User Manual of G18 GSM Alarm System
Operation Instruction
User Manual of G18
GSM Alarm System
Version 1.0
2015.07
Reading carefully before handle
Keeping the user manual reserved
Table of Contents
Chapter One Introduction ...................................................................................03
1.1 System Introduction .....................................................................................03
1.2 Function Introduction ..................................................................................03
Chapter Two Host Installation ..............................................................................04
Chapter Three Operation&Setting......................................................................05
3.1 Initial Power-on .............................................................................................05
3.2 Arm.................................................................................................................05
3.3 Disarm ...........................................................................................................05
3.4 Home Arm .....................................................................................................05
3.5 Emergency Alarm ........................................................................................06
3.6 Set Phone No. ...............................................................................................06
3.6.1 Set Alarm Phone No. ..............................................................................06
3.6.2 Set CID No...............................................................................................07
3.6.3 Set Help Phone No. ................................................................................07
3.6.4 Set SMS Phone No. .................................................................................07
3.6.5 Phone Call ..............................................................................................07
3.7 Accessories...................................................................................................08
3.7.1 Add Remote Control.................................................................................08
3.7.2 Delete Remote Control .........................................................................08
3.7.3 Add Detectors ........................................................................................08
3.7.4 Delete Detectors....................................................................................09
3.7.5 Intelligent Accessories ..........................................................................09
3.7.5.1 Code Match between Host & Wireless Strobe Siren ....................09
3.7.5.2 Code Match between Host and Smart Socket ............................10
3.8.1 Delay Set ..................................................................................................10
3.8.1.1 Delay Arm Set.................................................................................10
3.8.1.2 Delay Alarm Set ..............................................................................10
3.8.2 Password Se .............................................................................................11
3.8.2.1 System Password..............................................................................11
3.8.2.2 Keypad Password ............................................................................11
3.8.3 Voice Setting ...........................................................................................11
3.8.3.1 System Volume ................................................................................11
3.8.3.2 System Voice....................................................................................12
3.8.4 Siren Setting .............................................................................................12
3.8.4.1 Internal Siren Volume ......................................................................12
3.8.4.2 Siren Alarm Timet .............................................................................12
3.8.5 Phone Message Setting...........................................................................12
3.8.5.1 Message Reply ................................................................................12
3.8.5.2 Alarm Output.....................................................................................12
3.8.6 Alarm Output ...............................................................................................13
3.8.7 Scheduled Arm/Disarm .........................................................................13
3.8.8 Scheduled Arm/Disarm .........................................................................13
3.8.8.1 User Area Code.................................................................................13
3.8.8.2 Arm/Disarm Upload ..........................................................................13
3.8.8.3 Self Test Time .....................................................................................13
3.8.8.4 Self Test Week ....................................................................................14
3.8.9 Low Batter y and Anti-tamper Setting ...................................................14
3.8.9.1 Back Light Power Saving...................................................................14
3.8.9.2 Anti-tamper Switch ...........................................................................14
3.8.9.3 Illegal Arm .........................................................................................14
3.8.9.4 Power Off Setting ..............................................................................14
3.8.10 Restore Factor y Setting .......................................................................15
3.8.10.1 Partial Restoration ..........................................................................16
3.8.10.2 Full Restoration ..............................................................................16
3.9 Recording Setting.........................................................................................16
3.10 Zone Management ...................................................................................16
3.10.1 Network Even Code .............................................................................16
3.10.2 Internal Siren On/off.............................................................................16
3.10.3 Set Zone Type ......................................................................................16
3.10.4 Set Sub Zone Dialing............................................................................16
3.11 Clock Management ..................................................................................16
3.12 Check Records ..........................................................................................17
3.12.1 Alarm Records......................................................................................17
3.12.2 Arm/Disarm Records............................................................................17
3.13 Check Product Version ..............................................................................17
Chapter Four SMS Setting and Command Chart .............................................18
Chapter Five APP...................................................................................................20
5.1 App Downloading ........................................................................................20
5.2 Add Host Account ........................................................................................21
5.3 Operation Method .......................................................................................21
Chapter Six Receiving Alarms and Remote Control .........................................22
6.1 Handing method after receiving alarm: ...................................................22
6.2 Remote control operation method............................................................23
Chapter Seven Technical Parameters................................................................23
7.1 Technical Parameters ..................................................................................23
7.2 Factor y default zone type ...........................................................................23
7.3 System factor y default ................................................................................24
Chapter Eight Install Detectors ...........................................................................24
8.1 Installation and Usage of Door Sensor ..........................................................24
8.2 Installation and Use of PIR Motion Detector...................................................25
Chapter Nine Troubleshooting ............................................................................26
Chapter One Introduction
1.1 System Introduction
This alarm system is a high-end GSM alarm with stable and reliable performance
and applies 1.7-inch TFT color screen and touch keyboard with built-in powerful
CPU master and excellent operation experience. Automatic voice prompt or SMS
message notify the location and events upon alarm. Compatible with wireless
PIR sensor, door sensor, smoke detector, gas detector, panic button etc. It has
been widely used in home, factor y, school, shop, villa and residential area to
provide protection for valuable assets.
Chapter Two Host Installation
Host should be installed in the central position of the guard area to receive the
signals from detectors best. Keep away from large mental objects or appliances
with high frequency interference, meanwhile, avoid the reinforced concrete
walls and fire doors barriers etc.
1.2 Function Introduction
TFT color display, humanized menu, operation with voice prompt, easy to use
There are 99 zones and 8 zone types optional in each zone; ON/OFF siren in
each zone is available.
4 sets scheduled arm/disarm/stay arm function by zone/day/time.
6 groups alarm phone No., automatically dial preset phone number when
power failure.
Key Arm
Key Disarm
Power Base
DC-5V
Wireless study 1527 series accessories, and as much as 99 detectors and
remote controls.
