Cerabar S PMC71, PMP71, PMP75 (Technical Information)

Technical Information
Cerabar S PMC71, PMP71, PMP75
Pressure transmitter
with ceramic and metal sensors
Overload-resistant and function-monitored; Communication via
HART, PROFIBUS PA or FOUNDATION Fieldbus
Application
Your benefits
The Cerabar S pressure transmitter is used for the
following measuring tasks:
• Absolute pressure and gauge pressure in gases, steams
or liquids in all areas of process engineering and
process measurement technology
• Level, volume or mass measurement in liquids
• High process temperature
– without diaphragm seals up to 150°C (302°F)
– with typical diaphragm seals up to 400°C (752°F)
• High pressure up to 700 bar
• International usage thanks to a wide range of approvals
• Very good reproducibility and long-term stability
• High reference accuracy: up to ±0.075%,
as PLATINUM version: ±0.05%
• Turn down 100:1, higher on request
• Used for process pressure monitoring up to SIL3,
certified according to IEC 61508 by TÜV SÜD
• HistoROM®/M-DAT memory module
• Function-monitored from the measuring cell to the
electronics
• Continuous modularity for differential pressure,
hydrostatic and pressure (Deltabar S – Deltapilot S –
Cerabar S), e.g.
– replaceable display
– universal electronic
• Quick commissioning thanks to quick setup menu
• Easy and safe menu-guided operation on-site,
via 4...20 mA with HART, via PROFIBUS PA or
via FOUNDATION Fieldbus
• Extensive diagnostic functions
• Device versions in conformity with ASME-BPE
TI383P/00/en/12.07
No. 71060099
Cerabar S
Table of contents
Function and system design. . . . . . . . . . . . . . . . . . . . . 4
Device selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Overview of diaphragm seal for PMP75 . . . . . . . . . . . . . . . . . . . . 5
Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Level measurement (level, volume and mass) . . . . . . . . . . . . . . . . 8
Communication protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Human interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
On-site display (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Operating elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
HistoROM®/M-DAT (optional) . . . . . . . . . . . . . . . . . . . . . . . . . 11
Functional Safety SIL/IEC 61508 Declaration of conformity (optional)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
On-site operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Handheld terminals – HART . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Handheld terminal DXR375 – FOUNDATION Fieldbus . . . . . . . 11
FieldCare . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Remote operation – FOUNDATION Fieldbus . . . . . . . . . . . . . . . 12
Commubox FXA291 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
ToF Adapter FXA291 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Measuring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Explanation of terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Signal range – 4...20 mA HART . . . . . . . . . . . . . . . . . . . . . . . . . 16
Signal on alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Load – 4...20 mA HART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Dynamic behavior current output . . . . . . . . . . . . . . . . . . . . . . . . 17
Dynamic behavior HART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Dynamic behavior PROFIBUS PA . . . . . . . . . . . . . . . . . . . . . . . . 18
Dynamic behavior FOUNDATION Fieldbus . . . . . . . . . . . . . . . . 18
Damping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Current consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Cable entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Cable specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Residual ripple . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Influence of power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Performance characteristics – general . . . . . . . . . . . . 23
Reference operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Uncertainty of measurement for small absolute pressure ranges . . 23
Long-term stability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Influence of the installation position . . . . . . . . . . . . . . . . . . . . . . 23
Performance characteristics – ceramic diaphragm. . . 24
Reference accuracy – PMC71 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Total performance – PMC71 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Total Error - PMC71 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2
Warm-up period – PMC71 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Thermal change of the zero output and the output span –
PMC71 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Performance characteristics – metallic diaphragm. . . 26
Reference accuracy – PMP71, PMP75 . . . . . . . . . . . . . . . . . . . .
Total performance – PMP71 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Total Error - PMP71 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warm-up period – PMP71, PMP75 . . . . . . . . . . . . . . . . . . . . . .
Thermal change of the zero output and the output span –
PMP71 and PMP75 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26
27
27
27
28
Operating conditions (installation) . . . . . . . . . . . . . . 29
General installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . 29
Installation instructions for devices without diaphragm seal – PMC71
and PMP71 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Heat insulation – PMC71 high temperature version and PMP75 . 29
Mounting with temperature isolator . . . . . . . . . . . . . . . . . . . . . . 30
Wall and pipe-mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
"Separate housing" version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Turn the housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Oxygen applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
LABS-free applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Ultra pure gas applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Diaphragm seals for materials with hydrogen build-up (Gold-Rhodium
coating) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Operating conditions (environment) . . . . . . . . . . . . . 33
Ambient temperature limits . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Climate class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Vibration resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electromagnetic compatibility . . . . . . . . . . . . . . . . . . . . . . . . . .
Overvoltage protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
33
33
33
33
33
34
34
Operating conditions (Process) . . . . . . . . . . . . . . . . . 35
Process temperature limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Process temperature range, seals . . . . . . . . . . . . . . . . . . . . . . . . 35
Pressure specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Mechanical construction . . . . . . . . . . . . . . . . . . . . . . 37
Housing dimensions T14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Housing dimensions T17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Process connections PMC71 (with ceramic measuring
diaphragm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Process connections PMP71 (with metallic measuring
diaphragm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PMP75 Basic unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Process connections PMP75 (with metallic measuring
diaphragm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
"Separate housing" version . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
37
37
38
45
52
52
65
66
66
Planning instructions, diaphragm seal systems . . . . . 68
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Endress+Hauser
Cerabar S
Planning instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diaphragm seal filling oils . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Influence of the temperature on the zero point . . . . . . . . . . . . . .
Ambient temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
68
69
69
73
73
Certificates and approvals . . . . . . . . . . . . . . . . . . . . . 75
CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ex approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Suitability for hygenic processes . . . . . . . . . . . . . . . . . . . . . . . .
Marine certificate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overspill protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CRN approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pressure Equipment Directive (PED) . . . . . . . . . . . . . . . . . . . . .
Standards and guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
75
75
75
75
75
75
75
76
Ordering information . . . . . . . . . . . . . . . . . . . . . . . . 77
PMC71 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PMC71 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PMC71 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PMC71 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PMP71 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PMP71 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PMP71 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PMP71 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PMP75 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PMP75 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PMP75 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PMP75 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PMP75 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
77
78
79
80
81
82
83
84
85
86
87
88
89
Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Innovation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Field of Activities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Brief operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manual for Functional Safety (SIL) . . . . . . . . . . . . . . . . . . . . . . .
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation/Control Drawings . . . . . . . . . . . . . . . . . . . . . . . . . .
Overspill protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
90
90
90
90
90
90
91
92
92
Endress+Hauser
Cerabar S
Function and system design
Device selection
Cerabar S –
Product family
PMC71
PMP75
PMP71
P01-PMC71xxx-16-xx-xx-xx-000
With capacitive measuring cell and
ceramic measuring diaphragm
(Ceraphire®)
P01-PMP71xxx-16-xx-xx-xx-000
With piezoresistive measuring cell
and metallic welded diaphragm
P01-PMP75xxx-16-xx-xx-xx-000
With diaphragm seal
Field of application
– Gauge pressure and absolute pressure – Gauge pressure and absolute pressure – Gauge pressure and absolute pressure
– Level
– Level
– Level
Process connections
–
–
–
–
Measuring ranges
from –100/0...100 mbar
to –1/0...40 bar
OPL 1
max. 60 bar
Diverse thread
DN 32 – DN 80
ANSI 1 1/2" – 4"
JIS 50 A – 100 A
Process temperature range
–25...+125°C/–20...+150°C
(–13...+257°F/–4...+302°F)
Ambient temperature range
–40...+85°C (–40...+185°F)
–
–
–
–
–
–
2
Diverse thread
DN 25 – DN 80
ANSI 1 1/2" – 4"
JIS 25 A – 100 A
Oval flange adapter
Prepared for diaphragm seal mount
– Wide range of diaphragm seals, → see
the following section "Overview of
diaphragm seal for PMP 75"
from –100/0...100 mbar
to –1/0...700 bar
from –400/0...400 mbar
to –1/0...400 bar
max. 1050 bar
max. 1050 bar
–40...+125°C
(–40...+257°F)
-70...400°C (-94...+752°F)
–40...+85°C (–40...+185°F) 3
–40...+85°C (–40...+185°F)
Ambient temperature range
separate housing
–40 to +60°C (–40 to +140°F)
Reference accuracy
– Up to ±0.075% of the set span
– PLATINUM version: up to ±0.05% of the set span
Up to ±0.075% of the set span
Supply voltage
– For non-hazardous areas: 10.5...45 V DC
– EEx ia: 10.5...30 V DC
Output
4...20 mA with superimposed HART protocol, PROFIBUS PA, FOUNDATION Fieldbus
Options
–
–
–
–
Specialities
– Metal-free measurement with PVDF – Oil volume-minimised process
connection
connections
– Cleaning of the transmitter for the use – gas-tight, elastomer-free
in paint shops
PMP71, PMP75: Gold-Rhodium-coated diaphragm
PMP71, PMP75: NACE-compliant materials
PMC71, PMP71, PMP75: inspection certificate 3.1
HistoROM®/M-DAT memory module
– Wide range of diaphragm seals
– For high media temperatures
– Oil volume-minimised process
connections
– Completely welded versions
1)
OPL = Over pressure limit; dependent on the lowest-rated element, with regard to pressure, of the selected components
2)
High temperature version "T" for feature 100 "Additional option 1" or for feature 110 "Additional option 2"
3)
lower temperature on request
4
Endress+Hauser
Cerabar S
Overview of diaphragm seal
for PMP75
Design
Diaphr. seal
Connection
Thread
Membrane
diaphragm seal
(MDM)
G
Version
Standard
Nominal diameter
Nom. press./Class
ISO 228
– G 1A
– G 1 1/2 A
– G 2A
700 bar
ANSI
– 1 MNPT
– 1 1/2 MNPT
– 2 MNPT
700 bar
ISO 2852
–
–
–
–
DN 25 (1")
DN 38 (1 1/2")
DN 51 (2")
DN 76.1 (3")
Dependent on the
clamp used
ISO 2852
– DN 25 (1")
– DN 38 (1 1/2")
– DN 51 (2")
Dependent on the
clamp used
Type N for pipes
DN 40 – DN 162
PN 40
DN50 (65 mm)
PN 25
DIN 11851
– DN 50
– DN 65
– DN 80
PN 25
DIN 11851
– DN 50
– DN 65
– DN 80
PN 25
ISO 2852
– DN 25 (1 1/2")
– DN 51 (2" )
Dependent on the
clamp used
– Type N for pipes
DN 40 – DN 162
PN 40
EN 1092-1/
DIN 2527
and
DIN 2501-1
–
–
–
–
–
–
–
–
ANSI flange
ANSI B 16.5
– 1", 2"
– 1 1/2", 3", 4"
JIS flange
B 2220
25A, 50A, 80A, 100A 10 K
EN/DIN flange
EN 1092-1/
DIN 2527
DN 50/DN 80 +
PN 10 – PN 40
50/100/200 mm ext.
diaphr. seal
ANSI B 16.5
2"/3"/4" + 2"/4"/6"/ Up to 300 lbs
8" ext. diaphr. seal
P01-PMP75xxx-03-xx-xx-xx-005
NPT
P01-PMP75xxx-03-xx-xx-xx-006
Tri-Clamp
Membrane
diaphragm seal
(MDM)
Clamp
Pipe diaphragm
seal (RDM)
Clamp
P01-FMD78xxx-03-xx-xx-xx-005
P01-FMD78xxx-03-xx-xx-xx-009
Hygienic
connections
Membrane
diaphragm seal
(MDM)
Varivent
(EHEDG and 3A
approval)
P01-FMD78xxx-03-xx-xx-xx-007
DRD
P01-FMD78xxx-03-xx-xx-xx-006
Taper adapter with
coupling nut
P01-FMD78xxx-03-xx-xx-xx-003
Threaded adapter
P01-FMD78xxx-03-xx-xx-xx-004
Versions in
Membrane
conformity with
diaphragm seal
ASME-BPE for use (MDM)
in biotechnical
processes;
wetted surfaces
Ra ≤ 0.4 μm
(15.75 μin;
180 grit),
electropolished
Clamp
Flange
EN/DIN flange
Membrane
diaphragm seal
(MDM)
P01-PMP46xxx-03-xx-xx-xx-005
Varivent
(EHEDG and 3A
approval)
P01-PMP46xxx-03-xx-xx-xx-004
DN 25, DN 50
DN 32, DN 40
DN 80
DN 100
up to PN 400
PN 40
up to PN 100
PN 100
P01-PMP75xxx-03-xx-xx-xx-001
Flange with
extended
diaphragm seal
Membrane
diaphragm seal
(MDM)
ANSI flange
Endress+Hauser
P01-PMP75xxx-03-xx-xx-xx-002
– 2500 lbs
– 300 lbs
5
Cerabar S
Design
Diaphr. seal
Connection
Threaded
connection with
separator
Membrane
diaphragm seal
(MDM)
G
Version
Standard
Nominal diameter
Nom. press./Class
ISO 228/
EN837
– G 1/2 A
– G 1/2 B
– 160 bar
– 400 bar
ANSI
– 1/2 MNPT
– 160 bar
– 400 bar
ANSI
– 1/2 FNPT
– 1 FNPT
250 bar
P01-PMP75xxx-03-xx-xx-xx-004
NPT
P01-PMP75xxx-03-xx-xx-xx-008
NPT Off line thread
P01-PMP75xxx-03-xx-xx-xx-009
6
Endress+Hauser
Cerabar S
Measuring principle
Ceramic measuring diaphragm used for PMC71 (Ceraphire®)
➀
➁
Metallic measuring diaphragm used for
PMP71 and PMP75
➂
➀
➁
➃
➂
➃
p
p
P01-PMC71xxx-03-xx-xx-xx-000
P01-PMP7xxxx-03-xx-xx-xx-000
Ceramic sensor
Metal sensor
1
2
3
4
1
2
3
4
Atmospheric vent (gauge pressure only)
Ceramic substrate
Electrodes
Ceramic diaphragm
Measuring element
Measuring diaphragm with Wheatstone bridge
Channel with fill fluid
Process diaphragm, Metal separating diaphragm
Ceramic measuring diaphragm used for PMC71 (Ceraphire®)
The ceramic sensor is a dry sensor, i.e. the process pressure acts directly on the robust ceramic diaphragm and
deflects it. A pressure-dependent change in capacitance is measured at the electrodes of the ceramic carrier and
the diaphragm. The measuring range is determined by the thickness of the ceramic diaphragm.
Advantages:
• Guaranteed overload resistance up to 40 times the nominal pressure
• Thanks to highly-pure 99.9% ceramic (Ceraphire®, see also "www.endress.com/ceraphire")
– extremely high chemical resistance compared to Alloy
– less relaxation
– high mechanical stability
• Suitable for vacuums
• Second process barrier (Secondary Containment) for enhanced integrity
• Process temperature up to 150°C (302°F)
Metallic measuring diaphragm used for PMP71 and PMP75
PMP71
The operating pressure deflects the separating diaphragm and a fill fluid transfers the pressure to a resistance
measuring bridge (semi-conductor technology). The pressure-dependent change of the bridge output voltage
is measured and evaluated.
Advantages:
• Can be used with process pressures up to 700 bar
• High long-term stability
• Guaranteed overload resistance up to 4 times the nominal pressure
• Second process barrier (Secondary Containment) for enhanced integrity
• Significantly less thermal effect compared to diaphragm seal systems
PMP75
The operating pressure acts on the diaphragm of the diaphragm seal and is transferred to the separating
diaphragm of the sensor by a diaphragm seal fill fluid. The separating diaphragm is deflected and a fill fluid
transfers the pressure to a resistance measuring bridge. The pressure-dependent change of the bridge output
voltage is measured and evaluated.
Advantages:
• Can be used with process pressures up to 400 bar
• High long-term stability
• Guaranteed overload resistance up to 4 times the nominal pressure
• Second process barrier (Secondary Containment) for enhanced integrity
Endress+Hauser
7
Cerabar S
Level measurement (level,
volume and mass)
Design and operation mode
p
h= ρ g
h
P01-PMx7xxxx-15-xx-xx-xx-000
Level measurement with Cerabar S
h
p
ρ
g
Height (level)
Pressure
Density of the medium
Gravitation constant
Your benefits
•
•
•
•
•
Communication protocol
8
Choice of three level operating modes in the device software
Volume and mass measurements in any tank shapes by means of a freely programmable characteristic curve
Choice of diverse level units with automatic unit conversion
A customised unit can be specified
Has a wide range of uses, as well
– in the event of foam formation
– in tanks with agitators of screen fittings
– in the event of liquid gases
• 4...20 mA with HART communication protocol
• PROFIBUS PA
– The Endress+Hauser devices meet the requirements as per the FISCO model.
– Due to the low current consumption of 11 mA ± 1 mA
– up to 9 Cerabar S for EEx ia, CSA IS and FM IS applications
– up to 32 Cerabar S for all other applications, e.g. in non-hazardous areas, EEx nA, etc.
can be operated at one bus segment with installation as per FISCO.
Further information on PROFIBUS PA, such as requirements for bus system components, can be found in
the Operating Instructions BA034S "PROFIBUS DP/PA: Guidelines for planning and commissioning" and in
the PNO guideline.
• FOUNDATION Fieldbus
– The Endress+Hauser devices meet the requirements as per the FISCO model.
– Due to the low current consumption of 14 mA ± 1 mA
– up to 7 Cerabar S for EEx ia, CSA IS and FM IS applications
– up to 30 Cerabar S for all other applications, e.g. in non-hazardous areas, EEx nA, etc.
can be operated at one bus segment with installation as per FISCO.
Further information on FOUNDATION Fieldbus, such as requirements for bus system components can be
found in the Operating Instructions BA013S "FOUNDATION Fieldbus Overview".
Endress+Hauser
Cerabar S
Human interface
On-site display (optional)
A 4-line liquid crystal display (LCD) is used for display and operation. The on-site display shows measured
values, dialog text as well as fault and notice messages in plain text, thereby supporting the user in every stage
of operation.
4...20 mA HART and PROFIBUS PA
Functions:
• 8-digit measured value display including sign and decimal point, bar graph for 4 to 20 mA HART as current
display or for PROFIBUS PA as graphical display of the scaled value of the AI Block
• Simple and complete menu guidance thanks to separation of the parameters into three levels
• Each parameter is given a 3-digit ID number for easy navigation.
• Option for configuring the display according to individual requirements and desires, such as language,
alternating display, display of other measured values such as sensor temperature, contrast setting
• Comprehensive diagnostic functions (fault and warning message, peak-hold indicators, etc.)
• Rapid and safe commissioning with the Quick Setup menu
Measured value display
Function name
Value
Parameter
Identification
number
Header line
Main line
Information
line
–
+
E
Unit
Symbol
Bargraph
Editing modes
Operating keys
Selection
options
Value that
can be edited
Current measured value
P01-xxxxxxxx-07-xx-xx-en-011
FOUNDATION Fieldbus
Functions:
• 8-digit measured value display including sign and decimal point, bargraph for current display
• Option for configuring the display according to individual requirements and desires, such as language,
alternating display, display of other measured values such as sensor temperature, contrast setting
• Comprehensive diagnostic functions (fault and warning message)
Measured value display
Function name
Value
Parameter
Identification
number
Header line
Main line
Information
line
Unit
Symbol
Bargraph
P01-xMD7xxxx-07-xx-xx-xx-001
Endress+Hauser
9
Cerabar S
Operating elements
With regard to T14 housings, the operating keys are located either outside the device under the protection cap
or inside on the electronic insert. In T17 housings, the operating keys are always located inside on the
electronic insert.
In addition, devices with an on-site display and a 4 to 20 mA HART or PROFIBUS PA electronic insert have
operating keys on the on-site display.
Operating keys on the exterior of the device
4...20 mA HART
PROFIBUS PA/
FOUNDATION Fieldbus
0%
Zero
P01-PMx7xxxx-19-xx-xx-xx-038
The operating keys located externally on the device work on the Hall sensor principle. As a result, no additional
openings are required in the device. This guarantees:
• Complete protection against environmental influences such as moisture and contamination
• Simple operation without any tools
• No wear.
Operating keys and elements located internally on the electronic insert
➅➆
off
➀
off
➂
➁
on
off
0%
Display
2
on
on
off
off
ON
CK S D A 0
2
3
4
5
6
7
HW-Version:
SW-Version:
P01-xxxxxxxx-19-xx-xx-xx-104
1
2
250002272-–
1
2
250002271-–
HW-Version:
SW-Version:
Display
1
2
HW
off
PC
PC
R
FIELD COMMUNICATION PROTOCOL
➃
0%
Sensor
8
8
1 2 3 4 5 6 7 8
Address
SW
HW
HART
2
on
1
PC
1
2
➁ ➂
Zero
Histo ROM
➂
1
1
➄
Zero
Sensor
➀
➃
TM
FOUNDATION
HW-Version:
SW-Version:
P01-xxxxxxxx-19-xx-xx-xx-105
1
2
P01-xxxxxxxx-19-xx-xx-xx-106
Electronic insert HART
Electronic insert PROFIBUS PA
Electronic insert FOUNDATION Fieldbus
1
2
3
4
1
2
3
4
5
6
1
2
3
4
5
5
6
Operating keys
Slot for optional display
Slot for optional HistoROM®/M-DAT
DIP-switch for locking/unlocking
measured-value-relevant parameters
DIP-switch for damping on/off
Green LED to indicate value being accepted
7
10
Green LED to indicate value being accepted
Key for position calibration and device reset
DIP-switch for bus address
Slot for optional display
Slot for optional HistoROM®/M-DAT
DIP-switch for locking/unlocking measuredvalue-relevant parameters
DIP-switch for damping on/off
Histo ROM
➁
➄➅
t
250002273-–
➀
on
Simulation
on
➅
t
Sim.
➃➄
6
Green LED to indicate value being accepted
Key for position calibration
Slot for optional display
Slot for optional HistoROM®/M-DAT
DIP-switch for locking/unlocking
measured-value-relevant parameters
DIP-switch for simulation mode on/off
Endress+Hauser
Cerabar S
HistoROM®/M-DAT
(optional)
HistoROM®/M-DAT is a memory module, which is attached to the electronic insert. The HistoROM®/M-DAT
can be retrofitted at any stage (Order number: 52027785).
Your benefits
• Quick and safe commissioning of the same measuring points by copying the configuration data of one
transmitter to another transmitter
• Reliable process monitoring thanks to cyclical recording of pressure and sensor temperature measured values
• Simple diagnosis by recording diverse events such as alarms, configuration changes, counters for measuring
range undershoot and overshoot for pressure and temperature as well as user limit overshoot and undershoot
for pressure and temperature etc.
• Analysis and graphic evaluation of the events and process parameters via software (contained in scope of
supply).
HistoROM®/M-DAT can be ordered via feature 100 "Additional options 1" or feature 110 "Additional
options 2" or as spare parts. → See also page 77 ff. A CD with an Endress+Hauser operating program is also
included in the scope of delivery.
You can copy data from one transmitter to another transmitter when operating a FOUNDATION Fieldbus
device via an FF configuration program. You need the Endress+Hauser ToF Tool operating program and the
Commubox FXA291 service interface and the ToF Adapter FXA291 to be able to access the data and events
saved in the HistoROM®/M-DAT.
Functional Safety SIL/
IEC 61508 Declaration of
conformity (optional)
The Cerabar S pressure transmitters with 4...20 mA output signal have been developed to IEC 61508 standard
and have been certified by TÜV SÜD. These devices can be used for process pressure monitoring up to SIL3.
→ For a detailed description of the safety functions with Cerabar S, settings and characteristic quantities for
functional safety, please refer to the "Functional Safety Manual - Cerabar S" SD190P.
→ For devices with SIL2/IEC 61508 declaration of conformity, see page 80 ff, Feature 100 "Additional
option 1" and Feature 110 "Additional option 2", version E "SIL2/IEC 61508, Declaration of Conformity".
On-site operation
Functions 4...20 mA HART and PROFIBUS PA
• With on-site display: navigate through the operating menu using three operating keys
• Without on-site display:
– Position calibration (zero point correction)
– Setting lower-range value and upper-range value – reference pressure present at device (HART only)
– Value acceptance indicated by green LED
• Device reset
• Locking and unlocking measured-value-relevant parameters
• Switching damping on and off
• Setting bus address (PROFIBUS PA only)
Functions FOUNDATION Fieldbus
•
•
•
•
Position calibration (zero point correction)
Value acceptance indicated by green LED
Locking and unlocking measured-value-relevant parameters
Switching simulation mode on and off
Handheld terminals – HART
With a handheld terminal, all the parameters can be configured anywhere along the 4...20 mA line via menu
operation.
Handheld terminal DXR375 –
FOUNDATION Fieldbus
With a handheld terminal DXR375, all the parameters can be configured via menu operation.
Endress+Hauser
11
Cerabar S
FieldCare
FieldCare is an Endress+Hauser asset management tool based on FDT technology. With FieldCare, you can
configure all Endress+Hauser devices as well as devices from other manufacturers that support the FDT
standard. The following operating systems are supported: WinNT4.0, Win2000 and Windows XP.
