QuickSpecs
HP Smart Array P212 Controller
Overview
The HP Smart Array P212 is HP's entry level PCI Express (PCIe) Serial Attached SCSI (SAS) RAID controller. The low profile, half
height card has 8 ports and utilizes DDR2-800 memory. The P212 is ideal for RAID 0, 1, 1+0, and can be upgraded with 256 MB
Cache module for RAID 5, 5+0 and additionally with Battery Kit and Smart Array Advanced Pack (SAAP) license key for RAID 6
(ADG), & 6+0.
Models
HP Smart Array P212
Controller
HP Smart Array P212/Zero Memory (ZM) Controller
HP Smart Array P212/256MB Controller
DA - 13203
Worldwide — Version 2 — February 13, 2009
462828-B21
462834-B21
Page 1
QuickSpecs
HP Smart Array P212 Controller
Overview
Upgrade Options
Optional Upgrades
256 MB Cache Module
Battery Kit (for Battery Backed Write Cache)
HP Smart Array Advanced Pack (SAAP)
NOTE: A license key, a minimum of 256MB cache, and battery kit is required to
enable features. For more information go to: http://www.hp.com/go/saap
DA - 13203
Worldwide — Version 2 — February 13, 2009
462968-B21
462969-B21
516471-B21
Page 2
QuickSpecs
HP Smart Array P212 Controller
Standard Features
The Smart Array
Advantage
Key Features
HP's innovative design and integration work of the Smart Array family of products creates customer value
that is unmatched in the industry. Use of Smart Array products across multiple applications results in a
much lower Total Cost of Ownership (TCO) than any other server storage RAID product. The HP Smart
Array family brings an unparalleled return on investment through:
Data Compatibility among all models of Smart Array controllers allows simple and easy upgrades any
time needs for higher performance, capacity, and availability increase. Even successive generations of
Smart Array controllers understand the data format of other Smart Array Controllers.
Consistent Configuration and Management Tools.
Tools All Smart Array products utilize a standard set of
management and utility software. These tools minimize Total Cost of Ownership (TCO) by reducing
training requirements and technical expertise necessary to install and maintain the HP server storage.
Universal Hard Drive form factor is for use across multiple HP servers, disk enclosures and storage
systems. With compatibility across many enterprise platforms, you are free to deploy and re-deploy these
drives to quickly deliver increased storage capacity, migrate data between systems, and easily manage
spare drives.
Pre-Failure Warranty means HP Insight Manager not only reports when a drive is going to fail but allows
replacement of failing drives prior to actual failure. For complete details, consult the HP Support Center
or refer to your HP Server documentation.
Seamless upgrades from past generations and upgrades to next generation HP high performance
and high capacity Serial Attached SCSI Smart Array controllers.
3G SAS (6G SAS Capable) technology delivers high performance and data bandwidth and
contains full compatibility with 1.5G SATA (3G SATA Capable) technology.
x8 5G PCI Express 2.0 host interface technology delivers high performance and data bandwidth
up to 5 GB/s maximum bandwidth.
Addition of the battery backed cache upgrade enables BBWC RAID 5, Capacity Expansion, RAID
migration, and Stripe Size Migration. Additionally, Smart Array Advanced Pack license key enables
RAID 6 (ADG), 6+0, Advanced Capacity Expansion, Mirror Splitting and Recombining in Offline
Mode, Drive Erase, Performance Optimization-Degraded Reads and Read Coalescing (VOD)
Mix-and-match SAS and SATA hard drives, lets you deploy drive technology as needed to fit your
computing environment.
Support for > 2 TB in a single logical drive.
Support for HP StorageWorks SAS tape and tape automation products.
Software consistency among all Smart Array family products: Array Configuration Utility (ACU),
Option ROM Configuration for Arrays (ORCA), Systems Insight Manager, Array Diagnostic Utility
(ADU) and SmartStart. Some of these features are not available with ProLiant 100 series platforms.
The SA-P212 controller supports up to 54 drives.
