Technical Data Sheet
Site Master™
Compact Handheld Cable & Antenna Analyzer
with Spectrum Analyzer
S331E
2 MHz to 4 GHz
S332E
S361E
2 MHz to 4 GHz 2 MHz to 6 GHz
100 kHz to 4 GHz
S362E
2 MHz to 6 GHz
Cable & Antenna Analyzer
100 kHz to 6 GHz Spectrum Analyzer
Introduction
Anritsu introduces its eighth generation compact handheld Cable and Antenna Analyzers with Spectrum Analyzers for
installation and maintenance of wireless networks. They feature the highest performance and the most capabilities ever
offered by Anritsu in a compact handheld tester since introducing its first line sweeper in 1995.
Cable and Antenna Analyzer Highlights
Spectrum and Interference Analyzer Highlights
•
•
•
•
•
•
•
•
•
•
•
•
Measurements: RL, VSWR, Cable Loss, DTF, Phase
2-port Transmission Measurement: High/Low Power
Sweep Speed: 1 msec/data point, typical
Display : Single or Dual Measurement Touchscreen
Calibration: OSL, InstaCal™ , and FlexCal™
Bias Tee: 32V internal
Measurements: Occupied Bandwidth, Channel Power, ACPR, C/I
Interference Analyzer: Spectrogram, Signal Strength, RSSI, Signal ID
Dynamic Range: > 95 dB in 10 Hz RBW
DANL: -152 dBm in 10 Hz RBW
Phase Noise: -100 dBc/Hz max @ 10 kHz offset at 1 GHz
Frequency Accuracy: < ±50 ppb with GPS On
Capabilities and Functional Highlights
• 4 hour battery operation time
• Store 2000 Traces internally
• Touchscreen keyboard
• A
M / FM / PM Analyzer
• High Accuracy Power Meter
• 4, 6, 8, 18 GHz USB Sensors
• Channel Scanner
• GPS tagging of saved traces
• USB Data Transfer
• <5 minute warm-up time
• E-Learning Training
• Certified Line Sweep Training
Site Master™ S331E Cable & Antenna Analyzer featuring 8.4” Daylight Viewable Touchscreen
Compact Size: 273 x 199 x 91 mm (10.7 x 7.8 x 3.6 in), Lightweight: 2.71 kg (6.0 lbs)
Site Master™ S331E, S332E, S361E, S362E Specifications
Cable and Antenna Analyzer
Measurements
Measurements
VSWR
Return Loss
Cable Loss
Distance-to-Fault (DTF) Return Loss
Distance-to-Fault (DTF) VSWR
1-Port Phase
Smith Chart
Setup Parameters
Measurement Display
Frequency
DTF
Windowing
Amplitude
Sweep
Data Points
Markers
Traces
Limit Line
Calibration
Save/Recall
Application Options
Single/Dual Measurement Display with independent markers
Start/Stop, Signal Standard, Start Cal
Start/Stop, DTF Aid, Units (m/ft), Cable Loss, Propagation Velocity, Cable, Windowing
Rectangular, Normal Side Lobe, Low Side Lobe, Minimum Side Lobe
Top, Bottom Auto Scale, Full Scale
Run/Hold, Single/Continuous, RF Immunity (High/Low), Data Points, Averaging/Smoothing,
Output Power (High/Low)
137, 275, 551, 1102, 2204
Markers 1-6 (On/Off), Delta Makers 1-6 (On/Off), Marker to Peak/Valley, Marker Table
Recall, Copy to Display Memory, No Trace Math, Trace ± Memory, Trace Overlay
On/Off, Single Limit, Multi-segment (41), Limit Alarm, Clear
Start Cal, Cal Type (Standard/FlexCal™)
Setups, Measurements (.vna, .dat), Screen Shots Jpeg (save only)
Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)
Frequency
Frequency Range
Frequency Accuracy
Frequency Resolution
2 MHz to 4 GHz (S331E, S332E), 2 MHz to 6 GHz (S361E, S362E)
≤±2.5 ppm @ 25 °C
1 kHz, (RF immunity low)
100 kHz, (RF immunity high)
Output Power
High
0 dBm, typical
Low
-30 dBm, typical
Interference Immunity
On-Channel
On-Frequency
+17 dBm @ >1.0 MHz from carrier frequency
0 dBm within ±10 kHz of the carrier frequency
Measurement Speed
Return Loss
≤1.00 msec/data point, RF immunity low, typical
Distance-to-Fault
≤1.25 msec/data point, RF immunity low, typical
Return Loss
Measurement Range
Resolution
0 to 60 dB
0.01 dB
VSWR
Measurement Range
Resolution
1 to 65
0.01
Cable Loss
Measurement Range
Resolution
0 to 30 dB
0.01 dB
Distance-to-Fault
Vertical Range Return Loss
Vertical Range VSWR
Fault Resolution (meters)
Horizontal Range (meters)
0 to 60 dB
1 to 65
(1.5 x 108 x vp)/∆F (vp = velocity propagation constant, ∆F is F2-F1 in Hz)
0 to (Data Points-1) x Fault Resolution, to a maximum of 1500 meters (4921 ft)
Page 2 of 16
Site Master™ S331E, S332E, S361E, S362E Specifications
Cable and Antenna Analyzer (continued)
1-Port Phase
Measurement Range
-180° to +180°
Resolution
0.01°
Resolution
0.01
Smith Chart
Measurement Accuracy
Corrected Directivity
>42 dB, OSL calibration
>38 dB, InstaCal™ calibration
Measurement Uncertainty
Page 3 of 16
Site Master™ S331E, S332E, S361E, S362E Specifications
Spectrum Analyzer (S332E, S362E)
Measurements
Smart Measurements
Field Strength (uses antenna calibration tables to measure dBm/m2 or dBmV/m)
Occupied Bandwidth (measures 99% to 1% power channel of a signal)