FieldCare supports the following functions:
• Configuration of transmitters in offline and online operation
• Loading and saving device data (upload/download)
• HistoROM®/M-DAT analysis
• Documentation of the measuring point
Connection options:
• HART via Commubox FXA191 and the RS 232 C serial interface of a computer
• HART via Commubox FXA195 and the USB port on a computer
• PROFIBUS PA via segment coupler and PROFIBUS interface card
• Service interface with adapter Commubox FXA291 and ToF Adapter FXA291 (USB).
Remote operation –
FOUNDATION Fieldbus
An FF configuration program is required to integrate a device with "FOUNDATION Fieldbus signal" into an FF
network or to set the FF-specific parameters. Please contact your local Endress+Hauser Sales Center for more
information.
Commubox FXA291
The Commubox FXA291 connects Endress+Hauser field instruments with CDI interface (= Endress+Hauser
Common Data Interface) to the USB interface of a personal computer or a notebook. For details refer to
TI405C/07/en.
!
Note!
For the following Endress+Hauser instruments you need the "ToF Adapter FXA291" as an additional accessory:
• Cerabar S PMC71, PMP7x
• Deltabar S PMD7x, FMD7x
• Deltapilot S FMB70
ToF Adapter FXA291
12
The ToF Adapter FXA291 connects the Commubox FXA291 via the USB interface of a personal computer or
a notebook. For details refer to KA271F/00/a2.
Endress+Hauser
Cerabar S
Input
Measured variable
Absolute pressure and gauge pressure, from which level (level, volume or mass) is derived
Measuring range
PMC71 – with ceramic measuring diaphragm (Ceraphire®) for gauge pressure
Nominal
value
Measurement limit
Smallest
calibratable
Span 4
MWP 1
OPL 2
Vacuum
resistance
Versions in
the order
code 3
lower (LRL)
upper (URL)
[bar]
[bar]
[bar]
[bar]
[bar]
[barabs]
100 mbar
–0.1
+0.1
0.005
2.7
4
0.7
1C
250 mbar
–0.25
+0.25
0.005
3.3
5
0.5
1E
400 mbar
–0.4
+0.4
0.005
5.3
8
0
1F
1 bar
–1
+1
0.01
6.7
10
0
1H
2 bar
–1
+2
0.02
12
18
0
1K
4 bar
–1
+4
0.04
16.7
25
0
1M
10 bar
–1
+10
0.1
26.7
40
0
1P
40 bar
–1
+40
0.4
40
60
0
1S
PMC71 – with ceramic measuring diaphragm (Ceraphire®) for absolute pressure
Nominal
value
Smallest
calibratable
Span 4
MWP 1 OPL 2
Versions in the order code 3
lower (LRL)
upper (URL)
[barabs]
[barabs]
[bar]
[barabs] [barabs]
100 mbar
0
+0.1
0.005
2,7
4
2C
250 mbar
0
+0.25
0.005
3,3
5
2E
400 mbar
0
+0.4
0.005
5,3
8
2F
1 bar
0
+1
0.01
6.7
10
2H
2 bar
0
+2
0.02
12
18
2K
4 bar
0
+4
0.04
16.7
25
2M
10 bar
0
+10
0.1
26.7
40
2P
40 bar
0
+40
0.4
40
60
2S
1)
2)
3)
4)
Endress+Hauser
Measurement limit
The MWP (maximum working pressure) for the measuring device depends on the weakest element of the
components selected with regard to pressure, i.e. the process connection (→ see page 37 ff) has to taken into
consideration in addition to the sensor (→ see Table above). Pay attention to the pressure-temperature dependence
also. For the appropriate standards and further information, see page 36, "Pressure specification".
OPL: Over Pressure Limit; depends on the weakest link in terms of pressure of the selected components.
Versions in the order code → See also page 78 ff, feature 40 "Sensor range; Sensor overload limit (= OPL)"
Turn down > 100:1 on request or can be set at the device
13
Cerabar S
PMP71 and PMP75 – with metallic measuring diaphragm for gauge pressure
Nominal
value
Measurement
limits
Smallest
calibratable
Span 5
MWP 1
OPL 2
Vacuum
resistance 3
Versions in
the order
code 4
lower
(LRL)
upper
(URL)
Silicone oil/
Inert oil
[bar]
[bar]
[bar]
[barrel]
[barrel]
[barabs]
100 mbar 6
–0.1
+0.1
0.005
2.7
4
0.01/0.04
1C
250 mbar 6
–0.25
+0.25
0.005
2.7
4
0.01/0.04
1E
400 mbar
–0.4
+0.4
0.005
4
6
0.01/0.04
1F
1 bar
–1
+1
0.01
6.7
10
0.01/0.04
1H
2 bar
–1
+2
0.02
13.3
20
0.01/0.04
1K
4 bar
–1
+4
0.04
18.7
28
0.01/0.04
1M
10 bar
–1
+10
0.1
26.7
40
0.01/0.04
1P
40 bar
–1
+40
0.4
100
160
0.01/0.04
1S
100 bar
–1
+100
1.0
100
400
0.01/0.04
1U
400 bar
–1
+400
4.0
400
600
0.01/0.04
1W
700 bar 6
–1
+700
7.0
700
1050
0.01/0.04
1X
PMP71 and PMP75 – with metallic measuring diaphragm for absolute pressure
Nominal
value
lower
(LRL)
upper
(URL)
Smallest
calibratable
Span 5
MWP 1
OPL 2
Vacuum
resistance 3
Versions in
the order
code 4
Silicone oil/
Inert oil
[barabs]
[barabs]
[bar]
[barabs]
[barabs]
[barabs]
100 mbar
6
0
+0.1
0.005
2.7
4
0.01/0.04
2C
250 mbar
6
0
+0.25
0.005
2.7
4
0.01/0.04
2E
400 mbar
0
+0.4
0.005
4
6
0.01/0.04
2F
1 bar
0
+1
0.01
6.7
10
0.01/0.04
2H
2 bar
0
+2
0.02
13.3
20
0.01/0.04
2K
4 bar
0
+4
0.04
18.7
28
0.01/0.04
2M
10 bar
0
+10
0.1
26.7
40
0.01/0.04
2P
40 bar
0
+40
0.4
100
160
0.01/0.04
2S
100 bar
0
+100
1.0
100
400
0.01/0.04
2U
0
+400
4.0
400
600
0.01/0.04
2W
0
+700
7.0
700
1050
0.01/0.04
2X
400 bar
700 bar
1)
2)
3)
4)
5)
6)
14
Measurement
limits
6
The MWP (maximum working pressure) for the measuring device depends on the weakest element of the
components selected with regard to pressure, i.e. the process connection (→ see page 37 ff) has to taken into
consideration in addition to the sensor (→ see Table above). Pay attention to the pressure-temperature dependence
also. Pay attention to the pressure-temperature dependence also. For the appropriate standards and further
information, see Page 36, "Pressure specification".
OPL: Over pressure limit (= Sensor overload limit)
The vacuum resistance applies to the measuring cell at a reference conditions. The pressure and temperature
application limits of the selected filling oil must also be observed for the PMP75. → See also page 69, section
"Diaphragm seal filling oils".
Versions in the order code → See also page 77 ff, feature 40 "Sensor range; Sensor Overload limit (= OPL)"
Turn down > 100:1 on request or can be set at the device
PMP71 only, PMP75 on request
Endress+Hauser
Cerabar S
Explanation of terms
Explanation of terms: Turn down (TD),
set span and on zero based span
Case 1:
• ⏐Lower range value (LRV)⏐ ≤ ⏐Upper range value (URV)⏐
Example:
• Lower range value (LRV) = 0 bar
• Upper range value (URV) = 0.5 bar
• Nominal value (URL) = 1 bar
➀=➁
LRL = LRV
URV
URL
0 bar
0.5 bar
+1 bar
Turn down:
• TD = URL / ⏐URV⏐ = 2:1
➂
set span:
• URV – LRV = 0.5 bar
This span is based on the zero point.
➃=➄
P01-PMx7xxxx-05-xx-xx-xx-012
Example: 1 bar measuring cell
Case 2:
• ⏐Lower range value (LRV)⏐ ≤ ⏐Upper range value (URV)⏐
Example:
• Lower range value (LRV) = 0 bar
• Upper range value (URV) = 0.5 bar
• Nominal value (URL) = 1 bar
➀=➁
LRV
LRL
0
–1 bar
URV
0.5 bar
Turn down:
• TD = URL / ⏐URV⏐ = 2:1
URL
+1 bar
➂
➃
set span:
• URV – LRV = 0.5 bar
This span is based on the zero point.
➄
P01-PMx7xxxx-05-xx-xx-xx-007
Example: 1 bar measuring cell
Case 3:
• ⏐Lower range value⏐ ≥ ⏐Upper range value⏐
Example:
• Lower range value (LRV) = –0.6 bar
• Upper range value (URV) = 0 bar
• Nominal value (URL) = 1 bar
➀=➁
LRL
–1 bar
LRV
URV
URL
–0.6 bar
0
+1 bar
Turn down:
• TD = URL / ⏐LRV⏐ = 1,67:1
➂
➃
set span:
• URV – LRV = 0.6 bar
This span is based on the zero point.
➄
P01-PMx7xxxx-05-xx-xx-xx-008
Example: 1 bar measuring cell
1
2
3
4
5
LRL
URL
LRV
URV
Endress+Hauser
Set span
Zero based span
Nominal value i Upper range limit (URL)
Nominal measuring range
Sensor measuring range
Lower range limit
Upper range limit
Lower range value
Upper range value
15
Cerabar S
Output
Output signal
• 4...20 mA with superimposed digital communication protocol HART 5.0, 2-wire
• Digital communication signal PROFIBUS PA (Profile 3.0), 2-wire
• Digital communication signal FOUNDATION Fieldbus, 2-wire
Signal range –
4...20 mA HART
3.8 mA to 20.5 mA
Signal on alarm
• 4...20 mA HART
Options:
– Max. alarm*: can be set from 21...23 mA
– Keep measured value: last measured value is kept
– Min. alarm: 3.6 mA
* Factory setting: 22 mA
• PROFIBUS PA: can be set in the Analog Input block,
options: Last Valid Out Value, Fsafe Value (factory setting), Status bad
• FOUNDATION Fieldbus: can be set,
options: Last good Value, Fail Safe Value (factory setting), Wrong Value
Load – 4...20 mA HART
➀
Test
RLmax ≤
RLmax
[Ω]
1500
U – 10.5 V
23 mA
➁
Test
1282
RLmax ≤
RLmax
[Ω]
U – 11.5 V
23 mA
1456
1239
847
804
➃
413
➂
10.5
RLmax
[Ω]
1478
➃
➂
369
40 45 U
[V]
20
30
RLmax ≤
U – 11 V
23 mA
11.5
20
RLmax ≤
RLmax
[Ω]
40 45 U
[V]
30
U – 12 V
23 mA
1434
1260
1217
826
782
➄
391
11
20
30
➄
347
40 45 U
[V]
12
20
30
40 45 U
[V]
P01-PMx7xxxx-05-xx-xx-xx-003
Load diagram, observe the position of the jumper and the explosion protection. (→ See also page 22, section "Taking
4...20 mA test signal" .)
1
2
3
4
5
RLmax
U
Jumper for the 4...20 mA test signal inserted in "Non-test" position
Jumper for the 4...20 mA test signal inserted in "Test" position
Supply voltage 10.5 (11.5)...30 V DC for 1/2 G, 1 GD, 1/2 GD, FM IS, CSA IS, IECEx ia, NEPSI Ex ia
Supply voltage10.5 (11.5)...45 V DC for devices for non-hazardous areas, 1/2 D, 1/3 D, 2 G EEx d, 3 G EEx nA,
FM XP, FM DIP, FM NI, CSA XP, CSA Dust-Ex, NEPSI Ex d
Supply voltage 11 (12)...45 V DC for PMC71, EEx d[ia], NEPSI Ex d[ia]
Maximum load resistance
Supply voltage
Note!
When operating via a handheld terminal or via PC with an operating program, a minimum communication
resistance of 250 Ω must exist within the loop.
16
Endress+Hauser
Cerabar S
Resolution
• Current output: 1 μA
• Display: can be set (setting at the factory: presentation of the maximum accuracy of the transmitter)
Dynamic behavior
current output
Dead time, Time constant (T63)
I
100 %
63 %
t1
t2
t
P01-xxxxxxxx-05-xx-xx-xx-007
Presentation of the dead time and the time constant
Dynamic behavior HART
Type
Dead time t1
Time constant (T63), t2
PMC71
90 ms
120 ms
PMP71
45 ms
• 100 mbar, 250 mbar, 400 mbar measuring cell: 70 ms
• measuring cells ≥ 1 bar: 35 ms
PMP75
PMP71 + influence from the diaphragm seal
Dead time, Time constant (T63)
A typical cyclic parametrization for the PLC of 20 values per second results in the following total dead time:
Type
Dead time t1
Time constant (T63), t2
PMC71
90 ms
120 ms
PMP71
45 ms
• 100 mbar, 250 mbar, 400 mbar measuring cell: 70 ms
• measuring cells ≥ 1 bar: 35 ms
PMP75
PMP71 + influence from the diaphragm seal
Reading cycle
• HART commands: on average 3 to 4 per second
Cycle time (Update time)
On average 250...330 ms.
Response time
≤ 250 ms
Endress+Hauser
17
Cerabar S
Dynamic behavior
PROFIBUS PA
Dead time, Time constant (T63)
A typical cyclic parametrization for the PLC of 20 values per second results in the following total dead time:
Type
Dead time t1
Time constant (T63), t2
PMC71
340 ms
120 ms
PMP71
295 ms
• 100 mbar, 250 mbar, 400 mbar measuring cell: 70 ms
• measuring cells ≥ 1 bar: 35 ms
PMP75
PMP71 + influence from the diaphragm seal
Reading cycle
cyclic:
• max.: 100/s
• typical value: 20/s
acyclic:
• max.: 20/s
• typical value: 10/s
Cycle time (Update time)
• The cycle time in a bus segment in cyclic data communication depends on the number of devices, on the
segment coupler used and on the internal PLC cycle time.
• The minimum cycle time is approx. 20 ms per device.
Response time
• cyclic: approx. 10 ms per request
• acyclic: < 50 ms
All values are typical values.
Dynamic behavior
FOUNDATION Fieldbus
Dead time, Time constant (T63)
If the macro cycle time (of the PLC) is set to a typical value of 250 ms, the following total dead time results:
Type
Dead time t1
Time constant (T63), t2
PMC71
340 ms
120 ms
PMP71
295 ms
• 100 mbar, 250 mbar, 400 mbar measuring cell: 70 ms
• measuring cells ≥ 1 bar: 35 ms
PMP75
PMP71 + influence from the diaphragm seal
Reading cycle
• cyclic: up to 5/s, dependent on the number and type of function blocks used in a closed-control loop
• acyclic: 10/s
Cycle time (Update time)
250 ms
Response time
• cyclic: < 80 ms
• acyclic: < 40 ms
All values are typical values.
18
Endress+Hauser
Cerabar S
Damping
A damping affects all outputs (output signal, display).
• Via on-site display, handheld terminal or PC with operating program, continuous from 0...999 s
• Additionally for HART and PROFIBUS PA: via DIP-switch on the electronic insert, switch position
"on" = set value and "off"
• Factory setting: 2 s
Endress+Hauser
19
Cerabar S
Power supply
Electrical connection
Note!
• When using the measuring device in hazardous areas, installation must comply with the corresponding
national standards and regulations and the Safety Instructions or Installation or Control Drawings. → See
also page 67 ff, sections "Safety Instructions" and "Installation/Control Drawings".
• Devices with integrated overvoltage protection must be earthed. → See also page 34.
• Protective circuits against reverse polarity, HF influences and overvoltage peaks are installed.
4...20 mA HART
➀
➅
➆
10.5 V DC
11.5 V DC
4…20 mA
Test
Test
➁
Test
4... 20mA
➄
➂
Test
4... 20mA
➇
➃
P01-xMx7xxxx-04-xx-xx-xx-001
Electrical connection 4...20 mA HART
1
2
3
4
5
6
7
8
Housing
Jumper for 4...20 mA test signal
→ See also page 22, section "Taking 4...20 mA test signal".
Internal earth terminal
External earth terminal
4...20 mA test signal between plus and test terminal
Minimum supply voltage 10.5 V DC, if the jumper is inserted in accordance with the illustration.
Minimum supply voltage 11.5 V DC, if the jumper is inserted in "Test" position.
Devices with integrated overvoltage protection are labelled OVP (overvoltage protection) here (→ see also page 34).
PROFIBUS PA
The two-wire cable must be connected to the "PA+" and "PA–" terminals.
FOUNDATION Fieldbus
The two-wire cable must be connected to the "FF+" and "FF–" terminals.
Devices with Harting plug Han7D
+
Cerabar S
+ –
–
7
8
6
1
2
Han7D
5
3
4
+ –
P01-PMx7xxxx-04-xx-xx-xx-001
Left: electrical connection for devices with Harting plug Han7D
Right: view of the plug connector at the device
20
Endress+Hauser
Cerabar S
Devices with M12 plug
Cerabar S
+ –
–
+
M12
+ –
P01-PMx7xxxx-04-xx-xx-xx-000
Left: electrical connection for devices with M12 plug
Right: view of the plug at the device
Endress+Hauser offers for devices with M12 plug the following accessories:
Plug-in jack M 12x1, straight
• Material: Body PA; coupling nut CuZn, nickel-plated
• Degree of protection (fully locked): IP67
• Order number: 52006263
Plug-in jack M 12x1, elbowed
• Material: Body PBT/PA; coupling nut GD-Zn, nickel-plated
• Degree of protection (fully locked): IP67
• Order number: 51006327
Cable 4x0.34 mm2 with M12 socket, elbowed, screw plug, 5 m length
• Material: Body PUR; coupling nut CuSn/Ni; cable PVC
• Degree of protection (fully locked): IP67
• Order number: 52010285
Devices with 7/8" plug
Cerabar S
–
+ –
7/8"
+
+ –
P01-PMx7xxxx-04-xx-xx-xx-003
Left: electrical connection for devices with 7/8" plug
Right: view of the plug at the device
Endress+Hauser
21
Cerabar S
Taking 4...20 mA test signal
A 4...20 mA signal may be measured via the positive and test terminal without interrupting the measurement.
The minimum supply voltage of the device can be reduced by simply changing the position of the jumper. As
a result, operation is also possible with lower voltage sources. Observe the position of the jumper in accordance
with the following table.
Jumper position for test signal
Test
Test
Supply voltage
Description
– Taking 4...20 mA test signal via plus and test terminal:
possible. (Thus, the output current can be measured without
interruption via the diode.)
– Delivery status
– minimum supply voltage: 11.5 V DC
– Taking 4...20 mA test signal via plus and test terminal:
not possible.
– minimum supply voltage: 10.5 V DC
Note!
• When using the measuring device in hazardous areas, installation must comply with the corresponding
national standards and regulations and the Safety Instructions or Installation or Control Drawings.
• All explosion protection data are given in separate documentation which is available upon request. The Ex
documentation is supplied as standard with all devices approved for use in explosion hazardous areas. → See
also page 91 ff sections "Safety Instructions" and "Installation/Control Drawings".
4...20 mA HART
• Version for non-hazardous areas, jumper for 4...20 mA test signal in "Test" position (delivery status):
11.5...45 V DC
• Version for non-hazardous areas, jumper for 4...20 mA test signal in "Non-test" position: 10.5...45 V DC
PROFIBUS PA
• Version for non-hazardous areas: 9...32 V DC
FOUNDATION Fieldbus
• Version for non-hazardous areas: 9...32 V DC
Current consumption
• PROFIBUS PA: 11 mA ± 1 mA, switch-on current corresponds to IEC 61158-2, Clause 21
• FOUNDATION Fieldbus: 14 mA ± 1 mA, switch-on current corresponds to IEC 61158-2, Clause 21
Cable entry
→ See also page 77 ff, feature 30 "Housing, Cable entry, Protection".
Cable specification
• Endress+Hauser recommends using shielded, twisted-pair two-wire cables.
• Terminals for wire cross-sections 0.5...2.5 mm2
• Cable external diameter: 5...9 mm
Residual ripple
Without influence on 4...20 mA signal up to ± 5% residual ripple within the permitted voltage range [according
to HART hardware specification HCF_SPEC-54 (DIN IEC 60381-1)]
Influence of power supply
≤ 0.0006% of URL/1 V
22
Endress+Hauser
Cerabar S
Performance characteristics – general
Reference operating
conditions
•
•
•
•
•
•
•
•
•
•
•
•
As per IEC 60770
Ambient temperature TU = constant, in the range of: +21...+33°C (+69.8...+91.4°F)
Humidity ϕ = constant, in the range of: 5...80 % r.H
Ambient pressure pU = constant, in the range of: 860...1060 mbar
Position of the measuring cell: constant, in the range of: ±1°
Input of LOW SENSOR TRIM and HIGH SENSOR TRIM for lower range value and upper range value
Zero based span
Membrane material PMC71: Al2O3 (Aluminium oxide ceramic)
Membrane material PMP71 and PMP75: AISI 316L/1.4435
Filling oil PMP71 and PMP75: silicone oil
Supply voltage: 24 V DC ± 3 V DC
Load with HART: 250 Ω
Uncertainty of measurement
for small absolute pressure
ranges
The smallest extended uncertainty of measurement that can be returned by our standards is:
• 0.4% of the set span in the range of 1...30 mbar and
• 1% of the set span in the range < 1 mbar.
Long-term stability
PMC71/PMP71/PMP75:
• For measuring ranges ≥ 1 bar: ± 0,05 % of URL/year
PMC71:
• 100 mbar ... 40 bar: ±0,2 % of URL/10 years
• 100 mbar ... 40 bar (absolute pressure sensor): ±0,3 % of URL/10 years
PMP71:
• 1 bar ... 10 bar: ±0,175 % of URL/5 years
• 40 bar: ±0,2 % of URL/5 years
• 40 bar: ±0,4 % of URL/10 years
• 100 bar: ±0,2 % of URL/10 years
• 400 bar: ±1 % of URL/10 years
Influence of the installation
position
• PMC71 1: ≤ 0.18 mbar
• PMP71 1, 2
– Process connections thread G 1 A, G 1 1/2, G 2, 1 1/2 MNPT, 2 MNPT, M 44x1.25, EN/DIN, ANSI
and JIS flanges: ≤ 10 mbar
– Process connections thread: G 1/2, 1/2 MNPT, JIS G 1/2, JIS R 1/2, M20x1.5: ≤ 4 mbar
1)
2)
Device rotated 180°, process connection pointing upwards.
This value is doubled for devices with inert oil.
Position-dependent zero shift can be corrected. → See also page 29, section "General installation instructions"
and page 73 ff section "Installation instructions, Diaphragm seal systems".
Endress+Hauser
23
Cerabar S
Performance characteristics – ceramic diaphragm
Reference accuracy – PMC71
The reference accuracy comprises the non-linearity according to limit point setting, hysteresis and
non-reproducibility as per IEC 60770.
PMC71 – Gauge pressure sensors
100 mbar measuring cell:
• TD 1:1: to TD 10:1 ±0.075% of the set span
• TD > 10:1: ±0.0075% of the set span x TD
250 mbar, 400 mbar, 1bar, 2 bar, 4 bar, 10 bar measuring cell:
• TD 1:1: to TD 15:1 ±0.075% of the set span
• TD > 15:1: ±0.005% of the set span x TD
40 bar measuring cell:
• TD 1:1 to TD 10:1: ±0.075% of the set span
• TD > 10:1: ±0.0075% of the set span x TD
Platinum version,
1 bar, 2 bar, 4 bar, 10 bar measuring cell:
• TD 1:1: ±0.05% of the set span
PMC71 – Absolute pressure sensors
100 mbar measuring cell:
• TD 1:1: to TD 5:1: ±0.075% of the set span
• TD > 5:1: ±0.015% of the set span x TD
250 mbar measuring cell:
• TD 1:1: to TD 10:1: ±0.075% of the set span
• TD > 10:1: ±0.0075% of the set span x TD
400 mbar, 1 bar, 2 bar, 4 bar, 10 bar measuring cell:
• TD 1:1: to TD 15:1: ±0.075% of the set span
• TD > 15:1: ±0.005% of the set span x TD
40 bar measuring cell:
• TD 1:1 to TD 10:1: ±0.075% of the set span
• TD > 10:1: ±0.0075% of the set span x TD
Platinum version,
1 bar, 2 bar, 4 bar, 10 bar measuring cell:
• TD 1:1: ±0.05% of the set span
Total performance – PMC71
The "Total performance" specification comprises the non-linearity including hysteresis, non-reproducibility as
well as the thermal change of the zero point.
All specifications apply to the temperature range –10...+60°C (+14...+140°F).