ON/OFF
ON/OFF
10s automatic message recording with built-in artificial voice, so that user can
know the alarm place and zone when receive the alarm call remotely.
Arm/Disarm, Monitor, Speaker, siren ON/OFF, smart socket ON/OFF remotely.
Host Front View
Key Back
Telephone/SMS message long-distance control for arming, disarming,
monitoring, remote announcement.
Key Confirm
APP control host set and administration, and supports IOS/Android.
Host can call other phones directly as a common phone
One-way alarm linkage wireless relay, and one-way wireless strobe siren
Integrate high precision clock chip so that time never lost even power failure.
Display the latest 72 arm/disarm and 102 alarm records
SIM Card Base
Key Menu
Host Keypad and Side View
2 groups of CID number. Compatible with international alarm networking
protocol Contact ID
Low-voltage indication and anti-tamper
Built-in rechargeable high capacity LI batter y and supply power automatically
when power supply failure
Tamper Button
Caller ID display, power-off reminder.
SIM
Host applies four frequency GSM/GPRS module
Host Back View
■ Prompt
Display ”Disarm”
Host is disarming
Display ”Arm”
Host is arming
Display ”Home Arm”
Host is home arming
TFT color Display ”XX Zone is alarmings”
display
detectors should be changed to be Home Arm zones in order to work properly.
After Home Arm operation, it displays and locks “ Home Arm” icon.
Remote Control operation: press key [STAY].
Keyboard operation: press key [ARM] twice
Host is alarming with specific defense zone
Display ”97 Zone is alarmings”
97 Zone is alarmed by tampering or
moving the Host. Anti-tamper alarm.
SIM icon is blinking
Host did not detect SIM card
Chapter Three Operation&Setting
3.5 Emergency Alarm
When an emergency occurs, press panic key on the remote control to enter
emergency alarm state.
Note: if the host password keyboard protection function is turned on, the password
needs to be input before the operation to the keyboard, and the initial password
is 1234.
3.1 Initial Power-on
According to the installation method, insert the SIM card to the card slot of the
host panel, then connect host with power and long press [ON/OFF] button. Now
then, host voice prompts “ Welcome to smart voice alarm”. At the same time the
host starts self-testing GSM network, "GSM signal LED" flashing (flash once for 1S)
when searching the GSM Signal.Until network working properly, SIM Card icon will
disappear, means GSM signals and SIM card working normal. If it keep flashing
means not detecting SIM card or something is wrong with SIM card.
Arm
Disarm
Stay
Emergency
3.2 Arm
Arm refers to a full range of on-site alarm detection alert when nobody at home;
All detectors are in working state, when there is danger ( theft, fire, gas leak etc )
trigger the detectors, the host alarms immediately. After arming operation, it
displays and locks “ARM” icon.
Remote Control operation: press key [ARM] once.
Keyboard operation: press key [ARM] once.
3.3 Disarm
Disarm refers to host panel stops the alarm or make the alarm system in a nonalert state. After disarming, when detectors are triggered, but host doesn’t alarm
(except the detectors of emergency zones and the emergency button on remote
control). After disarming operation, it displays and locks “Disarm” icon.
Remote Control operation: press key [Disarm].
Keyboard operation: press key [Disarm].
3.6 Set Phone No.
The host can maximum set 6 groups alarm No., 2 groups CID No., 3 groups Help
No., 6 groups SMS message No. The maximum length of evey group phone No.
is 30 digits. Please find settings as below:
Number Settings
16:
30
13-11-08 THU
Arming
OK.Enter
ESC. Return
OK.Enter
ESC. Return
ESC.返回
3.4 Home Arm
Home Arm refers to when someone at home, and for safety, the detectors in the
perimeter area like doors, windows, balconies are in working state but the detectors
indoor don’t work in case of the false alarm if triggered by user himself, then the
user chooses Home Arm to let some detectors work and other detectors not work.
Home Arm function needs to be set that is the defense zones of the interior
Number Settings
1.Alarm numbers
2.CID numbers
3.Help numbers
4.SMS numbers
5.Voice calls
Picture 3-1
3.6.1 Set Alarm Phone No.
As shown in picture 3-1, press key【UP/DOWN】to select 【1. Alarm Phone No.】
and press key【OK】 or input 1, then input group number (1-6), then input phone
number like 13812345678. User can set 6 groups alarm phone numbers at most.
Then press key 【BACK】to return to desk page.
Delete Alarm Phone No.
As shown in picture 3-1, after entering to the settings of alarm phone numbers,
press key 【Menu】 to delete the alarm phone number and press key【OK】to
save, then press key【BACK】to return to desk page.
3.7 Accessories
Add Accessories
1.Add Remote Control
2.Add Detector
3.Del Remote Control
4.Delete Detector
5.Smart Accessories
OK.Enter
3.6.2 Set CID No.
As shown in picture 3-1, press key【UP/DOWN】to select 【2. CID No.】and press
key【OK】or input 2, then input group number (1-2), then input CID number like
88889999 and press key 【OK】to save. Then press key 【BACK】to return to desk
page.
Delete CID No.
As shown in picture 3-1, after entering to the settings of CID numbers, press key
【Menu】 to delete all the CID No. and press key【OK】 to save, then press key
【BACK】to return to desk page.
3.6.3 Set Help Phone No.
As shown in picture 3-1, press key【UP/DOWN】to select【3. Help Phone No.】
and press key【OK】 or input 3, then input group number (1-3), then input phone
number like 13812345678 press key【OK】 to save. User can set 3 groups alarm
phone numbers at most. Then press key【BACK】to return to desk page.
Delete Help Phone No.
As shown in picture 3-1, after entering to the settings of Help Phone No., press key
【Menu】 to delete Help Phone No. and press key【OK】 to save, then press key
【BACK】to return to desk page.
