEM
5-WIRE SYSTEM
VIDEO
C-5 SYSTEM
AUDIO
Non-network
Network
Power
Supply
CAT-5
PORT4
2
PORT3
CAT-5e
PORT1
PORT2
LB VF- VF+ AF- AF+ GND DC+
LA
信息发布模块
型
号:4130S
工作电压:DC30-35V
工作电流:≤90mA
厦门市振威安全技术发展有限公司
4
RJ-45
CAT-5e
CAT-5
CAT-5
LA
信息发布模块
型
号:4130S
工作电压:DC30-35V
工作电流:≤90mA
PORT1
RJ-45
CAT-5
RJ-45
CAT-5
CAT-5
PORT3
PORT2
LB VF- VF+ AF- AF+ GND DC+
PORT1
RJ-45
CAT-5
12V
模块
LA
信息发布模块
PORT1
Power Supply
下载
型
号:4130S
工作电压:DC30-35V
工作电流:≤90mA
CAT-5e
2
CAT-5e
Door station
副Door station
2
模块
12V
Door station
副Door station
厦门市振威安全技术发展有限公司
厦门 市振威 安全技 术发展 有限 公司
型
号:4300
工作电压:DC30-35V
工作电流:≤90mA
型
号:4300
工作电压:DC30-35V
工作电流:≤90mA
可视联网切换器
可视联网切换器
电源
下行
2
LA LB VF- VF+ AF- AF+COM1COM2
DC+ GND PS
上行
LA LB VF- VF+ AF- AF+COM1 COM2
下行
LA LB VF- VF+ AF- AF+COM1COM2
Waterproof CAT-5
CAT-5
4
下载
Power Supply
上行
CAT-5
LA LB VF- VF+ AF- AF+COM1COM2
厦门市振威安全技术发展有限公司
CAT-5e
电源
RJ-45
DC+ GND PS
4
PORT2
LB VF- VF+ AF- AF+ GND DC+
PORT3
PORT4
LA
信息发布模块
CAT-5e
2
型
号:4130S
工作电压:DC30-35V
工作电流:≤90mA
CAT-5
12V
CAT-5e
PORT4
2
厦门市振威安全技术发展有限公司
Power Supply
2
PORT1
PORT2
LB VF- VF+ AF- AF+ GND DC+
LA
信息发布模块
CAT-5
5
型
号:4130S
工作电压:DC30-35V
工作电流:≤90mA
4
厦门市振威安全技术发展有限公司
4
Power
Supply
PORT3
PORT4
CAT-5
厦门市振威安全技术发展有限公司
PORT2
LB VF- VF+ AF- AF+ GND DC+
PORT3
PORT4
2
2
Waterproof CAT-5
Power Supply
12V
CAT-5
PORT4
2
4400 SWITCH
PORT3
1 2 3 4 5
6 7 8 9 10
11 12
A B C D
POWER
USB
UPLINK- PORT1
PORT2 PORT3
PORT4
PORT5 PORT6
PORT7 PORT8
PORT9 PORT10
PORT11 PORT12
DC24-40V
+
PORT1
PORT2
LB VF- VF+ AF- AF+ GND DC+
LA
信息发布模块
型
号:4130S
工作电压:DC30-35V
工作电流:≤90mA
厦门市振威安全技术发展有限公司
4
RJ-45
CAT-5
Waterproof CAT-5
00年0 1月0 1日
星期 一
0 1点3 0分15秒
振 威 , 欢 迎 您!
2
2
Waterproof CAT-5
CAT-5e
07 Brief Introduction
Brief Introduction 08
KIT
DOOR ENTRY KIT FOR SINGLE HOUSE
09 Kit
Kit 10
General Catalogue
Kit
4-wire door entry kit
Budget kit
FEATURES:
B/W HANDSET DOOR ENTRY KIT
Includes
Call, talk and remote unlocking.
Intercom is available between indoor stations.
Double Ding-Dong ring.
Power supply: Adapter, transformer for optional.
CONNECTION DIAGRAM
4
2
Budget kit
FS5V12
FD5V12-N
F5S50 one outdoor station
Aluminum alloy panel
Dimension and installation:refer to page
20”S5 SHELL”
Surface-mounted
Name plate changeable
Adaptor:one switch power supply
AC 100-240V, DC14V, 0.8A
F3120-B one indoor station
Dimension:203×220×63mm
Surface-mounted
B/W 4”screen
Packing box refer to page 18
4013:Transformer type switch
power supply AC 100-240V,
DC14V, 0.8A
B/W HANDSET DOOR ENTRY KIT BUILT-IN POWER SUPPLY
Includes
F5D50 one outdoor station
Aluminum panel
Dimension and installation:refer to page
19”D5 SHELL”
Flush-mounted
Name plate changeable
Packing box refer to page 18
CONNECTION DIAGRAM
Budget kit
FD5V12
4
FS5V20
B/W HANDS-FREE DOOR ENTRY KIT
Includes
F3120-BN one indoor station
Dimension:203×220×63mm
Surface-mounted
B/W 4”screen
With built-in power supply
2
Budget kit
F5S50 one outdoor station
Aluminum alloy panel
Dimension and installation:refer to page
20”S5 SHELL”
Surface-mounted
Name plate changeable
Adaptor:one switch power supply
AC 100-240V, DC14V, 0.8A
F3200-B one indoor station
Dimension:203×220×46mm
Surface-mounted
B/W 4”screen
Packing box refer to page 18
4013: Transformer type switch
power supply AC 100-240V,
DC14V, 0.8A
2
B/W HANDSET DOOR ENTRY KIT
FS5V1
COLOR HANDS-FREE DOOR ENTRY KIT
Includes
F5D50 one outdoor station
Aluminum panel
Dimension and installation:refer to page
19”D5 SHELL”
Flush-mounted
Name plate changeable
F3120-B one indoor station
Dimension:203×220×63mm
Surface-mounted
B/W 4”screen
11 Kit
Adaptor:one switch power
supply AC 100-240V, DC14V,
0.8A
4013: Transformer type switch
power supply AC 100-240V,
DC14V, 0.8A
Packing box refer to page 18
Includes
F5S50-C one outdoor station
Aluminum alloy panel
Dimension and installation:refer to page
20”S5 SHELL”
Surface-mounted
Name plate changeable
F3010 one indoor station
Dimension:220×150×25mm
Surface-mounted
Color 5”TFT
Adaptor:one switch power supply
AC 100-240V, DC14V, 0.8A
4013:Transformer type switch
power supply AC 100-240V,
DC14V, 0.8A
Packing box refer to page 18
Kit 12
General Catalogue
Kit
FS5V11
COLOR HANDS-FREE DOOR ENTRY KIT
Includes
F3110 one indoor station
Dimension:220×208×46mm
Surface-mounted
Color 7”TFT
Adaptor:one switch power supply
AC 100-240V, DC14V, 0.8A
4013: Transformer type switch
power supply AC 100-240V,
DC14V, 0.8A
Packing box refer to page 18
COLOR HANDS-FREE DOOR ENTRY KIT
Includes
F3010 one indoor station
Dimension:220×150×25mm
Surface-mounted
Color 5”TFT
Adaptor:one switch power supply
AC 100-240V, DC14V, 0.8A
4013: Transformer type switch
power supply AC 100-240V,
DC14V, 0.8A
Packing box refer to page 18
COLOR HANDS- FREE DOOR ENTRY KIT
Includes
F5S70-C one outdoor station
Zinc alloy panel
Dimension and installation:refer to page
20”S7 SHELL”
Surface-mounted
F3110 one indoor station
Dimension:220×208×46mm
Surface-mounted
Color 7 ” TFT
13 Kit
F5S70-C one outdoor station
Zinc alloy panel
Dimension and installation:refer to page
20”S7 SHELL”
Surface-mounted
F3030 one indoor station
Dimension:185×120×28mm
Surface-mounted
Color 3.5”TFT
FG9V1
Adaptor:one switch power supply
AC 100-240V, DC14V, 0.8A
4013: Transformer type switch
power supply AC 100-240V,
DC14V, 0.8A