PMC71
100 mbar, 250 mbar, 400 mbar measuring cell:
• ±0.2% of URL
1 bar, 2 bar, 4 bar, 10 bar, 40 bar measuring cell:
• ±0.15 % of URL
PMC71 High temperature version
all measuring cells:
• ±0.46% of URL
Total Error - PMC71
The total error comprises the long-term stability and the total performance:
PMC71:
• 100 mbar, 250 mbar, 400 mbar measuring cell: ±0,25 % of URL/year
• 1 bar, 2 bar, 4 bar, 10 bar, 40 bar measuring cell: ±0,2 % of URL/year
PMC71 High temperature version:
• all measuring cells: ±0,51 % of URL/year
24
Endress+Hauser
Cerabar S
Warm-up period – PMC71
• 4...20 mA HART : < 10 s
• PROFIBUS PA: 6 s
• FOUNDATION Fieldbus: 50 s
Thermal change of the zero
output and the output span –
PMC71
PMC71
–10...+60°C (+14...+140 °F):
• 100 mbar, 250 mbar, 400 mbar measuring cell: ±(0.088 x TD + 0.088)% of the set span
• 1 bar, 2 bar, 4 bar, 10 bar, 40 bar measuring cell: ±(0.088 x TD + 0.04)% of the set span
–20...–10°C, +60...+125°C (–4...+14°F, +140...+257°F)
• 100 mbar, 250 mbar, 400 mbar, measuring cell: ±(0.138 x TD + 0.138)% of the set span
• 1 bar, 2 bar, 4 bar, 10 bar, 40 bar measuring cell: ±(0.175 x TD + 0.075)% of the set span
PMC71 High temperature version
–10...+60°C (+14...+140 °F):
• 100 mbar, 250 mbar, 400 mbar measuring cell: ±(0.088 x TD + 0.088)% of the set span
• 1 bar, 2 bar, 4 bar, 10 bar, 40 bar measuring cell: ±(0.088 x TD + 0.04)% of the set span
–20...–10°C, +60...+150°C (–4...+14°F, +140...+302°F):
• 1 bar, 2 bar, 4 bar, 10 bar, 40 bar measuring cell:: ±(0,50 x TD)% of the set span
• 100 mbar measuring cell (Absolute pressure sensor): ±(1,25 x TD)% of the set span
• 250 mbar, 400 mbar, 1 bar, 2 bar, 4 bar, 10 bar measuring cell (Absolute pressure sensor):
±(0,75)% of the set span
• 40 bar measuring cell (Absolute pressure sensor): ±(0,50)% of the set span
Endress+Hauser
25
Cerabar S
Performance characteristics – metallic diaphragm
Reference accuracy –
PMP71, PMP75
The reference accuracy comprises the non-linearity according to limit point setting, hysteresis and
non-reproducibility as per IEC 60770.
PMP71 and PMP75 without capillary
100 mbar, 400 mbar measuring cell:
• TD 1:1: to TD 2:1 ±0.15% of the set span
250 mbar measuring cell:
• TD 1:1: to TD 2.5:1 ±0.15% of the set span
400 mbar measuring cell:
• TD 1:1: ±0.15% of the set span
• TD > 1:1: ±0.15% of the set span x TD
1 bar measuring cell:
• TD 1:1 to TD 2.5:1: ±0.075% of the set span
• TD > 2.5:1: ±0.03% of the set span x TD
2 bar measuring cell:
• TD 1:1 to TD 5:1: ±0.075% of the set span
• TD > 5:1: ±0.015% of the set span x TD
4 bar measuring cell:
• TD 1:1 to TD 10:1: ±0.075% of the set span
• TD > 10:1: ±0.0075% of the set span x TD
10 bar, 40 bar measuring cell:
• TD 1:1 to TD 15:1: ±0.075% of the set span
• TD > 15:1: ±0.005% of the set span x TD
100 bar measuring cell:
• TD 1:1 to TD 10:1: ±0.075% of the set span
• TD > 10:1: ±0.0075% of the set span x TD
400 bar measuring cell:
• TD 1:1 to TD 5:1: ±0.15% of the set span
• TD > 5:1: ±0.03% of the set span x TD
700 bar measuring cell:
• TD 1:1 to TD 2:1: ±0.2% of the set span
• TD > 2:1: ±0.1% of the set span x TD
Platinum version,
2 bar, 4bar, 10 bar, 40 bar measuring cell:
• TD 1:1: ±0.05% of the set span
PMP75 with capillary
1 and 2 bar measuring cell:
• TD 1:1 to TD 2,5:1: ±0,1% of the set span
• TD > 2,5:1: ±0,04% of the set span x TD
1 bar measuring cell (Absolute pressure sensor):
• TD 1:1 to TD 2,5:1: ±0,1% of the set span
• TD > 2,5:1: ±0,04% of the set span x TD
2 bar measuring cell (Absolute pressure sensor):
• TD 1:1 to TD 5:1: ±0,075% of the set span
• TD > 5:1: ±0,015% of the set span x TD
26
Endress+Hauser
Cerabar S
Total performance – PMP71
The "Total performance" specification comprises the non-linearity including hysteresis, non-reproducibility as
well as the thermal change of the zero point.
All specifications apply to the temperature range –10...+60°C (+14...+140°F).
PMP71
100 mbar measuring cell:
• ±0.35% of URL
250 mbar measuring cell:
• ±0.3% of URL
400 mbar measuring cell:
• ±0.25% of URL
1 bar, 2 bar, 4 bar, 10 bar, 40 bar measuring cell:
• ±0.15% of URL
100 bar measuring cell:
• ±0.25% of URL
400 bar measuring cell:
• ±0.3% of URL
700 bar measuring cell:
• ±0.4% of URL
PMP71 with Gold-Rhodium-coated membrane
400 mbar measuring cell:
• ±1.25% of URL
1 bar measuring cell:
• ±0.75% of URL
2 bar measuring cell:
• ±0.45% of URL
4 bar measuring cell:
• ±0.3% of URL
10 bar and 40 bar measuring cell:
• ±0.15% of URL
100 bar measuring cell:
• ±0.25% of URL
400 bar measuring cell:
• ±0.3% of URL
700 bar measuring cell:
• ±0.4% of URL
Total Error - PMP71
The total error comprises the long-term stability and the total performance:
•
•
•
•
•
•
•
Warm-up period –
PMP71, PMP75
Endress+Hauser
100 mbar measuring cell: ±0,4 % of URL/year
250 mbar measuring cell: ±0,35 % of URL/year
400 mbar measuring cell: ±0,3 % of URL/year
1 bar, 2 bar, 4 bar, 10 bar, 40 bar measuring cell: ±0,2 % of URL/year
100 bar measuring cell: ±0,3 % of URL/year
400 bar measuring cell: ±0,35 % of URL/year
700 bar measuring cell: ±0,45 % of URL/year
• 4...20 mA HART : < 10 s
• PROFIBUS PA: 6 s
• FOUNDATION Fieldbus: 50 s
27
Cerabar S
Thermal change of the zero
output and the output span –
PMP71 and PMP75
!
28
PMP71 and PMP75 (basic device)
–10...+60°C (+14...+140°F):
• 100 mbar measuring cell: ±(0.3 x TD + 0.02)% of the set span
• 250 mbar measuring cell: ±(0.25 x TD + 0.02)% of the set span
• 400 mbar measuring cell: ±(0.2 x TD + 0.015)% of the set span
• 1 bar, 2 bar, 4 bar, 10 bar, 40 bar measuring cell: ±(0.1 x TD + 0.01)% of the set span
• 100 bar measuring cell: ±(0.2 x TD + 0.015)% of the set span
• 400 bar measuring cell: ±(0.35 x TD + 0.02)% of the set span
• 700 bar measuring cell: ±(0.4 x TD + 0.03)% of the set span
–40...–10°C, +60...+85°C (–40...+14°F, +140...+185°F):
• 100 mbar measuring cell: ±(0.6 x TD + 0.04)% of the set span
• 250 mbar measuring cell: ±(0.5 x TD + 0.04)% of the set span
• 400 mbar measuring cell: ±(0.4 x TD + 0.03)% of the set span
• 1 bar, 2 bar, 4 bar, 10 bar, 40 bar measuring cell: ±(0.4 x TD + 0.02)% of the set span
• 100 bar measuring cell: ±(0.4 x TD + 0.03)% of the set span
• 400 bar measuring cell: ±(0.7 x TD + 0.04)% of the set span
• 700 bar measuring cell: ±(0.75 x TD + 0.06)% of the set span
Note!
When using a PMP75, the influence from the respective diaphragm seal must be taken into account.
(→ See also page 68 ff "Planning instructions, diaphragm seal systems" and page 52 ff "Process connections
PMP75 (with metallic measuring diaphragm)").
Endress+Hauser
Cerabar S
Operating conditions (installation)
General installation
instructions
• For PMP75: See page 52 ff, "Installation instructions, Diaphragm seal systems" section.
• The position-dependent zero shift can be corrected directly at the device via operating key, for devices with
external operation even in hazardous areas. Diaphragm seals also shift the zero point, depending on the
installation position.
(→ See also page 73 ff, section "Installation instructions, Diaphragm seal systems").
• The housing of the Cerabar S can be rotated up to 380°. → See also page 31, section "Turn the housing".
• Endress+Hauser offers a mounting bracket for installing on pipes or walls. → See also page 30, section "Wall
and pipe-mounting".
Installation instructions for
devices without diaphragm
seal – PMC71 and PMP71
Cerabar S transmitters without diaphragm seal are mounted as per the norms for a manometer (DIN EN 8392). We recommend the use of shut-off devices and siphons. The orientation depends on the measuring
application.
Pressure measurement in gases
• Mount Cerabar S with shut-off device above the tapping point so that condensate can flow into the process.
Pressure measurement in steams
• Mount Cerabar S with siphon above the tapping point.
The siphon reduces the temperature to almost ambient temperature.
• Fill the siphon with fluid before commissioning.
Pressure measurement in liquids
• Mount Cerabar S with shut-off device below or at the same level as the tapping point.
Level measurement
• Mount Cerabar S below the lowest measuring point.
• Do not mount the device at the following positions:
In the fill flow, in the tank outlet or at a point in the container which could be affected by pressure pulses
from an agitator or a pump.
• The calibration and functional test can be carried out more easily if you mount the device after a shut-off
device.
Heat insulation –
PMC71 high temperature
version and PMP75
The PMC71 high temperature version and the PMP75 must only be insulated up to a certain height. The
maximum permitted insulation height is labelled on the devices and applies to an insulation material with a
heat conductivity ≤ 0.04 W/(m x K) and to the maximum permitted ambient and process temperature (→ see
table below). The data were determined under the most critical application "quiescent air".
λ ≤ 0.04 W
m•K
TA
TP
P01-PMx7xxxx-11-xx-xx-xx-010
Maximum insulation height, here e.g. PMC71 with flange
Endress+Hauser
PMC71 high temperature version
PMP75
Ambient temperature (TA)
≤ 70°C (158°F)
≤ 70°C (158°F)
Process temperature (TP)
≤ 150°C (302°F)
max. 350°C (662°F), depending on the
diaphragm seal filling oil used (→ see
page 69)
29
Cerabar S
Mounting with temperature
isolator
Endress+Hauser recommends the use of temperature isolators in the event of constant extreme fluid
temperatures which lead to the maximum permissible ambient temperature of +85°C (+185°F) being
exceeded.
Depending on the filling oil used, Cerabar S devices with temperature isolators can be used for maximum
temperatures of up to 260°C (+500°F). → For the temperature application limits of filling oils, see page 69,
"Diaphragm seal filling oil" section.
To minimise the influence of rising heat, Endress+Hauser recommends the device be mounted horizontally or
with the housing pointing downwards.
The additional installation height also brings about a zero point shift of maximum 21 mbar due to the
hydrostatic columns in the temperature isolator. The position-dependent zero shift can be corrected.
max. 115
P01-PMx7xxxx-11-xx-xx-xx-005
PMP75 with temperature isolator
Endress+Hauser offers a mounting bracket for installing the device on pipes or walls. → See also page 77 ff,
feature 110, "Additional options 2".
101
118
Wall and pipe-mounting
70
P01-PMx7xxxx-06-xx-xx-xx-001
30
Endress+Hauser
Cerabar S
"Separate housing" version
With the "separate housing" version, you are able to mount the housing with the electronics insert at a distance
from the measuring point. This facilitates zero-interference measurement:
• Under particularly difficult measuring conditions (at installation locations that are cramped or difficult to
access)
• If rapid cleaning of the measuring point is required
• If the measuring point is exposed to vibrations.
IP 69K applies for the process connection with sensor if FEP cable are used.
You can choose between different cable versions:
• PE (2 m, 5 m and 10 m)
• FEP (5 m).
→ See also Page 84 ff, Feature 110, "Additional options 2", Version "G".
→ For the dimensions, see Page 65.
➃
➂
➀
r ³ 120 mm
➁
P01-PMx7xxxx-11-xx-xx-xx-012
In the case of the "separate housing" version, the sensor is delivered with the process connection and cable ready
mounted. The housing and a mounting bracket are enclosed as separate units. The cable is provided with a socket at both
ends. These sockets are simply connected to the housing and the sensor.
1
2
3
4
Process connection with sensor
Cable, both ends are fitted with a socket
Mounting bracket provided, suitable for pipe and wall mounting
Housing with electronic insert
Technical data of the PE and FEP cable:
• Minimum bending radius: 120 mm (4.72 inch)
• Cable extraction force: max. 450 N
• Resistance to UV light
Turn the housing
The housing can be rotated up to 380° after loosening the Allen screw.
Your benefits
• Simple mounting by optimally aligning the housing
• Good, accessible device operation
• Optimum readability of the on-site display (optional).
Endress+Hauser
31
Cerabar S
FIELD TERMINALS
max. 380°
P01-PMx7xxxx-17-xx-xx-xx-000
Align the housing by loosening the Allen screw.
T14 housing: 2 mm Allen key; T17 housing: 3 mm Allen key
Oxygen applications
Oxygen and other gases can react explosively to oils, grease and plastics, such that, among other things, the
following precautions must be taken:
– All components of the system, such as measuring devices, must be cleaned in accordance with the BAM
(DIN 19247) requirements.
– Dependent on the materials used, a certain maximum temperature and a maximum pressure for oxygen
applications must not be exceeded.
The devices suitable for gaseous oxygen applications are listed in the following table with the specification pmax.
Order code for devices cleaned for
oxygen applications
pmax for oxygen applications
Tmax for oxygen
applications
PMC71 – * * * ** * ** 2 * *,
Devices with sensors,
nominal value < 10 bar
Overpressure limit (OPL) of sensor1, 2
60°C (140°F)
PMC71 – * * * ** * ** 2 * *,
Devices with sensors,
nominal value ≥ 10 bar
30 bar
60°C (140°F)
PMP71 – * * * ** * * ** N * *
Depends on the weakest link in terms of
pressure of the selected components: over
pressure limit (OPL) of sensor1 or process
connection (1.5 x PN) or filling fluid
(160 bar)
85°C (185°F)
PMP75 – * * * ** * * * ** N * *
Depends on the weakest link in terms of
pressure of the selected components: over
pressure limit (OPL) of sensor1 or process
connection (1.5 x PN) or filling fluid
(160 bar)
85°C (185°F)
1)
→ See page 77 ff "Ordering information", feature 40 "Sensor range; sensor overload limit (= OPL)"
2)
PMC71 with PVDF thread or flange pmax = 15 bar (225 psi)
LABS-free applications
Cleaning of the transmitter for the use e.g. in paint shops.
Ultra pure gas applications
Endress+Hauser also offers the degreased device for special applications, such as ultra pure gas.
No special restrictions regarding the process conditions apply to this device.
→ See also page 79, "Ordering information PMC71", feature 80 "Seal" or page 83, "Ordering information
PMP71", feature 90 "Fill fluid".
Diaphragm seals for materials
with hydrogen build-up (GoldRhodium coating)
With regard to materials in which hydrogen build-up takes place, hydrogen atoms can diffuse through the metal
diaphragms. This can result in incorrect measurement results.
Endress+Hauser offers diaphragms with Gold-Rhodium coating for this application.
→ See also page 82 "Ordering information PMP71" and page 86 "Ordering information PMP75", feature 60
"Membrane material" version "6".
32
Endress+Hauser
Cerabar S
Operating conditions (environment)
Ambient temperature limits
!
• PMC71:
– –40...+85°C (–40...+185°F)
– High temperature version: –20...+70°C (–4...+158°F)
(Version "T" for feature 100 "Additional options 1" or feature 110 "Additional options 2"),
→ For the maximum insulation height see page 30.
• PMP71: –40...+85°C (–40...+185°F)
devices for lower temperatures on request
• PMP75: –40...+85°C (–40...+185°F)
devices for lower temperatures on request
→ For the maximum insulation height see page 30.
• On-site display: –20...+70°C (–4...+158°F)
Extended temperature application range with restrictions in optical properties such as display speed and
contrast: –40...+85°C (–40...+185°F)
• Separate housing: –40 to +60°C (–40 to +140°F)
Note!
For high-temperature applications, either a PMP75 with a temperature isolator or with a capillary can be used.
If vibrations also occur in the application, Endress+Hauser recommends you use a PMP75 with a capillary. If
a PMP75 with a temperature isolator or capillary is used, we recommend a suitable retaining unit for mounting
(see "Wall and pipe-mounting" Section on page 30).
For devices for use in hazardous areas, see Safety instructions, Installation or Control Drawing. (→ See also
page 91, sections "Safety Instructions" and "Installation/Control Drawings".)
The device can be used in this temperature range. The values of the specification, such as thermal change, may
be exceeded. → See also DIN 16086.
Storage temperature range
• –40...+100°C (–40...+212°F)
• On-site display: –40...+85°C (–40...+185°F)
• Separate housing: –40 to +60°C (–40 to +140°F)
Degree of protection
• → See page 77 ff, feature 30 "Housing, Cable entry, Protection".
• Degree of protection IP 68 for T17 housing: 1.83 mH2O for 24 h
• Degree of protection IP 69K for process connection with sensor with separate housing and FEP cable.
Climate class
Class 4K4H (air temperature: –20...55°C/–4...+131°F, relative humidity: 4...100%) fulfilled as per
DIN EN 60721-3-4 (condensation possible)
1)
Vibration resistance
With PMC71, avoid condensate in the device (avoid moisture collecting in the device).
Device/Additional option
PMC71
1
Test standard
Vibration resistance
GL
guaranteed for
3...25 Hz: ±16 mm;
25...100 Hz: 4 g
in all 3 planes
IEC 61298-3
guaranteed for
10...60 Hz: ±0.15 mm;
60...500 Hz: 2 g
in all 3 planes
PMP71
PMP75 2, 3
with mounting bracket
Endress+Hauser
1)
not for high temperature version with EEx d[ia], CSA XP or FM XP
2)
with aluminium T14 housing only
3)
For applications with high temperatures, either a PMP75 with a temperature isolator or with a capillary can be used.
If vibrations also occur in the application, Endress+Hauser recommends using a PMP75 with a capillary. If a PMP75
with a temperature isolator or capillary is used, it must be mounted with a mounting bracket. (→ see also page 30).
33
Cerabar S
Electromagnetic compatibility
• Electromagnetic compatibility to EN 61326 and NAMUR recommendation EMC (NE21). For details refer
to the declaration of conformity.
• With enhanced immunity against electromagnetic fields as per EN 61000-4-3:
30 V/m with closed cover 1
• Maximum deviation: < 0.5% of span
• All EMC measurements were performed with a turn down (TD) = 2:1.
1)
Overvoltage protection
for devices with T14 housing
• Overvoltage protection:
– Nominal functioning DC voltage: 600 V
– Nominal discharge current: 10 kA
• Surge current check î = 20 kA as per DIN EN 60079-14: 8/20 μs satisfied
• Arrester AC current check I = 10 A satisfied
→ See also page 80 ff, feature 100 "Additional options 1" and feature 110 "Additional options 2", version "M
Overvoltage protection".
Note!
Devices with integrated overvoltage protection must be earthed.
34
Endress+Hauser
Cerabar S
Operating conditions (Process)
Process temperature limits
PMC71 (with ceramic measuring diaphragm)
• –25...+125°C (–13...+257°F)
• High temperature version: –20...+150°C (–4...+302°F)
→ See also page 80, feature 100 "Additional options 1", Version "T".
• Observe the process temperature range of the seal. See also the following section "Process temperature range,
seals".
Extreme jumps in temperature can result in temporary measuring errors. Temperature compensation takes effect after several
minutes. Internal temperature compensation is faster the smaller the temperature jump and the longer the time interval.
PMP71 (with metallic measuring diaphragm)
Description
Temperature operating range
Process connections with internal diaphragm
–40...+125°C (–40...+257°F)
(+150 °C/302°F for max. one hour)
Process connections with flush-mounted diaphragm,
G 1 A, G 1 1/2 A, G 2 A, 1 NPT, 1 1/2 NPT, 2 NPT,
M 44 x 1.25, EN/DIN, ANSI and JIS flanges
–40...+100°C (–40...+212°F)
Process connections with flush-mounted diaphragm, G 1/2 A, M 20 –20...+85°C (–4...+185°F)
Lower temperatures on request.
PMP75 (with metallic measuring diaphragm)
• depending on the diaphragm seal and filling oil from -70°C (-94°F) up to +400°C (+752°F). Observe the
temperature application limits of the diaphragm seal oil. → See also page 69, section "Diaphragm seal filling
oils".
!
Process temperature range,
seals
Note!
• Do not use diaphragm seals with 0.09 mm PTFE foil on AISI 316L (1.4435/1.4405) for vacuum
applications, upper temperature limit +204°C (+400°F).
• For oxygen applications, observe page 32, section "Oxygen applications".
PMC71 (with ceramic measuring diaphragm)
Version for feature 80
in the order code
Seal
Process temperature range
A, L
FKM Viton
–25...+125°C/150°C 1 (–4...+257°F/302°F)
B 2, 3
EPDM (FDA 21CFR177.2600; 3A Class II;
USP Class VI) DVGW (KTW, W270,
W534), WRAS, ACS, NSF61
–20...+125°C/150 °C (–4...+257°F/302°F)
B3
EPDM
–20...+125°C (–4...+257°F)
D, M
Kalrez, Compound 4079
+5...+125°C/150°C 1 (+41...+257°F/302°F)
E
Chemraz, Compound 505
–10...+125°C/150°C 1 (14...+257°F/302°F)
F 2, 4
HNBR (FDA 21CFR177.2600; 3A Class II;
KTW; AFNOR; BAM)
–25...+125°C (–4...+257°F)
F4
NBR
–10...+100°C (14...+212°F)
1
FKM Viton, cleaned from oil and greace
–10...+125°C (+14...+257°F)
2
FKM Viton, cleaned for oxygen service
–10...+60 °C (+14...+140°F)
1
The process temperature ranges specified here refer to permanent application of the PMC71. They may be exceeded for a
short time (e.g. for cleaning).
Endress+Hauser
1)
+150°C (+302°F): for high temperature version
→ See also page 80, feature 100 "Additional options 1" and feature 110 "Additional options 2", Version "T".
2)
These seals are used for devices with 3A-approved process connections.
35
Cerabar S
Pressure specifications
3)
With applications of saturated steam a Cerabar S with metallic diaphragm seal is to be used.
4)
For devices with NBR or HNBR seals, the values for "Toatal Performance" (→ see page 24) and "Thermal change"
(→ see page 25) must be multiplied by the factor 3.
• The maximum pressure for the measuring device is dependent on the lowest-rated element with regard to
pressure, see the following sections for this:
– → page 13 ff, section "Measuring range"
– → chapter "Mechanical construction".
The MWP (maximum working pressure) is specified on the nameplate. This value refers to a reference
temperature of 20°C (68°F) or 100°F for ANSI flanges and may be applied to the device for an unlimited
time. Observe temperature dependency.
• The pressure values permitted at higher temperatures can be found in the following standards:
– EN 1092-1: 2001 Tab. 18 1
– ASME B 16.5a – 1998 Tab. 2-2.2 F316
– ASME B 16.5a – 1998 Tab. 2.3.8 N10276
– JIS B 2220.
• The test pressure corresponds to the over pressure limit of the measuring instrument (Over Pressure Limits
OPL = 1.5 x MWP 2) and may fit only temporally limited, so that no permanent damage develops.
• The Pressure Equipment Directive (EC Directive 97/23/EC) uses the abbreviation "PS". The abbreviation
"PS" corresponds to the MWP (maximum working pressure) of the measuring device.
• In the case of sensor range and process connections where the OPL (Over pressure limit) of the pressure
connection is smaller than the nominal value of the sensor, the device is set at the factory, at the very
maximum, to the OPL value of the process connection. If you want to use the entire sensor range, select a
process connection with a higher OPL value (1.5 x PN; PN = MWP).
• In oxygen applications, the values for "pmax and Tmax for oxygen applications" as per page 32, "Oxygen
applications" may not be exceeded.
1)
2)
36
With regard to its stability property, the material 1.4435 is identical to 1.4404 which is grouped under 13EO
in EN 1092-1 Tab. 18. The chemical composition of the two materials can be identical.
The equation does not apply for PMP71 and PMP75 with a 40 bar or 100 bar measuring cell.
Endress+Hauser
Cerabar S
Mechanical construction
Housing dimensions T14
152
111
FIELD TERMINALS
H
111
P01-PMx7xxx-06-00-xx-xx-000
Front view, left-hand side view, top view
→ See the process connection in question for installation height. Housing weight see page 66.
132
152
102
111
115
111
FIELD TERMINALS
HH
Housing dimensions T17
P01-PMx7xxxx-06-00-xx-xx-001
Front view, left-hand side view, top view
→ See the process connection in question for installation height. Housing weight see page 66.
Endress+Hauser
37
Cerabar S
Process connections PMC71
(with ceramic measuring
diaphragm)
Note!