Channel Power (measures the total power in a specified bandwidth)
ACPR (adjacent channel power ratio)
AM/FM/SSB Demodulation (wide/narrow FM, USB and LSB), (audio out only)
C/I (carrier-to-interference ratio)
Setup Parameters
Frequency
Center/Start/Stop, Span, Frequency Step, Signal Standard, Channel #, Channel Increment
Amplitude
Reference Level (RL), Scale, Attenuation Auto/Level, RL Offset, Pre-Amp On/Off, Detection
Span
Bandwidth
File
Save/Recall
Save-on-Event
Delete
Directory Management
Application Options
Span, Span Up/Down (1-2-5), Full Span, Zero Span, Last Span
RBW, Auto RBW, VBW, Auto VBW, RBW/WBW, Span/RBW
Save, Recall, Delete, Directory Management
Setups, Measurements, Limit Lines, Screen Shots Jpeg (save only), Save-on-Event
Crossing Limit Line, Sweep Complete, Save-then-Stop, Clear All
Selected File, All Measurements, All Mode Files, All Content
Sort Method (Name/Type/Date), Ascend/Descend, Internal/USB, Copy, Format USB
Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)
Sweep Functions
Sweep
Single/Continuous, Manual Trigger, Reset, Detection, Minimum Sweep Time, Trigger Type,
Gated Sweep (see Option 0090)
Detection
Triggers
Peak, RMS, Negative, Sample, Quasi-peak
Free Run, External, Video, Change Position, Manual
Trace Functions
Traces
Up to three Traces (A, B, C), View/Blank, Write/Hold, Trace A/B/C Operations
Trace A Operations
Normal, Max Hold, Min Hold, Average, # of Averages, (always the live trace)
Trace B Operations
A B, BC, Max Hold, Min Hold
Trace C Operations
A  C, BC, Max Hold, Min Hold, A - B  C, B - A  C, Relative Reference (dB), Scale
Marker Functions
Markers
Markers 1-6 each with a Delta Marker, or Marker 1 Reference with Six Delta Markers,
Marker Table (On/Off), All Markers Off
Marker Types
Marker Auto-Position
Style (Fixed/Tracking), Noise Marker, Frequency Counter Marker
Peak Search, Next Peak (Right/Left), Peak Threshold %, Set Marker to Channel,
Marker Frequency to Center, Delta Marker to Span, Marker to Reference Level
Marker Table
1-6 markers frequency and amplitude plus delta markers frequency amplitude and offset
Limit Line Functions
Limit Lines
Upper/Lower, On/Off, Edit, Move, Envelope, Advanced, Limit Alarm, Default Limit
Limit Line Edit
Frequency, Amplitude, Add Point, Add Vertical, Delete Point, Next Point Left/Right
Limit Line Move
Limit Line Envelope
Limit Line Advanced
To Current Center Frequency, By dB or Hz, To Marker 1, Offset from Marker 1
Create Envelope, Update Amplitude, Points (41 max), Offset, Shape Square/Slope
Type (Absolute/Relative), Mirror, Save/Recall
Frequency
Frequency Range
Maximum Continuous Input
Tuning Resolution
Frequency Reference
Frequency Span
Sweep Time
Sweep Time Accuracy
100 kHz to 4 GHz (S332E), 100 kHz to 6 GHz (S362E) (usable to 0 Hz)
+26 dBm
1 Hz
Aging: ±1.0 ppm/year
Accuracy: ±1.5 ppm (25 °C ±25 °C) + aging, < ±50 ppb with GPS On
10 Hz to 4 GHz including zero span (S332E), 10 Hz to 6 GHz including zero span (S362E)
Minimum 100 ms, 10 µs to 600 seconds in zero span
±2% in zero span
Bandwidth
Resolution Bandwidth (RBW)
Video Bandwidth (VBW)
10 Hz to 3 MHz in 1–3 sequence ±10% (1 MHz max in zero-span) (–3 dB bandwidth)
1 Hz to 3 MHz in 1–3 sequence (–3 dB bandwidth) (auto or manually selectable)
RBW with Quasi-Peak Detection
200 Hz, 9 kHz, 120 kHz (-6 dB bandwidth)
VBW with Quasi-Peak Detection
Auto VBW is On, RBW/VBW = 1
Page 4 of 16
Site Master™ S331E, S332E, S361E, S362E Specifications
Spectrum Analyzer (S332E, S362E) (continued)
Spectral Purity
SSB Phase Noise @ 1 GHz
-100 dBc/Hz, -110 dBc/Hz typical @ 10 kHz offset
-105 dBc/Hz, -112 dBc/Hz typical @ 100 kHz offset
-115 dBc/Hz, -121 dBc/Hz typical @ 1 MHz offset
Amplitude Ranges
Dynamic Range
Measurement Range
Display Range
Reference Level Range
Attenuator Range
Amplitude Units
>95 dB (2.4 GHz), 2/3 (TOI-DANL) in 10 Hz RBW
DANL to +26 dBm
1 to 15 dB/div in 1 dB steps, ten divisions displayed
-130 dBm to +30 dBm
0 to 55 dB, 5.0 dB steps
Log Scale Modes: dBm, dBV, dBmv, dBμV
Linear Scale Modes: nV, μV, mV, V, kV, nW, μW, mW, W, kW
Amplitude Accuracy
100 kHz to 4.0 GHz
±1.25 dB, ±0.5 dB typical
>4.0 GHz to 6 GHz
±1.50 dB, ±0.5 dB typical
Displayed Average Noise Level (DANL)
Preamp Off
(Reference level -20 dBm)
(RBW Normalized to 1 Hz, 0 dB attenuation)
Maximum
Preamp On
(Reference level -50 dBm)
Typical
Maximum
Typical
10 MHz to 2.4 GHz
-141 dBm
146 dBm
-157 dBm
-162 dBm
>2.4 GHz to 4 GHz
-137 dBm
-141 dBm
-154 dBm
-159 dBm
>4 GHz to 5 GHz
-134 dBm
-138 dBm
-150 dBm
-155 dBm
> 5 GHz to 6 GHz
-126 dBm
-131 dBm
-143 dBm
-150 dBm
10 MHz to 2.4 GHz