3.6.4 Set SMS Phone No.
As shown in picture 3-1, press key【UP/DOWN】to select 【4. SMS Phone No.】and
press key【 OK 】 or input 4, then input group number (1-6), then input phone
number like 13812345678 press key【OK】 to save. User can set 6 groups alarm
phone numbers at most. Then press key 【BACK】to return to desk page.
Delete SMS Phone No.
As shown in picture 3-1, after entering to the settings of SMS Phone No., press key
【Menu】 to delete Help Phone No. and press key【OK】 to save, then press key
【BACK】to return to desk page.
3.6.5 Phone Call
As shown in picture 3-1, press key【UP/DOWN】to select 【5. Phone Call】and
press key【OK】, then input phone number like 10086. Press key【OK】 to start
calling. Press key 【BACK】to hang up.
ESC. Return
Add Remote Control
Enter Number(00-99):
Total:001
Total:000
OK.Enter
Smart Accessories
Enter Number:
0.Siren
9.Alarm Out
Smart Accessories
0.Siren
9.Alarm Out
Arming Key.ON
Disarm Key.OFF
OK.Enter
ESC. Return
Enter Number:0
Arming Key.ON
OK.Enter
OK.Enter
ESC. Return
Smart Accessories
Enter Number:0
OK.Enter
0.Siren
9.Alarm Out
Arming Key.ON
Disarm Key.OFF
ESC. Return
Add Detector
Enter Number(00-99):
Disarm Key.OFF
ESC. Return
OK.Enter
ESC. Return
Picture 3-2
3.7.1 Add Remote Control
As shown in picture 3-2, press key【1. Add Remote Control】. With the voice
prompt “Please input numbers (01-99)” ( e.g. Study No. 1 remote control, then
input 01, study No. 22 remote control, input 22), then press key【OK】. At this
moment, press any key on remote controller to send a signal to host. Host voice
prompts “Add Successfully ” with 【Add Successfully】on display, which means
the remote control has been programmed to the host. If voice prompts add
repeatedly, it means that the remote control has been added to the host already
and couldn’t be programmed repeatedly. To learn more remote controls, press
any key on other remote controls. The host can study as most as 150 different
remote controls.
3.7.2 Delete Remote Control
As shown in picture 3-2, press key【3. Delete Remote Control】. With the voice
prompt “Please input numbers (01-99)”( e.g. delete No. 1 remote control, then
input 01; delete No. 22 remote control, input 22; delete all by pressing key 【
ARM】),then press key【OK】.
3.7.3 Add Detectors
As shown in picture 3-2, press key【2. Add Detectors】. With the voice prompt “
Please input zone numbers (01-99)”( e.g. Study Zone No. 1 remote control, then
input 01, study Zone No. 22 remote control, input 22), then press key【OK】. At
this moment, trigger detectors to send a signal to host. Host voice prompts “Add
Successfully ” with 【Add Successfully】on display, which means detector has
been programmed to the host. If voice prompts add repeatedly, it means detector
has been added to the host already and couldn’t be programmed repeatedly.
To learn more detectors, trigger other detectors. The host can study as most as
150 different detectors.
3.7.4 Delete Detectors
As shown in picture 3-2, press key【4. Delete Detectors】. With the voice prompt “
Please input numbers (01-99)”( e.g. delete Zone No. 1 remote control, then input
01; delete Zone No. 22 remote control, input 22; delete all by pressing key 【ARM
】), then press key【OK】.
3.7.5 Intelligent Accessories
As shown in picture 3-2, press key【1. Add Remote Controls】. With the voice
prompt “Please input numbers:”( 0 means siren, 9 means alarm relay), then press
key【Arm】 and host sends open signals; press key【Disarm】and host sends
close signals.
3.7.5.2 Code Match between Host and Smart Socket
Code Match Method: In smart socket standby mode, long press key SET for 5s
until the socket indicator light turns out to enter learning state; Then on intelligent
accessories page, press key 【ARM】or【DISARM】 to switch smart socket ON or
OFF, host will send signal ; smart socket indicator light flashes twice, which means
the code match successfully, then press the SET key of smart socket to exit the
learning state.
Check the Success of Code Match: after smart socket exit learning state, press
key【ARM】or【DISARM】 to switch smart socket ON or OFF, if it’s OFF, smart socket
lit RED; if it ’s ON, socket lit BLUE, which means the host match code successfully
with smart socket.
3.7.5.1 Code Match between Host & Wireless Strobe Siren
Code Match Method: In strobe siren standby mode, long press key SET until the
alarm indicator lit constantly to enter learning state; Then on intelligent accessories
page, input No. 0, press key【ARM】or【DISARM】, host will send signal as shown
in picture 3-2; wireless strobe siren will beep twice and indicator flashes twice
after receiving the signal, which means the code match successfully, then press
the SET key of strobe siren to exit the learning state.
Check the Success of Code Match: after wireless strobe siren exit learning state,
press key【ARM】or【DISARM】 to switch【Wireless Strobe Siren】ON or OFF, if it ’s
OFF, strobe siren will beep “di di”; if it ’s ON, siren will alarm siren, which means
the host match code successfully with wireless strobe siren.
Mart Socket S71
3.8 System Set
On main page, press key【UP/DOWN】to move the cursor behind【System Set】,
then press key【OK】or number 3 to enter system set page, as shown in picture 3-3.
3.8.1 Delay Set
On system set page, put cursor on 【Delay Set】, and press key【OK】or number
1 to enter delay set page, as shown in picture 3-3.
Siren J009
Solar Strobe Siren J1
3.8.1.1 Delay Arm Set
On delay set page, put cursor on【Delay Arm Time】, input the delay time(00-99s),
00 means without delay, arming immediately, then press key【OK】to save setting,
as shown in picture 3-4.
3.8.1.2 Delay Alarm Set
On delay set page, press key【DOWN】to move cursor behind【Delay Alarm Time】,
input the delay period(00-99s), 00 means without delay, alarming immediately,
then press key【OK】to save the setting.