Some device versions have CRN approval. For a CRN-approved device, a CRN-approved process connection
(→ see page 79, feature 70 "Process connection") has to be ordered with a CSA approval (→ see page 77,
feature 10 "Approval"). These devices are fitted with a separate plate bearing the registration number
0F10525.5C.
Thread, internal diaphragm
G 1/2A 11.4 mm
17
20
H
3
ø3
ø6
G 1/2
17
20
13
17
20
ø8
➂
G 1/2A G 1/4
H
➁
G 1/2A
H
➀
G 1/4
ø17.5
G 1/2
ø11.4
ø17.5
G 1/2
P01-PMC71xxx-06-09-xx-xx-001
Process connections PMC71, thread ISO 228
→ Installation height see page 39.
25
ø11.4
1/4 NPT
1/2 NPT
ø11.4
1/2 NPT
➂ 1/2 MNPT
3 mm
➃ 1/2 FNPT
H
11.4 mm
25
➁ 1/2 MNPT
H
1/4 FNPT
H
➀ 1/2 MNPT
25
3
H
2
Thread ISO 228 G 1/2 A EN 837;
Material version GA: AISI 316L/1.4435, version GB: Alloy C276/2.4819, version GC: Monel,
Version GD: PVDF (max.: 15 bar/225 psi, max.: –10...+60°C/+14...+140°F); mount version "GD" with a mounting
bracket only (→ see also page 30); Weight: 0,63 kg
Thread ISO 228 G 1/2 A G 1/4 (female);
Material version GE: AISI 316L/1.4435, version GF: Alloy C276/2.4819, version GG: Monel; Weight: 0,63 kg
Thread ISO 228 G 1/2 A hole 11.4 mm;
Material version GH: AISI 316L/1.4435, version GJ: Alloy C276/2.4819, version GK: Monel; Weight: 0,63 kg
25
1
ø3
1/2 NPT
1/2 NPT
ø26.5
P01-PMC71xxx-06-09-xx-xx-002
Process connections PMC71, thread ANSI
→ Installation height see page 39.
1
2
3
4
38
Thread ANSI 1/2 MNPT 1/4 FNPT;
Material version RA: AISI 316L/1.4435, version RB: Alloy C276/2.4819, version RC: Monel; Weight: 0,63 kg
Thread ANSI 1/2 MNPT hole 11.4;
Material version RD: AISI 316L/1.4435, version RE: Alloy C276/2.4819, version RF: Monel; Weight: 0,63 kg
Thread ANSI 1/2 MNPT hole 3 mm;
Material version RG: PVDF(max.: 15 bar/225 psi, max.: –10...+60°C/+14...+140°F),
mount with mounting bracket only (→ see also page 30); Weight: 0,63 kg
Thread ANSI 1/2 FNPT;
Material version RH: AISI 316L/1.4435, version RJ: Alloy C276/2.4819, version RK: Monel; Weight: 0,63 kg
Endress+Hauser
Cerabar S
➁
R 1/2
H
G 1/2
3
ø3
ø5
23
20
ø8
13.2
H
➀
ø11.4
R 1/2
G 1/2
P01-PMC71xxx-06-09-xx-xx-003
Process connections PMC71, thread JIS
→ Installation height see page 39.
1
2
Version GL: thread JIS B0202 G 1/2 (male), material: AISI 316L/1.4435; Weight: 0,63 kg
Version RL: thread JIS B0203 R 1/2 (male), material: AISI 316L/1.4435; Weight: 0,63 kg
H
M20x1.5
17
20
ø8
3
ø3
ø6
M20x1.5
P01-PMC71xxx-06-09-xx-xx-004
Process connections PMC71 thread DIN 13 M 20x1.5 hole 3 mm
Material version GP: AISI 316L/1.4435, version GQ: Alloy C276/2.4819
→ Installation height see page 39; Weight: 0,63 kg.
Installation height H for devices with thread connection and internal diaphragm
Description
Housing T14
Housing T17
PMC71
155 mm
171 mm
PMC71 with EEx d[ia], CSA XP or FM XP
225 mm
241 mm (Ex d = 311 mm)
PMC71 High temperature version 1
235 mm
251 mm
PMC 71 High temperature version 1 with
EEx d[ia], CSA XP or FM XP
305 mm
321 mm (Ex d = 391 mm)
1)
Endress+Hauser
High temperature version, see also page 80, feature 100 "Additional options 1" and
feature 110 "Additional options 2", versions "T"
39
Cerabar S
Thread, flush-mounted diaphragm
➀ G 1 1/2
➁
G2
30
25
28
G 1 1/2
ø55
33.5
H
SW 60
60 AF
H
SW 60
60 AF
G2
ø68
H
11
30
2 NPT
ø68
SW 60
60 AF
H
SW 60
60 AF
27
H
SW 60
60 AF
1 1/2 NPT
➄ M44x1.25
2 NPT
22
➃
33.5
➂ 1 1/2 NPT
ø40.5
M44x1.25
P01-PMC71xxx-06-09-xx-xx-005
Process connections PMC71,
→ Installation height see table below.
1
2
3
4
5
Thread ISO 228 G 1 1/2 A;
Material version 1G: AISI 316L/1.4435, version 1H: Alloy C276/2.4819, version 1J: Monel; Weight: 0,63 kg
Thread ISO 228 G 2 A;
Material version 1K: AISI 316L/1.4435, version 1L: Alloy C276/2.4819, version 1M: Monel; Weight: 0,63 kg
Thread ANSI 1 1/2 MNPT;
Material version 2D: AISI 316L/1.4435, version 2E: Alloy C276/2.4819, version 2F: Monel; Weight: 0,63 kg
Thread ANSI 2 MNPT;
Material version 2G: AISI 316L/1.4435, version 2H: Alloy C276/2.4819, version 2J: Monel; Weight: 0,63 kg
Thread DIN 13 M 44x1.25;
Material version 1R: AISI 316L/1.4435, version 1S: Alloy C276/2.4819; Weight: 0,63 kg
Installation height H for devices with thread connection and flush-mounted diaphragm
40
Description
Housing T14
Housing T17
PMC71
215 mm
231 mm
PMC71 with EEx d[ia], CSA XP or FM XP
280 mm
296 mm
Endress+Hauser
Cerabar S
EN/DIN flanges, connection dimensions as per EN 1092-1/DIN 2527
b
2
H
g2
g
k
D
P01-PMC71xxx-06-09-xx-xx-006
Process connection PMC71, EN/DIN flange with raised face (flush-mounted diaphragm)
→ Installation height see page 43.
Flange
Version
Material
Boltholes
Nominal
diameter
Nominal
pressure
Shape
1
Diameter
Thickness
Raised
face
D
b
[mm]
Quantity
Diameter
Hole
circle
Flange
weight 2
g
g2
k
[mm]
[mm]
[mm]
[mm]
[kg]
CP
AISI 316L
DN 32
PN 10-40
B1 (D)
140
18
77
4
18
100
1.9
CQ
AISI 316L
DN 40
PN 10-40
B1 (D)
150
18
87
4
18
110
2.2
DN 50
PN 10-16
B1 (D)
165
21.4
102
4
18
125
0.6
3
BR
PVDF
B3
AISI 316L
DN 50
PN 10-40
B1 (D)
165
20
102
4
18
125
3.0
C3
AISI 316L
DN 50
PN 63
B2 (D)
180
26
108
4
22
135
4.6
DN 80
PN 10/16
B1 (D)
200
21.4
138
8
18
160
1.0
DN 80
PN 10-40
B1 (D)
200
24
138
8
18
160
5.4
3
BS
PVDF
B4
AISI 316L
1)
Designation in brackets as per DIN 2527
2)
Housing weight see page 66
3)
Max.: 15 bar (225 psi), max.: –10...+60°C (+14...+140°F)
Endress+Hauser
41
Cerabar S
b
0.06
1.6
g2
H
ANSI flange, connection dimensions as per ANSI B 16.5, raised face RF
g
k
D
P01-PMC71xxx-06-09-xx-xx-007
Process connection PMC71, ANSI flange with raised face (flush-mounted diaphragm)
→ Installation height see page 43.
Flange
Version
Material
Boltholes
Nominal
diameter
Class
Diameter
Thickness
Raised face Quantity
Diameter
Hole circle
D
b
g
g2
k
[in]
[mm]
[in]
[mm]
[kg]
[in]
[lb./sq.in]
[in]
[mm]
[in]
[mm]
[in]
[mm]
Flange
weight 1
AE
AISI 316/
316L 2
1 1/2
150
5
127
0.69
17.5
2.88
73.2
4
0.62
15.7
3.88
98.6
1.0
AQ
AISI 316/
316L 2
1 1/2
300
6.12
155.4
0.81
20.6
2.88
73.2
4
0.88
22.4
4.5
114.3
2.6
AF
AISI 316/
316L 2
2
150
6
152.4
0.75
19.1
3.62
91.9
4
0.75
19.1
4.75
120.7
2.4
JR
ECTFE 3
2
150
6
152.4
0.75
19.1
3.62
91.9
4
0.75
19.1
4.75
120.7
2.4
A3
PVDF 4
2
150
6
152.4
0.75
19.1
3.62
91.9
4
0.75
19.1
4.75
120.7
0.5
AR
AISI 316/
316L 2
2
300
6.5
165.1
0.88
22.4
3.62
91.9
8
0.75
19.1
5
127
3.2
AG
AISI 316/
316L 2
3
150
7.5
190.5
0.94
23.9
5
127
4
0.75
19.1
6
152.4
4.9
JS
ECTFE 3
3
150
7.5
190.5
0.94
23.9
5
127
4
0.75
19.1
6
152.4
4.9
A4
PVDF 4
3
150
7.5
190.5
0.94
23.9
5
127
4
0.75
19.1
6
152.4
0.9
AS
AISI 316/
316L 2
3
300
8.25
209.5
1.12
28.4
5
127
8
0.88
22.4
6.62
168.1
6.8
AH
AISI 316/
316L 2
4
150
9
228.6
0.94
23.9
6.19
157.2
8
0.75
19.1
7.5
190.5
7.1
JT
ECTFE 3
4
150
9
228.6
0.94
23.9
6.19
157.2
8
0.75
19.1
7.5
190.5
7.1
AT
AISI 316/
316L 2
4
300
10
254
1.25
31.8
6.19
157.2
8
0.88
22.4
7.88
200.2
11.6
1)
Housing weight see page 66
2)
Combination of AISI 316 for required pressure resistance and AISI 316L for required chemical resistance (dual rated)
3)
ECTFE coating on AISI 316L/1.4435
When operating in hazardous area, avoid electrostatic charge of the plastic surface.
4)
max.: 15 bar (225 psi), max.: –10...+60°C (+14...+140°F)
42
Endress+Hauser
Cerabar S
JIS flange, connection dimensions as per JIS B 2220, raised face RF
H
b
2
g2
g
k
D
P01-PMC71xxx-06-09-xx-xx-008
Process connection PMC71, JIS flange with raised face RF (flush-mounted diaphragm), AISI 316L/1.4435
→ Installation height see table below.
Flange
Versions
Nominal
dimension
Boltholes
Nominal
pressure
Diameter
Thickness
Raised face
D
b
[mm]
Quantity
Diameter
Hole circle
Flange
weight 1
g
g2
k
[mm]
[mm]
[mm]
[mm]
[kg]
KF
50 A
10 K
155
16
96
4
19
120
2.0
KL
80 A
10 K
185
18
127
8
19
150
3.3
KH
100 A
10 K
210
18
151
8
19
175
4.4
1)
Housing weight see page 66
Installation height H for devices with flange
Endress+Hauser
Description
T14 housing
T17 housing
PMC71
215 mm
231 mm
PMC71 with EEx d[ia], CSA XP or FM XP
280 mm
296 mm
43
Cerabar S
Hygienic connections, flush-mounted diaphragm
Note!
Many process connections with an EPDM or HNBR seal are in accordance with the 3A-sanitary standard
approved for PMC71. This means that a 3A-approved process connection in combination with an EPDM or
HNBR seal must be selected when ordering for the 3A approval for the PMC71 version to be valid. → For
ordering information on EPDM or HNBR seals, see page 79 "Ordering information PMC71", feature 80 "Sensor
seal", version B or F.
➀
DIN 11851 DN 40
DIN 11851 DN 50
22
21
10
11
H
H
➁
ø48
Rd 65 x 1/6
➃ Clamp
ISO 2852 DN 76.1 (3")
H
Clamp ISO 2852 DN 51 (2")/
DIN 32676 DN 50
H
➂
ø61
Rd 78 x 1/6
83.5
ø91
ø56.5
ø64
➄
➅
DRD 65 mm
Varivent N DN 40 – DN 162
16
H
H
4 x ø11.5
ø68
ø84
ø65
ø84
ø105
P01-PMC71xxx-06-09-xx-xx-011
Process connections PMC71, Hygienic connections, material AISI 316L/1.4435
surface roughness of the surfaces in contact with the medium ≤ 0.8 μm as standard. Lower surface roughness on request.
1
2
3
4
5
6
Version MP: DIN 11851 DN 40 PN 25, 3A with HNBR or EPDM seal
Version MR: DIN 11851 DN 50 PN 25, 3A with HNBR or EPDM seal
Version TD: Tri-Clamp ISO 2852 (2"), DIN 32675 DN 50, 3A with HNBR or EPDM seal
Version TF: Tri-Clamp ISO 2852 (3"), 3A with HNBR or EPDM seal
Version TK: DRD DN50 (65 mm) PN 25, 3A with HNBR or EPDM seal
Version TR: Varivent Type N for pipes 40 – 162, PN 40, 3A with HNBR or EPDM seal
Installation height H for devices with hygienic connection and flush-mounted diaphragm
44
Description
T14 housing
T17 housing
PMC71
215 mm
231 mm
PMC71 with EEx d[ia], CSA XP or FM XP
280 mm
296 mm
Endress+Hauser
Cerabar S
Process connections PMP71
(with metallic measuring
diaphragm)
Note!
Some device versions have CRN approval. For a CRN-approved device, a CRN-approved process connection
(→ see page 78, feature 70 "Process connection") has to be ordered with a CSA approval (→ see page 77,
feature 10 "Approval"). These devices are fitted with a separate plate bearing the registration number
0F10525.5C.
Thread, internal diaphragm
➂ G 1/2A
H
17
13
17
20
20
ø11.4
ø17.5
G 1/4
3
3
ø11.4
ø3.2
ø6
11.4
H
G 1/4
G 1/2 A
ø17.5
ø17.5
20
➁ G 1/2A
G 1/2A
H
➀
G 1/2 A
G 1/2 A
P01-PMP71xxx-06-09-xx-xx-000
Process connections PMP71, thread ISO 228
→ Installation height H see page 46.
➂ 1/2 FNPT
H
7
ø11.4
ø21.4
11.4
H
➁ 1/2 MNPT
25
15
ø21.4
1/4 NPT
1/2 NPT
ø11.4
1/2 NPT
20
1/4 FNPT
H
➀ 1/2 MNPT
10
3
8
2
Thread ISO 228 G 1/2 A EN 837;
Material version GA: AISI 316L/1.4435, version GB: Alloy C276/2.4819; Weight: 0,6 kg
Thread ISO 228 G 1/2 A G 1/4 (female);
Material version GE: AISI 316L/1.4435, version GF: Alloy C276/2.4819; Weight: 0,6 kg
Thread ISO 228 G 1/2 A hole 11.4 mm;
Material version GH: AISI 316L/1.4435, version GJ: Alloy C276/2.4819; Weight: 0,6 kg
25
1
1/2 NPT
ø38
P01-PMP71xxx-06-09-xx-xx-001
Process connections PMP71, thread ANSI
→ Installation height see page 46.
1
2
3
Endress+Hauser
Thread ANSI 1/2 MNPT 1/4 FNPT;
Material version RA: AISI 316L/1.4435, version RB: Alloy C276/2.4819; Weight: 0,6 kg
Thread ANSI 1/2 MNPT hole 11.4;
Material version RD: AISI 316L/1.4435, version RE: Alloy C276/2.4819; Weight: 0,6 kg
Thread ANSI 1/2 FNPT;
Material version RH: AISI 316L/1.4435, version RJ: Alloy C276/2.4819; Weight: 0,7 kg
45
Cerabar S
➁ R 1/2
H
H
➀ G 1/2
ø8
23
23
3
ø21.4
ø3
ø5
ø11.4
R 1/2
G 1/2
P01-PMP71xxx-06-09-xx-xx-002
Process connections PMP71, thread JIS
→ Installation height H see table, below.
1
2
Version GL: thread JIS B0202 G 1/2 (male), material: AISI 316L/1.4435; Weight: 0,6 kg
Version RL: thread JIS B0203 R 1/2 (male), material: AISI 316L/1.4435; Weight: 0,6 kg
H
M 20x1.5
17
20
ø11.4
ø17.5
M20x1.5
P01-PMP71xxx-06-09-xx-xx-003
Process connections PMP71 thread DIN 13 M 20x1.5 hole 11.4 mm
Material version GP: AISI 316L/1.4435, version GQ: Alloy C276/2.4819; Weight: 0,6 kg
→ Installation height H see table, below.
Installation height H for devices with thread connection and internal flush-mounted diaphragm
Height H
T14 housing
T17 housing
165 mm
181 mm
Note!
The versions with 700 bar sensor are approx. 20 mm (0.79 inch) higher.
46
Endress+Hauser
Cerabar S
Thread, flush-mounted diaphragm
➁ G 1A
G 1/2A
➂ G 1 1/2A
➃ G 2A
dM = ø28
ø30
G 1A
ø36
ø39
G 1/2A
ø23.6
ø26.5
1
26 8
2
2
2
2
dM = ø17.5
31
H
3
18
ø30
14
3
3.5
H
3.5
ø18.4
H
H
➀
dM = ø28
dM = ø28
ø56.3
G2A
ø68
ø36
G 1 1/2A
ø55
P01-PMP71xxx-06-09-xx-xx-004
Process connections PMP71, thread ISO 228
→ Installation height see page 48.
1
2
3
4
Thread ISO 228 G 1/2 A DIN 3852;
Material version 1A: AISI 316L/1.4435, version 1B: Alloy C276/2.4819; Weight: 0,4 kg
Thread ISO 228 G 1 A;
Material version 1D: AISI 316L/1.4435, version 1E: Alloy C276/2.4819; Weight: 0,7 kg
Thread ISO 228 G 1 1/2 A
Material version 1G: AISI 316L/1.4435, version 1H: Alloy C276/2.4819; Weight: 1,1 kg
Thread ISO 228 G 2 A
Material version 1K: AISI 316L/1.4435, version 1L: Alloy C276/2.4819; Weight: 1,5 kg
➁ 1 1/2 MNPT
➂ 2 MNPT
dM = ø28
1 NPT
33.5
23
27
H
H
H
➀ 1 MNPT
dM = ø28
1 1/2 NPT
dM = ø28
2 NPT
P=1-PMP71xxx-06-09-xx-xx-005
Process connections PMP71, thread ANSI
→ Installation height see page 48.
1
2
3
Endress+Hauser
Thread ANSI 1 MNPT;
Material version 2A: AISI 316L/1.4435, version 2B: Alloy C276/2.4819; Weight: 0,7 kg
Thread ANSI 1 1/2 MNPT;
Material version 2D: AISI 316L/1.4435, version 2E: Alloy C276/2.4819; Weight: 1,0 kg
Thread ANSI 2 MNPT
Material version 2G: AISI 316L/1.4435, version 2H: Alloy C276/2.4819; Weight: 1,3 kg
47
Cerabar S
➁ M 44x1.25
23
8
H
2
dM = ø17.5
2
14
ø17.7
3
3.5
H
➀ M 20x1.5
dM = ø17.5
ø40.5
M20x1.5
ø23.6
ø26.5
M44x1.25
ø55
P01-PMP71xxx-06-09-xx-xx-006
Process connections PMP71, thread DIN
→ Installation height see table, below.
1
2
Thread DIN 16288 M20;
Material version 1N: AISI 316L/1.4435, version 1P: Alloy C276/2.4819; Weight: 0,4 kg
Thread DIN 13 M 44 x 1.25;
Material version 1R: AISI 316L/1.4435, version 1S: Alloy C276/2.4819; Weight: 1,1 kg
Installation height H for devices with thread connection and flush-mounted diaphragm
48
Description
Housing T14
Housing T17
G 1/2
163 mm
179 mm
G1
167 mm
183 mm
G 1 1/2 A
163 mm
179 mm
G2A
162 mm
178 mm
1 MNPT
162 mm
178 mm
1 1/2 MNPT
165 mm
181 mm
2 MNPT
159 mm
175 mm
M 20x1.5
163 mm
179 mm
M 44x1.25
170 mm
186 mm
Endress+Hauser
Cerabar S
b
2
g2
h
H
EN/DIN flanges, connection dimensions as per EN 1092-1/DIN 2527
dM = ø28
g
k
D
P01-PMP71xxx-06-09-xx-xx-008
Process connection PMP71, EN/DIN flange with raised face, material AISI 316L
H: device height = height of device without flange h + flange thickness b
→ Height h see page 51.
Flange
Version
Nominal
diameter
Boltholes
Nominal
pressure
Shape
1
Diameter
Thickness
Raised face
D
b
[mm]
Quantity
Diameter
Hole circle
Flange
weight 2
g
g2
k
[mm]
[mm]
[mm]
[mm]
[kg]
CN
DN 25
PN 10-40
B1 (D)
115
18
66 3
4
14
85
1.2
CP
DN 32
PN 10-40
B1 (D)
140
18
77 3
4
18
100
1.9
CQ
DN 40
PN 10-40
B1 (D)
150
18
87 3
4
18
110
2.2
B3
DN 50
PN 10-40
B1 (D)
165
20
102
4
18
125
3.0
B4
DN 80
PN 10-40
B1 (D)
200
24
138
8
18
160
5.3
1)
Designation as per DIN 2527 in brackets
2)
Housing weight see page 66
3)
With these process connections the sealing surface is smaller than described in the standard. To achieve sufficient sealing, a flat seal with a thickness < 2mm
has to be selected. For further information please contact your local Endress+Hauser Sales Center.
Endress+Hauser
49
Cerabar S
b
2
g2
h
H
ANSI flanges, connection dimensions as per ANSI B 16.5, raised face RF
JIS flanges, connection dimensions as per B 2220, Raised face RF
dM = ø28
g
k
D
P01-PMP71xxx-06-09-xx-xx-009
Process connection PMP71, ANSI flange or JIS flange with raised face RF; material
H: device height = height of device without flange h + flange thickness b. For the height h see page 51.
Flange
Version
Boltholes
Material
Nominal
diameter
Class/
Nominal
pressure
Diameter
Thickness Diameter
raised face
Height
raised
face
D
b
g
[in]
[mm]
[in]
[mm]
Quantity
Diameter
Hole
circle
Flange
weight 1
f
g2
k
[in]
[mm]
[in]
[mm]
[in]
[mm]
[in]
[mm]
[kg]
ANSI flange
AN
AISI 316/
316L2
1 in
300
lb./sq.in
4.88
124
0.69
17.5
23
50,8
0.06
1.6
4
0.75
19.1
3.5
88.9
1.3
AE
AISI 316/
316L 2
1 1/2 in
150
lb./sq.in
5
127
0.69
17.5
2,88 3
73,2
0.06
1.6
4
0.62
15.7
3.88
98.6
1.5
AQ
AISI 316/
316L 2
1 1/2 in
300
lb./sq.in
6.12
155.4
0.81
20.6
2.88 3
73,2
0.06
1.6
4
0.88
22.4
4.5
114.3
2.6
AF
AISI 316/
316L 2
2 in
150
lb./sq.in
6
152.4
0.75
19.1
3.62
91.9
0.06
1.6
4
0.75
19.1
4.75
120.7
2.4
AR
AISI 316/
316L 2
2 in
300
lb./sq.in
7.5
190.5
0.88
22.3
3.62
91.9
0.06
1.6
8
0.75
19.1
5
127
3.2
AG
AISI 316/
316L 2
3 in
150
lb./sq.in
7.5
190.5
0.94
23.9
5
127
0.06
1.6
4
0.75
19.1
6
152.4
4.9
AS
AISI 316/
316L 2
3 in
300
lb./sq.in
8.25
209.5
1.12
28.4
5
127
0.06
1.6
8
0.88
22.4
6.62
168.1
6.7
AH
AISI 316/
316L 2
4 in
150
lb./sq.in
9
228.6
0.94
23.9
6.19
157.2
0.06
1.6
8
0.75
19.1
7.5
190.5
7.1
AT
AISI 316/
316L 2
4 in
300
lb./sq.in
10
254
1.25
31.8
6.19
157.2
0.06
1.6
8
0.88
22.4
7.88
200.2
11.6
20 K
125
16
67
1
4
19
90
1.5
JIS flange
KA
KF
KL
KH
AISI 316L 4 25 A
AISI 316L
3
50 A
10 K
155
16
96
2
4
19
120
2.0
AISI 316L
3
80 A
10 K
185
18
127
2
8
19
150
3.3
AISI 316L
3
100 A
10 K
210
18
151
2
8
19
175
4.4
1)
Housing weight see page 66
2)
Combination of AISI 316 for required pressure resistance and AISI 316L for required chemical resistance (dual rated)
3)
With these process connections the sealing surface is smaller than described in the standard. To achieve sufficient sealing, a flat seal with a thickness < 2mm
has to be selected. For further information please contact your local Endress+Hauser Sales Center.