-131 dBm
136 dBm
-147 dBm
-152 dBm
>2.4 GHz to 4 GHz
-127 dBm
-131 dBm
-144 dBm
-149 dBm
>4 GHz to 5 GHz
-124 dBm
-128 dBm
-140 dBm
-145 dBm
> 5 GHz to 6 GHz
-116 dBm
-121 dBm
-133 dBm
-140 dBm
(RBW = 10 Hz, 0 dB attenuation)
Spurs
Residual Spurious
Input-Related Spurious
Exceptions, typical
<-90 dBm (RF input terminated, 0 dB input attenuation, > 10 MHz)
<-75 dBc (0 dB attenuation, -30 dBm input, span <1.7 GHz, carrier offset >4.5 MHz)
<-70 dBc @ <2.5 GHz, with 2072.5 MHz Input
<-68 dBc @ F1-280 MHz with F1 Input
<-70 dBc @ F1 + 190.5 MHz with F1 Input
<-52 dBc @ 7349-2F2 MHz, with F2 Input, where F2 < 2424.5 MHz
<-55 dBc @ 190.5 ± F1/2 MHz, F1 <1 GHz
Third-Order Intercept (TOI)
Preamp Off (-20 dBm tones 100 kHz apart, 10 dB attenuation)
800 MHz
+16 dBm
2400 MHz
+20 dBm
200-2200 MHz
+25 dBm, typical
>2.2 GHz to 5.0 GHz
+28 dBm, typical
>5.0 GHz to 6.0 GHz
+33 dBm, typical
Second Harmonic Distortion
Preamp Off, 0 dB input attenuation, -30 dBm input
50 MHz
-56 dBc
>50 MHz to 200 MHz
-60 dBc, typical
>200 MHz to 3000 MHz
-70 dBc, typical
VSWR
2:1, typical
Page 5 of 16
Site Master™ S331E, S332E, S361E, S362E Specifications
2-Port Transmission Measurement (Option 0021)
Frequency
Frequency Range
Frequency Resolution
2 MHz to 4 GHz (S331E, S332E), 2 MHz to 6 GHz (S361E, S362E)
10 Hz
Output Power
High
0 dBm, typical
Low
-30 dBm, typical
Dynamic Range
2 MHz to 4 GHz
80 dB
>4 GHz to 6 GHz
70 dB
Application Options
Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)
Bias-Tee (Option 0010)
Setup
Voltage Range
Current (Low/High)
Resolution
On/Off, Voltage, Current (Low/High)
+12 to +32 V
250 mA/450 mA, 1 A surge for 100 ms
0.1 V
GPS Receiver Option (Option 0031) (Antenna sold separately, P/N 2000-1528-R)
Setup
GPS Time/Location Indicator
On/Off, Antenna Voltage 3.3/5.0 V, GPS Info
Time, Latitude, Longitude and Altitude on display
Time, Latitude, Longitude and Altitude with trace storage
High Frequency Accuracy
when GPS Antenna is connected
Connector
Spectrum Analyzer, Interference Analyzer, CW Signal Generator
<±50 ppb with GPS On, 3 minutes after satellite lock in selected mode
SMA, female
Optical Distance-to-Fault Module (P/N ODTF-1)
Wavelength
Fiber Type
1550 nm, typical
Single Mode Fiber
Event Resolution
10.2 cm (0.335 ft) maximum, or 150/(n*ΔF), ΔF in MHz, n is IOR
Horizontal Range
1020 meter (3345 ft) maximum, or (#dp-1)*Event Resolution
Optical Dynamic Range
Optical Output Power
RF Connector
Optical Connector
Datasheet
30 dB
3 dBm, typical
N(m)
FC/APC
11410-00478 (for complete specifications)
Page 6 of 16
Site Master™ S331E, S332E, S361E, S362E Specifications
Power Meter (Option 0029) (S332E, S362E)
Frequency
Center/Start/Stop, Span, Frequency Step, Signal Standard, Channel #, Full Band
Amplitude
Maximum, Minimum, Offset, Relative On/Off, Units, Auto Scale
Average
Limits
Frequency Range
Span
Display Range
Measurement Range
Offset Range
VSWR
Acquisition Fast/Med/Slow, # of Running Averages
Limit On/Off, Limit Upper/Lower
10 MHz to 4 GHz (S332E), 10 MHz to 6 GHz (S362E)
1 kHz to 100 MHz
-140 dBm to +30 dBm, ≤40 dB span
-120 dBm to +26 dBm
0 to +100 dB
2:1 typical
Maximum Power
+26 dBm without attenuator
Accuracy
Same as Spectrum Analyzer
Application Options
Impedance (50 Ω, 75 Ω, Other)
High Accuracy Power Meter (Option 0019) (Requires external USB Power Sensor(s))
Amplitude
Maximum, Minimum, Offset, Relative On/Off, Units, Auto Scale
Average
# of Running Averages, Max Hold
Zero/Cal
Zero On/Off, Cal Factor (Center Frequency, Signal Standard)
Limits
Power Sensor Model
Description
Limit On/Off, Limit Upper/Lower
PSN50
MA24104A
MA24106A
MA24108/18/26A
High Accuracy RF Power
Inline High Power Sensor
High Accuracy RF Power
Microwave USB Power
Sensor
Sensor
Sensor
Frequency Range
50 MHz to 6 GHz
600 MHz to 4 GHz
50 MHz to 6 GHz
Connector
Type N(m), 50 Ω
Type N(m), 50 Ω
Type N(m), 50 Ω
-30 to +20 dBm (.001 to
+3 to +51.76 dBm (2 mW to
-40 to +23 dBm
-40 to +20 dBm
100 mW)
150 W)
(0.1 µW to 200 mW)
(0.1 µW to 100 mW)
Dynamic Range
VBW
Measurand
10 MHz to 8 GHz
(MA24108A)
10 MHz to 18 GHz
(MA24118A)
10 MHz to 26 GHz
(MA24126A)
Type N(m), 50 Ω
(MA24108/18A)
Type K(m), 50 Ω
(MA24126A)
100 Hz
100 Hz
100 Hz
50 kHz
True-RMS
True-RMS
True-RMS
True-RMS,
Slot Power, Burst Average
Power
Measurement Uncertainty
±0.16 dB1
±0.17 dB2
±0.16 dB1
±0.18 dB3
Datasheet
(for complete specifications)
11410-00414
11410-00483
11410-00424
11410-00504
Notes:
1) T
otal RSS measurement uncertainty (0 ºC to 50 ºC) for power measurements of a CW signal greater than -20 dBm with zero mismatch errors.