System Settings
1.Delay Settings
2.Password Settings
3.Voice Settings
4.Siren Settings
5.Phone&SMS Settings
OK.Enter
ESC. Return
Picture 3-3
Delay Settings
Arming delay:00
Alarm delay:00
OK.Enter
ESC. Return
Picture 3-4
Password Settings
Password:1234
Keypad Lock:OFF
OK.Enter
ESC. Return
Picture 3-5
3.8.2 Password Set
On system setting page, press key【UP/DOWN】to move the cursor behind【
Password Set】, then press key【OK】or number 2 to enter password set page, as
shown in picture 3-4.
3.8.2.1 System Password
On password setting page, input four digits new passwords in System Password (
original password is 1234), press key 【OK】to save.
3.8.2.2 Keypad Password
On password setting page, press key【DOWN】to move the cursor behind【Keypad
Password Set】, press key【MENU】 to switch it ON or OFF and press key【OK】to
save setting. If the lock function of keypad is open, host will lock when it enters
into dormancy or alarm state. Unlock the keypad by inputing the password. The
factor y default is unlock.
3.8.3 Voice Setting
On system setting page, press key 【UP/DOWN】to move the cursor behind【Voice
Setting】, then press key【OK】or number 3 to enter Voice Setting page, as shown
in picture 3-6.
3.8.3.1 System Volume
On voice setting page, put the cursor on【System Volume】, input volume level
0-7, then press key【OK】to save the setting. 0 means mute during the operation
to host, and 7 means the largest volume, as shown in picture 3-7. The factor y
default is level 5.
System Settings
1.Delay Settings
2.Password Settings
3.Voice Settings
4.Siren Settings
5.Phone&SMS Settings
OK.Enter
ESC. Return
Picture 3-6
Voice Settings
System volume:5
System voice:ON
3.8.3.2 System Voice
On voice setting page, press key【DOWN】to move the cursor behind【System
Voice】, press key【MENU】 to switch it ON or OFF and press key 【OK】to save
setting. If switch it off, there is no voice prompt only button voice during operation.
The factor y default is on.
Siren Settings
Built-in volume:05
Siren on time:01
3.8.4 Siren Setting
On system setting page, press key 【UP/DOWN】to move the cursor behind【Siren
Setting】, then press key【OK】or number 4 to enter Siren Setting page, as shown
in picture 3-8.
3.8.4.1 Internal Siren Volume
On siren setting page, input volume level 0-7, then press key 【OK】to save the
setting. 0 means mute, and 7 means the largest volume, as shown in picture 3-8.
The factor y default is level 5.
3.8.4.2 Siren Alarm Time
On siren setting page, press key 【DOWN】to move the cursor behind【Siren Alarm
Time】. The siren alarm time is between 0-20 minutes, then press key【OK】 to
save setting. 0 means mute, the factor y default is 1 minute.
3.8.5 Phone Message Setting
On system setting page, press key 【UP/DOWN】to move the cursor behind【Phone
Message Setting】, then press key【OK】or number 5 to enter phone message
setting page, as shown in picture 3-8.
3.8.5.1 Message Reply
On phone message setting page, press key【MENU】 to switch it ON or OFF and
press key【OK】to save setting. If switch on, the host will send message to advise
wheather settings are correct when users do settings by message. The factor y
default is on.
3.8.5.2 Alarm Output
On phone message setting page, press key 【DOWN】to move the cursor behind
【Alarm Output】, press key【MENU】 to switch it ON or OFF and press key【OK】
to save setting. If switch on, relay will shortcut output while the host alarming,
COM and NO shortcut. The factor y default is on.
Phone&SMS Settings
OK.Enter
ESC. Return
Picture 3-7
OK.Enter
ESC. Return
SMS reply:ON
Alarm out:ON
Sound Settings
Enter Number(00-99):01
Sound Settings
Siren Sound:ON
Picture 3-8
OK.Enter
ESC. Return
Picture 3-9
1.Delay Settings
2.Password Settings
OK.Enter
ESC. Return
Picture 3-10
OK.Enter
ESC. Return
Picture 3-11
3.8.6 Alarm Output
Test Time】, input self test time, press key【OK】to save setting.
On system setting page, press key 【UP/DOWN】to move the cursor behind【
Remote Control Voice Setting】, then press key【OK】or number 6 to enter setting
page, as shown in picture 3-10. With the voice prompt “Please input numbers:”(
No:01-99), then press key【OK】to enter next page; press key【MENU】 to switch
it ON or OFF and press key【OK】to save setting, as shown in picture 3-11. If switch
it on, it means the remote control will sound “didi” when using this numbered
remote control to arm and disarm. The factor y default is on.
3.8.7 Scheduled Arm/Disarm
On system setting page, press key【UP/DOWN】to move cursor behind【Scheduled
Arm/Disarm】, then press key【OK】or number 7 to enter setting page, as shown
in picture 3-12. With the voice prompt “Please input numbers:”, enter No between
1-4; then press key【OK】to enter next page;with voice prompt input scheduled
arm time, scheduled disarm time. Move cursor behind scheduled switch, press
key【MENU】to switch it ON or OFF and press key【OK】to save setting, as shown
in picture 3-11. If switch it on, the host will automatically arm and disarm in
preset time.
Timing Settings
Enter Number(1-4):
OK.Enter
ESC. Return
Timing Settings
Arming time:
:
Disarm time:
:
CID Settings
User code:0000
Arm&Disarm:No send
Week:
Test time:
Timing:ON
Test week:
OK.Enter
Picture 3-12
ESC. Return
Picture 3-13
OK.Enter
:
ESC. Return
Picture 3-14
3.8.8 Scheduled Arm/Disarm
On system setting page, press key【UP/DOWN】to move cursor behind【Network
Center Setting】, then press key【OK】or number 8 to enter setting page, as shown
in picture 3-14.
3.8.8.1 User Area Code
On network center setting page, input four CID code in【User Area Code】, press
key【OK】to save setting. The factor y default is 0000.