Low-profile PCI Express form factor - ships with a full size bracket for deployment in either a lowprofile or full sized slot
DA - 13203
Worldwide — Version 2 — February 13, 2009
Page 3
QuickSpecs
HP Smart Array P212 Controller
Standard Features
Online Management
Features
Online Capacity Expansion (with BBWC upgrade)
Advanced Capacity Expansion (with BBWC and SAAP license key)
Online RAID Level Migration (with BBWC upgrade)
Online Stripe Size Migration (with BBWC upgrade)
Mirror splitting and recombining (with SAAP license key)
Unlimited Global Online Spares Assignment
User Selectable Expand and Rebuild Priority
User Selectable RAID Level and Stripe Size
User Selectable Read and Write Cache Sizes
Ports
Eight (8) SAS physical links distributed across 1 internal x4/1 external x4 wide port connectors.
Performance
HP's High Performance Architecture sets new boundaries of industry performance expectations!
3G SAS (6G SAS Capable)
x8 3G SAS (6G SAS Capable) physical links (compatible with 1.5G SATA [3G SATA Capable])
256 MB DDR2-800 battery-backed cache provides up to 4.2 GB/s maximum bandwidth.
x8 5G PCI Express host interface provides 4 GB/s maximum bandwidth.
MIPS 32-bit Processor
Read ahead caching
Write-back caching (with battery-backed write cache upgrade)
Native Command
Queuing
Native Command Queuing (NCQ) is a technology designed to increase performance of SATA hard disk
drives by allowing the individual hard disk to internally optimize the order in which received read and
write commands are executed. This can reduce the amount of unnecessary going back-and-forth on the
drive's heads, resulting in increased performance for workloads where multiple simultaneous read/write
requests are outstanding, most often occurring in server or storage-type applications. Without NCQ the
drive has to process and complete one command at a time. For NCQ to be enabled, it must be
supported and turned on in the controller and in the hard drive itself.
NOTE: Please see the SATA Hard Drive QuickSpecs for specific SATA hard drive capacities that support
NCQ: http://h18000.www1.hp.com/products/quickspecs/11940_div/11940_div.html
Capacity
Given the increasing need for high performance and rapid capacity expansion, the SA-P212 offers:
Up to 6TB of total storage with 6 x 1TB SATA MDL hard drives (3.5")
NOTE: Support for greater than 2TB in a single logical drive. Additional capacity up to 180 with
an expander
Up to 1.168TB of total storage with 8 x 146GB SFF SAS hard drives
DA - 13203
Worldwide — Version 2 — February 13, 2009
Page 4
QuickSpecs
HP Smart Array P212 Controller
Standard Features
Availability
Provides increased server uptime by providing advanced storage functionality:
Online Capacity Expansion (with BBWC upgrade)
Online Advanced Capacity Expansion (with Smart Array Advanced Pack upgrade)
Online RAID Level Migration (with BBWC upgrade)
Online Stripe Size Migration (with BBWC upgrade)
Global Online Spare
Pre-Failure Warranty
Fault Prevention
The following features offer detection of possible failures before they occur, allowing preventive action to
be taken:
S.M.A.R.T.: Self Monitoring Analysis and Reporting Technology first developed at HP detects
possible hard disk failure before it occurs, allowing replacement of the component before failure
occurs.
Drive Parameter Tracking monitors drive operational parameters, predicting failure and notifying
the administrator.
Dynamic Sector Repairing continually performs background surface scans on the hard disk drives
during inactive periods and automatically remaps bad sectors, ensuring data integrity.
Smart Array Cache Tracking monitors integrity of controller cache, allowing pre-failure
preventative maintenance.
Fault Tolerance
Keeps data available and server running while a failed drive is being replaced; several fault
tolerance configurations are supported including:
RAID 6 with ADG (Advanced Data Guarding): This is the highest level of fault tolerance. It
allocates two sets of parity data across drives and allows simultaneous write operations. This level
of fault tolerance can withstand two simultaneous drive failures without downtime or data loss.