4)
AISI 316L/1.4435
50
Endress+Hauser
Cerabar S
Height h for devices with flange
Height h
T14 housing
T17 housing
165 mm
181 mm
75
H
78.5
1/4-18 NPT
7/16-20 UNF
63.5
Oval flange
P01-PMP71xxx-06-09-xx-xx-007
Version UR: oval flange adapter 1/4-18 NPT according to IEC 61518, mounting: 7/16-20 UNF; Weight: 1,9 kg
Prepared for diaphragm seal mount
h
➀ ➁ ➂
5
ø2.5
ø7.95
P01-PMP75xxx-06-09-xx-xx-xx-005
Version U1: prepared for diaphragm seal mount
1
2
3
Hole for filling fluid
Bearing
Threaded pin with an internal hexagon 4 mm
Height h
Endress+Hauser
T14 housing
T17 housing
190 mm
204 mm
51
Cerabar S
PMP75 Basic unit
h
➀
➁
P01-PMP75xxx-06-09-xx-xx-012
PMP75 Basic unit with diaphragm seal
1
2
PMP75 Basic unit
Diaphragm seal, here e.g. flange diaphragm seal
Height
Process connections PMP75
(with metallic measuring
diaphragm)
52
T14 housing
T17 housing
190 mm
204 mm
Note!
• Some device versions have CRN approval. For a CRN-approved device, a CRN-approved process connection
(→ see page 86, feature 70 "Process connection") has to be ordered with a CSA approval (→ see page 85,
feature 10 "Approval"). Devices with capillary are not CRN-approved. These devices are fitted with a
separate plate bearing the registration number 0F10525.5C.
• Specifications for the "TK Process" are listed in the following tables. These are typical values. The temperature
coefficients apply to silicone oil and the membrane material AISI 316L/1.4435. For other filling oils, this
temperature coefficient must be multiplied by the TK correction factor of the corresponding filling oil. For
the TK correction factors, see page 69, section "Diaphragm seal filling oils".
• With regard to the temperature coefficient "TK Ambient", devices with a temperature isolator behave like
devices with the same process connection with 0,1 m capillary.
• In addition, the temperature coefficient "TK Ambient" is listed in relation to the capillary length for the
diaphragm seal versions which can be supplied with capillaries as standard. This information is found on
page 69 ff, section "Influence of the temperature on the zero point".
• The weights of the diaphragm seals are given in the tables. See page 66 for the weight of the housing.
• The following drawings are drawings that illustrate how the system works in principle. In other words, the
dimensions of a diaphragm seal supplied can deviate from the dimensions given in this document.
Endress+Hauser
Cerabar S
Thread, flush-mounted diaphragm
SW
AF
x1
x1
h
h
SW
AF
dM
d1
dM
NPT
d2
G
d2
P01-PMP75xxx-06-09-xx-xx-003
Process connections PMP75, left: thread ISO 228, right: thread ANSI
Threaded connection
Ver- Material
sion
1
1D
AISI 316L
1E
Alloy C276
1G
AISI 316L
1H
Alloy C276
1K
AISI 316L
1L
Alloy C276
2A
AISI 316L
2B
Alloy C276
2D
AISI 316L
2E
Alloy C276
2G
AISI 316L
2H
Alloy C276
Diaphragm seal
Thread
G1A
Nominal
pressure
Diameter
Diameter
Screw-in
length
Across
flats
TK
TK
max. Dia- TK
Ambient Ambient Process
phragm
diameter ≤ 40 bar > 40 bar
Height
PN
d1
d2
x1
SW/AF
dM
h
[mm]
[mm]
[mm]
30
39
21 2
400
G 1 1/2 A
G2
400
44
400
1 MNPT
56
400
–
1 1/2 MNPT 400
2 MNPT
–
400
–
1)
AISI 316L/1.4435; Alloy C276/2.4819
2)
28 mm in conjucntion with high temperature oil
!
Endress+Hauser
55
68
48
52
78
30
30
28
30
30
[mm]
41
50
65
41
46
65
30
42
50
24
36
38
[mbar/10 K]
+16.03
+24.33
+4.70
–
–
–
+5.4
+8.18
+3.50
–
–
–
+1.76
+2.68
+1.60
–
–
–
+15.66
+24.42
+8.50
–
–
–
+8.14
+12.39
+3.90
–
–
–
+5.4
+8.18
+2.59
–
–
–
Diaphragm
seal
weight
[mm]
[kg]
19
0.4
0.5
20
0.9
1.0
20
1.9
2.1
37
0.6
0.7
20
0.9
1.0
35
1.8
2,0
Note!
With the use of high temperature oils the design can deviate strongly.
For further information please contact your local Endress+Hauser Sales Center.
53
Cerabar S
h
Tri-Clamp ISO 2852
dM
C7
P01-FMD78xxx-06-09-xx-xx-005
Process connection PMP75, material: AISI 316L/1.4435, surface roughness of the surfaces in contact with the medium
Ra ≤ 0.8 μm as standard. Lower surface roughness on request.
Version
TB
Nominal
diameter
ISO 2852
Nominal
diameter
DIN 32676
Nominal
diameter
Diameter
max.
Diaphragm
diameter
Height
TK
Ambient
≤ 40 bar
C7
dM
h
[in]
[mm]
[mm]
[mm]
[mbar/10 K]
TK
Ambient
> 40 bar
TK
Process
Diaphragm
seal weight
[kg]
DN 25
DN 25
1
50.5
24
37
+15.33
+24.0
+4.25
0.32
TC
1
DN 38
DN 40
1 1/2
50.5
34
30
+8.14
+12.39
+1.91
1.0
TD
1
DN 51
DN 50
2
64
48
30
+3.45
+4.81
+1.25
1.1
DN 76.1
–
3
91
73
30
+0.3
+0.35
+0.18
1.2
TF
1)
54
Diaphragm seal versions in conformity with ASME-BPE for use in biochemical processes, wetted surfaces Ra ≤ 0.4 μm (15.75 μin; 180 grit), electropolished;
to be ordered using feature 60 "Additional option", version "P" in the order code
Endress+Hauser
Cerabar S
d2
D
d1
h
Tri-Clamp pipe diaphragm seal ISO 2852
L
P01-FMD78xxx-06-09-xx-xx-001
Process connection PMP75, material AISI 316L, surface roughness of the surfaces in contact with the medium Ra ≤ 0.8
μm as standard. Lower surface roughness on request.
Version
SB
Nominal
diameter
ISO 2852
Nominal
diameter
Diameter
Diameter
Diameter
Height
Face-tofacelength
D
d1
d2
h
L
[in]
[mm]
[mm]
[mm]
[mm]
TK
Ambient
≤ 40 bar
TK
Ambient
> 40 bar
TK
Process
Diaphragm
seal
weight
[mbar/10 K]
[kg]
DN 25
1
22.5
43.5
50.5
67
126
+7.75
+8.69
+4.49
1.7
SC
1
DN 38
1 1/2
35.5
43.5
50.5
67
126
+5.17
+5.69
+3.46
1.0
SD
1
DN 51
2
48.6
56.5
64
79
100
+3.56
+3.91
+2.69
1.7
1)
Including 3.1 and pressure test as per Pressure Equipment Directive, category II
40
Varivent N for pipes DN 40 – DN 162
dM max. = 50
ø68
P01-FMD78xxx-06-09-xx-xx-006
Process connection PMP75, surface roughness of the surfaces in contact with the medium Ra ≤ 0.8 μm as standard. Lower
surface roughness on request.
Version
Material
Nominal
pressure
TK
Ambient
≤ 40 bar
TK
Ambient
> 40 bar
TK Process
[mbar/10 K]
TR 1
1)
Endress+Hauser
AISI 316L/
1.4435
PN 40
+2.26
+3.11
Diaphragm
seal weight
[kg]
+1.65
1.3
Diaphragm seal versions in conformity with ASME-BPE for use in biochemical processes, wetted surfaces
Ra ≤ 0.4 μm (15.75 μin; 180 grit), electropolished; to be ordered using feature 60 "Additional option", version "P" in
the order code
55
Cerabar S
23.6
41
DRD DN50 (65 mm)
dM max. =50
ø65–1.2
4 x ø11.5
ø84
ø105
P01-FM78xxx-06-09-xx-xx-002
Process connection PMP75, surface roughness of the surfaces in contact with the medium Ra ≤ 0.8 μm as standard. Lower
surface roughness on request.
Version
Material
Nominal
pressure
TK
Ambient
≤ 40 bar
TK
Ambient
> 40 bar
TK Process
Diaphragm
seal weight
[mbar/10 K]
TK
AISI 316L/
1.4435
PN 25
+2.26
[kg]
+3.11
+1.65
0,75
m
f
h
SMS nozzles with coupling nut
dM
G
D
P01-PMP75xxx-06-09-xx-xx-009
Process connection PMP75, material AISI 316L/1.4435, surface roughness of the surfaces in contact with the medium
Ra ≤ 0.8 μm as standard. Lower surface roughness on request.
Version Nominal
diameter
Nominal Diapressure meter
Adapter
height
Thread
Height
Height
max. dia- TK
phragm
Ambient
diameter ≤ 40 bar
D
f
G
m
h
dM
[mm]
[mm]
[mm]
TK
Ambient
> 40 bar
TK
Process
[inch]
[bar]
[mm]
[mm]
TG
1
PN 25
54
3,5
Rd 40 – 1/6
20
42.5
24
+15.66
+24.22
+7.25
0.25
TH
1 1/2
PN 25
74
4
Rd 60 – 1/6
25
57
36
+8.18
+12.39
+2.59
0.65
TI
2
PN 25
84
4
Rd 70 – 1/6
26
62
48
+5.4
+8.18
+1.10
1.05
56
[mbar/10 K]
Weight
diaphragm
seal
[kg]
Endress+Hauser
Cerabar S
f
m
h
APV-RJT nozzles with coupling nut
dM
G
D
P01-PMP75xxx-06-09-xx-xx-010
Process connection PMP75, material AISI 316L/1.4435, surface roughness of the surfaces in contact with the medium
Ra ≤ 0.8 μm as standard. Lower surface roughness on request.
Version
Nominal diameter
TK
Ambient
> 40 bar
TK
Process
Weight
diaphragm
seal
Nominal
pressure
Diameter
Adapter
height
Thread
Height
Height
max.
TK
diaphragm Ambient
≤ 40 bar
diameter
PN
D
f
G
m
h
dM
[inch]
[bar]
[mm]
[mm]
[mm]
[mm]
[mm]
TL
1
PN 40
77
6.5
1 13/16 – 1/8" 22
42.6
21
+15.66
+24.42
+4.21
0.45
TM
1 1/2
PN 40
72
6.4
2 5/16 – 1/8"
22
42.6
28
+8.18
+12.39
+2.59
0.75
TN
2
PN 40
86
6.4
2 7/8 – 1/8"
22
42.6
38
+5.4
+8.18
+1.76
1.2
[mbar/10 K]
[kg]
m
f
h
APV-ISS nozzles with coupling nut
SW/AF
dM
G
D
P01-PMP75xxx-06-09-xx-xx-011
Process connection PMP75, material AISI 316L/1.4435, surface roughness of the surfaces in contact with the medium
Ra ≤ 0.8 μm as standard. Lower surface roughness on request.
Version Nomi- Nominal dia- nal
meter pressure
Diameter
Adapter
height
Thread
Height Across
flat
Height max.
TK
diaphragm Ambient
≤ 40 bar
seal
D
f
G
m
h
dM
[mm]
[mm]
AF
TK
Process
[mbar/10 K]
Weight
Diaphragm
seal
[inch]
[bar]
[mm]
[mm]
TP
1
PN 40
54.1
4
1 1/2" – 1/8"
30
46.8
50
24
+15.66
+24.42
+4.21
0.4
TQ
1 1/2
PN 40
72
4
2" – 1/8"
30
62
50
34
+8.14
+12.39
+2.59
0.6
TS
2
PN 40
89
4
2 1/2" – 1/8"
30
77
50
45
+5.4
+8.18
+1.76
1.1
Endress+Hauser
[mm]
TK
Ambient
> 40 bar
[kg]
57
Cerabar S
f
m
k
40
Taper adapter with coupling nut, DIN 11851
dM
D
G
P01-FMD78xxx-06-09-xx-xx-007
Process connection PMP75, material AISI 316L/1.4435, surface roughness of the surfaces in contact with the medium
Ra ≤ 0.8 μm as standard. Lower surface roughness on request.
Taper adapter
Version
Nominal
diameter
Nominal
pressure
Slotted nut
Diaphragm seal
Diameter
Adapter
height
Thread
Height
Height
max. Dia- TK
Ambient
phragm
diameter ≤ 40 bar
D
f
G
k
m
dM
[mm]
[mm]
[mm]
[mm]
[mm]
TK
Ambient
> 40 bar
TK
Process
[mbar/10 K]
Diaphragm
seal
weight
[kg]
MR
DN 50
PN 25
68.5
11
Rd 78 x 1/6"
22
19
52
+2.21
+3.02
+1.40
1.1
MS
DN 65
PN 25
86
12
Rd 95 x 1/6"
35
21
66
+1.6
+2.1
+0.60
2.0
MT
DN 80
PN 25
100
12
Rd 110 x 1/4" 30
26
81
+0.66
+0.81
+0.40
2.55
h
Threaded adapter, DIN 11851
dM
d1
G
P01-FMD78xxx-06-09-xx-xx-008
Process connection PMP75, material AISI 316L/1.4435, surface roughness of the surfaces in contact with the medium
Ra ≤ 0.8 μm as standard. Lower surface roughness on request.
Threaded adapter
Version
Nominal
diameter
Nominal
pressure
Diaphragm seal
Diameter
Thread
Height
max.
Diaphragm
diameter
d1
G
h
dM
[mm]
[mm]
[mm]
TK
Ambient
≤ 40 bar
TK
Ambient
> 40 bar
TK Process
[mbar/10 K]
Diaphragm
seal weight
[kg]
M3
DN 50
PN 25
54
Rd 78 x 1/6"
35
52
+2.21
+3.02
+0.88
0.9
M4
DN 65
PN 25
71
Rd 95 x 1/6"
40
66
+1.6
+2.1
+0.60
1.7
M5
DN 80
PN 25
85
Rd 110 x 1/4" 40
81
+0.66
+0.81
+0.40
2.0
58
Endress+Hauser
Cerabar S
EN/DIN flanges, connection dimensions as per EN 1092-1/DIN 2527 and DIN 2501-1
b
40
g2
L
f
dM
g
k
dM
D
d3
g
P01-PMP75xxx-06-09-xx-xx-002
Process connection PMP75, EN/DIN flange with flush-mounted diaphragm, material AISI 316L
Flange
Version
Nominal
diameter
Nominal
pressure
Shape
1
Boltholes
Diaphragm seal
Quan- DiaHole
tity
meter circle
max.
Diaphragm
diameter
DiaThickmeter ness
Raised face
D
b
g
f
g2
k
dM
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
TK Ambient
≤ 40 bar
TK
Pro> 40 bar
cess
[mbar/10 K]
Diaphragm
seal
weight
[kg]
CN
DN 25
PN 10-40
B1 (D)
115
18
66
3
4
14
85
32
+16.03
+24.33
+3.20
2.1
DN
DN 25
PN 63-160
E
140
24
68
2
4
18
100
28
+16.03
+24.33
+3.20
2.5
EN
DN 25
PN 250
E
150
28
68
2
4
22
105
28
+16.03
+24.33
+5.17
3.7
E1
DN 25
PN 400
E
180
38
68
2
4
26
130
28
+16.03
+24.33
+5.17
7.0
CP
DN 32
PN 10-40
B1 (D)
140
18
77
2.6
4
18
100
34
+8.14
+12.39
+2.59
1.9
CQ
DN 40
PN 10-40
B1 (D)
150
18
87
2.6
4
18
110
48
+5.40
+8.18
+2.15
2.2
B3
DN 50
PN 10-40
B1 (D)
165
26
102
3
4
18
125
59
+2.21
+3.02
+1.50
3.0
C3
DN 50
PN 63
B2 (E)
180
26
102
3
4
22
135
59
+2.21
+3.02
+1.00
4.6
EF
DN 50
PN 100/
160
E
195
30
102
3
4
26
145
59
+2.21
+3.02
+1.00
6.2
ER
DN 50
PN 250
E
200
38
102
3
8
26
150
59
+2.21
+3.02
+1.15
7.7
E3
DN 50
PN 400
E
235
52
102
3
8
30
180
59
+2.21
+3.02
+1.15
14.7
B4
DN 80
PN 10-40
B1 (D)
200
24
138
3.5
8
18
160
89
+0.19
+0.25
+0.20
5.3
C4
DN 80
PN 100
B2 (E)
230
32
138
4
8
24
180
89
+0.19
+0.25
+0.35
8.9
C5
DN 100
PN 100
B2 (E)
265
36
175
5
8
30
210
89
+0.19
+0.25
+0.11
13.7
2
DN 50
PN 10-40
B1 (D)
165
20
102
3
4
18
125
47
+3.45
+4.81
+1.67
2
D4 2
DN 80
PN 10-40
B1 (D)
200
24
138
3.5
8
18
160
72
+0.19
+0.25
+0.70
2
D3
1)
Designation as per DIN 2527 in brackets
2)
50 mm, 100 mm or 200 mm extension selectable, for extension diameter and weight see the following table
Version
Endress+Hauser
Nominal
diameter
Nominal
pressure
Extension
length
Extension
diameter
Diaphragm seal
weight
[mm]
[mm] d3
[kg]
D3
DN 50
PN 10-40
50 / 100 / 200
48.3
3.2 / 3.8 / 4.4
D4
DN 80
PN 10-40
50 /100 / 200
76
6.2 / 6.7 / 7.8
59
Cerabar S
ANSI flanges B 16.5 RF
L
dM
400 – 2500 lb/sq.in
0.25 in (6.4 mm)
150, 300 lb/sq.in
0.06 in (1.6 mm)
b
40
g2
g
k
d3
D
g
P01-PMP75xxx-06-09-xx-xx-001
Process connection PMP75, ANSI flange B 16.5 RF with and without extended diaphragm seal
Flange
Version
Material
Boltholes
Nominal
diameter
Class
Diameter
Thickness
Raised
face
D
b
TK Ambient
TK
Pro> 40 bar
cess
Diameter
Hole
circle
max.
Diaphragm
diameter
g
g2
k
dM
[in]
[mm]
[in]
[mm]
[in]
[mm]
[mbar/10 K]
[in]
[lb./
sq.in]
[in]
[mm]
[in]
[mm]
[in]
[mm]
Quantity
Diaphragm seal
≤ 40 bar
Diaphragm
seal
weight
[kg]
AC
AISI 316/
316L 1
1
150
4.25
108
0.56
14.2
2
50.8
4
0.62
15.7
3.12
79.2
1.26
32
+16.03
+24.33
+3.65
1.2
AN
AISI 316/
316L 1
1
300
4.88
124
0.69
17.5
2
50.8
4
0.75
19.1
3.5
88.9
1.26
32
+16.03
+24.33
+3,65
1.3
HC
AISI 316/
316L 1
1
400/
600
4.88
124
0.69
17.5
2
50.8
4
0.75
19.1
3.5
88.9
1.26
32
+16.03
+24.33
+5.17
1.4
HN
AISI 316/
316L 1
1
900/
1500
5.88
149.4
1.12
28.4
2
50.8
4
1
25.4
4
101.6
1.26
32
+16.03
+24.33
+5.17
3.2
HO
AISI 316/
316L 1
1
2500
6.25
158.8
1.38
35.1
2
50.8
4
1
25.4
4.25
108
1.26
32
+16.03
+24.33
+5.17
4.6
AE
AISI 316/
316L 1
1 1/2
150
5
127
0.69
17.5
2.88
73.2
4
0.62
15.7
3.88
96.6
1.89
48
+8.14
+12.39
+1.90
1.5
AQ
AISI 316/
316L 1
1 1/2
300
6.12
155.4
0.81
20.6
2.88
73.2
4
0.88
22.4
4.5
114.3
1.89
48
+8.14
+12.39
+2.59
2.6
AF
AISI 316/
316L 1
2
150
6
152.4
0.75
19.1
3.62
91.9
4
0.75
19.1
4.75
120.7
2.32
59
+2.21
+3.02
+1.60
2.2
J3 2
AISI 316/
316L 1
2
150
6
152.4
0.75
19.1
3.62
91.9
4
0.75
19.1
4.75
120.7
1.85
47
+3.45
+4.81
+1.67
2
AR
AISI 316/
316L 1
2
300
6.5
165.1
0.88
22.4
3.62
91.9
8
0.75
19.1
5
127
2.32
59
+2.21
+3.02
+0.85
3.4
HF
AISI 316/
316L 1
2
400/
600
6.5
165.1
1
25.4
3.62
91.9
8
0.75
19.1
5
127
2.32
59
+2.21
+3.02
+0.85
4.3
HR
AISI 316/
316L 1
2
900/
1500
8.5
215.9
1.5
38.1
3.62
91.9
8
1
25.4
6.5
165.1
2.32
59
+2.21
+3.02
+0.75
10.3
H3
AISI 316/
316L 1
2
2500
9.25
235
2
50.8
3.62
91.9
8
1.12
28.4
6.75
171.5
2.32
59
+2.21
+3.02
+0.75
15.8
AG
AISI 316/
316L 1
3
150
7.5
190.5
0.94
23.9
5
127
4
0.75
19.1
6
152.4
3.50
89
+0.19
+0.25
+0.18
5.1
AS
AISI 316/
316L 1
3
300
8.25
209.5
1.12
28.4
5
127
8
0.75
19.1
6
152.4
3.5
89
+0.19
+0.25
+0.11
7.0
60
Endress+Hauser
Cerabar S
Flange
Version
Material
Boltholes
Nominal
diameter
Class
Diameter
Thickness
Raised
face
D
b
TK Ambient
TK
Pro≤ 40 bar > 40 bar cess
Diaphragm
seal
weight
[in]
[mm]
[mbar/10 K]
[kg]
Diameter
Hole
circle
max.
Diaphragm
diameter
g
g2
k
dM
[in]
[mm]
[in]
[mm]
[in]
[lb./
sq.in]
[in]
[mm]
[in]
[mm]
[in]
[mm]
Quantity
Diaphragm seal
J4 3
AISI 316/
316L 1
3
150
7.5
190.5
0.94
23.9
5
127
4
0.75
19.1
6
152.4
2.83
72
+0.19
+0.25
+0.70
2
J7 3
AISI 316/
316L 1
3
300
8.25
209.5
1.12
28.4
5
127
8
0.88
22.4
6.62
168.1
2.83
72
+0.19
+0.25
+0.70
2
AH
AISI 316/
316L 1
4
150
9
228.6
0.94
23.9
6.19
157.2
8
0.75
19.1
7.5
190.5
3.50
89
+0.19
+0.25
+0.33
7.2
AT
AISI 316/
316L 1
4
300
10
254
1.25
31.8
6.19
157.2
8
0.88
22.4
7.88
200.2
3.50
89
+0.19
+0.25
+0.11
11.7
J5 3
AISI 316/
316L 1
4
150
9
228.6
0.94
23.9
6.19
157.2
8
0.75
19.1
7.5
190.5
3.50
89
+0.19
+0.25
+0.11
2
J8 3
AISI 316/
316L 1
4
300
10
254
1.25
31.8
6.19
157.2
8
0.88
22.4
7.88
200.2
3.50
89
+0.19
+0.25
+0.11
2
1)
Combination of AISI 316 for required pressure resistance and AISI 316L for required chemical resistance (dual rated)
2)
2", 4", 6" or 8" extension selectable, for extension diameter and weight see the following table
Version
Endress+Hauser
Nominal
diameter
Class
Extension
length (L)
Extension
diameter
Diaphragm seal
weight
[in]
[lb./sq.in]
[in] [(mm)]
[in] [(mm)]
[kg]
J3
2
150
–
–
–
–
2 (50.8)
4 (101.6)
6 (152.4)
8 (203.2)
1.9 (48.3)
–
–
–
–
3.0
3.4
3.9
4.4
J4
3
150
–
–
–
–
2 (50.8)
4 (101.6)
6 (152.4)
8 (203.2)
2.99 (75.9)
–
–
–
–
6.0
6.6
7.1
7.8
J7
3
300
–
–
–
–
2 (50.8)
4 (101.6)
6 (152.4)
8 (203.2)
2.99 (75.9)
–
–
–
–
7.9
8.5
9.0
9.6
J5
4
150
–
–
–
–
2 (50.8)
4 (101.6)
6 (152.4)
8 (203.2)
3.7 (94)
–
–
–
–
8.6
9.9
11.2
12.4
J8
4
300
–
–
–
–
2 (50.8)
4 (101.6)
6 (152.4)
8 (203.2)
3.7 (94)
–
–
–
–
13.1
14.4
15.7
16.9
61
Cerabar S
b
f
40
JIS flange B 2220
dM
g
k
D
P01-PMP75xxx-06-09-xx-xx-000
Process connection PMP75, JIS flange, material AISI 316L
Flange
Version
Nominal
diameter
Boltholes
Nominal
pressure
Diaphragm seal
Diameter
Hole
circle
TK
max.