3.8.8.4 Self Test Week
On network center setting page, press key【DOWN】to move cursor behind【Self
Test Week】, input any week no. 1234567, press key【OK】to save setting.
3.8.9 Low Batter y and Anti-tamper Setting
On system setting page, press key【UP/DOWN】to move cursor behind【Low
Batter y and Anti-tamper Setting】, press key【OK】or number 9 to enter setting
page, as shown in picture 3-15..
3.8.9.1 Back Light Power Saving
On low batter y and anti-tamper setting page, on the item【Back Light Power
Saving】, press key【MENU】to switch on or off and press key【OK】to save
setting. If switch it on, TFT color display will close to save power. The factor y
default is open.
3.8.9.2 Anti-tamper Switch
On low battery and anti-tamper setting page, press key【DOWN】to move cursor
behind【Anti-tamper Switch】, press key【MENU】to switch on or off and press
key【OK】to save setting. If switch it off, the host will not alarm if anti-tamper
switch is triggered. The factor y default is open.
3.8.9.3 Illegal Arm
On low battery and anti-tamper setting page, press key【DOWN】to move cursor
behind【Illegal Arm】, press key【MENU】to switch on or off and press key【OK】
to save setting. If switch it on, the host cannot arm if it fails to receive the signal
sent by sensor closure. The factor y default is close.
LCD Saved&Tamper
1.Part recover y
2.Full recover y
3.8.8.3 Self Test Time
On network center setting page, press key【DOWN】to move cursor behind【Self
Full recover y
Please hold <OK> key 10
seconds!
Illegal Arming:OFF
AC Failure:0
OK.Enter
ESC. Return
Picture 3-15
3.8.8.2 Arm/Disarm Upload
On network center setting page, press key【DOWN】to move cursor behind【Arm
/Disarm Upload】, press key【MENU】to switch 【Not Upload】/【Arm Upload】
/【Disarm Upload】/【Arm/Disarm Upload】, press key【OK】to save setting. The
factor y default is【Not Upload】.
Restore Factor y
LCD Save: ON
Tamper : ON
OK.Enter
ESC. Return
Picture 3-16
OK.Enter
ESC. Return
Picture 3-17
3.8.9.4 Power Off Setting
On low battery and anti-tamper setting page, press key【DOWN】to move cursor
behind【Power Off Setting】, input 0-5, press key【OK】to save setting. 0 means
close prompt function, 1 means AC off, 2 means dialing, 3 means dialing+siren,
4 means dialing+linkage, 5 means dialing+siren+linkage, The factor y default
is 0.
3.8.10 Restore Factor y Setting
In the system setting page, press【up/down】key to move cursor to the【Restore
Factor y Settings】. Then,press【OK】button or press key【0】directly to enter into
the Restore Factor y Setting page , as shown in Figure 3-16.
type setting, dialing group when alarming and wired zones open/closed alarms,
etc as shown in Figure 3-23. The setting is as follows:
Zone Settings
Zone Settings
Enter Number(00-99):01
3.8.10.1 Partial Restoration
After entering into Restore Factor y Setting page, press 【OK】button, the host will
remind whether to restore factor y settings. After restoring factor y setting, the
remote controls and detectors added before would not be deleted, but all the
other parameters will be restored to the factor y state.
3.8.10.2 Full Restoration
After entering into Restore Factor y Setting page, press【2】key and then long
press【OK】key until a host reboot is completed. In this situation, all the remote
controls and detectors will be deleted and all the parameters will be restored to
factor y state, as shown in Figure 3-17.
ESC. Return
Picture 3-21
OK.Enter
ESC. Return
Picture 3-22
OK.Enter
ESC. Return
Picture 3-23
3.10.1 Network Even Code
After entering next level menu, input event code in the Networking Event Code.
100 means medical aid, 110 represents fire, 121 denotes robber y, 122 denotes
a noiselessly rob, 130 represents burglar y, 131 denotes the perimeter burglar y,
151 denotes gas leakage. Press【OK】to save.
3.10.2 Internal Siren On/off
3.9 Recording Setting
Host will play the preset recording after dialing the preset alarm number . And the
recording setting method is as below:
Message Record
OK.Enter
Zone Settings
CID Event code:130
Siren:ON
Types:NORMAL
Zone dial:123456
Message Record
Press 1 to start recording
Message Record
After entering the next menu, press 【Down】 key to move the cursor to 【Alarm
alerting】 .Press 【Menu】 key to switch ON and OFF and then press 【OK】 to
save. If you select Off, it indicates that host will not alert when the detectors in
that Zone receives alarms.
Recording……09
3.10.3 Set Zone Type
OK.Enter
ESC. Return
Picture 3-18
OK.Enter
ESC. Return
Picture 3-19
OK.Enter
ESC. Return
Picture 3-20
On main menu. as shown in picture 3-18, press【UP/DOWN】key to move the
cursor at【Recording】, then press key【OK】or number 4 directly to enter recording
setting page, as shown in picture 3-19; On recording setting page, press key【
BACK】to return to the main menu; Press any key to start recording. The recording
time is 10s, as shown in picture 3-20. The recording should be brief, e.g. “ This is
XXX’s house, it ’s intruded illegally, please help”.
Host will exit automatically after 10s, and user can press any key to end recording
during recording process.
3.10 Zone Management
On the main menu page, as shown in Figure 3-21, press [Up / Down] key to move
the cursor to the zone management. Press [OK] button or press number 5 directly
to enter zone management page, as should in Figure 3-22 . Then input the zone
number (1-99) and press [OK] to enter the next level menu. Zone attribute setting
mainly includes networking feature code setting, built-in siren on/off setting , zone
After entering the next level menu, press【DOWN】 key to move cursor to 【Zone
Type】. Press 【Menu】 key or press numbers directly to select: 【1】Normal,【2】
Stay,【3】Intelligent,【4】Emergency,【5】Close,【6】doorbell,【7】Welcome,
【8】Help the Senior, then press key[ OK] to save.