RAID 6+0:
6+0 Supported with min of 8 drives, but would have 4 available. Target benefit is to split
RAID across the external boxes.
NOTE: RAID 6, 6+0 is available only with the minimum of 256MB, Battery Kit, and Smart Array
Advanced Pack License Key option upgrades.
RAID 5 (Distributed Data Guarding): This allocates one set of parity data across drives and allows
simultaneous write operations. This level of fault tolerance can withstand a single drive failure
without downtime or data loss.
NOTE: RAID 5 is available with the 256MB & Battery Kit upgrade option.
RAID 5+0:
5+0 This is a RAID 0 array striped across 5 elements. Combines the straight block-level
striping of RAID 0 with the distributed parity of RAID 5.
RAID 1, 1+0 (Drive Mirroring): This allocates half of the drive array to data and the other half to
mirrored data, providing two copies of every file. It is a high-performance RAID.
DA - 13203
Worldwide — Version 2 — February 13, 2009
Page 5
QuickSpecs
HP Smart Array P212 Controller
Standard Features
Fault Recovery
Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure
On-Line Spares: There is no limit to the number of spare drives that can be installed prior to drive
failure. If a failure occurs, recovery begins with an On-Line Spare and data is reconstructed
automatically.
DRAM ECC corrects against single bit data and address corruption.
Battery-backed write cache upgrade provides for up to three days of battery power for data cache
retention. The data backup duration could be extended anytime the server's auxiliary power is
available during system power down.
Ease of Use
Consistency and Upgradeability make the Smart Array family unique in the industry:
GUI based configuration, management and diagnostic software tools
Common data format between generations of products
Data migration between servers and external StorageWorks Modular Smart Array enclosures
DA - 13203
Worldwide — Version 2 — February 13, 2009
Page 6
QuickSpecs
HP Smart Array P212 Controller
Compatibility
Server Compatibility:HP
SA-P212
For up to date compatibility, please see the following URL for complete Smart Array P212 Controller
compatibility and support information:
http://h18006.www1.hp.com/products/servers/proliantstorage/arraycontrollers/index.html
Operating Systems
Microsoft Windows 2003 x64 Edition
Microsoft Windows 2003 x84 Edition
Microsoft Windows 2008 Server x64
Microsoft Windows 2008 Server x84
Red Hat Enterprise Linux 4, 5 (x64 & x84)
SUSE Linux Enterprise Server 9 (x64 & x84)
SUSE Linux Enterprise Server 10 (x64 & x84)
SUSE Linux Enterprise Server 11 (x64 & x84)
Novell Netware 6.5 (Open Enterprise Server)
VMware
NOTE: For more Linux OS support & certification information, please visit our the ProLiant &
BladeSystem Server Linux matrix: http://h18004.www1.hp.com/products/servers/linux/hpLinuxcert.html
Software Suite
All Smart Array products share a common set of configuration, management and diagnostic tools,
including Array Configuration Utility (ACU), Array Diagnostic Utility (ADU), and Systems Insight
Manager. This software consistency of tools reduces the cost of training for each successive generation
of product and takes much of the guesswork out of troubleshooting field problems. These tools lower the
total cost of ownership by reducing training and technical expertise necessary to install and maintain HP
server storage.
Systems Insight Manager
Powerful server and server options/storage manager tool
Monitors over 1200 system wide parameters
Configuration/Diagnostic Utilities
SIM is only for the HP ProLiant 300, 500 and Blade series servers.
HP Array Configuration Utility (ACU)
Powerful Web based configuration utility for all Smart Array controllers
Provides a graphical view of HP drive array configurations.
Allows for management of multiple arrays over a secure internet connection from anywhere in the
world.
Easy to use Wizards for configuration
Runs offline for all supported Operating Systems on the ProLiant 300, 500 and Blade series and
runs online for Windows and Linux. For online configuration of NetWare, use CPQONLIN.