Packing box refer to page 18
COLOR HANDS- FREE DOOR ENTRY KIT
Includes
F5S70-C one outdoor station
Zinc alloy panel
Dimension and installation:refer to page
20”S7 SHELL”
Surface-mounted
FS7V11
COLOR HANDS- FREE DOOR ENTRY KIT
Includes
F5S50-C one outdoor station
Aluminum alloy panel
Dimension and installation:refer to page
20”S5 SHELL”
Surface-mounted
Name plate changeable
FS7V1
FS7V3
F5G91-C one outdoor station
Stainless steel panel
With ID card reader function
Dimension and installation:refer to page
20”G9 SHELL”
Flush-mounted
Adaptor:one switch power supply
AC 100-240V, DC14V, 0.8A
F3010 one indoor station
Dimension:220×150×25mm
Surface-mounted
Color 5”TFT
Packing box refer to page 18
FG9V11
4013: Transformer type switch
power supply AC 100-240V,
DC14V, 0.8A
COLOR HANDS-FREE DOOR ENTRY KIT
Includes
Adaptor:one switch power supply
AC 100-240V, DC14V, 0.8A
4013: Transformer type switch
power supply AC 100-240V,
DC14V, 0.8A
Packing box refer to page 18
F5G91-C one outdoor station
Stainless steel panel
With ID card reader function
Dimension and installation:refer to page
20”G9 SHELL”
Flush-mounted
Adaptor:one switch power supply
AC 100-240V, DC14V, 0.8A
F3110 one indoor station
Dimension:220×208×46mm
Surface-mounted
Color 7”TFT
Packing box refer to page 18
4013:Transformer type switch
power supply AC 100-240V,
DC14V, 0.8A
Kit 14
General Catalogue
Kit
2-WIRE DOOR ENTRY KIT
Australia only
Surface-mounted outdoor station, pin-hole, color camera,hands-free indoor station.
2-wire connection, with call, talk and remote unlocking.
Intercom is available between indoor stations.
Double Ding-Dong ring.
DS4V1
COLOR HANDS- FREE DOOR ENTRY KIT
Includes
7S40-C one outdoor station
Dimension and installation:refer to page
21”S4 SHELL”
Surface-mounted
Adaptor:one switch power supply
AC 100-240V, DC24V, 1.0A
Packing box refer to page 18
7010K one master indoor station
Dimension:220×150×25mm
Surface-mounted
Color 5”TFT
CONNECTION DIAGRAM(Video)
2
DS6V1
2
7010P Subsidiary indoor station(optional)
2
COLOR HANDS- FREE DOOR ENTRY KIT
Australia only
Includes
DS4V13
COLOR HANDS- FREE DOOR ENTRY KIT
Includes
7S60-C one outdoor station
Zinc alloy panel
With pin-hole color camera
Dimension and installation:refer to page
19”S6 SHELL”
Surface-mounted
Name plate changeable
Adaptor:one switch power
supply AC 100-240V, DC24V,
1.0A
Adaptor:one switch power supply
AC 100-240V, DC24V, 1.0A
7S40-C one outdoor station
Dimension and installation:refer to page
21”S4 SHELL”
Surface-mounted
Packing box refer to page 18
Packing box refer to page 18
7130K one master indoor station
Dimension:220×150×27mm
Surface-mounted
Color 7”TFT
7010K one master indoor station
Dimension:220×150×25mm
Surface-mounted
Color 5”TFT
7130P Subsidiary indoor station
7010P Subsidiary indoor station(optional)
DS6V13
COLOR HANDS-FREE DOOR ENTRY KIT
Includes
7S60-C one outdoor station
Zinc alloy panel
With pin-hole color camera
Dimension and installation:refer to page
19”S6 SHELL”
Surface-mounted
Name plate changeable
CONNECTION DIAGRAM(Audio)
Adaptor:one switch power
supply AC 100-240V,DC24V,
1.0A
Packing box refer to page 18
2
2
2
7130K one master indoor station
Dimension:220×150×27mm
Surface-mounted
Color 7”TFT
7130P Subsidiary indoor station(optional)
15 Kit
Kit 16
General Catalogue
Kit
DS2H4
AUDIO HANDSET DOOR ENTRY KIT
PACKING BOX
Includes
D5S20H one outdoor station
Aluminum alloy panel
Dimension and installation:refer to
page21” S2 SHELL”
Surface-mounted
Name plate changeable
Adaptor:one power supply DC
14V 0.2A
Packing box refer to page 18
01A-box
FD5V12
462mm
414mm
FS5V12
FS5V20
262mm
D3H40 one indoor station
Dimension:202×80×67mm
Surface-mounted
With mute function
01B-box
284mm
Mute switch button
FD5V12-N
88mm
01A-box
02A-box
FS5V1
DS6V1
FG9V11
FS5V11
DS6V13
5
2
FS7V1
DS4V1
FS7V3
DS4V13
352mm
FS7V11
110mm
02A-box
Includes
WL-06Dd2 one outdoor station
Aluminum panel
Dimension and installation:refer to page
21”D2 SHELL”
Flush-mounted
Adaptor:one power supply DC
15V 0.8A
03A-box
04A-box
DS2H4
WL-06Dd2D
02B-box
Dimension:
352(L)×88(W)×241(H)mm
316mm
347mm
Packing box refer to page 18
240mm
AUDIO HANDSET DOOR ENTRY KIT
88mm
Dimension:
388(L)×110(W)×352(H)mm
296mm
WL-06Dd2D
Dimension:
414(L)×88(W)×262(H)mm
388mm
02C-box
FG9V1
CONNECTION DIAGRAM
2
02B-box
01B-box
352mm
One outdoor station can connect with four indoor station.
Dual talking between outdoor station and indoor station.
Remote unlock.
88mm
Dimension:
462(L)×88(W)×284(H)mm
241mm
5-WIRE DOOR ENTRY KIT
WL-06DFaD one master indoor station
Dimension:202×80×67mm
Surface-mounted
WL-06DFbD
Subsidiary indoor station(optional)
70mm
88mm
02C-box
Dimension:
316(L)×88(W)×296(H)mm
03A-box
Dimension:
347(L)×70(W)×240(H)mm
215mm
358mm
75mm
04A-box
17 Kit
Dimension:
358(L)×75(W)×215(H)mm
Kit 18
General Catalogue
Kit
S5 SHELL
DOOR STATION INSTALLATION
Unit: mm
45.5
60.5
D5 SHELL
Unit: mm
206
208
108
④
③
①
④
94
④
S7 SHELL
Wall
Change name plate
①
58
201
③
48
③
⑤
Name plate
1.Push the right edge
and move to right.
2.Take off
the plastic.
☆ During installation, put
the wire through the hole
of PC plate, then connect
it with door station terminal,
and glue the PC plate on
the door station rear panel
at last.