2) Expanded uncertainty with K=2 for power measurements of a CW signal greater than +20 dBm with a matched load. Measurement
results referenced to the input side of the sensor.
3) Expanded uncertainty with K=2 for power measurements of a CW signal greater than -20 dBm with zero mismatch errors.
Page 7 of 16
Site Master™ S331E, S332E, S361E, S362E Specifications
Interference Analyzer (Option 0025) (S332E, S362E)
Measurements
Spectrum
Field Strength
Occupied Bandwidth
Channel Power
Adjacent Channel Power (ACPR)
AM/FM/SSB Demodulation (Wide/Narrow FM, Upper/Lower SSB), (audio out only)
Carrier-to-Interference ratio (C/I)
Spectrogram (Collect data up to one week)
Signal Strength (Gives visual and aural indication of signal strength)
Received Signal Strength Indicator (RSSI) (collect data up to one week)
Gives visual and aural indication of signal strength
Signal ID (up to 12 signals)
Center Frequency
Bandwidth
Signal Type (FM, GSM, W-CDMA, CDMA, Wi-Fi)
Closest Channel Number
Number of Carriers
Signal-to-Nose Ratio (SNR) >10 dB
Application Options
Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)
Channel Scanner (Option 0027) (S332E, S362E)
Number of Channels
Measurements
Scanner
Amplitude
Custom Scan
Frequency Range
1 to 20 Channels (Power Levels)
Graph/Table, Max Hold (On/5 sec/Off), Freq/Channel, Current/Max, Single/Dual Color
Scan Channels, Scan Frequencies, Scan Customer List, Scan Script Master™
Reference Level, Scale
Signal Standard, Channel, # of Channels, Channel Step Size, Custom Scan
100 kHz to 4 GHz (S332E), 100 kHz to 6 GHz (S362E)
Frequency Accuracy
±10 Hz + Time base error
Measurement Range
-110 dBm to +26 dBm
Application Options
Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)
CW Signal Generator Option (Option 0028) (S332E, S362E) (Requires CW Signal Generator Kit, P/N 69793)
Setup Parameters
Frequency
Frequency, Signal Standard, Channel Number, Display Setup Help
Amplitude
Power Level (Low/High), Offset (dB)
Frequency Range
Frequency Reference
Output Power
2 MHz to 2 GHz
Accuracy: ±1.5 ppm (25 °C ±25 °C) + aging, < ±50 ppb with GPS On
High 0 dBm typical, Low -30 dBm typical
Attenuator (included in kit 69793): 0 to 90 dB in 1 dB steps
Gated Sweep (Option 0090) (S332E, S362E)
Mode
Trigger
Setup
Spectrum Analyzer, Sweep
External TTL
Gated Sweep (On/Off)
Gate Polarity (Rising, Falling)
Gate Delay (0 to 65 ms typical)
Gate Length (1 µs to 65 ms typical)
Zero Span Time
Page 8 of 16
Site Master™ S331E, S332E, S361E, S362E Specifications
AM/FM/PM Signal Analyzers (Option 0509) (S332E, S362E)
Measurements
RF Spectrum
AM/FM/PM
Audio Spectrum
(AM)
Audio Spectrum
(FM/PM)
Audio
Waveform
(AM)
Audio
Waveform
(FM/PM)
Summary
(AM)
Summary
(FM/PM)
Graphic
Display
Power (dBm)
vs. Frequency
Depth (%)
vs. Modulation
Frequency
Deviation
(kHz/rad) vs.
Modulation
Frequency
Depth (%)
vs. Time
Deviation
(kHz/rad)
vs. Time
None
None
Numerical
Displays
Carrier Power
AM Rate
FM/PM Rate
AM Rate
FM/PM Rate
RMS Depth (AM)
Carrier Frequency
RMS Depth
RMS Deviation
RMS Depth
RMS Depth
Peak + Depth
RMS Deviation
(FM/PM)
Occupied
Bandwidth
(Pk-PK)/2 Depth
(Pk-PK)/2
Deviation
(Pk-PK)/2 Depth
(Pk-PK)/2 Depth
Peak – Depth
Peak + Depth
SINAD*
SINAD*
SINAD*
(Pk-PK)/2 Depth
Peak – Depth
THD*
SINAD*
THD*
THD*
Carrier Power
(Pk-PK)/2 Depth
Distortion/Total
Vrms*
THD*
Distortion/Total
Distortion/Total
Vrms*
Vrms*
Carrier
Frequency
Carrier Power
Distortion/Total
Vrms*
Occupied
Bandwidth
Carrier
Frequency
AM Rate
Occupied
Bandwidth
SINAD*
AM Rate
THD*
SINAD*
Distortion/Total
Vrms*
THD*
Distortion/Total
Vrms*
Setup Parameters
Frequency
Center Freq, Span, Freq Step, Signal Standard, Channel, Channel Increment,
Set Carrier Freq
Amplitude
Scale, Power Offset, Adjust Range
Setup
Measurements
Marker
Demod Type (AM, FM, PM), IFBW, Auto IFBW
RF Spectrum AM/FM/PM, Audio Spectrum (AM/FM/PM),
Audio Waveform (AM/FM/PM), Summary (AM/FM/PM)
On/Off, Delta, Peak Search, Marker Freq to Center, Marker to Ref Lvl, Marker Table,
All Markers Off
Specifications
AM
Modulation Rate: ±1 Hz (<100 Hz), ±2% (>100 Hz)
Depth: ±5% for (Modulation rates 10 Hz to 100 kHz)
FM
Modulation Rate: ±1 Hz (<100 Hz); ±2% (100 Hz to 100 kHz)
Deviation Accuracy: ±5% (100 Hz to 100 kHz)**
PM
Modulation Rate: ±1 Hz (<100 Hz); ±2% (100 Hz to 100 Hz)
Deviation Accuracy: ±5% (deviation 0 to 93 Rad, rate 10 Hz to 5 kHz)**
IF bandwidth
Frequency Span
1 to 300 kHz in 1-3 sequence
RF Spectrum: 10 kHz to 10 MHz
Audio Spectrum: 2, 5, 10, 20 kHz
RBW/VBW
30
Span/RBW
100
Sweep time
50 µs to 50 ms (Audio Waveform)
* Requires Sinewave modulation
** IFBW must be greater than 95% occupied BW
Page 9 of 16
Site Master™ S331E, S332E, S361E, S362E Specifications
All specifications and characteristics apply under the following conditions, unless otherwise stated: 1) After 5 minutes of warm-up time, where
the instrument is left in the ON state; 2) All specifications apply when using internal reference; 3) All specifications subject to change without
notice; 4) Typical performance is the measured performance of an average unit; 5) Recommended calibration cycle is 12 months.