3.10.4 Set Sub Zone Dialing
After entering the next menu, press 【Down】 key to move the cursor to 【Zone
Dialing】. Input user number when this Zone alarms. It can be any desired phone
groups among 123456, but if the zone type is for 【Help the Senior】, the group
is fixed to help number and can’t be set, then press 【OK】 to save.
3.11 Clock Management
On the main page, press 【Up / Down】 key to move the cursor to 【clock
management】, then press the 【OK】button or press number 6 to enter clock
management page. Press 【Menu】button to switch the display format of the
date, and press 【Up / Down】 key to switch among year, month, date, hour,
minute and second; Press numeric key to input the numbers then press 【OK】
to save, as shown in Figure 3-24.
Clock Settings
yy-MM-dd
15-07-24 09:16:52
Histor y List
1.Alarm list
2.Arm&Disarm list
Alarm date: Alarm time: :
Alarm
OK.Enter
ESC. Return
Picture 3-24
OK.Enter
ESC. Return
Picture 3-25
Chapter Four: SMS Setting and Command Chart
Alarm list
001 Histor y
OK.Enter
ESC. Return
Picture 3-26
In addition to set parameter through host menu, SMS or Fetion Message can also
set host parameters. The form is as below:【System Password】+【Command
Number】+ parameter 1+parameter 2+parameter 3+parameter 4. All commands
begins with system password, and 1234 is system’s initial password. Users can
change system password and since then, users should use the modified password,
or host will not response to the commands.
3.12 Check Records
On the main page, press【Up / Down】key to move the cursor after to【Check
Records】, then press【OK】button or number 7 into checking records page, as
shown in Figure 3-25.
3.12.1 Alarm Records
On【Check Records】page, press【OK】key to enter【Alarm Records】, as shown
in picture 3-26. Press key【UP/DOWN】to check alarm records. At most 102 records
can be saved, and each record includes information like record number, alarm
date, time, zones etc.
3.12.2 Arm/Disarm Records
On【Check Records】page, press【UP/DOWN】key to move the cursor to【Arm/
Disarm Records】and press【OK】or number 2 to enter【Arm/Disarm Records】
page, as shown in picture 3-27. Pres【UP/DOWN】to check Arm/Disarm records.
As most 72 records can be saved, and each record includes information like
record number, Arm/Disarm date, time and mode, etc.
Arm&Disarm list
System Version
NO. Name
CommParameter1
and No.
Para. 2
Para. 3
Para. 4
Example
1
Disarm
0
#
12340#
Disarm
2
Arm
1
#
12341#
Arm
3
STAY
2
#
12342#
STAY
4
Ganged
Socket
ON
3
#
12344#
Ganged Socket ON
5
Ganged
Socket
OFF
4
#
12345#
Ganged Socket OFF
6
Check
host
general
parameters
11
#
123411#
Check host voice
volume, Siren’s state,
etc
#
12343113899998888#
Set first group phone
number
Set phone
7 No.
3
1~9
Group 1-6 is
common
number; 7-9
is the senior
help number
3
1~9
#
123435#
Delete 5th Phone No.
01~09
1~9group
#
12343008#
Check 8th Phone
Number
#
12344113899998888#
Set first group phone
number
System Version
001 Histor y
13899998888
(User can set
30 as the
number)
Date: Time: :
Version:E150206K6
IMEI:866779922002277
Status:
OK.Enter
ESC. Return
Picture 3-27
OK.Enter
ESC. Return
Picture 3-28
OK.Enter
ESC. Return
Delete
8 Phone No.
Check
9 phone No.
30
Picture 3-29
3.13 Check Product Version
On main menu page, as shown in Figure 3-28, press【UP/DOWN】to move the
cursor to【Check Product Version】and then press【OK】or number 8 directly to
enter to the version checking page. Users can see the model number of the
product, software version and GSM module IMEI code, as shown in Figure 3-29.
Set SMS
number and
10 central
number
Delete
11 Phone No.
Check
12 phone No.
Set system
13 password
4
1~8;
Group 1~6 is
SMS number;
7~8 is central
number
4
1~8
#
1234435#
Delete 5th Phone No.
40
01~08
1~8group
#
123443008#
Check 8th Phone
Number
50
Four any
figure among
0-9
#
1234509876#
Set user password
as 9876
13899998888
( User can set
30 as the
number)
Delay Arm
14 period
51
#
00~99
setting
Delay Alarm
15 Period
52
#
00~99
setting
Set Alarm
16 Siren Period
17 Date /Time
setting
Check
18 system time
Arm/Disarm
19 at fixed
time
53
56
57
57
fixed time
Set Zone
21 Attributes
Check Zone
22 Attributes
Set Network
Feature
23 Code
Set system
24 volume
Set Zone
Alarm SMS
25 Message
20150520
60
60
01-04;
01-04 group
fixed time
26
203000
01~99;
01-99 Zone
1234567
Week
1-Normal Zone
2-STAY Zone
3-Intelligent Zone
4-Emergency Zone
5-Close Zone
6-Doorbell Zone
7-Welcome Zone
8-Help The
Senior Zone
01~99;
01-99 Zone
79
1~7
80
01~99;
01-99 Zone
01~99;
01-99 Zone
100-Medical
treatment
110-Fire
121—Robber y
122-Silence Rob
130-Burglar
131-Surrounding
151-Gas
ABCEFG;
SMS Contents
(less than 25
characters)
1-Siren
on when
alarming
2-Siren
off when
alarming
12345230#
Set Delay Alarm Period
as 30s
12345305#
Set Alarm Siren Period
as 5 Minutes
#
123456201505202030
00#
Set time as 2015//20/
20:30:00
#
123456#
Check system time
#
#
01~99;
01-99 Zone
64
81
08001800
time
01-04;
01-04 group
fixed time
Content
Check Zone
Alarm SMS
Message
Content
#
56
Check Arm/
20 Disarm at
00~20
Minutes
12345130#
Set Delay Arm Period as
30s
#
12345701080018001
2345#
Set the first fixed time,
Arm automatically at
8:00 form Monday to
Friday,disarm at 18:00
12345701#
Check the first group of
time for Arm/Disarm
1234601880#
Set zone 18 as Help the
Senior Zone, Siren
doesn’t alert when
alarming.
