Datasheet - Intelligent Life Safety Systems Limited

SECTION 6: page 1
Section 6:
by Honeywell
Vigilon System Overview
& Control Panels
Contents
Vigilon System
•Overview
•Architecture
•Key Benefits
Control Panels
•Panel Overview
•Vigilon
•Vigilon Compact
•Repeat Panels
•Vigilon Repeat
•LCD Repeat Indicator
•A3 Mimic
SECTION 6: page 3
6 : vig i lon fir e d etection
by Honeywell
Vigilon System Overview
The feature-packed Vigilon analogue addressable fire detection and alarm system from Gent offers medium to large sized building
owners the latest in system flexibility and control panel aesthetics.
Vigilon offers a degree of system sophistication that has not previously been available and incorporates a host of features designed to
make it the simplest system to install, configure and use.
As well as providing the user with clear comprehensive information in the event of a fire, Vigilon additionally provides an entire historic
log of the system’s management information. Should a system fault occur a detailed explanation is shown and the user can at any time
navigate through the faults history.
MCP
Repeat
Panel
S-Quad Sensor
Sounder
T-breaker
MCP
Max Loop
Length 1000m
Alarm
Sounder
Sprinkler
Interface
Units
Door Release or
Plant Shutdown
S-Quad Sensor
Sounder
Beam
Transmitter
Beam
Receiver
S-Quad Sounder Strobe
WINMAG
Loop 1
Manned
Centre Link to
Fire Station
Loop 2
Loop 3
Loop 4
Secure
Fibre
Network
Secure
Copper
Network
Node
Node
Node
Secure
Fibre Optic
Loop 2
Loop 3
Domain
Loop 4
(Max 200 panels/
nodes per system)
ACU
S-Quad
Sensor
4 or 6 loop,
24 or 72 hour
standby
Loop 1
DAU
Up to 200 Devices
per Loop
A3 Mimic Panel
MCP
Loop 1
Loop 6
MCP
S-Quad Sensor/
Speech Strobe
SECTION 6: page 4
6 : vig ilon fire detection
by Honeywell
10 reasons to specify Vigilon
1
The Power of Vigilon Supports the largest number of fire detection and
alarm products on the same 2 cables with soft or SAFE (Soft Addressed
Firmware Encoded) addressing options.
Minimise False Alarms The combined power of S-Quad and the Vigilon
panel provides quick, intelligible decision making. The S-Quad dual angle
optical sensor recognises a clear distinction between smoke and steam.
3
Rapid Fire Detection
The 4 separate sensing elements in the
S-Quad, including CO, can be set with individual sensitivity levels and
sensor ‘states’ can be programmed for different time periods to suit all
applications and environments.
Cost Savings Cable runs are shorter. 2 core costs less than 4 core.
Overall cable costs are normally 30% less than other systems.
5
Create Seamless Network Connect up to 200 panels together and
retain control on large or complex sites. Also, new buildings or extensions
are easily accommodated onto the existing system.
Customise your Fire Plans
Evacuating public areas or production
lines is disruptive and costly. Vigilon Compact’s powerful software gives
you flexibility. Areas throughout the building can be sectored to give
an evacuate or alert signal on alarm, or can be configured with pre-set
delays.
7
Safe Evacuation
Voice messaging capability through the sounder
functionality of S-Quad ensures quick and safe evacuation in the event
of a fire.
Loop powered sounder/strobe Loop powered sounder/strobes save
on cabling and interface costs whilst ensuring compliance with the
Disability Discrimination Act 1995. Built-in high intensity flashing strobes
warn those with hearing difficulties of a potential fire hazard – now a
legal requirement in all public buildings.
9
Clear Information An 8-line by 40 character display means the user is
not limited in describing the position or nature of an emergency. A clear
backlit LCD display reduces confusion and speeds response.
Integrated Voice and Graphics Systems Vigilon may be integrated
with Gent’s Vigilon Voice evacuation system, or connected to Supervisor,
a graphic display for single point control and monitoring.