General Specifications
Setup Parameters
System
Status (Temperature, Battery Info, Serial Number, Firmware Version, Options Installed)
Self Test, Application Self Test
GPS (see Option 0031)
System Options
Name, Date and Time, Volume, Display (Brightness, Default Colors, Black & White, Night Vision,
High Contrast),
Language (English, French, German, Spanish, Chinese, Japanese, Korean, Italian, User defined)
Reset (Factory Defaults, Master Reset, Update Firmware)
File
Save/Recall
Delete
Directory Management
Save, Recall, Delete, Directory Management
Setups, Measurements, Screen Shots Jpeg (save only)
Selected File, All Measurements, All Mode Files, All Content
Sort Method (Name/Type/Date), Ascend/Descend, Internal/USB, Copy, Format USB
Internal Trace/Setup Memory
2,000 traces, 2,000 Setups
External Trace/Setup Memory
Limited by size of USB Flash drive
Mode Switching
Auto-Stores/Recalls most recently used Setup Parameters in the Mode
Connectors
RF Out
RF Out Damage Level
RF In
RF In Damage Level
GPS
External Power
USB Interface (2)
USB Interface
Headset Jack
External Reference In
Type N, female, 50 Ω (Reflection In) (Option 21 only)
23 dBm, ±50 VDC (Option 21 only)
Type N, female, 50 Ω
+35 dBm peak, ±50 VDC, Maximum Continuous Input (≥10 dB attenuation)
SMA(f)
5.5 mm barrel connector, 12.5 to 15 VDC, < 4.0 Amps
Type A, Connect USB Flash Drive and Power Sensor
5-pin mini-B, Connect to PC for data transfer
2.5 mm mini-phone plug
BNC, female, 50 Ω, Maximum Input +10 dBm
1 MHz, 5 MHz, 10 MHz, 13 MHz
External Trigger/Clock Recovery
BNC, female, 50 Ω, Maximum Input ±50 VDC
Display
Type
Resistive Touchscreen
Size
8.4” daylight viewable color LCD
Resolution
800 x 600
Battery
Type
Battery Operation
Li-Ion
4.0 hours, typical (S331E, S361E)
3.0 hours, typical (S332E, S362E)
Electromagnetic Compatibility
European Union
CE Mark, EMC Directive 89/336/EEC, 92/31/EEC, 93/68/EEC and
Low Voltage Directive 73/23/EEC, 93/68/EEC
Australia and New Zealand
C-tick N274
Interference
EN 61326-1
Emissions
EN 55011
Immunity
EN 61000-4-2/-4-3/-4-4/-4-5/-4-6/-4-11
Safety
Safety Class
Product Safety
EN 61010-1 Class 1
IEC 60950-1 when used with Company supplied Power Supply
Environmental
Operating Temperature
Maximum Humidity
Shock
-10 ºC to 55 ºC
85%
MIL-PRF-28800F Class 2
Storage
-40 ºC to 71 ºC
Altitude
4600 meters, operating and non-operating
Size and Weight
Size
Weight
273 x 199 x 91 mm, (10.7 x 7.8 x 3.6 in)
2.71 kg, (6.0 lbs), (S331E, S361E)
3.71 kg, (8.2 lbs), (S332E, S362E)
Page 10 of 16
Site Master™ S331E, S332E, S361E, S362E Specifications
Master Software Tools (for your PC)
Database Management
Full Trace Retrieval
Trace Catalog
Trace Rename Utility
Group Edit
DAT File Converter
Retrieve all traces from instrument into one PC directory
Index all traces into one catalog
Rename measurement traces
Title, subtitles, plot scaling, markers and limit lines, simultaneously on similar files
Converts HHST files to MST file format and vice-versa
Data Analysis
Trace Math and Smoothing
Data Converter
Measurement Calculator
Compare multiple traces
Convert from/to Return Loss, VSWR, Cable Loss, DTF and also into Smith Charts
Translates into other units
Report Generation
Report Generator
Includes GPS, power level, and calibration status along with measurements
Edit Graph
Change scale, limit lines, and markers
Report Format
Create reports in HTML for PDF format
Export Measurements
Notes
Export measurements to *.s2p, *.jpg or *.csv format
Annotate measurements
Mapping (GPS Required)
Spectrum Analyzer Mode
MapInfo, MapPoint
Folder Spectrogram (Spectrum Monitoring for Interference Analysis and Spectrum Clearing)
Folder Spectrogram – 2D View
Creates a composite file of multiple traces
Peak Power, Total Power, Peak Frequency, Histogram, Average Power (Max/Min)
File Filter (Violations over limit lines or deviations from averages)
Playback
Video Folder Spectrogram – 2D View
Folder Spectrogram – 3D View
Create AVI file to export for management review/reports
Views (Set Threshold, Markers)
- 3D (Rotate X, Y, Z Axis, Level Scale, Signal ID)
- 2D View (Frequency or Time Domain, Signal ID)
- Top Down
Playback (Frequency and/or Time Domain)
List/Parameter Editors
Traces
Antennas, Cables, Signal Standards
Add, delete, and modify limit lines and markers
Modify instrument’s Antenna, Cable, and Signal Standard List
Product Updates