④
60
135
Plastic
④
Unit: mm
①
②
②
②
126
Iron door
⑤
92
42
128
38
① Door/Wall
② Door station front
③ Door station bracket
④ Screw
3.Change the
name plate
④
④
① Door/Wall
④ Screw
⑤
① Door/Wall
② Door station front
③ Door station bracket
② Door station front
⑤ PC plate
③ Door station bracket
G9 SHELL
4.Then insert the right
edge into groove.
④ Screw ⑤ Plugs
Dimensions
5.Push the left edge
and move to left.
Unit: mm
132
150
64
106
① Door/Wall
② Door station front
③ Door station bracket
④ Screw
68.5
254
202
272
Unit: mm
252
S6 SHELL
130
①
Mounting
①Wall
③Door station bracket
⑤Screw
Change name plate
③
②Door station front
④Plastic pipe
⑥Anti-dismantle screw
④
②
Name plate
Plastic
1.Insert the screw driver in the notch.
Turn and push the plastic upwards.
2.Change the name plate.
3.Put the plastic back to the groove.
⑥
19 Kit
⑤
Kit 20
General Catalogue
Kit
S4 SHELL
Unit: mm
①Door/Wall
②Door station front
③Door station bracket
④Screw
S2 SHELL
28
① Door/Wall
② Panel
Unit: mm
③ Frame
①
④ Anti-dismantle screw
⑤
⑤ Screw
③
126
88
②
92
④
Change name plate
Name plate
Plastic
1.Insert the screwdriver in the notch. Turn and push the plastic upwards.
2.Change the name plate.
3.Put the plastic back to the groove.
OUTDOOR STATION
D2 SHELL
Unit: mm
L1=(L+26)
90
D1
Installation size on iron door
Model
WL-06DD2
21 Kit
Cover length Door station
L(mm)
size(mm)
138
174×130×50
W2
W3
D2
L3
L2=(L+24)
W1
DIRECT CALL PANEL AND DIGITAL PANEL
Installation size on wall
Installation size on
iron door (mm)
Installation size on
wall (mm)
166( L1)×108(W1) ×38(D1) 164( L2)×126( W2)×42(D2)
Door station 22
General Catalogue
Outdoor station
(Unit:mm)
■ DIMENSION
DIRECT CALL PANEL
Installation dimension
■ Features
■ Change the name plate
Aluminum alloy panel for the outdoor stations present a beautiful and generous
appearance.
( Applicable to single-row
door station )
Audio,E shell(for 1+N system)
Code
Model size
B-1
On the gate
On the wall
216×140×52
208×108×38
250×126×42
B-2
304×140×52
296×108×38
294×126×42
B-3
260×140×52
252×108×38
206×126×42
B-4
348×140×52
340×108×38
294×126×42
References
DIRECT CALL PANEL
Item
WL-02NE1×2 WL-02NE1×3 WL-02NE1×4 WL-02NE1×6 WL-02NE1×8 WL-02NE2×6 WL-02NE2×8
Dimension
(refer to P24)
B-1
B-1
B-1
B-2
B-2
B-2
B-2
■ Features
Vandal resistant panel,stainless steel construction,waterproof,ID card,service button.
SERVICE button: In the authorized time, press SERVICE button on the outdoor station to release the door.
[This button is special for postmen or other service people. The function has to be programmed by the remote control.Please refer to page 50.]
Video,E shell(for 5+N system)
Video,G9 shell(for C-5 system)
Item
Dimension
(refer to P24)
CM-02NE2×6-C
CM-02NE2×8-C
CM-02NE1×2 CM-02NE1×3 CM-02NE1×4 CM-02NE1×6 CM-02NE1×8
CM-02NE2×6
CM-02NE2×8
B-3
B-3
B-3
B-4
B-4
B-4
t
B-4
References
References
Se
CM-02NE1×2-C CM-02NE1×3-C CM-02NE1×4-C CM-02NE1×6-C CM-02NE1×8-C
Item
C2313D-C
C2315D-C
C2317D-C
C2319D-C
Video ,E shel l(for C-5 system)
■ Change name plate
References
■ Remove the upper and
lower end covers
Item
Dimension
(refer to P24)
23 Outdoor station
C2310-C
B-4
When installing the door station ,
the upper and lower end covers
shall be removed .
Use a slotted screwdriver to
slightly pry up from both sides,
as shown in the below figure ,
and then the end covers will
bounce out .
4.Put in the name
tag.
5.Insert the right
edge into sideling.
6.Push the left edge
7.Finish.
and move to left.
[Note: All the same to the other small name tags.]
Outdoor station 24
General Catalogue
Outdoor station
DIGITAL PANEL
■ Camera adjustment
Video,G9 shell(for C-5 system)
■ FEATURES:
A:for up and down
•Vandal resistant panel, stainless steel
construction, waterproof, flush mounted.
•Compatible with all video indoor phones in C-5
system.
•Door can be released by various methods such
as indoor phone,guard unit, ID card,password,
•SERVICE button and EXIT button.
•The IR illumination supports clear image even at
night.
•A sound system is programmed for friendly
intercommunication.
•The LCD window on the door panel makes the
program very easy.
B:for left and right
SPEAK DOOR
NOW OPEN
SERVICE
Right
References
Left
Item
C2608D-C
08D-C
Dimensions
■
■ Installation
65.5
63.0
480
500
150
106
■
Installation
63
132
482
Up
430
Down
SPEAK DOOR
NOW OPEN
SERVICE
68.5
130
Model size: 500×150×68.5 mm
Installation size: 482×132×63 mm
E2 shell(for C-5 system)
Working parameters:
Working voltage: DC 35V
Current: 50mA (DC 35V) stand by,200 mA when on
Environment temperature: -20℃ ~ +70℃
■ Dimensions
65.5
63.0
150
106
132
63
Model size: 410×150×68.5 mm
Installation size: 392×132×63 mm
SPEAK DOOR
NOW OPEN
SERVICE
68.5
25 Outdoor station
130
References
392
340
390
410
■ FEATURES
C9E21L
Item
C9E21L-C
C8E21L
Aluminium alloy panel,water proof.
Compatible with all video indoor stations in C-5 system.
Door alarm function.
Door can be released by various methods such as indoor
Station,guard unit,ID card,password, or EXIT button.
The IR illumination supports clear image even at night.
The LCD window on the door panel makes the program
very easy.
Outdoor station 26
General Catalogue
Outdoor station
■ Dimensions
135
■ Installation
Unit:mm
Flush-mounted
330
57
Surface-mounted
■ Adjust the angle of camera
As showing in the picture, move the
rocker leftward or rightward to adjust the
angle of camera
■ RAIN CAP INSTALLATION
Step 1
Step 2
3
②
2
3
②
2
5
7
4
3
②
6
②
1
8
8
INDOOR STATION
①
①
CHOOSE HANDSET OR HANDS-FREE YOU LIKE
1 Cushion
2
Rain cap
3
Back cover
4
Plug
5
Panel
7
M4x28 mm screw
①13×12×5 mm (bottom)
②20×10×10 mm
6
Screw
8
Plastic
expending pipes
Step 1:Paste the cushion to the back cover, which can keep the outdoor station on the middle of the rain cap perfectly.