SECTION 6: page 5
Section 6.1:
Vigilon Control Panels
by Honeywell
SECTION 6: page 7
6 . 1 : V i g i l on cont r o l Pane l s
Vigilon Panels Overview
by Honeywell
The Vigilon system offers a complete range of control panels that can be installed as standalone panels from 1 to 6 loops or as part of multi-panel
networks. A system that can meet the needs of a building today and in the future.
The Vigilon System is suitable for all building types and sizes
l
Vigilon’s modular concept makes systems simple to design for any building. Panels can be installed as standalone units or as multi panel
networks of 200 panels/nodes
l
Vigilon Compact is ideal for smaller systems needing upto 2 loops, while Vigilon panels can manage up to 6 loops allowing easy and
flexible panel selection
l
Vigilon panels are available with 24 and 72 hour standby power supply options
l
Both Compact and Vigilon panels can be installed in the same network
The Vigilon System responds quickly to real fires without the risk of false alarms
l
Vigilon’s advanced sensing technology and powerful software processing in the control panel quickly identifies real fires
l
Powerful software algorithms are used to match the pattern of activity in the sensor with data from test fires stored in the panel memory.
False inputs that do not match a real fire pattern are ignored or flagged as faults
l
The latest Vigilon range of S-Quad multi-sensors incorporates four separate technologies in the same sensor that combine to create a
range of sensing states appropriate for different environments
l
Unique programming options allow these different sensitivity states to be used to reduce the likelihood of known risks triggering a fire,
thus avoiding unnecessary evacuation while maintaining the ability to give a fast response to a real event
The Vigilon System is cost effective to install
l
The Vigilon loop manages the largest number and variety of devices, with up to 200 sensors, sounders and interfaces connected to the
same 2 core loop circuit
l
Vigilon sounders, strobes and interfaces are loop powered so there is no need for auxiliary power supplies
l
Every loop device includes an integral short circuit isolator reducing installation costs at the same time increasing system integrity
l
Multi-function devices combining sensor, sounder, speech and strobe reduce the number of individual devices that need to be installed
l
Every S-Quad sensor has a configurable, monitored input. This can be used instead of an interface saving on installation and product costs
The Vigilon System – flexible and simple to use
l
The Vigilon control panels have a simple user interface with LCD screen providing accurate information in an emergency
l
Every Vigilon loop device has a unique address assigned in software. Text labels, of up to 64 characters, can be assigned to each address.
This allows fires to be located quickly and assists troubleshooting in commissioning and maintenance
l
PC Based commissioning tools release powerful programming options that allow complex fire plans to be configured without extra
equipment
l
Flexible programming options are available at the panel so minor changes can be made without the need for PC tools
l
Multi-panel networks can be programmed seamlessly as one system. This allows for flexible design and system management
l
Vigilon Systems can be easily extended or changed. Additional loops and extra panels can be added without affecting the operation of the
existing installation
The Vigilon System provides peace of mind
l
The Vigilon panel, S-Quad sensors and S-Cubed sounders are certified by LPCB to EN 54 the European standard for fire detection systems
l
Loop architecture combined with short circuit isolators in every device ensures maximum tolerance to cable faults
l
S-Quad sensors can be locked into their base protecting them from unauthorised removal
l
Advanced loop and network communications protocols ensure a rapid response to fire triggers achieving response in under 3 seconds even
across networks
l
Gent by Honeywell’s Managed Protocol approach ensures that every system is designed, installed, commissioned and serviced by highly
trained Gent approved System Integrators
SECTION 6: page 8
6 . 1 : V i g i l on cont r o l Pane l s
by Honeywell
Vigilon 1 to 6 loop
Vigilon 1-6 loop control panels
can accommodate up to 200
devices on each loop.
The panel is available with 24 or
72 hour standby facility.
Advanced networking options
allow multi-domain networks of
up to 250 panels.
Vigilon’s backlit 8-line by 40
character display presents clear
indication of fire or fault locations.
To meet the requirements of
BS 5839 Part 1: 2002 the
panel also has separate zonal
Vigilon Control Panel
indication. This comprises 32
fire LED’s which give an overview
Technical Specification
indication ‘at a glance’ without
Type
Control panel
Control panel
Max No of Loops
4
6
Loop Capacity
200
200
Batteries
2 x 12V @12Ah
4 or 8 x 12V @ 21Ah*
Battery Standby
24 hours standby + 30 minutes
alarm upgradeable to 72 hours
standby + 30 minutes alarm
72 hours standby + 30 minutes
alarm
to 4 loops and a network card.