Auto-checks Anritsu website for latest revision firmware
Firmware Upload
Upload new firmware into the instrument
Languages
Display
Add up to two languages and modify non-English language menus
Modify display settings
Script Master™
Channel Scanner Mode
Automate scan up to 1200 channels, repeat for sets of 20 channels, repeat all channels
Connectivity
Connections
Download
Upload
Firmware Updates
Connect to PC using USB
Download measurements and live traces to PC for storage and analysis
Upload measurements from PC to instrument
Create USB Flash Drive for firmware update
Page 11 of 16
Site Master™ S331E, S332E, S361E, S362E Specifications
Ordering Information – Options
S331E
S332E
S361E
S362E
2 MHz to 4 GHz
2 MHz to 4 GHz
2 MHz to 6 GHz
2 MHz to 6 GHz
Cable and Antenna Analyzer
100 kHz to 6 GHz
Spectrum Analyzer
100 kHz to 4 GHz
Description
Options
Options
Options
Options
S331E-0021
S332E-0021
S361E-0021
S362E-0021
2-Port Transmission Measurement
S331E-0010
S332E-0010
S361E-0010
S362E-0010
Bias-Tee (Requires Option 0021 for S331E /S361E)
S331E-0031
S332E-0031
S361E-0031
S362E-0031
GPS Receiver (Requires Antenna P/N 2000-1528-R)
S331E-0019
S332E-0019
S361E-0019
S362E-0019
High-Accuracy Power Meter
S332E-0029
S362E-0029
Power Meter
S332E-0025
S362E-0025
Interference Analyzer
S332E-0027
S362E-0027
Channel Scanner
S332E-0090
S362E-0090
Gated Sweep
S332E-0028
S362E-0028
C/W Signal Generator (Requires CW Signal Generator Kit, P/N 69793)
S332E-0509
S362E-0509
AM/FM/PM Analyzer
S331E-0098
S332E-0098
S361E-0098
S362E-0098
Standard Calibration (ANSI 2540-1-1994)
S331E-0099
S332E-0099
S361E-0099
S362E-0099
Premium Calibration (ANSI 2540-1-1994 plus test data)
Power Sensors (For complete ordering information see the respective datasheets of each sensor)
Model Number
PSN50
Description
High Accuracy RF Power Sensor, 50 MHz to 6 GHz, +20 dBm
MA24104A
Inline High Power Sensor, 600 MHz to 4 GHz, +51.76 dBm
MA24106A
High Accuracy RF Power Sensor, 50 MHz to 6 GHz, +23 dBm
MA24108A
Microwave USB Power Sensor, 10 MHz to 8 GHz, +20 dBm
MA24118A
Microwave USB Power Sensor, 10 MHz to 18 GHz, +20 dBm
MA24126A
Microwave USB Power Sensor, 10 MHz to 26 GHz, +20 dBm
Manuals (soft copy included on MST CD and at www.us.anritsu.com)
Part Number
Description
10580-00252
Site Master User Guide (Hard copy included)
10580-00241
Cable and Antenna Analyzer Measurement Guide
10580-00242
2-Port Transmission Measurement
- Bias-Tee
10580-00231
Spectrum Analyzer Measurement Guide
- Interference Analyzer, Channel Scanner, Gated Sweep,
CW Signal Generator, AM/FM/PM Analyzer
10580-00240
Power Meter Measurement Guide
- High Accuracy Power Meter
10580-00215
ODTF-1 Optical Distance-to-Fault Module
10580-00256
Programming Manual
Standard Accessories (included with instrument)
Part Number
10580-00252
3-68736
2300-498
633-44
40-168-R
806-141-R
Description
Site Master User Guide
Soft Carrying Case
MST CD: Master Software Tools, User/Measurement Guides,
Programming Manual, Troubleshooting Guides, Application Notes
Rechargeable Li-Ion Battery
AC-DC Adapter
Automotive Cigarette Lighter 12 VDC Adapter
3-2000-1498
USB A/5-pin mini-B Cable, 10 feet/305 cm
11410-00484
Site Master™ S331E, S332E, S361E, S362E Technical Data Sheet
One Year Warranty (Including battery, firmware, and software)
Certificate of Calibration and Conformance
Page 12 of 16
Site Master™ S331E, S332E, S361E, S362E Specifications
Optional Accessories
Calibration Components, 50 Ω
Part Number
ICN50B
Description
InstaCal™ Calibration Module, 38 dB, 2 MHz to 6.0 GHz, N(m), 50 Ω
OSLN50-1
Precision Open/Short/Load, N(m), 42 dB, 6.0 GHz, 50 Ω
OSLNF50-1
Precision Open/Short/Load, N(f), 42 dB, 6.0 GHz, 50 Ω
2000-1618-R
Precision Open/Short/Load, 7/16 DIN(m), DC to 6.0 GHz 50 Ω
2000-1619-R
Precision Open/Short/Load, 7/16 DIN(f), DC to 6.0 GHz 50 Ω
22N50
Open/Short, N(m), DC to 18 GHz, 50 Ω
22NF50
Open/Short, N(f), DC to 18 GHz, 50 Ω
SM/PL-1
Precision Load, N(m), 42 dB, 6.0 GHz, 50 Ω
SM/PLNF-1
Precision Load, N(f), 42 dB, 6.0 GHz, 50 Ω
Calibration Components, 75 Ω
22N75
Open/Short, N(m), DC to 3 GHz, 75 Ω
22NF75
Open/Short, N(f), DC to 3 GHz, 75 Ω
26N75A
Precision Termination, N(m), DC to 3 GHz, 75 Ω
26NF75A
Precision Termination, N(f), DC to 3 GHz, 75 Ω
12N50-75B
Matching Pad, DC to 3 GHz, 50 Ω to 75 Ω
Phase-Stable Test Port Cables, Armored w/ Reinforced Grip (recommended for cable & antenna line sweep applications)