HP Option ROM Configuration for Arrays (ORCA)
A simple method for managing logical volumes during system power up by pressing F8 during
POST
Allows the ability to create arrays, logical volumes, and assign an online spare drive.
Allows the ability to view and delete logical volumes
Allows the ability to select the boot controller
For advanced array configurations use ACU
HP Array Diagnostic Utility (ADU)
DA - 13203
Worldwide — Version 2 — February 13, 2009
Page 7
QuickSpecs
HP Smart Array P212 Controller
Compatibility
In depth diagnostic and reporting utility for all Smart Array controllers
Runs offline for all supported Operating Systems, and runs online for Windows and Linux in HP
ProLiant 300, 500 and Blade series servers
DA - 13203
Worldwide — Version 2 — February 13, 2009
Page 8
QuickSpecs
HP Smart Array P212 Controller
Service and Support, HP Care Pack, and Warranty Information
Warranty
The warranty for this device is 3-years parts only.
Pre-Failure Warranty:
Warranty Drives attached to the Smart Array Controller and monitored under Insight
Manager are supported by a Pre-Failure (replacement) Warranty. For complete details, consult the HP
Support Center or refer to your HP Server Documentation.
Software Product Services Standalone telephone support
Rights to new license version
Media and documentation updates
Hardware Product
Services
Installation services
On-site maintenance (includes warranty support)
Response time upgrades during the warranty period
Post-warranty coverage
NOTE: For additional hardware installation and maintenance information, please refer to the URL:
http://www.hp.com/hps/hardware/
Warranty Upgrade
Options
Response - Upgrade on-site response from next business day to same day 4 hours
Coverage - Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days
Duration - Select duration of coverage for a period of 1, 3, or 5 years
Warranty upgrade options can come in the form of Care Packs, which are sold at the HP System level
this product attaches too
HP Care Pack Information HP Care Pack is defined as an upgrade to the product warranty attribute, available for a specific
duration and hours of coverage. Care Packs for this option is sold at the system level this option attaches
too.
HP Care Pack is not available for less than the product's warranty duration.
HP Care Pack is available for sale anytime during the warranty period for most products, but the
commencement date will be the same as the Warranty Start Date (delivery date to end user customer).
Proof of purchase may be required.
HP Care Pack services are prepaid.
NOTE: For additional HP Care Pack (hardware & software) information, as well as orderable part
numbers, please refer to the URL: http://www.hp.com/hps/carepack/
DA - 13203
Worldwide — Version 2 — February 13, 2009
Page 9
QuickSpecs
HP Smart Array P212 Controller
Related Options
NOTE: This is a list of related options. Some may be discontinued.
NOTE: Transfer rates of drives are dependent on the maximum transfer rate
Hard Drives
supported by the HBA or Controller. Refer to the HBA or Controller technical
specifications for details.