#
12346001#
Check 01 Zone Attribute
#
12346438151#
Set Zone 38 as Gas zone
#
1234793#
Set Alarm Volume Level
as 3
#
12348060 Front door is
open#
Set Zone 60 Alarm
Message Content as “
Front door is open”
#
12348160#
Check Zone 60 Alarm
Message Content
Set LCD
powering
27 saving ON/
84
0-OFF
1-ON
#
1234840#
Set LCD always ON
87
1~7
#
1234873#
Set Built-in Siren volume
as 3
#
1234911#
Set Arm Upload
#
1234929988#
Set CID No. as 9988
#
12349401007#
Set self-test with the
center at 01:00 on ever y
Sunday.
#
12349898#
OFF
Set Built-in
28 Siren
volume
Set Arm/
Disarm
29 Upload
91
Center
Set Network
30 CID Number
92
0~9 any four
digital CID
Number
94
0800;
Time
Set Network
31 Self-test
0-No upload
1-Arm upload
2-Disarm
upload
3-Arm and
Disarm upload
time
1234567
Week
Restore
32 Factor y
9898
Reset
Notice:“1234” in above chart indicates system password. User should use the
new password is the user has change the password.
Chapter Five APP
The host can be controlled remotely by mobile APP. For iOS system, during
operation it will jump to the SMS interface. Android system mobile phone will not
jump to the SMS interface, but will complete texting in the backstage.
5.1 App Downloading
mobile phone users of iOS system should enter App Store, enter "G18" or sweep
the next two-dimensional bar code in Figure 5-1, then the user can search APP
of G18 alarm system. Download and install the APP.
Picture 5-1
Picture 5-2
Android mobile phone users can enter Baidu Mobile Phone Assistant software,
enter "G18", or sweep the following two-dimensional code in figure 5-2, you can
search G18 alarm system APP. Download and install the APP.
5.2 Add Host Account
This step can bind the control panels to APP. One G18 APP can add multiple control
panel. You can operate several control panels through one APP.
The method to add host account: Click G18 APP, enter【User Log in】interface.
Click button【 】 to enter user registration interface; Then enter the user name,
host number and account password, and click [Finish] button to complete the
registration. The host number entered is the SIM card number within the host.
Account name can be customized. Account password is system password.
+
Login
Login
+
Login
+
receives text message, the panel will make a sound like”di” and reply message
to the phone automatically. The setting is successful.
Take setting alarm phone number as example:
Click account name and enter the user interface. Then slide to the left to enter
into the setting interface. Click【Set Phone Number】and select【Alarm Phone
Number】to enter the alarm phone number setting page . The interface can set
6 groups of alarm telephone numbers (1-6 group), and three groups of the elderly
help calls (7-9 group). Click【Enter Alarm Number】or【 】 icon , input alarm
number at pop-up input field to set. Click 【OK】to send text messages to host
SIM card. Click【 】icon, you can quer y alarm telephone numbers; click【 】
icon to delete alarm phone numbers.
use
use
13712345678
1234
1234
Setting
CID
Alarm Phone No.
Number Set
1
input_telephone
1
input_telephone
Alarm Telephone Number
2
input_telephone
2
input_telephone
Alarm Code
3
input_telephone
3
input_telephone
Network Telephone Number
4
input_telephone
4
input_telephone
CID
5
input_telephone
5
input_telephone Confirm
Time Set
6
input_telephone
6
input_telephone
Defense Set
7
input_telephone
7
input_telephone
SMS Set
8
input_telephone
8
input_telephone
I II
9
input_telephone
9
input_telephone
I
5.3 Operation Method
Once register host account, it will display account name in the home Page. Click
account name to enter operation interface; Slide to the left to enter setting interface
and other interfaces. For, iOS system, click icon for sending information, APP will
jump to SMS message interface. Click【 Send】. When the SIM card of alarm host
Setting
Opera
Time Set
User:use
Defense Set
Host:13588888888
SMS Set
Password:1234
Switch
OFF
Change Host
Language
About
Opera
Set
Other
Opera
Set
Other
Opera
Set
Set
Other
Opera
Set
Other
Opera
Set
Other
Chapter Six Receiving Alarms and Remote Control
When there is an alarm, the host will automatically dial the telephone number
set before and alerting according to the setting. If the phone line of the owner
is busy or can not be connected, the system will dial the next pre-set number
automatically. The system will dial the preset phone number three times. After
receiving the alarm call, it will play the preset recording . The user doesn’t need
to enter a password. The following is the corresponding operation when pressing
the figures on phone:
Illegal Arm
ON
Opera
Alarm Phone No.
6.1 Handing method after receiving alarm:
Other
Current User
N umber Set
Alarm Phone No.
Other
Key [1]: Arming
Key[2]: Disarming
Key [3]: Monitoring On
Key[4]: Monitoring Off Key [5]: Speaker On
Key[6]: Speaker Off
Key [7]: Siren On
Key[8]: Siren Off
Key [9]: Ganged Socket On
Key[10]: Ganged Socket Off
Key [*]: Exit and hang up. The system would not dial next phone number.
Note: both monitoring and speaking time are 20 seconds. Press【3】key to continue
monitoring. Press【5】to continue speaking within 20s.
6.2 Remote control operation method
User can use any phone to call the phone number of the phone card on the host.