15RNFN50-1.5-R
1.5 m, DC to 6 GHz, N(m) - N(f), 50 Ω
15RDFN50-1.5-R
1.5 m, DC to 6 GHz, N(m) - 7/16 DIN(f), 50 Ω
15RDN50-1.5-R
1.5 m, DC to 6 GHz, N(m) - 7/16 DIN(m), 50 Ω
15RNFN50-3.0-R
3.0 m, DC to 6 GHz, N(m) - N(f), 50 Ω
15RDFN50-3.0-R
3.0 m, DC to 6 GHz, N(m) - 7/16 DIN(f), 50 Ω
15RDN50-3.0-R
3.0 m, DC to 6 GHz, N(m) - 7/16 DIN(m), 50 Ω
Phase-Stable Test Port Cables, Armored (recommended for use with tightly spaced connectors and other general purpose applications)
15NNF50-1.5C
1.5 m, DC to 6 GHz, N(m) - N(f), 50 Ω
15NN50-1.5C
1.5 m, DC to 6 GHz, N(m) - N(m), 50 Ω
15NDF50-1.5C
1.5 m, DC to 6 GHz, N(m) - 7/16 DIN(f), 50 Ω
15ND50-1.5C
1.5 m, DC to 6 GHz, N(m) - 7/16 DIN(m), 50 Ω
15NNF50-3.0C
3.0 m, DC to 6 GHz, N(m) - N(f), 50 Ω
15NN50-3.0C
3.0 m, DC to 6 GHz, N(m) - N(m), 50 Ω
Adapters
1091-26-R
SMA(m) - N(m), DC to 18 GHz, 50 Ω
1091-27-R
SMA(f) - N(m), DC to 18 GHz, 50 Ω
1091-80-R
SMA(m) - N(f), DC to 18 GHz, 50 Ω
1091-81-R
SMA(f) - N(f), DC to 18 GHz, 50 Ω
1091-172
BNC(f) - N(m), DC to 1.3 GHz, 50 Ω
510-90
7/16 DIN(f) - N(m), DC to 7.5 GHz, 50 Ω
510-91
7/16 DIN(f) - N(f), DC to 7.5 GHz, 50 Ω
510-92
7/16 DIN(m) - N(m), DC to 7.5 GHz, 50 Ω
510-93
7/16 DIN(m) - N(f), DC to 7.5 GHz, 50 Ω
510-96
7/16 DIN(m) - 7/16 DIN (m), DC to 7.5 GHz, 50 Ω
510-97
7/16 DIN(f) - 7/16 DIN (f), DC to 7.5 GHz, 50 Ω
1091-379-R
510-102-R
7/16 DIN(f) - 7/16 DIN(f), DC to 6 GHz, 50 Ω, w/ Reinforced Grip
N(m) - N(m), DC to 11 GHz, 50 Ω, 90 degrees right angle
Precision Adapters
34NN50A
34NFNF50
Precision Adapter, N(m) - N(m), DC to 18 GHz, 50 Ω
Precision Adapter, N(f) - N(f), DC to 18 GHz, 50 Ω
Miscellaneous Accessories
2000-1528-R
69793
ODTF-1
2000-1520-R
2000-1374
Page 13 of 16
GPS Antenna, SMA(m)
CW Signal Generator Kit
Optical Distance-to-Fault Module, 1550 nm, Single Mode
USB Flash Drive
External Charger for Li-lon Batteries
Site Master™ S331E, S332E, S361E, S362E Specifications
Optional Accessories (continued)
Backpack and Transit Case
67135
760-243-R
Anritsu Backpack (For Handheld Instrument and PC)
Large Transit Case with Wheels and Handle
Directional Antennas
Part Number
Description
2000-1411-R
822-900 MHz, N(f), 10 dBd, Yagi
2000-1412-R
885-975 MHz, N(f), 10 dBd, Yagi
2000-1413-R
1710-1880 MHz, N(f), 10 dBd. Yagi
2000-1414-R
1850-1990 MHz, N(f), 9.3 dBd, Yagi
2000-1415-R
2400-2500 MHz, N(f), 10 dBd, Yagi
2000-1416-R
1920-2170 MHz, N(f), 10 dBd, Yagi
2000-1519
500 MHz to 3 GHz, log periodic
2000-1200
806-866 MHz, SMA(m), 50 Ω
2000-1473
870-960 MHz, SMA(m), 50 Ω
2000-1035
896-941 MHz, SMA (m), 50 Ω (1/4 wave)
2000-1030
1710 to 1880 MHz, SMA(m), 50 Ω (1/2 wave)
2000-1474
1710 to 1880 MHz with knuckle elbow (1/2 wave)
2000-1031
1850 to 1990 MHz, SMA(m), 50 Ω (1/2 wave)
2000-1475
1920 to 1980 MHz and 2110 to 2170 MHz, SMA(m), 50 Ω
Portable Antennas
2000-1032-R
2000-1361
61532
2400 to 2500 MHz, SMA(m), 50 Ω (1/2 wave)
2400 to 2500, 5000 to 6000 MHz, SMA(m), 50 Ω
Antenna Kit (Consists of: 2000-1030, 2000-1031, 2000-1032-R,
2000-1200, 2000-1035, 2000-1361, and carrying pouch)
Bandpass Filters
1030-114-R
806-869 MHz, N(m) - SMA(f), 50 Ω
1030-109-R
824 - 849 MHz, N(m) - SMA (f), 50 Ω
1030-110-R
880 - 915 MHz, N(m) - SMA (f), 50 Ω
1030-105-R
890-915 MHz Band, 0.41 dB loss, N(m) - SMA(f), 50 Ω
1030-111-R
1850 - 1910 MHz, N(m) - SMA (f), 50 Ω
1030-106-R
1710-1790 MHz Band, 0.34 dB loss, N(m) - SMA(f), 50 Ω
1030-107-R
1910-1990 MHz Band, 0.41 dB loss, N(m) - SMA(f), 50 Ω
1030-112-R
2400 - 2484 MHz, N(m) - SMA (f), 50 Ω
1030-155-R
2500-2700 MHz, N(m) – N(f), 50 Ω
3-1010-122
20 dB, 5 W, DC to 12.4 GHz, N(m)-N(f)
42N50-20
20 dB, 5 W, DC to 18 GHz, N(m) - N(f)
42N50A-30
30 dB, 5 W, DC to 18 GHz, N(m) - N(f)
3-1010-123
30 dB, 50 W, DC to 8.5 GHz, N(m)-N(f)
1010-127-R
30 dB, 150 W, DC to 3 GHz, N(m) - N(f)
3-1010-124
40 dB, 100 W, DC to 8.5 GHz, N(m)-N(f), Uni-directional
Attenuators
1010-121
1010-128-R
Page 14 of 16
40 dB, 100 W, DC to 18 GHz, N(m)-N(f), Uni-directional
40 dB, 150 W, DC to 3 GHz, N(m) - N(f)
Site Master™ S331E, S332E, S361E, S362E Specifications
Notes
Page 15 of 16
The Master Users Group is an organization dedicated to providing training, technical support, networking opportunities
and links to Master product development teams. As a member you will receive the Insite Quarterly Newsletter with user
stories, measurement tips, new product news and more.