Step 2:①
②
③
④
Fix therain cover on the wall by 4 screws
Put the back cover inside the rain cover and fix it wiht 4 screws
Put the out door panel into the back cover and fix it with 2 M4×28 mm screws
Put the plug back to the out door station
27 Outdoor station
Indoor station 28
General Catalogue
Indoor station
D SHELL
FUNCTION
Unlock Button
Standby button for future use
TECHNICAL SPECIFICATION
For 1+N system
a)Working Voltage:DC12V±10%
b)Current:0mA stand by,30mA when on
REFERENCES
5-wire audio system
WL-06DFaD Audio,Master handset
WL-06DFbD Audio,Subsidiary handset
c)Environment Temperature:-10~+55℃
d)Humidity :45% ~ 95%
DIMENSION
1+N system
WL-02NEFD Audio handset
For 5-wire audio system
COMPATIBILITY
WL-06DFaD Main Indoor station
Available for 5-wire audio system and 1+N system
a)Working Voltage:DC15V±10%
b)Current:0mA stand by,15mA when on
c)Environment Temperature:-10~+55℃
INSTALLATION METHODS
Method 1
202mm
144mm
60mm
d)Humidity :45% ~ 95%
Method 2
WL-06DFbD Subsidiary Indoor station
a)Working Voltage:DC15V±10%
b)Current:0mA stand by,15mA when on
c)Environment Temperature:-10~+55℃
80mm
d)Humidity :45% ~ 95%
67mm
Surface-mounted
29 Indoor station
Indoor station 30
General Catalogue
Indoor station
H3 SHELL
H4 SHELL
COMPATIBILITY
TECHNICAL SPECIFICATION
Available for 2-wire audio system and C-5 system.
COMPATIBILITY
TECHNICAL SPECIFICATION
Available for 2-wire audio system and C-5 system.
For 2-wire audio system
a)Working Voltage:DC14V±10%
a)Working Voltage:DC24V
b)Current:0mA stand by,15mA when on
b)Current:40mA stand by,100mA when on
c)Environment Temperature:-10~+55℃
c)Environment Temperature:-10~+55℃
FUNCTION
For 2-wire audio system
FUNCTION
d)Humidity :45% ~ 95%
d)Humidity :10% ~ 95%
For C-5 system
For C-5 system
a)Working Voltage:DC35V
Unlock Button
1. In standby mode, pick up the
handset, and press it, the other
indoor station will ring.
2. Pick up the handset from one of
the ringing indoor station to
answer the call.Any other
indoor station will stop ringing.
b)Current:0mA stand by,100mA when on
c)Environment Temperature:-10~+55℃
In the mute status,
the indoor station is
called while it flashes
a)Working Voltage:DC35V
Unlock button
c)Environment Temperature:-10~+55℃
Mute switch:
set this switch
to turn off/on
the ring
d)Humidity :10% ~ 95%
b)Current:0mA stand by,100mA when on
d)Humidity :10% ~ 95%
DIMENSION
DIMENSION
84mm
80mm
67mm
36.5mm
202mm
60mm
144mm
60mm
220mm
Note:
In the mute status, if the visitor calls the indoor station, it
will not ring, but the light flashes,and you can still talk with
the visitor or open the door for the visitor.
Surface-mounted
Surface-mounted
REFERENCES
2-wire video system
7H30P
31 Indoor station
INSTALLATION METHODS
Method 1
Audio,handset
Method 2
INSTALLATION METHODS
2-wire audio system
D3H40
Audio,Subsidiary handset
C-5 system
3005
REFERENCES
Audio handset
Method 1
Method 2
C-5 system
3006
Audio,handset
Indoor station 32
General Catalogue
Indoor station
V1 SHELL
FUNCTION
The system is working while it is on
Available to talk while it is on
System is busy while it is on
Press it to talk
(available in network system only)
1.Press talk button,then press this
button,you can call the guard unit.
2.Press this button directly,the guard
unit will receive an alarm message.
Press it to survey the entrance
TECHNICATION SPECIFICATION
Press it to unlock for visitor
For 4-wire system
a)Color:5"TFT screen
b)Resolution:320×234 lines
c)Working Voltage:DC14V±10%
d)Current:100mA stand by,700mA when on
e)Environment Temperature:-10~+55℃
Brightness adjustment
Contrast adjustment
Talk volume adjustment
Ring volume adjustment
INSTALLATION METHODS
COMPATIBILITY
Available for 4-wire system, 2-wire system,5+N
system and C-5 system .
Method 1
Method 2
For C-5 system
a)Color:5"TFT screen
b)Resolution:320×234 lines
c)Working Voltage:DC35V±10%
d)Current:25mA stand by,350mA when on
e)Environment Temperature:-10~+55℃
DIMENSION
For 2-wire system
7010K Master Indoor station
a)Color:5"TFT screen
b)Resolution:320×234 lines
c)Working Voltage:DC24V±10%
d)Current:100mA stand by,500mA when on
e)Environment Temperature:-10~+55℃
7010P Subsidiary Indoor station
a)Color:5"TFT screen
b)Resolution:320×234 lines
c)Working Voltage:DC24V±10%
d)Current:100mA stand by,350mA when on
e)Environment Temperature:-10~+55℃
REFERENCES
4-Wire system
F3010
25mm
150mm
80mm
220mm
Surface-mounted
33 Indoor station
For 5+N system
120mm
a)Color:5"TFT screen
b)Resolution:320×234 lines
c)Working Voltage:DC18V±10%
d)Current:10mA stand by,400mA when on
e)Environment Temperature:-10~+55℃
Video,Color
2-Wire system
7010K
Video,Color, Master
7010P
Video,Color,Subsidiary
5+N system
CM-02NERV1 Video,Color
C-5 system
3054
Video,Color
Indoor station 34
General Catalogue
Indoor station
V3 SHELL
FUNCTION
The system is working while it is on
Available to talk while it is on
System is busy while it is on
The ring volume is closed while it is on
Standby button for future use
Standby button for future use
Press it to survey the entrance
Press it to unlock for visitors
Press it to talk
Brightness adjustment
Contrast adjustment
COMPATIBILITY
Talk volume adjustment
Available for 4-wire system, and C-5 system .
DIMENSION
Ring volume adjustment
INSTALLATION
61mm
TECHNICAL SPECIFICATION
REFERENCES
For 4-wire system
4-wire system
a)Color:3.5"TFT screen
b)Resolution:160×234 lines
c)Working Voltage:DC14V±10%
d)Current:100mA stand by,700mA when on
e)Environment Temperature:-10~+55℃
F3030
Video,Color
C-5 system
3031
Video,Color
For C-5 system
120mm
185mm
35 Indoor station
28mm
Surface-mounted
a)Color:3.5"TFT screen
b)Resolution:160×234 lines
c)Working Voltage:DC35V±10%
d)Current:25mA stand by,350mA when on
e)Environment Temperature:-10~+55℃
Indoor station 36
General Catalogue
Indoor station
V11 SHELL
FUNCTION
The system is working while it is on
System is busy while it is on
The ring volume is closedwhile it is on
Press it to survey the entrance
Press it to close/open the ring
(available in network system only)
1.Press talk button,then press this
button,you can call the guard unit.
2.Press this directly,and the guard
unit will receive an alarm message.
Spare to future use
Press it to talk
Press it to release the door
Brightness adjustment
Contrast adjustment
Ring volume adjustment
Talk volume adjustment
COMPATIBILITY
INSTALLATION METHODS
Method 1
Method 2
Available for 4-wire system and C-5 system .
TECHNICAL SPECIFICATION
DIMENSION
120mm
For 4-wire system
For C-5 system
a)Color:7"TFT screen
b)Resolution:480×234 lines
c)Working Voltage:DC14V±10%
d)Current:100mA stand by,700mA when on
e)Environment Temperature:-10~+55℃
a)Color:7"TFT screen
b)Resolution:480×234 lines
c)Working Voltage:DC35V±10%
d)Current:25mA stand by,350mA when on
e)Environment Temperature:-10~+55℃
220mm
80mm
REFERENCES
4-wire system
208mm
37 Indoor station
46mm
Surface-mounted
F3110
Video,Color
C-5 system
3064
Video,Color
Indoor station 38
General Catalogue
Indoor station
V12 SHELL
FUNCTION
The system is working while it is on
Available to talk while it is on
System is busy while it is on
Standby button for future use
Press it to unlock for visitors
Press it to survey the entrance
With built-in power supply
TECHNICAL SPECIFICATION
Brightness adjustment
Contrast adjustment
Ring volume adjustment
COMPATIBILITY
Available for 4-wire system,5+N system and C-5
system .