After a ringing cycle the host will automatically get through. After hearing prompt ,
enter password(host factor y default is "1234", there would be a prompt when
imputing the wrong password. The system will automatically hang up if the third
time is still incorrect). You will hear a prompt when password is correct. Then, press
following keys to control the corresponding functions:
Key [1]: Arming
Key[2]: Disarming
Key [3]: Monitoring On
Key[4]: Monitoring Off
Key [5]: Speaker On
Key[6]: Speaker Off
Key [7]: Siren On
Key[8]: Siren Off
Key [9]: Ganged Socket On
Key[10]: Ganged Socket Off
Key [*]: Exit and hang up. The system would not dial next phone number.
Note: both monitoring and speaking time are 20 seconds. Press【3】key to continue
monitoring. Press【5】to continue speaking within 20s.
7.3 System factor y default
System Password
1234
SMS Message
ON
Remote control
ON
Remote Alarm
ON
Alerting time
1 Minute
Delay Alarm
0 Seconds
Delay Arm
0 Seconds
1-99 Zone Alarm
Alarm Alerting
1-99 Zone Alarm Message
XX Zone Alarm
Chapter Eight Install Detectors
8.1 Installation and Usage of Door Sensor
Door sensor is used for sensing the closing and opening state of the door, and
is consisted of transmitter and magnet two parts. It can be installed on doors,
windows or any object that can be closed and opened. When transmitter is
separated from the magnet, door senser will send alarm signal to alarm panel,
host will alarm.
Chapter Seven Technical Parameters
7.1 Technical Parameters
Input Voltage: USB5V
Standby Current:<60mA
Alarm Current:<300mA
Wireless Frequency:433MHz
GSM Standard:Support GSM850/900/1800/1900MHz
Backup Batter y: 3.7V 800mA Lithium Batter y
Standby hours: 8h
Alarm Loudness:80dB
Wireless distance: 100 meters(in open area)
7.2 Factor y default zone type
Normal Zone STAY Zone
Intelligent
Zone
01-59 Zone 60-79 Zone 80-89 Zone
Help the
Senior Zone
Doorbell
Zone
Welcome
Zone
Emergency
Zone
90 Zone
91 Zone
92 Zone
93-99 Zone
The door contact should be installed on the movable door or windows. Firstly,
make the installation position clean. Take out wireless door sensor, then stick the
double faced adhesive tape on the bottom. The installation should note the
following items:
1.The door sensor part A (transmitter) and part B (magnet) should be installed
separately, that is, A on fixed door and B on movable door.
2. A and B should be in the same vertical line and the distance between A and
B should not be greater than 1 cm.
3. After the installation, the indicator light flashes for 1s as the door open, that
means the door sensor is installed successfully.
4.The indicator lighting for 1 second means alarm. The indicator in constant light
is a suggestion of low power.
5.A, B can also be reinforced by screws, (A: remove the bottom cover, strengthen
the screw and then cover the bottom agian; B can be directly fixed by the screw.)
8.2 Installation and Use of PIR Motion Detector
Before use, make sure the power switch of PIR motion sensors is ON. Installation
height is about 2.2 meters above ground and it should be installed in the corner
of the room to get the best detection range. At the same time, it should form a
certain angle with the walking line ( 90 degree angle is best for detection).
Installation:
Talk out the supplied bracket, insert the bracket to the slot. Take out the pedestal
and fix it with two screws on the wall. Press the PIR with bracket into the center
hole of the pedestal. And then adjust the best angle of detector. (This method is
suitable for project installation)
Attention:
1.The detector should not face the outside of window directly.
2. There should be no any big objects for obstruction within coverage of detection, .
3. There should be no two infrared detectors in the same space as they will possibly
intervene with each other.
4.Avoid facing window, cooling or warming machine, stoves, or other appliances
that cause temperature changing sharply, which may cause false alarm.
5. Infrared detector should be used indoor only.
Chapter Nine Troubleshooting
Troubleshooting
Reasons
1.No dialing for alarm
1.Not arming
2.alarm phone unset
3.parts improperly installed,
distance too far
4.code not match
1. do arming operation
2.re-set according to the
instruction book
3. adjust the location of parts
4. re-coding
2. Can’t remote
operate
1.input wrong password
1. Correct password or change
to a new password
3. Host can’t read
SIM card or don’t
dial and text to
preset alarm
phone number
1.No SIM card
2.PIN code is set for SIM card
3.bad GSM signal
4.SIM card has scratched
copper
5.Alarm phone number unset
6.Message Alarm number
unset
7.Card balance is insuffic
ient or out of date
8.Message function is OFF
1、Insert SIM card
2、Cancel PIN code
3、change to a strong signal place
4、change to a normal SIM card
5、set alarm phone number
6、set message alarm number
7、charge SIM card
8、activate the message function
4. remote controller
not work
1.coding unmatched with
the host
2.insufficient power
3.batter y pieces poor
contact or corroded
4.unmatched with host
1. re-coding
2. change batter y of the same type
3. eliminating the dirt on the
pieces caused by corrosion
4. contact the local dealer to
change the matched remote
controller
5. remote controller
not work
1.coding unmatched with
the host
2.insufficient power
3.batter y pieces poor
contact or corroded
4.unmatched with host
6. PIR sensor not work
1.coding unmatched with
the host
2.insufficient power
3.batter y pieces poor
contact or corroded
4.unmatched with host
7. The transmitter
distance for host is
shortened
1.a nearby emitter is sending
signal
2.The host receiver stops work
3.Power supply of standby
batter y of the host is
insufficient
Methods
1. re-coding
2. change batter y of the same type
3. eliminating the dirt on the pieces
caused by corrosion
4. contact the local dealer to
change the matched remote
controller
1. re-coding
2. change batter y of the same type
3. eliminating the dirt on the pieces
caused by corrosion
4. contact the local dealer to
change the matched remote
controller
1.find the interfering source and
eliminate it
2.send the host back to the factor y
for repairing
3.check whether the power supply
is plugged well