TK Ambient
Process
Diaphragm
≤ 40 bar > 40 bar
diameter
f
g2
k
dM
[mm]
[mm]
[mm]
[mm]
[mm]
[mbar/10 K]
Diameter
Thickness
Diameter
raised
face
Height
raised
face
D
b
g
[mm]
[mm]
Quantity
Diaphragm
seal
weight 1
[kg]
KC
25 A
10 K
125
14
67
1
4
19
90
32
+16.03
+24.33
+5.17
1.5
KF
50 A
10 K
155
16
96
2
4
19
120
59
+2.21
+3.02
+1.00
2.3
KL
80 A
10 K
185
18
127
2
8
19
150
89
+0.19
+0.25
+0.11
3.3
KH
100 A
10 K
210
18
151
2
8
19
175
89
+0.19
+0.25
+0.11
4.4
1)
62
Housing weight see page 66
Endress+Hauser
Cerabar S
Thread ISO 228 G 1/2 A and ANSI 1/2 MNPT, seperator
ø72.6
21.5
20
3
17
14
SW 30
AF 30
14
SW 30
AF 30
ø18.4
70
70
ø72.6
ø11.4
1/2 - 14 NPT
ø4
ø6
G 1/2A
P01-PMP75xxx-06-09-xx-xx-004
Process connection PMP75, versions "UA" and "UB", welded, material AISI 316L
ø115
92.5
84
ø115
17
SW 22
3
ø2.5
1/2 NPT
20
SW 36
19
SW 36
ø4
ø6
G 1/2A
P01-PMP75xxx-06-09-xx-xx-007
Process connection PMP75, versions "UC" and "UD", screwed, with integrated sealing lip, material AISI 316L
Version
Description
Nominal
pressure
TK Ambient
TK Process
[mbar/10 K]
!
Endress+Hauser
Diaphragm
seal weight
[kg]
UA
ISO 228 G 1/2 A
PN 160
+0.9
+0.30
1.43
UB
ANSI 1/2 MNPT
PN 160
+0.9
+0.30
1.43
UC
ISO 228 G 1/2 B
PN 400
+3.45
+1.28
4.75
DU
ANSI 1/2 MNPT
PN 400
+3.45
+1.28
4.75
Note!
With the use of high temperature oils the design can deviate strongly.
For further information please contact your local Endress+Hauser Sales Center.
63
Cerabar S
Thread 1/2 NPT und 1 NPT, seperator
ø118
15
1/2 NPT
SW 27
27 AF
ø30
27
44.5
26
19
12
94.5
76
ø118
1 NPT
SW 36
36 AF
ø52
P01-PMP75xxx-06-09-xx-xx-008
Process connection PMP75, versions "UG" and "UL", screwed, material AISI 316L , seal Viton
Version
Description
Nominal
pressure
TK Ambient
TK Process
[mbar/10 K]
64
Diaphragm seal
weight
[kg]
UG
1/2 NPT
PN 250
+3.45
+1.28
4.75
UH
1 NPT
PN 250
+3.45
+1.28
5.0
Endress+Hauser
Cerabar S
"Separate housing" version
101
118
45.5
131
84
ø51.7
P01-xxxxxxxx-06-xx-xx-xx-000
Dimensions T14 housing, optional display on the side. Housing weight see page 66.
101
76
45.5
147
118
ø51.7
P01-xxxxxxxx-06-xx-xx-xx-001
Dimensions T17 housing, optional display on the side. Housing weight see page 66.
r ³ 120 mm
r ³ 120 mm
T17
r ³ 120 mm
➀
➀
ø54.1
➀
71
55
55
T14
P01-xxxxxxxx-06-xx-xx-xx-002
Reduction of the mounting height of the process connection, for application of the separate housing.
1
Process connection adapter.
If the separate housing is used, the mounting height of the process connection is reduced by approx. 55 mm
as compared to the dimensions of the standard version.
The minimum bending radius (r) for the cable is 120 mm (4.7").
Endress+Hauser
65
Cerabar S
Weight
Housing
T14
T17
Aluminium
AISI 316L
AISI 316L
With electronic insert and on-site
display
1.2 kg
2.1 kg
1.2 kg
With electronic insert without on-site
display
1.1 kg
2.0 kg
1.1 kg
Separate housing
Weight of housing T14 or T17 + 0,5 kg.
Weight of sensor + 0,5 kg.
Process connections
• Process connections PMC71 (with ceramic measuring diaphragm): from page 38 ff
• Process connections PMP71 (with metallic measuring diaphragm): from page 45 ff
• Process connections PMP75 (with metallic measuring diaphragm): from page 52 ff
Material
T14 housing:
• T14 housing, selectable:
– Die-cast aluminium with protective powder-coating on polyester basis: RAL 5012 (blue),
cover: RAL 7035 (grey)
– Precision cast stainless steel AISI 316L (1.4435)
• External operation (keys and key covering): Polycarbonate PC-FR,
RAL 7035 (grey)
• Sight glass: Mineral glass
• Cable gland: Polyamid (PA)
• Pressure compensation filter: PA6 GF10
• Blind plug: PBT-GF30 FR, for Dust Ex, EEx d, FM XP and CSA XP: AISI 316L (1.4435)
• Seals:
– Cable and blind plug seal: Silicone (VMQ)
– Pressure compensation filter o-ring: Silicone (VMQ)
– Cover: EPDM
– Sight glass: Silicone (VMQ)
• Nameplates: AISI 304 (1.4301)
T17 housing:
• Housing: Stainless steel AISI 316L (1.4404)
• Sight glass:
– Version for non-hazardous area, ATEX EEx ia, NEPSI Zone 0/1 Ex ia, IECEx Zone 0/1 Ex ia, FM NI, FM
IS, CSA IS: Polycarbonate (PC)
– ATEX 1/2 D, ATEX 1/3 D, ATEX 1 GD, ATEX 1/2 GD, ATEX 3 G, FM DIP, CSA Dust Ex: Mineral glass
• Cable gland: Polyamid PA, for Dust-Ex: CuZn nickel-plated
• Blind plug: PBT-GF30 FR, for Dust-Ex: AISI 316L (1.4435)
• Pressure compensation filter: PA6 GF10
• Seals:
– Cable and blind plug seal: Silicone (VMQ)
– Pressure compensation filter o-ring: Silicone (VMQ)
– Cover: EPDM
– Sight glass: EPDM
• Nameplates: lasered
DIN/EN flanges
Endress+Hauser supplies DIN/EN flanges made of stainless steel AISI 316L with the material number 1.4435
or 1.4404. With regard to its stability property, the material 1.4435 is identical to 1.4404 which is grouped
under 13EO in EN 1092-1 Tab. 18. The chemical composition of the two materials can be identical.
Cable for separate housing:
• PE cable:
Slip-resistant cable with strain-relief members made of Dynemo; shielded using aluminium-coated film;
insulated with polyethylene (PE-LD), black; copper wires, twisted, UV resistant
• FEP cable:
Slip-resistant cable; shielded using galvanized steel wire netting; insulated with fluorinated ethylene
propylene (FEP), black; copper wires, twisted, UV resistant
66
Endress+Hauser
Cerabar S
Miscellaneous:
• Process diaphragm PMC71: Al2O3 Aluminium-oxide-ceramic (FDA 21CFR186.1256, USP Class VI),
ultrapure 99.9% (→ See also www.endress.com/ceraphire)
• Mounting accessories: Mounting kit with screws AISI 304 (1.4301)
• Capillary: AISI 316 Ti (1.4571)
• Protective hose for capillary: AISI 304 (1.4301)
• External earth terminal: AISI 304 (1.4301)
→ For process connections, process diaphragms, seals and filling oils see ordering information, page 77 ff.
Endress+Hauser
67
Cerabar S
Planning instructions, diaphragm seal systems
Applications
Diaphragm seal systems should be used if the process media and the device should be separated. Diaphragm
seal systems offer clear advantages in the following instances:
• In the case of high process temperatures (→ See also page 35, section "Process temperature limits".)
• For aggressive media
• If good and rapid measuring point cleaning is necessary
• If the measuring point is exposed to vibrations
• For mounting locations that are difficult to access
• For very humid mounting locations
Planning instructions
Diaphragm seals are separating equipment between the measuring system and the process medium.
A diaphragm seal system consists of:
• A diaphragm seal in a one-sided system
• Capillary tube
• Fill fluid and
• A pressure transmitter.
The process pressure acts via the diaphragm seal membrane on the liquid-filled system, which transfers the
process pressure via the capillary tube onto the sensor of the pressure transmitter.
Endress+Hauser delivers all diaphragm seal systems as welded versions. The system is hermetically sealed,
which ensures the highest reliability.
Note!
The correlations between the individual diaphragm seal components are presented in the following section.
For further information and comprehensive diaphragm seal system designs, please contact your local
Endress+Hauser Sales Center.
Diaphragm seal
The diaphragm seal determines the application range of the system by
• the diaphragm diameter
• the diaphragms: stiffness and material
• the design (oil volume).
Diaphragm diameter
The larger the diaphragm diameter (less stiffness), the smaller the temperature effect on the measurement
result.
Note: To keep the temperature effect in practice-oriented limits, you should select diaphragm seals with a
nominal diameter of ≥ DN 80, in as far as the process connection allows for it.
Diaphragm stiffness
The stiffness is dependent on the diaphragm diameter, the material, any available coating and on the diaphragm
thickness and shape. The diaphragm thickness and the shape are defined constructively. The stiffness of a
diaphragm seal membrane influences the temperature operating range and the measuring error caused by
temperature effects.
Capillary
Capillaries with an internal diameter of 1 mm are used as standard.
The capillary tube influences the TK zero point, the ambient temperature operating range and the response
time of a diaphragm seal system as a result of its length and internal diameter.
→ See also page 69 ff, sections "Influence of the temperature on the zero point" and "Ambient temperature
range".
→ Observe the installation instructions regarding capillary tubes. See page 73 ff, section "Installation
instructions".
68
Endress+Hauser
Cerabar S
Filling oil
When selecting the filling oil, fluid and ambient temperature as well as the operating pressure are of crucial
importance. Observe the temperatures and pressures during commissioning and cleaning. A further selection
criterion is the compatibility of the filling oil with the requirements of the process medium. For this reason,
only filling oils that are harmless to health are used in the food industry, such as vegetable oil or silicone oil
→ See also the following section "Diaphragm seal filling oils" section.
The filling oil used influences the TK zero point and the temperature operating range of a diaphragm seal system
and the response time. → See also page 69 ff, section "Influence of the temperature on the zero point".
Pressure transmitter
The pressure transmitter influences the temperature operating range, the TK zero point and the response time
as a result of its volume change. The volume change is the volume that has to be shifted to pass through the
complete measuring range.
Pressure transmitters from Endress+Hauser are optimised with regard to minimum volume change.
Diaphragm seal filling oils
Version 1
Filling oil
Permissible
Density
Permissible
temperature range 2 at temperature 2 range
0.05 bar ≤ pabs ≤ 1 bar at pabs ≥ 1 bar
Viscosity
Coefficient
of thermal
expansion
[g/cm3]
[cSt at
25°C
(77°F)]
[1/K]
TK
correction
factor
Note
A, H, 1 or 2 Silicone oil
–40...+180°C
(–40...+356°F)
–40...+250°C
(–40...+482°F)
0.96
100
0.00096
1
suitable for foods
FDA 21 CFR 175.105
G, 3 or 4
High
temperature oil
–10...+200°C
(+14...+392°F)
–10...+400°C
(+14...+752°F)
1.07
37
0.0007
0.72
high temperatures
F or N
Inert oil
–40...+80°C
(–40...+176°F)
–40...+175°C
(–40...+347°F)
1.87
27
0.000876
0.91
Oil for ultra pure gas
and oxygen
applications
D, 5 or 6
Vegetable oil
–10...+120°C
(+14...+248°F)
–10...+200°C
(+14...+392°F)
0.94
9.5
0.00101
1.05
suitable for foods
FDA 21 CFR 172.856
7 or 8
Low
temperature oil
–70...+80°C
–94...+176°F
–70...+180°C
–94...+356°F
0,92
4,4
–
–
low temperatures
1)
Version for feature 90 in the order code
2)
Observe temperature limits of the device (→ Page 33 and Page 35).
Influence of the temperature
on the zero point
A temperature change results in a volume change of the filling oil. The volume change is dependent on the
coefficient of thermal expansion of the filling oil and on the volume of the filling oil at calibration temperature
(constant in the range: +21 to +33°C (+69.8 to 91.4°F)). → See also page 48, "Filling oils, technical data"
section.
For example, the filling oil expands in the event of a temperature increase. The additional volume presses
against the diaphragm seal membrane. The stiffer a diaphragm is, the greater its return force, which counteracts
a volume change and acts on the measuring cell together with the operating pressure, thus shifting the zero
point. For the "TK Process" and "TK Ambient (for devices without capillary)", see page 52 ff, section "Process
connections PMP75".
The following diagrams display the temperature coefficient "TK Ambient" dependent on the capillary length.
The following application is displayed: capillary temperature and transmitter temperature (ambient
temperature) change, the process temperature corresponds to the calibration temperature.
The temperature coefficients obtained from the diagrams apply to silicone oil and the membrane material
AISI 316L/1.4435. For other filling oils, these temperature coefficients must be multiplied by the TK correction
factor of the corresponding filling oil. For the TK correction factors, see page 69,
section "Diaphragm seal filling oils".
With regard to the temperature coefficient "TK Ambient", devices with temperature isolator behave like devices
with the same process connection and 0,1 m capillary.
Endress+Hauser
69
Cerabar S
PN ≤ 40 bar
TK Ambient 16
[mbar/10 K]
7
14
6
12
5
10
8.4
mbar
10 K
8
4
6
7
4
3
2
2
1
0
0
1
2
3
4
5
6
7
8
9
10
Capillary length
[m]
P01-PMP75xxx-05-xx-xx-xx-007
Diagram TK Ambient dependent on the capillary length for PMP75, PN ≤ 40 bar
Example for:
– Diaphragm seal versions "B3, EN/DIN flange DN 50 PN 10-40 B1, AISI 316L"
– Capillary length: 5 m
– Ambient temperature, capillary/transmitter: 45°C
– Filling oil: silicone oil
1.
Select characteristic curve type for the diaphragm seal versions "B3" in accordance with the following
table.
Result: characteristic curve type 6
2.
Obtain value for TK Ambient from the diagram.
Result: 8.4 mbar/10 K
3.
TAmbient – TCalibration = 45°C – 25°C = 20°C ⇒ 8.4 mbar/10 K x 20 K = 16.8 mbar
Result: In this application, the zero point is shifted by 16.8 mbar.
Note!
• The influence of temperature on the zero point can be corrected with position calibration.
• The temperature influence can be minimised by using a filling oil with a smaller coefficient of thermal
expansion, shorter capillary, diaphragm seal with larger diaphragm diameter or by using a smaller capillary
internal diameter.
70
Endress+Hauser
Cerabar S
PN > 40 bar
7
TK Ambient 16
[mbar/10 K]
6
14
12
5
10
4
8
6
7
4
3
2
2
1
0
0
1
2
3
4
5
6
7
8
9
10
Capillary length
[m]
P01-PMP75xxx-05-xx-xx-xx-005
Diagram TK Ambient dependent on the capillary length for PMP75, PN > 40 bar
Characteristic
curve type
1
2
3
4
5
6
7
Endress+Hauser
Version
Diaphragm seal
B4
C4
C5
KL
KH
D4
AG
AS
AH
AT
J4
J7
J5
J8
TF
MT
M5
SD
SC
B3
C3
EF
ER
E3
AF
AR
HF
HR
H3
KF
MR
MS
M3
M4
TR
TK
EN/DIN flange DN 80 PN 10-40 B1, AISI 316L
EN/DIN flange DN 80 PN 100 B2, AISI 316L
EN/DIN flange DN 100 PN 100 B2, AISI 316L
JIS flange 10K 80A RF, AISI 316L
JIS flange 10K 100A RF, AISI 316L
EN/DIN flange DN 80, PN 10-40 B1, Extensions: 50 mm/100 mm/200 mm, AISI 316L
ANSI flange 3" 150 lbs RF, AISI 316/316L
ANSI flange 3" 300 lbs RF, AISI 316/316L
ANSI flange 4" 150 lbs RF, AISI 316/316L
ANSI flange 4" 300 lbs RF, AISI 316/316L
ANSI flange 3" 150 lbs RF, Extensions: 2"/4"/6"/8", AISI 316/316L
ANSI flange 3" 300 lbs RF, Extensions: 2"/4"/6"/8", AISI 316/316L
ANSI flange 4" 150 lbs RF, Extensions: 2"/4"/6"/8", AISI 316/316L
ANSI flange 4" 300 lbs RF, Extensions: 2"/4"/6"/8", AISI 316/316L
Tri-Clamp, ISO 2852 DN 76.1 (3"), AISI 316L/1.4435
DIN 11851 DN 80 PN 25, AISI 316L/1.4435
DIN 11851 DN 80 PN 25 socket, AISI 316L/1.4435
Pipe diaphragm seal Tri-Clamp, ISO 2852 DN 51 (2"), AISI 316L
Pipe diaphragm seal Tri-Clamp, ISO 2852 DN 38 (1 1/2"), AISI 316L
EN/DIN flange DN 50 PN 1040 B1, AISI 316L
EN/DIN flange DN 50 PN 63 B2, AISI 316L
EN/DIN flange DN 50 PN 100-160 E, AISI 316L
EN/DIN flange DN 50 PN 250 E, AISI 316L
EN/DIN flange DN 50 PN 400 E, AISI 316L
ANSI flange 2" 150 lbs RF, AISI 316/316L
ANSI flange 2" 300 lbs RF, AISI 316/316L
ANSI flange 2" 400/600 lbs RF, AISI 316/316L
ANSI flange 2" 900/1500 lbs RF, AISI 316/316L
ANSI flange 2" 2500 lbs RF, AISI 316/316L
JIS 10K 50A RF, AISI 316L
DIN 11851 DN 50 PN 25, AISI 316L/1.4435
DIN 11851 DN 65 PN 25, AISI 316L/1.4435
DIN 11851 DN 50 PN 25 socket, AISI 316L/1.4435
DIN 11851 DN 65 PN 25 socket, AISI 316L/1.4435
Varivent Type N for tubes DN 40 – DN 162, PN 40, AISI 316L/1.4435
DRD DN50 (65 mm), PN 25, AISI 316L/1.4435
71
Cerabar S
PN ≤ 40 bar
TK Ambient 160
[mbar/10 K]
140
13
120
12
100
80
11
60
10
40
9
20
8
0
0
1
2
3
4
5
6
7
8
9
10
Capillary length
[m]
P01-PMP75xxx-05-xx-xx-xx-008
Diagram TK Ambient dependent on the capillary length for PMP75, PN ≤ 40 bar
PN > 40 bar
TK Ambient 160
[mbar/10 K]
140
13
120
12
100
80
11
60
10
40
9
20
8
0
0
1
2
3
4
5
6
7
8
9
10
Capillary length
[m]
P01-PMP75xxx-05-xx-xx-xx-009
Diagram TK Ambient dependent on the capillary length for PMP75, PN > 40 bar
72
Endress+Hauser
Cerabar S
Characteristic
curve type
8
9
10
11
12
13
Version
Diaphragm seal
SB
D3
J3
TD
CQ
TI
TN
TS
CP
AE
AQ
TC
TH
TM
TS
CN
DN
EN
E1
AC
AN
HC
HN
HO
KC
TB
Pipe diaphragm seal Tri-Clamp, ISO 2852 DN 25 (1"), AISI 316L
EN/DIN flange PN10-40 B1, Extensions: 50 mm/100 mm/200 mm, AISI 316L
ANSI flange 2" 150 lbs, Extensions: 2"/4"/6"/8", AISI 316/316L
Tri-Clamp, ISO 2852 DN 51 (2"), AISI 316L/1.4435
EN/DIN flange DN 40 PN 10-40 B1, AISI 316L
SMS 2" PN 25, AISI 316L/1.4435
APV-RJT 2" PN 40, AISI 316L/1.4435
APV-ISS 2" PN 40, AISI 316L/1.4435
EN/DIN flange DN32 PN 10-40 B1, AISI 316L
ANSI flange 1 1/2" 150 lbs RF, AISI 316/316L
ANSI flange 1 1/2" 300 lbs RF, AISI 316/316L
Tri-Clamp, ISO 2852 DN 38 (1 1/2"), DIN 32676 DN 40, AISI 316L/1.4435
SMS 1 1/2" PN 25, AISI 316L/1.4435
APV-RJT 1 1/2" PN 40, AISI 316L/1.4435
APV-ISS 1 1/2" PN 40, AISI 316L/1.4435
EN/DIN flange PN 10-40 B1, AISI 316L
EN/DIN flange PN 64-160 E, AISI 316L
EN/DIN flange PN 250 E, AISI 316L
EN/DIN flange PN 400 E, AISI 316L
ANSI flange 1" 150 lbs RF, AISI 316/316L
ANSI flange 1" 300 lbs RF, AISI 316/316L
ANSI flange 1" 400/600 lbs RF, AISI 316/316L
ANSI flange 1" 900/1500 lbs RF, AISI 316/316L
ANSI flange 1" 2500 lbs RF, AISI 316/316L
JIS flange 10K 25 A RF, AISI 316L
Tri-Clamp, ISO 2852 DN 25 (1"), DIN 32676 DN 25, AISI 316L/1.4435
Ambient temperature range
The filling oil, capillary length, capillary internal diameter, process temperature and the oil volume of the
diaphragm seal determine the ambient temperature operating range of the diaphragm seal system.
The operating range can be extended by using a filling oil with a smaller coefficient of expansion and by using
shorter capillaries.
Installation instructions
Instructions for diaphragm seal systems
• The diaphragm seal together with the transmitter form a closed, calibrated system, which is filled through
ports in the diaphragm seal and in the measurement system of the transmitter. These ports are sealed and
must not be opened.
• In the case of devices with diaphragm seals and capillaries, the zero point shift caused by the hydrostatic
pressure of the filling liquid column in the capillaries must be taken into account when selecting the
measuring cell. If a measuring cell with a small measuring range is selected, a position adjustment can cause
an overdrive. See the following diagram and the following example.
• For devices with temperature isolator or capillary a suitable fastening device (mounting bracket) is
recommended.
• When using a mounting bracket, sufficient strain relief must be allowed for in order to prevent the capillary
bending down (bending radius ≥ 100 mm).
Installation instructions
In order to obtain more precise measurement results and to avoid a defect in the device, mount the capillaries
as follows:
• vibration-free (in order to avoid additional pressure fluctuations)
• not in the vicinity of heating or cooling lines
• insulate if the ambient temperature is below ore above the reference temperature
• with a bending radius of ≥ 100 mm.
Endress+Hauser
73
Cerabar S
Vacuum applications
For applications under vacuum, Endress+Hauser recommends mounting the pressure transmitter below the
diaphragm seal. A vacuum load of the diaphragm seal caused by the presence of fill fluid in the capillary
prevents is hereby prevented.
When the pressure transmitter is mounted above the diaphragm seal, the maximum height difference H1 in
accordance with the following illustration on the left must not be exceeded. The maximum height difference
is dependent on the density of the filling oil and the smallest ever pressure that is permitted to occur at the
diaphragm seal (empty tank), see the following illustration, on the right.
FIELD TERMINALS
12.0
H1
Height difference H1 [m]
Low temperature oil
10.0
Vegetable oil
8.0
Silicone oil
6.0
High temperature
oil
4.0
Inert oil
2.0
0.0
50 100 200
300
400
500
600
700
800
900 1000
Pressure at diaphragm seal [mbarabs]
P01-PMx7xxxx-11-xx-xx-xx-008
Installation above the diaphragm seal
74
P01-PMP75xxx-05-xx-xx-en-011
Diagram of maximum installation height above the diaphragm seal for
vacuum applications
Endress+Hauser
Cerabar S
Certificates and approvals
CE mark
The device meets the legal requirements of the relevant EC directives.
Endress+Hauser confirms that the device has been successfully tested by applying the CE mark.
Ex approvals
•
•
•
•
•
•
•
ATEX
FM
CSA
NEPSI
IECEx
GOST
also combinations of different approvals
All explosion protection data are given in separate documentation which is available upon request. The Ex
documentation is supplied as standard with all devices approved for use in explosion hazardous areas.
→ See also page 91 ff, sections "Safety Instructions" and "Installation/Control Drawings".
Suitability for hygenic
processes
The Cerabar S is suitable for the employment in hygenic processes.
Overview of permitted process connections from page 5.
Many versions meet the requirements of 3A-Sanitary Standard No. 74.
Endress+Hauser confirms this by attaching the 3A symbol.
!
Note!
The gap-free connections can be cleaned without residue using the usual
cleaning methods.
TYPE EL
October 2007
Marine certificate
• GL
• ABS
Overspill protection
WHG
CRN approvals
Some device versions have CRN approval. For a CRN-approved device, a CRN-approved process connection
(→ see page 78, feature 70 "Process connection") has to be ordered with a CSA approval (→ see page 77,
feature 10 "Approval"). PMP75 devices with capillary are not CRN-approved. These devices are fitted with a
separate plate bearing the registration number 0F10525.5C.
Pressure Equipment Directive
(PED)
The devices PMC71, PMP71 and PMP75 correspond to Article 3 (3) of the EC directive 97/23/EC (Pressure
Equipment Directive) and has been designed and manufactured according to good engineering practice.