INSTALLATION METHODS
DIMENSION
REFERENCES
For 4-wire system
4-wire system
a)B/W:4"CRT screen
b)Resolution:>450 lines
c)Working Voltage:DC14V±10%
d)Current:100mA stand by,700mA when on
e)Environment Temperature:-10~+55℃
F3120-B
Video,B/W handset
F3120-BN
Video,B/W handset
Built-in Power Supply
For 5+N system
CM-02NERV12
a)B/W:4"CRT screen
b)Resolution:>450 lines
c)Working Voltage:DC18V±10%
d)Current:10mA stand by,500mA when on
e)Environment Temperature:-10~+55℃
C-5 system
5+N system
3065
Video,B/W handset
Video,B/W handset
61mm
For C-5 system
220mm
105mm
203mm
63mm
Surface-mounted
39 Indoor station
a)B/W:4"CRT screen
b)Resolution:>450 lines
c)Working Voltage:DC35V±10%
d)Current:10mA stand by,350mA when on
e)Environment Temperature:-10~+55℃
Indoor station 40
General Catalogue
Indoor station
V13 SHELL
FUNCTION
Spare to future use
System is busy
while it is on
The ring volume is closed while it is on
The system is
working while it is on
Spare to future use
Standdby button for future use
Press it to unlock for visitors
Press it to talk
1.Press it to close/open the ring
2.Press it to shield the noise outside
Press it to survey the entrance
Standby button for future use
Brightness adjustment
Contrast adjustment
COMPATIBILITY
Ring volume adjustment
Available for 2-wire system and C-5 system .
DIMENSION
Talk volume adjustment
INSTALLATION
120mm
150mm
80mm
220mm
27mm
Surface-mounted
41 Indoor station
TECHNICAL SPECIFICATION
REFERENCES
For 2-wire system
2-wire system
7130K Master Indoor station
7130K
Video,Color, Master
a)Color:7"TFT screen
b)Resolution:480×234 lines
c)Working Voltage:DC24V±10%
d)Current:100mA stand by,500mA when on
e)Environment Temperature:-10~+55℃
7130P
Video,Color, Subsidiary
7130P Subsidiary Indoor station
a)Color:7"TFT screen
b)Resolution:480×2344 lines
c)Working Voltage:DC24V±10%
d)Current:100mA stand by,350mA when on
e)Environment Temperature:-10~+55℃
For C-5 system
3066
Video,Color
For C-5 system
a)Working Voltage:DC35V
b)Current:25mA Stand by,350mA when on
c)Environment Temperature:-10~+55℃
d)Humidity :10% ~ 95%
Indoor station 42
General Catalogue
Indoor station
V20 SHELL
FUNCTION
The system is working while it is on
Available to talk while it is on
System is busy while it is on
Talk volume adjustment
Press it to talk
Press it to unlock for visitors
Brightness adjustment
Contrast adjustment
Ring volume adjustment
Press it to survey the entrance
COMPATIBILITY
TECHNICAL SPECIFICATION
Available for 4-wire system,5+N system and C-5
system .
For 4-wire system
DIMENSION
a)B/W:4"CRT screen
b)Resolution:>450 lines
c)Working Voltage:DC14V±10%
d)Current:100mA stand by,700mA when on
e)Environment Temperature:-10~+55℃
For 5+N system
220mm
46mm
203mm
INSTALLATION METHODS
61mm
a)B/W:4"CRT screen
b)Resolution:>450 lines
c)Working Voltage:DC18V±10%
d)Current:10mA stand by,500mA when on
e)Environment Temperature:-10~+55℃
ACCESSORIES
NEEDS EXCEPT OUTDOOR STATION AND INDOOR STATION
For C-5 system
105mm
Surface-mounted
a)B/W:4"CRT screen
b)Resolution:>450 lines
c)Working Voltage:DC35V±10%
d)Current:10mA stand by,350mA when on
e)Environment Temperature:-10~+55℃
REFERENCES Surface-mounted
4-wire system
F3200-B
Video,B/W handfree
C-5 system
C3200-B
Video,B/W handfree
5+N system
CM-02NERV20
43 Indoor station
Video,B/W handfree
Accessories 44
General Catalogue
Accessories
F4300
DISTRIBUTOR
For 4-wire system
Switch the audio and video signal from and to the 2 villa
outdoor stations.
It is applied when there are two door entrance in a same villa.
CM-02NECH-162 For 5+N system
Ref.F4300
Distribute the audio and vidoe signal, it can support up
to 4 indoor stations in each apartment.
Ref.CM-02NECH-162
C4113
SWITCH
For C-5 system
Distribute the audio and vidoe signal,it can support up
to 4 indoor stations for different apartment or the same
C4401
apartment according you need.
For C-5 system
Intermediate equipment
Ref.C4113
Exchange data between gateway / gate station and guard unit
Up to12 ports can be connected.
Auto commissioning for gateway, gate station and guard unit.
4110S/4110
For C-5 system
Ref.C4401
Distribute the audio and vidoe signal,it can support up
to 4 indoor stations under the same room number.
Ref.4110S
GATE-WAY
CM-02NEQH
ACCESSARY DOOR STATION
For 5+N system
WL-02NEK 1X10
Switch the audio and video signal from and to two outdoor
For 1(5)+N system
stations.
It is used when the outdoor station can’t meet the need of
It is applied when there are two door entrance in a same
user’s apartment quantities.
building.One gate-way supports up to 12 apartments.
Ref.CM-02NEQH
Specifications
a)Operating voltage: DC 12.6V
C4301
b)Current:70mA Stand by,75mA when on
For C-5 system
c)Temperature: -40℃~ +70C
d)Humidity: 45% ~ 95%
Network equipment.(master)Exchange the audio and video
signal.
Ref.WL-02NEK1×10
Ref.C4301
45 Accessories
Accessories 46
General Catalogue
Accessories
POWER SUPPLY
PS-2E
For 1+N system
Input voltage:AC 110/230V
Output voltage:DC 13.5V
Output current:0.8A
Type:linear power supply
4008
50/60HZ
For C-5 system
Input voltage:AC 90V ~ 130V 50/60HZ
Output voltage: DC 35V
Output current :1.4A
Type: switch power supply
Ref.PS-2E
Ref.4008
PS-3E
For 1+N system
Input voltage: AC 230V 50/60HZ
Output voltage:DC 12V
Output current:0.8A
Type:linear power supply
4013
For 4-wire system
Input voltage:AC 100V ~ 240V 50HZ
Output voltage:DC 14V
Output current:0.8A
Type: switch power supply
Ref.PS-3E
PS-5E
Ref.4013
For 5+N system
Input voltage: AC 110/230V
Output voltage:DC 18V
Output current:0.8A
Type:linear power supply
50/60HZ
4014
Ref.PS-5E
4001
Ref.4014
For C-5 system
Input voltage: AC 180 ~ 270V 50/60HZ
Output voltage:DC 35V
Output current:1.4A
Type:switch power supply
4016
Ref.4001
4003
For 2-wire system
Input voltage:AC 230V
Output voltage:DC 24V / AC 12V
Output current:0.6A / 0.5A
Type:linear power supply
For 4-wire system
Input voltage:AC 230V
Output voltage:DC 14V / AC 12V
Output current:1.5A / 1A
Type:linear power supply
Russia only
For 5-wire system
Ref.4016
Input voltage: AC 220 V 50HZ
Output voltage:DC 15V / DC 12V
Output current:0.3A / 0.6A
Type: linear power supply
4017
Ref.4003
Italy only
4007
For 5+N system
For 2-wire system
Input voltage:AC 100V ~ 240V 50HZ
Output voltage:DC 24V
Output current:0.8A
Type:switch power supply
Application: C-5 system
Ref.4017
Input voltage: AC 230V 50HZ
Output voltage:DC 18V / AC 12V
Output current:1.5A / 1A
Type:linear power supply
Ref.4007
47 Accessories
Accessories 48
General Catalogue
Accessories
Wall Installation
GATE STATION
C6831D-C
Iron door Installation
Unit:mm
Unit:mm
For C-5 system
Be fitted on the main entrance,with the intercom,door
release and other functions.