SAS Hot Plug SFF Enterprise (ENT) Drives
HP 300GB 3G SAS 10K SFF DP ENT HDD
HP 146GB 3G SAS 10K SFF DP ENT HDD
HP 72GB 3G SAS 15K SFF DP ENT HDD
HP 72GB 3G SAS 10K SFF DP ENT HDD
HP 36GB 3G SAS 15K SFF DP ENT HDD
SAS Hot Plug 3.5" Enterprise (ENT) Drives
HP 450GB 3G SAS 15K 3.5" DP ENT HDD
HP 400GB 3G SAS 10K 3.5" DP ENT HDD
HP 300GB 3G SAS 15K 3.5" DP ENT HDD
HP 146GB 3G SAS 15K 3.5" DP ENT HDD
HP 72GB 3G SAS 15K 3.5" DP ENT HDD
SAS Non-Hot Plug 3.5" Enterprise (ENT) Drives
HP 450GB 3G SAS 15K NHP 3.5" DP ENT HDD
HP 400GB 3G SAS 10K NHP 3.5" DP ENT HDD
HP 300GB 3G SAS 15K NHP 3.5" DP ENT HDD
HP 146GB 3G SAS 15K NHP 3.5" DP ENT HDD
SAS Hot Plug 3.5" Midline (MDL) Drives
HP 1TB 3G SAS 7.2K 3.5" DP MDL HDD
HP 750GB 3G SAS 7.2K 3.5" DP MDL HDD
SATA SFF Hot Plug Entry (ETY) Drives
HP 250GB 3G SATA 5.4K SFF ETY HDD
HP 120GB 1.5G SATA 5.4K SFF ETY HDD
SFF SATA Non-Hot Plug Entry (ETY) Drives
HP 2500GB 3G SATA 5.4K NHP SFF ETY HDD
HP 120GB 1.5G SATA 5.4K NHP SFF ETY HDD
SATA Hot Plug Midline (MDL) Drives
HP 1TB 3G SATA 7.2K 3.5" MDL HDD
HP 750GB 3G SATA 7.2K 3.5" MDL HDD
HP 500GB 3G SATA 7.2K 3.5" MDL HDD
HP 250GB 3G SATA 7.2K 3.5" MDL HDD
SATA Hot Plug Entry (ETY) Drives
HP 160GB 3G SATA 7.2K 3.5" ETY HDD
SATA Non-Hot Plug Midline (MDL) Drives
HP 750GB 3G SATA 7.2K NHP 3.5" MDL HDD
HP 500GB 3G SATA 7.2K NHP 3.5" MDL HDD
HP 250GB 3G SATA 7.2K NHP 3.5" MDL HDD
DA - 13203
Worldwide — Version 2 — February 13, 2009
492620-B21
418367-B21
418371-B21
384842-B21
418369-B21
454232-B21
459508-B21
416127-B21
384854-B21
384852-B21
454234-B21
508232-B21
417950-B21
417855-B21
461137-B21
461135-B21
460355-B21
458924-B21
460357-B21
459357-B21
454146-B21
458930-B21
458928-B21
458926-B21
458945-B21
462595-B21
458941-B21
458939-B21
Page 10
QuickSpecs
HP Smart Array P212 Controller
Related Options
SATA Non-Hot Plug Entry (ETY) Drives
HP 160GB 3G SATA 7.2K NHP 3.5" ETY HDD
NOTE: Go to the HP Hard Drive Compatibility table for complete drive compatibility
information (http://www.hp.com/products/harddiskdrives). Using hard drives in
unsupported configurations will result in voiding the warranty and could result in
damage to the drive and/or loss of data.
NOTE: There is a known compatibility issue with some early 3.5" SATA HDD that will
make them unable to be used with the SA-P400 controller. Customers should verify
that they are not using hard drive part number 332649-002/003 (spare 353042001), 332650-002/003 (spare 353043-001), or 356536-002/003 (spare 353044001).
NOTE: SATA Drive Write Cache is disabled by default to minimize the risk of data loss
in case of power loss and cannot be enabled for SATA drives attached to all HP Smart
Array controllers and HP 8 Port internal SAS/SATA HBA with RAID.
HP StorageWorks
Modular Smart Array
HP StorageWorks 70 Modular Smart Array
HP StorageWorks 60 Modular Smart Array
Tape Drives
DAT Tape Drives
HP StorageWorks DAT 160 SAS Internal Tape Drive
HP StorageWorks DAT 160 SAS External Tape Drive
LTO Ultrium Tape Drives
HP StorageWorks LTO-2 Ultrium 448 SAS Internal Tape Drive
HP StorageWorks LTO-2 Ultrium 448 SAS External Tape Drive
HP StorageWorks LTO-3 Ultrium 920 SAS Internal Tape Drive
HP StorageWorks LTO-3 Ultrium 920 SAS External Tape Drive
HP StorageWorks LTO-4 Ultrium 1760 SAS Internal Tape Drive
HP StorageWorks LTO-4 Ultrium 1760 SAS External Tape Drive
HP StorageWorks 1U SAS Rack-Mount Kit with one LTO-4 Ultrium 1760
HP StorageWorks LTO-4 Ultrium 1840 SAS Internal Tape Drive
HP StorageWorks LTO-4 Ultrium 1840 SAS External Tape Drive
Rack-mount Tape Drive Enclosures
HP StorageWorks 1U SAS Rack-Mount Kit
NOTE: The 1U SAS Rack-Mount Kit can support up to (2) half-height tape drives and
is compatible with the DAT 160 SAS, LTO-2 Ultrium 448 SAS, LTO-3 Ultrium 920
SAS and LTO-4 Ultrium 1760 SAS tape drives.