Additionally applies:
– PMP71 with threaded connection and internal diaphragm PN > 200 as well as
oval flange adapter PN > 200:
Suitable for stable gases in group 1, category I
– PMP75 with pipe diaphragm seal ≥ 1.5"/PN 40:
Suitable for stable gases in group 1, category II
– PMP75 with separator PN > 200:
Suitable for stable gases in group 1, category 1
– PMP75 with threaded connection PN > 200
Endress+Hauser
75
Cerabar S
Standards and guidelines
DIN EN 60770 (IEC 60770):
Transmitters for use in industrial-process control systems
Part 1: Methods for inspection and routine testing
DIN 16086:
Electrical pressure measuring instruments, pressure sensors, pressure transmitters, pressure measuring
instruments, concepts, specifications in data sheets
EN 61326-X:
EMC product family standard for electrical equipment for measurement, control and laboratory use.
76
Endress+Hauser
Cerabar S
Ordering information
PMC71
This overview does not mark options which are mutually exclusive.
10
A
1
6
2
8
3
5
7
S
T
R
U
V
G
H
I
➀
–
+
➁
E
20
➂
2
PC
HART
1
2
250002271-–
R
FIELD COMMUNICATION PROTOCOL
HW-Version:
SW-Version:
For non-hazardous areas
ATEX II 1/2 G EEx ia IIC T6
ATEX II 1/2 G EEx ia IIC T6, overspill protection WHG
ATEX II 1/2 D EEx ia IIC T6
ATEX II 1 GD EEx ia IIC T6
ATEX II 1/2 GD EEx ia IIC T6
ATEX II 2 G EEx d[ia] IIC T6
ATEX II 3 G EEx nA II T6
FM IS, Class I, II, III Division 1, Groups A – G; NI Class I Division 2, Groups A – D; AEx ia
FM XP, Class I Division 1, Groups A – D; AEx d
FM NI, Class I, Division 2, Groups A – D
CSA IS, Class I, II, III Division 1, Groups A – G; Class I Division 2, Groups A – D, Ex ia
CSA XP, Class I Division 1, Groups B – D; Ex d
NEPSI Ex d[ia] IIC T4/T6
NEPSI Ex ia IIC T6
IECEx Zone 0/1 Ex ia IIC T6
Output; Operation:
A
B
C
M
N
O
P
Q
R
➃
1
Approval:
30
T14
4...20 mA HART, operation outside, LCD (→ see Fig. ➀, o)
4...20 mA HART, operation inside, LCD (→ see Fig. ➀, p)
4...20 mA HART, operation inside (→ see Fig. p)
PROFIBUS PA, operation outside, LCD (→ see Fig. ➀, o)
PROFIBUS PA, operation inside, LCD (→ see Fig. ➀, p)
PROFIBUS PA, operation inside (→ see Fig. p)
FOUNDATION Fieldbus, operation outside, LCD (→ see Fig. n, p)
FOUNDATION Fieldbus, operation inside, LCD (→ see Fig. n, p)
FOUNDATION Fieldbus, operation inside (→ see Fig. p)
Housing; Cable entry; Protection:
A
B
C
D
E
F
1
2
3
4
5
6
P
S
T
U
V
T17
PMC71
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 6P, Gland M 20x1,5
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 6P, Thread G 1/2
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 6P, Thread 1/2 NPT
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 6P, M 12x1 PA plug
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 6P, 7/8" FF plug
Aluminium T14 housing, optional display on the side, IP 65/NEMA 4X, Hand 7D plug 90°
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 6P, Gland M 20x1,5
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 6P, Thread G 1/2
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 6P, Thread 1/2 NPT
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 6P, M 12x1 PA plug
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 6P, 7/8" FF plug
AISI 316L T14 housing, optional display on the side, IP 65/NEMA 4X, Hand 7D plug 90°
AISI 316L T17 housing, optional display on the side, IP 66/68/NEMA 6P, Gland M 20x1,5
AISI 316L T17 housing, optional display on the side, IP 66/68/NEMA 6P, Thread G 1/2
AISI 316L T17 housing, optional display on the side, IP 66/68/NEMA 6P, Thread 1/2 NPT
AISI 316L T17 housing, optional display on the side, IP 66/68/NEMA 6P, M 12x1 PA plug
AISI 316L T17 housing, optional display on the side, IP 66/68/NEMA 6P, 7/8" FF plug
order code
→ For continuation of ordering information for PMC71, see the following page.
Endress+Hauser
77
Cerabar S
PMC71 (continued)
40
Sensor range; Sensor overload limit (= OPL):
Sensors for gauge pressure
Measurement limits: –100 % (–1 bar)...+100 % of sensor nominal range
Sensor nominal value (URL)
OPL (Over pressure limit)
1C
100 mbar/10 kPa/1.5 psi g
4 bar/400 kPa/60 psi g
1E
250 mbar/25 kPa/3.75 psi g
5 bar/500 kPa/75 psi g
1F
400 mbar/40 kPa/6 psi g
8 bar/800 kPa/120 psi g
1H
1 bar/100 kPa/15 psi g
10 bar/1 MPa/150 psi g
1K
2 bar/200 kPa/30 psi g
18 bar/1,8 MPa/270 psi g
1M 4 bar/400 kPa/60 psi g
25 bar/2,5 MPa/375 psi g
1P
10 bar/1 MPa/150 psi g
40 bar/4 MPa/600 psi g
1S
40 bar/4 MPa/600 psi g
60 bar/6 MPa/900 psi g
Sensors for absolute pressure
Sensor nominal value (URL)
OPL (Over pressure limit)
2C
100 mbar/10 kPa/1.5 psi abs
4 bar/400 kPa/60 psi abs
2E
250 mbar/25 kPa/3.75 psi abs
5 bar/500 kPa/75 psi abs
2F
400 mbar/40 kPa/6 psi abs
8 bar/800 kPa/120 psi abs
2H
1 bar/100 kPa/15 psi abs
10 bar/1 MPa/150 psi abs
2K
2 bar/200 kPa/30 psi abs
18 bar/1,8 MPa/270 psi abs
2M 4 bar/400 kPa/60 psi abs
25 bar/2,5 MPa/375 psi abs
2P
10 bar/1 MPa/150 psi abs
40 bar/4 MPa/600 psi abs
2S
40 bar/4 MPa/600 psi abs
60 bar/6 MPa/900 psi abs
50
Calibration; Unit:
1
2
3
4
6
B
C
D
K
L
M
70
Sensor range; mbar/bar
Sensor range; kPa/MPa
Sensor range; mmH2O/mH2O
Sensor range; inH2O/ftH2O
Sensor range; psi
Customised; see additional specification
Factory certificate 5-point; see additional specification
DKD certificate; see additional specification
Platinum; see additional specification
Platinum and factory certificate 5-point; see additional specification
Platinum and DKD certificate; see additional specification
Process connection; Material:
GA
GB
GC
GD
GE
GF
GG
GH
GJ
GK
RA
RB
RC
RD
RE
RF
RG
RH
RJ
RK
GL
RL
GP
GQ
PMC71
Thread, internal diaphragm
Thread ISO 228 G 1/2 A EN 837, AISI 316L (CRN)
Thread ISO 228 G 1/2 A EN 837, Alloy C (CRN)
Thread ISO 228 G 1/2 A EN 837, Monel
Thread ISO 228 G 1/2 A EN 837, PVDF
(max. 15 bar/225 psi, –10...+60°C/+14...+140°F)
Thread ISO 228 G 1/2 A G 1/4 (female), AISI 316L (CRN)
Thread ISO 228 G 1/2 A G 1/4 (female), Alloy C (CRN)
Thread ISO 228 G 1/2 A G 1/4 (female), Monel
Thread ISO 228 G 1/2 A hole 11.4 mm, AISI 316L (CRN)
Thread ISO 228 G 1/2 A hole 11.4 mm, Alloy C (CRN)
Thread ISO 228 G 1/2 A hole 11.4 mm, Monel
Thread ANSI 1/2 MNPT 1/4 FNPT, AISI 316L (CRN)
Thread ANSI 1/2 MNPT 1/4 FNPT, Alloy C (CRN)
Thread ANSI 1/2 MNPT 1/4 FNPT, Monel
Thread ANSI 1/2 MNPT, hole 11.4 mm, AISI 316L (CRN)
Thread ANSI 1/2 MNPT, hole 11.4 mm, Alloy C (CRN)
Thread ANSI 1/2 MNPT, hole 11.4 mm, Monel
Thread ANSI 1/2 MNPT hole 3 mm, PVDF
(max. 15 bar/225 psi, –10...+60°C/+14...+140°F)
Thread ANSI 1/2 FNPT, AISI 316L (CRN)
Thread ANSI 1/2 FNPT, Alloy C (CRN)
Thread ANSI 1/2 FNPT, Monel
Thread JIS B0202 G 1/2 (male), AISI 316L
Thread JIS B0203 R 1/2 (male), AISI 316L
Thread DIN 13 M 20x1.5 EN 837 hole 3 mm, AISI 316L
Thread DIN 13 M 20x1.5 EN 837 hole 3 mm, Alloy C
For continuation "Process connection, Material" see next page.
order code
→ For continuation of ordering information for PMC71, see the following page.
78
Endress+Hauser
Cerabar S
PMC71 (continued)
70
Process connection; Material (continued):
1G
1H
1J
1K
1L
1M
2D
2E
2F
2G
2H
2J
1R
1S
CP
CQ
BR
B3
C3
BS
B4
AE
AQ
AF
JR
A3
AR
AG
JS
A4
AS
AH
JT
AT
KF
KL
KH
MP
MR
TD
TF
TK
TR
80
Thread, flush-mounted diaphragm
Thread ISO 228 G 1 1/2 A, AISI 316L
Thread ISO 228 G 1 1/2 A, Alloy C
Thread ISO 228 G 1 1/2 A, Monel
Thread ISO 228 G 2 A, AISI 316L
Thread ISO 228 G 2 A, Alloy C
Thread ISO 228 G 2 A, Monel
Thread ANSI 1 1/2 MNPT, AISI 316L (CRN)
Thread ANSI 1 1/2 MNPT, Alloy C (CRN)
Thread ANSI 1 1/2 MNPT, Monel (CRN)
Thread ANSI 2 MNPT, AISI 316L (CRN)
Thread ANSI 2 MNPT, Alloy C
Thread ANSI 2 MNPT, Monel
Thread DIN 13 M 44x1.25, AISI 316L
Thread DIN 13 M 44x1.25, Alloy C
EN/DIN flanges, flush-mounted diaphragm
DN 32 PN 10-40 B1, AISI 316L
DN 40 PN 10-40 B1, AISI 316L
DN 50 PN 10-16 A, PVDF (max. 15 bar/150 psi, –10...+60°C/+14...+140°F)
DN 50 PN 10-40 B1, AISI 316L
DN 50 PN 63 B2, AISI 316L
DN 80 PN 10-16 A, PVDF (max. 15 bar/150 psi, –10...+60°C/+14...+140°F)
DN 80 PN 10-40 B1, AISI 316L
ANSI flanges, flush-mounted diaphragm
1 1/2" 150 lbs RF, AISI 316/316L (CRN)
1 1/2" 300 lbs RF, AISI 316/316L (CRN)
2" 150 lbs RF, AISI 316/316L (CRN)
2" 150 lbs RF, AISI 316L with ECTFE-coating
2" 150 lbs RF, PVDF (max. 15 bar/225 psi, –10...+60°C/+14...+140°F)
2" 300 lbs RF, AISI 316/316L (CRN)
3" 150 lbs RF, AISI 316/316L (CRN)
3" 150 lbs RF, AISI 316L with ECTFE-coating
3" 150 lbs RF, PVDF (max. 15 bar/225 psi, –10...+60°C/+14...+140°F)
3" 300 lbs RF, AISI 316/316L (CRN)
4" 150 lbs RF, AISI 316/316L (CRN)
4" 150 lbs RF, AISI 316L with ECTFE-coating
4" 300 lbs RF, AISI 316/316L (CRN)
JIS flanges, flush-mounted diaphragm
10K 50A RF, AISI 316L
10K 80A RF, AISI 316L
10K 100A RF, AISI 316L
Hygienic connections, flush-mounted diaphragm
DIN 11851 DN 40 PN 25, AISI 316L, 3A with HNBR/EPDM seal (CRN)
DIN 11851 DN 50 PN 25, AISI 316L, 3A with HNBR/EPDM seal (CRN)
Tri-Clamp ISO 2852 DN 51 (2"), AISI 316L, 3A with HNBR/EPDM seal (CRN)
Tri-Clamp ISO 2852 DN 76.1 (3"), AISI 316L, 3A with HNBR/EPDM seal (CRN)
DRD DN50 (65 mm), PN 25, AISI 316L, 3A with HNBR/EPDM seal
Varivent type N for tubes DN 40 – DN 162, PN 40, AISI 316L,
3A with HNBR/EPDM seal (CRN)
Seal:
A
B
D
E
F
L
M
1
2
PMC71
FKM Viton
EPDM
Kalrez
Chemraz
NBR/3A: HNBR (FDA)
FKM Viton, cleaned for silicone-free service
Kalrez, cleaned for silicone-free service
FKM Viton, cleaned from oil and greace
FKM Viton, oxygen service
Note application limits pressure/temp.
order code
→ For continuation of ordering information for PMC71, see the following page.
Endress+Hauser
79
Cerabar S
PMC71 (continued)
100
Additional option 1:
A
E
T
B
M
N
S
V
2
3
4
110
not selected
SIL2/IEC 61508 Declaration of conformity
High temperature version
Material test certificate for wetted parts, inspection certificate as per EN 10204 3.1
acc. to specification 52005759
Overvoltage protection
HistoROM/M-DAT
GL (German Lloyd)/ABS marine certificate
Mounting on shut-off valve from above
Test report acc. to EN 10204 2.2
Routine test with certificate, inspection certificate as per EN 10204 3.1
Overpressure test with certificate,
inspection certificate as per EN 10204 3.1
Additional option 2:
A
E
G
T
M
N
S
U
2
3
4
5
PMC71
80
not selected
SIL2/IEC 61508 Declaration of conformity
Separate housing, cable length see additional spec. + mounting bracket,
wall/pipe, 316L
High temperature version
Overvoltage protection
HistoROM/M-DAT
GL (German Lloyd)/ABS marine certificate
Mounting bracket for wall/pipe, AISI 304
Test report acc. to EN 10204 2.2
Routine test with certificate, inspection certificate as per EN 10204 3.1
Overpressure test with certificate, inspection certificate as per EN 10204 3.1
Helium leak test EN 1518 with test certificate,
inspection certificate as per EN 10204 3.1
complete order code
Endress+Hauser
Cerabar S
PMP71
This overview does not mark options which are mutually exclusive.
10
A
1
6
2
4
8
3
5
7
S
T
Q
R
U
V
W
G
H
I
B
C
D
E
F
➀
–
+
➁
E
20
➂
2
PC
HART
1
2
250002271-–
R
FIELD COMMUNICATION PROTOCOL
HW-Version:
SW-Version:
For non-hazardous areas
ATEX II 1/2 G EEx ia IIC T6
ATEX II 1/2 G EEx ia IIC T6, overspill protection WHG
ATEX II 1/2 D
ATEX II 1/3 D
ATEX II 1 GD EEx ia IIC T6
ATEX II 1/2 GD EEx ia IIC T6
ATEX II 2 G EEx d IIC T6
ATEX II 3 G EEx nA II T6
FM IS, Class I, II, III Division 1, Groups A – G; NI Class I Division 2, Groups A – D; AEx ia
FM XP, Class I Division 1, Groups A – D; AEx d
FM DIP, Class II, III Division 1, Groups E – G
FM NI, Class I, Division 2, Groups A – D
CSA IS, Class I, II, III Division 1, Groups A – G; Class I Division 2, Groups A – D, Ex ia
CSA XP, Class I Division 1, Groups B – D; Ex d
CSA Class II, III Division 1, Groups E – G (Dust Ex)
NEPSI Ex d IIC T6
NEPSI Ex ia IIC T6
IECEx Zone 0/1 Ex ia IIC T6
Combined certificates: ATEX II 1/2 G EEx ia IIC T6 + II 2 G EEx d IIC T6
Combined certificates: FM IS and XP Class I Division 1, Groups A – D
Combined certificates: CSA IS and XP Class I Division 1, Groups A – D
Combined certificates: FM/CSA IS and XP Class I Division 1, Groups A – D
Combined certificates:
ATEX II EEx ia / EEx d + FM/CSA IS + XP
ATEX II 1/2G EEx ia IIC T6+
ATEX II 2G EEx d IIC T6+
FM/CSA IS + XP Cl.I Div.1 Gr.A-D
Output; Operation:
A
B
C
M
N
O
P
Q
R
➃
1
Approval:
30
T14
4...20 mA HART, operation outside, LCD (→ see Fig. ➀, o)
4...20 mA HART, operation inside, LCD (→ see Fig. ➀, p)
4...20 mA HART, operation inside (→ see Fig. p)
PROFIBUS PA, operation outside, LCD (→ see Fig. ➀, o)
PROFIBUS PA, operation inside, LCD (→ see Fig. ➀, p)
PROFIBUS PA, operation inside (→ see Fig. p)
FOUNDATION Fieldbus, operation outside, LCD (→ see Fig. n, p)
FOUNDATION Fieldbus, operation inside, LCD (→ see Fig. n, p)
FOUNDATION Fieldbus, operation inside (→ see Fig. p)
Housing; Cable entry; Protection:
A
B
C
D
E
F
1
2
3
4
5
6
R
S
T
U
V
T17
PMP71
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 6P, Gland M 20x1.5
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 6P, Thread G 1/2
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 6P, Thread 1/2 NPT
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 6P, M 12x1 PA plug
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 6P, 7/8" FF plug
Aluminium T14 housing, optional display on the side, IP 65/NEMA 4X, Hand 7D plug 90°
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 6P, Gland M 20x1.5
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 6P, Thread G 1/2
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 6P, Thread 1/2 NPT
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 6P, M 12x1 PA plug
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 6P, 7/8" FF plug
AISI 316L T14 housing, optional display on the side, IP 65/NEMA 4X, Hand 7D plug 90°
AISI 316L T17 housing, optional display on the side, IP 66/68/NEMA 6P, Gland M 20x1.5
AISI 316L T17 housing, optional display on the side, IP 66/68/NEMA 6P, Thread G 1/2
AISI 316L T17 housing, optional display on the side, IP 66/68/NEMA 6P, Thread 1/2 NPT
AISI 316L T17 housing, optional display on the side, IP 66/68/NEMA 6P, M 12x1 PA plug
AISI 316L T17 housing, optional display on the side, IP 66/68/NEMA 6P, 7/8" FF plug
order code
→ For continuation of ordering information for PMP71, see the following page.
Endress+Hauser
81
Cerabar S
PMP71 (continued)
40
Sensor range; Sensor overload limit (= OPL):
Sensors for gauge pressure
Measurement limits: –100 % (–1 bar)...+100 % of sensor nominal range
Sensor nominal value (URL)
OPL (Over pressure limit)
1C
100 mbar/10 kPa/1.5 psi g *
4 bar/400 kPa/60 psi g
1E
250 mbar/25 kPa/3.75 psi g *
4 bar/400 kPa/60 psi g
1F
400 mbar/40 kPa/6 psi g
6 bar/600 kPa/90 psi g
1H
1 bar/100 kPa/15 psi g
10 bar/1 MPa/150 psi g
1K
2 bar/200 kPa/30 psi g
20 bar/2 MPa/300 psi g
1M 4 bar/400 kPa/60 psi g
28 bar/2.8 MPa/420 psi g
1P
10 bar/1 MPa/150 psi g
40 bar/4 MPa/600 psi g
1S
40 bar/4 MPa/600 psi g
160 bar/16 MPa/2400 psi g
1U
100 bar/10 MPa/1500 psi g
400 bar/40 MPa/6000 psi g
1W 400 bar/40 MPa/6000 psi g
600 bar/60 MPa/9000 psi g
1X
700 bar/70 MPa/10500 psi g *
1050 bar/105 MPa/15700 psi g
Sensors for absolute pressure
Sensor nominal value (URL)
OPL (Over pressure limit)
2C
100 mbar/10 kPa/1.5 psi abs *
4 bar/400 kPa/60 psi abs
2E
250 mbar/25 kPa/3.75 psi abs *
4 bar/400 kPa/60 psi abs
2F
400 mbar/40 kPa/6 psi abs
6 bar/600 kPa/90 psi abs
2H
1 bar/100 kPa/15 psi abs
10 bar/1 MPa/150 psi abs
2K
2 bar/200 kPa/30 psi abs
20 bar/2 MPa/300 psi abs
2M 4 bar/400 kPa/60 psi abs
28 bar/2.8 MPa/420 psi abs
2P
10 bar/1 MPa/150 psi abs
40 bar/4 MPa/600 psi abs
2S
40 bar/4 MPa/600 psi abs
160 bar/16 MPa/2400 psi abs
2U
100 bar/10 MPa/1500 psi g
400 bar/40 MPa/6000 psi g
2W 400 bar/40 MPa/6000 psi g
600 bar/60 MPa/9000 psi g
2X
700 bar/70 MPa/10500 psi g *
1050 bar/105 MPa/15700 psi g
50
Calibration; Unit:
1
2
3
4
6
B
C
D
K
L
M
60
Sensor range; mbar/bar
Sensor range; kPa/MPa
Sensor range; mmH2O/mH2O
Sensor range; inH2O/ftH2O
Sensor range; psi
Customised; see additional specification
Factory certificate 5-point; see additional specification
DKD certificate; see additional specification
Platinum; see additional specification
Platinum and factory certificate 5-point; see additional specification
Platinum and DKD certificate; see additional specification
Membrane material:
1
2
6
70
AISI 316L
Alloy C276
AISI 316L with Gold-Rhodium coating
Process connection; Material:
GA
GB
GE
GF
GH
GJ
RA
RB
RD
RE
RH
RJ
GL
RL
PMP71
Thread, internal diaphragm
Thread ISO 228 G 1/2 A EN 837, AISI 316L
Thread ISO 228 G 1/2 A EN 837, Alloy C
Thread ISO 228 G 1/2 A G 1/4 (female), AISI 316L
Thread ISO 228 G 1/2 A G 1/4 (female), Alloy C
Thread ISO 228 G 1/2 A hole 11.4 mm, AISI 316L
Thread ISO 228 G 1/2 A hole 11.4 mm, Alloy C
Thread ANSI 1/2 MNPT 1/4 FNPT, AISI 316L (CRN)
Thread ANSI 1/2 MNPT 1/4 FNPT, Alloy C (CRN)
Thread ANSI 1/2 MNPT hole 11.4 mm, AISI 316L (CRN)
Thread ANSI 1/2 MNPT hole 11.4 mm, Alloy C (CRN)
Thread ANSI 1/2 FNPT, AISI 316L
Thread ANSI 1/2 FNPT, Alloy C
Thread JIS B0202 G 1/2 (male), AISI 316L
Thread JIS B0203 R 1/2 (male), AISI 316L
For continuation "Process connection; Material", see next page.
order code
* in preparation.
→ For continuation of ordering information for PMP71, see the following page.
82
Endress+Hauser
Cerabar S
PMP71 (continued)
70
Process connection; Material (continued):
GP
GQ
1A
1B
1D
1E
1G
1H
1K
1L
2A
2B
2D
2E
2G
2H
1N
1P
1R
1S
CN
CP
CQ
B3
B4
AN
AE
AQ
AF
AR
AG
AS
AH
AT
KA
KF
KL
KH
UR
U1
90
Thread, internal diaphragm (continued)
Thread DIN 13 M 20x1.5 EN 837 hole 11.4 mm, AISI 316L
Thread DIN 13 M 20x1.5 EN 837 hole 11.4 mm, Alloy C
Thread, flush-mounted diaphragm
Thread ISO 228 G 1/2 A, DIN 3852, AISI 316L
Thread ISO 228 G 1/2 A, DIN 3852, Alloy C
Thread ISO 228 G 1 A, AISI 316L
Thread ISO 228 G 1 A, Alloy C
Thread ISO 228 G 1 1/2 A, AISI 316L
Thread ISO 228 G 1 1/2 A, Alloy C
Thread ISO 228 G 2 A, AISI 316L
Thread ISO 228 G 2 A, Alloy C
Thread ANSI 1 MNPT, AISI 316L (CRN)
Thread ANSI 1 MNPT, Alloy C (CRN)
Thread ANSI 1 1/2 MNPT, AISI 316L (CRN)
Thread ANSI 1 1/2 MNPT, Alloy C (CRN)
Thread ANSI 2 MNPT, AISI 316L (CRN)
Thread ANSI 2 MNPT, Alloy C
Thread DIN 16288 M 20x1.5, AISI 316L
Thread DIN 16288 M 20x1.5, Alloy C
Thread DIN 13 M 44x1.25, AISI 316L
Thread DIN 13 M 44x1.25, Alloy C
EN/DIN flanges, flush-mounted diaphragm
DN 25 PN 10-40 B1, AISI 316L
DN 32 PN 10-40 B1, AISI 316L
DN 40 PN 10-40 B1, AISI 316L
DN 50 PN 10-40 B1, AISI 316L
DN 80 PN 10-40 B1, AISI 316L
ANSI flanges, flush-mounted diaphragm
1" 300 lbs RF, AISI 316/316L (CRN)
1 1/2" 150 lbs RF, AISI 316/316L (CRN)
1 1/2" 300 lbs RF, AISI 316/316L (CRN)
2" 150 lbs RF, AISI 316/316L (CRN)
2" 300 lbs RF, AISI 316/316L (CRN)
3" 150 lbs RF, AISI 316/316L (CRN)
3" 300 lbs RF, AISI 316/316L (CRN)
4" 150 lbs RF, AISI 316/316L (CRN)
4" 300 lbs RF, AISI 316/316L (CRN)
JIS flanges, flush-mounted diaphragm
20K 25A RF, AISI 316L
10K 50A RF, AISI 316L
10K 80A RF, AISI 316L
10K 100A RF, AISI 316L
Other
Ovalflange adapter 1/4-18 NPT, mounting: 7/16-20 UNF, AISI 316L (CRN)
Prepared for diaphragm seal mount, AISI 316L (CRN)
Fill fluid:
A
F
K
N
PMP71
Silicone oil fill
Inert oil fill
Inert oil fill, cleaned from oil and greace
Inert oil fill, cleaned for oxygen services
(Note application limits pressure/temperature)
order code
→ For continuation of ordering information for PMP71, see the following page.