Product Features
◆ Zinc alloy panel, water proof
◆ Send alarm message to guard unit when door is not closed well
◆ Different methods to enter the residential complex with gate station, e. g.
throug indoor station , guard unit, ID card , password or EXIT button
◆ Camera with LED light for clear colorful picture especially at night
REMOTE CONTROL
Specifications
Specifications
Key
a)Camera:
Adjustable angle: 10°
Visible angle: 90°
Light source: White light LED
Ref.C6831D-C
b)Operating voltage: DC 35V
c)Current: 90mA Stand by,260mA when on
d)Temperature: -20℃~+70℃
e)Model size: 70.6×38.6 mm
f )Resolution: 128×64 lines
Camera adjustment
For C-5 system / 4-wire system
Dimensions
Unit:mm
Function
TIME
Report time or program /time & date/.
RING
Choose ring type or program ring volume.
UNLOCK
Program /Unlock time/.
0~9
Digits
SERVICE
Program /SERVICE function/.
EXTRA
Program cards together with /REG-/ and
/DEL+/ buttons
CLEAR
Delete the wrong number.
EXIT
Back to the top menu or out of program.
REG -
Register cards or turn down the ring volume.
DEL+
Cancel cards or turn up the ring volume.
ENTER
Confirm button
FN
Function button
It is applied in G9 shell direct call outdoor
stations.
Specifications
a)Battery: DC 3V, 1.5V AAA(2pcs)
b)Available distance: ≤3 meters
c)Angle: ≥30°
49 Accessories
Accessories 50
General Catalogue
Accessories
GUARD UNIT
C6806D-C
For C-5 system
Monitor any outdoor station,two-way communication with
all users, review and save the alarm records.
Product Features
◆ Intercom with indoor station, outdoor station or gate
station
◆ Can monitor the outdoor station or gate station
◆ Entrance door can be opened via guard unit
◆ Can register ID cord for resident and patrol
card for security guard
Specifications
Ref.C6806D-C
Appearance&Functions
SYSTEM DIAGRAM
Call button (indoor phone):pree this button, then input indoor station NO. to call.
HOW TO CONNECT THE SYSTEM
out
Unlock button: press this button to unlock the outdoor station or perimeter gate station.
51 Accessories
System Diagram 52
General Catalogue
System diagram
4-WIRE VIDEO SYSTEM
■ Optional:
If you want to connect 2 outdoor stations and 4 indoor station,please refer to the diagram as follows.
VDOOR
COM
AUDIO
NC
GND
NO
VIDEO
GND
4
3
2
1
Outdoor station 1#
DC14V
Outdoor station
Indoor station
If you want to connect 1 outdoor station and 4 indoor stations,please refer to the diagram as follows.
4
3
2
1
VDOOR
COM
AUDIO
NC
GND
NO
VIDEO
Outdoor station 2#
DC14V
If you want to connect 1 outdoor station and 1 indoor station,please refer to the diagram as follows.
+
Indoor station
Outdoor station
switch
Outdoor station 1
Indoor station
Outdoor station 2
Outdoor station
4
Power supply
Power supply
-
VDOOR
AUDIO GND
DC14V
GND
VIDEO
3
2
1
VDOOR
AUDIO GND
DC14V
GND
VIDEO
Gateway
Power supply
VDOOR
COM
AUDIO
NC
GND
NO
VIDEO
Outdoor station
VDOOR
AUDIO
GND
VIDEO
GND
DC14V
The last indoor station
video matching jumper
should be "ON".
VDOOR
AUDIO
GND
VIDEO
hand in hand, as the right
diagrams shows.
Video matching
Indoor station 3#
GND
DC14V
Video matching
[Note]
VDOOR
AUDIO
GND
VIDEO
The last indoor station's
video matching jumper
should be "ON".
Video matching
Indoor station 4#
(Last one)
GND
DC14V
Video matching
Indoor station 3#
VDOOR
AUDIO
GND
VIDEO
VDOOR
AUDIO GND
DC14V
GND
VIDEO
wiring between indoor
! The
station must be connected
Video matching
Indoor station 2#
Power supply
[Note]
Video matching
Indoor station 2#
Power supply
Indoor station 1#
Power supply
VDOOR
AUDIO
GND
VIDEO
Video matching
Indoor station 1#
Power supply
Wiring suggestion:
Wiring distance from outdoor station to the last indoor station should be less than 100m.
1. If distance≤ 50m, use quad cable, with the single wire resistance <4Ω. Recommend
RVV4×0.75 wire.
2. If distance>50m, use 2-core cable and coaxial-cable, with the single wire resistance
<4Ω. Recommend RVV2×1.0 and SYV-75-5 wire.
1) VDOOR, AUDIO terminal use 2-core cable.
2) VIDEO, GND terminal use coaxial cable.
Video matching
Indoor station 4#
53 System diagram
System diagram 54
General Catalogue
System diagram
2-WIRE AUDIO SYSTEM
■ Optional:
Outdoor station
Indoor station
If you want to connect 1 outdoor station and 4 indoor stations,please refer to the diagram as follows.
Outdoor station
Master indoor station
If you want to connect 1 audio outdoor station and 1 audio indoor station,please refer to the diagram as
follows.
Indoor station
Outdoor station
Sub. indoor station 1#
2-WIRE VIDEO SYSTEM
■ Optional:
Outdoor station
Indoor station
Sub. indoor station 2#
If you want to connect 1 video outdoor station and 1 video indoor station,please refer to the diagram as
follows.
Sub. indoor station 3#
Outdoor station
Master indoor phone
Type of cable
RVV2×0.75mm
SYV-75-5-2
UTP5
55 System diagram
Distance between outdoor station
last indoor station
2
≤100m
≤200m
Wiring suggestion:
Distance between outdoor station and last indoor station
depends on the type of the cable used. Recommend
Cable and the maximum distance between outdoor
station and last indoor station shows on left side.
≤200m
System diagram 56
General Catalogue
System diagram
5-WIRE AUDIO SYSTEM
2-WIRE VIDEO SYSTEM
■ Optional:
If you want to connect 2 outdoor stations and 4 indoor stations,please refer to the diagram as follows.
Outdoor station 1#
Outdoor station
Indoor station
Master indoor station
If you want to connect 1 outdoor station and 1 indoor station,please refer to the diagram as follows.