Visit us to register today: www.anritsu.us/smiusignup
To receive a quote to purchase a product or order accessories visit our online ordering site: www.ShopAnritsu.com
Training at Anritsu
Anritsu has designed courses to help you stay up to date with technologies important to your job.
For available training courses visit: www.us.anritsu.com/training
Anritsu Corporation
5-1-1 Onna, Atsugi-shi, Kanagawa, 243-8555 Japan
Phone: +81-46-223-1111
Fax: +81-46-296-1264
• U.S.A.
Anritsu Company
Borgafjordsgatan 13, 164 40 Kista, Sweden
Phone: +46-8-534-707-00
Fax: +46-8-534-707-30
• Finland
Anritsu AB
• Canada
Anritsu Electronics Ltd.
700 Silver Seven Road, Suite 120, Kanata,
Ontario K2V 1C3, Canada
Phone: +1-613-591-2003
Fax: +1-613-591-1006
• Brazil
Anritsu Electrônica Ltda.
Teknobulevardi 3-5, FI-01530 Vantaa, Finland
Phone: +358-20-741-8100
Fax: +358-20-741-8111
• Denmark
Anritsu A/S
Kirkebjerg Allé 90 DK-2605 Brøndby, Denmark
Phone: +45-72112200
Fax: +45-72112210
Praca Amadeu Amaral, 27-1 Andar
01327-010 - Paraiso, São Paulo, Brazil
Phone: +55-11-3283-2511
Fax: +55-11-3288-6940
• Spain
Anritsu EMEA Ltd.
Oficina de Representación en España
• Mexico
Anritsu Company, S.A. de C.V.
Av. Ejército Nacional No. 579 Piso 9, Col. Granada
11520 México, D.F., México
Phone: +52-55-1101-2370
Fax: +52-55-5254-3147
• U.K.
Anritsu EMEA Ltd.
200 Capability Green, Luton, Bedfordshire LU1 3LU, U.K.
Phone: +44-1582-433200
Fax: +44-1582-731303
• France
Anritsu S.A.
16/18 Avenue du Québec-SILIC 720
91961 COURTABOEUF CEDEX, France
Phone: +33-1-60-92-15-50
Fax: +33-1-64-46-10-65
Nemetschek Haus, Konrad-Zuse-Platz 1
81829 München, Germany
Phone: +49 (0) 89 442308-0
Fax: +49 (0) 89 442308-55
Via Elio Vittorini, 129, 00144 Roma, Italy
Phone: +39-06-509-9711
Fax: +39-06-502-2425
• Sweden
Anritsu AB
1155 East Collins Boulevard, Suite 100,
Richardson, Texas 75081 U.S.A.
Toll Free: 1-800-ANRITSU (267-4878)
Phone: +1-972-644-1777
Fax: +1-972-671-1877
• Germany
Anritsu GmbH
• Italy
Anritsu S.p.A.
Edificio Veganova
Avda de la Vega, n 1 (edf 8, pl1, of 8)
28108 ALCOBENDAS - Madrid, Spain
Phone: +34-914905761
Fax: +34-914905762
o
• Russia
Anritsu EMEA Ltd.
Representation Office in Russia
Tverskaya str. 16/2, bld. 1, 7th floor.
Russia, 125009, Moscow
Phone: +7-495-363-1694
Fax: +7-495-935-8962
• United Arab Emirates
Anritsu EMEA Ltd.
Dubai Liaison Office
P O Box 500413 - Dubai Internet City
Al Thuraya Building, Tower 1, Suite 701, 7th Floor
Dubai, United Arab Emirates
Phone: +971-4-3670352
Fax: +971-4-3688460
• Singapore
Anritsu Pte. Ltd.
60 Alexandra Terrace, #02-08, The Comtech (Lobby A)
Singapore 118502
Phone: +65-6282-2400
Fax: +65-6282-2533
• India
Anritsu Pte. Ltd.
India Branch Office
3rd Floor, Shri Lakshminarayan Niwas,
#2726, 80 ft Road, HAL 3rd Stage, Bangalore - 560 075, India
Phone: +91-80-4058-1300
Fax: +91-80-4058-1301
• P. R. China (Hong Kong)
Anritsu Company Ltd.
Units 4 & 5, 28th Floor, Greenfield Tower, Concordia Plaza,
No. 1 Science Museum Road, Tsim Sha Tsui East,
Kowloon, Hong Kong, P.R. China
Phone: +852-2301-4980
Fax: +852-2301-3545
• P. R. China (Beijing)
Anritsu Company Ltd.
Beijing Representative Office
Room 2008, Beijing Fortune Building,
No. 5 , Dong-San-Huan Bei Road,
Chao-Yang District, Beijing 100004, P.R. China
Phone: +86-10-6590-9230
Fax: +86-10-6590-9235
• Korea
Anritsu Corporation, Ltd.
8F Hyunjuk Bldg. 832-41, Yeoksam-Dong,
Kangnam-ku, Seoul, 135-080, Korea
Phone: +82-2-553-6603
Fax: +82-2-553-6604
• Australia
Anritsu Pty Ltd.
Unit 21/270 Ferntree Gully Road, Notting Hill
Victoria, 3168, Australia
Phone: +61-3-9558-8177
Fax: +61-3-9558-8255
• Taiwan
Anritsu Company Inc.
7F, No. 316, Sec. 1, Neihu Rd., Taipei 114, Taiwan
Phone: +886-2-8751-1816
Fax: +886-2-8751-1817
®Anritsu All trademarks are registered trademarks of Technical Data Sheet No. 11410-00484, Rev. B Printed in United States 2010-01
their respective companies. Data subject to change
©2010 Anritsu Company. All Rights Reserved.
without notice. For the most recent specifications visit:
www.us.anritsu.com
Open as PDF
Similar pages