Endress+Hauser
83
Cerabar S
PMP71 (continued)
100
Additional option 1:
A
E
B
C
D
M
N
S
2
3
4
110
not selected
SIL2/IEC 61508 Declaration of conformity
Material test certificate for wetted parts, inspection certificate as per
EN 10204 3.1 acc. to specification 52005759
NACE MR0175 (wetted parts)
Material test certificate for wetted parts as per EN 10204 3.1 and NACE
MR0175 material, inspection certificate as per EN 10204 acc. to specification
52010806
Overvoltage protection
HistoROM/M-DAT
GL (German Lloyd)/ABS marine certificate
Test report acc. to EN10204 2.2
Routine test with certificate, inspection certificate as per EN 10204 3.1
Overpressure test with certificate, inspection certificate as per EN 10204 3.1
Additional option 2:
A
E
G
M
N
S
U
2
3
4
5
PMP71
84
not selected
SIL2/IEC 61508 Declaration of conformity
Separate housing, cable length see additional spec. + mounting bracket,
wall/pipe, 316L
Overvoltage protection
HistoROM/M-DAT
GL (German Lloyd)/ABS marine certificate
Mounting bracket for wall/pipe, AISI 304
Test report acc. to EN10204 2.2
Routine test with certificate, inspection certificate as per EN 10204 3.1
Overpressure test with certificate, inspection certificate as per EN 10204
3.1
Helium leak test EN 1528 with test certificate, inspection certificate as
per EN 10204 3.1
complete order code
Endress+Hauser
Cerabar S
PMP75
This overview does not mark options which are mutually exclusive.
10
A
1
6
2
4
8
3
5
7
S
T
Q
R
U
V
W
G
H
I
B
C
D
E
F
➀
–
+
➁
E
20
➂
2
PC
HART
1
2
250002271-–
R
FIELD COMMUNICATION PROTOCOL
HW-Version:
SW-Version:
30
T14
For non-hazardous areas
ATEX II 1/2 G EEx ia IIC T6
ATEX II 1/2 G EEx ia IIC T6, overspill protection WHG
ATEX II 1/2 D
ATEX II 1/3 D
ATEX II 1 GD EEx ia IIC T6
ATEX II 1/2 GD EEx ia IIC T6
ATEX II 2 G EEx d IIC T6
ATEX II 3 G EEx nA II T6
FM IS, Class I, II, III Division 1, Groups A – G; NI Class I Division 2, Groups A – D; AEx ia
FM XP, Class I Division 1, Groups A – D; AEx d
FM DIP, Class II, III Division 1, Groups E – G
FM NI, Class I, Division 2, Groups A – D
CSA IS, Class I, II, III Division 1, Groups A – G; Class I Division 2, Groups A – D, Ex ia
CSA XP, Class I Division 1, Groups B – D; Ex d
CSA Class II, III Division 1, Groups E – G (Dust Ex)
NEPSI Ex d IIC T6
NEPSI Ex ia IIC T6
IECEx Zone 0/1 Ex ia IIC T6
Combined certificates: ATEX II 1/2 G EEx ia IIC T6 + II 2 G EEx d IIC T6
Combined certificates: FM IS and XP Class I Division 1, Groups A – D
Combined certificates: CSA IS and XP Class I Division 1, Groups A – D
Combined certificates: FM/CSA IS and XP Class I Division 1, Groups A – D
Combined certificates:
ATEX II EEx ia / EEx d + FM/CSA IS + XP
ATEX II 1/2G EEx ia IIC T6+
ATEX II 2G EEx d IIC T6+
FM/CSA IS + XP Cl.I Div.1 Gr.A-D
Output; Operation:
A
B
C
M
N
O
P
Q
R
➃
1
Approval:
4...20 mA HART, operation outside, LCD (→ see Fig. ➀, o)
4...20 mA HART, operation inside, LCD (→ see Fig. ➀, p)
4...20 mA HART, operation inside (→ see Fig. p)
PROFIBUS PA, operation outside, LCD (→ see Fig. ➀, o)
PROFIBUS PA, operation inside, LCD (→ see Fig. ➀, p)
PROFIBUS PA, operation inside (→ see Fig. p)
FOUNDATION Fieldbus, operation outside, LCD (→ see Fig. n, p)
FOUNDATION Fieldbus, operation inside, LCD (→ see Fig. n, p)
FOUNDATION Fieldbus, operation inside (→ see Fig. p)
Housing; Cable entry; Protection:
A
B
C
D
E
F
1
2
3
4
5
6
R
S
T
U
V
T17
PMP75
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 6P, Gland M 20x1.5
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 6P, Thread G 1/2
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 6P, Thread 1/2 NPT
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 6P, M 12x1 PA plug,
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 6P, 7/8" FF plug
Aluminium T14 housing, optional display on the side, IP 65/NEMA 4X, Hand 7D plug 90°
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 6P, Gland M 20x1.5
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 6P, Thread G 1/2
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 6P, Thread 1/2 NPT
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 6P, M 12x1 PA plug
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 6P, 7/8" FF plug
AISI 316L T14 housing, optional display on the side, IP 65/NEMA 4X, Hand 7D plug 90°
AISI 316L T17 housing, optional display on the side, IP 66/68/NEMA 6P, Gland M 20x1.5
AISI 316L T17 housing, optional display on the side, IP 66/68/NEMA 6P, Thread G 1/2
AISI 316L T17 housing, optional display on the side, IP 66/68/NEMA 6P, Thread 1/2 NPT
AISI 316L T17 housing, optional display on the side, IP 66/68/NEMA 6P, M 12x1 PA plug
AISI 316L T17 housing, optional display on the side, IP 66/68/NEMA 6P, 7/8" FF plug
order code
→ For continuation of ordering information for PMP75, see the following page.
Endress+Hauser
85
Cerabar S
PMP75 (continued)
40
Sensor range; Sensor overload (= OPL):
1F
1H
1K
1M
1P
1S
1U
1W
2F
2H
2K
2M
2P
2S
2U
2W
50
Sensors for gauge pressure
Measurement limits: –100 % (–1 bar)...+100 % of sensor nominal range
Sensor nominal value (URL)
OPL (Over pressure limit)
400 mbar/40 kPa/6 psi
6 bar/600 kPa/90 psi
1 bar/100 kPa/15 psi
10 bar/1 MPa/150 psi
2 bar/200 kPa/30 psi
20 bar/2 MPa/300 psi
4 bar/400 kPa/60 psi
28 bar/2.8 MPa/420 psi
10 bar/1 MPa/150 psi
40 bar/4 MPa/600 psi
40 bar/4 MPa/600 psi
160 bar/16 MPa/2400 psi
100 bar/10 MPa/1500 psi
400 bar/40 MPa/6000 psi
400 bar/40 MPa/6000 psi
600 bar/60 MPa/9000 psi
Sensors for absolute pressure
Sensor nominal value (URL)
OPL (Over pressure limit)
400 mbar/40 kPa/6 psi abs
6 bar/600 kPa/90 psi abs
1 bar/100 kPa/15 psi abs
10 bar/1 MPa/150 psi abs
2 bar/200 kPa/30 psi abs
20 bar/2 MPa/300 psi abs
4 bar/400 kPa/60 psi abs
28 bar/2.8 MPa/420 psi abs
10 bar/1 MPa/150 psi abs
40 bar/4 MPa/600 psi abs
40 bar/4 MPa/600 psi abs
160 bar/16 MPa/2400 psi abs
100 bar/10 MPa/1500 psi abs
400 bar/40 MPa/6000 psi abs
400 bar/40 MPa/6000 psi abs
600 bar/60 MPa/9000 psi abs
Calibration; Unit:
1
2
3
4
6
B
C
D
60
Sensor range; mbar/bar
Sensor range; kPa/MPa
Sensor range; mmH2O/mH2O
Sensor range; inH2O/ftH2O
Sensor range; psi
Customised; see additional specification
Factory certificate 5-point; see additional specification
DKD calibration: see additional specification
Membrane material:
1
2
3
5
6
7
8
70
AISI 316L
Alloy C276
Monel
Tantal
AISI 316L with Gold-Rhodium coating
AISI 316L with 0.09 mm PTFE foil (not for vacuum applications)
AISI 316L with 0.25 mm PTFE foil (not for vacuum applications, only for non-hazardous areas)
Process connection, Material:
1D
1E
1G
1H
1K
1L
2A
2B
2D
2E
2G
2H
TB
TC
TD
TF
PMP75
Thread, flush-mounted diaphragm
Thread ISO 228 G 1 A, AISI 316L
Thread ISO 228 G 1 A, Alloy C
Thread ISO 228 G 1 1/2 A, AISI 316L
Thread ISO 228 G 1 1/2 A, Alloy C
Thread ISO 228 G 2 A, AISI 316L
Thread ISO 228 G 2 A, Alloy C
Thread ANSI 1 MNPT, AISI 316L
Thread ANSI 1 MNPT, Alloy C (CRN)
Thread ANSI 1 1/2 MNPT, AISI 316L
Thread ANSI 1 1/2 MNPT, Alloy C (CRN)
Thread ANSI 2 MNPT, AISI 316L
Thread ANSI 2 MNPT, Alloy C (CRN)
Clamp connections
Tri-Clamp, ISO 2852 DN 25 (1"), DIN 32676 DN 25, AISI 316L (CRN)
Tri-Clamp, ISO 2852 DN 38 (1 1/2"), DIN 32676 DN 40, AISI 316L (CRN)
Tri-Clamp, ISO 2852 DN 40 – DN 51 (2")/DN 50, AISI 316L (CRN)
Tri-Clamp, ISO 2852 DN 70 – DN 76.1 (3"), AISI 316L (CRN)
order code
→ For continuation of ordering information for PMP75, see the following page.
86
Endress+Hauser
Cerabar S
PMP75 (continued)
70
Process connection; Material (continued):
SB
SC
SD
MR
MS
MT
M3
M4
M5
TG
TH
TI
TL
TM
TN
TP
TQ
TS
TK
TR
CN
DN
EN
E1
CP
CQ
B3
C3
EF
ER
E3
B4
C4
C5
D3
D4
AC
AN
HC
HN
H0
AE
AQ
AF
AR
HF
HR
H3
AG
AS
AH
AT
PMP75
Pipe diaphragm seal, Clamp
Tri-Clamp, ISO 2852 DN 25 (1"), AISI 316L (CRN)
Tri-Clamp, ISO 2852 DN 38 (1 1/2"), AISI 316L, 3.1 +
Pressure test acc. to PED Cat.II (CRN)
Tri-Clamp, ISO 2852 DN 51 (2"), AISI 316L, 3.1 + Pressure test acc. to PED Cat.II
(CRN)
Hygienic connections
DIN 11851 DN 50 PN 25, AISI 316L
DIN 11851 DN 65 PN 25, AISI 316L
DIN 11851 DN 80 PN 25, AISI 316L
DIN 11851 DN 50 PN 25 thread, AISI 316L
DIN 11851 DN 65 PN 25 thread, AISI 316L
DIN 11851 DN 80 PN 25 thread, AISI 316L
SMS 1" PN 25, AISI 316L
SMS 1 1/2" PN 25, AISI 316L
SMS 2" PN 25, AISI 316L
APV-RJT 1" PN 40, AISI 316L
APV-RJT 1 1/2" PN 40, AISI 316L
APV-RJT 2" PN 40, AISI 316L
APV-ISS 1" PN 40, AISI 316L
APV-ISS 1 1/2" PN 40, AISI 316L
APV-ISS 2" PN 40, AISI 316L
DRD DN50 (65 mm) PN 25, AISI 316L
Varivent Type N for pipes DN 40 – DN 162 PN 40, AISI 316L
EN/DIN flanges, flush-mounted diaphragm
DN 25 PN 10-40 B1, AISI 316L
DN 25 PN 63-160 E, AISI 316L
DN 25 PN 250 E, AISI 316L
DN 25 PN 400 E, AISI 316L
DN 32 PN 10-40 B1, AISI 316L
DN 40 PN 10-40 B1, AISI 316L
DN 50 PN 10-40 B1, AISI 316L
DN 50 PN 63 B2, AISI 316L 2
DN 50 PN 100-160 E, AISI 316L
DN 50 PN 250 E, AISI 316L
DN 50 PN 400 E, AISI 316L
DN 80 PN 10-40 B1, AISI 316L
DN 80 PN 100 B2, AISI 316L
DN 100 PN 100 B2, AISI 316L
EN/DIN flanges with extended diaphragm seal, flush-mounted diaphragm
DN 50 PN 10-40 B1, Tubus 50 mm/100 mm/200 mm, AISI 316L
DN 80 PN 10-40 B1, Tubus 50 mm/100 mm/200 mm, AISI 316L
ANSI flanges, flush-mounted diaphragm
1" 150 lbs RF, AISI 316/316L (CRN)
1" 300 lbs RF, AISI 316/316L (CRN)
1" 400/600 lbs RF, AISI 316/316L (CRN)
1" 900/1500 lbs RF, AISI 316/316L (CRN)
1" 2500 lbs RF, AISI 316/316L (CRN)
1 1/2" 150 lbs RF, AISI 316/316L (CRN)
1 1/2" 300 lbs RF, AISI 316/316L (CRN)
2" 150 lbs RF, AISI 316/316L (CRN)
2" 300 lbs RF, AISI 316/316L (CRN)
2" 400/600 lbs RF, AISI 316/316L (CRN)
2" 900/1500 lbs RF, AISI 316/316L (CRN)
2" 2500 lbs RF, AISI 316/316L
3" 150 lbs RF, AISI 316/316L (CRN)
3" 300 lbs RF, AISI 316/316L (CRN)
4" 150 lbs RF, AISI 316/316L (CRN)
4" 300 lbs RF, AISI 316/316L (CRN)
order code
→ For continuation of ordering information for PMP75, see the following page.
Endress+Hauser
87
Cerabar S
PMP75 (continued)
70
Process connection; Material (continued):
J3
J4
J7
J5
J8
KC
KF
KL
KH
UA
UB
UC
UD
UG
UH
90
ANSI flanges with extended diaphragm seal
2" 150 lbs RF, Tubus 2"/4"/6"/8", AISI 316/316L (CRN)
3" 150 lbs RF, Tubus 2"/4"/6"/8", AISI 316/316L (CRN)
3" 300 lbs RF, Tubus 2"/4"/6"/8", AISI 316/316L (CRN)
4" 150 lbs RF, Tubus 2"/4"/6"/8", AISI 316/316L (CRN)
4" 300 lbs RF, Tubus 2"/4"/6"/8", AISI 316/316L (CRN)
JIS flanges, flush-mounted diaphragm
10K 25A RF, AISI 316L
10K 50A RF, AISI 316L
10K 80A RF, AISI 316L
10K 100A RF, AISI 316L
Other
Thread ISO 228 G 1/2 A PN 160, seperator, EN 837, welded, AISI 316L
Thread ANSI 1/2 MNPT PN 160, seperator, welded, AISI 316L (CRN)
Thread ISO 228 G 1/2 B PN 400, seperator, EN 837, threaded, AISI 316L
Thread ANSI 1/2 MNPT PN 400, seperator, threaded, AISI 316L
Thread 1/2 NPT PN 250, seperator, threaded, AISI 316L
Thread 1 NPT PN 250, seperator, threaded, AISI 316L
Fill fluid:
A
B
C
D
F
G
H
K
N
1
2
3
4
5
6
7
8
100
Silicone oil
...m capillary, inert oil
...ft capillary, inert oil
Vegetable oil
Inert oil
High temperature oil, Temp. isolator 100 mm
Silicone oil, Temp. isolator 100 mm
Inert oil, cleaned from oil and greace
Inert oil, cleaned for oxygen services
... m capillary, silicone oil
... ft capillary, silicone oil
... m capillary, high temperature oil
... ft capillary, high temperature oil
... m capillary, vegetable oil
... ft capillary, vegetable oil
... m capillary, Low temperature oil
... ft capillary, Low temperature oil
Additional option 1:
A
E
B
C
D
M
N
S
2
3
4
PMP75
88
not selected
SIL2/IEC 61508 Declaration of conformity
Material test certificate for wetted parts, inspection certificate as per EN
10204 3.1 acc. to specification 52005759
NACE MR0175 (wetted parts)
Material test certificate for wetted parts, inspection certificate as per EN
10204 3.1 and NACE MR0175 material, inspection certificate as per
EN 10204 acc. to specification 52010806
Overvoltage protection
HistoROM/M-DAT
GL (German Lloyd)/ABS marine certificate
Test report acc. to EN 10204 2.2
Routine test with certificate, inspection certificate as per EN 10204 3.1
Overpressure test with certificate, inspection certificate as per EN 10204 3.1
order code
Endress+Hauser
Cerabar S
PMP75 (continued)
110
Additional option 2:
A
E
G
M
N
P
S
U
2
3
4
PMP75
Endress+Hauser
not selected
SIL2/IEC 61508 Declaration of conformity
Separate housing, cable length see additional spec. + mounting bracket,
wall/pipe, 316L
Overvoltage protection
HistoROM/M-DAT
EN10204-3.1 material, Ra < 0.4 μm/15.75 μin (240 grit),
electropolished, (wetted) inspection certificate (in conjunction with
process connection versions "TC", "TD" and "TR")
GL (German Lloyd)/ABS marine certificate
Mounting bracket for wall/pipe, AISI 304
Test report acc. to EN 10204 2.2
Routine test with certificate, inspection certificate as per EN 10204 3.1
Overpressure test with certificate,
inspection certificate as per EN 10204 3.1
complete order code
89
Cerabar S
Documentation
Innovation
• For process pressure, differential pressure, flow and level measurement: IN010P/00/en
Field of Activities
• Pressure measurement, Powerful instruments for process pressure, differential pressure, level and flow:
FA004P/00/en
Technical Information
• Deltabar S: TI382P/00/en
• Deltapilot S: TI416P/00/en
• EMC test basic principles TI241F/00/en
Operating Instructions
4...20 mA HART:
• Cerabar S: BA271P/00/de
• Description of device functions Cerabar S/Deltabar S/Deltapilot S,
Pressure and Differential pressure transmitters:
BA274P/00/en
PROFIBUS PA:
• Cerabar S: BA295P/00/de
• Description of device functions Cerabar S/Deltabar S/Deltapilot S,
Pressure and Differential pressure transmitters:
BA296P/00/en
FOUNDATION Fieldbus:
• Cerabar S: BA302P/00/de
• Description of device functions Cerabar S/Deltabar S, Pressure and Differential pressure transmitters:
BA303P/00/en
Brief operating instructions
• 4...20 mA HART, Cerabar S: KA1019P/00/en
• PROFIBUS PA, Cerabar S: KA1022P/00/en
• FOUNDATION Fieldbus, Cerabar S: KA1025P/00/en
Manual for Functional Safety
(SIL)
• Cerabar S (4...20 mA): SD190P/00/en
90
Endress+Hauser
Cerabar S
Safety Instructions
Endress+Hauser
Certificate/Type of
Protection
Device
Electronic insert
Documentation
ATEX II 1/2 G EEx ia IIC T6
PMC71, PMP71,
PMP75
– 4...20 mA HART,
PROFIBUS PA,
FOUNDATION Fieldbus
– XA244P
ATEX II 1/2 D
PMP71, PMP75
– 4...20 mA HART
– PROFIBUS PA,
FOUNDATION Fieldbus
– XA246P
– XA289P
ATEX II 1/2 D EEx ia IIC
PMC71
– 4...20 mA HART
– PROFIBUS PA,
FOUNDATION Fieldbus
– XA247P
– XA290P
ATEX II 1/3 D
PMP71, PMP75
– 4...20 mA HART
– PROFIBUS PA,
FOUNDATION Fieldbus
– XA248P
– XA291P
ATEX II 2 G EEx d IIC T6
PMP71, PMP75
– 4...20 mA HART,
PROFIBUS PA,
FOUNDATION Fieldbus
– XA249P
ATEX II 2 G EEx d[ia] IIC T6
PMC71
– 4...20 mA HART,
PROFIBUS PA.,
FOUNDATION Fieldbus
– XA250P
ATEX II 3 G EEx nA II T6
PMC71, PMP71,
PMP75
– 4...20 mA HART,
PROFIBUS PA,
FOUNDATION Fieldbus
– XA251P
ATEX II 1/2 GD
EEx ia IIC T6
PMC71, PMP71,
PMP75
– 4...20 mA HART,
PROFIBUS PA,
FOUNDATION Fieldbus
– XA253P
ATEX II 1 GD EEx ia IIC T6
PMC71, PMP71,
PMP75
– 4...20 mA HART,
PROFIBUS PA,
FOUNDATION Fieldbus
– XA276P
ATEX II 1/2 G EEx ia IIC T6
+ ATEX II 2 G EEx d IIC T6
PMP71, PMP75
– 4...20 mA HART,
PROFIBUS PA,
FOUNDATION Fieldbus
– XA252P
ATEX II EEx ia / EEx d +
PMP71, PMP75
FM/CSA IS + XP
ATEX II 1/2G EEx ia IIC T6+
ATEX II 2G EEx d IIC T6+
FM/CSA IS + XP Cl.I Div.1
Gr.A-D
– 4...20 mA HART,
PROFIBUS PA,
FOUNDATION Fieldbus
– in preparation
Certificate/Type of
Protection
Device
Electronic insert
Documentation
IECEx Zone 0/1 Ex ia IIC T6
PMC71, PMP71,
PMP75
– 4...20 mA HART
– XB005P
Certificate/Type of
Protection
Device
Electronic insert
Documentation
NEPSI Ex ia IIC T6
PMC71, PMP71,
PMP75
– 4...20 mA HART,
PROFIBUS PA,
FOUNDATION Fieldbus
– XC003P
NEPSI Ex d IIC T6
PMP71, PMP75
– 4...20 mA HART,
PROFIBUS PA,
FOUNDATION Fieldbus
– XC005P
NEPSI Ex d[ia] IIC T6
PMC71
– 4...20 mA HART,
PROFIBUS PA,
FOUNDATION Fieldbus
– XC005P
91
Cerabar S
Installation/Control Drawings
Overspill protection
92
Certificate/Type of
Protection
Device
Electronic insert
Documentation
FM IS Class I, II, III,
Division 1, Groups A – G;
NI, Class I Division 2,
Groups A – D; AEx ia
PMC71, PMP71,
PMP75
– 4...20 mA HART
– PROFIBUS PA,
FOUNDATION Fieldbus
– ZD147P
– ZD188P
CSA IS Class I, II, III,
Division 1, Groups A – G;
Class I Division 2,
Groups A – G
PMC71, PMP71,
PMP75
– 4...20 mA HART
– PROFIBUS PA,
FOUNDATION Fieldbus
– ZD148P
– ZD189P
FM IS + XP Class I,
Division 1, Groups A – D
PMP71, PMP75
– 4...20 mA HART
– PROFIBUS PA,
FOUNDATION Fieldbus
– ZD187P
– ZD190P
CSA IS + XP Class I,
Division 1, Groups A – D
PMP71, PMP75
– 4...20 mA HART
– PROFIBUS PA,
FOUNDATION Fieldbus
– ZD154P
– ZD191P
FM/CSA IS + XP Class I,
Division 1, Groups A – D
PMP71, PMP75
– 4...20 mA HART
– PROFIBUS PA,
FOUNDATION Fieldbus
– ZD154P + ZD187P
– ZD190P + ZD191P
ATEX II EEx ia / EEx d +
PMP71, PMP75
FM/CSA IS + XP
ATEX II 1/2G EEx ia IIC T6+
ATEX II 2G EEx d IIC T6+
FM/CSA IS + XP Cl.I Div.1
Gr.A-D
– 4...20 mA HART,
PROFIBUS PA,
FOUNDATION Fieldbus
– in preparation
• WHG: ZE260P/00/de
Endress+Hauser
Cerabar S
Endress+Hauser
93
Cerabar S
94
Endress+Hauser
Cerabar S
Endress+Hauser
95
Cerabar S
Instruments International
Endress+Hauser
Instruments International AG
Kaegenstrasse 2
4153 Reinach
Switzerland
Tel. +41 61 715 81 00
Fax +41 61 715 25 00
www.endress.com
info@ii.endress.com
TI383P/00/en/12.07