Black
Red
Yellow
Green
Blue
Outdoor station 2#
PS-3E
Power
12V
+
+ -
Electrical lock
Adaptor
Sub. indoor station 1#
101 SOUT SIN GND POWER LK- LK+ COM
Indoor station
Outdoor station
If you want to connect 1 outdoor station and 4 indoor stations,please refer to the diagram as follows.
Black
Red
Yellow
Green
Black
Red
Yellow
Green
Blue
Black
Red
Yellow
Green
Black
Red
Yellow
Green
Sub. indoor station 2#
PS-3E
Power
12V
+
+ -
Electrical lock
Adaptor
101 SOUT SIN GND POWER LK- LK+ COM
Sub. indoor station 3#
(Last one)
Switches on back of the indoor station.
Unlock time setting:
Video matching:
(Only for the Master indoor station)
Unlock time:5s
Unlock time:1s
(Only for the Master indoor station)
ON
OFF
57 System diagram
ON
OFF
The last indoor station switch should
be“NO”,and the other Sub. indoor
station switch should be “OFF”.
Main Indoor station
Sub. Indoor station 1#
Sub. Indoor station 2#
Sub. Indoor station 2#
Outdoor station
[Note]
1. An optional exit button can be fitted to the Master
monitor to provide unlocking for the door. (Just for the
unlocking is applied to the master indoor station lock).
2. Please wire the system as the diagram one by one.
Wiring suggestion:
Wiring between outdoor station and indoor station: Within the distance of 50 meters, use
wire thicker than RVV5×0.5mm2 multi-copper wire. Wire cross section should be adjusted
according to wire distance.
System diagram 58
General Catalogue
System diagram
1(5)+N SYSTEM:The system is the direct-call structure, which is easy to install and commissioning. The surface-mounted
indoor station supports communication with the outdoor station and has as remote unlock and monitor function. The outdoor
station uses built-in infrared light, by which the visitor can be clearly identified even at night.
1+N AUDIO SYSTEM
5+N VIDEO SYSTEM(WITH CM-02NEQH)
When there are two entrances in the same building,please refer to the diagram as follows.
■ Optional:
Outdoor station
Indoor station
101
201
TV- TV+MONIGND
Bus
4
POWER
GND
GND
LOCK+
VCC
T&R
VCC
T&R
UD
UD
GND
GND
ULSW
A1 A2 A3 A4 A5 A6 A7 A8 B1 B2 B3 B4 B5 B6 B7 B8
Accessary Outdoor station
Outdoor station 1
402
101
201
TV- TV+MONIGND
402
4
1
1
1
Indoor station8#
2
2
2
Outdoor station
Outdoor station 2
Indoor station2#
TV+
Indoor station1#
MONI
TV+
5+N VIDEO SYSTEM
MONI
■ Optional:
VGND
Outdoor station
Indoor station
TV
DC
+
-
DC+
主机切换器
TV
VGND
GND
Indoor station
MONI
TV
AGND
VGND
GND
V+18V
A+18V
MONI
Bus
T&R
1
VCC
T&R
VCC
T&R
UD
UD
GND
GND
ULSW
Outdoor station
59 System diagram
4
5
6
TV
GND
LOCK+
VGND
POWER
GND
GND
Accessary outdoor station
V+18V
MONI
1
2 3
4
5
6
7
Indoor station1#
8
1
2 3
4
5
6
Indoor station8#
T&R
TV
T&R4
VGND
GND
MONI
MONI
POWER
2 3
T&R
TV-
A1 A2 A3 A4 A5 A6 A7 A8 B1 B2 B3 B4 B5 B6 B7 B8
TV+
Gateway
Indoor station
From outdoor staion to cross-section
the last indoor station of conductor
Video cable
1
2 3
4
5
6
7
8
T&R
[Note]
When the hands-free indoor station is used in the system, two groups of
power cords must be drawn out from the POWER and GND terminals of the
outdoor station, one connecting to the audio power supply (A+18V, AGND)
of the indoor phone, and the other connecting to the video power supply
(V+18V, GND) of the indoor phone.
0-50M
50-100M
0.5mm2
75-3
2
75-5
1.0mm
System diagram 60
General Catalogue
System diagram
5+N VIDEO SYSTEM(WITH CM-02NECH-162)
C-5 SYSTEM
When you need 4 indoor stations in the same apartment,please refer to the diagram as follows
From outdoor station to
the last indoor station
cross-section
of conductor
0-50M
0.5mm2
75-3
2
75-5
50-100M
1.0mm
To outdoor station
POWER
T&R
101
GND
201
MONI
TVTV+
VGND
MONI
TV
T&R
To indoor station
DC
-
GND
Indoor station
C-5 SYSTEM:
(1)In digital call system, easily installation and commissioning.
(2)Hand-up indoor station, with the function of communication with the management device and alarm and remote control
unlocking.
(3)Door can be released by various methods such as indoor station,guard unit,ID card,password,or EXIT button.
(4)Optional indoor station number of 2 bit,3 bit and 4 bit
(5)Optional ring with 4 kinds of chord.
(6)One outdoor station can load 200 distributors.
(7)One distributor can be connected with 4 indoor stations.
Indoor station8#
CAT.5
GND
Distributor
1 T&R
2 GND
+18V
CAT.5
VGND
GND
MONI
CAT.5
GND
MONI
T&R
Indoor station7#
POWER
T&R
T&R
CAT.5
Indoor station5#
+
DC
TV
To indoor station
Outdoor station
Video cable
+
GND
■ Optional:
Indoor station6#
CAT.5E
GND
MONI
Indoor station4#
+18V
CAT.5
VGND
Indoor station3#
CAT.5
VGND
TV
TV
Distributor
T&R 6
GND 4
MONI 5
7 AGND
CAT.5E
Indoor station1#
8 TV
6 VGND
4 GND
5 V+18V
3 MONI
TV
CAT.5
CAT.5
1 A+18V
VGND
V+18V 3
TV 1
MONI
+18V
VGND 2
GND
2 T&R
To indoor station
T&R
Indoor station2#
To indoor station
T&R
GND
+18V
VGND
TV
Distributor
61 System diagram
Outdoor station
MONI
+
DC
2
Power
12V
+
Lock
-
Power supply
System diagram 62
General Catalogue
System diagram
C-5 VIDEO SYSTEM
When there are two entrances in the same building,please refer to the diagarm as follows.
Indoor station8#
CAT.5
When there are more(Max.8) door entrances in the same building,please refer to the diagarm as follows.
Indoor station7#
CAT.5
Indoor station8#
Distributor
CAT.5
Indoor station7#
CAT.5
Distributor
CAT.5
CAT.5
CAT.5
CAT.5
Indoor station5#
Indoor station5#
Indoor station6#
Indoor station6#
CAT.5e
Indoor station3#
Indoor station4#
CAT.5e
CAT.5
CAT.5
Distributor
Indoor station3#
Indoor station4#
CAT.5
CAT.5
CAT.5
CAT.5
Distributor
Indoor station1#
Indoor station2#
Outdoor station 1#
Power
12V
2
CAT.5
CAT.5
+ -
Lock Power supply2
Accessory outdoor station
Outdoor station 2#
extended distributor
Power
12V
CAT.5e
CAT.5e
Indoor station2#
Indoor station1#
Power supply
CAT.5e
Water proof
CAT.5e
Outdoor station1#
Outdoor station2#
Power
12V
Power supply
Power
12V
+
Lock
-
Power
12V
+
Lock
-
2
CAT.5e
Water proof
Outdoor station 6#
Power
12V
Lock
+ -
+ -
CAT.5e
Waterproof
[Note]
1.The waterproof CAT.5e should be used when working in wet
climate.