HP StorageWorks 3U SAS Rack-mount Kit
NOTE: The 3U Rack-mount Kit can support up to (2) full-height or (4) half-height tape
drives and compatible with multiple SAS tape drives including DAT 160 SAS, LTO-2
Ultrium 448 SAS, LTO-3 Ultrium 920 SAS, LTO-4 Ultrium 1760 SAS and LTO-4
Ultrium 1840 SAS tape drives.
Tape Autoloaders
HP StorageWorks 1/8 G2 LTO-4 Ultrium 1760 SAS Tape Autoloader
HP StorageWorks 1/8 G2 LTO-3 Ultrium 920 SAS Autoloader
DA - 13203
Worldwide — Version 2 — February 13, 2009
458947-B21
418800-B21
418408-B21
Q1587A
Q1588A
DW085A
DW086A
EH847A
EH848A
EH919A
EH920A
EH946A
EH860A
EH861A
AE459A
AG576A
AK377A
AH558A
Page 11
QuickSpecs
HP Smart Array P212 Controller
Related Options
Tape Libraries
HP StorageWorks MSL2024 1 LTO-4 Ultrium 1760 SAS Drive Library
HP StorageWorks MSL2024 1 LTO-3 Ultrium 920 SAS Drive Library
HP StorageWorks MSL4048 2 LTO-4 Ultrium 1760 SAS Drive Library
HP StorageWorks MSL4048 1 LTO-3 Ultrium 920 SAS Drive Library
HP StorageWorks MSL8096 2 LTO-4 Ultrium 1760 SAS Drive Library
HP StorageWorks MSL8096 2 LTO-3 Ultrium 920 SAS Drive Library
SAS Cables for Tape Drives
4M External Mini SAS to Mini SAS (SFF8088) 3x/1x External Split SAS Cable
NOTE: This split cable connects internally to SAS Hard Drive Cage (3x) and externally
to the HP Storage Works 1U SAS Rack-Mount Kit (1x) with other connector going to
internal SAS Controller port inside the server. Requires additional PCI slot on server
for threading 1x split cable to SAS tape.
2M External Mini-SAS (SFF8088) to Mini-SAS (SFF8088) 1x SAS Cable
NOTE: Use this cable to connect HP StorageWorks SAS external tape devices to HP
SAS controllers with external Mini-SAS (SFF8088) connectors.
4M External Mini-SAS (SFF8088) to Mini-SAS (SFF8088) 1x SAS Cable
NOTE: Use this cable to connect HP StorageWorks SAS external tape devices to HP
SAS controllers with external Mini-SAS (SFF8088) connectors.
4M External Mini-SAS (SFF8088) to Internal Mini-SAS (SFF8087) 3x/1x Split SAS
Cable
NOTE: This split cable connects internally to SAS Hard Drive Cage (3x) and externally
to the tape device (1x) with other connector attaching to the Smart Array P400i
controller inside a DL360 G5 or DL365 G5 server. The 1x cable occupies additional
PCI slot on the server.
2M External Mini-SAS (SFF8088) 1x to Mini-SAS (SFF8088) 4x fanout SAS Cable
NOTE: Use this cable to connect HP StorageWorks MSL SAS Tape Libraries to MiniSAS (SFF8088) ports.