Approx Weight
16.5 Kg
16.5 Kg
The enhanced panel can offer 6
Operating Temperature
0°C to 45°C
0°C to 45°C
Relevant Standard
EN54 Parts 2 & 4
EN54 Parts 2 & 4
Cable Entry
Top and rear knockins
Top and rear knockins
Approvals
LPCB approval to EN 54
Parts 2 & 4 pending
LPCB approval to EN 54
Parts 2 & 4 pending
the need for manual intervention
by fire fighters.
The standard Vigilon Panel has
24 hour battery standby and up
loops and a network card and
up to 72 hour battery standby.
Fire
to
plans
can
precisely
be
tailored
meet
project
* 6 Loop Panel requires external battery enclosure
requirements.
Order Codes
A
B
C
Control Panel 406
543
172
Battery Box
309
112
382
Dimensions (mm)
EN54 Control Panels
Vigilon control panel
VIG1-24-NP
1-4 Loop Panel with 1 Loop Card
VIG1-24
1-6 Loop Panel with 1 Loop Card
VIG1-72
Additional loop
VIG-LPC
Network Card
Fibre Net
VIG-NC
B
1 Loop Card (no printer)
VIG-NC-FO
Stainless Steel Door for Vigilon
Main Control Panel
VIG-DOOR-SS
Vigilon Main control panel
flush mounting kit
VIG-FLUSH-SS
For existing systems to BS 5839 part 4
upgrades are available. Contact Gent for
details.
A
C
SECTION 6: page 9
6 . 1 : vi g i lon cont r ol Panels
by Honeywell
Vigilon Compact Control Panel
A one to two loop panel
accommodating
devices
per
up
loop
to
200
with
the
capability of networking with
other
Compact
or
Vigilon
Panels.
Multiple panel networks can
be
programmed
seamlessly
as one system, allowing for
flexible design and total system
management.
LCD
display
indication
Vigilon Compact Control Panel
of
allows
clear
fire
fault
or
location.
Site specific fire plans can
Technical Specification
Type
Control panel
be programmed to meet the
Max Number of Loops
2
evacuation
Loop Capacity
200
Networking Capacity
Upto 31 panels/nodes
building.
Ingress Protection
IP31
Approx Weight
16.6 Kg (with batteries)
Operating Temperature
0oC to +45oC
Relevant Standards
EN54 Parts 2 & 4
Batteries
2 x 12V @ 12 Ah
Battery Standby
24 Hours + 30 minutes alarm
Supply Voltage
216V – 253V 50Hz
Power Consumption
140 W
Cable Entry
Top and rear
Dimensions W x H x D (mm)
403 x 338 x 136
Auxiliary Contacts
Programmable to activate on Fire, Fault or Disablement.
(1 x SPCO 1 x DPCO)
Sounder Circuits
2 circuits @ 250mA each
Monitored input
1 input which is programmable to perform a logical
action via a command build
Communication ports
2 x RS485, 1 x RS232 selectable functions
Approvals
EN54 Parts 2 & 4
needs
of
the
Dimensions (mm)
Order Codes
Control Panel LCD Repeat panel
COMPACT-RPT
Flush fixing frame
COMPACT-FLUSH
Additional Loop card
403
COMPACT-24-N
COMPACT-LPC
Network card for Vigilon Network
Optical only sensor
COMPACT-NC
S4-715
Stainless Steel Options:
Stainless steel door
VIG-RPT-DOOR-SS
Stainless steel flush frame
338
136
COMPACT-FLUSH-SS
SECTION 6: page 10
6 . 1 : vigilon cont rol Panels
by Honeywell
Repeat Panel
A repeat panel repeats all
information provided to the
main control panel and provides
mains control functions.
The repeat panel is connected
directly to the loop but requires
a mains supply to run its battery
backed power supply.