2.Additional power supply should be used when outdoor station 2# is
more than 30 meters away from gateway.
63 System diagram
Power
12V
+ -
Lock
Lock
CAT.5e
Outdoor station 7#
Power
12V
+ -
Lock
Outdoor station 8#
Power
12V
+ -
Lock
CAT.5e
Water proof
Gateway
Lock
CAT.5e
Water proof
Power supply
+ -
Outdoor station 4#
CAT.5e
Water proof
Accessory outdoor station
Outdoor station 5#
extended distributor
2
Power
12V
Lock
+ -
Water proof
Gateway
Outdoor station 3#
CAT.5e
Water proof
[Note]
1.The waterproof CAT.5e should be used when working in alway wet
climate.
2.Additional power supply should be used when any additional
outdoor station is more than 30 meters away from extended
distributor.
System diagram 64
65 System diagram
Power supply
2
CAT.5E
Indoor station
Gateway
CAT.5E
-
Power
12V
+
2
Lock
-
gate station
+
Power
12V
Lock
CAT.5E-waterproof
Indoor station
CAT.5
CAT.5
Indoor station
Indoor station
CAT.5
Indoor station
Outdoor station 1
CAT.5
Indoor station
CAT.5
Indoor station
CAT.5
CAT.5
Power supply
Distributor
Distributor
Indoor station
CAT.5
Power supply
CAT.5E-waterproof
2
Indoor station
-
Power
12V
Lock
Lock
Computer + Software
2
Power supply
CAT.5E-waterproof
Power supply
RS-232
(Serial Port Cable)
2
-
Power
12V
+
CAT.5E
CAT.5E-waterproof
CAT.5E
+
Indoor station
Outdoor station 2
Indoor station
CAT.5
CAT.5
Indoor station
CAT.5
Indoor station
Guard unit
CAT.5E-waterproof
Indoor station
CAT.5
Indoor station
CAT.5
CAT.5
CAT.5E
Switch
Gateway
2
Power supply
Indoor station
CAT.5
CAT.5
Outdoor station 1
Distributor
Distributor
Switch
Gateway
Indoor station
2
CAT.5
CAT.5
CAT.5
CAT.5
Indoor station
Indoor station
Indoor station
Indoor station
Power supply
2
-
Power
12V
Lock
CAT.5
CAT.5
CAT.5E
-
Power
12V
+
Lock
CAT.5E
Lock
Lock
CAT.5
CAT.5
CAT.5
CAT.5
-
Power
12V
+
Lock
+
-
Power
12V
Outdoor
station 5
Lock
Indoor station
Indoor station
Indoor station
Indoor station
Outdoor station 2
Indoor station
Indoor station
Indoor station
-
CAT.5E
+
Power
12V
Outdoor
station 4
Indoor station
CAT.5
CAT.5
-
CAT.5E
+
Power
12V
Outdoor
station 3
Outdoor station 1
CAT.5E
CAT.5E
CAT.5E
+
Gateway
Distributor
Distributor
CAT.5E
Accessory outdoor station Outdoor
extended distributor
station 2
Power supply
CAT.5E
CAT.5E-waterproof
-
Power
12V
+
Power
supply
Indoor station
Lock
CAT.5
Indoor station
Indoor station
CAT.5
CAT.5
CAT.5
Outdoor
station 1
CAT.5E
CAT.5E
Distributor
CAT.5E
Distributor
General Catalogue
System diagram
C-5 VIDEO
VEDIO SYSTEM (2-4)
If you want to connect all equipments in network system,please refer to the diagram as follows.
ACCESS CONTROL SYSTEM
KEYPAD AND CARD READER
Access control system 66
General Catalogue
Access control system
ACCESS CONTROL SYSTEM
ACCESS CONTROL SYSTEM
ECK-03A main functions
ECK-04A main functions
1)Record function.
2)Use remote control to operate with the sound and LED indicate.
3)When the distance is more than 1200 meters,data isolation
repeaters should be added
4)Support 4000 pcs ID card
5)Entrance guard and patrol in one card
1)Adopt advanced micro-computer CPU technology, can be applied in home, shop, office, factory, farm,
warehouse, bank, school, hospital.
2)The maximum capacity is 4000 pieces of cards.
3)The user’s information will be saved automatically,you don’t need to worry the lost of the information
when it is power off.
4)Unlock methods: (a)by card,(b)by card with password,(c)by entering the card number with password.
5)Setting alarm and dis-alarming: On setting alarm status,you can’t open the door in the above three
ways,unless in dis-alarming status.
6)Door status checking: Connect to a wired door magnetic first,when the door is open(not properly
closed),it will give a Di Di ring,if it is well closed,then it won’t ring.
7)Anti-dismantle function:When some one try to dismantle the card reader,the alarm host will alarm.
8)Supports single loop or double loop(add one more external loop).
DETAILED WIRING DIAGRAM
Connection for the network port and card reader:
12V
Power
DETAILED WIRING DIAGRAM
ECK-04A
Electrical
Lock
Power supply
DC10-13V
12V
Power
Card reader
Note:The working current for the electronic lock should ≤1A
Horn
Additional
loop
+12V
GND
ALARM
GND
ANT1
ANT2
DOORINGND
1.5 mH
+5V
GND
Door status
checking input
terminal
Electric
LOCK
GND
lock
Note:The working current of the electrical lock should be ≤1A
The output current of the power supply should be ≤0.8A
TECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION
⑴ Working voltage:DC12~18V
⑵ Working current:100mA
⑶ Data transmission:RS485 interface and infrared communication
⑷ Radio frequency:125KHz
⑸ Iinfrard modulate frequency:38khz
⑹ Induce distance:1-8cm
⑺ Transmission pass:double twist shield line
⑻ Reading card type:EM or Mifare card
⑴ Working voltage:DC10~13V
⑵ Static current:≤50mA
⑶ Working current:≤100mA
⑷ Dimension:110×72×34mm
⑸ Maximum capacity:4000 cards
⑹ Card reading distance:5-10cm
⑺ Applicable card:EM card or EM compatible card
⑻ Frequency:125 KHz
CARD
67 Access control system
Access control system 68
General Catalogue
Access control system
ECK-02N (Password keypad with metal housing)
NOTES
Main functions
1) Can support 250 users.
2) Support 2 to 8 digits passwords.
3) One administrator password,if lost the password,can be resumed to original password.
4) If input error password 3 times,keypad locked and voice alarm.
5) Open door time can be programmed from 1 to 99 seconds.
6) Door status check:If door is not closed properly,system will automatically give voice and flicker.
DETAILED WIRING DIAGRAM
ECK-02N
Door-status check
+5V
GND
Lock
- +
Power
NUL1
NUL2
GND
DECT
NO
COM
NC
REMOTE
AC
DC
NOTE:unlock
current should
be≤1A
AC/DC
DECTNO COMNCREMOTE
GND
TNCALARM
Terminals
NUL1: empty
NUL2:empty
GND:negative terminal
DECT:door-status-check input
NO:NO terminal for electical output
COM:electrical lock common terminal
NC:NC terminal for electrical output
REMOTE:remote unlock input terminal
AC:DC/AC terminal
DC:DC/AC terminal
GND
Remote unlock
control terminal
AC/DC
Power input
TECHNICAL SPECIFICATION
⑴ Working voltage:DC/AC12~18V
⑵ Working current:≤80mA
⑶ Static current:≤27mA
⑷ Relay current:2A
⑸ Password digit:2-8 digits passwords
⑹ Dimension:110×72×34mm
69 Access control system