4M External Mini-SAS (SFF8088) 1x to Mini-SAS (SFF8088) 4x fanout SAS Cable
NOTE: Use this cable to connect HP StorageWorks MSL SAS Tape Libraries to MiniSAS (SFF8088) ports.
HP StorageWorks Mini-SAS Cable for LTO Internal Tape Drive
HP StorageWorks Mini-SAS Cable for DAT Internal Tape Drive
Sas to Mini Sas Cables
Mini-SAS to Mini-SAS
Mini-SAS to Mini-SAS
Mini-SAS to Mini-SAS
Mini-SAS to SFF8484
Mini-SAS to SFF8484
Mini-SAS to SFF8484
Mini-SAS to SFF8484
12.75" & 18.00"
25.50" & 28.00"
33.00"
18.00"
24.00"
32.00"
35.00"
DA - 13203
Worldwide — Version 2 — February 13, 2009
AK378A
AH559A
AK380A
AH560A
AH382A
AH561A
AE464A
AE470A
AE465A
AG452A
AN975A
AN976A
AP746A
AP747A
496029-B21
496013-B21
496014-B21
496015-B21
496015-B21
496016-B21
496016-B21
Page 12
QuickSpecs
HP Smart Array P212 Controller
Technical Specifications
Dimensions (not including
bracket)
Disk Drive and Enclosure
Interface - transfer rate
SAS Connectors
Cache Memory Speed
Server Interface
SAS Speed
Cache Memory
Logical Volumes
Supported
Maximum Volume
Capacity
Host Memory Addressing
RAID Support
Low Profile PCIe Form Factor
19.05 cm x 24.13 cm x 5.72cm (7.5 in x 9.5 in x 2.25 in)
3G SAS (Serial Attached SCSI)/6G SAS Capable
1.5G SATA (Serial ATA)/3G SATA Capable
1 internal/1 external (Mini-SAS) x8 wide port connectors
DDR-2/800 MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s maximum bandwidth.
x8 5G PCIe 2.0 provides 4GB/s maximum bandwidth.
x8 3G SAS provides 2.4GB/s maximum bandwidth.
40-bit 256MB ECC protected cache; transportable with battery-backed upgrade.
NOTE: The 256MB cache is not battery-backed or transportable.
Up to 32 logical volumes
Upgradeable Firmware
6TB (6 x 1TB SATA 3.5" MDL HDD)
NOTE: Support for greater than 2TB in a single logical drive.
64-bit, supporting greater than 4GB server memory space
RAID 6, 6+0 (Advanced Data Guarding)
NOTE: The minimum of 256 MB cache, battery kit, and Smart Array Advanced Pack License Key
upgrade is required to enable RAID 6, 6+0
RAID 5, 5+0 (Distributed Data Guarding)
NOTE: The 256 MB & Battery Kit upgrade is required to enable RAID 5, 5+0 support
RAID 1, 1+0 (Striping & Mirroring)
RAID 0 (Striping)
Upgradeable Firmware with Recovery ROM feature
Environment-friendly
Products and Approach
End-of-life Management
and Recycling
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling
programs in many geographic areas. For trade-in information, please go to:
http://www.hp.com/go/green. To recycle your product, please go to:
http://www.hp.com/go/green or contact your nearest HP sales office.
Products returned to HP will be recycled, recovered or disposed of in a
responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide
treatment information for each product type for use by treatment facilities.
This information (product disassembly instructions) is posted on the Hewlett
Packard web site at: http://www.hp.com/go/green. These instructions may
be used by recyclers and other WEEE treatment facilities as well as HP OEM
customers who integrate and re-sell HP equipment.
© Copyright 2009 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. Microsoft and Windows are registered trademarks or
trademarks of Microsoft Corporation in the U.S. and/or other countries. The only warranties for HP products and services are set
forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as
constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
For hard drives, 1GB = 1 billion bytes. Actual formatted capacity is less.
DA - 13203
Worldwide — Version 2 — February 13, 2009
Page 13