Vigilon Repeat Panel
Technical Specification
Type
Repeat panel
Max No per Loop
4
Loop Capacity
N/A
Batteries
12V @ 7Ah
Battery Standby
24 hours standby + 30 minutes alarm, upgradeable to
72 hours standby + 30 minutes alarm
Approx Weight
9 Kg
Operating Temperature
0°C to 45°C
Relevant Standard
EN54 Part 2 & 4
Cable Entry
Top and rear knockins
Approvals
Applied for
Order Codes
Repeat Panel VIG-RPT-72*
403
Dimensions (mm)
Repeat panels
require a first fix
Stainless steel door VIG-RPT-1ST-FIX
VIG-RPT-DOOR-SS
Stainless steel flush frame COMPACT-FLUSH-SS
* VIG-RPT-72 is compatible with EN 54 and BS
Vigilon System
338
101
SECTION 6: page 11
6 . 1 : vig i lon cont r ol Pane ls
by Honeywell
LCD Repeat Indicator
The Vigilon Indicator Repeat
displays
Fire,
Fault
and
Disablement information on a
2 x 40 character LCD.
A
maximum
of
4
Repeat
Panels can be connected to
a Vigilon panel via an RS485
Communication Port.
LCD Repeat Indicator
Technical Specification
Type
LCD Repeat Panel (Indication Only)
Ingress Protection
IP30
Supply Voltage
21 – 30V dc
Power Consumption
Approx 30 mA
Approx Weight
0.75 Kg
Operating Temperature
0oC to +45oC
Communication ports
1x RS485 to communicate with the main control panel
Cable Entry
Top and rear knockins
Approvals
N/A
6
177
Dimensions (mm)
206
49
Wiring Details – LCD Repeat Indicator (indication only)
RS 485
Max Cable Length 1000M
One LCD repeat Indicator
can be powered from the
control panel, additional
repeat indicators must
be powered from an
additional power supply.
The communication link
to the panel is monitored,
so if power to the repeat
indicators fails the fault
will be reported at the
control panel.
24Vdc
Monitored
Battery
Backed
24V PSU
Vigilon Compact
Control Panel
Order Codes
LCD Repeat panel
COMPACT-RPT
SECTION 6: page 12
6 . 1 : vigilon cont rol Panels
by Honeywell
A3 Mimic Panel
TThe A3 mimic panel provides
a pictorial representation of a
building’s layout. This gives a
rapid, visual indication of the
location of any fire incident.
It can also be used to provide
indication of fault and supervisory
events in the system.
This one panel can be used as
a Zonal Mimic or can hold a
pictorial overlay to provide a
customised view.
The
A3
Customised
Mimic
panel can be mounted in either
landscape or portrait, while an
A3 Zonal Mimic panel must only
A3 Mimic Panel
Technical Specification
Type
A3 Mimic Panel
be mounted landscape when
Max Quantity per Loop
4
using the overlay supplied.
Batteries
2 x 6V @ 7Ah
Battery Standby
24 hours + 30 minutes alarm upgradeable to 72 hours
Approx Weight
7.9 Kg without batteries 10.5 Kg with batteries
Operating Temperature
0oC to 45oC
Cable Entry
Rear
Load Factor
3
Relevant Standard
EN 54 Part 2 & 4
Indicators
1536 Number – High Intesity Red LED’s
Approvals
Applied for
Order Codes
Mimics and Repeat Panels (EN54)
Vigilon Repeat Panel 72 hour (New) BS & EN
compatible VIG-RPT-72
Non-functional LCD Repeat Display (RS485
connection to panel)
COMPACT-RPT
A3 Zonal and Graphic Mimic
Dimensions (mm)
VIG-MIM-A3
Repeat Panel and Mimic
Accessories
Depth: 101
Vigilon Repeat Panel Battery Pack VSRPT-BATT
VSRPT-BATT-A3
Repeat Panel Flush Surround
VIG-RPT-FLUSH
338
Battery Pack for A3 Mimic (2 x 6v 7 Ah)
Stainless Steel Door for Vigilon Repeat
VIG-RPT-DOOR-SS
Stainless Steel Repeat Panel Flush Mounting
Kit
VIG-RPT-FLUSH-SS
403
LED Driver Board for Special Mimics
S4-34600
Open as PDF